26 JACKSON ST - BUILDING INSPECTION �� o2c�BEN y
�
� The Commonwealtlnpft,A��s���}���tt�[�Y1:CG$
� "`"• CITY OF
Boazd of Building Regulations and Standazds
Massachusetts State Buildin C ]ftn g,, SALEM
?��g �i��'[� � L: 2 2 - Revised Mar 2011
Building Permit Application To Construct,Repav, Renovate Or Demolish a
One-or Two-Family Dwelling
This Sec[ion For Official Use Only
�}� Building Permit Number: Date plied:
� .,,w� °1 .28��
Building Official(Print Neme) Signature Date
1
�� SECTION 1:SITE INFORMATION
� 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers
(`^ 26 Jackson St
�a� 1.1 a Is this an accepted street?yes no Map Number Pazcel Number
� 13 Zoning Information: 1.4 Property Dimensions:
Zoning Dishict Proposed Use Lot Area(sq ft) Fro¢tage(ft)
1.5 Building Setbacks(ft)
Froat Yazd Side Yazds Reaz Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.4Q§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
PubGc❑ Private❑ Zone: _ Outside Flood Zone? Municipal� On site disposal system ❑
Check if yes0
SECTION 2: PROPERTY OWNERSHIP'
2.1 Ownerl of Record:
Diane Tache&Gregory Benyue Salem MA 01970
Name(Print) CiTy,State,ZIP
26 Jackson St 978-740-2921 benvue4(a�comcast.net
No.and Street Telephone Email Address
SECTION 3:DESCRIPTION OF PROPOSED WORK=(check all that apply)
New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑
Demoli6on ❑ Accessory Bldg. ❑ Number oFUnits Other Specify: Solar Installation
Brief Description of Proposed Work2: Instanation of an interconnected rooRoo Pv system-ao oanels(9.6kuN
SECTION 4:ESTIMATED CONSTRUCTION COSTS
Item Estimated Cosu: Off"icial Use Only
abor and Materials
1.Building $6646.20 1. Building Permit Fee: $ Indicate how fee is determined:
2.Electrical $�5507.80 ❑Standazd City/Town Application Fee
❑Total Project Cost�(Item 6)x multiplier z
3.Plumbing $ 2. Other Fees: $ -�n /
4.Mechanical (HVAC) $ List: C.k.-�i�Fh �.��_
5.Mechanical (Fire $
Su ression Total All Fees: $
Check No. Check Amount: Cash Amount:
6.Total Project Cost: $22�5a.o0 ❑paid in Full ❑Outstanding Balance Due:
�,���- 1�p-z�
__ �
S�CTIOhi 5: CONSTRUCTION SERVICES
5.1 Construction Supervisar License(CSL)
CS-040622 8/1/17
Stephen A Kelly License Number Exp'uarion Date
Name of CSL Halder
List CSL Type(see below) �
200 Research Dr
No.and Street Type Description
U Uurestricted uildings u to 35,000 cu.ft.)
Wilmington,MA 01887 R Restricted 1&2 Faznil Dwelling
City/Town,State,ZIP M Maso
/1 RC Roofm Coverin
�n WS WindowandSidin
SF Solid Fuel Buming Appliaaces
978-793-7227 iason.boartl an@sunrun.com I 1ngWatian
Tele hone Email address D Demolition
5.2 Registered Home Improvement Contractor(HIC)
180120 10/ia/16
Sunrun Installation Services Inc. HIC Registrarion Number Expiration Date
HIC Company Name or HIC Registrant Name
200 Research Dr iason.boardmanCrD,sunrun.com
No.and Sheet Email address
Wilminqton MA 01887 978-793-7227
Ci /Town,State,ZIP Tele hone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(�)
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes .......... No........... ❑
SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property,hereby authorize Stephen A Kelly/Sunrun Installation Services inc.
to act on my behalf,in all matters relarive to work authorized by this building permit application.
Diane Tache&Greqory Benyue 4/25/16
Print Owner's Name(Electronic Si�ature) Date
SECTION 76:OWNER'OR AUTHORIZED AGENT DECLARATION
By entering my name below,I hereby attest under the pains and penalties of pequry that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
Ste hen A Kell (if 4/25/16
PrintOwner'sorAuthorize genYsName(Electro ' Signature) Date
NOTES:
I. M Owner who obtains a building permit to do lus/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Con[ractor(HIC)Program),will not have access to the azbitration
program or guazanty fund under M.G.L.c. 142A.Other impoRant information on the HIC Program can be found at
www.mass.eov/oca Information on the Consttucrion Supervisor License can be found at www.mass.eov/dps
2. When substanrial work is planned,provide the information below:
Total floor area(sq.ft.) (including gazage,finished basement/attics,decks o�porch)
Gross living area(sq.ft.) Habitable room count
Number of Sreplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"may be substituted for"Total Project CosY'
1
;: CITY OF S��LE.�f, �L�SSACHUSETTS
• BtiQDL�IG DEP�R'i1�.v7
� 13O WASH4�iGTON STREET,3�O FtOOR
TEL (97�745-9595
Fnx(97� 7�10-9846
KI�tgERi.EY DRISCOLL
�tAYOR �IT�to�us Sr.P1ERns
DIREC[OR OF PL:BLIC PROPERTY/BCIID4\G CO�L�RSSIONER
Construction Debris Disposal Affidavit
(required for all demolition and renovarion work)
In accordance with the sixth edition of the State Building Code, 780 CMR section 111.5
Debris,and the provisions of MGL c 40, S 54;
Building Permit# is issued with the condition that the debris resulting from
this work shall be disposed of in a properly ticensed waste disposal facility as de5ned by MGL c
l I 1,S 150A.
The debris will be transpoRed by:
Miller Complete Disposal Service �
(name of hauler)
The debris will be disposed of in :
Miller Complete Disposal Service
(name of facility)
201 North Main St,Middlelon MA 01949
(address of facility)
/�./'��a ��
signahve of permit a plicant
5r/Ls�.cdr G
' �m
dcbrivtT.J�x
�:
`�. �m�� ���
,
OWNER'S AUTHORIZATION FORM
For Permit Application(s)
The sole purpose of this form is to provide Sun Run Inc
with the Necessary permission from the Owner to file Permit Application(s) for
such Project work as agreed upon between the Owner and the Owner's
Authorized Company and its designated subcontractors.
oiane Benyue
Owner's Name:
Solar Project Address:
Signature: ���- ��-
Owner's Authorized Company: Sun Run Inc.
Company's Address: 595 Market St 29"' Floor, San Francisco, CA 94105
Affiliation: Contractor
Applicable License:
State: MA
CSLB�#g69975.N1�13VH070203�0
Massachusetts Electric Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248
Exhibit H -A¢reement Between the Comaanv and the Comnanv's Retail Customer '
(Note: this Agreement is to be signed by the Company's retail Customer where the distributed generation i�stallation and
interconnection will be placed,when the retail Customer is not the owner and/or operator of the distributed generation facility.)
1. Parties. This Ageement between the Company and the Company's Retail Customer("AgreemenY'),dated as of
�(j`Effective Date"of this Agreement)is for a Simplified Process interconnection application and is entered
into,by and between Massachusetts Electric Comoanv(doing business as National Grid),a MassacLusetts Corporation
with a principal place of business at 40 Sylvan Rd,Waltham,MA 02451 (hereinafter referzed to as the"Company"),and
a(n)individual with a principal place of business(or residence)at
("Customer"). (The Company and Customer aze colleclively referred to as the"Parties"). Terms used herein without
defmition shall have the meanings set for[h in Section 12 of the Interconnection Taziff,which is hereby incorporated by
reference.
2. Scope,Purpose,and Related Agreements. This Agreement, in conjunction with the Interconnection Service Ageement
identified in Section 3.2,allows the Interconnecting Customer(as identified in Section 33)to utilize Customer's electrical
facilities to interconnect and operate the Facility in Parallel with Company's EPS. The purpose of the Facility is to serve the
Customer's electrical loads at the location identified in Section 3.1
3. Summary and Description of the ParHes and Location of Generating Facility.
31. The name and address used by Company to locate the Customer or elechic service account where the Facility interconnects
with Company's EPS is:
Attn:
E-mail:
Phone:
Company Account Number:
3.2. The Facility shall be Interconnected with the Company's EPS pursuant to an Interconnection Services Agreement between
Company and Interwnnecting Customer,its successors or assigns("Interconnecting Customer")dated
("Interconnection Service AgreemenY').
3.3. Interconnecting Customer's contact information:
A�: SUnrUn, InC.
595 Market St, 29th FL
San Francisco CA 94105
E-maz�: nem-srs@sunrun.com
Phone: (g55) 478-6786
4. Customer Acknowledgement and Obligations.
4.1. Customer acknowledges that it has authorized the Facility to be installed and operated by Interconnecting Customer in
accordance with Company's Interconnection Tariff in or adjacent to Customer's premises. Such Facility shall be used to
serve all or a portion of Customer's electrical loads associated with the electric service provided by Company at the
location identified in Section 3.1 above. Customer shall be solely responsible for the tenns of any agreement between it
and Interconnecting Customer.
