Loading...
347 HIGHLAND AVE - BUILDING INSPECTION (4) C11Y OF S�LEtit PUBLIC PWPEWN DUARTUEM maws »er s.rotarsn..r.suoaxe..oarn.a+os t+.�+>iW.a�aari.r..s1►t..+w cossumdom Deeds Chip -1 Affidavit book"6 dlde.reudas.et r..sysdas Woo >y aoow"m wI&dw dXlk OMos alms sb t ft3 tas Co ft 70 CMZ s.adm tit.! O&^mddwp m. I LR IsdumsAs!r 8uUmm rsmdt r H lmd u tm m.aoeama.*Ado&bb names fto WM wa&*A bs Rood diS s 11119 % llama/srnM dhpmd Adft as dWsr by MM s t t t.s tlQl1. ' Tts debrb wW bs trsmp4Md by pre etlrMr/ The debris will be dfapo$W atilt: *Mae (aldaer of hsiWpj GIs /o°1 sror AFFIDAVIT ARCHITECTURAL DESIGN Permit No. To the Commissioner: Re: Northeast Animal Shelter Ward I certify that to the best of my knowledge, information and belief, the plans and computations accompanying the attached application concerning the locus at 347 Highland Avenue Salem, MA Ward are in accordance with the requirements of the Massachusetts State Building Code and all other pertinent laws and ordinances. G\S�EFEp ARCy/ AR H T- MASS.7. NO. 3386 A_ y F William A. Yuhas o COMPANY MARBLEHEAD, ti Architect p2` MASS. JyW ADDRESS ' y'�JH 0 MPSSp4 80 Lafayette Street, Marblehead, MA 01956 PHONE 781.631.7039 Commonweal of Massachusetts County of dam_On this_�day ofa4e C/ 0 d ,before me, the undersigned notary public,personally appeared 11l rA lie WJ6= proved to me through satisfactory evidence of identification,which were Personal I{nowledpe to be the person whose name is signed on the preceding or attached document,and who swore or affirmed to me that the contents of the document are truthful and accurate to the best of his/her knowledge and belief. Before me, My Commission expires NEAS.C.C.ArchDesgin.080107.doc McBrie. LLC 160 Sylvan Street l \/\/\/\%\/\/ Telephone: 978-646-0097 Danvers, MA 01923 y Structural Design & Sales Fax: 978-646-0087 www.mcbrie.com AFFIDAVIT STRUCTURAL DESIGN AND INSPECTIONS TO: Mr. Peter Beaudoin Groom Construction Co., Inc. 96 Swampscott Road Salem, MA 01970 RE: Northeast Animal Shelter 347 Highland Ave. Salem, MA McBrie, LLC Job#: 7-017 I certify that to the best of my knowledge, information and belief, the plans and computations for the captioned building modifications was designed in accordance with the structural requirements of the 6d'edition of the Massachusetts State Building Code and all other pertinent laws and ordinances. I also certify that I, or my authorized representative, in conformance with Section 116.0, Construction Control, and Section 1705.0 of the 6a' edition of the Massachusetts State Building Code, will inspect the work during construction. This will include the inspection and review responsibilities outlined in Section 116 and as indicated as SER on the Program of Structural Tests and Inspections. We shall also oversee the testing agencies and will require all tests reports be submitted to our office for review. Upon completion of the construction, a Final affidavit indicating