Loading...
9 LARKIN LN - BPA-14-713 The Commonwealth of Massachusetts REC Board of Building Regulations and Standards INSPECTOR ��Kt5 Massachusetts State Building Code,780 CMR SALEM Revtt'ss!d {���1 Building Permit Application To Construct,Repair,Renovate Or I iemir One-or Two-Family Dwelling W►� This Section For Official Use Only Building Permit Number: Date Applied- Building Official(Print Name) Signa a Da SECTION 1:SITE INFORAATION 1.1 Property Address: 1.2 Assessors Map&Pat eel Numbers 9 Larkin Lane l.la Is this an accepted street?yes_ no _ Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions; Zoning District u�. Proposed Use Lot Area(sq ft) Frontage(R) 1.5 Building Setbacks(ft) Front Yard a Side Yards Rear Yard Required Provided Required provided I equired Provided , 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Swage Disposal System: Public O Private❑ Zone: _ Outside Flood Zone? Muai ipal O On site disposal system 17 Check ifyes0 SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Todd Schumacher Salem.MA 0 1970 Name(Print) City,State,ZIP 9 Larkin Lane 978-745-7693 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK=(checl all that apply) New Construction❑ Existing Building 1� Owner-Occupied O Repairs(s) ❑ Zteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ 1 Number of Units' Other 0 pecify: solar Brief Description of Proposed Work : Installation of a 2.50 kw 10 anels rooftOD solar array -. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials Official Use Only 1.Building $ 4,000 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ 17 Standard CityiTown Applica'on Fee 8,075 ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: I 5.Mechanical (Fire ;oppression) LE Total All Fees:$ Check No.I Check Amo t: Cash Amount:❑Paid in Full ❑Outst inding Balance Due: F"T_1"w 31Z to SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 096385 10/8/2014 Romain Strecker License Number Expvation Date Name of CSL Holder List CSL Type(see below) U 10 Churchill Place No.and Street Type Description U Unrestricted(Buildings to 35,000 cu.ft.) Lynn,MA 01902 R Restri led l&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roof Covetin WS Wind wand Si SF Solid Fuel Burning Appliances 781-462-8702 permits@bostonsolar.us I Insul lion Telephone Email address D I Dem lition 5.2 Registered Home Improvement Contractor(HIC) 1696 8 7/27/2015 The Boston Solar Company HIC Regi tration Number Expiration Date ` HIC Company Name or HIC Registrant Name 10 Churchill Place Militq us No.and Street Email address Lynn,MA 01902 781-462-8702 City/Town, State ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)); Workers Compensation Insurance affidavit must be completed and submitted with tb is application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes..........Q No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMP ETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ' I,as Owner of the subject property,hereby authorize Romain St to act on my behalf,in all matters relative to work authorized by this building permil application. '--7Eile 3/14/2014 ' Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNERt OR AUTHORIZED AGENT DE LARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and ac orate to the best of my knowledge and or derstanding. Remain Strecker ] 3/14/2014 Print Owner's or Authorized