Loading...
1 HIGH ST - BUILDING INSPECTION 1p33 The Commonwealth of Massachusetts sl S y Board of Building Regulations and Standards CITY OF } Massachusetts State Building Code,780 CMR SALEM Revised Mur 2011 Building Permit Application To Construct,Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applie Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcetlyumbers bT"0 l.la Is this an accepted street?yes no Mapum Nber Parcel Number I ( n 1.3 Zoning Information: IA Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(n) "1v I 1.5 Building Setbacks(ft) CA Front Yard Side Yards Rear Yard n. Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: mrj Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system,❑ Check ifyes❑ .,y SECTION 2: PROPERTY OWNERSHIP' N 2.1 Owner'of Record: Eric Olson Salem, MA. 01970 Name(Print) Ci 7..1 1 High St 9c'9 6nz ^03 Wherrymani 1 @gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK=(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units- Other ❑ Specify: Brief Description of Proposed Work 2: } y� AA. of- Co tm SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ I 13 C3 City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ I ❑Paid in Full ❑Outstanding Balance Due: I I I ! I 1 SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) J !1 tM r1� 9�� � toN 1 1K -, -S �Q'('(Y2.�1`() License Number Expiration Date Name of CSL Holder U F_ _ O,f/` ll a� � List CSL Type(see below) U No.and Street 1Type Description Q , _ l X� , I ^ i�� 0\qo Lo U Unrestricted(Buildingsa to 35,000 cu.ft.) City—/Town,State,ZII� "� R Restricted l&2 FamilyDwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances '155)305 ) ,vLQ1J(�t`VU�VIiLLAY I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) V \nt SCxar HIC Registration Number Expiration Date HIC CorwNvwwaut Name No. No.anNa uT `1 '� ' Email address Ci /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........❑ No...........O SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize J)ywn t SD\k,IY to act on my behalf,in all matters relative to work authorized by this building permit application. C�. (24 , 12/29/14 Print Owner's Name(Electronic Signatu ) Date SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print Owner's or Authorized Agent' a(Ele nic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.�ov4 /oca Information on the Construction Supervisor License can be found at www.mass.eov/dps 2. When substantial work is planned,provide the information below: Total Floor area(sq.ft.) (including garage,finished basementlattics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost' CERTIFICATE OF LIABILITY INSURANCE °"'31/20'°°"""' 10/31/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 HNN Ear: ac No: DENVER,CO 80202-5534 E-MAIL Attn:Denver.certrequest@marsh.00m,Fax:212.948.4381 ADDRESS: INSURER(S) AFFORDING COVERAGE NAICO 462738-STND-GAWUE-14-15 INSURER A:Evanston Insurance Company 35378 INSURED Vivint Solar,Inc: INSURER a:Zurich American Insurance Company 16535 Vivinl Solar Developer LLC INSURER e:American Zurich Insurance Company 40142 3301 North Thanksgiving Way INSURER D: Suite 500 Lehi,UT 84043 INSURER E: NSURERF: COVERAGES CERTIFICATE NUMBER: SEA-002368030-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADOLSUSR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE POLICYNUMBEft IMMIDDIYYYYI (MMODYYYY1LIMITS A GENERAL LIABILITY 14PKGWE00274 1110112014 11/0112015 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREMISES'fC,.Tarce1 S 50,000 CLAIMS-MADE OCCUR MED EXP(Any one person) S 5,888 X $5,000 Ded.BI&PD PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 POLICYFX PRO- LOC I I S B AUTOMOBILE LIABILITY - BAP509601500 1110112014 11101/2015 COMBINED ISINGLE LIMIT $ 1,888,888 X ANY AUTO BODILY INJURY(Per person) S ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident) AUMBRELLAU X OCCUR 14EFXWE00088 11101/2014 11/01/2015 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 OED RETENTION$. $ C WORKERS