that the Program of Structural Tests and Inspections submitted for permit have been satisfactorily completed and all discovered defects have been corrected will be issued upon request. No. 41143 mw of M Structural Engineer MA Reg. No. �O b o H AMm 160 Sylvan Street, Danvers, MA 01923 WTURAL y Address No.41143 �TEP� (978) 646-0097 FSS oN LE" d6/e 7 Telephone Mt McBrie, LLC 08/06/07 Structural Engineers Date 7-017 Affidavit-Design and Inspections.doe Page 1 of 1 CITY OF SALEM FIRE DEPARTMENT - FIRE PREVENTION BUREAU 29 Fort Avenue �c Salem, Massachusetts 01970-5232 8e (978) 745-7777 _ 'ERMIT TO INSTALL: Date 'prinkf er and/or Standpipe System .)wner'st4ame: i3Or !'i� Tstaller's Name: permit is hereby granted based on approved plans,to install the system designated above. All plans are approved solely :)r identification of type and location of fire protection devices. All plans are subject to approval of any other authority aving jurisdiction and issuance of a permit by said authority. Upon completion, the Installer shall request a test and file a :ertificate of Completion or Inspection_/ fuM1 locelbn sY alieel end no.,.,dexnbe In such manrwr ss b povlde adeQuAe ide MKcelbn e(brelbnf IOTICE: CONTRACTOR TO REQUEST FINAL INSPECTION. sae ,a �sh9� his Perrn t will expire �/0 (THIS PERMIT MUST BE CONSPICUOUSLY POSTED UPON THE PREMISES.) >rrn 991E (Rev 9ry7) t EI`ZOF PUBLIC PROPERTY a DEPARTMENT KIMBERi.EY DRISCOLL MAYOR 120 WASHINGTON STREET 0 SALIE .MAssACHLSka-M 01970 TEL 978-74S-9S9S R FAx.978-740-95" APPLICATION FOR THE REPAIR, RENOVATION, CONSTRUCTION. DEMOLITION OR CHANGE OF USE OR OCCUPANCY, FOR ANY EXISTING STRUCTURE OR BUILDING 1.0 SITE INFORMATION Location Name: Building: Property Address: Z47 H-%a#441V2a Av,=A/0 = qsu Aff'Y7 , 114 A 0/9,70 property is located in a; Conservation Area YIN Al Historic DisMct Y/N /V 2.0 OWNERSHIP INFORMATION 2.f Owner of Land _ Name: W,6Z r#E'A---�T .dNs�-sr9 L Stl LTL �no� , Address: 5417 1.1z4:57d/4AAjz> .AV/ IILE' AIA Q/9 70 Telephone: 9'78 -• r24,& - 9f3S 8 3.0 COMPLETE THIS SECTION FOR WORK IN EXISTING BUILDINGS ONLY Addition Existing / Renovation y/ Number of Stories Renovated / Change in Use New / Demolition Existing /3;000 +/- Approximate year of Area per floor (sf) Renovated 8 600 '1 /- construction or renovation of existing building New 5. 000 +/- Brief Description of Proposed Work: f-=7= 0,gr AAF4,0 4c!')2/J' r✓C'sx�a-rlcvcT�orJ .c5 ti! x�'s;-zA�i Q Ji/1 /*7,04- l✓br�rat �sr AA1i7, �— -- -- Mail Permit to: tg0t0Y1✓7 i yt�rio �1� S�-✓err co r- /�ox� ----- What is the current use of the Building? �/✓O CCU Material of Building? "d"RONZ Y If dwelling, how many units? M�r4 Will the Building Conform to Law? �� Asbestos? A/M Architect's Name /� LLZANt ,Q ' f�Llf/OS So GRs� j78/-d;3f- 703q Address and Phone , AdA Mechanic's Name Address and Phone 26 ;SGt/Am PS•G Ate" Construction Supervisors License# 040379 HIC Registration# Estimated Cost of Project$JOr 