Agent's ame(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner ho hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not ve access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information 4n the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can bel found at nn5A ss.eov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished I asement(attics,decks or porch) Gross living area(sq.ft.) Habitable room ount Number of fireplaces Number of be ms Number of bathrooms Number of half/ aths Type of heating system Number of decks/porches Type of cooling system Enclosed Open t 3. "Total Project Square Footage"tray be substituted for"Total Project Cost" .t EAHI Structural Consulting 351Cendall Court C Redenrd, NA nl 730 PHONE 1.978..4 06.8921 EA Wp E lain c PEAHStructural.com January 18,2014 To: Sungevity 66 Franklin Street Oakland,CA 94607 Subject: Structural Certification for Installation of Solar Panels Schumacher Residence 9 Larkin Lane Salem,MA.01970 To Whom It May Concern, A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From afield inspection of the property,the existing roof support structures were observed as follows: The roof structure of(MP1)consists of composition shingle on roof plywood that is supported by nominal 2x6 rafters @ 16"o.c.,paired with nominal 2x6 ceiling joists @ 16"o.c..There are 2x4 collar ties at every rafter which frame out an enclosed attic.The rafters are supported 4'-6"from the exterior wall by veritcal struts which work with collar ties and ceiling joists to provide a truss system to support the rafters above.The rafters have a max projected horizontal span of 8'-0",with a slope of 35 degrees.The rafters are connected at the ridge to a continuous 2x8 ridge board and are supported at the eave by a load bearing wall. The existing roof framing system of(MP1) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of loads. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the Ironridge solar rail system and analyzed. Furthermore,the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by Ironridge for the racking system and Ironridge for the roof connections. Finally, I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and 2005 NDS • Roof Dead Load=12 psf(MPS) • Roof Live Load=20 psf • Wind Speed=100 mph,Exposure C • Ground Snow Load=40 psf - Roof Snow Load=28 psf Please contact me with any further questions or concerns regarding this project. OFAf4,9 Sincerely, �@ o ELAINEA. u o HUANG CIVIL m Elaine Huang, P.E. No.49029 O C Project Engineer 6O 9S/ONAL O Schmacher Structural Calcs 1 2 3 4 5 THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC /\ POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE \ MOST RECENT NATIONAL ELECTRIC AND BUILDING CODES / - AND STANDARDS,AS AMENDED BY LOCAL JURISDICTION. \ oa��$"OFMgo_c5 EIAINEA.-``WW /\ AN CIVIL y JURISDICTIONAL IN FORMATION: A ,e 9`No.49029Q x JURISDICTION: SALEM,CITY OF P ADDRESS: 120 WASHI NGTON ST. SAL S/ONRL ENS SALEM,MA 01970 O OPHONE NUMBER: (9]8)]45-9595 SYSTEM SUMMARY \ O THIS GRID TIED 2.5 KW DC,2.16 KW CEC AC ROOF �\ MOUNTED SOLAR ELECTRIC SYSTEM WITHOUT (EJ sFD ENERGY STORAGE COMPONENTS CONSISTS OF: (10)ET SOLAR ET-P66025OBB (1)SMA AMERICA SB3000TL-US-22(240V) �\ NOTES TO INSTALLER: B /� \�\N CONDUIT RUN DC CONDUIT RUN:FROM SOLADECK UNDER ARRAY B IN BASEMENT ROOF-MOUNTED ALONG RIDGE TOWARDS SOUTH