Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
64 MARLBOROUGH RD - BUILDING INSPECTION (2)
NThe Commonwealth of Massachusetts 1�`b CITY OF ' Board of Building Regulations and Standards MassachusettsState Building Code,780 CMR SALEM „^ Revised Mar 2011 Building Permit Application To Construct, Repair,Renovate Or Demolish a ` One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applied: Building Official(Print Name) signature Dat SECTION 1:SITE INFORMATION �� LI Property Addreis: O As ssors Map&Parcel Numbers 1.1 Is this an accepted street?yes_K no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(11) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check ifyes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 o"per'ogerr Leger Salem MA 01979 Name(Print) City,State,ZIP 64 Marlborough Rd 9787895785 Legerm@comcast.net No.and Street "Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Constructi Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition ❑ 1 Accessory Bldg.❑ 1 Number of Units_ Other ❑ Specity: Brief es ription of Proposed Work': ' SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Material 1. Building $ 1 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical l�t�S (Z Standard City/Town Application Fee ❑Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) otal All Fees:$ eck No. Check Amount: Cash Amount:_ 6.Total Project Cost: 0 Paid in Full 0 Outstanding Balance Due: SECTIONS: CONSTRUCTION SERVICES struction Supervisor License(CSL) 1p) w& t U License Number Expiration DateDate N caf p I cr �� List CSL Type(see below) v Id (f,(t Type Description No.atpi$lrcgl- ��' � F AA r, U Unrestricted(Buildingsu to 35.000 cu.ft.) city/Town,J^ ca'lee,,,ZIP A kV' R Restricted I&2 Famil Dwelling M Masonry RC Roofing Covering WS Window and Siding S, CC ' 1 `n f SF Solid Fuel Burning Appliances OO, , �t�-( Vemoft %gt&oyt( LQll I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement. ( •Contractor(HIC) 7b I 'tj SC HIC Reeggistration Number Expiralionn Date HIC Company Nan%IIC Rqgistrunt NFol am t� No.and Street , ( Rll� 1 1 ___ �u'�•�YTCYt3���)yl ���Ctf��� Email address City/Town,State,ZIP 1 1 �� Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .........it' No............❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize )'V) 90 hr to act on my behalf,in all matters relative to work authorized by this building permit application. Roger Leger „� 11/16/16 Print Owner's Name(Electronic Signature) Date SECTION 7b:OW NERI OR AUTHORIZED AGENT DECLARATION By entering my name below,1 hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print O er s�or AuthorizecTAgent' Name(Electronic Signature) Date NOTES: t. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass;gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dpss 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basementlattics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system - Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts t v:)-• 1��,*Vorkers' Department of IndustrialAccidents 1 Congress Street,Suite 100 Boston, MA 02114-2017 , www.mass govl Compensation Insurance Affidavit:Builders/Contractors/Electricianamumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leef slv Name(Business/Organirationlindividua0:Itivint Solar Developer LLC Address:1800 W Ashton Blvd City/State/Zip:Lehi, UT 84043 Phone#:855-877-2974 An you an employer?Check the appropriate boa: Type of project(required): I.�r I am a employer with 254 employees(full andior parr-time).• 7. New construction 2.F1 I am a sole proprietor ur partnership and have no employees working for me in g, ❑Remodeling any capacity.[No workers'comp,insurance required.] 3.E]1 am a homeowner doing all work myself.