34 JAPONICA ST - BUILDING INSPECTION
(�Z ► Iv Cr4� g6 The Commonwealth of Massachusetts {SEC-- V c F R�)lCF_S 1 � • Board of Building Regulations and Standards isdSpE T1t�. CITY OF SALEM (� Massachusetts State Building Code, 780 CMR vip*r I Building Permit Application To Construct,Repair, Renovate Or Dent4t &Al One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Ap ied: (l4 Building Official(Print Name) Signature Date (� SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers _ 34 Japonica St 26-0199-0 l.la Is this an accepted street?yes x no Map Number Parcel Number 1� 1.3 Zoning Information: 1.4 Property Dimensions: R2 ' Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Record: Jason Walcott Salem MA 01970 Name(Print) City,State,ZIP 34 Japonica St 508-367-5480 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ 1 Alteration(s) ❑ I Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other ® Specify: PV Solar System Brief Description of Proposed Workz: Roof mounted grid tied PV Solar System 10 modules @ 285 watts/10 Micro inverters 2.85 KWDC SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ 5489.00 1. Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $ 10000.00 El Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 15489.00 0 Paid in Full 0 Outstanding Balance Due: 10/9/2015 Solar building permit.jpeg SECTIONS: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-108214 V Ede Chammnd License Number Expiration Date Nam of CSL Holder List CSL Type(see below) 4018 27 Sanbom5l No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft. Rchburg MA 01420 R Restricted l&2 Family Dwelling Cilyffown,State,ZIP M Masonry RC libuding Covcrinal wVS Window and Siding SF Solid Fuel Burning Appliances ' 978562-2880 erieebarbarM�endiossmtnsalar.cam I Insulation Telephone Entail address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 174479 1/28115 i Endless Mountains Solar Servtms HIC Registration Number Expiration Date j HIC Company Name or HIC Registrars Name 288 Kidder St Ilmlasaowski@andiassminsolarxom No.and Street Email address Wilkes Barra PA 18702 570-8205990 Cil flown State ZLP Tel hake SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of she building permit. Signed Affidavit Attached? Yes..........29 No .......❑ SECTION 7R:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize Endless Mountains Sala,Service to net on my behalf,i0.a1!'nietlers re to work authorized by this building permit application. � Z0� Prim ame(ElccuomcSi&aume) Date SECTION 7b:O\VNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest tinder the pains and penalties of perjury that all of the information contained in this application is true and a,c(ccurite to the best of my knowledge and understanding. Omaer's or Authanseell Agent's Name(Electronic Signature) Oale NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home improvement Contractor(HIC)Program),will no have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.riiass,gttv/ocq Information on the Construction Supervisor License can be found at invw n� 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/atfics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of halfN,nfhs Type of healing system _ Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" https://mail.google.com/_/scs/mail-static%!s/k=gmail.main.en.ZBOxyLCPvgo.O/m=m_i,Vam=PiNeQMD9v_cHMcYwFn6QoW999 vLIJs5MDr xMGgGSvA... 