000 Permit Fee Calculation Permit Fee$ 14, --To s-• Oo Estimated Cost X$7/$1000 Residential Estimated Cost X$11/$1000 Commercial An Additional $5.00 is added as an Administrative charge. Make sure that all fields are properly and legibly written to avoid delays in processing. The undersigned does hereby apply for a Building Permit to bull t e above stated specifications. Signed under penalty of perjury /� Date 8 a �I yz J N N a 9 ti, 1 I Fire Suppression Inc. For excellence in fire protection PROPERTY AT 347 HIGHLAND AVE. Salem, Mass. THE BUILDING IS TO BE OCCUPIED BY A PET CENTER/ANIMAL SHELTER 780 CMR 903.1.1 FIRE PROTECTION NARRATIVE REPORT 903.1.1 (1.A) BASIS (METHODOLOGY) OF DESIGN SECTION 1 — BUILDING DESCRIPTION a) Use Group: B, Business, b) Number of floors above grade: One c) Types of occupancy (hazards) within the building: Ordinary Hazard Offices , Service Areas d) Site access arrangement for emergency response vehicles: Existing e) Building wall construction: Masonry— Meal Deck Roof. f) Building height under 20 feet SECTION 2—APPLICABLE LAWS. REGULATIONS AND STANDARDS • 527 CMR— Fire Prevention Regulation 24.00 • 780 CMR—The Massachusetts State Building Code, sixth edition; Section 906.0, 915.0, 917.0, 918.0. NFPA 13 Standard for the Installation of Fire Sprinkler Systems NFPA 25 — Inspection, Testing and Maintenance of Water-Based Fire Protection Systems NFPA 72 — National Fire Alarm Code SECTION 3 — DESIGN RESPONSIBILITY FOR FIRE PROTECTION SYSTEMS Fire Sprinkler System Ellis Fire Suppression Inc. 10 Brandt Drive Woburn, MA 01801 781-389-6921 1 Tel: 781.389.6921 10 Brandt Drive, Woburn, MA 01801 Fax: 781.933.0988 ty , (page 2) SECTION 4— FIRE PROTECTION SYSTEMS TO BE INSTALLED Automatic Sprinkler System Description: The building is to be equipped with a wet pipe sprinkler system covering the entire building. A hydrant flow test was taken prior to design and the results so Noted on the sprinkler design drawings. Design responsibilities: The professional engineer (P. E.) will design the sprinkler system as per NFPA 13 2002 edition and specified the fire protection system to be installed. He reviews and approves the installation. The P E is considered the engineer of record and certifies the installation for code: 903.1.1 (1.b) SEQUENCE OF OPERATION SECTION 1 Wet-Pipe Automatic Sprinkler System: Heat produced from a fire melts the fusible element in one or more of group of sprinkler heads. On a wet pipe system: The sprinkler head(s) is opened and water is immediately discharged to control the fire. Water flow alarms are tripped upon sprinkler flow indicating an alarm condition. Water will continue to flow from the open sprinkler head(s) until the valve serving that area is manually closed. Fire Alarm System: The operation of the wet valve shall automatically ring a local alarm bell and forward a signal directly to the Fire Department. 