41. Customer shall be solely responsible for any chazges incurred under Company's electric service tariffs,and any other
regulations and laws goveming the provision of electric services. Customer aclmowledges that it has been made aware
of the charges and conditions related[o the operation of the Facility and that the performance or lack of performance of
the Facility may affect the rates and charges billed by Company for the electric power delivered to Customer. Copies of
such tariffs aze available by request to Company or on the Company's web site.
4.3. Any amount to be paid,or refunded to,Company for the services received by Customer as a result of the Interconnecting
Customer failing to operate the Facility in accordance with the terms of the representations and warranties made under
the Interconnection Service Agreement sha71 be paid to Company by the Customer in acwrdance with Company's
electric taziffs.
E�chibit H for Simplified Application (Signing Customer°s�itials:���DPage 1 of 3
Massachusetts Electric Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248
` Exhibit H -Aereement Between the Comaanv and the Comaanv's Retail Customer
4.4. Customer shall provide access as necessary to the Customer's premises for Company personnel,conhactors or agents to
perform Company's duties under the Interconnection Tanff. The Company shall have access to the disconnect switch of
the Facility at all times.
5. Terms and Termination.
5.1. This Ageement shall become effecUve as of the date referenced in Section 1. The Agreement shall continue in fiill force and
effect until the eazliest date that one of the following events occurs:
5.1.(a) The Parties agree in writing to terminate the Agreement.
5.1.(b) At 12:01 A.M. on the day following the date the Customer's electric service account through which the Generating
Facility is interconnected to Company's EPS is closed or teiminated.
5.1.(c) At 12:01 A.M. on the 31st day following the date the Interconnection Service Ageement is terminated.
5.1.(d) At 12:01 AM. on the 61st day after Company provides written Notice pursuant to Section 7 below to the Customer
that Customer is not in compliance with the terms of this Agreement.
6. Limitation of Liability.
6.1. Each Party's liability to the other Party for any loss,wst,claim,injury,liability,or expense, including court costs and
reasonable attomey's fees,relating to or azising from any act or omission in its performance of this Ageement,shall be
limited to the amount of direct damage or liability actually incurred. In no event shall either Party be liable to the other
Party for any indirect,incidental,special,consequential,or punitive damages of any kind whatsoever.
6.2. Company shall not be liable to Customer in any manner,whether in tort or contract or under any other theory,for loss or
damages of any kind sustained by Customer resulting from existence of,operation of,or lack of operation of the Faciliry,
or termination of the Interconnection Service Agreement,provided such termination is consistent with the terms of the
Interconnection Service Agreement,except to the extent such loss or damage is caused by the negligence or willful
misconduct of the Company.
7. Notices.
7.1. Any written notice,demand,or request required or authorized in connection with this Agreement("I�Iotice")shall be deemed
properly given on the date actually delivered in person or five(5)business days after being sent by certified mail,e-mail
or�vc with co�rmation of receipt and original follow-up by mail,or any nationally-recognized delivery service with
proof of delivery,postage prepaid,to the person specified below:
If to Company: National Grid
Attn: Distributed Generation
40 Sylvan Rd
Waltham,MA 02451
E-mait Distributed.Generafion@nationalgrid.com
If to Customec
Attn: .
E-mail:
Phone:
7.2. A Party may change its address for Notices at any time by providing the other Party Notice of the change in accordance with
Section 7.1.
7.3. The Parties may also designate operating representatives to conduct the daily communications,which may be necessary or
convenient for the administration of this Agreement. Such designations,including names,addresses,and phone ntunbers
may be communicated or revised by one Pady's NoGce to the other.
S. Release of Data. Company shall maintain co�dentiality of all Customer confidential and proprietary infonnation
except as otherwise required by applicable laws and regulations,the InterconnecUon Taziff,or as approved in
writing by the Customer.
9. Assignment. Except as provided herein,Customer shall not voluntarily assign its rights or obligations,in whole or in part,
under this Agreement without Company's written consent. Any assignment Customer purports to make without Company's
written consent shall not be valid. Company shall not unreasonably withhold or delay its consent to Customer's assignment
of this Agreement. Notwithstanding the above,Company's consent will not be required for any assignment made by
Customer to an Affiliate or as collateral security in connection with a financing transaction.In all events,the Customer will
Enhibit H for Simplified Application (Signing Customer's�i[ialsi�Page 2 of 3
Massachusetts Electric Company 8c Nantucket ElecUric Company(d/b/a National Grid) M.D.P.U. 1248
Exhibit H -Aereement Between the Comaanv and the Comoanv's Retail Customer `
not be relieved of its obligations under this Agreement unless,and until the assignee assumes in writing all obligations of this
Agreement and notifies the Company of such assumption.
10. Non-Waiver. None of the provisions of this Ageement sttall be considered waived by a Party unless such waiver is
given in writing. The failure of a Party to insist in any one or more instances upon strict performance of any of the
provisions of this Ageement or to take advantage of any of its rights hereunder sha71 not be construed as a waiver of
any such provisions or the relinquishment of any such rights for the future,but the same shall continue and remain in
fiill force and effect.
11. Governing Law,Jurisdiction of Commission,Inclusion of Company's Tariffs,Defined Terms.
11.1. This Ageement shall be interpreted,govemed,and construed under the laws of the Commonwealth of Massachusetts
without giving effect to choice of law provisions that might apply to the law of a different jurisdiction.
11.2. The interconnection and services provided under this Agreement shall at all times be subject to terms and conditions set
forth in the tariffs applicable to the electric service provided by Company. Copies of such tariffs are available at the
Company's web site or by request to Company and aze incorporated into this Ageement by this reference.
11.3. Norivithstanding any other provisions of this Agreement,Company shall have the right to unilaterally file with the
Deparhnent,pursuant to the DepartmenYs rules and regulations,an application for change in tariffs,rates,charges,
classification,service or any agreement relating thereto.
11.4. When initially capitalized,whether in the singulaz or in the plural,the tenns used herein shall have the meanings
assigned to them either in this Agreement or in the Interconnection Taziff.
12. Amendments and Modifications. This Agreement can only be amended or modified by a written agreement signed by both
Parties.
13. EnHre Agreement. This Agreement,including any attachments or appendices,is entered into pursuant to the
Interconnection Service Agreement and the Interconnection Taziff. Together this Agreement,the Intemonnection Service
Agreement,and the Interconnection Taziff represent the entire understanding between the Parties,their agents,and
employees as to the subject matter of this Agreement. Each pariy also represents that in entering into this Ageement,it has
not relied on any promise, inducement,representation,wazranty,agreement or other statement not set forth in this Agreement
or in the Company's Interconnection Taziff.
14. Indemnification. Except as the Commonwealth is precluded from pledging credit by Section ] of Article 62 of the
Amendments to the Constitution of the Commonwealth of Massachusetts,and except as the Commonwealth's cities and
towns aze precluded by Section 7 of Article 2 of the Amendments to the Massachusetts Constitution from pledging their
credit without prior legislative authority,Customer and Company shall each indemnify,defend and hold the other, its
directors,officers,employees and agents(including,but not limited to,Affiliates and contractors and their employees),
havnless from and against all liabilities,damages,losses,penalties,claims,demands,suits and proceedings of any nature
whauoever for personal injury(including death)or property damages to unaffiliated third par[ies that arise out of or are in
any manner connected with the performance of this Agreement by that Par[y except to the extent that such injury or damages
to un�liated third parties may be attributable to the negligence or willful misconduct of the Party seeking indemnification.
15. Signatures. IN WIT'NESS WHEREOF,the Parties hereto have caused rivo(2)originals of this Agreement to be executed
under seal by their duly authorized representatives.
National Grid:
oiane aenyue
Name: Name:
Title: TiUe:
3/24/2016
Date: Date:
Lgnature: 11��� �� Signahue:
Exhibit H for Simplified Application Lgning Customer's�i[ials::���Page 3 of 3
Massachusetts Electric Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248
` Schedule Z—Additional Information Required for Net Metering Service I
Please fill out the form completely(and initial th�bottom of each page). !I
Host Customer Name: Telephone: '
Address of Facility: �
Billing Account Number: II
Meter Number: Application ID Number: ' '
The Host Customer is a(check any that apply): ❑ Municipality ❑ Other Govemmental Entity
If so, submit certification provided by the DPU when obtained. Public Classification ID: '
A) Is the Host Customer applying for net metering service an electric company,generation company, aggregator, ',
supplier,energy mazketer,or energy broker,as those terms aze used in M.G.L. a 164, §§ 1 and IF and 220 C.M.R. j
§11.00? ❑■ No ❑Yes(you aze not eligible for net metering service) I
NOTE:Definitions are.• I
"Electric company"means a corporadon organized under the laws of the commomvealth for the purpose of making by ',
means of water power, steam power or atherwise and for selling, transmitting, distribudng, transmitting and selling, or I
distributing and selling, electriciry within the commomvealth, or authorized by special act so to do, even though
subsequendy authorized to make or sell gas;provided, however, that electric company shall not mean an alternative '
energy producer;provided further, that a distribution company shall not include an entiry which owns or operates a plant
or equipment used to produce electricity, steam and chilled water, or an affiliate engaged solely in the provision of such
electnciry, steam and chilled water, where the electriciryproduced by such entiry or its a,�liate isprimarily for the benefit
of hospitals and nonprofit educational institutions, and where such plant or equipment was in operation before January 1,
1986; andprovidedfurther, that electric company shall not mean a corporadion only transmitting and selling, or only
transmitNng, electricity unless such corporation is affiliated with an electric company organized under the laws of the
commomvealth for the purpose of distribudng and selling, or distributing only, electricity within the commomvealth. G.L.
c. 164, §I.