[No workers'comp.insurance required.]' 9. ❑Demolition 4.E]lamahomeowner and will be hiring contractors to conduct all work on my proper?. twill 10❑Building addition ensure that all contractors either have workers'compcmalion insurance or are sole I L[]Electrical repairs or additions Proprietors with on employees. 12.❑Plumbing repairs or additions i❑I am a general connector and I have hired the sub-contractors listed on the attached sheet. (3.�ROof repairs These.mbcommclors have employee and have workers'comp.insurance) 6.Q We are a corporation and its officers have exercised their right of exemption per MGL ce 14.❑Other 152,§I(4),and we have no employees.[No workers'comp.insurance required.] .Any applicant that cheeks box#I most also fill out the section below showing their workers'vargtemation policy infomslion. t homeowners who submit this affrdawl indicating they me doing all work and then hie outside contractors most submit a new affidavit indicating such. :Contractors thin check this box must attached an additional sheet showing the name of the sub-contractors and soh whether or not them entities have employees. If the sub-contractors have employees,they must provide their worker]comp policy number. l am an employer that iv providing workers'compensation insurance for my employees. Below is the polity and job site information. Insurance Company Name:Marsh USA Inc Policy#or Self-ins.Lic.#::WCC500t9.601302 Expiration Date:t 1/01/20,177 p n n Job Site Address: 1 M r � QO City/State/Zip: �, X \ 1\!1`^V7I[, Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). 1 Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may he forwarded to the Office of Investigations of the DIA for insurance coverage verification. . /do hereby cerdfy under th and penahies of perfirry that the information provided above is true and correct. Sienaluln: �7 //��2 11 '' —�'r_ Date: L _ 1 l 11� 1\ li/✓1 Phone#: tgSS " W:R— "1 �I `1 Official use only. Do not write in this area,to be completed by city or town official. City or Town: PermittLicense# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Office of Consumer Affairs ed( Business Regulation 10 Park Plaza- Suite 5170 Boston, Massachusetts 0211.6 Home Improvement Contractor Registration ReptetMtlone 170,848 Type; .Supplement Curd VIV.INT SOLAR DEVELOPER LLC. Expiration: resrzoill KYLE GREENE — — —»- 3301 N THANKSGIVING WAY SUITE 500 ------- __ LEHI, UT 84043 tlpddtcAddrescdnd return derd.114uk Bandon for dsnnya. WAi a�M' D Addtt# LT Renewal'.. Empleym at Lort Cadd M ssachusetts - Geo rtment of Public Safety a board 00301dinn Regulations and Standards i '.icense: CS-108068 � KYLE GREENE p`� Jv. 1 44 MAIN STREET North Reading Mil 0ti4t ; ✓t �•' ♦�' Expiration • Comnifts s ner 01 4/2018 y�ya�c���www �j �J�r RESIDENTIAL SOLAR POWER PURCHASE AGREEMENT V Y V Y Y Y eSo I a r Customer Name and Contact Information: Transaction Date Name(s) Roger Leger Service No.2016-11-02 Installation Location Address 64 Marlborough Rd Approximate Start and 64 Marlborough Rd Salem MA 01970 Completion Date Salem 2017-05-01 Home Phone 97$7446232 MA 01970 Cell Phone 9787446232 E-Mail legerm@comcast.net + We will design,install, maintain,repair, + We will not place a lien on Your Property. Our Promises monitor,and insure the System at no additional cost to You. + You are free to cancel this Agreement any time prior to Our commencement of + We warranty all of Our work,and that Our installation work at Your Property. roof penetrations will be watertight,for the initial 20 year term. + The Energy Price includes a$5 monthly discount for paying by automatic debit + Your Energy Price will not increase by more from Your bank account. than 2.9%per year. + You will not be responsible for any + After five years,if