Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
9 HILLSIDE AVE - BUILDING INSPECTION (3)
D The Commonwealth of Massachusetts INSPECTIONAL RVICES s+\+�Yk IIy Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALEM >: 12. 21 ' Building Permit Application To Construct,Repair,Renovate Or Demolish a ioIy #�? One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Dat pplied: Building Oflicial(Print Name) Signature Date SECTION 1:SITE INFORMATION LI Property Address:: ^ it l+p//) 1.2 Assessors Map&Parcel Numbers 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq R) Frontage(tt) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone?Check ifyes0 Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'ofRecord; Kevin Odonnell Salem, MA. 01970 Name(Print) City,State,ZIP 9 Hillside Ave 978-436-1136 No.and Sweet Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work': } n ai rex>F —,, U S tM SECTION 4: EST[MATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ '1 ❑Standard City/Town Application Fee K ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Su ression Total All Fees:$ 4 ass 6.Total Project Cos[: $ Check No. Check Amount: Cash Amount:_ 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) Nt)—IIS 2-S) (Q JCg S she r(naem—) License Number I Expiration Date Name of CSL Holder l -L C VVMa� _0 ^ Lis[CSL Type(see below) L/ No.and Street (l✓` Type Description v� U Unrestricted(Buildings u to 35,000 cu.it.) R Restricted 1&2 FamilyDwelling CityITowq Stale,ZI M Mason ry RC Roofing Covering WS Window and Siding _ `� `,.. SF Solid Fuel Burning Appliances '155)�Ds�Dw`7 MaS •yU\V 1�}��tUY 1 Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) V\y 1 nt Scxc r \-Io�m S \it)1>n HIC Co or jilC.Re Name HIC Registration Number Expiration Date rpplgy1N�mgis at No.and-Street Email address City/Town,State,ZIP ` Telephone`v' SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........❑ No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize J WXY)t 56Cl1r to act on my behalf,in all matters relative to work authorized by this building permit application. j)' -0'/ " 12/18/14 Print Owner's Name cuonic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print Owner's or Authorized Agent' a(Ele nic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at i v .mass.eov/ocu Information on the Construction Supervisor License can be found at www.mass.eov/dos 2. When substantial work is planned,provide[he information below: Total Floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" rr� t(rty�rvr�r�rr/�1�ti�o w�w.Y.�uc��,�irtiy Office of Consumer Affairs ty�nd Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. sCA 1 0 20M-05111 Address Renewal Employment Lost Card i Massachusetts-Department of Public Safety Board of Building Regulations and Standards Construction Supe-045252544, License: CS ' JAMS R SHERMAN " - 6 Fox Hollow Dri4e SAUGUS MA 01406 � U a Expiration Commissioner 08/28/2016 0 The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations 7 I Congress Street,Suite 100 Boston, VIA 02114-2017 wwW.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/organization/individuaq: Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/StateiZip:Lehi, UT 84043 Phone#:801-377-9111 Are you an employer?Check the appropriate box: general contractor and I Type of project(required): 1.E I am a employer with 10 4. ❑ I am a g employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling shipand have no employees These sub-contractors have 8. ❑Demolition working for me in any capacity employees and have workers' [No workers' comp. insurance comp. insurance.t 9. ❑ Building addition required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL insurance required.] t c. 152, §1(4),and we have no 12.❑Roof repairs employees. [No workers' 13.©Other Solar Installation comp.insurance required.] "Any applicant that checks box HI most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance foe my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic. #:WC 509601300 P 11/l/2015 Expiration Date: 7 Job Site Address: q44 I',I (� 7TV( City/State/Zip: Mob) Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true t and correct. Sian re: /7� `_�� Date I2I?111 'I Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: it 4VJ1 Noah 300 West,Provo,UT 54604 Employer Idcmlification No.: 80.0756439 V�VII'1t. solar"Numa(g77)404.4129 Faz:(ROI1765.575g MassachusettsHlCl.icenseNo 170949 li-Mail: supportavivintsolaccom Yoga /�5 www.viwintsularcunl AR No: t(1 RESIDENTIAL POWER PURCHASE AGREEMENT � This RESIDENTIAL POW17R PURCHASE AGRf;CMEN'1" this"elgreenuent")is entered into by and between VIVINT SOLAR DEVELOPER. LLC,a Delaware limited liability company("IVe.....IA'."Our")and lha undersigned Costumens)C lot',by ).as oflhc Transaction Date sel it blow. Full Name wn,r.act.r,.nr Full Name en.1-1, Customerlsk Po, ,,tins o It, ow, vi �'0�0 �V1el r.......1,O „er, or.