9 LARKIN LN - BPA-14-713 The Commonwealth of Massachusetts REC
Board of Building Regulations and Standards INSPECTOR ��Kt5
Massachusetts State Building Code,780 CMR SALEM
Revtt'ss!d {���1 Building Permit Application To Construct,Repair,Renovate Or I iemir
One-or Two-Family Dwelling W►�
This Section For Official Use Only
Building Permit Number: Date Applied-
Building Official(Print Name) Signa a Da
SECTION 1:SITE INFORAATION
1.1 Property Address: 1.2 Assessors Map&Pat eel Numbers
9 Larkin Lane
l.la Is this an accepted street?yes_ no _ Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions;
Zoning District u�. Proposed Use Lot Area(sq ft) Frontage(R)
1.5 Building Setbacks(ft)
Front Yard a Side Yards Rear Yard
Required Provided Required provided I equired Provided ,
1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Swage Disposal System:
Public O Private❑ Zone: _ Outside Flood Zone? Muai ipal O On site disposal system 17
Check ifyes0
SECTION 2: PROPERTY OWNERSHIP'
2.1 Owner'of Record:
Todd Schumacher Salem.MA 0 1970
Name(Print) City,State,ZIP
9 Larkin Lane 978-745-7693
No.and Street Telephone Email Address
SECTION 3:DESCRIPTION OF PROPOSED WORK=(checl all that apply)
New Construction❑ Existing Building 1� Owner-Occupied O Repairs(s) ❑ Zteration(s) ❑ Addition ❑
Demolition ❑ Accessory Bldg.❑ 1 Number of Units' Other 0 pecify: solar
Brief Description of Proposed Work :
Installation of a 2.50 kw 10 anels rooftOD solar array
-. SECTION 4:ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs:
(Labor and Materials Official Use Only
1.Building $ 4,000 1. Building Permit Fee:$ Indicate how fee is determined:
2.Electrical $ 17 Standard CityiTown Applica'on Fee
8,075 ❑Total Project Cost'(Item 6)x multiplier x
3.Plumbing $ 2. Other Fees: $
4.Mechanical (HVAC) $ List: I
5.Mechanical (Fire
;oppression) LE
Total All Fees:$
Check No.I Check Amo t: Cash Amount:❑Paid in Full ❑Outst inding Balance Due:
F"T_1"w 31Z to
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL) 096385 10/8/2014
Romain Strecker License Number Expvation Date
Name of CSL Holder
List CSL Type(see below) U
10 Churchill Place
No.and Street Type Description
U Unrestricted(Buildings to 35,000 cu.ft.)
Lynn,MA 01902 R Restri led l&2 Family Dwelling
City/Town,State,ZIP M Masonry
RC Roof Covetin
WS Wind wand Si
SF Solid Fuel Burning Appliances
781-462-8702 permits@bostonsolar.us I Insul lion
Telephone Email address D I Dem lition
5.2 Registered Home Improvement Contractor(HIC) 1696 8 7/27/2015
The Boston Solar Company HIC Regi tration Number Expiration Date
` HIC Company Name or HIC Registrant Name
10 Churchill Place Militq us
No.and Street Email address
Lynn,MA 01902 781-462-8702
City/Town, State ZIP Telephone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6));
Workers Compensation Insurance affidavit must be completed and submitted with tb is application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes..........Q No...........❑
SECTION 7a:OWNER AUTHORIZATION TO BE COMP ETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
' I,as Owner of the subject property,hereby authorize Romain St
to act on my behalf,in all matters relative to work authorized by this building permil application.
'--7Eile 3/14/2014
' Print Owner's Name(Electronic Signature) Date
SECTION 7b:OWNERt OR AUTHORIZED AGENT DE LARATION
By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information
contained in this application is true and ac orate to the best of my knowledge and or derstanding.