1/1 ,a►`�o�® CERTIFICATE OF LIABILITY INSURANCE DAIE(MWDD/YYYY) 5/13/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s)- PRODUCER CONTACT Sharon Zaccone NAME: Eastern Insurance Group PHONE (570)819-2000 q/C No: (570)819-4000 613 Baltimore Drive EMAIL szaccone@easterninsurance sou Com INSURERS AFFORDING COVERAGE NAIL N Wilkes Barre PA 18702-7980 INSURER A I]DI-Gerling America Ins Cc 41343 INSURED INSURER B: Endless Mountain Solar Services, LLC, DBA: Quality INSURER C: 286 Kidder St INSURER D: INSURER E Wilkes Barre PA 18703 1 INSURER F: COVERAGES CERTIFICATE NUMBER14aster 15-16 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDTYPE OF INSURANCE INSD MDSUBR POLICY NUMBER MWODYIYYYY EFF POLICY LIMITS LTR X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S 1,000,000 DAMAGE TO RENTED 100,000 A CLAIMS-MADE X OCCUR PREMISES Ea occurrence $ E00000087615 5/9/2015 5/9/2016 MED UP(Any one person) $ 5,000 PERSONAL S ADV INJURY $ 1,000,000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY PRO- ❑ LOC PRODUCTS-COMP/OP AGG $ 2,000,000 JECT OTHER: Employee Benefits Liability $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident A R ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED EAGCC000087615 5/9/2015 5/9/2016 BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per acdtlenf Medical Expense $ 5,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE S EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION $ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY STATUTE ERH ANY PROPRIETOR/PARTNER/EXECUTIVE YIN E.L.EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? N I A A (Mandatory in NH) EWGCC000087615 5/9/2015 5/9/2016 E.L.DISEASE-EA EMPLOYEE S 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be anached If more Space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City Of Salem THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 93 Washington St ACCORDANCE WITH THE POLICY PROVISIONS. Salem, MA 01970 AUTHORIZED REPRESENTATIVE Sharon Zaccone/SZ ����K ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD INS025(9c14n1) The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114-2017 U1V www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Endless Mountains Solar Services Address:288 Kidder St City/State/Zip:Wilkes Barre PA 18702 Phone#:570-820-5990 Are you an employer?Check the appropriate box: Type of project(required): L N I am a employer with 10 4. ❑ I am a general contractor and I 6. ❑ New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition workingfor me in an capacity. employees and have workers' Y p tY� 9. ❑Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no Solar employees. [No workers' 13.X Other comp. insurance required.] *My applicant that checks box#t must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number_ I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:HDI-Gerling America Inc Co. Policy#or Self-ins. Lic.#:000087615 Expiration Date:5/9/16 Job Site Address: 34 Japonica St City/State/Zip:Salem MA 01970 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify nder the pains and penal 'es o erjury that the information provided above is true and correct. ///��� 10/7/15 Sienature Z,__1 _ Date Phone#: 5708205990 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority (circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ENDLESS Mt, ,JNTAINS SOLAR SERVES, LLC 184 CEDAR HILL ST,MARLBOROUGH,MA 01752/OFFICE(508)357-2354 FAX(508)532-3562 WORK ORDER HIC#174479 Reg: 688 of Central NE Demo Date&Time: q 'L I y Referred By: Buyers Name: �1gS0*I (JQ�(c � Type of Installation- o Ground/Ballasted Address: �7 7� .�°f la o n i C't 5 -re?t Roof Type- Shmgl Metal/Rubber/Other: City: S4�{w State:I- M D I 1V Roof Pitch- 0° 10° 15-20°25e0 35'40'45'Other: !� Zip: House Type- Ranch/Modular/Cape/Other: NrIo( Phone: 5o`!i'363- S'H So Work: House Stories- Single 6ZThree!Other: Email: ,etSOY I C +4 If Service Panel- Fuse/60A/ I OOA _ Other: Notes: COMPLETE SYSTEM PACKAGE System Description: Cary 0 Lj& d z'rS' fKAA 64f"re 0,l I Cra Terms: Payment Plans Based On Current Interest Rate COST OF SYSTEM: I t C! 5 Please note the payment schedule: St[N b;f tv/+1 t d' 2 40%-To start permitting f -t� 50%-To start the installation 1151 r 3 9 4 10%-After final inspection by your municipality Sub Total............................................... CASH,CHECK or CREDIT CARD(MOVISA/AMEXIDISCOVER) Tax...................................................... S —� C Total..................................................... 