COMPENSATION WC509601300 1110112014 11/01/2015 WC STATU- OTH- AND EMPLOYERS'LIABILITY B ANY PROPRIETORIPARTNER/EXECUTIVE YIN WC,Igr 9601400 11/81/2814 11101/2015 E.L.EACH ACCIDENT $ 1'888'880 OFFICER/MEMBER EXCLUDED? NIA (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,008,080 Use,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A �Erom&Ornissions& 14PKGWE00274 11/01/2014 11101/2015 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Mich ACORD 101,AddINI Remarks Schedule,U more apace Is requlned) The Certificate Holder and others as defined in the written agreement ale included as additional insured when;required by written contract with respect to General Liability.This insurance is primary and non- contributory over any existing insurance and limited M liability arising out of the operations of the named insured and where required by written contract Waiver of submgalion is applicable where required by written contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORRED REPRESENTATIVE of Mandy USA Inc. Kathleen M.Parsloe ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of IndustrialAccidems Office of Investigations = I Congress Street,Suite 100 4 Boston,M4 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/StateiZip:Lehi, UT 84043 Phone #:801-377-9111 Are you an employer?Check the appropriate box: Type of project(required): L E I am a employer with 10 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling - ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' cont insurance.t 9. E] Building addition [No workers' comp. insurance P� required.] 5. Q We are a corporation and its I0.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. (No workers' comp. right of exemption per MGL insurance required.] t c. 152, §1(4),and we have no 12.❑ Roof repairs employees. (No workers' 13.0 Other S018r Installation comp. insurance required.] "Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp,policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic.#:WC 509601300 Expiration Date: 11/1/2015 �/ Job Site Address: t 1�h�� City/State/Zip:��_OP Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided above is true and correct Sipnature: Date? Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1. Board of health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: :„ cr [r rrr cy Uvt wYyc�t raGtctiy Office of Consumer Affairs tnd Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. SCA 1 0 20M.05m Address ❑ Renewal Employment ❑ Lost Card 1�! Massachusetts - Department of Public Safety �f Board of Building Regulations and Standards Construction Supenisor License: CS-046254 . rn JAMESRSHERM� N --- 6 Fox Hollow DrWe _ SAUGUS MA 01406 II s Expiration Commissioner 08/28/2016 I� dt _ I 4031 North 300 lVcsl.Croda.UT 84604 Employer Identification No.: 80-0756438 I VIV11'1t. solar"Phonc(877)414-4129 Fax:(901)765.5758 MassachusemsMCLicense No.: 170848 1 Mail: xuwlar.rlvivinisolur.com , I r�(� 13-malivinpponOt'i AR No.: 41(J 77 RESmENTIAL POWER PURCRASE AGREEMENT This RESIDENTIAL POWER PURCHASE AGREEMENT this"Agrcned Cur o entered into, 'and between VIVINTTrans SOLAR DEVELOPER,LLC,a Delaware limited liability tympany('We","Ua'","Oaf')and the undersigned Cusmmer(s)("Yea",by, as of the Transaction Date set forth below. I Full Name(Fi,. an.�.p e f^ Full Name/era,eco,torp Cuatomer(s): P''non o"^n aria D1. G �" q r 1 I'roorm o.,re. oro 00o Telephone No.: !Q — _ E-Mail: W«e.rrn / !9' rrMJ r z/jl Property Shut Address: Address: City,County,State,Zip: Sn �M A - in D 1.SERVICES IA. DESIGN AND INSTALLATION. Wewill d snu, install,smive and maintain a talon phomvuluic system on Your Property,which will include all l Solar panels,inecnurs.nu9cra.and oder cmnponents(eollecincly-the"sew eni'I as hmhcr doscrihed in the Com nTies-Packet and the Work Order[hat We will phry ids to You hereallo. All material portions of the System,will Ac installed by Our c npk,ycd technicians and electrician.and not subconu:mlorx. With Your