Remain Strecker ] 3/14/2014
Print Owner's or Authorized Agent's ame(Electronic Signature) Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner ho hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not ve access to the arbitration
program or guaranty fund under M.G.L.c. 142A.Other important information 4n the HIC Program can be found at
www.mass.gov/oca Information on the Construction Supervisor License can bel found at nn5A ss.eov/dos
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished I asement(attics,decks or porch)
Gross living area(sq.ft.) Habitable room ount
Number of fireplaces Number of be ms
Number of bathrooms Number of half/ aths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
t 3. "Total Project Square Footage"tray be substituted for"Total Project Cost"
.t
EAHI Structural Consulting
351Cendall Court
C Redenrd, NA nl 730
PHONE 1.978..4 06.8921
EA Wp E lain c PEAHStructural.com
January 18,2014
To: Sungevity
66 Franklin Street
Oakland,CA 94607
Subject: Structural Certification for Installation of Solar Panels
Schumacher Residence
9 Larkin Lane
Salem,MA.01970
To Whom It May Concern,
A design check for the subject residence was done on the existing roofing and framing systems for the installation of
solar panels over the roof. From afield inspection of the property,the existing roof support structures were observed
as follows:
The roof structure of(MP1)consists of composition shingle on roof plywood that is supported by nominal 2x6 rafters @
16"o.c.,paired with nominal 2x6 ceiling joists @ 16"o.c..There are 2x4 collar ties at every rafter which frame out an
enclosed attic.The rafters are supported 4'-6"from the exterior wall by veritcal struts which work with collar ties and
ceiling joists to provide a truss system to support the rafters above.The rafters have a max projected horizontal span of
8'-0",with a slope of 35 degrees.The rafters are connected at the ridge to a continuous 2x8 ridge board and are
supported at the eave by a load bearing wall.
The existing roof framing system of(MP1) is judged to be adequate to withstand the loading imposed by the installation
of the solar panels. No reinforcement is necessary.
The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of
loads.
I further certify that all applicable loads required by the codes and design criteria listed below were applied to the
Ironridge solar rail system and analyzed. Furthermore,the installation crews have been thoroughly trained to install the
solar panels based on the specific roof installation instructions developed by Ironridge for the racking system and
Ironridge for the roof connections. Finally, I accept the certifications indicated by the solar panel manufacturer for the
ability of the panels to withstand high wind and snow loads.
Design Criteria:
• Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and 2005 NDS
• Roof Dead Load=12 psf(MPS)
• Roof Live Load=20 psf
• Wind Speed=100 mph,Exposure C
• Ground Snow Load=40 psf - Roof Snow Load=28 psf
Please contact me with any further questions or concerns regarding this project.
OFAf4,9
Sincerely, �@ o
ELAINEA. u
o HUANG
CIVIL m
Elaine Huang, P.E. No.49029
O C
Project Engineer 6O
9S/ONAL O
Schmacher Structural Calcs 1
2 3 4 5
THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC
/\ POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE
\ MOST RECENT NATIONAL ELECTRIC AND BUILDING CODES
/ - AND STANDARDS,AS AMENDED BY LOCAL JURISDICTION.
\ oa��$"OFMgo_c5
EIAINEA.-``WW
/\ AN
CIVIL
y JURISDICTIONAL IN FORMATION: A
,e 9`No.49029Q x JURISDICTION: SALEM,CITY OF
P
ADDRESS: 120 WASHI NGTON ST.
SAL
S/ONRL ENS SALEM,MA 01970
O
OPHONE NUMBER: (9]8)]45-9595
SYSTEM SUMMARY
\ O THIS GRID TIED 2.5 KW DC,2.16 KW CEC AC ROOF
�\ MOUNTED SOLAR ELECTRIC SYSTEM WITHOUT
(EJ sFD ENERGY STORAGE COMPONENTS CONSISTS OF:
(10)ET SOLAR ET-P66025OBB
(1)SMA AMERICA SB3000TL-US-22(240V)
�\ NOTES TO INSTALLER:
B /� \�\N CONDUIT RUN DC CONDUIT RUN:FROM SOLADECK UNDER ARRAY B
IN BASEMENT ROOF-MOUNTED ALONG RIDGE TOWARDS SOUTH WEST SIDE,
PENETRATE EAVE, DOWN WALL,THEN INTO BASEMENT TO
INVERTER. AC CONDUIT RUN:FROM INVERTER BACK OUTSIDE
TO AC DISCONNECT THEN INTO BASEMENT TO[El MSP.