2 (page 3) TESTING CRITERIA SECTION 1 —TESTING CRITERIA The system is equipped with an inspectors test valve located at strategic location able to generate a flow of water equivalent to one sprinkler head which should generate an audible and or visual alarm. NFPA requires a minimum of yearly testing and certification following the procedures outlined in NFPA 25 with documentation. Acceptance test criteria shall be per NFPA 13 and NFPA 72, and shall include but not be limited to: 1. 200 psi, 2-hour hydrostatic testing of the sprinkler system piping per NFPA 13. 2. Not greater that 60-second response time on flow switches. Recommended response time of flow switches of 30-45 seconds`. 3. Tamper switches to ring supervisory when partially closed`. 4. Verified Notification of Fire Department of alarm signals*. - optional; may be done at annual fire sprinkler test. SECTION 2— EQUIPMNENT AND TOOLS All required equipment, tools, and literature shall be supplied by the appropriate contractor at the time of testing including, but not limited to: • Manufacturer's literature • This approved Narrative report • Flow measuring devices • Gauges • Communication radios • Hydrostatic testing equipment SECTION 3—APPROVAL REQUIREMENTS The following shall be supplied to the Fire Department upon final completion and acceptance of the systems: • Name, address, and telephone number of installing contractor for each system • Contractor's Material and Test Certificate END OF NARRATIVE 3 HYDRAULIC CALCULATIONS FOR NORTHEAST ANIMAL SHELTER 347 HIGHLAND AVE SALEM, MA. 01970 DATE: 7/19/2007 -DESIGN DATA- OCCUPANCY CLASSIFICATION: LIGHT HAZARD DENSITY: . 10 gpm/sq. ft . AREA OF APPLICATION: REMOTE 900 sq. ft . COVERAGE PER SPRINKLER: 120 sq. ft . NUMBER OF SPRINKLERS CALCULATED: 11 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 182 . 8 gpm _ TOTAL WATER REQUIRED (including hose) : 282 . 8 gpm FLOW AND PRESSURE (REQ' D @ SOURCE) : 282 . 8 gpm @ 27 . 5 psi FLOW AND PRESSURE (AVAIL.. @ SOURCE) : 282 . 8 gpm @ 79. 6 psi SPRINKLER ORIFICE SIZE: 1/2 inch SPRINKLER K FACTOR: 5. 6 K CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. TUCKER, GA 30084 aa� yes__`,,_ _u..•, e o JAn1:Es 4 McHUG1 ` cr FIRE PROTECTION � NO.3B572 �?ISlF � \ r^r SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/20/2007 E : \SPRINK DESIGN\MB\NE ANIMAL SHELTER 7-19-07 .SDF JOB TITLE : NE ANIMAL SHELTER WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ' D NODE PRESS . PRESS . @ PRESS . @ DEMAND PRESS . TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 80 . 0 75 . 0 1090 . 0 79 . 6 282 . 8 27 . 5 Available pressure is 52 . 1 psi (1900) greater than required pressure . AGGREGATE FLOW ANALYSIS : TOTAL FLOW AT SOURCE 282 . 8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100 . 0 GPM OTHER HOSE STREAM ALLOWANCES 0 . 0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 182 . 8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 2 . 0 SOURCE 27 . 5 182 . 8 2 2 . 