5 2So v15 Cif SELF FINANCE Deposit Received .............. ...... $ 250 Balance Due ................................................ S 1150 h � EMSS FINANCE OPTION, I AUTHORIZE PAYMENTS HEREUNDER TO BE MADE TO MY CREDIT CARD exp.date Company Representative: j`t6 f tf. Buyers Signature: IMPORTANT CUSTOMER INFORMATION ' Any claims,discounts and/or promises made or otherwise offered during any sales Date: presentation must be in wriling on this Work,Order in order to be valid.Additionally,any By sigvwg this Work Order.I hereby Polly acknowledge and agree to the terms of this Order deviation of original Specifications of the services to be performed or additions to those Form as well as the Terms and Conditions on the reverse side fthis Work Order or otherwise specifications by Buyer must be approved by EMSS and may incur additional charges. touched lento,and rnehe,agree m pay all amoums due in-ecurdence with this Work Order. LEONARD ENGINEERING, INC. 251 Mundy Street, Suite C Wilkes-Barre,PA 18702 (570)208-7233 www.LEIdesigns.biz October 17, 2015 Jim Laskowski Endless Mountain Solar Services 288 Kidder Street Wilkes-Barre,PA 18702 Re: Walcutt Residence,34 Japonica Street,Salem,MA Dear Mr. Laskowski, As you requested, I have performed a structural evaluation of the roof framing at the above referenced residence. It is my understanding that solar panels weighing approximately 4 pounds per square foot(psf)are proposed to be installed on the south side of the main house roof. Per your inspection and layout plan,the upper roof is a gable structure framed with 2x6 rafters spaced at 24" on center, sloping at a 10:12 pitch. The rafters span 13"-0" maximum horizontally from the ridge to the exterior bearing walls with intermediate bearing knee walls. The lower roof is a shed structure tied into the main house sidewall and running at,a 3:12 pitch down to a single story rear wall. This roof is framed with 2x10 joists at 16" on center. The Massachusetts Amendment to the 2009 International Residential Building Code snow chart indicates the design ground snow load in Salem is 40 pounds per square foot(psf), which translates to a flat roof snow load of 28 psf. Because of the 10:12 pitch, the roof snow load may be reduced to 21 psf.The roof dead load of the rafters/planking/shingles is approximately LO psf and the addition of the solar panels results in a total dead load of 14 psf. For this evaluation, It was assumed the roof members are typical spruce-pine-fir mix, No. 2 or better. Our calculations indicate the 2x6 rafters are stressed to 156% of their capacity under the full snow load,existing dead load and proposed solar panel weight.Therefore the rafters must be reinforced prior to installing the solar panels. I recommend sistering 2x6 rafters to each of the existing rafters to increase their bending strength. The added members shall extend to within 12" of each end of the existing rafters and shall be attached with 10d nails at 12" on center, top and bottom, staggered. If an existing rafter is split or damaged, an additional member shall be added to both sides of the rafter. If the existing rafters are damaged near the ridge or wall bearing location, at least one sistered member shall extend to the ridge or just past the wall. No other framing areas were included in the scope of this evaluation. The above opinion is based on the above information provided by you and the assumption that the framing members are in sound condition. Any deviations from the above criteria discovered during the course of the work must be immediately brought to our attention. Please call me with any questions. ��NOF414,9 THOMAS G.9c�c Thomas Leonard, P.E. a LEONARD President STRUCTURAL n No 49749 S o �¢ q�}c F�fSTGPE `y�. >= CS-10821-, �q E eJ C CY.AR 1 tt;stlL ,JV ... 