y MONITORING RUN:LGATE 120. ADDITIONAL NOTES:LAND
INVERTER BREAKER AT OPPOSITE SIDE FROM MAIN BREAKER IN
9 ,/ \� ROOF-MOUNTED (E)MSP. -
P
SITE PLAN N � CONDUIT
< � ..,o . ■
SCALE: 1/32"=1'-0" CONDUIT RUN PENETRATES EAVE
THEN DOWN AND ACROSS WALL INTO
BASEMENT TO INVERTER
INVERTER WITH INTEGRATED DC DISCONNECT SHEET NUMBER SHEET TITLE
ON SOUTH EAST INTERIOR WALL IN BASEMENT pV1 0 COVER AND SITE PLAN
CONDUIT RUN UNDER EAVE AND LOCUS MONITORING UNIT NEXT TO INVERTER
C PV2.0 STRUCTURAL C
DEDICATED PV AC DISCONNECT
NEXT TO UTILITY METER MAIN SERVICE ENTRANCE PV3.0 ELECTRICAL DETAIL
UTILITY METER ON SOUTH WEST IN BASEMENT PV3.1 CALCULATIONS
NOTE:BALANCE OF SYSTEM(BOB)EQUIPMENT EXTERIOR WALL PV4.0 LABELS
SHOWN FOR REFERENCE TO LOCATION ONLY-
NOTTOSCALE COVER AND SITE PLAN
SITE PLAN DETAIL SCH A - 646174
L
NEP. 9 ARKINKIN LANE
---- PROPERTY UND ®BOgpgNEL SCALE: 1/9"=1'-0" N SALEM, MA 01970
---- CONDUIT RUN QDCMSCONNECr
— ORI a AY pr nc DlscoNNEcr (978)74$-7693/#646174
0 AGUNR MODULE
Q MAIN SERVICE 24UNCTION BW
Q METER L]MONITORING UNIT
® PV METER Q COMRINER BOX P V 1.0
Q INVERTER ❑ROOF OBSTRUCTION
2 3 4 5
SYMBOL KEY: MODULE SPECS
0 MOUNT HOT EI SOLAR ET-PSK250136
MODULE WEIGHT: 42.59 Las
---- RAIL MOOULE LENGTH: 60.ST
-- RAFTERS MODULE WDTH. 29.0E
ROOF ROOF SPECS
SOLAR MODULE RAFTER SIZE: 39
RAFTER SPAN'. B'-P
= RAIL SPLICE 3' RAFTER SPACING 1E OC
A ®""O� STRING CONFIG. ROOF MATERIAL COMPOSITE SHINGLES
ARRAY 1 SPECS A
NUMBER OF MODULES. 10
TOTAL MODULE WEIGHT: 4259 LB5
- RACKING WEIGHT: 123 1 LOS
l ARRAY WEIGHT. W90 US
ARRAY AREA. 175.1 SOFT
A PAY DEAD-O
1 NU BER OF MOUNTS: 32LSOFT
- -1 - - f- LOAD PER MOUNT: 2BSLBS
ROOF PITCH: J5-
II NUMER OF FLOORS 1
I
li I I I I I I I I I I I 'I I
li I I I I I I I I I I I I I I I II I
l I I t I ---I t f I -�I I it
B I 1 I 1 I 1 1 it �FpYSN OFM4s� B
.. ._. ._. ._. ._.�._.�._.�._.�._.�._.�._.J._. ._
�S ElNE A. m
HUANG
CIVIL
,e ®Na.4902bo
eG
S/ONAL ENU
RRAYLAYOUT N
1 AZIMUTH 14 'TN SCALE 3/16"-1'0"
REFER TO ARRAYS S FOR ROOF PITCH
STRUCTURAL NOTES'.