You need to make property tax assessed on the System. Property repairs,We will remove and reinstall the System if You pay Our + We will fix or pay for any damage We may estimated costs. cause to Your Property or belongings. Your Commitment • Pay for the Energy produced by the System. Maintain a broadband internet connection. • Keep Your roof in good condition throughout Continue service with Your Utility for any the Term. energy used above and beyond the System's production. • Respond to Our sales and support teams when scheduling and completing paperwork. At the End of Your Initial Term ' You can renew the Agreement • You can request that We remove the System for asubsequent term; at no additional cost. You can purchase the System;or If You Move • We guarantee You can transfer the • You can relocate the System.to Your Agreement to the new owner,regardless of new home;or credit rating; After the sixth anniversary,You can purchase You can prepay the Agreement; the System. Vivint Solar Developer, LLC(EIN: 80-0756438)is a licensed contractor in each state in which we operate,for information about our contractor licenses please visit www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN &OPT-OUT NOTICE BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: support@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 84043 Phone 877.404.4129 1 Fax 801.765.5758 Copyright @ 2016 Vivint Solar Developer,LLC All Rights Reserved PPA(8/2016,v3.2.2)1 Pagel SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. INCORPORATED DOCUMENTS. These documents G. You have the right to require Us to have a are incorporated into this Agreement and apply to the performance and payment bond. relationship between You and Us: (1) Residential Solar H. CUSTOMER'S RIGHT TO CANCEL. YOU MAY Power Purchase Agreement, (2) Exhibit A: Notice of CANCEL THIS CONTRACT AT ANY TIME BEFORE THE Cancellation, (3) Exhibit B: State Notices and LATER OF: (1) MIDNIGHT OF THE THIRD (3RD) Disclosures, (4) Exhibit C: Certificates of Insurance, BUSINESS DAY AFTER THE TRANSACTION DATE, OR and (5) Customer Packet. (11) THE START OF INSTALLATION OF THE SYSTEM OR B. WE HAVE NOT GUARANTEED, PROMISED OR ANY OTHER WORK WE PERFORM ON YOUR OTHERWISE REPRESENTED ANY REDUCTION IN PROPERTY. IF YOU WISH TO CANCEL THIS CONTRACT, ELECTRICITY COSTS IN RELATION TO THE SYSTEM YOU MUST EITHER: (1) SEND A SIGNED AND DATED THAT WILL BE INSTALLED ON YOUR PROPERTY. WRITTEN NOTICE OF CANCELLATION BY MAIL, E-MAIL, C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES OR FAX; OR (2) PERSONALLY DELIVER A SIGNED AND UNLAWFULLY OR COMMIT ANY BREACH OF THE DATED WRITTEN NOTICE OF CANCELLATION TO: PEACE TO REMOVE GOODS INSTALLED UNDER THIS VIVINT SOLAR DEVELOPER, LLC, 1800 W ASHTON AGREEMENT. BLVD, LEHI, UT 84043, ATTN: PROCESSING D. DO NOT SIGN THIS AGREEMENT BEFORE YOU DEPARTMENT. IF YOU CANCEL THIS CONTRACT HAVE READ ALL OF ITS PAGES. You acknowledge that WITHIN SUCH PERIOD, YOU ARE ENTITLED TO A FULL You have read and received a legible copy of this REFUND OF YOUR MONEY. REFUNDS MUST BE MADE Agreement, that We have signed the Agreement, and WITHIN 10 DAYS OF OUR RECEIPT OF THE that You have read and received a legible copy of every CANCELLATION NOTICE. SEE THE ATTACHED NOTICE document that We have signed during the OF CANCELLATION FOR AN EXPLANATION OF THIS negotiation. RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO YOU THE "NOTICE OF CANCELLATION". A SALES REPRESENTATIVE. I. Unless You are provided with a longer period in F. DO NOT SIGN THIS AGREEMENT IF THIS Exhibit A,You may not terminate this Agreement after AGREEMENT CONTAINS ANY BLANK SPACES. You are three(3) business days of the Transaction Date. If You entitled to a completely filled