394 ELM STREET Czrdner DMA 01=10 ' OG/02/20 i B _- I��ai �_/(i"?O�i'E`iCi:/.rZ'G!/'P.rG°y�Lo"C ip�a_ S-'L'7/.7J{!"✓Gv�'J�t`Ti�' Office of Consumer Affairs and Business Regulation -= = 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 174479 Type: LLC Expiration: 1/28/2017 Tr# 261910 ENDLESS MOUNTAINS SOLAR SERVICES, MICHAEL PITCAVAGE 288 KIDDER STREET - WILKES BARRE, PA 18702 Update Address and return card.Mark reason for change. Address Renewal Employment Lost Card - l(J i'arx riaza - '3ultc -) t / Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 174479 Type: Supplement Card Expiration: 1/28/2017 ENDLESS MOUNTAINS SOLAR SERVICES, -- JAMES LASKOWSKI - - 288 KIDDER STREET WILKES BARRE, PA 18702 Update Address and return card. Mark reason for change. —I, Address Renewal I Employment 1 Lost Card „ 1 U Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 174479 Type: Supplement Card Expiration: 112812017 ENDLESS MOUNTAINS SOLAR SERVICES;, _ ERIC CHARTRAND 288 KIDDER STREET - WILKES BARRE, PA 18702 - .. Update Address and return card. Mark reason for change. [-I Address- ❑ Renewal [_I Employment L] Lost Card SYSTEM SPECIFIACEIONS Endless Mountains ENPHASE M250-60-240V LINE DIAGRAM KWDC2.85KW SOLAR SERVICES KWAC:2.5 KW AC VOLTAGE:240V AC AMPS:SOA AC DISCONNECT SIZE: 30 Amp MODULES/QTY:SOLAR WORLD 285W/10 ENPHASECABLF ® yJ BRED-L21 11■■19 RED-L2 WHITE-NEUTRAL GREEN-GROUND I JUNCTION BOX \ \ ti } fBRAY 6AWG 8 AWGM[r[n PACDISCONNECT . �TERMINATOR CAP IN D I.LEDBLO METER) 10Modules/lOMicfo inverters �UP TO 16M2WS END OF LLEDOE PER BRANCH CIRCUIT TOMETER OR AC DISTRIBUTIONPANELE3REC METER1-2 POLE 20 AMP CIRCUIT BREAKER11 IO AWG WIRE(FROM METER TO INTERCONNECTION)I-Smwwc<a�aveCustomerPanelPER BRANCH CIRCUIT m ETHERNET CONNECTIONTONMSTAFNDFURTNTVT ENVOY COMMUNICATIONS GATEWAY TO BROADBAND ROUTER WwY ROM MAM GEAXFA Note:mere area Ij COMPANY:ENDLESS MOUNTAINS SOLAR SERVICES servce panelspn site. T 288 KIDDER ST Thecustomer's service NEUTU1 GROUNDILKES BARRE PA 18702 (570)820-5990 peveI Is n2 Jon the nghq. 12D VOLV POW ER CABLE DRAWN BY:Shawn Corble AC DISTRIBUTION PANEL Y ORSUBMANCI Murray 125A s.rvlae B CUSTOMER: Jason Wa tuft AWG Panel with IODA 34 Japonica St. Mein Breaker Salem,MA 508-367-5480 Endless Mountains Existing Utility Meter Proposed AC Disco SOLAR SERVICES Proposed Net Meter Proposed REC Meter r - - - - - - _-__,-__ - --- — 1610101 I CusromerMerer i Front �. of House 5 Modules Portrait 138°Azimuth 48° Pitch 5 Modules Portrait C VN COMPANY:ENDLESS MOUNTAINS SOLAR SERVICES SYSTEM SPECIFIACEIONS 288 KIDDER ST --j KWDC 2.85 KW WILKES BARRE PA 18702 (570)820-5990 KWAC:2,5 KW DRAWN BY:Shawn Corbley ® AC VOLTAGE:240V CUSTOMER: Jason Wa cutt AC AMPS:IDA 34 Japonica St. - ���������n�i��l nh AC DISCONNECT SIZE: 30 Amp Salem,MA r MODULES/QTY:SOLAR WORLD 285W/10 ' - 508-367-5480 t Sundul ' �Plu _ - - r SW`285M`ONOs(- 3mmlframe)l i.° REA TUV Power controlled: �.�..� iirvRnanlRne Lowest measuring tolerance in industry WINEvery component is tested to meet 3 times IEC requirements .I Designed to withstand heavy accumulations of snow and ice 1 5unmodule Plus: Positive performance tolerance fed':�. • 25- ear linear performance warrant Y P Y I"—_Ilrs and 10-year product warranty .®!�. Glass with anti-reflective coating ' J World-class quality o�,I1nm.1Ec d»s ' .samhte:YaJEe slIDo /��6.91eW n0<EEd,minan<e.IE[6006&tW V\ Fully-automated production lines and seamless monitoring of the process and mate- o e �,mmo,,,dryjp<e.IK EPnd aDmm<e�eno�.IEc cnm c us rial ensure the qualitythatthe company sets as its benchmark for its sites worldwide. -Pnd'i,i =nlcn UL 1703 f�L xd�d¢I,.eem . SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules that have reaterthan or equal to the nameplate rated power. nnvasan g ❑ NnmeiD C E .