car ration. We will til desren, install and en.ineet the System in material compliance with all applicable Imus:(n)complete all required inspections:notl •(iill obtain all required certnicaiiuns and permits. In order In tlesien is System that meets Your needs.Yuu agr r.Ihal We may obtain Your electrical usage history fiam Your electric nnlity(dun"Urilin")and Ynu Shall prouidc Its with copies til'four Utility hills as We may reasonably request. Other than the swdyaonm fe desed1wd in Scoion 1.1 .We will design and in t.11 the Nvnem m nst to Ynu, B. ACTIVATION. You agree to pay Us a one-time activation IT;in the anomrm of S. — We frill interconoeet Ilse SyAenh with lm Utility.and cause the Sysmm m generate energy measured in kilowatt hours (kWh"))(tic "finer�ya ) �Ilatiun of he System generally takes one day and is anticipated m begin and be substantially complete between two(2)and six(6)weeks herea Ter C. OWNERSHIP OF SYSTEM..We shall own the System as Our sole personal pmperty. You will have no property interest in the System. D. OPERATIONS AND MAINTENANCE. We will operate and maintain die System(i)at Our sole soar and expense,(ii)in good condition;and(iii)in material compliance with all applicable laws and permits and the Utility's requirements E. INSURANCE. We carry'commercial general liability insurance,workers'compensation.insurance,andinsurance on the Sysmm1For more information concerning Our insurance,and to m obtain a copy of Ocertifmcam of insurance,please visit: www.yi iry ccordinsurance.' 2.TEI2D1,PRICE,PAYMENTS.AND FINANCI\L DISCLOSURES A. ENERGY PRICE, For all Energy produced by the System,You shall pad Us$0._ per kWh(Ne"Energy Price'),plus applicable lazes. The Energy Price shall increase each year by_two,snit nine-tenths percent( ii V :A 41,,e t eshmam of the System output,measured In kilowatt hours will be Vrovided to You in the Customer Packet. THIS AGREEMENT IS OR THE S.\LE OF ENERGY BY US TO YOU AND NOT FOR THE SALE OFT A SOLAR ENERGY DEV ICE. B. TERM. This Agreement shall beeRective as of the Transaction Date and continue untillinetwentieth(20'')anniversary of the In-Service Date(the Te�. The"1rSe.*e Dare"shall be the first day after all of the following have been achieved: (i)the System has been msralled and is capable of generating Energy,(ii)all permits necessary to operate the System have been obtained,(iii)the System has been interconnected with the Utility,and(iv)all inspections and certificates required under applicable law or by the Utility have been completed or received. C.. PAYMENTS.`,Beginning with the first month following the In-Service Date and throughout the Term,'We will will send You an an invoice reflecting the (charges for Energy produced by the System in the previous month. You shall make monthly ppaayments to Us by automatic paymetit deduction from Your designated checking account or credit card. It is Your responsibility to assure that there are aaegoate funds or adequate credit limit. There-is no financingg W charge associated with this Agreement. For all yaym�r is more than ten(I0)its past due,We may impose a late charge equal to Twenty-Five Ibllars($b) and mteresl at an annual ram of Len percent(10°/),plus appDlicable taxes. if You continue m fail m make any payment within tan(10)days of cr We give You written notice,then We may exercise all remedies avmlable to Us pursuant to Section 13(b). D. RENEWAL Ache end of Ili lenn.You....y clect to fit efoahme wilh fiis Agreement on a.yemdn-year basis (i)cater inn n new Agr=aman widh7 Us and anal this Ass m n,(tai)purchase the Systemat the-end x t the Tam an�camel.this„Aliment(the'PmWa a OPnnn ) or Qh)can el ihlsyi Agreement midhaveIle Svsmm remov xl l no Gust to You V u nlll n•e i I oolify Us In siding c nc mm Your lemon soh(60)days print to theEnd ml The lent. If 1 mi a eta The PurihaSe Oprinn, the Parckuse Opnnn PH”,will he the therl.on tit fair market value of the Svcten based on an mdcpasdent appraiser's valuation ol'timilml,sited photovoltaic systems in four •ographie mum The appraiser's valuation will be provided m)'nu in writing and will,fun binding. 