t. MOUNTS ARE APPROXIMATE LOCATION BUT
ACCURATELY SPACED
SOLAR MODULE - 2. MOUNTS SHOULD BE STAGGERED WHEN POSSIBLE TO
IRONRIDGE XRS RAIL EVENLY DISTRIBUTE LOAD AMONGST RAFTERS
C IRONRIDGE 6105-T5 ALUMINUM L-FOOT C
3. DO NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN
OUICKMOUNT SHINGLE FLASHING TVJO MOUNTS
AND LOW PROFILE MOUNT
COMPOSITE SHINGLES
3/4"PLANK ROOF DECKING LAYOUT AND STRUCTURAL
(1)a"x5"S.S.LAG BOLT c� u r+
MIN j" RAFTER EMBEDMENT SCHUMACHER - 646174
9 LARKIN LANE
24 RAFTER SALEM, MA 01970
(—O-�MOUNTI NG DETAIL (978) 745-7693/#646174
PV2.0
2 3 4 5
Conduit Schadi l MODULE ELECTRICAL SPECS
TAG Conductors Conduit (10)ET SOLAR ET-PW025OBB
SHORT CIRCUIT CURRENT()¢[)'. BTBA
_ OPEN CIRCUIT VOLTAGE Nq.o ]2.4]V
A TO STRAIN RELIEF OPERATING CURRENT(IMP) e24A
OPERATING VOLTAGE PIMP): 3XSI V
B (2 #10 THWN-2 1/2 in.EMT MAX SERIES FUSE RATING: 15A
(1)#10 THWN-2 STn RATING: 250w
(3)#10 THWN-2 CEC PTC BATING OP.]W
DESIGN CONDITIONS
A C (1)#8 THWN-2 1/2 in.EMT HIGHEST M OR DESIGN TEMP.PCf. R•C A
MIN.MEAN EXTREME ANNUAL OB(-C): _Ia-c
(3)#10 THWN-2
(3)#10 THWN-2 INVERTER 1 SPECS
D (1)#8 THWN-2 1/2 in.EMT PNATEDWATTSMA TEFCH�OGTL-usaz l249q GOSGw
1 #10 THWN-2 AC OPERATING VOLTAGE. 240V
(3)#10 THWN-2 mooVLES PERSTRINCNT 11u
E (1)48 THWN-2 1/2 in.EMT INVERTER EFFICIENCY:
INTEGRATED DC DISCONNECT SMTCH
(1)#10 THWN-2 INVERTER 1 STRINGING(690.53)
NOTE MM POWER POI NT CUR RENT(IMP): B.2A
MAX POVYER POINT VOLTAGE(VMP): 30]q V
SINGLE#10 AND GROUNDING CONDUCTORS FROM INVERTER TO (E)200A MISS[MURRAY) MAX SYSTEM VOLTAGE PIGS)SIX 7A)t 4.2V
EXISTING GROUNDING SYSTEM COMPLIES WITH ARTICLE 690.47 FOR 240V 2P 3-W iF SOURCE CIRCUIT CURRENT psq ego 81 U.GA
DC GEC AND AC EGG.
MAX SHORT CIRCUIT CURRENT HOC)690 SAG 110A
200A MAIN
METER
AC DISCONNECT, (E)LOADS
B A B pV INVERTER WITH C LGATE-120 MONITOR/B-LINE D 30AMP, E B
DC DISCONNECT 011 METER SOCKET NON-FUSIBLE,C-H (E)LOADS
DG221 URB
G 1SGng(s)of OO ` ACw LOCUS 20A 2P
MPPT 1
10 Motlules per string METER
DO OUTPUT — LOAD LINE JU OF q{4S�c
MPPT2 , ?� ELAINEA 5!tn
JBOX 1 "AMCN ELECTRICAL KEY'
INVERTER i CIVIL
Na.49026 A BREAKER
4 ®PO SWITCH
SCREWTERMINAL
MEMO.UL LISTO JUNCTION TIII! S)ONpI ENG m FUSE
BOX NTH6PC TERMINAL RATINGSSPLICE
LOCATED ON ROOF J • EARTH GROUND
GEC IRREVERSIBLY GPLICEO TO(1)SUNGEVITY SOIADECK m CHASSIS GROUND
EXISTING GEC OR BONDED DIRECTLY ———GEC
TO EXISTING GROUNDING ELECTRODE —EGC
C IMPORTANT C
BACKFED SOLAR BREAKER(S)SHALL BE
INSTALLED AT THE OPPOSITE END OF THE
CIRCUIT OR FURTHEST AWAY FROM THE MAIN
EUEC7RlCA,N0TES: BREAKER.