�u�.E..�..nEI.P. 25-year linear performance guarantee and extension Of product warranty to 10 years D«c SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course warrantees com MCS` of 25 years, a significant added value compared to the two-phase �❑- mon in the industry,along with our industry-first 10-year product warranty.' 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.sola rworld xom/warranty MADE IN USA OF Its 50la rwodd.cOm AND IMPORTED PARR f Sunmodule% Plus SW 285 MONO (33mm frame) I L REALVALUE- PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/ni NOCT,AM 1.5 Maximumpower p_. 285 Wp Maximum power Pm„ 213A Wp Open circuit voltage V. 39.7V Open circuit voltage V. 364V Maximum power point voltage V.W 31.3 V Maximum power point voltage Vmw 28.7 V Short circuit current I„ 9.84 A Short circuit current 1„ 7.96 A Maximum power point current Imw 9.20A Maximum power point current 1.11 7.43A Module efficiency, qm 17.0% Miner red a ction in efficiency under part,.)load mnddr.ns at 25°C:at 200 W/m;100% (+/-2%)ofthe STC efficiency(1000 W/mi)Is achieved. 'STC:1000 W/m°.25•C,AM 15 1)Measurlog toles nce(i;,,,)traceable to TUV Rhein la nd:+/-2%(TUV Power Controlled). COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells permodule 60 NOCT 46°C Cell type Mona crystalline Cell dimensions 6A7 in x 6.17 in(156.75 x 156.75 ram) Front Tempered glass LEN 12150) Frame Clear anodized aluminum Opera -0.41%/°C Operating temperature -40°C to 85°C Weight 39.7 lbs(18.0 kg) SYSTEM INTEGRATION PARAMETERS 000 W/m' Iu� Maximum system cortege SC II/NEC 00 V Maximum reverse current 25 A 800 W/ma Number of byposs diodes 3 a 600W/ml Design Loads' Two rail system 113 psf downward 64 psf upward Design Loads' Three rail system 178 psf downward 400 W/m' 64 psf upward Design Loads' Edge mounting 178 psf downward 200 W/m' 41 psf upward 100, 'Please refer to the Sunmodule installation instructions forthe details associated with these load cases. Mndulevnitage(Vl V. ADDITIONAL DATA Powersorting' -0 Win/+5 Wp 37.8(961) 1-Box IP65 420 — Module leads PV wire per UL4703 with H4 connectors (106,65)� — 00 i qx�_ Module type(UL 1703) 1 7.12 00.2s (6.6) Glass Low iron tempered with ARC (180.85) • 00.35(9) ^ Compatible with both'Top-Down" and"Bottom"mounting methods o •- Grounding Locations: o —4locations along the length ofthe module in the extended flange. < 130(33) w — LIA 1132 (287.50) V 1.30(33) All units provided are Imperial SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-7102US 12-2014 Enphase®Microinverters Enphase° M250 i ^ r l The Enphase M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage® Cable, the Envoy Communications Gateway", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE -Optimized for higher-power - No GEC needed for microinverter - 4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years 1 enphase® s�j® J E N E R G Y C us Enphase®M250 Microinverter//DATA INPUT DATA(DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA(AC) @208 VAC @240 VAC Peak output power 25b w 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted, reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -400C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 'Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, � ) enphase® visit enphase.com E N E R G Y 0 2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. GreenFasten`" GF1 — Product Guide Installation Instructions i r r 1 L I C fI ry il' 2 3 4 1. Locate the rafters and snap horizontal and vertical lines to mark the installation r 0` 1 position for each GreenFasten flashing. t k 131 � ! "F ,: }'� fit' I' 2. Drill a pilot hole(1/4"diameter)for the lag bolt.Backfil with sealant.