"GeneraHon company"means a company engaged in the business ofproducing, manufacturing or generating electricity
or related services or products, including but not limited to, renewable energy generation attributes for retail sale to the
public. G.L. c. 164, §1.
"Aggregator"means an emity which groups together electriciry Customers for retail sale purposes, except for public
entities, quasi public entities or authorities, or subsidiary organizations thereof, established under the laws of the
commomvealth. G.L. c. 164, ,¢l.
"Supplier"means any supplier ofgeneradon service to retail Customers, induding power marketers, brokers and
marketing affiliates of distribudon companies, except that no electric company shall be considered a supplier. G.L. c. 164,
,¢1.
"Host Customer"means a Customer with a CJass I, II, or II Net Metering Facility that generates electriciry on the
Customer's side of the meter.
"Nameplate Capacity"means,for the purposes of calculating net metering capacity only, the nominal capacity of a
system that reflects normal operaring conditions, and not marimum operating conditions
For the terms "energy marketer"and "energy broker,"please use the definidon for "Electricity Broker,"which
means an entity, including but not limited to an Aggregator, which facilitates or otherwise arranges for the purchase and
sale of electriciry and related services to Retail Customers, but does not sell electricity. Public Aggregators shall not be
considered Electricity Brokers. 220 C.M.R. 11.02.
�/�7
Massachusetts:http//www national¢ridus com/masselectric/home/ener�veff/distributed seneration asp os[Customer niiials',
Page 1 of 4
Massachusetts Electric Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248
Schedule Z—Additional Information Required for Net Meterin¢ Service '
B) If applying for Net Metering as an Agricultural Net Metering Facility, please answer the following questions:
1) Is the Agriculhual Net Metering Facility operated as part of an agricultural business?
❑ Yes ❑No(the facility is not eligible for Net Metering as an Agricultural Net Metering Facility)
2) Has the Commissioner of the Department of Agriculture recognized the business as an agriculhual business?
❑ Yes ❑No
3) Is the Agricultural Net Metering Facility located on land owned or controlled by the agricultural business mentioned
in Item B.1 above?
❑ Yes ❑No(the facility is not eligible for Net Metering as an Agricultural Net Metering Facility)
4) Is the energy from the Agricultural Net Metering Facility used to provide electricity to metered accounts of the
agricultural business mentioned in Item B.1 above?
❑ Yes ❑No(the facility is not eligible for Net Metering as an Agricultural Net Metering Facility)
C) If applying for neighborhood net metering, please answer the following questions:
1) Are all participants served by the same distribution company? ❑Yes ❑No
2) Are all participants served by the same ISO-NE load zone? ❑Yes ❑No
3) Do all participants reside in the same municipality? ❑Yes ❑No
NOTE:If any of the answers to the questions in Item C are no, then the faciliry is ineligible for neighborhood net metering
unless granted an exception by the Department ofPublic Utilities under 220 C.M.R. §18.09(6).
D) Please indicate how the Host Customer will report to the Company the amount of electricity generated by the net
metering facility. The information is due twice each year: (1)by January 31 for the prior year's generation; (2)by
September 30 for the year-to-date generation:
❑ Provide the Company access to their ISO-NE GIS account
❑■ Provide the Company access to their metering or inverter data
❑ Provide the Company with a report in writing of the generation by Januazy 31 and again on September 30 each yeaz
E) For any Billing Period in which the Host Customer eams Net Metering Credits, please indicate how the Distribution
' Company will apply them:
❑■ Apply all of the Net Metering Credits to the account of the Host Customer(Skip Items F and G)
❑ Allocate all the Net Metering Credits to the accounts of eligible Customers(Class I and II Net Metering Facilities
skip Item F)
❑ Both apply a portion of the Net Metering Credits to the Host Customer's account and allocate a portion to the
accounts of eligible Customers(Class I and II Net Metering Facilities skip Item F)
F) If the Host Customer has a Class III Net Metering Facility,please indicate below the range that best represents the
number of eligible Customer accounts to which Net Metering Credits would be allocated. Alternatively,please
complete Item G. This information will allow the Company to exercise its option to purchase Net Metering Credits
from the Host Customer rather than allocating such credits.
The Company will notify the Host Customer within 30 days of the filing of Schedule Z whether it will allocate or
purchase Net Metering Credits. If the Company elects to purchase Net Metering Crediu,the Company will render
payment by issuing a check to the Host Customer each Billing Period,unless otherwise agreed in writing by the Host
Customer and Company. If the Company elects to allocate Net Metering Credits,the Host Customer must complete
Item G and submit the revised Schedule Z to the Company.
❑Allocate Net Metering Credits to fewer than 50 eligible Customer accounts(Skip Item G)
❑ Allocate Net Metering Credits to 100 or fewer eligible Customer accounts(Skip Item G)
❑ Allocate Net Metering Credits to more than 100 eligible Customer accounts(Skip Item G)
G)Please state the total percentage of Net Metering Credits to be allocated.
% Amount of the Net Metering Credit being allocated. The total amount of Net Metering Credits being allocated
sha11 not exceed 100 %. Any remaining percentage will be applied to the Host Customer's account.
Massachusetts: htto://www.nationaletidus.com/masselectric/home/enereveff/distributed�eneration.asQ Q-Iost Customer IniYials'�
Page 2 of 4
Massachusetts Electric Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248
' Schedule Z—Additional Information Reauired for Net Meterine Service
Please identify each eligible Customer account to which the Host Customer is allocating Net Metering Credits by
providing the following information(attach additional pages as needed):
NOTE:If a designated Customer account closes, the allocated percentage will revert to the Host Customer's account,
unless otherwise mutually agreed in writing by the Host Customer and the Company.
Customer Name:
Service Address:
Billing Account Number: '
If public entity,DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Customer Name:
Service Address:
Billing Account Number:
If public entity, DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Customer Name:
Service Address:
Billing Account Number:
If public entity, DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Customer Name:
Service Address:
Billing Account Number:
If public entity,DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Customer Name:
Service Address:
Billing Account Number:
If public entity,DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Customer Name:
Service Address:
Billing Account Number:
If public entity,DPU Public Classification ID:
Amount of Net Metering Credit Allocated: %
Total Net Metering Credit allocation on this page: 0%(automatic calculation)
(If this is an additional page attached to the Schedule Z, indicate: Additional Page of_)
i/�7
Massachusetts: htt�//www nationaleridus com/masselectric/home/ener�veff/distributed seneration asp (Host Customer.Initial�
Page 3 of 4
Massachusetts Elechic Company&Nantucket Electric Company(d/b/a National Grid) M.D.P.U. 1248 .
Schedule Z—Additional Information Required for Net Meterine Service
H) The Company may elect to seek to obtain capacity payments from ISO-NE for the electricity generated by Class II
and III Net Metering Facilities. The Company will notify the Host Customer within 30 days of the filing of Schedule
Z whether it will assert title to the right to seek those capacity payments. If the Company elects to assert title to those
capacity payments,the Company will include any capacity payments received from ISO-NE in the Company's annual
Net Metering Recovery Surcharge reconciliation.
I) The terms of this Schedule Z shall remain in effect wiless and until the Host Customer executes a revised Schedule Z
and submits it to the Company. Unless otherwise required herein or mutually agreed to in writing by the Host
Customer and the Company, a revised Schedule Z shall not be submitted more than twice in any given calendaz yeaz.
J) A signature on the application sha11 constitute certification that(1)the Host Customer has read the application and
knows its contents; (2)the wntents are true as stated,to the best knowledge and belief of the Host Customer;and(3)
the Host Customer possesses full power and authority to sign the application.