�, owe 4 Telephone NO.: _ E-Mail: Property Street Address: I Q 1 Address: City,County,State, I.SI?I2VICE5 A. DESH;N AND INSTALLATION. We will design,instill,service and maintain a solar phom"Ohnic system On Your Popery,Which Will include all solar panels,inverters,Ulc ers.and other components(collectively,the.",Srstcni I,as further descrilled in tln•.Customer Pnekel and the Work Order that We will provide ill hereafter. All material Portions of the Sysien,will 6c instailM by Our emplo)'ed technicians and elatria;tas,ant]not subcontractors. With Your ctaycnuiun. We will 0)design, install and connect the System in material compliance With all applicable lav,s; (i0collpleic all required inspection,:tint(iii)obtain;ill required certifications and permits. In order to design a System that rivets Yourneeds,You agree that We may obtain Your electrical usage history Innn Your eleclne uuhty(theUahpp ))and You shall nwldc Us with Copt Of four Utility bile as We may reasom6ly request. Other than the acovntiin lec described In Sectmn H QV ailll.rlutgn and It'I I the•:SYsiein atyh o�cn t to Yo:c.1 B. ACI'1\S\PION. Ynu ngmc lO pa} Us a one-IIm Wait onion Ice it th a nun ni t I$ S!> W will incrcinned the Syacm vvnh the Unlit}',and cause the System to generate energy measured In kluwau hours ( All/,")((hc 'Eacr,L. ) naLtnslallauon of the System generally takes one day nand is anticipated lO begin and he subsmn,i l 1)complete ben c o two(2)and sis(6)necks hue Uler. C. OWNLRSHIPOFSISTEN1 \Ve sh tlfowmthr�Syst ncas Otr ale pease nail-prolurlvavYou wlllh to no property min tin th Sysl m. D, OPEH\'f IONS AND MAIN'I IN\N'CE.rR^c all of r5feanlnummm the Sv tun(n)T llucsoc cost and espen (it}wgtnd cond'aiun:}ud�(ii i)it, mm m �al compliance with all applicable laws and penis and the Utility s 0CLUi cii i E. INSURANCE. t...r rs.,cmapvi own iasamnec-,lnd property insurance on the Syslemilf For more fit tornaion concern ing Our imumnec.;III([to obiainit copy of Ou r celat hcarc otmsurance.phase visit st t�w.vtvaisnl lCumt71lhmm�C . 2."PERM,PRICE,PAVM ENTS,AND FINANCIAL DISCLOSU KITS W. ENERGY PRICE. For ail Energy produced[is the System.You shall pay Us$0. per kWh((ihe"Energy Price").plus applicable taxes. The Fncrgv Price shall merease-each:year byy twill nmc tcuthsp rcent( .VA), A cu i0 a osamwte of the Svsten output,measured In kilowatt hours, will b ml ,fed to You in file Cum tin r i ncki t. 'flu IN A( RITMI:N f ISl FOR-1[IF Will, OF FNI.R(1'BY US TO YOU AND NOI I OR THE SALT:OF A SOI ,It ENERGY DEVICE. B. FERNI. This Agreement slot]he efcdiwv as.1,the Tnusoction Dice and continue until the°RtC helb—GO's)onniecrsnry-o]'the In-Service ITae(the i "Tern"). The aYn-Serviie Dare"shall be the first day oiler all if the I'Otlowing have been achieved: (i)the Svsten,has been mstallcd and is curable Of generating Energy',(if)all permits necessary tin operate the System have been o fained,(iii)Zile System has been Interconnected wnh the Utility,anti(iv)all ,aspect ons and cert dicales required Under appfucable law or by the Ul it l t)have been cumplcled Or received. C. I \1 N1 EN'l S. Beymorayy wnh ih 'frsr.month Inic.wing the In Sen ice Dare iid-thioughmn the T erm.-We-tvdl scru Pest an invoice rei in�the (eatery . filrPtTngy-pronc�tat the System in the itevtous-monihTYou shnll•m;tke monddy.payments to Us hy-amomttiepavinem-deduction-from our" desigmtivd chucking account it credo nod. II is four responsibility to ensure that there are adequate Nnds or adequate cram limit. Then is no fnunciU( ...,� charyc associated with this Agreement. For all ppaymen is ,,are than ten(It)dt)s past(Inc.\Ve may Onpose n late charge equal I"I"wcnly-Five Dollars($25) 'cod Interest at cot annual one of ten perecni(I OYu,plus applicable lanes. if You continue k)fail to make any payment within ten(10)days oiler We give N'o t written notice,then We may exercise all natualics available to Us par a cot to Section 1 nth). D. RENEWAL. Al the end of the lean You may elect to(i)Gmunue With this A rccmcnton cyeaelo year basis (ni) nterinto a uvw:Ameement With Us and caned this AKevmlvit:(uI)purcha C ih System at the'and of the Perm.ant cancel this Agrotanent'(the'Pureha2i-Option ) Or 6v)-eaned this.: Agreement and hate c System-rcniovcd at no cost to You? You Will need to notify Us fit Writing canccmm66;Your election shcn(60)days prior to the end Of the lena. II'a ou let die purchase Option, thePurchase Opruar Price' will he the then current ;lit market value of the S)slen based on an independent appmser s valuation of sumlarly sized photovoltaic sys0.nu m You,k�ographc wraul. the Upraise,',valuation ruin he provided to You In writing and WIII be binding. II'We receive Your pa)'nient ol'the Purchase Option Crice.costs a the anppraisnl,applicable nixes,and all other amounts then owing and unpaid hereunder,We Will transfer ownership of the Sys cut lit)'oil at the end of tht,Fcrnt On tin"As Is,Where Is"basis. It You elect it,have the Systrnt removed,We will remove ilhe S))arm from Your 11 ice)) within hove>'(90)dayys alter the cod of the Icon. IF YOU DO NOT NOTIFY US OF 1 OUR ELF.CI'ION TO CANCEIL 11Y. SE:N'I1ING A \1VI io'.N NO I'IC'E l'O US, THEN *1 HIS AGREE:NIEN'I WILL AUION1ATICALL I' RENEW ON A YEAR-FO-YEAR BASIS UN I'll,YOU NOTIFY US IN'WRITING OF YOUR ELECTION TO CANCEL AT LEAS"F SIX I'll(60) DAYS PRIOR'1'O'I'HH END OF"f HE RENEWAL TERM. E. CRE DI'I'CHECK. In connection With the execution(it this Agrecniunt;cod at any time dining the Penn,You herehv authorize Us to 0)obtain Your credit rating and rcnurl front credit repining agencies;(ii)it)report