8 LOONEY AVE - BUILDING INSPECTION (2) VED The Commonwealth of Massachusetts •��Q� L$EtaVICES V'k�� Board of Building Regulations and Standards ►f °s Massachusetts State Building Code,780 CMR SALEM try 21 Revise¢�daryJJt+1't�Al Building Permit Application To Construct,Repair,Renovate Or Demolish a 1$1! One-or Two-Family Dwelling This Section For Official Use Only n Building Permit Number: Da Applied: i Ok, 14L /5 Building Official(Print Name) Signature V ate SECTION 1:SITE INFORMATION \_ LI Property Address: 6(/` a , 1.2 Assessors Map&Parcel Numbers I.Is Is this an accepted street?yes no�'1j( Map Number Parcel Number - 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone?Check ifyes0 Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 owner arReeara:Ramon Taguiam Salem, MA. 01970 Name(Print) City,State,ZIP 8 Looney Ave 978-744-8977 Rtmotek8@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK=(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ 1 Accessory Bldg.❑ Number of Units_ I Other ❑ Spccily: Brief Description of Proposed Work': n ? v1 CA S ry I SECTION 4: ESThMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ r� �� Check No. Check Amount: Cash Amount:_ 6.Total Project Cost: $ S V ❑Paid in Full ❑Outstanding Balance Due: �. I I SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) ic J 't 1ru p s- S y-w y-T �Pkn License Number Expiration D ep Date Name of CSL Holder U V J - , L�C)\,i List CSL Type(see below) U No.and Street Type Description O .� �.� , t tt U Unrestricted(Buildingsu to 35,000 cu.ft.) �t /W'' R Restricted 1&2 FamilyDwelling CityfT Stale,ZI M Maso nry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) „D , V o V ,nfi `s r HIC Registration Number Expiration Date 29 HIC Corp0�gy;N�N r,.jI1C.Regis n[Name No.an street u UT i�' 1wcy �cA 2,�G q,y ram' Email address Cityrrown,State.ZIP Telephone v� SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........❑ No...........O SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ),as Owner of the subject property,hereby authorize J\V\Y)t SD\C Y- to act on my behalf,in ina. rrs relative to work authorized by this building permit application. R -TA 6Ul Pi I�—A 12/31/14 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. I fir i I L)L Print Owner's or Authorized Agent' a(Ele nic Signature) ate NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.i4ov/oca Information on the Construction Supervisor License can be found at www.mass.Rov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cosr' I I The Commonwealth of 11assachusetds n Department of lndustrialAccidents 7 Office of Investigations = y I Congress Street,Suite 100 <o! Boston, i4 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individuap: Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/State;Zip: Lehi, UT 84043 Phone#:801-377-9111 Are you an employer?Check the appropriate box: Type of project(required): 1.E I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling shipand have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' comp. insurance.# 9. ❑Building addition [No workers' comp. insurance P• required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I LE) Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.] t c. 152, §1(4),and we have no 13.0 Other Solar Installation employees. [No workers' comp.insurance required.] "Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such, tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic.#:WC 509601300 11/1/2015 p,/����� Expiration Date: _^, Job Site Address: �V�r e� CiTy/State/Zip: �2� ,�:Wz Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided arboove is true and correct Sienature: � Date- �lil�/ //Y Phone#: 801-2296459 [[6. icial use only. Do not write in this area,to be completed by city or town official. y or Town: Permit/License # uing Authority(circle one): oard of Health 2.Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector ther ntact Person: Phone 9: i ui ''� CERTIFICATE OF LIABILITY INSURANCE DAIE,Mh1D°"""' 10/31I2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC NAME: 122517TH STREET,SUITE 7300 "a"c°No Eat: ac No: DENVER,CO 80202-5534 no AIL Alm Denver mrMquest@marsh.mm,Fm:212.948.4381 INSURERS AFFORDING COVERAGE NAIC k 462738-STND-GAWUE-14-15 INSURER A:Evanston Insurance Company 35378 INSURED Zurich Amencen Insurance Company 16535 VIVIn($oaf,Inc: INSURER B Mvinl Solar Developer LLC INSURER C:American Zurich Insurance Company 40142 3301 North Thanksgiving Way INSURER D: Suite 500 Lehi,UT 84043 INSURER E: INSURER F COVERAGES CERTIFICATE NUMBER: SEA-002368030-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL UBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE POLICY NUMBER MMIDD/VYYY MMID LIMITS A GENERAL LIABILITY 14PKGWE00274 11/0112014 11/01/2015 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE T RENTED 50 ggg PREMISES Ea occunence $ CLAIMS-MADE M OCCUR MED EXP(Any one person) $ 5,000 X $5,000 Ded.BI&PD PERSONAL B ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY[XI PRO- LOC $ B AUTOMOBILE LIABILITY BAP509601500 11/0112014 11/01/2015 COMBINED SINGLE LIMIT 1,000,000 Eaaccident $ JXX ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS OS BODILY INJURY(Per accidenp $ AUTHIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per acodent A UMBRELLA UAe X OCCUR 14EFXWE00088 11/0112014 11/0112015 EACH OCCURRENCE $ 5,000,000 X EXCESS UIB CLAIMS-MADE AGGREGATE $ 5,000,000 DED RETENTION$ $ C WORKERS COMPENSATION WC509601300 11/0112014 11101/2015 X wC Srnru- oTH- AND EMPLOYERS'LIABILITY B ANY PROPRIETORIPARTNEWEXECUTIVE YIN W0509601400 1110112014 1110112015 EL EACH ACCIDENT $ 110001000 OFFICER/MEMBER EXCLUDED? � NIA (ManEMory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 Ryes,desodbe under 1,000,000 DESCRIPTION OF OPERATIONSbelow EL.DISEASE-POLICY LIMIT $ A Emors&Omissions& 14PKGWE00274 11/01/2014 11/0112015 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(AlMch ACORD 101,Addhional Rem &s Schedule,If mere apace Is required) The Certificate Holder and others as defined in the written agreement am included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- contributory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by wnbon contract Waver of subrogation is applicable where required by wrften contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe ./ ,r.7ir. f,Qcd&e— ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/06) The ACORD name and logo are registered marks of ACORD _ � rr� t(rfyrrvrrr�tarrr��eur✓rirrr � wtcr/.YyGGa�'�/.�iL7/y Office of Consumer Affairs d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. scn 1 e; 20M-05i11 Address Renewal Employment Lost Card 1�t Massachusetts-Department of Public Safety Board of Building Regulations and Standards Construction Supenisor C' _ License: CS-W254 JAMES R SHERMAN 6 Fox Hollow Drife � SAUGUS MA 019M Expiration 08/28/2076 Commissioner i ii r ��j. �� u { solar 3301 North Than6giving Way,Suite 500 Structural Group Lehi,LT84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scoff.wyssling@vivintsolar.com wy gL7a vivintsolar.com December 22,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Taguiam Residence 8 Looney Ave, Salem MA S-4096612 7.14 System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of a prefabricated truss system with all chords constructed of 2 x 4 dimensional lumber at 24" on center. The attic space is unfinished and the photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Hem-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 25 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. eodunt. solar I i Page 2 of 2 B. Loading Criteria 10 PSF= Dead Load roofing/framing 40 PSF=Live Load(ground snow load) 5 PSF=Dead Load solar Panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2012 International Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 I/F thick and mounted 41/2'off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher that 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than the maximum allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts will be adequate with a sufficient factor of safety. 4. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every other roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than two (2) rafter spaces or 48" o/c, whichever is less. 5. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. ZH OF v 1 Scott E.Wyssli PE 0 50 014 MA License No.505 9oF FcISTEPc ESStONAI vivi t. solar 4931 North 300 West,Pmvo,UT 84604 Employer IdcnuEcation No.: 800756438 Massachuserts IC License No.: 1'l0848 u Phone:(87])401-0129 Faro(801)'l65-5'i58 O ' r vivinte solar E-Mail: support.CO. uolar.com AR No.: www.vivintsdlar.com a SIDENTIAL POWER PURCHASE AGREEMENT (( is entered into and between VIVI14T SOLAR DEVELOPER,LLC,a This RESIDENTIAL POWER PURCHASE IAG EEM,7ENT and iherund rsigned Customu(s)("Pau" Youe'),as of the Trwrsaction Date act land,below. Delaware limited liability company(`We",' y�� ��\ Full Name Rimer.w.u,u Full Name Ri.n,m,uan 11 ��Y ' V�a'(� r.,r+"„o^*rrOm o.va QrYtomer(%)' E-Moil: Tdepluntc No.: Pmperp' Su¢¢t Address: (ZQ�Q - .