11'N@ rccen'e\'syr garment of[he ISnchase Option rice.costs o�me appraisal.applicable tares.xnd all orMr amounts hien ...vmg and unpaid hereunder.We will wansfer ownership of the System to You at the end of the Perm on in'As Is,Where Is'basis. If You elect to have the Ssstem removed.We will remove the System Iron Your Pn�peri))•within time4y((94 days after the end of the Term. IF YOU DO NOT NOTIFY US OF YOUR EI.ECTION TO CANCEL R1' SF.NUINC A \1'NI'FI-EN NOTICE TO US,THEN THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS UNTIL YOU NOTIFY US IN WRITING OF YOUR ELECTION TO CANCEL AT LEAST SIXTY(60) 1 DAYS PRIOR TO THE END OF THE RENEWAL TERM. E. CREDIT CHECK. in connection with the execution of this Agreement and at any time during the Term,You hereby authorize Us to(i)obtain Your credit rating and report from credit reporting agencies;(ii)to report Your payment performance under this Agreement to credit reporting agencies;and (iii)disclose this act other information to Our affiliates and actual or prospective lenders,financing parties,investors,insurers,and acquirers. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE, YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE(SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3.LIMITED WARRANTY A. ILIMITED-INSTALLAP ION WARRANTY. We provide a workmanship warranty that the System shall be free from material defects in desigof and workmanship under normal oil sting conditions for the Term.•We further warrant that all rooftop penetrations We install shall be w5rertidehI as of the date of,. installation. We dm not provi a any warranty to You with respect m any component of me System. Any manufacturer's warranty issto ad tucin us,not in lieu of,this limited installation warranty. This warranty dues not cover problems resulung hem exposure to harmful materials and chemicals, fire, flood, earthquake,or other sets of god,vandalism,alteration of system by anyone not authorized by Us,or any other cause beyond Our control. B. MANUFACTURERS' WARRANTIES. The System's solar modules carry a minimum manufacturer's warranty of twenty(20 years as follows: ((a))during the first ten(10)yyears of use,the modules'electrical output will not degrade by more than ten percent(10%)from the ogrnalfy led nu1ptat;and (b)dining rhe first twenty(20)years of use,the modules'electrical output will not degrade by mom than twenty percent(20%)o fiam the ongu my rated ourytat. The System's inverters carry a minimum manufacturer's warranty of ten(10)years against defects or component breakdowns. During the Term,We will enforce these warranties to the Pollest extent possible, C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3,WE MAKE NO OTHER WARRANTY TO YOU OR ANY OTHER PERSON, WHETHER EXPRESS, IMPLIED OR ST TORY, AS TO THE MERCHANTABILITY OR FITNESS FOR ANY PURPOSE OF THE EQUIPMENT, INSTALLATION, DESIGN, OPERATION, OR MAINTENANCE OF THE SYSTEM, THE PRODUCHON OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HEREUNDER, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANY BREACH OF ANY WARRANTY IS LIMITED TO REPAIRING THE SYSTEM OR YOUR PROPERTY TO THE EXTENT REQUIRED UNDER THIS AGREEMENT. YOU ACKNOWLEDGE THAT WE ARE RELYING ON THIS _SECTION 3.C.AS A CONDITION AND MATERIAL INDUCEMENT TO ENTER INTO THIS AGREEMENT. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. 