1, ALL EQUIPMENT IS LISTED FOR USE. ELECTRICAL DETAIL
2. INSTALLER TO FOLLOW NEC AND LOCAL JURISDICTION GUIDELINES,
3. THE POINT OF CONNECTION COMPLIES WT1 APPLICABLE CECMEG
4. ALL WEE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TOTEMPERATORE DEBATING AND
LOCATION, SCHUMACHER - 646174
5. DISCONNECT SHALL BE WEED SO NO BWDES ARE ENERGIZED. I/ L,1
6. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. 9 LARK IN LANE
]. ALL MODULES AMID BACKING SHAUL BE GROUNDED MA IRON RIDGE FAIL INTEGRATED GROUNDING(PLEASE SEE DATA SALEM, MA 01970
SHEET)OR WTH TIN PLATED DIRECT BURA�RATED LAY IN WASHERS.AMID THREAD FORGING DOLTS RNEESE. LUGS USING STAINLESS STEEL HARDNNRE,STAR (978)745-76931#646174
8. ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERG WHERE NECESSARY ACROSS RAIL SPLICE
PLATES TO BOND INDIVIDUAL PIECES OF RAIL.ONLY COPPER qq 10. NVE'FER(S)CONTAINAGROUNDFA CONDUCTORS ULTDEFEOTONANDINTERRUPTIONDEVICEUL BE USED.STRANDED OR SOLID M, OPERLYRATEDCONNECTORS. PVJ.0
11. ALLEOIMTONO ACCOUNT FOR WORST CASE CONOMONS,
1 2 3 4 5
DC WIRE SIZE:
120%Rule on Main Amperage SOURCE CIRCUIT[6900A(1)1(Isc): Isc'1.25 Panel
MIN.DO CIRCUIT[6900(A)2)I(Isc): Isc'12S R STRINGG
M
MIN.DC WIRE AMPACITY: ain pawl oO Sun aN:lAp xoo
[Season,690.0(b),210.19(A)1,215.2(A),110.14(Cp: DC wire size Location AC wire size Inverted Mom Brea4er(q: 2.
THE MAXIMUM OF: pllewable Inpm Oreaker(AI: 40
1.(Isc 125)I(CONDITIONS OF USE) x.ma.sengs c,arle'ral I Sall", f
2.(Isc'125'125)
OERATE WIRE FOR TERMINALS DEPEND NO UPON TEMP. Wa crea.le 1111 di: ers in si—ee(m^ame In ri:
q pl•p•eth-24-): o pLOenar-20): DC EGC Size A
AC WIRE SIZE: lvrll ap aeleif-U Mm.ampe age: las]
INVERTER OUTPUT[690 8(A)i Ilac): INV.OUTPIR'1.25
MIN.AG WIRE AMPACITY I^al'rl: Inp rc, We EGC size: p14
[690 Ste).690 Sun 21019(A)1,2152bu,110.14(C)i: ce Abwa I.W a.oaraa I carat. as as" eaunrillaenn.e: tm
THE MAXIMUM OF:
1.(MV.OUTPUT'125) rnna.a'sew ro aae2zoeam mpfFl: AC EGC Size
2.(INV.OUTPUT)I CONDITIONS OF USE carianafthrax as fell,wmp('Fl. Tegerrt.m.,—,.a ha.cIs xD.OI
DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP.
erria— ra cre in 169081>b: Is. MIN.EGC tlxe: ii
•m mr0.tAp(IwM..I'. 0l5 M•a,xala iz5-Cealuma C111xvs])IA): 13.75
GROUNDING SIZE: M.elr.A 6aNnN.pm a.mm¢1sn lAt wr—ra—(NI
GEC DC Fuse Size
NEC 69047 Wl1r111dlmNs IA): p•tleyaal S.11Min.amperage: 136]
soal per Table 25066 for AC p-ilymaaima(A): rmmalwmwm.N IAWG):
Sized per Table 250.No for OC pMe Mla fuse size MneeaM: 15e fuze
DO EGC ara lAean: .....rywn-mmla.,n m.l<)'. so
Table 250.122 weav aea-1 1-1 mmp....N(N' .tAWa):
Use 156-Isc'i sNn9a(f applca le)
AC EGC mwln3ltt:pwe): OrNEC 250IV
B Sizetl broad on OCPD. B
MAXIMUM SYSTEM VOLTAGE: Max.system Voltages INVI MPPTI
NEC20OW011 requires to use manufacturers Mmmn e.rn6.e:
fir
COeffident R available
Mir Darr:
Method A:Voc'N of modules in series'NEC Nmm .N ein.' nMor I re
CoeFdent a.at.uara,W a➢mp IW O.
