Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
23 HORTON ST - BUILDING INSPECTION (2)
The Commonwealth of Massachusetts �y�y Board of Building Regulations and Standards CITY OF �y11w Massachusetts State Building Code,780 CMR SALEM Revised A4mr 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling "Phis Section For Official Use-Only Building Permit Number: Date ApUlledml- 46-11*^ dY Building Official(Print Name) Signature Dat SECTION 1:SITE INFORMATION 1.1 PM Address:ss_ ®^ 1.2 Assessors Map& Parcel Numbers ].to Is this an accepted street?yes X 110 Map Number Parcel Number rn 1.3 Zoning Information: 1.4 Property Dimensions: r Zoning Dktrict Proposed Use Lot Area(sq fl) Frontage(R) { 1.5 Building Setbacks(ft) 9 r Front Yard Side Yards Rear Yard PO Required Provided Required Provided Required Provided G0 CM rM 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone?Check ifyes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Record: Pete L'Italien Salem t.Ak Name(Print) City,State,ZIP 23 Horton St. 978-760-1573 Peter.litalien@gmaiI.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction Existing Building❑ 1 Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Description of Proposed Work': S _Rh—o+Dy n Wa-IG Sol0.r Sy,S. S SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Labor and Materials Official Use Only I.Building $"4CO I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $a - ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x trultiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ ❑Paid in Full ❑Outstanding Balance Due: i SECTION 5: CONSTRUCTION SERVICES 5.11-Construction Supervisor License(CSL) © 2 5 1 28 _ License Number Ex cation a[ Name of CSL Holder �` kcu r,, S ^ List CSL I ype(see below) U No.and Street phl Type Description SQ(.f lkS i KkA a Q� U Unrestricted(Buildings u to 35,000 ca.fi.) _t R Restricted 1&2 Family Dwellin Ciq/Town,S "LIP M Mason ry RC Roofing Covering INS Window and Siding cf SF Solid Fuel Numing Appliances l3 US h DL-2. Q V(VL rp 1 Insulation Tele hone Email address rvl D Demolition 5.2 Registered_ Home Improvement Contractor(HIC) t-nyyt' So1au'D2VeloPeY LLC 1-10�648 4 Cm N. a�o HICRgistranl Name HIC Registration Number E ppi`r`adon Date L a3 a N trmC) w.aSola -C�VtVInA-so Ir. 1orOVot 1$ 35301¢S Emai address (wvtUT 164(OD4 . ,I City/Town,State,ZIP Tele hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes.........'A No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize VI V l✓1i- Sfl IGlr to act on my behalf,in all matters relative to work authorized by this building permit application. pw�-OL t)14-11- 9/15/14 Pnnt Owncrs Name(Electronic Signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information [containedathpion is true and accurate to the best of my knowledge and understanding. 0 Agent's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can he found at www.mass.pov/oc Information on the Construction Supervisor License can be found at www.mass.eov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/atties,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms _ Number of half/baths Type of heating system Number of decks/porches 'Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CERTIFICATE OF LIABILITY INSURANCE D1%11201133°""""' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES 1' BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen s). PRODUCER CONTA MARSH USA INC. NAME 122517TH STREET,SUITE 1300 PHONE FAX DENVER,CO 80202-5534 EMAIL Eat _ a/c Rol. Attn:Denver.certrequest@mandnoom,Fax:212.948.4381 ADDRESS: WSURE $ AFFORDING COVERAGE NAICX 462738-STND-GAWUE-13-14 WIRER A..Evanston Insurance Company 35378 LIK ED Solar,Inc. INSURED INSURER B:National Union Fire Insurance Co of PA 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Provo,UT 84604 U13URER D: INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002368030.06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED-BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IL1RR