4.REMOVAL OF THE SYSTEM Ynu shall not make any Alterations las dcfir al in Section 9I""m the S}stem. If You want to make repairs or improvements to Your Prepeny Ihnt require the temporary remuval'ot the Systym nnhat could intcrfc a with its perforant.cire operation,Yon must(..Ive Us a[Icast shiny 1711)days'pnm wrlltnr notice (a"Grsrnrnvr-Requewud.tihul +nil. 1'so agree that any repair or imprnvcmem to Your Pnnpcny shell not mnenaliy,slid four rrml'whem the System is installed. As cum nnsation list tint temovxl,storage,mal reinstallation ol'tbe System.You agree Io pay to US a fee equal To Four I lmolmd and Ninety-Nine Dnllnrs 154941 hcl!n,i We rcmuve the Systcm. Yon shall be required in pay the 4huWoxo Paymem las definal in Section I i)ilihe System is nal reinstalled within thiny'(30)days of removal. In Ibe even[of un emergency:J76cune the System.You sh:dl comae[ US nnr7wSFatcly. If We are unable to tamely rtxpond.You m:[v tat four own expert gel contrna with a licensed and qualified solar installer to remove the System as necessary m make repairs required by the emergency. You.shall he rsspsnsihle lin any damage it,[he Syeiem That dcstdd Gum actions taken by Your contractor. f S.ARBITRATION OF DISPUTES Most customer concerns can be resolved quick)y and amicably by calling Out customer service department at(877)4044129. If Our customer service department is unable to resolve Your concern,You and We a ce to resolve any Dispute(as def net below)throu¢h binding arbitration or small claims wit instead of courts of geneml Jurisdiction. BF5IGNING BELOW,YOU ACKNOWLEDGE AND AGREE THAT(1)YOU ARE HEREBY WAIVING THE RIGHT TOA TRIAL BY JURY;AND(11)YOU MAY BRING CLAIMS AGAINST US ONLY 1 YOUR INDIVIDUAL CAPACITY,AND NOT ASA PLAINTIFF OR CLASS MBER IN ANY PURPORTED CLASS OR REPRE ,TATIVE PROCEEDING. You and We agree to arbitrate all disputes,claims controversies arising out of or relating to Ggwiu4U. txns sato llm Onnn.11(: sll kieluskumrvcd a... �. Ict .. I ;1i I,. I I i �. OF OUR AFFILIAIES. DIRECTORS, EMPLOYEES. AGENTS, • OR CONTRACTORS FOR ANY SPECIAL, EXEMPLARY, INDIRECT. INCIDENTAL, CONSEOUEN"IIAL OR PUNITIVE -+ DAMAGES(WHETHER 01 NUT THE CLAIM TIIEREFORF IS BASED ON CONTRACT,TORT,DUTY IMPOSED BY LAW OR ._ ill ilii\�, Ali i ri . . ( .,.I 1 e OTHERWISE). IN CONNECTION WITH.ARISING OUT OF.OR I,' , IN ANY WAY RELATED "TO THE TRANSACTIONS - CONTEMPLATED BY THIS AGREEMENT OR ANY ACT OR OMISSION OR EVENT OCCURRING. W CONNECTION THEREWITH. YOU HEREBY WAIVE.,RELEASE.AND AGREE NOT TO SUE UPON ANY SUCH CLAIM FOR ANY SUCH • - - Ia 1. DAMAGES. WHETHER OR NOT ACCRUED AND WHETHER OR NOT KNOWN OR SUSPF,CIED TO EXIST IN YOUR FAVOR. YOU FURTHER AGREE THAT NO CLAIM. LAWSUIT, OR ANY OTHER LEGAL OR ARBITRATION PROCEEDING IN CONNECTION WITH,ARISING OUT OF,OR IN ANY WAY RF.IA"IED TO THIS AGREEMFNT MAY BE .. BROUGHT. COMMENCED OR FILED MORE THAN ONE ((1) YEAR AFTER THE INCIDENT GIVING RISE I O SUCH CLAI:N YOU ACKNOWLEDGE THAT WE ARE RELYING ON THIS SEC AS A CONDITION AND MATERIAI, 11 ! TO F,N I IK INTU THIS AGREEMENT. -•I + 18.1ADI'AI AIE II AITUv 1:• 1{ .v., l P•nnll l iv „ - ,1;11, 'i{, , 1 h 4 'i ua .I I'll_ w, •"1, 27.1 11 Ill l p u<. I' I I.r 1'. . I rill 1 II II.•I,. I I 1, ,.,1 I 1 .',,'. 1,..' ' •. •' I 1111.1.11 1. -11tr) 1 •! •1 L 1. 1 rn ,,. '(lrrrrl i! Prr..rli", Il.n•' .n•• .e..l Li tlm.l I.n,. .1..11.,.. ..r.,•m s, w m II u, , 1 ., I•. : d.ltll hl_❑II II :. 11.1... 1 . .......... whrtuluiIII,' and nnv audion vJ♦ ard. NP^' In/that Keapa OW We will I d I - F\ pa rally Nm fYule mlm rwno (. pt ps pm dcd in I,.d4 Lin. >.n ., ❑aulRl I I.,, Ih r, In. ,.I .IF .. $ntnn21..11 Von wu,e anJ tilmcr rchxx bs`IIm an)Di.pm,minting ra,R an>ing nl h n F,'.c l!,.n. 1.u; h1 1.1 .i•1= \. ., rn 1 +n out ot;un unt 28. li:,�>I., .n' .,111..II nr+_•,ndl. ' that 'i•.a, N).i'RI.\i [it IN l\II 01114U1I \t/!111'- THIS n'•L mmrl.. n " A.1 'o-o.and Ihl. r.. 51 .x1.111 .„.1 1rid, 1! "P 3ED ON tis ..arn. ” ,.....:.1.. p,l r Ih. h."', 4.ranh Thad P,,,. J.u.:. INFORMATION IN YOUR CREDIT REPORT INDICATING .".nrlyd :1,.., 1.11..n cngd,.. .,:, •r s.m.,:1. 1I \"m P,q,,,, THAT YOU MEET CERTAIN CRITERIA. THIS OFFER IS NOT InJ .,,,]I'.,.nr ."I .......1,!, 'I"d to III,•I,rr., n..i,aol;: GUARANTEED IF YOU DO NOT MEET OUR CRITERIA. IF YOU DO NOT WANT TO RECEIVE PRESCREENED OFFERS i9.\I FiRf-f41.