Your payment performance ender(his Agreall TI io credit reporting agencies:and (ill)disclose this and other infunmutum It,Our affiliate and actual Or paospedrvc lenders,throrcing pmmUcs,investors insurers,and acquirers. WE MAY FIAVI PRflSC:RRENGD_Y:OUR_.CREDIT, PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CIi OOSE TO STOP RECEIVING "PRE SC R E EENFD'•OFFERS OF CREDIT FROM US AND OTFIER COMPANIES BY CALLING TOLL-FREE (RRR) 567-8688. SEE PRESCREEN & OPT-OIJT NOTICE(SECTION 29) BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. I J.LIMITED WARRANT-Y A. rLINII`I ED-IN:S'I'ALLATION\A\RW\,N]1. We provide it Workmanship waa'rmhv that the Syswn shall he Roe Bann ntaeriat deF ca in desi�gn and l e)codmi t It i)ider norni.d Operating conditions both,awn We Nutlet ttnrnvm that rc,cdl,p put nauoiis Wv insellahall h-walerf as of theclaeoll host llauon, Wic do not pr ride a oy vtavamly w You with spe'l m any ...lwnenH.1-Ih :4yaem�Anv^manuluUuru s worm ny,in m;Minion to iii In het l of efts IimiicJ installationn umnty. this vtarmnty does oat uw er pn h4nrs resulunk. Iomn ceps core Ii haumiul materials and chcnucals )ire Iloud, rirthquak..o.other acts of gitJ,wn I hsm hcrub<n I 'v't m I+y anyone in a,thorize 1 lw Us.oranycolaxrcause 1 .rid Our mmtrol, B. NL\NUFAC I'D It ERS' \\ARRWNfII S. 'fIn S's ill sntal modules wary t mw.inimu menul cturer's,warranty it twenty,(20)years as fidlows: (a)during the first ten(19) trs ul use,the(nodules'electrical output will not degiade by more Ilan ten pacems(10%)Front file oriemallJ mhcd ouIpuf,and (b)Burin,the lirxi Iwenty 211)years ul ua'e.Ihv nnulnles'electrical nuyml will all degrade by nuu'C than nomp..vent ho akdo.from the g&rally ,rated We ouh�ui. is System's inrericrs enrr�'n minimum plan iffa 1urcr's wnrruniy of;ten(Ill)years agninsl ddiets ur n,nyrnncm brcakdow'ns. Joining the 1'enu,\Vc l wit enfnrce these warranties to the infest extent possible C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION i, WE MAKE NO OTHER WARRANTY TO ' YOU Oil ANY OTIJER PERSON, WHETHER EXPRESS, IMPLIED OR S'IA'fU'1 OItY. AS TO THE MCRCIiANTABILITY OR FITNESS FOR ANY PURPOSE 017 THE: EQUIPMENT, INSTALLATION, DESIGN. OPERATION. OR MAINTENANCE OF THE I SYS"I-L"M. THE PRODUCTION OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MA"ITER I HEREUNDER, ALI, OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANY BREACH OF ANY I WARRANTY IS LIMITED TO REPAIRING THE SYSTEM OR YOUR PROPERTY TO TIIE EXTENT REQUIRED UNDER THIS AGREEMENT. YOU ACKNOWLEDGI; 'FITAI' WC ARC RELYING ON THIS SECTION 3.C. AS A CONDITION AND MATERIAL INDREMiiNT -1.0 ENTER INTO -IBIS AGREEMENT. THERE ARE NO WARKANTIBS WHICH EXTEND BEYOND 'I-HE DISCRIP'I'ION OP'IIiE FACE HEREOF. 1 4.REMOVAL OF THE SVSTE:M You shall not nuke any Alnrminns(as ddinal In Sc Minn 7 c )to the System_df You Want to make repairs or imprn otalWo sto'Your Property,[flat require aihe.temporury I'cmu d o1.th•$ys'tem ur tharcuuld toter d'e wit i is-p rhirmance pr operation,YOU nuts] ie Us al I•i,i thirty(10)J rys prior written notice (a"Cnsrnnrer-Reyucared Shur4mvu'). You agree that an),repair or imp to to Your Properly shall not matrn;lly alter Your roe where the System is stalled. As coneppe,,ati Ibr Our mnun'nl,slOrage,and rcinstallamon ol'Ihe System Ynu ogre to pay to Us o fey equal to pour Hundred toil Ninety-Nine Pollan(($499)`hcliuc We runlovc the System. You shall he reyuincd hn pay the Shutdown I'oyman nos def ncd in Srduon I51 the System Is nil rcmstalled Within-thirriy(30)days of Wanoni. In the event(Full emergency f econg the System. You shall contact Us name Liicly. 11' V i arc unable to timely respond,You may(at Your own expense)contract with a licensed tint]qualthed solar Installer tin remove the Svstcm;s neces'sar-v li make repairs required by the emergency. You shall he responsible for any damage w the System that results front actions taken by Your contractor. 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quickly and amicably by calling Our customer service department at (877) 404-4129. If Our customer service department is unable to resolve Your concern,You and We agree to resolve any Dispute(as delinal below)thrnuSSth hindin• arbitration or small claims court instead of couns of&ctieral]jurisdiction. 13Y SIGNING BELOW,YOU ACKNOWLEDGE ANI)AGRE- 1-1 A'f(1)YOU ARE HEREBY WAIVING THE RIGHT TO A TRIAL BY JURY;AND(II)YOU MAY BRING CLAIMS AGAINST US ONLY IN YOUR INDIVIDUAL CAPACITY,AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR -REPRESENTATIVE a PROCEEDING.,.aYou and We agree Ii arbitrate mtc all disputes. claims and controversies out aof or rclaling to I it N.DI It]I I 111( 11 It �,I \1 'N',I lttl \11 \1 Ilk PI I mlillf S A,,!Il rill R Off mll III I i Nim 1111 to IN I, 11 AMPIALIA IRM I IONI of 1) 1 ln'tAl It i't I All OR -1 In lfv0 NI I I\ I I",N I I I It A k\I I lf WAI\c It I Ol N 111 0 1 r IN W A 1) 1111 oil) 111 hn I R W V I RAN AI I \1111 1II I) B) lllll \'Ri I Nil \11 OR VAN N( I OR(1\111NII \ )k I A I \1 0( ( 1 lolm, 1\ ( O\V( HON link. A!ill )(,I Ill on) " Nim. 11 V 11,P� RI i i At, \\I) \Ottl 1 211 IONf1 I kA �j I\ \\N St I It k I \I%I IOR W AI Q 11 1) In R (M \"I m ( M 1 1) AND J In I III I. Ill M 11 K\(M OR AI Y'l I I 1 1) 0 1 AIAI I\ Not'R 24, \0I If I it \N\'ll II. ()IR \N} 1111 Ji I I I I (IIZ NRlRf Ili I it,\ h,"'A, I D NO I JI ANt, IN t jA\j I I IN \RNM,M I (.I OR 25.st IIN IN %I NI ....... IN M 1% N% HI I AI D 111 1104 vidtl I \11 NI \I'li% R, BR(It 0111 1 (IMMI M 1 1) Ol? 111 H) VOR[ 111 V, IA:l 1 1 1 26. ST 11.14%1111 111, '11 I \if \1 H M I I I I [`NCI DI \I (.1\1\1, k IS[ I t I Al I I ( I \1%I I - 011, .1 I)l It KVOAti I D61 I I I\I AVI Vil N I I )I\( I IN I�llA th., w"1", 1, Ali I II IA I IS N (i AIDI I If I\ \Ni) AI,A I I R \I ''" ' Imm "WNI' lo I N,I'] If IN 10 1 HILS NUKI I V I N I I ......... 