19 LINCOLN RD - BUILDING INSPECTION (4) yy/-off' r(.f, FILLACIO N.F, LORING "ALT11 TRUST Lol 1 -AREA- 63(,0} S.F. �}rUh + fo poi YS _ DEc.K LoT 2 J � J GARAGE STORY � � DWELL�IJG I ,(- ovERNEAD # 19 LvIRES 5'+ j 49.00, Li NCOL N KoA D REFERENCE: DEED:REC BK. 10165 PG. 262- PLAN: +79 of /147 TO:WARREN FIVE G60Tl SAVINGS 6/IAIK THISPLOTPLAN WASNOTMADEFROM I CERTIFY THAT THE BUILDING(S)SHOWN HEREON AN INSTRUMENT SURVEY AND IS FOR ARE LOCATED ON THE GROUND AS SHOWN AND THAT THEY THE PURPOSES OF THE BANK ONLY. CONFORM TO.THE HORIZONTAL DIMENSIONAL REGULATIONS UNDER NO CIRCUMSTANCES ARE OFFSETS OF THE ZONING BYLAWS OF THE -C1TJ OF SALFM TO BE USED FOR ESTABLISHMENT OF AT THE TIME OF CONSTRUCTION OR ARE PROTECTED UNDER FENCES,WALLS,HEDGES,ETC. GENERAL LAWS CHAPTER 40A SECTION 7. I ALSO CERTIFY THAT THE DWELLING .SHOWN IS NOT y�EP '1Ssy MORTGAGE INSPECTION PLAN LOCATED WITHIN A FLOOD HAZARD ZONE AS <oa GAIL c�� LOCATED AT_ DELINEATED ON THE MAP OF COMMUNITY# 250107. c L 18 UNCOLN ROAD A.�SAAAm M ,EFFECTNE A-S-95 SMITH y SALEM THE FEDERAL EMERGENCY MANAGEMENT AGENCY. q No.35043 . PREPARED FOR IFS�FCLghfcF-O ,�.P¢ PC-TELL . 6, HOt?Z 9v MEGAN D, 14OLTZ LAND SCALE 1-- 7.0' MAACR 12. 200Z NORTH SHORE SURVEY CORP. D REG.PROFESSIONAL LAND SURVEYOR 47 LINDEN STREET.. - SALEM,MA # 1897 W 1 --- ✓/,ePor�tn�rmw�ea�c o�./ maa�u"elld "°��� ,. BOARD OF BUILDING REGULATIONS � Board of Building Regulations and Standards ,. License: CONSTRUCTION SUPERVISOR - HOME IMPROVEMENT CONTRACTOR * Number. CS 063821 Re9kn"tton. 139222 . . Birthdate 09/16/"1959 - Expiratlone. -8124l2007 ExpTiea:09y1612bbll Tr.no: 3154.0 Type; .private Corporation Restricted' 00-: J.L.WARD CONSTRUCTION-.-'INC. JEFFREYL WARD - JEFFREY WARD " 50 GLIDDEN STREET /y 50 GILDDEN ST. 4 BEVERLY, MA 01915 - Commissioner BEVERLY,MA 01915 Administrator __-- (MGL C.112 S.eoy '- 1A-MesoaryonlY 1G-i 6 2 Family Homes Licease or registration Valid for to_ dtvtdd use only FailNUsssaad�wseeas possess 8"mg Code me - - _ before the exptretion date. If fond return to: . Board of au"'Itmg Regulations and Standards is muse for re Ilan of this license. One Ashburton Place Rm 7302 " Bostoo,Ma 02708 n DIG SAFE CALL CENTER: (888)344-7233 without signature Pre-Completion Checklist: Page 4 Homeowner and Contractor will review all work performed to insure that the project has been completed as specified. Any remaining details will be part of this checklist. On completion of these checklist items, the contract will be complete and final payment will be due. Any issue that arises that is not listed in the pre-completion checklist will be treated as warranty work and will not impact the final payment. TOTAL COSTS FOR ALL ITEMS LISTED ABOVE $ 57,180.00. PAYMENT SCHEDULE: WITH ACCEPTANCE OF CONSTRUCTION AGREEMENT $ 9,083.00 PRIOR TO COMMENCEMENT OF DEMOLTION $12,110.00 PRIOR TO COMMENCEMENT OF FRAMING $10,610.00 PRIOR TO COMMENCEMENT OF PLASTERING $12,110.00 PRIOR TO COMMENCEMENT OF CABINET INSTALLATION $10,610.00 AT WALK THROUGH OF PRE-COMPLETION CHECKLIST $ 1,646.00 AT COMPLETION OF CHECK-LIST $ 1,011.00 ACCEPTANCE OF PROPOSAL: The enclosed prices, specifications and conditions are satisfactory and hereby accepted. J.L. Ward and Company are authorized to do the work as specified. Payment will be made as outlined above. This proposal is valid for 15 days from the date specified. Signed and Sealed: �V o Vtid n Agent Signed and Sealed: Date: Signed and Sealed: " 1Y1A— Date: -'All material is guaranteed to be as specified. All work to be completed in accordance to Mass State Building Code. Any alteration or deviation from submitted specifications,involving extra cost will.be executed only upon written orders; and will become an extra charge over and above this estimate.All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workman's Compensation Insurance. REScheck Software Version 4.0.1 Compliance Certificate Project Title: Kitchen Addition/Remodel Report Date:09/27/07 Data filename:C:\Program Files\Check\REScheck\Holtz.rok Energy Code: Massachusetts Energy Code Location: Beverly, Massachusetts Construction Type: 1 or 2 Family,Detached Heating Type: Other(Non-Electric Resistance) Glazing Area Percentage: 10% Heating Degree Days: 6268 Construction Site: Owner/Agent: Designer/Contractor: 19 Lincoln Rd Peter&Meghan Holtz JL Ward Construction, Inc. Salem,MA 01970 19 Lincoln Rd 50 Glidden St Salem,MA 01970 Bevedy,MA 01915 978-921-2752 jeffQ Iwardconstruction.com Gross Cavity Cont - UA Assembiv Area r •••• Ceiling 1:Flat Ceiling or Scissor Truss: 39 30.0 0.0 1 Ceiling 2:Flat Ceiling or Scissor Truss: 162 30.0 0.0 6 Wall 1:Wood Frame, 16"o.c.: 30 13.0 0.0 2 Wall 2:Wood Frame,16"o.c.: 75 13.0 0.0 5 Door:D01:Solid: 18 0.030 1 Wall 3:Wood Frame, 16"o.c.: 30 13.0 0.0 2 Wall 4:Wood Frame, 16"o.c.: 90 13.0 0.0 5 Window:W01:Vinyl Frame,Double Pane with Low-E: 31 0.035 1 Wall 5:Wood Frame,16"o.c.: 157 13.0 0.0 13 Wall 6:Wood Frame,16"o.c.: 58 13.0 0.0 2 Window:W02:Vinyl Frame,Double Pane with Low-E: 12 0.035 0 Door:D02:Solid: 18 0.030 1 Floor 1:All-Wood Joist/Truss,Over Outside Air: 39 30.0 0.0 1 Floor 2:All-Wood Joist/Truss,Over Outside Air: 44 30.0 0.0 1 Floor 3:All-Wood Joist/Truss,Over Unconditioned Space: 49 19.0 0.0 2 Floor 4:Slab-On-Grade:Unheated: 65 1.0 62 Insulation depth:1.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the Massachusetts Energy Code requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. The heating load for this building,and the cooling load if appropriate,has been determined using the applicable Standard Design Conditions found in the Code.The HVAC equipment selected to heat or c I the building shall be no greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Name-Title Si n turV Date /// Kitchen Addition/Remodel Page 1 of 4 L REScheck Software Version 4.0.1 1�j Inspection Checklist C( Date: 09/27/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments:dining addition ❑ Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments:breezeway addition Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: ❑ Wall 2:Wood Frame,16"o.c.,R-13.0 cavity insulation Comments: ❑ Wall 3:Wood Frame,16"o.c.,R-13.0 cavity insulation Comments: ❑ Wall 4:Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: ❑ Wall 5:Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: ❑ Wall 6:Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: Windows: ❑ Window:W01:Vinyl Frame,Double Pane with Low-E,U-factor:0.035 For windows without labeled U-factors,describe features: #Panes—Frame Type Thermal Break? Yes No Comments: ❑ Window:W02:Vinyl Frame,Double Pane with Low-E,1-1-factor:0.035 For windows without labeled U-factors,describe features: #Panes—Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door:D01:Solid,U-factor:0.030 Comments: ❑ Door:D02:Solid,U-factor:0.030 Comments: Floors: ❑ Floor 1:All-Wood Joist/Tmss,Over Outside Air,R-30.0 cavity insulation Comments:dining addition ❑ Floor 2:All-Wood Joist/Truss,Over Outside Air,R-30.0 cavity insulation Comments:existing deck ❑ Floor 3:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation Kitchen Addition/Remodel Page 2 of 4 Comments:rest of the kitchen ❑ Floor 4:Slab-On-Grade:Unheated, 1.0'insulation depth,R-1.0 continuous insulation Comments:entryway Slab insulation extends down from the top of the slab to at least 1.0 ft.OR down to at least the bottom of the slab then horizontally for a total distance of 1.0 ft. Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ When installed in the building envelope,recessed lighting fixtures#meet one of the following requirements: 1 Type IC rated,manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated,in accordance with Standard ASTM E 283,with no more than 2.0 cfm(0,944 Us)air movement from the the conditioned space to the ceiling cavity.The lighting fixture has been tested at 75 PA or 1.57 Ibs/ft2 pressure difference and shall be labeled. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and Floors. Materials Identification: ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Ducts are insulated per Table J4.4.7.1. Duct Construction: ❑ All accessible joints,seams,and connections of supply and return ductwork located outside conditioned space,including stud bays or joist cavities/spaces used to transport air,are sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions.Mesh tape may be omitted where gaps are less than 1/8 inch.Duct tape is not permitted. ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or Floor is provided. Heating and Cooling Equipment Sizing: ❑ Rated output capacity of the heating/ceoling system is not greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 120 degrees F or chilled Fluids below 55 degrees F are insulated to the levels in Table 2. Kitchen Addition/Remodel Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure(femperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Kitchen Addition/Remodel - Page 4 of 4 L10q C4X 557 3 APPROVED By T*IE 'WPJ=CJ-on PFW13 TPA PERMIT BVNG GRANTED CITY OF SALEM Date as-j�y it r Location of n Is Property Located in Building Icl /—i.e.-t.. c� the Historic District? Yes_,No Is Property Located In Yes_No V the conservation Area? BUILDING PERMIT APPLICATION FOR: Permit to: (Circle whichever apply) Roof, Reroof, Install Siding, Construct Deck, Shed, Poo, Repair/Replace, Other: PLEASE FILL OUT LEGIBLY &COMPLETELY TO AVOID DELAYS IN PROCESSING TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit to build according to the following specifications: Owners Dame ,4' _ Address & Phone " 0 /"► 7 y� 7Yl D Archhect's Name Address & Phone Mechanics Name Address & Phone SOLI Sri ols/S What is the purpose of building? Matedel of building? \j oo -t It a dwelling,for how many families? 7 �5 Asbestos? will building conform to law? r4 City License>< N �' state License x Estimated St ��. y Bose improvement Lie.3� y • I 1licant 4SIN*EDNDERL THE PENALTY OF PERJURY DESCRIPTION OF WORK TO BE DONE L 3 e ^ octo P�G65 ciej MAIL PERMIT TO: Jdw, CG( 1. (41a) No. APPLICATION FOR PERMIT TO LOCATION �S Cc/7 Lg� PERMIT GRANTED 31d—S o� 215 AP OV�D i SPECT_ OF BUILDINGS 44