\ddress: City.CounlY,Sn[e,Zip:_�T� nscall,urvice and meinnin a solar pholovolnic system on Your Propertyy,which will include all A. DESIGN AND INSTALLATION. We will design,i the"S r m• as funhtt described in the Customm Packs[end the Work Order that We solar panels,inverters,meters,and other comWnenn(collennely, )'%¢ ) v w late all r quircd WilhpYnor e�omopYeo�uat o¢re WewJll(ijmdesignnsnll and connec[mhe Sy�smms nll¢�e➢i�ucomPli ice wide[all apPl wblc larws;n(')ndt su noes ors. inspections; oat(in)obtain all regmred¢¢rlificauons and peurmyits. In uNer m deo ign a System that meets Vow needs.You ages 0+at We may obnin ay elecmwl usage history than Your electric utilc. i^Y(Be Weuwill l i d You and install)the SystUeiri at no cwi urt W Youof our Utility bills as We may reasonably reyuest Othtt than[he uuvaoon fee dcuribed in ill d en We will interconnect the System with the Utility,and B. ACTIVATION. You agree m pay Us a one-time activatiare fee in the amount ot5 now Iation of the System gonenlly cakes one day and is cauu the System m grnenn energy�••measured in kilowatt hours("kWh")lore�EMrrpp•• You will have rw property interest in the System. anticipated m begin end be subscanh'ally complete between two(2)and six(6 weeks hereaRer. on;and liii)in C. OWNERSHIP OF SYSTEM. We shelLownthe SystEmuOai sole personalpropenY - m. ood conditi D. OPERATIONS AND MAINTENANCE. We will operate and:mninniu rtv seis(smm(i)ae0ur sole cost end exprnse;(ii).' g - matttul wmpliance with all epPliwble laws and pemrin aM the L'uhty's rM _ nrpperly insutm+ceon the System.sFor more F_ INSURANCE. Wesarry com^u'cial ger+eral IiabilitY insurance,worker compensation-.insennce,and' f end to obnin e c of Our certificate of insurmna,pleau visit: www.vrvrnno ar.mrdtnsutana. infom+azion conceminB O"r insurance, oPY 2."1'ERhI YRICE PAY'\tESTS,AND FiN:\NCfA1..DISCLOSl1RES Vou shall Us E0. per kWh((the"Enerp Rice"),plus, plicable tours. ilil.rat hours A. ENERGY PRICE. For all Energy prodyduced by the System,pe ((Pad')) gg f S � '�Ij:�tFY id Yj�SYolu ntrl+e�Cuazmur PabCkc�1'11S grR�M%FNT IStFOR/T11F SAE OF ENERGY BY llS TO YOU[ANDNsT OR THE SALE OF` A SOLAR LNERFI'UEVICE. D. 'I ERN1. 'Phis Agleam�t_shushrll lw d,o first da}lafirr Iha tithe lidlnwi Eate and�have brim uchi"ede lit rthe Sy'le n hasrhYn imhalleJ ynd six aU.N. al�lnf "Tenn''). The"In-5' . ..• v gevcmtinns and ccniiiimlrsprraml o c a y to ove bur arS yreon the ha❑dlity he.c barn a campload+u)received.M1`an tercunncctrd with the NnitS.an (ivl all Inspections v rill x d} m'n + r tl ut the C PAYMENTS- H yyin myy wuh the first urn rah Wlowmg the In N ry "Dal and throughout tire l rm,\ char P fur Ln TS-Zr I'iaaa by the Svsnm m the pr¢eam month Yuualaill make mw+hly panrlaunts to U b)automatic pr))'n cal deduction tom our desngnateJ J ocl rig account car credo'card. 11 is your resp+mand ry I cans re th�t`hero arc aaleyuate fund: - aJ guar equal Iu t'Th r. s n t a ^g 0t i myf Ihrll rsIS25gj m t fail us rook any lu vmm Dun lea(101 la) aft We Eivc' choice oswciatcd a.th this Ag ^rent 1 o all ppaym car[note th ¢ 1101 d)s t d We roue m a lac chart andintema m a.+unnn d rote 1 t pc cat(IO/I�In 1 phcaM1l tees If tor J You written aini",then N'en) is alY rrcJ tat hlct U. .w n1 S ISlhl. D. kF.NEN'AL. At din end 1 th le r You.5, h v.no(i)croon e w d thus Ames t cat n Y to-year b. s li t 'tit tan ..Age n m. ith his Us and enncd Ihu A'rcemapu U+_I Punhau.the S)sem m the end of thu Iarm and Centel 1NbAgo m cat(,he"Ponchos'yr Opt nrr"1 yr Pt )cto he this r Agrecmen\and hove I c Syenn+removed dt no cuA m Von.i'Yor+wrll and m natilw ills m lbe L mrmmg Vtmr elect l' , ,willIM pm iukd to You to dl the term It 1 u Ica the Pnnhar•Opi n th P Im in.P e II M tl d mtnTI eLr+ir mark t vhe t I tire S)t m hard a an mJrlwndvnt ppp s 'rdu uon'Linnl vlY.'r Jph.t.' Imas).t men) u )Eruphr a P > aenpng and willlhe binding. Wa•\will tmndcr owner hip of the tivsam to You ache end of the I Malin all�b lPpWhcn 1. h✓`rsi 11fY tither tin little the Svsmmare+nuiJ�W ecwJl remove the S>>smm Ik:m}'our Pnryry��crty within nincry(ull da>>.tiller the rnJ of the term: O YOU Del NOS M)1'IFY US OF ,•UDk h1 LCI ION 'f(1 CANCLI BN SEe U1NC. A xa'NI tTFN NOIICE TO Iis, fHlN IHIS AOkELMi A WILT, A EANT UNI N'(60 RI?NEW ON.