'I A. td,Il- t , , alil —1, 18.11,01.)IMI I( I IDS 1, il, f"ll, I ",i'm pNimili'd b, ....... aly I,,W, 1,I" ) ll�I,I I I ,I," to I I id"l 11111 l. 1,]1.11 lc� I I V I'll, I Rt'l'i llA` I mid I...Id h,mld... (, I...I Oki, tillhat, tnlp A w P d x "I'd (till "Ild 1c,tch :1 overvIl le...... I imm ant and Ill Ihml parN Jain, (ill, .dmv I'a"itli'l, ill ill , "N and C cd "I ....... I Mill 111 it 11)—a. thl IL';l till', 11111)1 and I, ,,om kmd of nuto, Ill VIl1il—t1i0il 11IL11.t I I,b)ou r jr111,11, outllt,I I a ll, , i Ail cd ill,I I i,, "j,l) i v I vlicm� -11 ( I) ....... 111hul 1111111111duct P I A \0 I R 11. 111 iS ....10, / that 't I" VR mTC 41,1,tic.I i"I I I, 'Im, toil., 1" 11,111 itt ,I,pl\ 'PR J. L1,1H-rN) 11-11 NT?1, c%1, N I I M I I A I iAlll I) ON 11" I'll"' ii. ILIIIIAgl 1h1kI 11 lh hLI,,, it,, 'u'll third IotnN clom, l\IfW\IAI10A IN )I I[ k ( l"t DI r 10 P(it<I [`NDR %I f\G ..,kirr,-d,11 do ill c 11 1 Our c m1flo%%,ill 1 enll,11j,,;it %,tlLlr 11ropt,!1\ I I I',I ",(W \111 I ('1 RI M ( RI H RLY M11% OH I A IS No I did I'wh hill I"I dall,,v,"t, 101 -Lllli�ll I" tlIC IlInIC M4 W AA AR I I(1 1) 11 )1 nt I "I I I il I \[I I l R ( KI It Rl,\ 11 Ill '1111nd 111........ grit 'l 01 M AOI \\ 1 10 RI( I I\I PKI N( III I \1 1) 0111 K', 19-St BROC'I I It IN. ) ,t, I 0se in t alrrcd llct,,cli, oil ( RI I)l I I ROM L S \\D 0 1111 if (t 0,11,\Mt A. ( \1 I f.]it In"ll �111N 11:41(l" ill ;111\ (It La"ll" �MW tMnMh YM " h"I r , ((AS! Ml R 10 POR H\w V,I M 115 101 1, 1,1 0 1 W181 567- `Omo Iaijm, och ,, Caul In'll'olmo mlil",lilt, and You oeic, in A688:OR VA W" I \14 RM ON A L P0. 1115 914 NIA I dclold 1 , mh �Um) )()I vJk[j It) Nil It IS '501 1 It \NS( \I(A \\\It ktj Nil)\ \I It() ',IRA, ;"sl RAN( I 0 (11 11 IIN il u \Sl [it)\ 115 11() )I )\. 11 A I Ilf)k)I I Qt 11 \N Oil J(AA. CO 211. INTI.N1,111%IS ��D I%MI I?N Hit, I'll: Ii., I'L -'Ill I \\I (I ;01`4 R12', (i)any aspect of the minuonship between You and Us,whether based in contract,tort,statute or any other legal theory;(i if this Agreement or any other agreement concerning the subject matter hereof; (iii) any breach, default, or termination of this Agreement, and (iv)the interpretation,validity,or enforceability of this Agreement,including the determination of the scope or applicability of"this Section 5(each,a j "Dispute"). Prior to commencing arbitration,a pony must first send a written"Notice of Dispute'via certified mail to the ofFLrt'yy. The Notice t,Dls'(1O must describe the nature and basis fin'the Dispute and the relief sought. If You and We am unable to resolve the Uispme e•i it" n lhirl� (30) days, then either pony may commence arbitration. The arbitration shut[ be administered by JAMS pursuant to its Stre;unlinef Arhitrnion Rules and I'roce ur's unrriluFle a1: hit p//www.J'amsudr.cam/rules-streamlined-arbitration,the"✓AM11S Rules')and under the rules set(Doti in this'Agreement. The arbitrator shall be bound by the terms of this Agreement. No matter the circumstances,the nrbitralor shall not sword punitive, spanal,exemplary, indirect,or consequential damages to either party. If You initiate arbilm lion, You shall be responsible to p I 5250. All mtorncyys' fees,trnvcl expenses,and other costs of the arbitration shut[ he borne by You and Us in nccordnnce with the JAMS Rules and aI'plicable law. T'hc arbitration shall be conducted at a mutually agreeable location near Your Property. Judgnrnn nn an arbitration award may he entered in any court of competent jurisdiction. Nothing in this Section 5 shall preclude You to c Iron seeking provisional remedies in aid of arbitration from a coon of conipelentjurisdiction. NOTICE: BY INITIATING IN Till SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF DIE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUI ES"PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE, BELOW YOU ARE GIVING UP h YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS I; ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND T'HE FOREGOING AND ACRES TO I; SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE "ARBITRATION OF DISPUTES" PROVISION I; TO NEUTRAL ARBITRATION. ca,m,,,.n,l a,ml 16 l' IJWE AGREE TO ARBITRATION AN I)WAIVE THE RIGHT TO A JUBY TRIAL: I; 6.N'Ol'ICE'I'O CUSTOMF,RS I� A. LISTOF DOCIJMENTS TO BE INCORPORATED INTO'['HE CONTRACT: (i)this Agreement,(ii)the Additional Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. "I'hese documents arc expressly incorporated into this Agreement and apply to the relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY Oil COMMIT ANY BREACH OF THE PEACE I� 'I'O REMOVE GOODS INS'rA1.,LE:D UNDER'FIIIS AGREEMENI'. I C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALI.OF ITS PAGES. You acknowledge that )'on have read I' and received a legible copy of this Agfeeocat,that We have,signed the Agreement,and that You have read and received a legible copy of I; every document that We have signed during the negotiation. U. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to it IJ completely filled In copy of this Agreement,signed by both You and Us,befmc any work maybe started. l; E. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIIOR TO THE LATER OF: (U MIDNIGHT'OF THE THIRD (311ndl )BUSINESS DAYAFFER THE TRANSACTION NOT W F ICE OF CANCELLATION BELOW AN k PLAN OR ATION OF THIS HIGHTHE STARTOF ]'.INSTALLATION OFI'HE SYSTEM. SEE " THE I; I; VIVINT'SOLAR DEVEI i CUSTOMER(S): i L I� By; _ 13y: • Printed Name: Printed Name: Ki 1C/ W; Title: Q/� L_ By: I; Printed Name: ` l' Transaction Dale: �1 FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSA HUSE'ITS I, OFFICE:OF CONSUMER AFFAIRS AND BUSINESS REGULATION: TEN PARK PLAZA,SUITE 5170, BOSTON, MA 02116, (617)973-8700 OR 888-2113-3757. I; NOTICE OF CANCFLLA PION I� Transaction Date. AR No.: l; YOU MAYCANCLTHIS TRANSACTION ,WITIIOUTANY-PENAI rY OR0131ICATION,-WITHIN TH12FF ((3)BUSINESS I; DAYS OI rur, AliOVE DATE, OR-(IF 11IFR).,UNTIL IIIF.-START OV,INSTM-IALION OI IHL.5IS M—IF-YOU, CANCEI ANY' IROPEKTV TRADED IN ANY PAYMENTS MAIZE BY YOff UNDER THECONTRACT Off SALE AND ANY NFGOTIABLE INSTIIUAIENI' EXECUTED BY YOU WILL BI- RETURNED WITHIN TUN (III) BUSINESS DAYS I, FOLLOWING RECEIPT BY 'TIIE. SELLER OF YOUR C.ANCELIfA_ T10N NOTICE. AND ANY SECURITY INTEREST I. l; ARISING OUT'OF'['HET'RANSACT'ION WILL BE CANCELLED. IF YOU CANCEL, YOU MUST MAKE AVAII.ABU,'1'0 I, THE SELLER AT YOUR RESIDENCE, IN SUBSTAN'FI.AI_LY AS GOOD CONDITION AS WHEN RECEIVEII,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE. OR YOU MAY. IF YOU WISH, COMPLY WI.1.11 Till'. l; INS'I'RUCIIONS OF'IIIE SELLER RECARDINC THE RETURN SHIPMENT OF THE GOODS AT I'll E:SELLER'S EXPENSE l AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE 1'0•1'HE TI SELLER AND THE SELLER DOES NOT PICK T HEM UP WITHIN TWENTY(21) DAYS OF-[-HE DATE, OF YOUR NOTICE, OF CANCELLAON, Y'OU MAY RETAIN OR DISPOSE I� OF THE HE GOODS W'TTHOUT ANY FURTHER OBLIGATION. IF YOU FAIL.TO MAKE'FHE GOODS.\A'AIL.ABLE TO"FIEF. I. SEI.LER,OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO,THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATION'S UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, I; MAIL OR DF.LIVBIt A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE; OR ANY OTHER WRITTEN b NOTICE,OR SEND A TELEGRAM,TO VIA'INT SOLra,t DEVII,OPE R,LLC,Al'4931 N 300 W,PROVO,U-1-84604 PRIOR-I'D l; THE LATER OF: (I) MIDNIGHT OF THE THIRD(3 if BUSINESS DAY AE-FER 'TIIE TRANSACTION DATE,OR (II)THE. I START OF INSTALLATION OF TH E:SYSTEM. 1 HI;RI?BY'CANCEI.'1'I11S•TRANSACTION: Dale: Customer's Signature: I' i , :„A .il �.ux...41k.il�' I11 \'N. n.lt�v ..1 ♦i,.� , i I'1'\ _ . unlin�>_\.1, n a\I^.1\ilc�1\ini io�1 :. RI 1'IR H\1 VIIU11 \1❑ U\Wit\1111. It e 1: ' I : ...,,l ' e Il_LA1AI VI AI4F AIII ,I A'f rp!••vlr it I I I I I I I I I itIt . r If 11 J F I et 1 I I isl,.�•nfl rn,ndp 1, , &. 1• ."1 . + d u+ k A. I. 'I it \ 1 I:",11 rl U � 'h, 1• I, � F, 4., I- \,. ,u , 11• III I� a 1 •. .•Ih 1 I,oJ 1 11eUIt I 1I,ILL IFI JtiII U lu I 1 1 r l 1 I: -7b 41 I itA 1 1 h ,. Ill b{nl/ 1 it 1 . . 11 i t it n 1 ) it U�1 '1.•\11i11t Ill 11 I' II I 1 PJ'�. 11 r, I + l 11 ,nr.l I \ I I 1 .I .q• :, 1 .1., Bull, 11 '1... I It I L. 1,I: 1I w1 r I it u 1H 1. .JI rmk:+ u, II it II n III YI,� ) I) 1 I _1 ..I 1 v '.1 I A Ilm A ,al. I. e, 1+ ' 1 m It -I1 el :I I ,�eI ., I i I, ,. I 1 1,1, �I t 1 \1 \ Ll i I t 1 III 1,1 \ II 1. 1 I m 1t n , N: I, I It 11 I I I \Iw II III I 1t L, J I. 1 ..v y r 1 1\\.. I ,:.:u : \, �tl 1 i h ,I I, 1 p:n I F II , J, 1' J I. Ir 1 1 , 1 n II I n a I m 1 tl 1 1 S 1 1 urt 1 li u I v: h ; 1 , , ! 1t Ia vIl .. t I A , �1, 1 . hryn n'I° it I I 1 \J I \ , S 1 11 I LL I ,I III L t II,IJ,I e, 11 , I Yl ILI I- III, 1 I1 .1ti pot L1 +1 I _ ,1 1 i i I 11 rl 1 1 ! 11 11 1 u 1 I• 1 , 11I Iri11 1 III l - Irf♦ it UYuJ. 11 el 1 11 _ A + 11 1N'1 I,1 1 1 -1I 1. 1 I r,L, 11 1 I 1 J if,, , 1 0.1 ' I ' nl b., 1 , I <�. I IlL 1 1 U 1 I .1 AL O.. u I A 1 1 .I P 11 1 + Vt I ,11: !II b ! 1 he ul+.. • ,il,h,V. I1 , 1 d L. 1 1 q ll I •AI it,' , ,, tilt J 14. 11 it "V I I A' .,I. +e•,. V I In IA ,.I,I U, JIIII Fi IJ. 14.11AIIAMITIA. 1I , ,I, NIL + In .•I. .In,Tum, i J.,11 o II An 1 I ILL_ , I A, 1 1 1 l P I, I 1, 11 u„ V 1- rd 1 ,y 1A J' 11 1 f'I N 11 ,0 1 ill II \ 11` 1 U i 0! rt 1 h \ l I 'h J+ A A11u„ { A , I YI I I Lit1111 n Ili IuIl e II , I 11 II '1 I I Il I L L a I If,he 1' 11AA', n l I it p III' Id II, I I A 1. rk 1 II 11 tl : 1 1 NIL L 111 I. If., A l fn !1 I .. L I I 1 1 1 t AI II I 11 1) 1 Il it •� n Ih 11. a li 1A II AI 11111011AAA1 1 r 11,1 I II 1 11 I_. lu, , 1 1 r 1 1 I' 1el I I I1 AA I I I I I I I LA I, 1 I p' II Ir I I II-'I I I L k he 1 1 ".. 1 I :. I I I I 1'11,1 it1 •. :1 1 I I r 1 1 1 J "1 1 Ill r u , 1 it I 1 1 1 ) 1 , 1 h I 1 I 1 I I f, t) I 1) ' 11 I ♦ 1• it 1 1 11I 11 1 111 1 ,1, 1 , 1 111I , A Il. lu \ 1 If 1 IJ ' 1 I r l 1I d1 If I 11 u , a u .. IiI u, l-a I. , —1 V l u , 1 1 11++Ik.u1( 1 1 el 1 , 'n w 1 ...,M II r•, a 1h 1II 16 1 1 III :. U, �I ,.. _., , it., I.