�/iAln.f- f�f,bt.�Ul, I
{ O�a�.uawu�ci.��ua�ui0� '�,
Diane Benyue ��,
Host Customer(Print)
3/24/2016
Date
��
Massachusetts:htto://www.nationalp.ridus.com/masselectric/home/eneravefF/distributed�eneration.asp (Host Customer.Iniiials:�_�
Page 4 of 4
' Rocu�
, . fisecuaae
�,.'..�.� - �- ..�,�..^�- ��._
Certificate Of Completion
�_ ._� _ _. . _ ---___ _ - — — __ —
Envelope Id:866A26678972401 F919E53D027878FCA �Status:Completed
Subject:[26 Jackson Street,Salem MA 01970]-Please Docusign Your Sunrun Interconnection Documents
Source Envelope: �
Document Pages:8 Signatures:3 Envelope Originator:
CeAificate Pages:4 Initials:7 Lgcy Power
AutoNav:Enabled 45 Fremont Street
Envelopeld Stamping:Disabled San Francisco,CA 94105
Time Zone:(UTC-08:00)Pacific Time(US&Canada) Igcysupport@sunrun.com
IP Address:70.192.4.146
Record Tracking ���
Status:Original " Holder.Lgcy Power Location: DowSign
3/24/2016 4:15:45 PM Igcysupport�sunrun.com
Signer Events _ Signature Timestamp v P j �
Diane Benyue n �,,1.I,.. Sent:3Y14/20164:15:46 PM
benyue4(daol.com v� V`^"7'^" Vewed:3/24/20164:17:30PM
Security Level: Email,Account Authentication Signed:3/24/2016 4:18:12 PM
(None)
Using IP Address:70.192.4.146
Signed using mobile
Electronic Record and Signature DisGosure:
Accepled:3124/2016 4:�730 PM
ID:645797e8[10634d35-b7ca-0294e70eed37
In Person Slgner Events Signature Timestamp ��_�
Editor Delivery Events Status Timestamp �T �
Agent Dellvery Events Status Timestamp i �v_��
Intermediary Delivery Events Status Timestamp _�
Certified Delivery Events Status Timestamp �
Carbon Copy Events � Status Timestamp �
Notary Events ! � Timestamp i�� ��
Envelope Summary Events Status Timestamps
�
� -- - ---— --- - —_
Envelope Sent Hashed/Encrypted 3/24/2016 4:15:47 PM
Certified Delivered Security Checked 3/24/2016 4:17:30 PM
Signing Complete Security Checked 3/24/2016 4:18:13 PM
Completed Security Checked 3/24/2016 4:78:13 PM �
Electronic Record and Signature Disclosure —��
Electmroc Recortl antl Signature DisGosure created on:8/7/2013 5:17:58 PM �
Parties agreed to:Diane Benyue �
CONSUMER DISCLOSURE
From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you
certain written notices or disclosures. Described below are the terms and conditions for
providing to you such notices and disclosures electronically through the DocuSign, Ina
(DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW
CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION
ELECTROIVICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND
CONDTI'IONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE'
BUTTON AT THE BOTTOM OF TffiS DOCUMENT.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available
electronically to you by us. You will have the ability to download and print documents we send
to you through the DocuSign system during and immediately after signing session and, if you
elect to create a DocuSign signer account, you may access them for thirty (30) days after such
documents aze£ust sent to you. Afrer such time, if you wish for us to send you paper copies of
any such documents from our office to you, please request delivery of such paper copies from us
i by following the procedure described below.
Withdrawing your coasent
If you decide to receive notices and disclosures from us electronically, you may at any time
change your mind and tell us that thereafter you want to receive required notices and disclosures
only in paper format. How you must inform us of your decision to receive future notices and
disclosure in paper format and withdraw your consent to receive notices and disclosures
electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the
speed at which we can complete certain steps in transactions with you and delivering services to
you because we will need first to send the required notices or disclosures to you in paper format,
and then wait until we receive back from you your acknowledgment of your receipt of such
paper notices or disclosures. To indicate to us that you aze changing your mind, you must
withdraw your consent using the DowSign a€"Withdraw Consenta€TM form on the signing page
of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn
your consent to receive required notices and disclosures electronically from us and you will no
longer be able to use the DocuSign system to receive required notices and consents electronically
from us or to sign electronically documents from us.
All notices and disclosures will be sent to you electronically
Unless you tell us otherwise in accordance with the procedures described herein, we will provide
electronically to you through the DocuSign system all required notices, disclosures,
` authorizations, acknowledgements, and other documents that aze required to be provided or
made available to you during the course of our relationship with you. To reduce the chance of
you inadvertently not receiving any no6ce or disclosure, we prefer to provide a11 of the required
notices and disclosures to you by the same method and to the same address that you have given
us. Thus, you can receive all the disclosures and notices electronically or in paper format through
the paper mail delivery system. If you do not agee with this process, please let us know as
described below. Please also see the pazagaph immediately above that describes the
consequences of your elecung not to receive delivery of the nouces and disclosures
electronically from us.
How to contact Sunrun Inc.:
You may contact us to let us know of your changes as to how we may contact you electronically,
to request paper copies of certain information from us, and to withdraw your prior consent to
receive notices and disclosures electronically as follows:
To contact us by email send messages to: customercare@sunrun.com
You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105
or by phone at 1-855-478-6786.
To advise Sunrun Inc. of your new e-mail address
To let us know of a change in your e-mail address where we should send notices and disclosures
electronically to you, you must send an email message to us at customercaze@sunrun.com and in
the body of such request you must state: your previous e-mail address, your new e-mail address.
We do not require any other informaUon from you to change your email address.
In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email
address to be reflected in your pocuSign account by following the process for changing e-mail in
the DocuSign system.
To request paper copies from Sunrun Inc.
To request delivery from us of paper copies of the notices and disclosures previously provided
by us to you electronically, you must contact us by(a) sending us an e-mail to
customercaze@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San
Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request
you must state your e-mail address, full name, US Postal address, and telephone number.
To withdraw your consent with Sunrun Inc.
To inform us that you no longer want to receive futwe notices and disclosures in electronic
format you may:
i. decline to sign a document from within your pocuSign session, and on the subsequent
page, select the check-box indicating you wish to withdraw your consent, or you may;
ii. contact us by(a) sending us an email to customercaze@sunrun.com, (b) writing to us at
Sunrun Inc.,45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or(c) calling us at
1-855-478-6786, and in connection with your request you must state your e-mail, full
name, US Postal Address, and telephone number. We do not need any other information
from you to withdraw consent.. The consequences of your withdrawing consent for online
documents will be that transac6ons may take a longer time to process..
Re uired hardware and software
Operating Systems: WindowsA� 2000, WindowsA�XP, Windows
VistaA�; Mac OSA� X
Browsers: Final release versions of Internet ExplorerA�
6.0 or above (Windows only); Mozilla Firefox
2.0 or above (Windows and Mac); Safaria„¢
3.0 or above ac onl )
PDF Reader: AcrobatA� or similar softwaze may be required
to view and rint PDF files
Screen Resolution: 800 x 600 minimum
Enabled Security Settings: Allow per session cookies
J
** These minimum requirements are subject to change. If these requirements change, you will be
asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and
browsers aze not supported.
Notices r
Any notice or other communication to be made hereunder, even if otherwise required to be in
writing under other provisions of this Consent or any other documents or agreements that have
been provided to you in connection with this Consent, may alternatively be made in an electronic
record transmitted electronically to the electronic addresses provided by you. Any notice or other
communication made in electronic form will have the same legal effect and enforceability as if
made in non-electronic form.
Acknowledging your access and consent to receive materials electronically
To confirm to us that you can access this information electronically, which will be similaz to
other electronic notices and disclosures that we will provide to you, please verify that you were
able to read this elech�onic disclosure and that you also were able to print on paper or
electronically save this page for your future reference and access or that you were able to e-mail
this disclosure and consent to an address where you will be able to print on paper or save it for
your future reference and access. Further, if you consent to receiving no6ces and disclosures
exclusively in electronic format on the terms and conditions described above, please let us know
by clicking the a€"T agreea€TM button below.
By checking the a€"I agreea€TM box, I confirm that:
• I can access and read and have accessed, read and understood the terms of this
ELECTRONIC CONSENT TO ELECTRONIC RECEII'T OF ELECTROIVIC
CONSiTMER DISCLOSURES document; and
• I can print on paper the disclosure or save or send the disclosure to a place where I can
print it, for future reference and access; and
• Until or unless I noUfy Sunrun Inc. as described above, I consent to receive from
exclusively through electronic means all notices, disclosures, authorizations,
acknowledgements, and other documents that are required to be provided or made
available to me by Sunrun Inc. during the course of my relationship with you.
Entire Agreement Provision
This agreement and the consumer disclosure statement executed by the customer in conjunction
with and simultaneously with its review and acceptance of the [erms set forth herein consti[ute
the entire agreement between the parties with respect to the subject matter hereof and supersede
any prior understandings, agreements, or representarions by or between the parties, written or
oral, to the extent they relate in any way to the subject matter hereof.
-� �m
,�,> ��;.:�� y�ER ��z�;�--"
' �A`SSA�4�U�SE'I?T;�_ ��ENS ^
M � ��:��-
. �� a � ,d�.i:...�F �� 't . «e �
y7^p"
. I f � y � �,,•° '�p'
^=i `e� Ih'MMV�ER
��` ,ia� � -.o�6M i,dF�af
,, ,- , ,or�a�b���Hoati� �05Q'6�g2��
" �. ���08 U1 2Q20 W�06 q���9`� -
' � <�' ...� � w+s x$+' .�j�ts��� �e AF�{'�;�t� 1�. '�
� � ,w. MA� �nr"� ,y�M .�� 1�-�.
� ' a
� �� ,��{'('�LL.�.�; ,�,.-» �� :��
�:6TEPy6 A ��F{� '} � _
efBPARKWAYRD �
. SI'ONEIWM,.hL4 02'180•2821
� � .�•���..
' " �' �i` p6om.to-mi�wnov.isaga =>F.o
�' �fi ��F ' , . ��pr�kyJt+`", .
.L� .�. r - . . � � �
� � Massachusetts Departaa�entof Pubiic Safety .
��� Boasd of'Building Regulatdons and Standards
License: CS-040S22 � �
Construction Supe�visor
�� 1 i 6� �� w. :
h �
STEPMEN A KELCY :.
76 PARKWAX ROAQ, o F^� s�
STONEHAM MA.D216� -
r � � �
� `��� �
�y i'
•
/���r �.� �4Y tt
�.�n l/L.— Ezpiration:
Commissioner 0810111017
� �T� �� ��� �
; , Office of Consumer Affairs �hd Business Re ulation
� o g
;° 10 Park Plaza - Suite 5170
Boston, Massachusetts 02116
Home Improvement�,CQntraetor Registration
�
�~��"" ` Registration: 180120 '
� ---���=- --=�,-,
,�� � z-��:��s�� Type: Supplement Card
' '+ —`"� ��' i'_ Expiration: 10/14/2016
SUNRUN INSTALLATION SERVIC�SEIIVC--' --: !;�; �
STEPHEN KELLY '�'I '— r ���
775 FIERO LANE SUITE 200 ' � � ����
SAN LUIS OBISPO, GA 93401 tb� �- 1-
''� �.f, /
Cyr J"� � �, \`,��
' { � ?:/ Update Address and return card. Mark reason for change.
"�-�=:.
scn i r, 2oM-osm � Address � Renewal � Employment � Lost Card
Ul2e TOOanunzavuue2GG1L o�Uv6aaa2CfZeGueCt�
�ce of Consumer Atfeirs& Business Regulation License or registration valid for individul use only
E IMPROVEMENT CONTRACTOR before the expiration date. If found return to:
a `,5,. '� Office of Consumer Affairs and Business Regulation
gistration:�1=80:120�--� Type: �0 Park Plaza- Suite 5170
_ Expvahq'h; �Ol�4/�tk'#���/"„ Supplement Car+i Boston,MA 02116 ' -
SUNRUN INSTALLATI(�N 3ERV.IC6�S INC.
(%l t =�..'-X�-`7 I:i; .
�:�,�:f��:._=d,:',J
STEPHEN KELLY `��,���' �/'�� . >
775 FIERO LANE $UITE 2p0 r"� / , �.,,t v ;a;4;Y--_ �
SAN LUIS OBISPO, CA 93401 Undersecretary Not valid without si ture
� The Commonweakh of Massachusetts
Department of Industrial Accidents
1 Congress Street, Suite 100
Boston,MA 02114-2017
www.mass.gov/dia
R'orkers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers.
TO BE FILED WITH THE PERMITTING AUTHORITY.
Applicant Information Please Print Leeiblv
Name (ausiness/Organization/[ndividuaq:Sunrun Installation Services, Inc. II
Address:��5 Fiero Lane, Suite 200 I
City/State/Zip:San Luis Obispo, CA 93401 Phone #:978'549-9438 II
Are you an employer?Check the appropriare box: ��,
Type of project(required): ,
I.�I am a employer with 35 employees(full and/or part-time).' 7. �New construction i,
2.❑I am a sole proprietor or partnership and have no employees working for me in $. �RemOd0ling '�.
any capaciTy.[No workers'comp.insuranw required.] ,
9. ❑Demolition �
3.�I am a homeowner doing all work myself.[No workers'comp.insurance required.]t
10 �Building addition
4.�I am a homeowner and will be hiring contractors to conduct all work on my property. I will
ensure that all contracrors either have workers'compensat�on msurance or are sole 11.�Electrical repairs or additions
proprietors wi[h no employees.
12.�Plumbing repairs or additions
5.�I am a general wntractor and I have hired the sub-contractors listed on the attached sheet 13.�Roof repairs
These subconvacrors have employees and have workers'comp.insurance.2
6.�We are a corporation and i[s officers have exercised their righ[of exemption per MGL c.
14.�✓ Other Rooftop Solar
152,§I(4),and we have no employees.[No workers'comp.insurance required.]
'Any applicant that checks box#I must also 611 out the section below showing their workers'compensa[ion policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside con[ractors must submit a new affidavit indicating such.
3Contrac[ors that check this box must attached an additional sheet showing[he name of[he sub-contrac[ors and state whe[her or no[Ihose en[ities have
employees. If[he sub-contractors have employees,[hey must provide their workers'comp.policy number.
/am an emp[oyer that is providing workers'compensation insurancejor my emp[oyees. Below is the po[icy and job site
injormation.
Insurance Company Name:Zurich American Insurance Company
Policy#or Self-ins.Lic.#:WC013696001 &WC013696101 Expiration Date: 10/01/2016
Job Site Address:26 JaCkson St Ciry/State/Zip:Salem MA 01970
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00
and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a
day against the violatoc A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance
coverage verification.
7 do hereby certiJy under[he pains and penalties ofpery'ury that the injormation provided above is true and correct.
SiQnature� r�:��L�'�+- ��� Date: Y�-t S�1l�7('c
Phone#:978-549-9 8
Ojficia/use only. Do not write in[his area,to be completed by ciry or town official.
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/1'own Clerk 4.Electrical[nspector 5.Plumbing[nspector
6.Other
Contact Person: Phone#:
� � DATE�MMIDDIYYYY)
A�� CERTIFICATE OF LIABILITY INSURANCE „nono,s
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGAT7VELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER�S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certifcate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorvement�s).
PRODUCER � TA
MARSH RISK&INSURANCE SERVICES NAME:
345 CALIFORNIA STREET,SUITE 1300 PHONE Fax
C o A/C No:
CALIFORNIA LICENSE N0.0437153 E�MAIL
SAN FRANCISCO,CA 94104 nooRess:
INSURE 5 AFFORDINGCOVERAGE NAIGM
1049fi0339-STND-GAX-1516 iNsuaea n:�ames River Insurance ComDany 12203
INSURED INSIIRER B:N/A NIA
$IlONO�05�21�21W0$BNICCS,11IC.
and REC Solar,Inc. iNsuaea c:Houston Casualty Company 42374
775 Fiero Lane,Suite 200 INSORER D:
San Luis Obispo,CA 93401
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: SEA-003015622-01 REVISION NUMBER:5
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTVNTHSTANDING ANV REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CER7IFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED eY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAV HAVE BEEN REDUCED BY PAID CLAIMS.
INSR rypE OP INSURANLE A�OL SUBR pOLICY NUMBER MM/DD/YVYY MM�OI V�YY - LIMITS
LTR
A X COMMERCIALGENERALLIABILITY OOOfi4124� �Oro�I��5 101�lI2O7fi EqCHOCCURRENCE $ 1,OOO,WO
CLAIMS-MADE �OCCl1R PREMISES EaEoccurrence a 300,000
ME�EXP(Any ane person) 5 10,��
PERSONALBA�VINJl1RY $ ������
GEN'LAGGREGATELIMITAPPLIESPER: GENERALAGGREGATE $ Z������
POLICV� PR�- � LOC PRODUCTS-COMP/OPAGG $ 2,000,000
x JECT
x o7nER�. Host Li uor Liabilil TOTAL POLICY LIMIT g 10,000,000
AUTOMOBILELIABILITV COMBINEDSINGLELIMIT $
Ea accitlent
ANV AUTO BODILY INJURY(Pe�pe�son) E
ALLOWNED SCHE�ULED BODILVINJURV(Peraccitlent) S
AUTOS AUTOS
NON-0WNE� PROPERTY DAMAGE $
HIREDAUTOS AUTOS Pe�accitlen�
$
� UMBRELLALIAB X OCCUR HI5XCSOPJYOJ 101O'IIPO�5 ������p�s EACHOCCURRENCE $ 10,000,000
X EXCESSLIAB CLAIMS-MADE AGGREGATE $ 10,000,000
OE� RETENTION$ $
WORKERSCOMPENSATION STATUTE �RH
ANOEMPLOYERS'LIABILITY ��N
ANYPROPRIETORIPARTNERIEXEGUTNE ❑ N�p ELEACHACCIDENT $
OFFICER/MEMBER E%CLUDED9
(ManGatorylnNN) EL.DISEASE-EAEMPLOYE S
Ifyes,descnbeuntler
�ESCRIPTIONOFOPERATIONSEeIow EL.DISEASE-POLICYLIMIT $
OESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Atltlitional Remarks Sc�etlule,may be dMatM1etl if TOre space is requireE)
Re:Pertnitling wtthin jurisdiction.
CERTIFICATE HOLDER CANCELLATION
Town of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
93 Washington 5[. THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZEO REPRESENTATIVE
of Marsh Risk 8lnsunnee Services
Stehn SzWc . c — .
' OO 1988-2074 ACORD CORPORATION. All rights reserved. �
ACORD 25(2014I07) The ACORD name and logo are registered marks of ACORD
� � OATE�MMIDDNYVY) I
A`�� CERTIFICATE OF LIABILITY INSURANCE tvioizoie �i
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS �
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES �
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATON IS WAIVED,subject to
the terms and conditions of the policy,certain policles may require an endorsement. A statement on this ceRificate does not confer rights to the
certlficate holder in lieu of such endorsement s.