\YLAk/I'(1-\l?Ak kAS11 UKI'16\'Ohl NOTIFI'US IN NRI'l ING OF)OUR ELF" TO( \\C F.L A'1'1 b\SI SI\1'\'Ir't1) DA}'S PkIOk'1'e)'1'IIE END OF'3'IIF.kF.N F.IYAI,TFkN1. - - F CkEUI"1'CHE('E. In nnncction with the cxmninm+'a his AirYour t and.1 avmentan)rtimnom�•rtdndvr+hisn\gran cm is car alit reltorio,g,nc,cs}n11J credit Wring end report trot..rrcdn:epomny o•caries;(ii) rel*'r P'. Pa' - (iiQ diulose this area olhennformation to Our aha[es and actual or pmspecuve IcnJen,lu:encing partie,inramr+,rn carer.,znd ueyuiren. n r c a CREDIT SCORE.PYOUCCAN CHOOSE•TO STOP RECE V[NGL PRESCOREENEED('rOFOFERS OF REI IT FROM NOTICE(SECT ON 029)BELOW BOR MORE I ORMATION(ADOUT PRESCREENED OFFERS. & OPT-OUT in 3.LIMITED W-ARRANyTY y p'u.LIMITEU IINg,n�aIAT10N WA^RRANTf rthe Ti�rm rd�Ve f�rt wrarter cat lhsiaal%I rookop pcnetret ores Wepnsnllshall teratett�ggh¢t s of Ino On of P rt ry t y th .P t r n o ry I f th S .rem. 4n ma t rarer s wavantY is'n addmoa to' not in lieu Cdi ilntio I`W I r( J M1I n. n h t I i aP v i I rot I JOA r ul rn 9 Orc. 0nnd 1 duo li t J n-tall t o ley I'1 i. u l t r P m o f llou it I cnnhgvakc ur uhu,us of I umdale h r n d ynn h n' Wen tv th car Jl. U. . \ n h It. NI:\NI1FA(TL'RF:kS'N',\kk:\N17 F:S. Thr Svnrni s cantor rot doles '+rry minnmr n +u aura s 'err my irl meaty t 111 S o Ipit Ivl Jorine the lira urn i lip yc vet use.the mrrlules', it `kla`.�rrdceruvt autpm rn.II n,nddch reAe h)vmre th rt Iwavny m breakalnn�rnc UvnnFr'I a II'crw.'rW Ibl dvrn thefr'rn O'I OIv t cd ulptr h Sy^ :car unv ..u+n + tIcmrer: rmnry of tenitlgY n- ymina Jclixt.carumnpnn will enforce these wunnnue>to d+c fullest arum Ix':hf ('. I1ISCLAI0IER OF'WARRANTY. FXC'EPT AS SET FORTI OI IN Iky51N""I'll alit`\\S TO l'hNUAIERC'FRIAN'I'AI ILI'I1: OR VOID OR AN\' O'I'HISIt PERSON, Ngila'IIER EXI'(L135S, FI I'NESS POIt ANl` PUftl'OSE OF 'I'llli f:Ul11PMf:NT. INSTALLAI'ION. DESIGN. UPICRAPION, OR iNAIN'I'IiNANI"li MAlik OI THE HEItI".UNUI'.k TALI UOF WNC'IiUN'I.I IIEItFBY GXI'RIiS$LY YDI CLAIM} OURLLL\IL Il NFOR ANYVI1kG\CII OF AN,' AGRI fMl!N'f S\'OUTACKNI�LIEDGB T IA HWG ARF RI LlING ON THIS SE(TION i.Cre\S AIC'ON DIITIOIN AND MA fEIt ONO THE INDUCEN11iNT TO ENTI'R. IN'f0 THIS AGREEMENT'. 1'H ERE ARE NO WARRANT IE$ N'IiICII EXTEND BCYHIe DESCRIPTION OPTHG PACT:HEREOF. 4 RF'MO\'AL OF'I7IE SYSTEM p Yaw stroll not auk¢any Altcmtinns lus Jc OneJ Id nterl¢n It io lwrl'urmanwlor opcnFiun�Ymrmo�rvf.ive U�mriolALehertsVuu�nxifY here I c It, m at no lare is the mmpomq•mmnval tit the 5yysmm car tlmt sou + la"Cnrrnmer-Re4ues/ed Shiirduuvi'1. Ymr agmc tlul:m}}'mpmr car rmpmrcnnvnt n,\bur Property vpl>;'I cam me v ell installed.Ascumpcnsabon tin Ono renavah stYmu>halldhe rc>uireJatn pvyhhc Shu Inwo PuY'^clit has Jc6n alai.mirk�'Isi1 the` ally it to tortin ely' Dollars lSy9y56clmr We rcmm'e the Sysmrn 9 - within thirty(30)days of mmuvld to the evem of au enterge^q'nlT rein•the$Ysant Vnu shall cnntn 1 respond,You caret'y(at Your own ex se contract wid,a licensed sled t at ocu robe cascade m inert b d,c Sysmm m^ecassary m nnaka repmrs required by the cme;g ocy. YOu shall be responsible for any damage,the System that re— from anions taken by Your convacnr. # 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quickly anur d amicably a and We aUgree tour sresalve antioncmDicire uI (as defint ned belo�ihrough bindO� g customer service department is unable to resolve Opr concem,YY. g yy pp ) g arbitration or small dorms court instead of courts ofGgenenII unsdictionA TRIAL. By'SIGNtNG BELOW.Y' AY BRING CLAIMS OU ACKNOWLEDGE AND AST U hTHAT ONLY IN YOU AYOUR INDIV D AIVING THEUAL CAPACITY.AND NOT AS A PLAINTIFF OR'CLASSIMEMBER fN ANY PURPORTED CLASSOR REPRESF.NTAi1VE PROCEEDING. You and We agree to arbitrate all disputes,dorms and conuoverxres ansmg out of or totaling to c.mdun, oou. ..,n.im,. ..I1 rfl'rl i rlt A (rlA1+ .I I• I:. It lln Ile rl l r I 1 _2 lil\III\r, ltllr / III N ♦rll :1 rA + r I r I11 I I ^I I � VI I�1 A lI\I 1 ..I r.nv u+ni. h I n ;v I 1 \ I r r I rllir 11 r r r Irl k`_ rvb• rrl v + r1(• IU V'.O 11III (uI r r '\ I r 1 1 \0 11 r I ..II III . 4�•I+• 1 fl .l ( \I AIMlo,WIAI I Lnl r._1. �„ rll III LI r 1rII+I I+II 11111\1 \I e1 1❑It 1 ,k , kAI i'r, V11IA dAI+I, nhr r.� lll AMA r. .n NrUlll \` k\r r " �I +Ii rin\ , 'I IIV AI vit kli`I\r m Illlt I Pl liA1 fnl Arl lr IXI\UPV\11d \Iln\ i II -I J•n Y'I 1 i..ld J� '' I,... tlll I " r ' 'IrIJ I - 1 � Z IVfla 111 h \ .I 'J / 1 ` •`I'^ 1 1 L pl,. :N, 11 I11 II 111 ^r 5 H r •.rx r.rn' r 1 +.In IpIICS 1111119p(Iti r r J 1 1 p tliq and ICd OI la kill U(YetRl Ilt t Illltt'll')If 411h an,in I lil )I 11( I 1 �1 - f 5 Iµ I Y .d I I /.11hal R f IA \{ I If,any"a rJ u d ro_(1)Youl br ch ,I don 1 uu.menL or(n)Yr ul rfil'1 + g'` I n,ro,cr niw Yl for torins pur I f Ill n I gence or willful miscondmt; prnl'lJed that Your 29.PRESCREEN AND ( II N1.It vnniog uldemllhi' lion uhligations under this Seclinn IN shall nu(apply if "P RE OPT-OUT NOTICE,. THIS the harm