•. _.,,I t 1 1 1_ ( ,Ill 11 „ I I 1 1 1 AII I , !� 1 I e I I I t I ( 1 1 t i t .I ih. 10 AII nl lul AIflAI IU1 1 I , B ,I a I I n AA A „� , I ,- 11 I I I II• I l l n 1 .II I I 1 1 t,J I t., Ih, II 1' VnII I 111 I 'I : II 1 I' cl: 1L 1 , , I .I+ d I 11'.n 1 1 IIJ 1 1 I Ir. I I Il .l�u dd � 11 +�II 1 li i It U 11 II f I.1 '.1 II S . f 1 1 1 1 I. U 1II 111 '.I ,I 1 + A Il I.I 1 ,I PII ti d I 'I ell I 1111111d 1 I _11 ill x F I„1 1 L I 'I 1 1 I 1.1,:. 1 I d 11 , ,Ill I1 1+r I+.I: „I , 1 u + I - ,I 1 \\ 1. p , I- Ile F, )' I L , I fl .III \ J 1 fill , I II I .I II P vl I -i `1 n,+ I is 1 .111 .11 II Y„ a II' I I. I1 ( 11 1 ,, 11 II r 1 1 11.. I I I q 11 , I 1 ' I , I ') 1 :- I ul. I 1. I I t - I, - J.11 L I .I ' lou ( I 1�. b AAY IItAII I, II - 1 A( I L el I I I I II . UV I AI 11 I , V AA1V1 111 AAI IA III IVI( Il lull llll Rl A '� 1 Jn i, 1 II,❑c. II lill 11 IIA it pl VA1 'I It lnp olt ,1 rn111N111 AA.,':e+� 11 1� It1k 1 Al etPI HI I,Y VA; :, 11,to 1'd.,+ J.c•�i: . r ;� 11 1I I I=L I 1AA 11 W . .1 .,I. ,I I AI 1 + tl 1 h 1I I 1 11 111 1,II h1 A , I I NI I II11 :r I FI 'I "'err, It I I k Let, 1"1"ILI 11 1Ih I 1 1 ,h II„ ,... 1 11 1 _ I, LI1 Ia III ONVI 1IV111N III 1' 11';AI +e:,l uw nI ,, At..l_1 m, .1 II1 I,•1 I,II It II 1 Y \ 1, full +,II. d L 1I ,I 1 . lu, IIh- 1 Jai 1 1 11 1 Ii 11I 1 Y {1' I. II,,IA: 1 .I I t I 4 �,hI. 1., .,L1 :I I' 1 1 1 I h, t l u1 i . 1 1 1 ., 11 I. t l l I 1 II 1 A k p 1 1 I p1 1 n i q I t:, ..I •: I I I,� 1 1111 1 I 11 a 1 . fettle 11. 1 1 1. 111 1. o ) 1.1 7 I l. . I I , I k 0 ,, .IIy !III, V 1 \ n 1 n 1 I1 AA I I l I I I 1 11 If 1 1 1 1 P 1•. L.II , .1 IFII I l 1 Ih I I, 1,111 Ip. .r l l l 1 ( r e, l I 17 1 Iu, n f b 1 q. •u r. ,r u' F I I 1 I lI If l - 1. 1 1 : n 11 1 1 1 I\ I I \ 1 I1. I IJ\III \ 11)\UFIIUtll I11 1 I I ', \\ _i + O 1 f ,I t I \ I II I I le 1 -• 1 m if l y t 1 , Ill 1 Vv S. 1 I lh II 1, Ir A r 1 1 n V 1 If 1 e \ 11 lI I fo ,11 1 PILL,I I + 1 IV 1 •IL 1. f Ik I':' ItIi vp I II U 1 1 I II I I I . �1 1. .. ,1 I tt, 1,11.I I It L Iii l +t.. _al ,.. I I,1 't h1 F. l.y o 1' ,il l h. ¢,.1, 1L I IP,r .I.. ,rl,.I I I l :. ,h11 I. tl 1 I r IItI,Id II 1J '\ VI II 1n 11i I,.nh II r .II Iry ni ul ..io lBrLxl1 1r <.lu, „ .n. 1 e+: I . I lx - rl n A I :h,i, ', ,.,'Ill n I 1, . 1 .1111.,1 •1 V a[ n , I 1 1,.. 11. 1 - Il ,x i' V(>IUC11111 AAI)IA( \\S l,81 V 11 UI- IMet V iRtlI AlhV1, kt ) 1 .n• 111t A. ,m l 1.1 .� v:1 �J ,,� M,1"k,I ,;,.i 4A1 I:AIll RI 111 I11 S)IIIALIif 1A1 AI I,UOIAI Vlr 6r1 1 11nP (''AI 11.1) AAY IAJI'Itl' f)R I.IISV INIII I R _ R. v 11i 1vII AtI a nl L It v ,v I o, I it I RIT L11AI Al I I•I RY AI_ IA!II 1<1 f)OR III 4I III I 1 I _..x i' 4AA UAI . AA1 AA'U 1'Of It RII III.AI IAILIt etIII tine v ,t „I I I m 1 1,1 1AII R1 1111 I.I)S1 VA A* l Al If I) liV' 4 PARI}"ti 1 IIn1S 1hd 1 u t a I '.I ILL I I,PAt f. 111AI I]. nit VAIIII AII.R1 "[ IIf V,n 1111 rr• ,I 1 ^t 1 •� PARI I.IAI111111 ARNNI: UI I'Iif OR RI:I AIIMI I i mu11 1 , 'r .qua, L II, 1 J: "'I 11 I,_ •I a F pf I I n1r, I'd r . :1 IIIS Vt,ltl bA11 A I n1111 I 11 hU I A h.A I I At 1 1) 1111 5 : 111 1 L. fl I,:.. 1 I ,t'. I)11 AI I I kA1A11AI 1-Ul AAI1 RI itIR11 1111I 1111R 1 .n , a1vv 1 ,�•.I 1 I � . l , lblt)1 AI A4I1 I R If 1 Irk i"111A I I(IAI)I IIII I I V I 1 IL �+, 1 v 1 .n„ I„ IILAI 1UL IIR \A I I-APIY T CU IACI R IA I III l A<I tlI AA1 1 111.'1 ,I, r r I. h1 Ihr Aa I pn 11 AII I q IN ,1 :.L. I 11.,+.I,._I. 11J11tVi112I()titi Ill ltli VDIJt. nrrl IIy 11v I�, 1 f , 1 1 .1 v.r, 1 n,l111.AIM III 111 I III %I A1A Ill 11)( .%(i.AIACI l 1l)R A\Y 11 qnu, Irn.6rc, ,11 ,e+ n,n A +u•I-.Im 1- 1 I�.ci.0 11: vovonth solar 3301 North Thanksgiving Way,Suite 500 Structural Group Lehi,UT84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scott.wyssling@vivintsoler.com December 18,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services ODonnel Residence 9 Hillside Ave, Salem MA S-4092655 4.845 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 8 dimensional lumber at 16" on center with 1 x 8 collar ties every 48". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category 'B" and 20 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per(ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint. solar Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 20 PSF=Live Load (ground snow load) • 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 '/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64" o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve trulyyours, tNOFMac„ cwl w Scott E. Wys42 si PE ° 50 MA License N . 50 90 FGISTEQ� FFSSi0W. boeont. solar 9 HILLSIDE AVE, SALEM MA 01970 c ¢om ( 5'OF V PVC CONDUIT _ FROM JUNCTION BOX TO ELEC PANEL I J ~ N� JUNCTION BOX ATTACHED T I m ¢ ARRAY USING ECO HARDWARE TO KEEP JUNCTION BOX OFF ROOF I 0 PV INTERCONNECTION POINT, PV,,1SYSTEM SIZE. I O = LOCKABLE DISCONNECT SWITCH, 4.845 kW DC ) ANSI METER LOCATION, &UTILITY METER LOCATION N 0 .o � mo $ 2 > Z E m Z W .. I I W W Z m J W 2 3 _ _ _ _ _ _ _ Al__________ _ N y ¢ 2 2 � SHEET NAME: wg � a (19)Tnna Solar TSM-255 PA05.18 MODULES WITH Enphase M215 D-2LL-S2x-ZC MICRO-INVERTER SHEET MOUNTED ON THE BACK OF EACH MODULE NUMBER: PV SYSTEM SITE PLAN o SCALE: 3132"= V-0" > a � y m z O M H am NA p0 O 00� p c vm� m = z ti y O O Om 3 m N z z z c> m c i N z op z O A OO pc m y D C $�,8o m Cl) yip _ �3 Ln C ogn 0 m o � ' O O m r D Z �= Di INSTALLER VIVINTSOLAR . ODonnel Residence �m ROOF mm INSTALLER NUMBER:1.B77.404.4129 ��.yp wig` �(M��,f �r.