* f' t 3. Insert the flashing so the top part is under the next row of shingles and pushed far Ilk enough up slope to prevent water infiltration through vertical joint in shingles. t r q 4. Line up pilot hole with GreenFasten hole. 5. Insert the lag bolt through the EPDM washer,the top compression component f (L-Bracket pictured)and the gasketed hole in the flashing and into the rafter. f . - ' ., ti 6. Torque to 140 inch-pounds ' 7 Consult an engineer or go to www.ecofastensolacmmfnr engineering data. EcoFasten recommends an EPDM mastic. � F _ � I _ If . �F7rI� I i 877-859-3947 Committed to the Support of Renewable Energy ®EcoFasten Solarm All content protected under copyright.All rights resemed.051292012 2.1 fi'J t tl GreenFasten'" GF1 — Product Guide Installation Instructions 1� Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses I 14 " . Slide flashing up under shingles until leading edge engages g engaged Z. Remove flashing and cut"V" notch at marks where nail shafts en a ed nails.Measure remaining distance to adjust upslope. leading edge of flashing the distance desired in Step 1.Notch depth not to exceed 2"length by 1/2"width. Nails beneath shingle A Placement of"V"notch �y s� � r � �X t r J i 3. Reinstall flashing with notched area upslope. 4. Position notched leading edge underneath nail heads as shown. Jjam. Nails beneath shingle Nails beneath shingle I f // Y )Y k � I Jul J877-859-3947 Committed to the Support of Renewable Energy ®EcoFasten Solar*All content protected under copyright All rights reserved.07/122012 2.2 r i VNORAC® SoLARMoujvTT,, (Patent Pending) I SolarMountT shown Flush mounted in landscape (horizontal) mode ® �1 SOLARMouws are the easiest, fastest, and safest way to install a PV array on the roof of virtually any building. Universal —Any 64 Watt or larger, framed PV module Bi-Directional Mounting — Mount your modules in sold.in North America can be mounted using landscape (horizontal) mode, as shown above, or in SolarMount. (See PV Module Compatibility List on the portrait (vertical) mode. If you have limited roof back page.) space, you can even use both orientations in a single installation. Roof Top Assembly— Because of its "top down" clamps, SolarMounts are ideal for use with the new Meets Building Code Requirements—Whether the "plug 'n play" PV modules. An entire array can be roof is pitched or flat, and regardless of the roofing fully assembled and wired where they'll be installed — material, SolarMount will securely attach your PV array on the roof. This eliminates the awkward hazard of to your roof in compliance with U.S Building Codes. lifting partially assembled arrays to the roof, and then (See "Building Code Compliance" on the back page.) mounting and adjusting them on their footings. Quick and Easy Installation—Continuous, dual slotted (See inside for details) SolarMount rails provide the ultimate in adjustability. No more re-drilling holes, or repositioning footings. UNOMAei° SolarMount is a "patent pending"mounting system designed for easy, safe and fast on-the-roof installation of PV modules. No more lifting cumbersome, pre-assembled arrays from the ground to the roof. o. SolarMountT' Dual Slotted Rails SolarMount rails have a Footing Bolt Slot that provides infinite flexibility for positioning SolarMount footings. Module You can always lag directly into a roof member for maxi- Bolt Slot ` mum structural integrity. The Module Bolt Slot P 9 flexibility provides equal flexibili for mount- ing your modules. The result is that SolarMount can mount any module on virtually any roof. Footing Bolt Slot F SollarMount "Togs-Dovywt ModWe Cla yips Modules attach to the rails from the top with unique SolarMount