WEST SIDE, PENETRATE EAVE, DOWN WALL,THEN INTO BASEMENT TO INVERTER. AC CONDUIT RUN:FROM INVERTER BACK OUTSIDE TO AC DISCONNECT THEN INTO BASEMENT TO[El MSP. y MONITORING RUN:LGATE 120. ADDITIONAL NOTES:LAND INVERTER BREAKER AT OPPOSITE SIDE FROM MAIN BREAKER IN 9 ,/ \� ROOF-MOUNTED (E)MSP. - P SITE PLAN N � CONDUIT < � ..,o . ■ SCALE: 1/32"=1'-0" CONDUIT RUN PENETRATES EAVE THEN DOWN AND ACROSS WALL INTO BASEMENT TO INVERTER INVERTER WITH INTEGRATED DC DISCONNECT SHEET NUMBER SHEET TITLE ON SOUTH EAST INTERIOR WALL IN BASEMENT pV1 0 COVER AND SITE PLAN CONDUIT RUN UNDER EAVE AND LOCUS MONITORING UNIT NEXT TO INVERTER C PV2.0 STRUCTURAL C DEDICATED PV AC DISCONNECT NEXT TO UTILITY METER MAIN SERVICE ENTRANCE PV3.0 ELECTRICAL DETAIL UTILITY METER ON SOUTH WEST IN BASEMENT PV3.1 CALCULATIONS NOTE:BALANCE OF SYSTEM(BOB)EQUIPMENT EXTERIOR WALL PV4.0 LABELS SHOWN FOR REFERENCE TO LOCATION ONLY- NOTTOSCALE COVER AND SITE PLAN SITE PLAN DETAIL SCH A - 646174 L NEP. 9 ARKINKIN LANE ---- PROPERTY UND ®BOgpgNEL SCALE: 1/9"=1'-0" N SALEM, MA 01970 ---- CONDUIT RUN QDCMSCONNECr — ORI a AY pr nc DlscoNNEcr (978)74$-7693/#646174 0 AGUNR MODULE Q MAIN SERVICE 24UNCTION BW Q METER L]MONITORING UNIT ® PV METER Q COMRINER BOX P V 1.0 Q INVERTER ❑ROOF OBSTRUCTION 2 3 4 5 SYMBOL KEY: MODULE SPECS 0 MOUNT HOT EI SOLAR ET-PSK250136 MODULE WEIGHT: 42.59 Las ---- RAIL MOOULE LENGTH: 60.ST -- RAFTERS MODULE WDTH. 29.0E ROOF ROOF SPECS SOLAR MODULE RAFTER SIZE: 39 RAFTER SPAN'. B'-P = RAIL SPLICE 3' RAFTER SPACING 1E OC A ®""O� STRING CONFIG. ROOF MATERIAL COMPOSITE SHINGLES ARRAY 1 SPECS A NUMBER OF MODULES. 10 TOTAL MODULE WEIGHT: 4259 LB5 - RACKING WEIGHT: 123 1 LOS l ARRAY WEIGHT. W90 US ARRAY AREA. 175.1 SOFT A PAY DEAD-O 1 NU BER OF MOUNTS: 32LSOFT - -1 - - f- LOAD PER MOUNT: 2BSLBS ROOF PITCH: J5- II NUMER OF FLOORS 1 I li I I I I I I I I I I I 'I I li I I I I I I I I I I I I I I I II I l I I t I ---I t f I -�I I it B I 1 I 1 I 1 1 it �FpYSN OFM4s� B .. ._. ._. ._. ._.�._.�._.�._.�._.�._.�._.J._. ._ �S ElNE A. m HUANG CIVIL ,e ®Na.4902bo eG S/ONAL ENU RRAYLAYOUT N 1 AZIMUTH 14 'TN SCALE 3/16"-1'0" REFER TO ARRAYS S FOR ROOF PITCH STRUCTURAL NOTES'. t. MOUNTS ARE APPROXIMATE LOCATION BUT ACCURATELY SPACED SOLAR MODULE - 2. MOUNTS SHOULD BE STAGGERED WHEN POSSIBLE TO IRONRIDGE XRS RAIL EVENLY DISTRIBUTE LOAD AMONGST RAFTERS C IRONRIDGE 6105-T5 ALUMINUM L-FOOT C 3. DO NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN OUICKMOUNT SHINGLE FLASHING TVJO MOUNTS AND LOW PROFILE MOUNT COMPOSITE SHINGLES 3/4"PLANK ROOF DECKING LAYOUT AND STRUCTURAL (1)a"x5"S.S.LAG BOLT c� u r+ MIN j" RAFTER EMBEDMENT SCHUMACHER - 646174 9 LARKIN LANE 24 RAFTER SALEM, MA 01970 (—O-�MOUNTI NG DETAIL (978) 745-7693/#646174 PV2.0 2 3 4 5 Conduit Schadi l MODULE ELECTRICAL SPECS TAG Conductors Conduit (10)ET SOLAR ET-PW025OBB SHORT CIRCUIT CURRENT()¢[)'. BTBA _ OPEN CIRCUIT VOLTAGE Nq.o ]2.4]V A TO STRAIN RELIEF OPERATING CURRENT(IMP) e24A OPERATING VOLTAGE PIMP): 3XSI V B (2 #10 THWN-2 1/2 in.EMT MAX SERIES FUSE RATING: 15A (1)#10 THWN-2 STn RATING: 250w (3)#10 THWN-2 CEC PTC BATING OP.]W DESIGN CONDITIONS A C (1)#8 THWN-2 1/2 in.EMT HIGHEST M OR DESIGN TEMP.PCf. R•C A MIN.MEAN EXTREME ANNUAL OB(-C): _Ia-c (3)#10 THWN-2 (3)#10 THWN-2 INVERTER 1 SPECS D (1)#8 THWN-2 1/2 in.EMT PNATEDWATTSMA TEFCH�OGTL-usaz l249q GOSGw 1 #10 THWN-2 AC OPERATING VOLTAGE. 240V (3)#10 THWN-2 mooVLES PERSTRINCNT 11u E (1)48 THWN-2 1/2 in.EMT INVERTER EFFICIENCY: INTEGRATED DC DISCONNECT SMTCH (1)#10 THWN-2 INVERTER 1 STRINGING(690.53) NOTE MM POWER POI NT CUR RENT(IMP): B.2A MAX POVYER POINT VOLTAGE(VMP): 30]q V SINGLE#10 AND GROUNDING CONDUCTORS FROM INVERTER TO (E)200A MISS[MURRAY) MAX SYSTEM VOLTAGE PIGS)SIX 7A)t 4.2V EXISTING GROUNDING SYSTEM COMPLIES WITH ARTICLE 690.47 FOR 240V 2P 3-W iF SOURCE CIRCUIT CURRENT psq ego 81 U.GA DC GEC AND AC EGG. MAX SHORT CIRCUIT CURRENT HOC)690 SAG 110A 200A MAIN METER AC DISCONNECT, (E)LOADS B A B pV INVERTER WITH C LGATE-120 MONITOR/B-LINE D 30AMP, E B DC DISCONNECT 011 METER SOCKET NON-FUSIBLE,C-H (E)LOADS DG221 URB G 1SGng(s)of OO ` ACw LOCUS 20A 2P MPPT 1 10 Motlules per string METER DO OUTPUT — LOAD LINE JU OF q{4S�c MPPT2 , ?� ELAINEA 5!tn JBOX 1 "AMCN ELECTRICAL KEY' INVERTER i CIVIL Na.49026 A BREAKER 4 ®PO SWITCH SCREWTERMINAL MEMO.UL LISTO JUNCTION TIII! S)ONpI ENG m FUSE BOX NTH6PC TERMINAL RATINGSSPLICE LOCATED ON ROOF J • EARTH GROUND GEC IRREVERSIBLY GPLICEO TO(1)SUNGEVITY SOIADECK m CHASSIS GROUND EXISTING GEC OR BONDED DIRECTLY ———GEC TO EXISTING GROUNDING ELECTRODE —EGC C IMPORTANT C BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN EUEC7RlCA,N0TES: BREAKER. 1, ALL EQUIPMENT IS LISTED FOR USE. ELECTRICAL DETAIL 2. INSTALLER TO FOLLOW NEC AND LOCAL JURISDICTION GUIDELINES, 3. THE POINT OF CONNECTION COMPLIES WT1 APPLICABLE CECMEG 4. ALL WEE,VOLTAGES,AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TOTEMPERATORE DEBATING AND LOCATION, SCHUMACHER - 646174 5. DISCONNECT SHALL BE WEED SO NO BWDES ARE ENERGIZED. I/ L,1 6. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. 9 LARK IN LANE ]. ALL MODULES AMID BACKING SHAUL BE GROUNDED MA IRON RIDGE FAIL INTEGRATED GROUNDING(PLEASE SEE DATA SALEM, MA 01970 SHEET)OR WTH TIN PLATED DIRECT BURA�RATED LAY IN WASHERS.AMID THREAD FORGING DOLTS RNEESE. LUGS USING STAINLESS STEEL HARDNNRE,STAR (978)745-76931#646174 8. ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERG WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL.ONLY COPPER qq 10. NVE'FER(S)CONTAINAGROUNDFA CONDUCTORS ULTDEFEOTONANDINTERRUPTIONDEVICEUL BE USED.STRANDED OR SOLID M, OPERLYRATEDCONNECTORS. PVJ.0 11. ALLEOIMTONO ACCOUNT FOR WORST CASE CONOMONS, 1 2 3 4 5 DC WIRE SIZE: 120%Rule on Main Amperage SOURCE CIRCUIT[6900A(1)1(Isc): Isc'1.25 Panel MIN.DO CIRCUIT[6900(A)2)I(Isc): Isc'12S R STRINGG M MIN.DC WIRE AMPACITY: ain pawl oO Sun aN:lAp xoo [Season,690.0(b),210.19(A)1,215.2(A),110.14(Cp: DC wire size Location AC wire size Inverted Mom Brea4er(q: 2. THE MAXIMUM OF: pllewable Inpm Oreaker(AI: 40 1.(Isc 125)I(CONDITIONS OF USE) x.ma.sengs c,arle'ral I Sall", f 2.(Isc'125'125) OERATE WIRE FOR TERMINALS DEPEND NO UPON TEMP. Wa crea.le 1111 di: ers in si—ee(m^ame In ri: q pl•p•eth-24-): o pLOenar-20): DC EGC Size A AC WIRE SIZE: lvrll ap aeleif-U Mm.ampe age: las] INVERTER OUTPUT[690 8(A)i Ilac): INV.OUTPIR'1.25 MIN.AG WIRE AMPACITY I^al'rl: Inp rc, We EGC size: p14 [690 Ste).690 Sun 21019(A)1,2152bu,110.14(C)i: ce Abwa I.W a.oaraa I carat. as as" eaunrillaenn.e: tm THE MAXIMUM OF: 1.(MV.OUTPUT'125) rnna.a'sew ro aae2zoeam mpfFl: AC EGC Size 2.(INV.OUTPUT)I CONDITIONS OF USE carianafthrax as fell,wmp('Fl. Tegerrt.m.,—,.a ha.cIs xD.OI DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP. erria— ra cre in 169081>b: Is. MIN.EGC tlxe: ii •m mr0.tAp(IwM..I'. 0l5 M•a,xala iz5-Cealuma C111xvs])IA): 13.75 GROUNDING SIZE: M.elr.A 6aNnN.pm a.mm¢1sn lAt wr—ra—(NI GEC DC Fuse Size NEC 69047 Wl1r111dlmNs IA): p•tleyaal S.11Min.amperage: 136] soal per Table 25066 for AC p-ilymaaima(A): rmmalwmwm.N IAWG): Sized per Table 250.No for OC pMe Mla fuse size MneeaM: 15e fuze DO EGC ara lAean: .....rywn-mmla.,n m.l<)'. so Table 250.122 weav aea-1 1-1 mmp....N(N' .tAWa): Use 156-Isc'i sNn9a(f applca le) AC EGC mwln3ltt:pwe): OrNEC 250IV B Sizetl broad on OCPD. B MAXIMUM SYSTEM VOLTAGE: Max.system Voltages INVI MPPTI NEC20OW011 requires to use manufacturers Mmmn e.rn6.e: fir COeffident R available Mir Darr: Method A:Voc'N of modules in series'NEC Nmm .N ein.' nMor I re CoeFdent a.at.uara,W a➢mp IW O. Method B:([(T min°C-25°C)'VPC]i Voc)'p of motlules in series nmwnmm mrM .al'q: 120%RULE: M•asmerwa.g.: NEC200R:[$90.Se(B)2] NEC2011.705.12(D)2 MINIMUM BUS BAR OR CONDUCTOR= TOTAL NUMBER OF BREAKERS FEEDING 11,2 OCPD SIZING: MIN DC.ISC'1.55 C MIN AC:INV.OUTPUT'1,25 - C VOLTAGE DROP: (2KIDICM)NOLTAGE-100=VOLTAGE DROP% K-12.9 FOR COPPER =CURRENT(IMP OR OUTPUT AC) CALCULATIONS D=DISTANCE FEET,ONE WAY CM=CIRCULAR MILS SCHUMACHER - 646174 9 LARKIN LANE SALEM, MA 01970 (978) 745-7693/#646174 PV3.1 2 3 4 5 NEC 690.5(c) NEC 690.53&NEC 690.14(C)(2) PLACE THIS LABEL ON INVERTER(S)OR NEAR PLACE THIS LABEL ON ALL PHOTOVOLTAIC DC GROUND-FAULT INDICATOR(ON INVERTERS)U.O.N.) DISCONNECTING MEANS(ON INVERTER IF INTEGRATED DC NEC 690.31(E)3&4 DISCONNECTS AND AT SEPARATE DC DISCONNECT IF PLACE ON ALL JUNCTION BOXES,EXPOSED WARNING APPLICABLE) RACEWAYS EVERY 10 INVERTER q 1 MPPT 1 DISCONNECT PHOTOVOLTAIC POWER A PHOTOVOLTAIC SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD RATeo Max POwsR voINTCURRENTIIMVI. axA SOURCE RATEDMXXPOW RP OIMVOLTAGE(VMP)'. �039V IF AGROUND FAULT IS INDICATED, MAX SYSTEM VOLTAGE ryoc): 4xs x v NORMALLY GROUNDED CONDUCTORS SNORT CIRCUIT CURRENT NSO): I TQ A MAY BE UNGROUNDED AND ENERGIZED NEC 690.17 NEC 690.54 NEC 705.12(D)4 PLACE THIS LABEL ON ALL DISCONNECTING PLACE THIS LABEL AT"INTERACTIVE POINT OF PLACE LABEL ON ALL EQUIPMENT CONTAINING MEANS WHERE ENERGIZED IN AN OPEN POSITION INTERCONNECTION-(AT MAIN SERVICE PANEL AND OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER B WARNING SUBPANEL IF APPLICABLE) TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. B INTERACTIVEUT URRENT OLTaIG PoW£R SOURCE RATEHAC OPERATING ,SA NOMINAL OPERATING AC VOLTAGE M 240V ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD CONTAINS MULTIPLE POWER SIDE MAY BE ENERGIZED IN THE OPEN POSITION SOURCES NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX,COMBINER BOX, NEC 705.12(D)7 DISCONNECT AND DEVICE WHERE ENERGIZED,UNGROUNDED PLACE THIS LABEL AT P.O.C.TO SERVICE CIRCUITS MAY BE EXPOSED DURING SERVICE: C DISTRIBUTION EQUIPMENT(I.E.MAIN PANEL(AND C --SUBPANEL IF APPLICABLE))WARNING WARNING CONNECTION ELECTRIC SHOCK HAZARD DO NOT RELOCATE THIS THE DC CONDUCTORS OF THIS LABELS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCHUMACHER- 646174 9 LARKIN LANE SALEM, MA 01970 (978) 745-7693/#646174 ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ.THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO,THAT FOUND IN PV4.0 NEC ARTICLES 6W.5(C),690.14(C)(2),690.17,690.53,690.35(F), 690.54,690.64(B)(7)and 705.10 I,`