or Juwagc that is the basis for sued third punyy claim INP(IRMATI IN y0 occuneJ Mule one of Uur em lovees or a`erns wax al Your('ro r THAT Y"UU M1iGET C8R"FAIN CRIl BRIA. THIS I NDICA NOT p Uli CRGU_II' RCPORT INDICATING and such harm ur d Imde'wn o(�ly au.ed by th- 'n"necheux Gl AR ANTFm IN nr Illlnln I D.... o - ^ '^ -i'ul-Kr1a1161.1 11 I1 yI 11k(u NIRAI 1r. 1nl Llr Aul OA Ill klt llll Ikl v(Ia AII) It191 if II I�I III ru. P.r .I. Ir (toIIIt 61rAI I A AFII r I I Ill If t, Ail'%AIf, I All II11 5 I 1 I, } r. I nl"' +_ r r\sl NII 11 N, I,'if "I ilJ`I it\ I.It I pI I, Csel yr J rl 1 . .rlr II i�rn� r 1r., Ul III I AVI1<IAe,Idrl n I I'll it,I 11 AIII V. }I I kIS+1) 1 I I r+ll A4V Ji 1111vItl 111 ll\AIlrl 1� 1111 I{YIl r� it llrlltrhl ll`a It II I•V rqI I(pl 111 rlAI II�IIII�r4C, pf! n. tqP\It\If\1 NItN WIit Ir r 1 tf y In r, t ll I lAI l h l i1R I_al_•; �r �i t (i)any aspect of the relationship N%cea You and Us,whether based in coat achl eon,a.,a or any other legal theory:(ii)Ih is Agreement or troy other agreement mncernmg the su6)ecl matter hveof (iii) any breach, drl'eult, or trmlmation nC this A reentenl; anJ (iv) the inlerpremtion,validity,or rnliuceahJity ofthis Agreement,including the determination of the scope nr applicability ofthis Section 5(each,e "Dixpulr') Prior In cmm�tencing arbitration,a Parry mull firs)send a wane."Notice of Uisputc"vm certed mail to the other pan}} The Nmmr of Dispulr must Describe the naWre and basis'for the Dispute and the relief sought, II You and We are unable to resolve the Dispute tvuhin Thiny(Jtl) Jayx, then either party may commawc nrbnnttinn. The arFitmnun shall he adminismrcJ by JAMS pursuant to m ' Streamlined Arbitration Rules and Pracetlores(avniluAk or. htlpp://www.)ants:Wr.rnnt/rules-.v'lreumlin,d�uh,s ,ion the"JAMS Rules")and under Thr rules srl fnrllt in This Agreement. The arhitraarr slmll be bound by the leans of this Agreement. No matter the circumstances,the nrbnramr shall not award punitive.s�ccial,exemplary,inJirect.or consequential damages m crther patty. II'Yuu initmte arbitration.You shall he rcsrymslFle to pay 5250. A i auomevs' fees.truvcl eapenses,and other costs ul'the IIbitan ion shall Fc home by Ynu and Us m arcoNance wnh the LAMS Rules mul applicable law. Thr arbitration shalt he cmlducted at a mutually agreeable location near Your Propetty. Judgment on an arbitraton award may c entered w any coon of competent jurisd to ion. Nolhi ag in Ihls Section 5 shall preclude Ynu or We liom seeking proviswnal remedies in:ud ofarhitrntrun Irom u'rnun o1 competent jurisdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE`ARBITRATION OF DISPUTES^PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS I'D HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION * TO NEUTRAL ARBITRATION. RT arc.I�;mu: UWE AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,Ui)the Additional Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. These documents are expressly incorporated into this Agreement and apply to the relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement,that We have signed the Agreement,and that You have read and rceerved a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by bath You and Us,before any work may be started. (E. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PIR�IOR TO THE LATER OF: (I)MIDNIGHT OF THE THIRD TH�L�NOTIBUSINESS E OF CANC DAY ELLATION BELOW OR AN EXE TRANSACTION P AN OR AIT'ION OF H S RIGTHE START OF HT NLATION OF THE SYSTEM. SEE VIVINT SOLAR DEVELO CUSTOMERS): By: By: _� /.�r�,�1,^1C,( L`r/� Printed Name: a` Ce ^ Primed Name: Rjkl- � Tom( y I Title: r Printed Name: Transaction Date: — _ FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REpUIREMENTS, CONTACT THE ASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAZA,SUITE 5170,BOSTON,MA 02116, (617)973-8700 OR 888-283-3757. NOTICE OF CANCELLATION Transaction Date: AR No.: YOU MAY CANCEL THIS TRANSACTION,WITHOUT ANY PENALTY OR OBLIGATION,WITHIN THREE(3)BUSINESS DAYS OF THE ABOVE DATE, OR (IF LATER) UNTIL. THE START OF INSTALLATION OF THE SYSTEM: IF YOU CANCEL,ANY PROPERTY TRADED IN ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE,IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE.SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY((20 DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION,YOU MAY RETAIN OR DISPOSE OF THE GOODS WIT�OUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIT,TO DO SO,THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAR. OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOL& DEVELOPER,LUC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO THE LATER OF: (1)MIDNIGHT OF THE THIRD(J BUSINESS DAY AFTER THE TRANSACTION DATE,OR(11)THE START OF INSTALLATION OF THE SYSTEM. I HEREBY CANCEL THIS TRANSACTION: Date: Customer's Signature: �,. �i �� VDIll IIt N It 11 12"1 AAII I IINMI IUAA IU 1911\I\I .. 