0 - - - - 27 . 4 - - - 3 2 . 0 - - - - 27 . 4 - - - 4 2 . 0 - - - - 21 . 9 - - - 5 10 . 0 - - - - 18 . 0 - - - 6 12 . 0 - - - - 11 . 4 - - - 7 12 . 0 - - - - 11 . 2 - - - 8 12 . 0 - - - - 11. 2 - - - 9 12 . 0 K= 5 . 60 8 . 0 15 . 9 10 12 . 0 K= 5 . 60 7 . 3 15 . 2 11 12 . 0 K= 5 . 60 7 . 1 14 . 9 12 12 . 0 K= 5 . 60 7 . 0 14 . 8 13 12 . 0 K= 5 . 60 8 . 1 15 . 9 14 12 . 0 K= 5 . 60 7 . 4 15 . 2 15 12 . 0 K= 5 . 60 7 . 1 14 . 9 16 12 . 0 K= 5 . 60 7 . 0 14 . 8 17 12 . 0 K= 5 . 60 8 . 2 16. 0 18 12 . 0 K= 5 . 60 7 . 5 15 . 3 19 12 . 0 K= 5 . 60 7 . 2 15 . 0 20 12 . 0 K= 5 . 60 7 . 1 14 . 9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/20/2007 E: \SPRINK DESIGN\MB\NE ANIMAL SHELTER 7-19-07 . SDF JOB TITLE: NE ANIMAL SHELTER PIPE DATA PIPE TAG Q (GPM) DIA(IN) LENGTH PRESS . END ELEV. NOZ. PT DISC. VEL (FPS) HW (C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 182 . 8 6. 280 PL 38 . 00 PF 0. 1 1 2 . 0 SRCE 27 . 5 (N/A) 1 . 9 140 FTG TG PE 0 . 0 2 2 . 0 0 . 0 27 . 4 0 . 0 0 . 001 TL 90 . 00 PV Pipe: 2 182 . 8 6 . 280 PL 7 . 00 PF 0 . 0 2 2 . 0 0 . 0 27 . 4 0 . 0 1 . 9 140 FTG E PE 0 . 0 3 2 . 0 0 . 0 27 . 4 0. 0 0 . 001 TL 29 . 00 PV Pipe: 3 FIXED PRESSURE LOSS DEVICE 3 2 . 0 0 . 0 27 . 4 0 . 0 5 . 5 psi, 182 . 8 gpm 4 2 . 0 0 . 0 21 . 9 0. 0 Pipe: 4 182 . 8 4 . 260 PL 7 . 00 PF 0. 4 4 2 . 0 0 . 0 21 . 9 0 . 0 4 . 1 120 FTG EGA PE -3. 5 5 10 . 0 0 . 0 18 . 0 0 . 0 0 . 008 TL 49 . 00 PV Pipe 5 182 . 8 3 . 260 PL 144 . 00 PF 5. 7 5 10 . 0 0. 0 18 . 0 0 . 0 7 . 0 120 FIG 4E PE -0 . 9 6 12 . 0 0 . 0 11. 4 0 . 0 0 . 031 TL 184 . 00 PV Pipe : 6 121 . 6 3 . 260 PL 10 . 00 PF 0 . 1 6 12 . 0 0 . 0 11 . 4 0 . 0 4 . 7 120 FTG ---- PE 0. 0 7 12 . 0 0 . 0 11 . 2 0 . 0 0 . 015 TL 10 . 00 PV Pipe: 7 60 . 7 3 . 260 PL 10 . 00 PF 0. 0 7 12 . 0 0 . 0 11 . 2 0 . 0 2 . 3 120 FIG ---- PE 0 . 0 8 12 . 0 0 . 0 11 . 2 0 . 0 0 . 004 TL 10 . 00 PV Pipe: 8 60 . 7 1 . 610 PL 17 . 00 PF 3. 2 , 8 12 . 0 0 . 0 11 . 2 0 . 0 9 . 6 120 FTG T PE 0. 0 9 12 . 0 5 . 6 8 . 0 15. 9 0. 126 TL 25 . 00 PV Pipe: 9 44 . 8 1 . 610 PL 10 . 00 PF 0. 7 9 12 . 0 5 . 6 8 . 0 15. 9 7 . 1 120 FTG ---- PE 0. 0 10 12 . 0 5 . 6 7 . 3 15. 2 0 . 072 TL 10 . 00 PV Pipe: 10 29 . 7 1 . 610 PL 8 . 00 PF 0. 3 10 12 . 0 5 . 6 7 . 3 15 . 2 4 . 7 120 FTG ---- PE 0. 0 11 12 . 0 5 . 6 7 . 1 14 . 9 0 . 034 TL 8 . 00 PV Pipe : 11 14 . 8 1 . 610 PL 8 . 00 PF 0 . 1 11 12 . 0 5 . 6 7 . 1 14 . 9 2 . 3 120 FTG ---- PE 0 . 0 12 12 . 0 5 . 6 7 . 0 14 . 8 0 . 009 TL 8 . 00 PV Pipe : 12 60. 8 1 . 610 PL 17 . 00 PF 3.2 7 12 . 0 0 . 0 11 . 2 0 . 0 9. 6 120 FTG T PE 0 . 0 13 12 . 0 5. 6 8 . 1 15 . 9 0 . 126 TL 25 . 00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/20/2007 E: \SPRINK DESIGN\MB\NE ANIMAL SHELTER 7-19-07 .SDF JOB TITLE : NE ANIMAL SHELTER PIPE TAG Q (GPM) DIA(IN) LENGTH PRESS . END ELEV. NOZ . PT DISC. VEL (FPS) HW (C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe : 13 44 . 9 1 . 610 PL 10 . 00 PF 0 . 7 13 12 . 0 5 . 6 8 . 1 15. 9 7 . 