\I IU\. %,d. ant,. .. ,I, ..11 1 .,,rn.l i;.r.v.. OF CREDIT FROM US AND OTHER COMPANIES,CALL THE InIII .Ip II.unn .n all, Ialll,I. I- 1'n.nrlr \,•", snlhnr.n m CONSUMER REPORTING AGENCIES TOLL-FREE, (888) 567- 1"p, n,nw ..1.h I. 1 wIJ In.urAl", .Inp..n, and 1.... ....l:c 8688;OR WRITE: EXPERLAN OPT OUT,P.O.BOX 919 ALLEN, Jdcr:! I .mdl•-•1 .,1, •F1,1, .Iwn. !++( i,R1 i I.I \r.l It l TX 75013; TRANSIINION NAME REMOVAL OPTION, P.O. 11•1 R 1`.,I It\\I I i 11t.Ill\%'i .,I fi ll•.'t! it \v BOX 505 WOODLYN. PA 19094; EOUIFAX OPTIONS, P.O. 20.AMENDMENTS AND WAIVERS Thn Aglcemcm may only he amenMA nr BOX 740123 ATLANTA,GA 30374-0123. 1 1 ' I ! t �. II1 1 / (i)any aspect of the relationship between You and Us,whether based in contract,Inn,statmc or any other legal theory;(ii)this.Agreement or any outer agreement concerning the subject matter hereof: (iii) any breach, default, or termination of this Aff,�,rcement; and (iv)tile interpretation,validity,orenforecabiIRy of this Agreement.including the determination ofthe scope or applicability o(this Section 5(each,a 'Dispute'). Prior to commencing arbil ration,a ppuny.,lost first set, a wriucn"Notice of Dispu4'vie ecru tied mail to the o—if r parryy. The Notice of Dispute must describe the nature and iasis for the Dispute and the relic]sought. 11 You and We are unable to resolve tic Dispute ,illion thirty (10) days, then either puny may commence arbitration. The arbitration shall be administered by JAMS pursuant in its Streamliner(Arbitration Rules and Procedures bo-olluhh1 nc hitt /hvww.Jamsadccom/rules-streamlined-arbitration.the"JAMS Rules'')and under the rules set fourth in this Agreement. The arbitrator shall be hrnmd by the terns of this Agreement. No matter the circumstances.the arbilmmr shall not awn rd pull hive.specia1. exemplary, indirect.or consequential damages to either party. If You initiate arbitration, You slwll be responsible m pay $250. All attorneys' lees. travel expenses,and other crisis of the arbitmtirin shall he borne by You and Us in accordance with the JAMS Rules and applicab(e law, The arbitration shall he conducted at:t mutually agreeable location near Your Property. Judumem rim an arbitration award may be entered in an`{ court ofeompctent jurisdiction. Nothing in this Section 5 shall preclude You or We from seeking provisional remedies in aid of arbitration Irom a court tit competent jurisdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES'PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION TO NEUTRAL ARBITRATION. �eerns tenet,: i IIWE AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,(ii)the Additional Terms and Conditions,(iii)the Customer Packet.and(iv)the Work Order. These documents are expressly incorporated into this Agreement and apply to the relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Ageement,that We have signed the Agreement,and that You have read and received a legible copy of every document that We taave signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled In copy of this Agreement,signed by both You and Us,before any work may be started. (E(. YOU MAY CANCEL THIS TRANSACTION AT ANYTIME OR(P[tR)IOR TO THE LATER OF: ((1)MIDNIGHT OF THE THIRD ME)NOTICE OF CANCELSINESS DAY LATIION BELOW FOTRANSACTION R AN EXPLANATION OF THIS RIGTHE START OF INSTAL T ALLA'I'ION OF THE SYSTEM. SEE VIVE4T SOLAR DEVELOPER CUSTOMER(S): a Printed Nauta Ck 1') Ce f G ` Printed Name: Title: S(1 ��yT// By; / Printed Name: Transaction Date: jiJ FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS. CONTACT THE MANSACIIUSE"IIS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAYA,SUITE 5170. HOSTON.MA 02114 (617)973-8700 OR 888-253-3757. -. x---------------------------_------_-------_- NOTICE OF CANCELLATION Transaction Date: AR No.: YOU MAY'CANCEL THIS TRANSACTION,WITHOUT ANY PENALTY OR OBLIGATION WITHIN THREEI3)BUSINESS DAYS OF THE ABOVE DATE, OR (IF LATER) UNTIL THE START OF-INSTALLAT16N OF THE SYS M. IF YOU CANCEL,ANY PROPERTY TRADED IN,ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (l0 BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THISt CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY(20 DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION,YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO,THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOLDEVELOPER,LLC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO THE LATER OF: (1)MIDNIGHT OF THE THIRD(33 BUSINESS DAY AFTER THF.TRANSACTION DATE,OR(11)THE EM. START OF INSTALLATION OF THE SYST1 N RE Y CANCEL THIS TRANSACTION: Date: Customer's Signature: i ' ADDI'PIONAL'FERMS AND CONDITIONS I Ia I'kl .r♦I s tial. I\rr 11 ,F4\vll� . 