Method B:([(T min°C-25°C)'VPC]i Voc)'p of
motlules in series nmwnmm mrM .al'q:
120%RULE: M•asmerwa.g.:
NEC200R:[$90.Se(B)2]
NEC2011.705.12(D)2
MINIMUM BUS BAR OR CONDUCTOR=
TOTAL NUMBER OF BREAKERS FEEDING 11,2
OCPD SIZING:
MIN DC.ISC'1.55
C MIN AC:INV.OUTPUT'1,25 - C
VOLTAGE DROP:
(2KIDICM)NOLTAGE-100=VOLTAGE DROP%
K-12.9 FOR COPPER
=CURRENT(IMP OR OUTPUT AC) CALCULATIONS
D=DISTANCE FEET,ONE WAY
CM=CIRCULAR MILS
SCHUMACHER - 646174
9 LARKIN LANE
SALEM, MA 01970
(978) 745-7693/#646174
PV3.1
2 3 4 5
NEC 690.5(c) NEC 690.53&NEC 690.14(C)(2)
PLACE THIS LABEL ON INVERTER(S)OR NEAR PLACE THIS LABEL ON ALL PHOTOVOLTAIC DC
GROUND-FAULT INDICATOR(ON INVERTERS)U.O.N.) DISCONNECTING MEANS(ON INVERTER IF INTEGRATED DC NEC 690.31(E)3&4
DISCONNECTS AND AT SEPARATE DC DISCONNECT IF PLACE ON ALL JUNCTION BOXES,EXPOSED
WARNING APPLICABLE) RACEWAYS EVERY 10
INVERTER
q 1 MPPT 1 DISCONNECT PHOTOVOLTAIC POWER A
PHOTOVOLTAIC SYSTEM DISCONNECT
ELECTRIC SHOCK HAZARD RATeo Max POwsR voINTCURRENTIIMVI. axA SOURCE
RATEDMXXPOW RP OIMVOLTAGE(VMP)'. �039V
IF AGROUND FAULT IS INDICATED, MAX SYSTEM VOLTAGE ryoc): 4xs x v
NORMALLY GROUNDED CONDUCTORS SNORT CIRCUIT CURRENT NSO): I TQ A
MAY BE UNGROUNDED AND ENERGIZED
NEC 690.17 NEC 690.54 NEC 705.12(D)4
PLACE THIS LABEL ON ALL DISCONNECTING PLACE THIS LABEL AT"INTERACTIVE POINT OF PLACE LABEL ON ALL EQUIPMENT CONTAINING
MEANS WHERE ENERGIZED IN AN OPEN POSITION INTERCONNECTION-(AT MAIN SERVICE PANEL AND OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER
B WARNING SUBPANEL IF APPLICABLE) TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE
SOURCES. B
INTERACTIVEUT URRENT OLTaIG PoW£R SOURCE
RATEHAC OPERATING
,SA
NOMINAL OPERATING AC VOLTAGE M 240V
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND LOAD CONTAINS MULTIPLE POWER
SIDE MAY BE ENERGIZED IN THE OPEN
POSITION SOURCES
NEC 690.35(F)
PLACE THIS LABEL AT EACH JUNCTION BOX,COMBINER BOX,
NEC 705.12(D)7 DISCONNECT AND DEVICE WHERE ENERGIZED,UNGROUNDED
PLACE THIS LABEL AT P.O.C.TO SERVICE CIRCUITS MAY BE EXPOSED DURING SERVICE:
C DISTRIBUTION EQUIPMENT(I.E.MAIN PANEL(AND C
--SUBPANEL IF APPLICABLE))WARNING WARNING
CONNECTION ELECTRIC SHOCK HAZARD
DO NOT RELOCATE THIS THE DC CONDUCTORS OF THIS LABELS
OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
SCHUMACHER- 646174
9 LARKIN LANE
SALEM, MA 01970
(978) 745-7693/#646174
ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE
LOCAL AHJ.THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS
DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN PV4.0
NEC ARTICLES 6W.5(C),690.14(C)(2),690.17,690.53,690.35(F), 690.54,690.64(B)(7)and 705.10
I,`