in copy of this seek to cancel thereafter, then You will forfeit any Agreement, signed by both You and Us, before any amounts previously paid and You may owe Us the work may be started. Default Payment. VIVINT SOLAR DEVELOPER, LLC CUSTOMER(S): �167 Signature: Signature: v � Printed Name: Serge Didenko Printed Name: Roger Leger Salesperson No.: Date: 2016-11-02 Date: 2016-11-02 Signature: Printed Name: Date: 2016-11-02 Cooyright© 2016 Vlvint Solar Developer, LLC. All Rights Reserved. PPA(812016,v3.2.2)I Page 18 EcolibriumSolar Customer Info Name: Email: Phone: Projectlnfo Identifier: 5316591 Street Address Line 1: Street Address Line 2: City: State: Zip: Country: System Info Module Manufacturer: JA Solar Module Model: JAP6-60-270/4BB Module Quantity: 10 Array Size (DC watts): 2700.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: v.SE3800A-US (240V) Project Design Variables Module Weight: 40.124084 Ibs Module Length: 64.960665 in Module Width: 39.0157691 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 1.5 Exposure Category: B Importance Factor: I Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load- Lateral: 288 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar Plane Calculations (ASCE.7-10): North East Roof Roof Shape: Edge and Corner Dimension: 3.2672039163388426 ft Attachment Type: Stagger Attachments: Yes Average Roof Height: 30.0 ft Include Snow Guards:Yes Least Horizontal Dimension: 32.6720391633884 ft Include North Row Extensions: No Roof Slope: 22.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 1.0 1.0 1.0 Roof Snow Load 26.9 26.9 26.9 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 26.9 26.9 26.9 psf Downslope: Load Combination 3 10.2 10.2 10.2 psf Down: Load Combination 3 25.2 25.2 25.2 psf Down: Load Combination 5 11.7 11.7 11.7 psf Down: Load Combination 6a 26.6 26.6 26.6 psf Up:Load Combination 7 -10.4 -17.9 -27.5 psf Down Max 26.6 26.6 26.6 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 63.6 63.6 62.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.2 21.2 20.9 in - Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 49.3 49.3 48.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in . Max Cantilever from Attachment to Perimeter of PV Array 16.4 16.4 16.2 in ^ ^ FCO|ibriUnBSOlar LayoutSkirt � = Coupling = End Coupling Note: If the total width ofu continuous array exceeds 35ft' break • Clamp array to allow for thermal expansion and contraction. See • End Clamp Installation Guide for details. 0 North Row Extension Warning: PV Modules may need 1obo shifted with respect to roof 10 Row-to-Row Bonding Clip Bonding Jumper trusses 10 comply with maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 10 Weight of Modules: 401 Ibs Weight of Mounting System: 36 Ibs Total Plane Weight: 437 Ibs Total Plane Array Area: 176 ft2 Distributed Weight: 2.48 psf Number of Attachments: 18 Weight per Attachment Point: 24 Ibs Roof Design Variables Design Load- Downward: 918 IV Design Load- Upward: 720 Ibf Design Load- Downslope: 460 Ibf Design Load- Lateral:252 Ibf EcolibriumSolar Bill Of Materials Part Name Quantity ES10260 EcoX Row-to-Row Bonding Clip 1 ES10121 EcoX Coupling Assembly 9 ES10146 EcoX End Coupling 5 ES10103 EcoX Clamp Assembly 10 ES10136 EcoX End Clamp Assembly 8 ES10144 EcoX Junction Box Bracket 1 (Optional) ES10132 EcoX Power Accessory Bracket 10 ES10333 PV Cable Clip 50 ES10334 4 PV Cable Clip 20 ES10195 EcoX Base, Comp Shingle 18 ES10197 EcoX Flashing, Comp Shingle 18 17 o �7 �Il llto solar 1800 W Ashton Blvd. Structural Group Lehi, UT 84043 Jon P. Ward, SE, PE Clint C. Karren, PE Structural Engineering Manager Structural Engineering Manager ion.ward@vivintsolar.com clint.karren@vivintsolar.com November 09,2016 Mr. Dan