�y 9HILLSIDE AVE PV 2,Q A~ MA LICENSE:MAMIC 170848 �/ V aY Y Y. ©IIA� SALEM,MA 07970 PLAN DRAWN BY:BRG AR 40926! Lasl ModiFletl:12IW2014 UTILITY ACCOUNT NUMBER:38248-D1008 CLAMP m MOUNTING SEALING c PV3.0 DETAIL WASHER m LOWER SUPPORT <om � ¢o PV MODULES, TYP. MOUNT OF COMP SHINGLE ROOF, FLASHING 0 PARALLEL TO ROOF PLANE / 2 1/2" MIN O 5/16"O x 4 1/2" MINIMUM PV ARRAY TYP. ELEVATION STEEL LAGTSCREWS NOT TO SCALE TORQUE=1312 ft-Ibs O CLAMP ATTACHMENT V) NOT TO SCALE 0 a •o ? CLAMP+ ATTACHMENT CANTELEVER L/4 OR LESS oC COUPLING ol L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. m N PERMITTEDCLAMP+ - COUPLING g m o $ ATTAC MENT CLAMP CLAMP a m w COUPLING SPACING PHOTOVOLTAIC MODULE m w .. W Z F F j 3 N m Q SHEET NAME: L=PORTRAIT tp CLAMP SPACING Z =) < O ECO 2 L=LANDSCAPE MODULEIBLE PV SYSTEM MOUNTING DETAIL SHEET NUMBER' CLAMP SPACING (MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE a Inverter Ratings(Guide Section 4) Irnrener MakNMMel Enpbax M21550-ALIT Pz-ZC O Conduit and Conductor Schedule MODULE DETAIL Max DC van Ruling as vplm T.g Dv_, , Al. eve. amco e..m. c.m,,.Typn cm,wasv. Max I.—O4g°C 2t5 Went , E.,p,.a,on a.wN..Tmvwz uxwG c.m re.Al� V coo NominelflC Village 240 V01M , sere CmGer GmuM tEGGGECI a.. WP-1..P - riah, Trine Solar TSM-255 PA05.18 Max AC Current "I AMPS to Pwo ar C SOLAR MODULE Max OCPQ Rat w Evans 2b Amps x rnn-z we Q v Max Numcerpr Penemciuu ,? x r"w";-G'un0 p-'' '♦3 oi we T.2 N tu o'm" NOTES FOR INVERTER CIRCUITS(Guide Sec8on8antl ef: a Trivial-x-Gm,ub axwc r we �Qow m 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings @ STC(Guide Section 5) 020 Enchaser M215-6(1-2LL52x-2C SWITCH MEET THE REQUIREMENTS? 55 Z MICRO-INVERTER AT YES NO XNA Model Makerhodel Treat Solar MM-255 PA05.18 J F EACH MODULE ATTACHED Max P..'Poinl Current(Imp) 8A6 Amps taZ , N z J 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max PowerPoim Voltage rymp) 30.5 Valle <p WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? Open-0nofit Voltage Noc) 37] Vora 0 YES NO X NA U Shl rt-Cimuit Cwrent d.) 8.92 Amps O >< ax 3.)SIZE PHOTOVOLTAIC POWER SOURCE DC)CONDUCTORS M Series Fuma QCPD) 15 Ampe F BASED ON MAX CURRENT ON NEC 60.0 SIGN OR OCPD Nominal Maximum Power at SIC(Pmax) 255 Wage MICROINVERTER CONNECTION RATING AT DISCONNECT. Maximum System You, 1o00(IECy600(UL) O j TO ENGAGE TRUNK CABLE A)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING voc Temperature coe8mient oat WC ^ TO INVERTER OCPD AMPERE RATING(Sea Guide Section 9). V S.)TOTAL OF 2 INVERTER OCPDde).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING feeble Section 6 and 8 and Appendix of, PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY L WITH 120%BUSBAR EXCEPTION IN 1 J Lowest expected ambient temperature based on ASHRAE minimum mean extreme NEC 69064(B)(2)(a)? XYES NO dry bulb temperature for ASHRAE location most similar 0 installation bcaeon: -19-C (G BAREROUNDIN (GRO CLI UNDING G ARRAY) Signs(See Guide Section 7) son,aaturefrASTIRAE beat tnmpemturearbased 0 installation ASHRAE highest 39month 2%tlry bulb temperature far ABHRAE location most similar m insWllaBan location: 39°C Sign for inverter OCPD and AC Disconnect 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47"C in the v, United States(Palm Springs,CA is 44.1°C).For lass than 9 cumdntrarrying conductors Solar PV System AC Point of Connection in roof-Tounled sunlit conduit at least05-above roof and using the outdoor design AC Ought Cunent 1 17.100000 Amps temperature of 47°C or Was(all of United States). rram�•� Npminel AC V(IWge I eu Volts a.)12 AWG,90°C conductors are generally acceptable for modules with lsc of 7.68 Amps Y < THIS PANEL FED BY MULTIPLE SOURCES w or Idea; hen protected by a 12-Amp or smaller bee. (UTILftt AND SOLAR) orb.)imA en pmte W by ors aregenerally par smallacceptable for matlules with lsc of 9.6 Amps 10 a or less when mtetletl a1SPm orsmellerfuse. •� NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY •Q ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR me a an PV CIRCUIT 1: 70 MODULES/PARALLEL et ENVOY BOX < te . oi Sedum m % e 10 • • • O O /^\ 1 WP ~ ed }I{I E < U E 1.0 MURRAY POINT OF DELIVERY > w m ./r ✓` ✓` COMBINER AND INTERCONNECTION w w z do PANEL 125A/240V SIEMENS Q Q _ 3 \G G LW004NR 60AI240V H H I PO\`pR 2G do OR EQUIVALENT UNFUSED NEMA3 M z z o I OT\�-/-�(n t SREC/ANSI LNF222R OR SHEET PV CIRCUIT 2: 9 MODULES/PARALLEL I o\* c - EQUIVALENT Oq\�P( METER NAME: I \O EXISTING lto • [a- V zoo 240V1200A WLOAD-CENTER JM �,• • • 3MSHEET ___ __ ____ ____ ______A__ _____ _ _______ __ NUMBER' ____ ___ _______ ___ ____ ____ • - \\ MILBANK VISIBLEILOCKABLE 1_- JUNCTION BOX '2 \\ 3 100A OR '3 'KNIFE'A/C 3 O NEC 2014 Compliant WITH IRREVERSIBLE E 1 0 \ EQUIVALENT DISCONNECT R GROUND SPLICE \ E 1.0 U6934-XL-BLG E 1.0 E 1.0 W 3 C O N D y 0 � o m �° O Om N y UI z <z x O oD Z 1 f` A d, O 3 2 L) m Cm Zi INSTALLER:VIVINTSOLAR ,,,,JJJJ���� ODonnel Residence `M DESIGN M1^ INSTALLER NUMBER:1877.4044129 �ap,d'o17C1� �/�\I�� PV 4.0 9 HILLSIDE AVE p LOGIC m MA LICENSE:MAHIC 170848 u Uu u solar SALEM,MA 01970 DRAWNBY:BRG JAR409261. Last MotliW 12/W2074 UTILITY ACCOUNT NUMBER:38248-01008 Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Kevin Odonnell Project Address: 9 Hillside Ave,Salem MA A.System Description: The array consists of a 4.845 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(19) 255-watt modules and(19)215-watt micro-inverters,mounted on the back of each PV module.The array includes (2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C.Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: . Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules - , 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrium Solar b.Product Name: Eeorail c.Total Weight of PV Modules and mounting hardware: 893 Ibs d.Total number of attachment points: 46 e.Weight per attachment point 19.41 lbs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 334.59 square feet h. Array pounds per square foot: 2.66 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (19)modules,(46)attachments 19.41 pounds vivin#. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 255-PA05.18 19 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.36 amps Ise-rate short circuit current - 8.92 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21-L.-S22 19 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 10 modules/inverters (15)amp breaker PV circuit 2 - 9 modules/inverters (15)amp breaker 2011 NEC Article 705.60(B) vivint solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 9 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 11.25 amps 2.Overcurrent protection device rating PV circuit continuous current rating 11.25 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.6003) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°P) 71% 2011 NEC Ar¢de 705.60(B) Adjusted PV circuit continuous current 15.8 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors ', Conduit fill derate factor 80% 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 12.6 amps Total derated ampacity for PV circuit 12.6 amps Conductors(tag2 on 1-line)must be rated for a minimum of 12.6 amps THWN-2(90°C)#14AWG conductor is rated for 25 amps (Use#14AWG w larger) 2011 NEC Article 705.60(B) 4.Voltage drop(keep below 3%total) 2 parts 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.48% The largest number of micro-inverters in a row in the entire array is 10 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.48%. 2.AC conductor voltage drop: =1 x R x D (=240 x 100 to convert to percent) = (Nominal current of largest circuit)x(Resistance of#14AWG copper)x(Total wire run) = (Circuit 1 nominal current is 9 amps)x(0.0031952)x(170� +(240 volts)x(100) 2.03% Total system voltage drop: 2.51% vlivin#. solar EcolibriumSolar Customer Info Name: Email: Phone: Projectlnfo Identifier: 18727 Street Address Line 1: 9 HILLSIDE AVE Street Address Line 2: City: SALEM State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-255 PA05.18 Module Quantity: 19 Array Size (DC wafts): 4.845 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 44.8 Ibs Module Length: 65.5 in Module Width: 39.625 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: 11 Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load - Lateral: 288 Ibf EcoX Design Load -Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load -Lateral: 233 Ibf Module Design Moment— Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 r EcolibriumSolar Plane Calculations (ASCE 7-10): R1 Roof Shape: Gable Edge and Corner Dimension: 5.45 ft Roof Type: Composition Shingle Stagger Attachments:Yes Average Roof Height: 20.0 ft Include Snow Guards: No Least Horizontal Dimension: 54.5 ft Roof Slope: 20.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.91 0.91 0.91 Roof Snow Load 30.6 30.6 30.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description - Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 30.6 30.6 30.6 psf Downslope: Load Combination 3 10.7 10.7 10.7 psf Down:Load Combination 3 29.3 29.3 29.3 psf Down:Load Combination 5 11.9 11.9 11.9 psf Down: Load Combination 6a 29.8 29.8 29.8 psf Up: Load Combination 7 -10.2 -17.7 -27.3 psf Down Max 29.8 29.8 29.8 psf Spacing Results(Landscape) _ Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 59.7 59.7 59.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.9 19.9 19.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 36.4 36.4 36.4 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 12.1 12.1 12.1 in EcolibriumSolar Layout Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriurnSolar Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 851 Ibs Weight of Mounting System: 92 Ibs Total System Weight: 943 Ibs Total Array Area: 342 ft2 Distributed Weight: 2.75 psf Number of Attachments: 46 Weight per Attachment Point: 21 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 46 ECO-001_102 EcoX Coupling Assembly 22 ECO-001_105B EcoX Landscape Skirt Kit 9 ECO-001_105A EcoX Portrait Skirt Kit 0 ECO-001_103 EcoX Composition Attachment Kit 46 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly 1 ECO-001_106 EcoX Bonding Jumper Assembly 5 ECO-001_104 EcoX Inverter Bracket Assembly 19 ECO-001_338 EcoX Connector Bracket 19