4 lir L., r r. S. It 11 et At I, 1 I\, I H Nce rri If 111 I 1 rmd( 1 s k "Itua,mcridjusinnI 1 ur pgYm nts 1 ax I on c'r"t d n vu data Our\ nlra cors 'r ey rets_Fmr.mlrrcnml anNo i[w tx the Ltilm iu n w Your of the per n1 I ch n ♦ 11 the raciere- perabi f a>r a:an reel dub I r_penY nJ I 5 1 g n thl t tli m 11(11 dayy..ally WIr y,,,You You failure h r ret n h le broadband m •1 I v I n nti W ...m n u th 1 lu I p' Je ael u s ( )Your Iw kruVUY nwhcn<y may charge You no,the Sburdowon PuYYn I. (h)(a�� Ipp I �axes. II the Seiko,a I nJnussiun til Your mahJ ty m pay Yaw debt as they mature.or(e)Your Proucrityy dama,W rtelloriJh i conn Il ud atlyn �Ier�isaat raccident Ixcrm.. ssb 1u fmiosurc pnmeNi`g (h) enurlr•s hu Guamr,�m De fault. it (u¢6 a Cu u!p E I 1 d b'Our .1 rant W 'III pnmptl'rcpa r ant a Cnsl n "can ca It xanx. We ay rcra any nT th�o7lowin�,rcmalas' rtpi J d B J 1 n n t II SY t ;: t ger m t 1 ,t N ohm �)Per s do 4Ercemeut ant rAmand\o paY the Ucfaul[1'aynlenL Pr)Ienvc dm cont 1 nn If th 1Y'' i.d m. d le 1 uY 1 by La.0 Ip F' n n 1 i rN he vrm n PI Ynnr 1'rupm�y M1w July\nu att�se to nM use of the Encrn•a Our lou an e. Nt. ml ,al Uur option 1 I pair mol 1 swn drc SYsn n nr,xM pr utast, hl It ay Fe redna4nl and se1J at(h(r elethn+.(n)Jrsaonnm ur thke rvurking 1'wrJilion: or iii)wrmiqula this Acrmm_ml d az 1'uur Nsonn,eller Back the System ar pemmneJ Fy Pplicablc law;(n)pleat x Len on Yovr pruperiY; conery the System in its Then-cslrtinp condition, .4s Ix.,,'bare L.".ro You for no (vl cn¢unc a mrllmtivu agrncy w collect paynwnts from Yuua rNon lburdefault aJdiwrrwl cansiJundinn rn nmtwe the yuan from four Pmpem' (c)Ui"Aa,e4y, a m chat,rcgrrlrng aLxnems:?red/or/vii)eacreise an>olhn rtv v avaiNble to Us m of Srvsmin. We may cuua•the Stsmm Ilr lir disnmis vcd Lnan the Ulilny'I IaaGues 11 (his Agrmmam nr Pa. apphcahlc law. (d Sdicr I)efaull. .4"SrOec Osfaulf'.,hall t IeY trWW r h Jisctmn u(n or We arc r gait xl[ JI s r unJtr apPlnaF1,boy. -wan ir xawnnee til nm al Nc lollawma jIS(Sin-I'a'Ilurc to per1olm any of On, 9. YRUR DUTIES. t )Ls 5lith bsi 1 eh 11 s tl E I r ryldennal malcnal M„minus anter Ihlx Agrcrllwm tml Ilw Rpa of srrch Ierlurc rally 2ral pvmtrsas only ant uta Iw heat g a.wmun'nS Wld._91 all li alts {'. than ensure rlh n[luny f illZ dvyv all You give Us x'n[url nlxme tit awh fuilurc or(it)flat dr:n the 1'refwny remains grit<onntc,N hr t c Ulilily. Ih)punrihand Internet bunknlple .taw vent,m admiesron of Dur inability m pay Om'deW a they andood. ('onnecSion. 1'ou moa Prm'Wa the System rvilh eaminunus icecTs to a InTnnloning (dl Ite coli- 1'rI "Icr�llfaule If a Seller Ihfault occurs ant is dmtimmtg,N. imemct ivnneninn u'IW one wire)Ethernet pan and stullJak ckrmcul outlet at Your may: t)tenni',a I "'a Agnelriem ant requea removal ref'[he Sys0.•m (tutu Yuur rest If You f d kr rmlmmm hvadhand int vm'I ur cicnrieal eonne.von by a peIiN of Pay Paul read,.'fill eaupt as pmvWN Mluw,csrresre:my mha rsmaly nv:ulaMrtu ,line,We may chars¢You the Shutdown Pnyment. (c)5 stem Allemlw,r. Yw shall Ymr in lhrs Awcrnrent At under applicahle law. NmwiJsaamlin,the fureauing You not'iryPlmr, •pais ,theorise modil a ry c mnnrnlp I c 'ywem collectively will hove nn right m elnirn Jamsges as a rcsuh of Ne lerminmiun of this Ag nrnl. "A4 linni'1:and(tli)lake mrY action I wt andel+mJ of rmryl r anY rmnty niatinc enccN f r fat Ibc acwal costs h remove the Systwq II We fail m remove l e Syxem m the Sysle, n Ybu will Iw rapQrla �c Iix any Jamaec to the System that is cauad al "on'Y.wr i'nryln,y pursmnt to S�mm IJ;and(y)any damagex m Yow Propmry ry lime by You',or Ynur guest, ncitees etwhacnrrs.m ugrnu. (dl Prolrcnt. uranin, from (ha remm•I', of a rslem by Lis of Ou cavuactor. (el Drfash Ilcmtions. You shall ti)Inco all tines an Sour Pnynrrv,col mswll sw toms un P tx II shrs Ag'mmmr is kmvihalxd fm any reason,dher Ilan pwssmntt a ntirl, unit late mh.