Rock, Project Manager Vivint Solar 1800 W Ashton Blvd. Lehi, UT 84043 Re: Structural Engineering Services Leger Residence 64 Marlborough.Rd, Salem, MA S-5316591; MA-01 Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a representative from our office under my supervision identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof section is composed of 2x8 dimensional lumber at 16" on center and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 22 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B, Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page I of 2 vivi t. so I a r B. Loading Criteria 8 PSF= Dead Load (roofing/framing) 40 PSF= Ground Snow Load 3 PSF = Dead Load (solar panels/mounting hardware) Total Dead Load= 11 PSF The above values are within acceptable limits of recognized industry standards for $imilar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (www.ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 Y2" thick and mounted 4 1/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of,2 1/2'", is less than the maximum allowable per connection and therefore is adequate. 4. Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four (4) spaces or 64" o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. �AA�, OF Regards, try ti � N P G Jon P. Ward, SE, PE AR MA License No. 52584 NO s2s : o A �FGISTER�� SS/ONAI ECG\ A� ,►►►► V14 Page 2of2 vivant. solar N �kw� sTEMs�E o ENT's) E%ISTING SONP ❑ eOT I o m 4 cisx w 2 rc E ci PV SYSTEM SIZE: ___—_________—_—_—_—_—___—_—___—___—_—_—_—_� EwMxE. o ¢ 2.700 kW DC S . ,o 1P.M,,. n,EE o I j De nIGeT e>I.oFEMeTSn ee .,. eTEeeOXTOELECTnr.L>ExEE O ----------- Q PS TFMEEREETOT�s ,ITEg e. s°°,Erv ,LI ;T,apox:TIE o INFIER.. ® co 0 E wxEe%.,,, TIMING MCONTING qae; TOKE fn I I 1 BO%OFF OOF _ Je Root Type:Gomp Shingle L.L I ❑ I Y Root Section 1 O O zm:u M T, T j 9 0 j O aka Ca ❑ j M 1I1 SHEET m Ni wg Na SHEET NUMBER: PV SYSTEM SITE PLAN O SCALE:3116"=T-O" >. a '1 CLAMP+ATTACHMENT COUPLING CLAMP ASSEMBLY (INCLUDES GLIDER) LEAF SPRING I i I I 5 � mw l GLIDER o MODULE CLAMP+ATTACHMENT E y � m PERMITTED �+ COUPLING CLAMP SPACING J $ STRUT NUT RAFTER ( ECOX BASE SEALING WASHER RAFTER FLASHING COMP SHINGLES I L I ! I f0 L=PORTRAIT I MODULE CLAMP SPACING ( Q 2 2 5/16"x4 1/2" SS LAG SCREW C 8 IL=LANDSCAPE CLAMP SPACING TOROUE=13m2 FT-LBS 1 `MODULES IN PORTRAIT/LANDSPACE py 3.0 NOTTO-LE MOUNT DETAIL- ECOX " 2 WITH METAL FLASHING �3O NOT TO E z MOUNTING PV 3.0 DETAIL CANTILEVER L/3 OR LESS > w 5`' L=MAX 64" y l; COUPLING CLAMP PV MODULES,TYP.MOUNT OF COMP SHINGLE ROOF, / MODULE SHEET N PARALLEL TO ROOF PLANE NAME RAFTER O o p PV ARRAY TYP. ELEVATION SHEET NOT TO E NUMBER'. PV SYSTEM MOUNTING DETAIL N PJ 3.0 NOT TO scn�E a- a Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) t 2 OC System Size 2]00 Tag 4 Description Wire Gauge Nof Conductors/Color Conduit Type Conduit Size ra S AC ys[em Size 38Do 1 PV Wire 10 AWG 2(V+,V-( N/A Free Air N/A-Free Air sa _,Total Module Count 10 1 Bare Copper Ground(EGC/GEC) 6AWG IBARE N/A Free Air N/A-Free Air 2THWN-2 10 AWG 2(1V+,1V-)B/R PVC 1" — re t m t 2 mi�v m a2 THAN-2-Ground 8AWG 1(GRN) PVC 1 et m 3 THWN-2 30 AWG 3(1L3,112,IN)BW PVC 11 3 THAN-2-Ground 8AWG 1(GRN) PVC 1.1 uo W W x N xvngouemmapm 'Type:Trina Solar RSM-25SPD05.08 4THWN-2-Ground 8AWG 1(GRN) LFNC 1" ce count 1g Existing PVConflu er Panel Exisbaglneerter Information: Type:M21S-S02t1-S23 ZC /gt count 18 V O • N Li VISIBLELOCRe E Cpo 'KNIFE NC C!40V JEELT NZFUSED NE UN NEMA30R ap EQUIVALENT Do Par �e S m Solar Edit. 0 SE3810A-U5 Point of Interconnection,Supply Side f wre 'Conforms as PNSI 7➢sa2(A),Conforms to NEC 2014 a op C12.1-2008 j SQUARE D DU222 R8 SQUARE D 0222NR8 ae "' 24OV/60A UNFUSED ZQW60A FUSED NEMA3 NEMA3 OR EQUI VALENT OR EQUIVALENT WITH 25 W WITH ti TH]SY CTERMIMCONS a r TERMINATIONS EtA alN a n IVE — ? f "t on so of 240V/200A SHEET service Panel.Single NAME: Phaee,-0200AMann Disconnect to `E•a8, C_ STRIN.t.0 PV 1 2 2DA ;DOA J �+ q MODULES 3 Try O 8 3 q 0 SHEET NUMBER: MINIMUM GEC SIZE 4 AWGCOPPER ]OPV MODULES PER INVERTER=2ZOO WALL$ VI NIFE'/�C 'KNIFE'ly STC DISCONNECT DISCONNECT IN SI GET OF TAP ~ W •e DC Safety Switch Conductor Calculations Rated for max operating condition ofinverter PV Module Rating @STC -Wire gauge calculated from NEC code 310.15(B)(16)with ambient temperature calculations NEC 690.35 compliant Module Make/Model )AP6-60-220/4BB from NEC 310.15(3)(a). ze c, itt 'opens all ungrounded conductors Max Power-Point Current(Imp) 8.65 Amps For"On Roof'conductors we use the 90'C column ampaciry,0.5"-3.5"off-the-roof temperature — mm Max Power-Point Voltage(Vmp) 31.23 Volts adjustment from 310.15(8)(3)(c),and raceway fill adjustments from 310.15(B)(16). o f n Optimizer Solar Edge P300 For"Off Roof'Conductors we use the)5'C column ampaciry,or the 90'C column ampaciry with us DC Input Power 300 Watts Open CircuitVoltage(Voc) 38.48 Volts E 'o Short-Circuit Current(Isc) 426 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. la la H a DC Max Input Voltage 48 Volts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous Max Series Fuse(OCPD) 15 Amps o$ 2t DC Max Input Current 12.5 Amps duty upra[ed putpuKurten[. Nom.Maximum Power at STf(Pmax) 2J0 Watts DC Max String Rating Current 15 Amps Calculation Example-WireDuty Rating Output Cu renAmbient Temperature Adjustment x Conduit Fill Max String Rating 5250 Watts Maximum System Voltage DC 113V(UL) Adjustment>=Continuous Duty Output Current Inverter Make/Model SE3800A IA Voc Temperature Coefficient -0.33 %/C (On Roof,Tag 2):10gaugewire mtedfor40A, 40Ax0]6xl(2Ccnductom)=30.4A>=18.75 CEC Efficiency 98 % A AC Operating Voltage 240 Volts PV Module Rating @STC (Off Roof,Tag 3):10gaugewim ratedfor35 A, 35A>=19.29A L ' Continuous Max Output Current 16 Amps Module Make/Model Trina Solar TSM-255 PD05.08 DC Maximum Input Current 13 Amps Max Power Point Current(Imp) 8.32 Amps Short Circuit Current 17.5 Amps Max Power-Point Voltage(Vmp) 30.5 Volts Max Out ut Fault Current ll.5 q/20ms Open-Circuit Voltage(Voc) 38.1 Volts Short-Circuit Current(Ise) 8.88 Amps Max Series Fuse(OCPD) 15 Amps Hour.Maximum Power at STC(Pmax) 255 Watts - MaximumSystemVoltage 1000 V(IEC)/600 V(UL) Voc Temperature Coefficient -0.32 %/C 13 Inverter Make/Model MS-602LL-522-ZC Max DC Volt Rating 45 Volts Max Power at40C 2 Watts ACOutput Current According to NEC 690.8(B)(1) 15.83 Amps NominalAC Voltage 240 40 Volts Nominal AC Voltage 240 Volts Max AC Current 0.9 Amps THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOIAR) OCPD Calculations Max OCPD Rating 20 Amps ROOFTOPCONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE $ Max Number of Panels/Circuit 12 WITH NEC690.8,TABLES 310.15(B)(2)(a),310.15(B)(3)(a), Breakers sized according to continuous duty output current.PV circuit nominal current based off Short Circuit Current 105 Amps 310.15(B)(3)(c),310.15(B)(16),CHAPTER 9 TABLE 4,5,&9. LOCATION inverter continuous output current X(1.25(NEC code 210.19(A)(1)(a)). So is SPECIFIC TEMPERATURE OBTAINED FROM ASHRAE 2013 DATA TABLES. Inverter L SE38W A-US-U Max Output=15,83 A 1,25(NEC code 210.19(A)(1)(a)) z u. =ASH ME 2013- 1979 A<20 A(OCPD) j o > z w Highest Monthly 2%DB Design Temp:325 Celsius system output current w/continuous duty=19J9<20A(System OCPD) Lowest Min.Mean Extreme CB:-23.9 Celsius a a Other Notes 'm^ SHEET •ALL INTERIOR RACEWAYS CARRYING DC CURRENT SHALL BE METALLIC NAME: •All ampaciry calculations are made in compliance with NEC 220.5(B) m ry o m ' 2 a SHEET NUMBER: N W I