VRODUCER CONTACT
NAME:
Arthur J. Gallagher&Co. Insurance Brokers of CA. PHONE .415-546-9300 F"X .415-536-8499
1255 Battery Street#450 E-MAIL
San Francisco CA 94111
INSURER 5 AFFORDING COVERAGE NAIC k
iNsuaean:Zurich American Insurance Com an 16535
INSURED SUNRINC-01 INSURER B:
Sunrun Installation Services Inc. iNsuaeac:
775 Fiero Lane, Suite 200
San Luis Obispo, CA 93401 INSURERD:
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: 1110908287 REVISION NUMBER:
THIS IS TO CERTIFV THAT 7HE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTNI7HSTANDING ANY REQUIREMENT, TERM OR CONDI710N OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR rypE OF INSURANCE POLICV EFF POLICV EXP
LTR INSD NND POLICV NUMBER MM/ODIYYri MM/DD/YYVY LIMITS
COMMERqAL GENERAL LIABILITV EACH OCCURRENCE $
CLAIMS-MADE �OCCUR PREMISES Eaoccurtence E
MED EXP(AM one person) E
PERSONALBADVINJURV S
GEN'LAGGREGATELIMITAPPLIESPER: GENERALAGGREGATE $
POLICY�PR�- � LOC PRODUCTS-COMP/OPAGG $
JECT
OTHER' a
AUTOMOBILE LIABILITY Ea auitlent $
ANYAUTO BODILVINJURV(Perperson) $
AUTOS�ED AUTOSULED BODILY INJLIRV(Peraccitlent) $
HIREDAUTOS NON-OWNED D $
AUTOS PeracciEent
$
UMBRELLALIAB OCCUR EACHOCCURRENCE $
EXCESSLIAB CLAIMS-MApE AGGREGATE $
DED RETENTION$ 5
q WORKERSCOMPENSATION WC013696001 0/1/2015 10/1/2016 x PER OTH-
q ANDEMPLOYERS'LIABILITY ��N N/C013696101 10/1/2015 10/1/2016 STATUTE ER
ANVPROPRIETORIPARTNEWEXEGUTNE ❑ N�p E.L.EACHACCIOENT $1,000,000
OFFICER/MEMBER EXCLUOE�?
(ManGatoryinNH) E.L.DISEASE-EAEMPLOVE 81,000,000
Ityes,tlescnbe untler
�ESCRIPTIONOFOPERATIONSbelav E.L.DISEASE-POLICYLIMIT $1,000,000
DESCRIPTION OF OPERATIONS I LOCATION51 VEHICLES (PCORp 101,qtltlitlonal Remarks Schetlule,may Ce attacheE If more space la requiretl)
WC013696001 -$25,000 Deductible;WC013696101 -�FL, HI, MA, NJ, NY, OR,VA,WI only.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN '
Town of Salem ACCORDANCE WITH THE POLICY PROVISIONS.
93 Washington St
Salem MA 01970 AUTHORIZEO REPRESENTATIVE
�,�/���
OO 7988-2014 ACORD CORPORATION. All rights reserved.
ACORD 25(2074I01) The ACORD name and logo are registered marks of ACORD
� ����in�
April 14, 2016 STRU(TURAL ENGINfERS
Sunrun Inc.
133 Technology Dr, Suite 100
Irvine, CA 92618
Subject: Structural Certificalion for Installation of Solar Panels
Jab Number: 1G05418
Client: Diane Tache-222R-026BENY
Address: 26 Jackson St., Salem, MA 01970
Attn.: To Whom It May Concem
A field observation of the condition of the existing framing system was performed by an audit team from Sunrun Inc..
From the field observation of the property,the existing roof strudures was observed as follows:
The existing roof structure consists of:
• Composition Shingle over 1x Decking is supported by 2x8 Rafters @ 16"o.c. at ARRAY 1/ARRAY 2.The rafters are
sloped at approximately 24 degree and have a mauimum projected horizontal span of 14 ft 6 in between load bearing
walls.
Desiqn Criteria:
• Applicable Codes=2009 IBC,ASCE 7-05, and NDS-OS
• Ground Snow Load=40 psf
• Roof Dead Load =8.8 psf ARRAY 1/ARRAY 2
• Basic Wind Speed= 100 mph Exposure Category C
• Solar modules=as indicated in attached drawings
As a result of the completed field observation and design checks:
• ARRAY 1/ARRAY 2 is adequate to suppoR the loading imposed by the installation of solar panels and modules.
Therefore, no strudural upgrades are required.
I cerfify that the capacity of the strudural roof framing that diredly supports the additional gravity loading due to the solar panel
supports and modules had been reviewed and determined to meet or exceed the requirements without structural u rade in
accordance with the 2009 IBC. �P`jH oF�ssq
If you have any questions on the above, do not hesitate to call. o
PAULK 'S'G
Prepared By: o ����� N
PZSE, Inc.-Structural Engineers pbsp�pp
Roseville, CA o '+� �,Q
�`SSlONAL��' .
1 of 1
Sl SO Sierto CdlPge 8oule�roid,Suite 150 • RoseaiNe, U 95661 • 916.961.39G4 P • 916.96i.3965 • erHw.pzseaam
��
STRUCTURALENGINEERS
April 14, 2016
Sunrun Inc.
133 Technology Dr, Suite 100
Irvine, CA 92618
Attn.: To Whom It May Concem
re: Job 16-05418 : Diane Tache- 222R-026BENY
The following calculations are for the structural engineering design of the photovoltaic panels
located at 26 Jackson St., Salem, MA 01970. After review, PZSE, Inc. certifies that the roof
structure has sufficient structural capacity for the applied PV loads.
If you have any questions on the above, do not hesitate to call.
�i�'�"'(N�FMqss9
PAULK �'G
Prepared By: ��R �,
PZSE, Inc. - Structural Engineers � s����� N
No_SOtoo
Roseville, CA � ,��-
0
�`SS/ONAI�G`
1 of 5
9150 5i�enna ColEQge 8ou�ward,Suire 154 • Ruseville,CA 956b1 • 4 i 6.961.3960 P • 416.461.3965 • �eer.pzsexasn
Gravity Loading
Roof Snow Load Caleuletlons�
pg=G�ound Snow Load= 40 psf
C,=ExposureFactor= 0.9 (ASCE7-Table7-2)
C�=ThermalPactor= 1.1 (ASCE7-Table7J)
I=ImpoAance Factor= 1
p=0.7C,C�lpa 28psf (ASCE7-Eq7-7)
wherepgS20psf,Pfmin=lxpa= N/A minsnowload�,�,y���s=�
wherepg>20psf,P�min=20x1= NIA minsnowloadp����,��s=�
Therefore,p=Flal Roof Snow Load= 28 psf
P._�.Pr (ASCE7-Eq 1-2)
Cs=SlopeFactor= 7.000 ARRAYI/ARRAY2
'�,, Pa=Sloped Roof Snow Load= 27.7 psf 'ARRAY 1/ARRAY 2
�--"~..PV Dead Load=9�f(Per Sumun Ine.)'" ..""""�
Roof lWe Load.=_78.66_pef ARRAY 1/ARRAY 2
Nole:Roof Iive load is 2moved in a2a's covered by PV artay.
�Roo}Daad Load ARRAY 71ARRAY 2
CompasiGon Shingle 4.00
ix Decking 2.00
- Zx8 Raflers @ 16°o.c. 1.49
VauRed Ceiling 0.00 (Ceiling Not Vaulted)
Miscellaneous 0.51
Tofal Roof DL ARRAY 71ARRAY 2 8.0 psf ,
DL Adjusted to 24�egree Slope� 8.8 psf
2of5
Wind Calculations
Per ASCE T-05 Components and Cladding
�'—Inpuf Nariabl'`��
Wind Speed 100 mph
Exposure Category C
Roof Shape Gable
Roof Slope � 24 degrees
Mean Roof Height 10 ft
Building Least Width 30 ft
Effective Wind Area 10.8 sf
�__ ,
��Deslgn Wind Preseure Calculations
Wind Pressure P=qh`(G*Cp)
qh=0.00256'Kz"Kzt'Kd'V^2"I (E�6-15)
Kz(Exposure Coeificient)= 0.85 (Table 6-3)
Krt(topographic tactor)= 1 (Fig.6-0)
Kd�nd Directionaliiy Factor)= 0.85 (Table 6�)
V(Design Wind Speed)= 100 mph
ImpoAance Fador= 1 (Table 6-1)
qh= 18.50
Standoif UpIiR C'akulations
Zone 1 Zone 2 Zone 3 Positive
GCp= -0.90 -1.70 -2.60 0.50
Uplift Pressure= -16.63 psf -31.37 psf �8.00 psf 922 psf
Max Rail Span Length= 4.0 ft 4.0 ft 4.0 ft
Longitudinal Length= 2.7 ft 2.7 ft 2.7 ft
Attachment Tributary Area= 10.8 sf 10.8 sf 10.8 sf
FootingUplift= -7791b •3371b -5761b
Sfandoff UpIHt Check
Maximum Design Uplift= -516 Ib
Standoff Uplift Capacity = 700 Ib
700 Ib capacity>516 Ib demand Therefore,OK
Fastener Capaeiqr Cheek
Fastener= 1 -5116"dia Lag
Number of Fasteners= 1
Minimum Threaded Embedment Depth= 2.5
Pullout Capacity Per Inch= 205 Ib
Fastener Capacily= 820 Ib
820 Ib capacity>516 Ib demand Therefore,OK
3of5
_ -- — — —_ _--- i
Framing Check
ARRAY PASS
11ARRAY 2
w=53 plf
Dead Load 8.8 psf
PV Load 3.0 psf
Snow Load 27.7 psf � 2x8 Rafters @ 76°o.c.
� Member Span=14'-6" '
Governing Load Comb. DL+SL Note:Attachments shall be Staggered.
Total Load 39.5 psf
MemtierPropertles
Member Size S(in"3) I(in"4) Lumber Sp/Gr Member Spacing
2x8 13.14 47.63 SPF#2 @ 16"o.c.
Check Bending Sfress
Fb(psi)= Fb x Cd x Cf x Cr (NDS Table 4.3.1)
875 x 1.15 x 1.2 x 1.15
Allowed Bending Stress=1388.6 psi
Maximum Moment = (wL"2)/8
= 1364.85 ft#
= 16616.2 in#
Actual Bending Stress=(Maximum Moment)/S
=1264.7 psi
Allowed>Actual—97.7%Stressed — Therefore,OK
Check Deflection
Allowed Deflection(Total Load) = U120 (E=1400000 psi Per NDS)
= 1.45 in
Deflection Criteria Based on = Simple Span
Actual Defleclion(Total Load) _ (5•w*LM)/(384•E•I)
= 0.606 in
= L/288 < L/120 Therefore OK
Allowed Deflecfion(Live Load) = U180
0.966 in
Actuat Deflection(Live Load) _ (5'w'L^4)/(384•E'I)
0.552 in
L1316 < L/180 Therefore OK
Check Shear
Member Area= 10.9 in"2 Fv(psi)= 135 psi (NDS Table 4A)
Allowed Shear = Fv`A = 1468 Ib Max Shear(�=w*L/2 = 382 Ib
Allowed>Actual—26.1%Stressed — Therefore,OK
4of5
_- �
Lateral
2009 IBC CH34
F�cisting Welght of Effeeted 8uilding
Level Area Wei ht s Wei ht Ib
Roof 1350 sf 8.8 psf 118801b
Ceiling 1350 si 6.0 psf 81001b
Vinyi Siding 150 ft 2.0 psf 3000 Ib (10'Wall Height)
Int.Walls 150 ft 6.4 sf 9600 Ib
t Existing Weight of Effected Building 32580 Ib
Propoaed Weight of PV System
Weight of PV System(Per Sunrun Inc.) 3.0 psf
Approx.Area ot Proposed PV System 590 sf
Approximate ToWI Weight of PV System 7770 Ib
1096 Comparison
10qo of F�cisting Building Weight(Allowed) 32581b
Approximate Weight of PV System(Actual) 17701b
Percent Increase 5.4°h
3258 Ib>17T0 Ib,Therefore OK
5of5
� _
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
• SYSTEM SIZE: 10600W DC, 9600W AC . ALL WORK SHALL COMPLY WITH 2O14 NEC,2009 IBC, MUNICIPAL CODE,AND SE SERVICE ENTRANCE SOLAR MODULES' � PV-1.0 COVER SHEET
• MODULES: (40) CANADIAN SOLAR: CS6P-265P ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL PV-2.0 SITE PLAN
• INVERTER(S�: • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O14 NEC.
(40) ENPHASE ENERGY: M250-60-2LL-S2X . ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O14 NEC. Mp MAIN PANEL PV-3.0 LAYOUT
. RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. . pHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL
SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL STANDOFFS& PV-5.0 SIGNAGE
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012 LC PV LOAD CENTER � CHIMNEY
IFC 605.112.
• ARRAY DC CONDUCTORS ARE SIZED FOR DER.4TED CURRENT.
• 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER � ATTIC VENT
• 14.42 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&690.8 (b)).
� FLUSH ATTIC VENT
PM DEDICATED PV METER
o PVC PIPE VENT �ytH OFAqq�9�
INVERTER(S)WITH PAUL K.
INV INTEGRATED DC � METAL PIPE VENT ZACHER
DISCONNECT AND AFCI � T-VENT $ STRUCTURAL y
No. 50100
(. O AC DISCONNECT(S) � � 06����.
SATELLITE DISH �iSS��NAL�v
DC DC DISCONNECT(S) FIRE SETBACKS
� � For Structural Only
�B COMBINER BOX � HARDSCAPE
o '
� � INTERIOR EQUIPMENT —PL— PROPERTY LINE s u n ru n
L J SHOWN AS DASHED SCALE: NTS
A AMPERE -
AC ALTERNATING CURRENT
AFCI ARC FAULT CIRCUIT INTERRUPTER #180120
AZIM AZIMUTH
VICINITY MAP ^ COMP COMPOSITION
200 RESEARCH OR,WILMINGTON,MA 01BB]
� u DC DIRECT CURRENT FPXB 55289]0652]
���"� ' �� •;) ��,,.,� `� ��a �"j (E) EXISTING
� � �� ?Bever"I � EXT EXTERIOR CUSTOMERRESIDENCE:
�..r-_ .,. . y f''
iQ "`�w [y ��"-�„�j�� ' FRM FRAMWG DIANETACHE
� �t.,; � INT INTERIOR 26 JACKSON ST, SALEM, MA,
'y� \'�ri�J � '�.' � ' LBW LOAD BEARING WALL 01970
A{ ♦_ �- l � �PSt� . 7A P!� .� � MAG MAGNETIC
���� , S ' �.� � QQ f MSP MAIN SERVICE PANEL
TEL(978)7402921 APN#:25_0414�
�r�� ,� 7�Y. ' (N) NEW PROJECT NUMBER:
aIj $� : � NTS NOT TO SCALE
� � � / 222R-026BENY
� f * ,� {� OC ON CENTER
PRE-FAB PRE-FABRICATED
�,�,y '``- ' ----� ' �'' 1�� ,,, DESIGNER:
��1'--�"�� I� , /� PSF POUNDS PER SQUARE FOOT
b� � _ �' *� PV PHOTOVOLTAIC NICOLE THOMPSONO
`� rS� � t - � `� �,!�rt'� . TL TRANSFORMERLESS DRAFTER:
Reabody ,�^„= 114 � i� � / '' TYP TYPICAL DIMENSION I
��',�,,,�,�, -���� ,:. ,1 V VOLTS
;+ o , ,._ _� �, L2�Salem.�'tch . � w wnns -
� - - Q511�R�lon� `��>. + �� � SHEET
REV NAME DATE COMMENTS
�.�a � ,��c„ alem�� COVER SHEET
4 ie f�" A
�' i� LG JaCICSO�i S� REV:A1 aizoizois
� .� � �
7 �` �// �+�� �ti PAGE PV-� .O
� �. ,,t �� , � �:
r .•�,..
�
SITE PLAN -SCALE=3/32"=1'-0" PITCH ��M ��M P�SQRTA
� �ACKg� ' AF2-01 24° 277° 291° 346.6
N ST AR-02 24° 97° 111° 346.6
a PL
_
a ' d P(
a .
da '
a ' ..
a
n
a d ' .
a
a '
a . . b
� .
a
�MP a ��N OF��9
� ' PAUI K. �
AC AC � � ° a ZACHER
LC SM �O SE � STRUCTURAL y
No. 50100
a: d. ov/ao/�g
� � o�ss/ONAL��'\
a .
(E) GATE � (E) GATE
0
a
(N)ARRAY AR-01 (E) RESIDENCE
a sunrun
(N)ARRAY AR-02 #180120
n
200 RESEARCH OR,W1lM W GTON,MA O18B1
PHONE888.85]652]
FAX B0552B.9)01
a
0
CUSTOMER RESIDENCE:
DIANE TACHE
26 JACKSON ST, SALEM, MA,
01970
a
TEL.(978)740-2921 APN#:25_0414
PROJECT NUMBER:
a 222R-026BENY
DESIGNER:
NICOLE THOMPSONO
(E) POOL DRAFTER:
a� ` DIMENSION I
` P� � SHEET
SITE PLAN
REV:A1 4/20/2016
PAGE PV-Z.O
ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA
EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES:
° CANADIAN SOLAR: CS6P-265P
AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 8 15'-6" 16" N/A 4'-0" 1'- 10" MODULE DIMS:
64.5"x 38.7"x 1.57"
MODULE CLAMPS:
AR-02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 8 15'-6" 16" N/A 4'-0" 1'- 10" Portrait: 13.39"- 16.14"
Landscape: 7.87"-9.84"
MAX DISTRIBUTED LOAD: 3 PSF
D1 -AR-01 -SCALE: 3/76"= 7'-0" SNOW LOAD:40 PSF
PITCH:24° 11" — 32'_7" — �� WIND SPEED:
AZIM: Z��� 100 MPH 3-SEC GUST.
LAG SCREWS:
�— 5/16"x4.0": 2.5" MIN EMBEDMENT
� 2�_4�� PENETRATION SPACING:
� STAGGERED
— $ — 4'll'P� —O — — �
�,SH OFh���
— $ — —O —O — —
10'-9" PAUL K.
ZACHER �
O_ _ _ O_ O_ _ _ � STRUCTURAL y
No.50100
06/30/2Lp Q.
� r
- C� — — O— O— — — �SS�aNAL�'
3'-I 1" p
! sunrun
D2 -AR-02-SCALE: 3/16" = 7'-0"
PITCH: 24°
AZIM:97° —3�_T�— 29�_4,� —5�_z��—
#180120
�� I ' 200 RESEARCH DR,IMIMINGTON,MA01B81
�
��-8�� PHONE 888 85].852]
FAXB0552B.9]O1
p �9— �9— — — 4'TYP �— CUSTOMER RESIDENCE:
DIANE TACHE
26 JACKSON ST, SALEM, MA,
.e_ .g._ — — — .g— .e_ 01970
���-9�� TEL(978)140-2921 APN#:25 0474
— — O— C�- — — C�- 6- PROJECT NUMBER:
222R-0268ENY
35'-10"
— — �— o-- — — o-- DESIGNER:
NICOLE THOMPSONO
IDRAFTER:
4�_���
DIMENSION I
SHEET
� LAYOUT
REV:A1 4/20/2016
PAGE PV-3.0
120/240 VAC � .. ,
SINGLE
PHASE
SERVICE •MAX 16 MICRO-INVERTERS PER BRANCH CIRCUIT
•MULTIPLE BRANCH CIRCUITS W�PARALLEL
O METER#: •ENPHASE MULTI-PIN CONNECTORS--1ST AC CONNECTOR AT
M NATIONAL GRID 35587616 EACH BRANCH CIRCUIT IS A SUITABLE DISCONNECTING MEANS.
(N)200A LOAD CENTER .DO NOT DISCONNECT/CONNECT UNDER LOAD
UTILITY
GRID SUPPLV SIDE TAP CANADIAN SOLAR: CS6P-265P
IN SEPARATE J-BOX + ,fff + filf ENPHASE ENERGY: +��f MODULES
4 m �� M250-60-2LL-S2X �
�\ (40)CANADIAN SOLAR:
CS6P-265P AND
~ ~ MICRO-INVERTER PAIRS _ (�� gRqNCH OF
�I EXISTING 100A B�DE NPE (N)LOCKABLE � � : : : --- (11)MICRO-INVERTERS
MAIN BREAKER FUSED BLADE TYPE (N)SUN RUN (1)BRANCH OF
AC DISCONNECT METER �\ JUNCTION BOX .i'� ✓` `�' (9)MICRO-INVERTERS
1 AC DISCONNECT � � OR EQUIVALENT
�� 3 3 3 2 � (10BM CRO-IONVERTERS
� EXISTING �� � �
�� 100A °��" °��` OM (1) BRANCH OF
�� MAIN 60A FUSES � (10)MICRO-INVERTERS
FACILITY � " pqNEL
LOADS Fncwir SQUARE D SQUARE D 250V METER
r+ou�o D222NRB DU222R6 SOCKET 20A BREAKER(A)
3R,60A 3R,60A,2P 125A CONTINUOUS 20A BREAKER(B)
120/240VAC 120/240VAC & 20A BREAKER(C)
240V METER 20A BREAKER(D)
� 200A, FORM 2S
NOTES TO INSTALLER:
CONDUIT SCHEDULE 1. INSTALL NEW 200 AMP LOAD CENTER AND 20A BREAKERS FOR EACH
# CONDUIT CONDUCTOR NEUTRAL GROUND BRANCH CIRCUIT. S u n r u n
2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN
1 NONE �2� �2 AWG ENGAGE CABLE (1) 12 AWG ENGAGE CABLE ��� 12 AWG ENGAGE CABLE BREAKER IN SEPARATE ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED.
PER BRANCH CIRCUIT PER BRANCH CIRCUIT
2 3/4" EMT OR EQUIV. (8) 10 AWG THHNlTHWN-2 (4) 10 AWG THHNlfHN7N-2 (1)8 AWG THHNlTHWN-2
#180120
3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 aHONEBB8R5].6 2��INGTON,MA�1B8)
FA%805.528.8]Of
4 3/4" EMT OR EQUIV. (2)6 AWG THHNIfHWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
CUSTOMER RESIDENCE:
DIANE TACHE
26 JACKSON ST, SALEM, MA,
01970
TEL(978)740.2921 APN#:25_0414
PROJECT NUMBER:
222R-026BENY
DESIGNER:
NICOLE THOMPSONO
MODULE CHARACTERISTICS —
DRAFTER:
CANADIAN SOLAR: 265 W DIMENSION I
CS6P-265P
OPEN CIRCUIT VOLTAGE 37.7 V SHEET
MAXPOWERVOLTAGE so.sv ELECTRICAL
SHORT CIRCUIT CURRENT 9.23 A REV:A1 4/20/2016
PAGE PV-4.0
• ' ' • • • . • �BEL LOCATION: � . —.. ._. ..... • • -
�°>�°B, A WARNING l
• • • PER CODE:NEC690.13.G.3 8 NEC � � � O � O �
LABEL LOCATION:
690.13.G.4 ���y (AC)(POI)
� PER CODE:NEC690.13.B THIS EQUIPMENT FED BY MULTIPLE SOURCE pER CODE:705.72(D)(2)
TOTAL RATNG OF OVER CURRENT
'' , . � ,�� � . DEVICES,E%CLUDING MAIN SUPPLV
OVERCURRENT DEVICE SHALL NOT EXCEED
• • • � ' AMPACITYOFBUSBAR
• � ' ` ' � PER CODE:NEC690.56(C)
� � � � � � LABEL LOCATION:
� • � � • (UNDER ROOFING MATERIAL)
'... . . .� - . .•. . . . . - . . . . PERCODE:NEC690.13.G.1 r. . . -- ---- —
A WARNING
LABEL LOCA710N: �
� • � � � . �nee��ocnrioN: '' �I � If II „ ' ,��',1 ELECTRIC SHOCK HAZARD �oc��iniv�
(oC)(IN� :w 4 _ LABEL LOCATION: 7HE DC CONDUCTORS OF THIS PER CODE:NEC 690.35(F)TO BE USED
PER CODE:NEC690.13.8 � � ' � � ON POWERONE INVERTER WHEN INVERTER IS UNGROUNDED
� � I�u i PER CODE:NEC 690.15 AND NEC 690.13(B) UNGROUNDED'AND MAV BE ENERGIZED
CAIJiK)N:SOLAR ELECTRIC
� � . • . � LABEL LOCATION: SY$TEM CONNECTED r A WARN I N G �
(AC)(POI)
, • PER CODE:NEC690.138 ' LABEL LOCATION:
v,se��ocnTioN: TURN OFF PHOTOVOLTAIC pERCODEBNEC110.27(C)
' • • • " ' " • ' ' �nc>�aoq AC DISCONNECT PRIOR TO
PER CODE:NEC690.16.8 WORKING INSIDE PANEL
� • � � � LABEL LOCATION:
LABEL LOCATION: ' � � � � � �
� , , (AC)(POI) • � � PER)CODE:NEC690.33.E2
PER CODE:NEC690.54 A WARN I N G � �
' ' ' ' ELECTRIC SHOCK HAZARD �BEL LOCATION:
A .�u�N LABEL LOCATION: DO NOT TOUCH TERMINALS �AC)(POI) s u n r u n
PER CODE:NEC 690.17.E
(INDIVIDUAL BREAKERS) TERMINALS ON BOTH LINE AND
PHOTOVOLTAICSYSTEM CRCUR I$BACIffED pER CODE:NEC705.12.D.3.4 LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
� • •
• � DC VOLTAGE IS ALWAYS PRESENT
� WHEN SOLAR MODULES ARE
� ' • LABEL LOCA710N: � EXPOSED TO SUNLIGHT #180120
• • • (DC)pN� � Q 0 O ' � LABEL LOCATION:
PER CODE:NEC690.53
' • • (DC)(IN�
PER CODE:IFC.60.11.3 IFC 605.11.1 A 200 RESEARCH DF,NAIMINGTON,MA 0188]
NEC690.i5,NEC690.13(B)&NEC � ���i��R��R�Q� FAX8055289]Ofi52]
690.14C2. rr �� �.��
INVERTER OUTPUT CONNECTION �BE��ocnrioN: CUSTOMER RESIDENCE:
9 0 O P RI,CODE:NEC 705.12.D2 DIANE TACHE
DO NOT RELOCATE THIS
- OVERCURRENT DEVICE 26 JACKSON ST, SALEM, MA,
01970
u �,�.,
TEL.(978)740-2921 APN#:25_0414
� 0 O O � � �� LAgELLOCATION:
EGEND �� (P.C) PERCODE:690.138 A WARNIN�G '� PROJECTNUMBER:
222R-026BENY
C):AC Disconnect LABEL LOCATION:
):Conduit ELECTRIC SHOCK HAZARD �qC)(POI)
B)Combiner Box DO NOT TOUCH TERMINALS pER CODE:NEC 690.17.E DESIGNER:
)Distnbution Panel � TERMINALS ON BOTH LINE AND � NICOLE THOMPSONO
C):DC Disconnec[ � LOAD SIDES MAY BE ENERGIZED • —
C):Interior Run Conduit ,�.,.,1 o IN THE OPEN POSITION DRAFTER:
N�:Imerter with integrated DC diswnned �
C):�oad Center DIMENSION I
):Utiliry Meter � -
Oq:Point of intercannedion SHEET
SIGNAGE
REV: A1 4/20/2016
PAGE PV-5.0