TYPE OF INSURANCE AOOL SUER POLICY NUMBER MPo CY EFF POMMM DMn3 A GENERAL LIABILITY 13PKGWE00274 1V012013 11/01/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL UABWTY 50,000 PREMISES Ea ouunanre $ CLAIMS-MADE M OCCUR MED EXP(Any one Person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE S 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 2,000,000 X POLICY PR0. LOC E B AURIMOBIL.ELLASLaY 9701087 11M112013 11/012014 OMBIIWDISINGLE LIMIT E 1000000 B X ANY AUTO 9701088 11/01/2013 11/012014 BODILY INJURY(Per Person) S AAUTOS EO SCHEDULED AUTOS BODILY INJURY(Per accident) $ X X NON-0WNED FROPERr DAMAGE HIRED AUTOS AUTOS Peracoderr $ $ A UMBRELLA LIAR X OCCUR 13EFXWE000BB 1110112013 111012014 EACH OCCURRENCE S 10,000,000 X EXCESS LIAO CLAIMS-MADE AGGREGATE $ 10,000,000 DED RETENTION$ g C WORKERS COMPENSATION 029342334; 029342335 W012013 11/012014 X WCSTATu- OTM- AND EMPLOYERS'LINBRITYLIM C ANY PROPRIETOR/PARTNERIEXECUrIVE YIN -029342336; 029342337 111012013 111012014 E.L.EACH ACCIDENT $ 1,000,000 C, (Mandatory aOFFICERMEn NH) �N NIA (MandaMME BER 029342338 11/012013 W012014 E.L.DISEASE-EA EMPLOYE $ 1,000,000 If yes,desuibe wrier DESCRIPTION OF OPERATIONS below, E.L.DISEASE-PODGY UNIT 1$ 1,000,000 A Errors&Omissions& 13PKGW00029 11/012013 11/012014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ABaeh ACORD IM,Addidomi Remake Schedule,R mare apace is mwoedl The Certificate Holder and others as defined in the written agreement are included as additional insured when:required by written contract with respect to General Liability.This insurance is primary and non. ntributory over any ensfing insurance and limited to liability arising out of the operations of the named insured and where required by written contract Waiver of subrogation is applicable where required by written contract with respect to General Lability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.ParsloeS,(l7lr. IaWlsG ®1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents —l Office of Investigations (' 1 Congress Street,Suite 100 125P`4) - Boston, MA 02114-2017 wwwmass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organizationnndividuaq: Vivint Solar Developer, LLC Address: 4931 North 300 West City/Slate.'Zi :_Provo UT84604 _ Phone#: 801-704-9389 Are you an employer? Check the appropriate box: Type of project(required): 1. X❑ 1 am a employer with 10 4. ❑ I am a general contractor and[ employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These.sub-contractors have g, ❑ Demolition workingfor me in an capacity. emplovecs and have workers' y p ry 9. Buildingaddition [No workers' comp. insurance comp. insurance.! ❑ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box 41 must also fill out the section below showing their workers'compensation policy infortnation. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. i Insurance Company Name:__ _New Hampshire Insurance Company Policy#or Self-ins. Lic. 4:- 029342228 Expiration Date: 11/01/14 Job Site Address:_, �yY __ City/State/Zip:_Jt YY , Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under pains i id penahie of perjury t i the information provided above is true and correct Signatut�e:.--?1704-9389 -- — _ Datc: Phone'!: -� t Official use only. Do not write in this area,to be completed by city or town official. N City or Town: `Permit/License Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other_, Contact Person: Phone#: viaas.c vt % v � c �— uutua tAilau aatu L �auulc� �c I WE � rutaL1V11 ') 10 Park Plaza - Suite 5170 I Boston, Massachusetts 02116 Dome Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLO. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. SCA 1 is 20M-05111 FAddress ❑ Renewal Employment Lj Lost Card Massachusetts -Department of Public Safety �✓ Board of Building Regulations and Standards Construction Supenisor License:CS-W254 DAMES R SHER'41AN - 6 Fox Hollow Drive SAUGUS MA 01906 r d Expiration 08/28/2016 Commissioner r lJ i v i Y Y 0 solar 4931 North 300 West Structural Group Provo,UT84604 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scatt.wyssling@vivintsolar.com September 16,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services L'Italien Residence 23 Horton Street, Salem MA AR#3231327 5.0 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of assumed 2 x 6 dimensional lumber at 16" on center. The attic space is finished and photos indicate that there was no access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SE17-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 34 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per(ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivi t. solar Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF=Live Load(around snow load) • 5 PSF= Dead Load solar Panels/mountina hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 Yi', is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 Yi' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64" o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, �tNOF �a )VIP y Scott E. Wysst PE ° so MA License N . 50 9�F FGis7EF� FSStONAA- vivint. solar Al V INTERCONNECTION POINT, LOCKABLE DISCONNECT SWITCH, ANSI METER LOCATION, &UTILITY METER LOCATION o<� �z 50'OF 1"PVC CONDUIT E z az FROM JUNCTION BOX TO ELEC PANEL n'y O ------ -- O .� Q -- -- - —� PV SYSTEM SIZE: 5 kW DC C) s.. I I o E 0 cc .e •C= I I 4-7 � J I I � s � m mo _ a 0 w � z a m JUNCTIONSOXATTACHEDTO 2 K L V ARRAY USING ECO HARDWARE TO J J z m KEEP JUNCTION BOX OFF ROOF I M Q Q 3 N vZ 9n ¢ 0 = = 2 o � - - - --- - --- - - -� SHEET — NAME: (20)Trina Solar TSM-250 PA05.18 MODULES WITH A Lji J Enphase M215-60-21LL-S2x-ZG MICR04NVERTER MOUNTED ON THE BACK OF EACH MODULE a SHEET NUMBER: PV SYSTEM SITE PLAN SCALE: 3/32"= T-0" a 0 oZ7 0008 SO NO m� m O(] uy On Nm 0C o uz Cy oy mu .o i m A tt 3 v N 2 0 N m a< 00 'er CC mC my Np n D < r C m -< w Cn m II � o O O -n 0 -u m r z D z c i D i INSTALLER:VIVINT SOLAR t gm ;m INSTALLER UMBER:1.077.404.4129 `{�- +.^�{ L Italien Residence PV 2.0 m y ROOF ^y MA LICENSE:MAHIC 170848 V ivO nt� V 23 Horton St V G p PLAN DRAWN BY:CRS AR 3231327 Last MotlifieQ 9IBI2014 UTILITY ACCOUNT NUMBER 1327E93033 CLAMP MOUNTI SEALING m NG PV3.0 DETAIL WASHER LOWER SUPPORT L.L cam=LL z �Ez C�.00 PV MODULES, TYP. MOUNT OF COMP SHINGLE ROOF, FLASHING @ F PARALLEL TO ROOF PLANE / 2 1/2" MIN J 5/15"0 x 4 1/2" >w MINIMUM STAINLESS PV ARRAY TYP. ELEVATION STEEL LAG SCREW NOT TO SCALE TORQUE=1322 ft-Ibs ` CLAMP ATTACHMENT J) NOT TO SCALE •o W CLAMP+ 8 ATTACHMENT CANTELEVER LA OR LESS COUPLING L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE a MODULE CLAMP SPACING. y m n PERMITTED COUPLING g m < m CLAMP+ CLAMP - CLAMP ATTACHMENT VCING z m = COUPLING PHOTOVOLTAIC MODULE z m U z w .. a m > w w z m w z z MIN f O mt77 7 M SHEET NAME: L=PORTRAIT N U) CLAMP SPACING Zo Q o F ECO O L= COMPATIBLE PV SYSTEM MOUNTING DETAIL SHEET LANDSCAPE MODULE NUMBER: CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE d Inverter Ratings(Guide Section 4) Invader Makemledel Enpbaae Mel s.fi6-2u-s2xa%24V�'. Conduit and Conductor Schedule MODULE DETAIL Max DC Volt Red, Tag Derseaption wi2camad xofLondaread LoMunType ConduitS¢e Max Power®4o°c I Fnsi enge9a doae-THWN-2 12 Awc 4 card N. Free ss Nominal AC Voltage t Bara CopperGmund(EGL/GECI fiPWG t N/q-Free Pir NIP-Free Pir VTdna Solar TSM-250 PA05.18 Max AC Cadent de SOLAR MODULE Max CCPO Retina 2 THwN.2 to A. a ep1' Crb Max Number of Panehatirwit 9AWG PVC V4' 2 THWN1Gmund 1 3 LAWN-2 6AWG 3 PVC p'1' mp NOTES FOR INVERTER CIRCUITS(Guide Sadion8and 91: a Hi Gmvnd BPWG t wC p-1' Nromm 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS — (1)co� Promise M215-60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? PV Module Ratings(�STC(Guide Section 5) N o Z MICRO- YES. NO XNA Model MakeMtodel Trine Solar TSM-250 PA05.16 x INVERTER AT n w r MaxPower-PoinlCunenl(Imp) 8,2] Am s Z EACH MODULE ATTACHED2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Point Vbta9e(Vmp) 30.3 Volts �ra.0 WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? 0 Open-Circuit Voltage(Von) 3].6 Volts _ YES NO XNA Shod ircuil Current gut 6.65 Amps 4� Q 3.)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Sence Fuse(01 15 Amps co BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power a15T Frad) 250 Wans MICROINVERTER CONNECTION RATING AT DISCONNECT. Voltage 1p00(IEcy500(UL) J j TO ENGAGE TRUNK CABLE 4)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Maximum system v Vox Temperature Voltage ^ TO INVERTER OCPO AMPERE RATING(So.Guide Setlipn 9). V 5.)TOTAL OF 2 INVERTER OCPDi ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide section 6 and 6 and Appendix Op PV CIRCUIT.ODES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN It Lowest expected ambient temperature based on ASHRAE minimum mean extreme �•� NEC 690.64(B)(2)(a)? XYES NO any bulb temperature for ASHRAE localion most similar to installation location: -19°C N6 BARE CU GROUND �14.1 (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb •. - temperature for ASHRAE location most similar to Installation location: 39°C Sign for inverter Odi and AC Disconnect 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the C United States(Palm Springs,CA is 44A°C).For less than 9 cumenl-carrying conductors Solar PV System AC Point of Connection in roof-mounted sunlit conduit at least OE"above and and using the outdoor design AC output Current 1 16.000000 Amps temperature of 47-C or less(all of United States). 'Y Nominal AC Voltage 2401 Value a.)12 Ali 90°C conductors are generally acceptabe for modules with lsc of 7.69 Amps or less when p bteded by a 12-Amp or smaller fuse. THIS PANEL FED BY MULTIPLE SOURCES ry (UTILITY AND SOLAR) a)10 AWG,90°C conductors are generally acceptable for modules with lsc of 9.6 Amps m or less when prodentedb a le-Arrip or smaller fuse. •0 m NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY to ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR 7s ol PV CIRCUIT 1: 10 MODULES/PARALLEL ENVOY BOX ? m gm � no ,D • • • p4ARALLEL ' (RWPitt oaa MURRAY POINT OF DELIVERY > wCOMBINER AND INTERCONNECTION www 1s \yOPO PANEL 125A/240V SIEMENS ¢ ¢ 0 3\G G LW004NR 60AI240V y y Q PO ko 20 OR EQUIVALENT UNFUSEDNEMA3 M i zPV CIRCUIT 2: 10 MODULES/ O\j,\ra AFL 1 SREC/ANSI LNF222R OR SHEET j 0 METER EQUIVALENT NAME: i \O EXISTING a 10 • • is \'P j11A LOADCENTER ZE,D M ot)z o ✓` • • • f f \ JA SHEET _ NUMBER: ` \\ MILBANK VISIBLE/LOCKABLJE JUNCTION BOX z \\ 3 1ODA OR 3 'KNIFE'A/C EQUIVALENT NEC 2014 Cam liant WITH IRREVERSIBLE E 1 0 \ BLG E 1.0 DISCONNECT p GROUND SPLICE \ E 1.0 U5934-XL- LS.I k. . Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Michelle L'Italien Project Address: 23 Horton St,Salem MA A.System Description: The array consists of a 5 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(20)250- watt modules and(20)215-watt micro-inverters,mounted on the back of each PV module.The array includes(2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C.Minimum Design Loads: Ground Snow Load: 40 ps-f (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2.Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing _ B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2. For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrium Solar b.Product Name: Eeorail c.Total Weight of PV Modules and mounting hardware: 860 Ibs d.Total number of attachment points: 30 e.Weight per attachment point 28.66 Ibs E Maximum spacing between attachment points: *See attached engineering talcs g.Total surface area of PV array: 352.2 square feet h. Array pounds per square foot: 2.44 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (20)modules,(30)attachments 28.66 pounds vlvint. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 20 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voc-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Ise-rate short circuit current - 8.85 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 20 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 10 modules/inverters (15) amp breaker PV circuit 2 - 10 modules/inverters (15)amp breaker 2011 NEC Article 705.60(B) vivint. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 9 amps Continuous current adjustment factor 125% 2011 NEC Amdc 705.60(B) PV circuit continuous current rating 11.25 amps 2.Overcurrent protection device rating PV circuit continuous current rating 11.25 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amo AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Amde 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Arude 705.60(B) Adjusted PV circuit continuous current 15.8 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 800X� 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 19.8 amps Total derated ampacity for PV circuit 19.8 amps Conductors(tag2 on 1-line)must be rated for a minimum of 19.8 amps THWN-2(90°C)#14AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Aalcle 705.60(B) 4.Voltage drop(keep below 3%total) 2 Darts: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.48% The largest number of micro-inverters in a row in the entire array is 10 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.48%. 2.AC conductor voltage drop: =I x R x D (-240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#14AWG copper)x(Total wire run) =(Circuit 1 nominal current is 9 amps)x(0.0031962)x(100)-(240 volts)x(100) 1.19% Total system voltage drop: 1.67% Nivint. Solar �p EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 11082 Street Address Line 1: 23 Horton St Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-250 PA05.18 Module Quantity: 20 Array Size(DC wafts): 5000.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M250 Project Design Variables Module Weight: 41.0 Ibs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: If Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load - Lateral: 300 Ibf EcoX Design Load -Downward: 493 Ibf EcoX Design Load -Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load-Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-05): 1 Roof Type: Composition Shingle Average Roof Height: 30.0 ft Least Horizontal Dimension: 30.0 ft Roof Slope: 34.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.66 0.66 0.66 Roof Snow Load 22.2 22.2 22.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -17.1 -20.1 -20.1 psf Net Design Wind Pressure Downforce 1&0 16.0 16.0 psf I, Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -17.1 -20.1 -20.1 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 22.2 22.2 22.2 psf Downslope: Load Combination 3 11.6 11.6 11.6 psf Down: Load Combination 3 17.2 17.2 17.2 psf Down:Load Combination 5 17.9 17.9 17.9 psf Down: Load Combination 6a 25.4 25.4 25.4 psf Up: Load Combination 7 -15.9 -18.9 -18.9 psf Down Max 25.4 25.4 25.4 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 65.2 65.2 65.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.7 21.7 21.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 43.1 43.1 43.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.4 14.4 14.4 in Layout a ko I -.I a a Skirt o Coupling Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Clamp maximum allowable overhang. AN (Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 820 Ibs Weight of Mounting System: 60 Ibs Total System Weight: 880 Ibs Total Array Area: 352 ft2 Distributed Weight: 2.5 psf Number of Attachments: 30 Weight per Attachment Point: 29 Ibs Bill Of Materials Part Name Quantity ESEGOICLASA EcoX Clamp Assembly 30 ESEGO1COASA EcoX Coupling Assembly 20 ESEG01SKKTA EcoX Landscape Skirt Kit 5 ESEG01 SKKTA EcoX Portrait Skirt Kit 0 ESEGOICPKTA EcoX Composition Attachment Kit 30 ESEG01 ELASA EcoX Electrical Assembly 1 I