clamps. First, attach the footings to the roof, and the rails to the footings. Then, use the SolarMount clamps to attach the modules to the rails from the top - one module at a time. ' i h i SolanWounts can easily be mounted in either landscape (horizontal array) or portrait(vertical array) mode without Portrait r. ' any special added parts. Mode A variety of SolorMounts are available for mounting from two to as many as nine modules, depending on module r ' ` andsCdpe rx ;r: size. And SolorMounts can be set end to end to create a �b�� ' extended length arrays. (See Splice Kits on the facing page) SOLARMOUNTTiw ® a "L" Footings The standard SolarMount "L" shaped foot is designed to bolt through existing roofing material to the rafter, and to be sealed with an appropriate roofing sealant under each footing. Two vertical mounting holes provide for " ®_ adjustment of the height of the SolarMount rail. Round standoffs (3" and 6" tall) are also available. ° They are installed under the roofing material, and are compatible with Oatey V/4" diameter elastomer collared flashings and other non-collared flashings. (Visit www.oatey.com for details of Oatey flashings) iIt LEIS Standard SolarMount are designed to be flush mounted on a pitched roof. If the roof is flat, or if the roof pitch is too low, tilt legs are available to lift your array to the desired angle to the sun. The maximum angle can vary from 25 to 45 degrees from horizontal, depending on the size and ori- entation of the SolarMount and your PV modules. m Spa0§ee Kits t SolarMounts can be mounted end to end in order to create continuous rows of modules. Simply splice as many SolarMounts together as required. ASE ASEl00, ASE300 AstroPower AP-65/75, APX-90, AP-110/120, AP-150, AP-6105/7105, AP-1106/1206 BP Solar BP270/275, BP585/590, BP2150, MSX-120, SX-75/80/85, SX-110/120 Evergreen EV-94/102 Kyocera KC-70/80/120 Photowatt PW750, PWX1000 Siemens SP65/70/75, SR90/100, SM100/110, SP130/140/150 Uni-Solar US-64 Call UniRac or your PV dealer for any PV module not shown. o9eruvilou—" Component Specfficatoonz :,10 Year Lomked Warranzy m SolarMount Rails and Mounting Clamps, Tilt Legs Unillac, Inc.warrants to the original owner at the original installation site and "L" Shaped Footings— 6061 J6 Aluminum that SolarMounts shall be free from defects in material and workmanship Extrusion for a period of ten(10)years from the earlier of 1)the date the installation is complete, or 2) 30 days after the purchase of the SolarMounts by the ei 3" and 6" Standoffs —Grade 5 Zinc Plated, original owner. This warranty does not cover damage to SolarMounts that Welded Steel occur during shipment, or prior to installation. Fasteners — 304 Stainless Steel If within such period the SolarMounts shall be reasonably proven to be defective,then UniRac shall repair or replace the defective SolarMounts,or part thereof,at UniRac's sole option.Such repair or replacement shall fulfill B litildi ng Code CC4mpfiance all UniRac's liability with respect to this warranty. SolarMounts are designed to comply with the This warranty shall be void if installation of the SolarMounts are not per- Uniform Building Code, 1997, Chapter 16. See formed in accordance with UniRac's SolarMount Installation Guidelines,or if the SolarMounts have been modified,repaired or reworked in a manner Installation Guidelines for details regarding specific not authorized by UniRac in writing, or if the SolarMounts are installed in modules and loading. an environment for which they were not designed. UniRac shall not be liable for consequential, contingent, or incidental damages arising out of use of the SolarMounts. VNMAC° TIMM UniRac, Inc. 2300 Buena Vista, SE, Suite 134 Albuquerque NM 87106 USA Phone: 505.242.6411 Fax: 505.242.6412 e-mail: info@unlrac.com www.uiiirac.com 8/01