1 t i rll r.l i.Ir. 1 .Y, I1111I I'll\111 \ , r i. v i. irr I..rI I I. I. x.0 l•, I •• •• Ir n 1 .Ill. 11 I .:I 1 I ,i r .. nlll• tPA I. I I . 1. I . I Ir f+• 1• 1 r I' IPa tla Je' . I.lau/r P., 1 4 . 1 r..I rlll.• I I .•Ixl:. fly I 14. 11 i1\II\I 1 11 N. IN I. N b Iq. 1..r rqr I . .. 1 •I � 1. 1 I.la IaA Ill\.: uM1r I.0 wF a�1 � r�l 1 I _•Ili..• r. { _ I'I • \ : 1 4. Irr Pu r.. .. \, No..III . I[.�\loll.\I\III.IIIf!\\\ J.1 11. r4fi.nll •I. d, 1' I :.W I n tl ll 910". .rl 4, Iv l I•'I ir)J Ir M1a I�r l a I+In ,•ul i 1- IA I 1 I,1 -1'.r 1 I q{^ 11 7 • k I , -1 lA i 1 u, I .:r l� + ad F I I >•n h, i � i . xin. au,, v`dun a 1 r: l I r u .... - . i. ....r.'n.+r..a•. •-. I,. Inr,.Ily.n ! rc.,xl..I n:a.Io,n wdr m:n liry IIL�\II UI \ir1111 V\I I<b\ I�- r1I ... I+. a.. .,r Ie In C•. II F. '. LI. ..n. n..,a.r IacIIx P.:.\... �b•Jn. r +.. I- .. I ', •r ' '.: 1 , ,el : :. 1'•, 1�6 I Ile '.w 1 i•, i _ I r.I�.a . .,. I «.I r. I •a .J L.w .I .aXr. I + I 1 I. IM1n pv1 1 1 .4 .J •I 1-.:l M1 S I I J .d is uNv .s _ 4 lv d ,y,L' I rJ L •nl. I1a . I • � r Ir.r Ka' IV: +.T as r •• �1 - t -I 1h' F 1�1 It ll 1 I . ...+J ..I,sr. Ip• I 1 ...i41 r A I r•r' :I I I III t 1 ' 1 r r (11 �' r:n ! Irv.11�11(I k I\.IV I�Rk.I� I 1 _. Ir rnr I.. Irl._.irn.ry r .: ,. '. . .I r.,. .. ••4 .:1 1 i I_ A .y I 1 ^Ln I :Jlt 1 •'Fr • l .1•I• J .Iw 11 0\ \I Ih1111'tll Yl V IA1 I• ^ �l vI I el I rr,l •!r• - lir .IX I. D \.4 Ir xl 1 g . \ "al r �•I a 11.11\Itl\141\III Il Utll 111 - I nT✓, .I I.i - l _ \++111i111\I \\II II \,11iiI �l tlll Il.i-I } 'tI\il l�`I lA � A a VAV i All I HI 1 1111 pvvl1It uh \A\ AIt II II VI 1 1 1•=1+.. fif Al + v N N \l IAli G1 Ir11 In>v V1111''1.II I: I A.A+InW tl , unAvk++ yI 'IU IPI i'ii Il llkV + I'1 R�r f.Af IAJI I<1 19l pi 'AIlly Iil 4iI I I IilAI 1 AI Ii� V'11 : li. 1.,' al•.I•:- ,:.e... AIi tl ufi J uA} AA 1A t V �I In V i'lh I`i'I tilfu . ft V n ti AA I I i i t 1 1 N i l it 1. ♦i r, I 1 `.PIP \ II\Htl I I N \IIi Pi\I, Ili 1 +11 Illt It1 UI\II II ,ar y w 1 +il\ \tlfi Vl \ III\Il ':\ Irr I:\I \i iV I'i It file 1 � Xf IIIf VI-il i'\i Vil Al 1f4 tall A':k AI rKI.I IIIAI I'IIiS :: 9 r1 •nl I 'P AAtI It 1 h A t A112 11111t=111 A'1 AII<IN U 11 1 t Ill,lir un'+. »f•...' _ � III11 \Ul ull ell i 'a PIkl lq l•.11'it i\ IIIL : I r 0 1 I lRluty III 1;11 AUIK \I ti 1I1 X1 t III \I\UI 1l1 1 111 \(.\I:\C 1 1 \ (29)Trine Solar TSM-255 PA05.18 MODULES WITH A V INTERCONNECTION POINT, V Enphase M21560-21-L-S2x-ZC MICRO-INVERTER LOCKABLE DISCONNECT SWITCH, -- MOUNTED ON THE BACK OF EACH MODULE ANSI METER LOCATION, ——— ——— — 8 UTILITY METER LOCATION PV SYSTEM SIZE: I T 7.14 kW DC I s -Z�� - NO co Cc co I I � TO I I C O I - U) QI I 0 gmo < y ¢ U I j Z m O I K K z J m W Z O J I ( 2 2 E O SHEET M NAME: w I I ~ J SHEET JUNCTION BOX ATTACHED T 5'OF 1-PVC CONDUIT NUMBER: ARRAY USING ECO HARDWARE TO FROM JUNCTION BOX TO ELEC PANEL KEEP JUNCTION BOX OFF ROOF PV SYSTEM SITE PLAN o __ SCALE: 3/32"= V-0" d I 1 Ho 0 o N1m �o N U ] z G1 mm\ m P� 3 A OA CC m E A(� 3p ac C-y mN N n V YV D � r Co cn m � WE w U) m O X om O ny O m� T I m T tt r D Z c i D i INSTALLER:VIVINT SOLAR 3m ROOF mm INSTALLERNUMBER:IB]].404.4129 ��ys ��y/ c1nJ) arT Taguiam�Residence PV 2-Q s m MA LICENSE:MAHIC 170848 �/ �/ on Y s®I Salem,MA 01970 PLAIM DRAWN BY:Jerry S1 AR 4D96612 I Last Modified:l2J512014 UTILITY ACCOUNT NUMBER:13312-32048 CLAMP 1 MOUNTING sEALINcJI c $ PV3.0 DETAIL WASHERN LOWER (dqw SUPPORT o z mz Em NO PV MODULES, TYP. MOUNT OF COMP SHINGLE ROOF, FLASHINGPARALLEL TO ROOF PLANE CIN CU 5 5/16"9 x 4 1/2" MINIMUM S PV ARRAY TYP. ELEVATION STEEL LAG SCREWS NOT TO SCALE TORQUE=1332 ft-Ibs O CLAMP ATTACHMENT (J) NOT TO SCALE a CLAMP+ ATTACHMENT CANTELEVER L/4 OR LESS c COUPLING A L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. g PERMITTED COUPLING 5 m, a o CLAMP+ CLAMP 7 ATTACHMENT SP C NG CLAMP z m COUPLING PHOTOVOLTAIC MODULE 5 < z W C K z Z m � Z z_ z a 3 SHEET NAME: L=PORTRAIT to CLAMP SPACING t7 M 77 Z Q O ECO 2 p L=LANDSCAPE COMPATIBLE SHEET MODULE PV SYSTEM MOUNTING DETAIL - NUMBER: CLAMP SPACING LMODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE• a Inverter Ratings(Guide Section 4) Q Conduit and Conductor Schedule Inverter MexMMoeel Enphaee M21%0­2L1_S2s-70 Ty Cescnption .1.Gewe polLmtlucmn CanGUM1Trye mana1r sup, MODULE DETAIL Max DC Volt Rating as volLL Fn0sisimaae Fir.-lsrui 12AwG • lip WR-Fl«Ax so AC VOXpe Max Power®rid 215 Wass pmLgp GEc1 e,Gmrx1ppx aAwc t iF,m N, rwa, U 240 VOILL Tina Solar TSM-255 Pi 18 Max AC Cucetn 0191 Amps I T.1 10 Awc a we r SOLAR MODULE Max OCPD Rae,y 20 AMPS 2 T mNNQ-wrd aAwo t PVL CT Q) Max Num 3 ThaiEe,ol Praised—, 1] a. pWe d-1' _ T d. HWX3-Gwnd BPWG 1 Pvc tl-1' R ' NOTES FOR INVERTER CIRCUIT(Guide Section 8 and 9), T •� cow 0¢om 1.)IF UTILITY REQUIRES VISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings @ STC(Guide Section 5) m j _ Enpha5e M215-60-2LLS2x-ZC SWITCH MEET THE REQUIREMENTS? Z MICRO-INVERTER AT YES NO XNA Model MexelMadel Trine Solar T6nt-255 PA05.18 $Er Max Powm-Point Current(Imp) 0.36 Amps �m is EACH MODULE,ATTACHED zo 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Pant Voltage(Vmp) 30.5 Volts w O WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? OpenCmmit Voi(vac) 3].] Volts D U YES NO XNA Shod-Circuit Current(Isc) 8.92 Amps °� ¢ 3.)SIZE PHOTOVOLTAIC POWER SOURCE(Di CONDUCTORS Max Series Fuse(OCPD) 15 Amps -— _ _ BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPO Nominal Maximum Power al BTC(Pmest 1 255 Waup MICROINVERTER CONNECTION _ RATING AT DISCONNECT. Maximum System vales, IMOTECy60otUT c j TO ENGAGE TRUNK CABLE 0)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature CoeRpienl -0.32 9'd°C ^ TO INVERTER OCPD AMPERE RATING(See Guide Section 9). V 5.)TOTAL OF 2 INVERTER OCPDbu.ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix DI, PV CIRCUIT.GOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean supreme NEC 690.54(B)(2)(ap XYES NO Flybulb temperature for ASHRAE location most similar to installatlen location: -19°C 046 BARE CU GROUND IT (GROUNDING ARRAY) Signs(See Guide Section 7) Highestcontinuous ambient temperature based on ASHAEhighest month 2%drybulb temperature for SHRAE location most similar to installation location: 39°C Sign for inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceatl 47°C in the N United States(Palm Springs,CA Is 44A°C).For less than 9 cunent-carrying conductors Solar PV System AC Point of Connection in root-mounted sunlit conduit at least 0.5'above roof and using the outdoor design AC Output Current 25.200000 Amps temperature of 47°C or less(all of United Slates). Nominal AC Voltage ji 24UI Volk a.)12 AWG,90°C conductors are generally acceptable for modules with lac of 7.68 Amps or less when protected by a 12-Amp or smaller fuse. ry THIS PANEL FED BY AND LTIPLE SOiLMU ROES to.)10 AWG,90°C conductors are generally acceptable for modules with lac of 9.6 Amps un (UTILITY AND SOLAR) or less when protectedb a I 5Anpp or smaller fuse. �® NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR 4pc Fa PV CIRCUIT 1: 14 MODULES/PARALLEL ENVOY sox ca as � op s _ ofp 14 • • • O O N to O TPA w> Ms ,E 1.o MURRAv POINT OF DELIVERY w w so m'COMBINER AND INTERCONNECTION tuEL 125A/240V SIEMENS F ;AP ZLWO04NR 60AI240VPoo\FFJ EQUIVALENTUNLN222RORFUSED A3 SHEE� PV CIRCUIT 2: 14 MODULES/PARALLEL FL15 SREC/ANSI EQUIVALENT NAME: OA\'n 0 METER \�O EXISTING 111 14 • • • O O \'A 200 240V/200A Z \\ zdA LOAD-CENTER J Q 1 A a OEQUIVALrNT 0 ✓` • • • S S \ 40A SHEET NUMBER: JUNCTION BOX \\ VISIBLE/LOCKABLE 1 O - 2 \\ 3 'KNIFE'A/C 3 WITH IRREVERSIBLE \ DISCONNECT NEC 2014 Compliant GROUND SPLICE E 1.0 \ E 1.0 E 1.0 LU N O C m D O y O o 9 N 2 z z x O O A m n � �r D III D O n m n zoz A TD Co mI O to A zQ t~ii O T NN Um ;O O0 00 cz mm w� I �� I c3 m 3 z3 x O c A m zm zw INSTALLER:VIVINTSOLAR Taguiam Residence Km DESIGN ''d NSTALLERNUMBER:1.877.404.4129 a/����i S' �(���r BLooney Ave PV 4.0 A ti LOGIC m MA LICENSE:MAHIC 17084E v u u u v Salem,MA 01970 DRAWN BY:Jerry$ AR 4098812 Last Modified:12/S2014 UTILITY ACCOUNT NUMBER:13312-32048 t Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Proiect Information Project Name: Ramon Taguiant Project Address: 8 Looney Ave,Salem MA A. System Description: The array consists of a 7.14 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(28) 255-watt modules and(28)215-watt micro-inverters,mounted on the back of each PV module.The array includes(2) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecofibrium Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Arrav Mounting System: A.System Description: 1.Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B.Mounting System Information: 1.Mounting system is an enginecred product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecollbrlum Solar b.Product Name: Eeorail c.Total Weight of PV Modules and mounting hardware: 1316 Ibs d.Total number of attachment points: 50 e.Weight per attachment point: 26.32 Ibs f.Maximum spacing between attachment points: *See attached engineering talcs g.Total surface area of PV array: 493.08 square feet h.Array pounds per square foot: 2.66 Ibs/square foot i.Distributed wcight of PV array on roof sections: -Roof section 1: (28)modules,(50)attachments 26.32 pounds vivint. solar i j 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 255-PA05.18 28 modules Module Specs Pmax-nominal maximum power at STC - - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.36 amps Isc-rate short circuit current - 8.92 amps B. Inverter (UL 1741 listed) City Enphase M215-60-2LL-S22 28 inverters Inverter Specs . 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit — 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 14 modules/inverters (20)amp breaker PV circuit 2 - 14 modules/inverters (20)amp breaker 2011 NEC Article 705.60(B) vMnt, solar J II D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 12.6 amps Continuous current adjustment factor 125% 2011 NEC Artide 705.60(B) PV circuit continuous current rating 15.75 amps 2.Overcurrent protection device rating PV circuit continuous current rating 15.75 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Artice 705.60(B) Adjusted PV circuit continuous current 22.1 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 17.7 amps Total derated ampacity for PV circuit 17.7 amps Conductors(tag2 on 1-line)must be rated for a minimum of 17.7 amps THWN-2(90°C) #12AWG conductor is rated for 30 amps (Use#12AWG or larger) 2011 NEC Am&705.60(B) 4.Voltage drop(keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.N irco-inverter voltage drop: 0.31% The largest number of micro-inverters in a row in the entire array is 8 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.31 %. 2.AC conductor voltage drop: =I x R x D C 240 x 100 to convert to percent) = (Nominal current of largest circuit)x(Resistance of#12AWG copper)x(Total wire run) = (Circuit 1 nominal current is 12.6 amps)x(0.0020162)x(130�-(240 volts) x(100) 1.37% Total system voltage drop: 1.68% viva. solar I I EcolibriumSolar Customer Info Name: Email Phone: Project Info Identifier: 18976 Street Address Line 1: 8 Looney Ave Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model:TSM-255 PA05.18 Module Quantity: 28 Array Size (DC wafts): 7.14 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight:44.8 Ibs Module Length: 65.5 in Module Width: 39.625 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load-Lateral:288 Ibf EcoX Design Load- Downward: 493 Ibf EcoX Design Load- Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load -Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar 'Plane Calculations (ASCE 7-10): roof 1 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 30.0 ft Include Snow Guards: No Least Horizontal Dimension: 30.0 ft Roof Slope: 25.0 deg Truss Spacing: 24.0 in • Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.82 0.82 0.82 Roof Snow Load 27.6 27.6 27.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASo Load Combinations Description Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 27.6 27.6 27.6 psf Downslope: Load Combination 3 11.6 11.6 11.6 psf Down: Load Combination 3 24.9 24.9 24.9 psf Down: Load Combination 5 11.9 11.9 11.9 psf Down: Load Combination 6a 26.4 26.4 26.4 psf Up: Load Combination 7 -10.3 -17.8 -27.4 psf Down Max 26.4 26.4 26.4 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 63.4 63.4 62.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.1 21.1 20.8 in Spacing.Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 41.0 41.0 41.0 in Max Spacing Between Attachments With Rafter[Truss Spacing of 24.0 in 24.0 24.0 24.0 in Max Cantilever from Attachment to Perimeter of PV Array 13.7 13.7 13.7 in EcolibriumSolar Layout Skirt c Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. j EcolibriurnSolar Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1254 Ibs Weight of Mounting System: 100 Ibs Total System Weight: 1354 Ibs Total Array Area: 505 ft2 Distributed Weight: 2.68 psf Number of Attachments: 50 Weight per Attachment Point: 27 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 50 ECO-001_102 EcoX Coupling Assembly 30 ECO-001_105B EcoX Landscape Skirt Kit 7 ECO-001 105A EcoX Portrait Skirt Kit 0 ECO-001_103 EcoX Composition Attachment Kit 50 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly 1 ECO-001_106 EcoX Bonding Jumper Assembly 4 ECO-001_104 EcoX Inverter Bracket Assembly 28 ECO-001 338 EcoX Connector Bracket 28 I Iv