1 120 FTG ---- PE 0 . 0 '14 12 . 0 5 . 6 7 . 4 15 . 2 0 . 072 TL 10 . 00 PV Pipe : 14 29 . 7 1 . 610 PL 8 . 00 PF 0 . 3 14 12 . 0 5 . 6 7 . 4 15 . 2 4 . 7 120 FTG ---- PE 0 . 0 15 12 . 0 5. 6 7 . 1 14 . 9 0 . 034 TL 8 . 00 PV Pipe: 15 14 .8 1 . 610 PL 8 . 00 PF 0 . 1 15 12 . 0 5 . 6 7 . 1 14 . 9 2 . 3 120 FTG ---- PE 0 . 0 16 12 . 0 5. 6 7 . 0 14 . 8 0 . 009 TL 8 . 00 PV Pipe: 16 61 . 2 1 . 610 PL 17 . 00 PF 3 . 2 6 12 . 0 0. 0 11 . 4 0 . 0 9 . 7 120 FTG T PE 0 . 0 17 12 . 0 5 . 6 8 . 2 16. 0 0 . 128 TL 25 . 00 PV Pipe: 17 45 .2 1 . 610 PL 10 . 00 PF 0 . 7 17 12 . 0 5 . 6 8 . 2 16. 0 7 . 1 120 FTG ---- PE 0 . 0 18 12 . 0 5 . 6 7 . 5 15 . 3 0 . 073 TL 10 . 00 PV Pipe : 18 29 . 9 1 . 610 PL 7 . 00 PF 0 . 2 18 12 . 0 5 . 6 7 . 5 15 . 3 4 . 7 120 FTG ---- PE 0 . 0 19 12 . 0 5. 6 7 . 2 15 . 0 0 . 034 TL 7 . 00 PV Pipe: 19 14 . 9 1. 610 PL 10 . 00 PF 0 . 1 19 12 . 0 5 . 6 7 . 2 15 . 0 2 .3 120 FTG E PE 0 . 0 20 12 . 0 5 . 6 7 . 1 14 . 9 0 . 009 TL 14 . 00 PV NOTES : (1) Calculations were performed by the HASS 7 . 8 computer program under license no. 5002007210 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0 . 004 gpm and a maximum imbalance at any node of 0 . 074 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 9 . 7 ft/sec at pipe 16. (4) PIPE FITTINGS TABLE Pipe Table Name : CUSTOM. PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 7/20/2007 E : \SPRINK DESIGN\MB\NE ANIMAL SHELTER 7-19-07 . SDF JOB TITLE : NE ANIMAL SHELTER PAGE: A MATERIAL: S40-TW HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPVly NPTee 1 . 610 4 . 00 8 . 00 2 . 00 9 . 00 6 . 00 1 . 00 10 . 00 10 . 00 8 . 00 3 . 260 10 . 00 20 . 00 7 . 00 22 . 00 14 . 00 1 . 00 18 . 00 18 . 00 20. 00 4 . 260 13 . 00 26 . 00 8 . 00 29. 00 16. 00 3 . 00 26. 00 26. 00 26. 00 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N. . Ell Tee LngEll ChkVly BfyVly GatVly NPTee 6. 280 22 . 00 47 . 00 14 . 00 51 . 00 16 . 00 5. 00 47 . 00 C4 7 O J w H C7 WATER SUPPLY ANALYSIS 100. 0 Static: 80. 00 psi Resid: 75. 00 psi Flow: 1090.0 gpm y LEGEND v 0 Available pressure N 1 79.59 psi @ 282.8 gpm Z 0 0 Required pressure 0 2 27.48 psi @ 282.8 gpm z A. Source Supply Curve H G 80 . 0 _1 B. System Demand Curve 3� A r ro U x H G ro z E y r M P 60.0 to R' H c z � E x S o a S � m U H K E 40. 0 > mr / H ( n z P 2 > z s H r i > v 20. 0 tr H In ti r H C+7 0. 0 B H I 0 'd M m -14.7 � rn 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 7/20/2007 E: \SPRINK DESIGN\MB\NE ANIMAL SHELTER 7-19-07 .SDF JOB TITLE: TIE ANIMAL SHELTER WATER SUPPLY CURVE 84+ I 0 \\\\\\\ * <-75 . 0 psi @ 1090 gpm I Flow Test Point I 70+ i I I 63+ I I I P 56+ R E I S S 49+ U I R I E I 42+ ( I P I S I 1 35+ I I I 28+ X I i i 21+ ---------------------------- I 14+ LEGEND " I X = Required Water Supply 1 27 . 48 psi @ 282. 8 gpm 7+ I 0 = Available Water Supply " I 79. 59 psi @ 282 . 8 gpm " ' I " 0++-+---+----+-----+------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM)