Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11 LARKIN LN - BLDG 14-1504
� q � c,k174� RECEIVE' ul _ 150 INSPECTIONAL. SERVICES The Commonwealth of Massachusetts 1114 SEP IY� }y Board of Building Regulations and Standards Massachusetts State BuildingCode 780 CMR SALEM } aF•' , Revised Mar201l Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Dat pp ied: /9 / Building Official(Print Name) Signature Date SECTION l:SITE INFORMATION 1.1 P6oper Address: 1.2 Assessors Map R:Parcel Numbers 1.1 a 11s Lthis an accepted street?yes X no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq fl) Frontage(ft) 1.5 Building Setbacks(R) Front Yard Side Yards Rear Yard Reyuired Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Check ifyesO Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Rec d: c— I e M Dorothy Malewicki 7Gt Name(Print) City,State,ZIP 11 Larkin Lane 978-745-1149 Grammydottie@verizon.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction X I Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ 1 Alteration(,) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Description of Proposed Work: Xlrn Phtrl'DV f) 1-EQIG Sokcur- Sys-tt°rvLS SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Cosis: ) Official Use Only Labor and Materials I.Building I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ �� ❑Standard City/'fown Application Fee 2kQ ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical.(HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ 6.Total Project Cost: $ CC Check No. Check Amount: Cash Amount: a, _ �a s� 13 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 -Construction Supervisor License(CSL) �1U.'Me f'S e-rfy�CLYI 6caS- case Nuu 4 Number Expirationton ) Name of CSL Holder 21 �—kci to S V r -1 List CSI.l'ype(see below) U No.and Street A(� I' pp-1 II ,^, I'ypc Description JQ,(,(r WS kkA Q19 C)W 13 Unrestricted(Buildings u to 35,000 cu.ft. CilvITown,$ %IF R Restricted 1&2 FamilyDwelling M Masonry RC Roofing Covering WS Window and Siding � �F SF Solid Fuel Burning Appliances S12> L6 Von yQnip,)'�VjVLV�ip�u 1 Insulation Tele hone Email address Wl D Demolition 5.\2 `Registered Home Improvement Contractor(HIC) �LULLV� SO�ar GeV?IOPEY LLC. L 10$ k8 1 HIC Com an Name or HIC R �— HIC Registration Number E.piral on ate 4�3 p� DO . _ gg�stranl Name N5'o"�.a�nd Street W 1'V�aso lla rQ V l V lyl-t-So I0_r. F�1" Vo SI}tOD4 �1$13D53O1p5 Email address �yvt Cit /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application, Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes..........A No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize VI V I I� Sfl l cu-' to act on my behalr,in all mailers relative to work authorized by this building permit application. 24�UL.e 9/6/14 Print Owner's Name(Electronic Sig`natum) Date SECTION 76:OW NE W OR AUTHORIZED AGENT DECLARATION [Byentering my name below, I hereby attest under the pains and penalties of perjury that all ofthe information ed in Ih' p lion is true and accurate to the best of my knowledge and understanding. V car^ ot-to`b9 wr -s r rizedAgetu's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.nrass gov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage, fmished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths 'Type of heating system Number of decks/porches 'type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" A4CC>RV CERTIFICATE OF LIABILITY INSURANCE °;ro;/2o 3°"""" THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(iss)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX DENVER,CO 80202-5534 E-MAIL IN Not, Attn:DenvefoadrequestQ@mmIn.mm,Fax 212.948.4381 ADDRESS: INSURE S AFFORDING COVERAGE NAICIf 462738-STND-GAWUE-13-14 'SURER A:Evanston Insurance Company 35378 INSURED National Union Fire InsUranC Co Of PA Vivint Solar,Inc. INSURER B: 4931 N 300 W UISURER c:Nam'Hampshi2 Insurance Company 23841 Provo,UT BM04 INSURER D INSURER E: IN$URERF: COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR SIR TYPE OF INSURANCE AODL UBR POLICY NUMBER MOD EFF YM M1013 LIMITS A GENERALLu°RUTY 13PKGWE00274 1110112013 1110112014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY MA R 50,000 CLAIMS-MADE M OCCUR PREMISE Ea o Pmsce $ 6,000 MED FJ(P(Arty onee person) E PERSONAL&ADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEML AGGREGATE UNIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 2,000,000 X POUCYFI TA LOC $ B AUTOMOBILE LUI UW 9701087 11/012013 1110112014 COMBINEDSINGLE LIMIT 1,000,000 Ee aoduu B X ANY AUTO 9701088 11/012013 11101QO14 BODILY INJURY(Per person) $ AAUTO ONMED SCHAUTOS BODILY INJURY(Peracddem) $ X X NON-OWNED -PROPERTY-DAMAGE HIREDAUTOS AUTOS Peracddem $ A UMBRELLA LAB OCCUR 13EFXWE00088 11/012013 11101/2014 EACH OCCURRENCE $ 10,000,000 X EXCESS LIAR XCLAIMS-MADE AGGREGATE $ 10,000,000 DEO I I RETENTION$ 1 1$ C WORKERS COMPENSATION 029342334; 029342M 111012013 11/0112014 X I WCSTATU- I OTH- AND EMPLOYERS'L000TY C ANY PROPRIETOR/PARTNERIEXECUMVE YIN 029342336. 029342337 11/0112013 11/0112014 1,000,000' E.L EACH ACCIDENT $ C DFFICE"N In BERNH)EXCLUDED? N NIA 029342338 11/012013 11N1/2014 EL DISEASE-EA EMPLOYE $ 1,000,000 I(Mandatory NH) ddescribe under OES 1,000,000 DCRIPTION OF OPERATIONS bebw E.L.DISEASE-POLICY LIMIT $ A Errors&Omissions& 13PKGW00029 11/012013 11101/2014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (Atbch ACORD 10/,Additional Remar Schedule,N n space is requh,d) e Certificate Holder and others as defined in the written agreement ale included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- nMbutory war any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract Waiver of subrogation is applicable where required by written ntract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRAT10N DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of f1ersh USA Inc. Kathleen M.Parsloe .{�iS,IlvAc.7Jr.1'il[¢CK. ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010105) The ACORD name and logo are registered marks of ACORD The Conaanonwealth of Alassachtisetts Department of Industrial Accidents Office of Investigations r yd 1 Congress Street, Suite 100 'd Boston,M4 02I14-2017 wilviminass.sovIdia Workers' Compensation Insurance Affidavit- Builtders/Corntractors(Electrecianas/Plumbers Anyticannt Information Please Priant I e�ibdv Name (Business/Organization individual): Vivint Solar Developer, LLC Address: 4931 North 300 West '48G4 _ Phone#: 801-704-9389 Are you an employer? Check the appropriate box: 'type of project(required): j 1.® 1 am a employer with 10 4 ❑ I am a general contractor and I I i employees (full and/or part-time).* ' x the retractors 6. ❑ New construction 1 2.❑ i am a sole proprietor or partner- -,ice. ,� t " ru, �,i =.heet. I 7. ❑ Remodeling ship and have no employees i h: n �<<r�t I n have l. 8. ❑ Demolition j working for me in any capacity. amp n nt I r ,,orkers' 9. ❑ Building addition f [No workers' comp. insurance comp. insurance. i required.] 5. ❑ We are a corporation and its T ME Electrical repairs or additions ' 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions j myself. I o workers comp. right of exemption per MGL ' Y P j i 12.17 Roof repairs insurance required.] t c. f 52, §I(4),and we have no — employees. [No workers' f i 13.❑ Other— — — comp. insurance required.] 'Any applicant that checks box f 1 must also tilt out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp_policy number I am an employer that is providing workers'cooupensation Insurancefor my employees. Below is the policy and job site information. Insurance Company Name:—_ New Hampshire Insurance Company_ Policy#or Self-ins. Lic 9: 029342228 Expiration Date: 11/01/14 Job Site Address:_` � ,� �� _ City/State/Zip:_ _ �� ) Attach at copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under :f. irrr ,r:t r ri._• /r:t t She information provided above is true and correct Official use only. Do not write in this area,to be completed by city or town official. ^Il f ffl' City or Town: _ _ Permit/License 9 I Issuing Authority(circle one): '1 fl.Board of Health 2. )Building Department 3.City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other { Contact Person:_ Phone —_-- j a v y u 1 a A"L" - V UILI J S I V Boston, Massachusetts 02116 Home ImprovementContractor registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAiMES SHERMIAM 4931 (NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. 0 Address ❑ Renewal ❑ ?Employment LostCarc dM Massachusetts -Depa'tment of Public Safety Board of Bui!c'ir,,- Reg •!at;oos and Standards Construction Supenisor License:CS 2a',l ` a> ---- - 9. d_kMzS R SHEW4-s dK Alth 6 Fo-Hollow FDrbie StYQaLSxA 01YO6 '� y Expiration Cornmassioner QD l2E$lZO B 4931 North 300 West Structural Group Provo,UT84604 P: (801)234-7050 Scott E. Wyssling, PE Head o/Structural Engineering Scott.wysslingOa vivintsolar.com August 27, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Malewicki Residence 11 Larkin Lane, Salem MA AR#3226414 4.25 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 16"on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCEISEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 26 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. bibint. ` Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF=Live Load(around snow load) • 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 Yz', is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve tru ly yourss, /^) tN OF `Y. _V � E Cyr V QIVI N Scott E.Wyssl PE ° 50 MA License N .50 9�F F�isT FSSlONAI. c JUNCTION BOX ATTACHED TO 5'OF 1"PVC CONDUIT g ARRAY USING ECO HARDWARE TO FROM JUNCTION BOX TO ELEC PANEL KEEP JUNCTION BOX OFF ROOF �J rn ow om Adz z L) w o PV SYSTEM SIZE: � 4.25 kW DC I I u 5 I I 1 I I I Q 4ina Solar TSM-250 8 MODULES WIT En A Enohase M215�60.2LL-52x-ZC 2z-ZC MICRO-INVERTER MOUNTED ON THE BACK OF EACH MODULE AMM b I e a c $ Sm � ^ o � I I N K U 6 V INTERCONNECTION Z M POINT,LOCKABLE > E w DISCONNECT SWITCH, > z Lj ANSI METER LOCATION, a K N I 1 8 UTILITY METER LOCATION J U z z N Q K 2 SHEET NAME: I I Wg � a 11 Larkin Ln , Salem MA 01970 SHEET NUMBER: r PV SYSTEM SITE PLAN 4 SCALE: 3/32"= T-0" d r 3 88o II ^�o ism s� 00 N� 0 N_ Z N m D � r m � -< w C/) \L 30 m 055 O O z m 0 my �o w# Orn T um�m D i Z �= aiINSTALLER:VIVINTSOAR Malewicki Residence P\/ O my ROOF my MALICENSEMBER:7877.404.4121 `/ Sj IVA01 V p /� MA LICENSE:MAHIC 170848 v u. Salem,MA 01970 PLAN DRAWN BY:MSM AR 3228414 ast MotliSetl 8R6/2014 UTILITY ACCOUNT NUMBER 505049B000 CLAMP MOUNTING SEALING m PV3.0 DETAIL WASHER o LOWER Cn op SUPPORT �r Yf- PV MODULES, TYP. MOUNT \ Z hp.. NO OF COMP SHINGLE ROOF, FLASHING PARALLEL TO ROOF PLANE / 3„ C 5/16"8 z 4 1/2" MINIMUM PV ARRAY TYP. ELEVATION STEEL LAG SC S SCREW NOT TO SCALE TORQUE= 1312(t-Ibs CLAMP ATTACHMENT NOT TO SCALE m e •e m CLAMP+ ATTACHMENT CANTELEVER L/4 OR LESS �G COUPLING L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE N a MODULE CLAMP SPACING. 4e COUPLING rc " cO `� PERMITTED 3 m o CLAMP+ CLAMP CLAMP m rc ATTACHMENT NG z m COUPLING SPACI PHOTOVOLTAIC MODULE = y > z w ww m i � � z m w z < 3 SHEET NAME: L=PORTRAIT �-: U) CLAMP SPACING Z Q 0 F- O ECO 2 O L=LANDSCAPE MODULEIBLE PV SYSTEM MOUNTING DETAIL SHEET T rvuMeER: CLAMP SPACING (MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE M NOT TO SCALE a Inverter Ratings(Guide Section 4) invader MaFe/MWel Enpeaer Mv1S6o21T-S2x- Conduit and Conductor Schedule MODULE DETAIL Max oe von Rating 45 Vera Tag Deropern Are amcomuumrs cnodic Type Corpus.- Q) Max Power @40°C pts V]aM 1 Enphaseengage WMe-THAN-2 12 PWG 4 CON N/A-Free Nr Nominal AC Voltage 240 Vs. 6PWG NIP-Free Pn N/P-Fre9ltir C se Tdna Solar TSM-250 Pi 18 Max AC Current os Amps 1 Fare Copper Ground EcrAGEcI 1 SOLAR MODULE Max OCPO Rating p Ampe 2 TRAni G'a 6 PVC 0'-1' TWA Max NvmOer M ParuIGGirtuit 1] 0 iHWwg-Gmurd 9AWG 1 WC 0'-1- V/ N ] THWw2 9AWG 3 PVC 0'1' NOTES FOR INVERTER CIRCUITS(Gold.Segipn 8 antl 9), J m w O AWc 1 PAC n'-1' a 1Hwwz_Gsgvnd _ NN m 1.)IF UTILITY REQUIRES A VISIBLE BREAK SWITCH,DOE,THIS PV Module Ratings @ STC(Guide Section 5) L.1_ <� Enchants M21 S60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? M z MICR04NVERTLR AT YES NO X NA Model MakelMadel Tone Soler TSM-250 PAi E 2 EACH MODULE,ATTACHED Max Pow'er-Pomt Current(imp) 8.27 Amps WITH ECO HARDWARE 2)IF GENERATION METER REQUI RED,DOES THIS METER Max Power-Point Voltage Word) 303 to V^yq0 SOCKET MEET THE REQUIREMENTS? Open-Oimuit Volans Vot) 37.6 Volts ` U YES NO XNA ,hot i¢uil current(list) 8.85 Amps 5 Q 3.)SIZE PHOTOVOLTAIC POWER SOURCE(Di CONDUCTORS Max Series Fuse(OOPD) 15 Amps BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STO noose.) 250 Wahl MICROINVERTER CONNECTION RATING AT DISCONNECT. Maximum System Voltage 1000(IEC)76 1UL) o TO ENGAGE TRUNK CABLE 4J SIZE INVERTER OUTPUT(AD)CONDUCTORS ACCORDING V.Temperature Coefceenl -D32 %PC G V TO INVERTER 01 AMPERE RATING(See Guide Section 9). S)TOTALOF 1 INVERTEROCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WRONG(Guide Section 6 and 8 and Appendix Dl: PV CIRCUIT,DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN IT Lowest expected ambient temperature based an ASHRAE minimum mean extreme NEC690.64(8)(2)(a)7 AYES NO dry bulb temperature for ASHRAEIocai most similar to installation location: -19-C 46 BARE CU GROUND _(GROUNDING ARRAY) signs(See Guide Section 7) 2,)Highest continuous ambient temperature based on ASHRAE highest month 2%Cry bulb temperature for ASHRAE Iocatian most similar to Installation Increase: 39-C Sign for inverter OCPO and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%tlesign temperatures do not exceed 47-C in the United States(Palm Springs,CA is 44.1°CL For less than 9 current-carrying eonductors Solar P f System AC Point of Connection in roof-mounted sunlit conduit at least CS above roof and using the outdoor design AC Output Cuaent 15.300000 Amps temperature of 47-C or less(all of United States), JJam�• Nominal AC Voltage 2401 Volta a.)12 AWG.90-C conductors are generally acceptable for modules with lsc of 7.68 Amps a or less when protected by a 12-Amp or smaller fuse. co SOIAR THIS PANEL FED BYMDSOI R W SOURCES Is110 AG.90°C conductors are generally acceptable for modules with bm of 9.6 Amps (UTILITY AND ) or less when protectedb a 15-Amp or smaller fuse. •gym NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY •� ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR or m a I'd ENVOVBOX co or w ha de to soc, 0 a R Go z co WP Q E to POINT OF DELIVERY > w AND INTERCONNECTION w w w el \'SQ 1P SIEMENS a < 0 z \G G 60N240V F ms'e -QO\N�ZQ MURRAY UNFUSED NEMA3 M ? 2e p Q \�V-�F COMBINER SREC/ANSI LNF222R OR SHEET PV CIRCUIT 1: 77 MODULES/PARALLEL 0 G� PANEL 125A/240V METER EQUIVALENT NAME 4\\<- LWO04NR \.p OR EQUIVALENT DD EXISTING 2 n • • • O O \ IS 240V1125A W Q A/A1 LOAD-CENTER Z E le \\ 20A f • • • J` Jx \ 20A SHEET ____ __ •____ A__ ___�__ _ ______ ____ ____ _ NUMBER . 'T \\ MILBANK VISIBLE/LOCKABLE 1_ JUNCTION BOX Q \\ 3 100A OR 3 'KNIFE'A/C 3 O WITH IRREVERSIBLE \ EQUIVALENT DISCONNECT NECK 014 Compliant GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 W Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Dorothy Malewicki Project Address: 11 Larkin Ln,Salem MA A.System Description: The array consists of a 4.25 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(17) 250-watt modules and(17)215-watt micro-inverters,mounted on the back of each PV module.The array includes (1)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecofibrium Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Camp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2. For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecollbrlum Solar b.Product Name: Ecorail c.Total Weight of PV Modules and mounting hardware: 731 Ibs d.Total number of attachment points: 27 e.Weight per attachment point: 27.07 Ibs f.Maximum spacing between attachment points: ` See attached engineering talcs g.Total surface area of PV array: 299.37 square feet h.Array pounds per square foot: 2.44 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (17)modules,(27)attachments 27.07 pounds vivint. solar 3. Electrical Components: A.Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 17 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voc-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Isc-rate short circuit current - 8.85 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 17 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.Stan voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 105 amps 2.Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 1 PV circuit 1 - 17 modules/inverters (20)amp breaker 2011 NEC Article 705.60(B) Hidint. clod D.Electrical Calculations 1.PV Circuit current PV circuit nominal current 15.3 amps Continuous current adjustment factor 125% 2011 NEC Anidc 705.60(B) PV circuit continuous current rating 19.125 amps 2.Overcurrent protection device rating PV circuit continuous current rating 19.125 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1" above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b. PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Article 705.60(B) Adjusted PV circuit continuous current 26.9 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 3 conductors Conduit fill derate factor 100% 2011 NEC Arice 705.60(B) Final Adjusted PV circuit continuous current 26.9 amps Total derated ampacity for PV circuit 26.9 amps Conductors(tag2 on Mine)must be rated for a minimum of 26.9 amps THWN-2(90°C) #12AWG conductor is rated for 30 amps (Use#12AWG or larger) 2011 NEC Amde 705.60(B) 4.Voltage drop(keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1.Nhirco-inverter voltage drop: 0.39% The largest number of micro-inverters in a row in the entire array is 9 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.39%. 2.AC conductor voltage drop: =I x R x D (=240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#12AWG copper) x (Total wire run) _ (Circuit 1 nominal current is 15.3 amps)x(0.00201Q)x(90)-(240 volts)x(100) 1.15% Total system voltage drop: 1.54% v1Vint. sol i p EcolibriumSolar Customer Info Name: Email Phone: Project Info Identifier: 9441 Street Address Line 1: Street Address Line 2: City: State: Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-250 PA05.18 Module Quantity: 17 Array Size (DC watts): 4250.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 41.0lbs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load-Lateral: 300 Ibf EcoX De sign es gn Load -Downward: 493 Ibf EcoX Design Load -Upward: 568 Ibf EcoX Design Load- Downslope: 353 Ibf EcoX Design Load-Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-05): 1 Roof Type: Composition Shingle Average Roof Height: 15.0 ft Least Horizontal Dimension: 15.0 ft Roof Slope: 26.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.8 0.8 0.8 Roof Snow Load 26.9 26.9 26.9 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 9.4 9.4 9.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 26.9 26.9 26.9 psf Downslope:Load Combination 3 11.6 11.6 11.6 psf Down: Load Combination 3 23.8 23.8 23.8 psf Down: Load Combination 5 11.5 11.5 11.5 psf Down: Load Combination 6a 25.4 25.4 25.4 psf Up:Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 25.4 25.4 25.4 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 65.1 65.1 53.0 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 48.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.7 21.7 17.7 in Spacing Results(Portrait) ' Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 43.0 43.0 32.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.3 14.3 10.9 in Layout S. t• 4 t k �R'r M$ Y. �' s y f v.. yig I s s , '� kWW51. All s S s, ySs �b 1 4 i ri Skirt e Coupling Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Clamp maximum allowable overhang. Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 697 Ibs Weight of Mounting System: 54 Ibs Total System Weight: 751 Ibs Total Array Area: 299 ft2 Distributed Weight: 2.51 psf Number of Attachments: 27 Weight per Attachment Point: 28 Ibs Bill Of Materials Part Name Quantity ESEG01CLASA EcoX Clamp Assembly 27 ESEG01 COASA EcoX Coupling Assembly 24 ESEG01 SKKTA EcoX Landscape Skirt Kit 6 ESEG01 SKKTA EcoX Portrait Skirt Kit 0 ESEG01 CPKTA EcoX Composition Attachment Kit 27 ESEG01 ELASA EcoX Electrical Assembly 1