•r rcawnab c snips to cnsurc that shadin,of the System is 7o No,N I'ancriwirnt S liyp m a Seller fxlaulq Ynn will pay w Us the DcfeuO r xxc than un dot (rare, III Dow an (iii nrximain.in acrd wndnual nnJ rcuulr. Pennant. the"DefaW+�J'mesu shall hr an anwunt eytwl m Sevm Dollars lS7)per wlIr, t. .. • - \V, IJ. Il call\\Iib\ t.l..: 1 .I ♦ 1 1 Yi V 1.a. IIIit:�, I, A t 1 r. ItA .. .r :r 1 I r t I Mhi• 11 r r Ic U\Il til Ill Ilei\a♦ 1.' GI ' I. •I i. 1r / I n .. 1. e. Art A. is t / , 51 ,d hit .I A. it 'a. .n. f. .(r, ...n it in. tliA It 11a IIt 1\I Inn o, n �d x ( 'd •.P. r. i s a 1-1 .1, 1•, 1 •\nnr;,,nn PaA..../Ir r 1 1 ..i .Ino s1 d..f .Irr . 4v "I. ,1 x.hn .d a "i.,"r(. nca V 'at dma - Y and W that all mount' pay bk by ,uu the Pe Iml f Nc'doodueen Shall be Ino I(4 un the tiryt yarr R Ih ImS 'ice bele d r shall Iw P?Y'IFie n all c'mrt i lad II Your h Irs and est it P pl as Date.on ea nalad levels sf praluniml'and 18)ofpr the fico year afler,he InSeru'ice ,tiro imH by the•Notre orCon,ellat on,\mr hush,w'okc.11 nehls Y ou my hme to Uam, "c nn acetal npe anon of she S>'sum dunng the samv pcnod m the promue Jeal ur cancel Ihn Apr,cmcn,,In rcvnke acsrrpplance til dre Syyaem, mgrznit year. Ita shuldvwnp ouanlm ticeunn<,x III lS:ommues for one lrumlreJ 'nnrity interest in the vslcm. Ic1 yinnt nn UM1L•vli,m Iaa..[[�Inrr WE DV NOT arM eighty IlRfl)Jays or IunE r. ay n Ow !r Jiwrniw. n mmaze this W'ARHANT OIt GUARANTEE 71l�ATTOUNTSSF IiNF:L jTPRODIICED BY Aerzmen[and rreWyuire Youmpay lhr llefaah Pavnlan. 1'I IL S,SI-EM POR ANY HAIM OR ANI'COSI SAYINGS We are nut a Pit lily IG FORCE MAJ PI1, If Yuri ret WI at. In perfamm any uflhe ohligvtinns w public It ...ary,anti do not Protonic any obligation'of a utility o public + scntca ra pl Y t rply Ynur energy reg r t' ",xc tut subj,t I mI, ;A ;t. I. V rev e 'by F+ unana�m thontles Dunn,the Tann YoIL u der. ad Ihm Y Y 1. 'T Millard ort clecuct than the Sydnor may genemm It 1'. n,N s su♦�i I'. 1 .', lity,n t ), °. Millard entry} tiller You shall be solely na pimvble to obtain rich energy from the �'I ,+ e r n t r t 'o rr L'IililyN Ynllf CnaL •I I.. •. r.. .. .r. :.n ,..r("..:a ...rel ' IL UUII k\lill'Irt Nell al 1. v rvt-1 ,.rep r.r.a. u . - 1 ry r . i ._ l . a wrr - o r. I,• 1 .1. + rn , "r, n '.:..n a ♦ e : r.r r l ., rr, '.a.1141. I I .. 'i ,. .• r,l .. r r .. , r 1.•.. r.., In .., ... d r •1 „ I ,I. n 1'1.111111 a1 01111 R111tIV 1, �ar 4 m ��to " NOTWITIISTANDING ANY BREACH OF THIS AGREEMENT, ,rri i'1" „ ' rri ANY FAILURE OF THE SYSTEM,OR ANY NEGLIGENT ACT THAT CAUSED ANY INJURY OR LOSS (WHETHER �I r. keel.\\n'`I .c ni\\,f1 n t. -1 PROPERTY DAMAGE. PERSONAL INJURY OR DEATH) TO .I ANYONE, WE AND YOU AGREE THAT, UNLESS SUCH INJURY OR LOSS WAS CAUSED BY A PARTY'S GROSS 1 NEGLIGENCE, FRAUD OR WILLFUL INJURY. SUCH �l PARTY'S IJA9ILITY' AkISING OUT OF OR RELATING TO r,.r 1 o/,,r. r THIS AGREEMENT SHALL IN NO EVENT EXCEED THE � DEFAULT PAYMENT. YOU AND WE AGREE THAT THIS it I"' " I AMOUNT IS A FAIR REPRESENTATION OF THE DAMAGES I 1 THAT YOU OR WE EXPECT TO INCUR IN THE CASE OF ANY 1 .'.I t 1 INJURY OR LOSS HEREUNDER. NO CLAIM SHALL BE MADE BY YOU AGA( ' IIS OR ANY 1 :I munii solar 3301 North Thanksgiving Way,Suite 500 Structural Group Lehi,UT 84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scott.WysslingcZla vivintsolar com December 17, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Olson Residence 1 High Avenue, Salem MA S-4086390 2.295 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of assumed 2 x 6 dimensional lumber at 16" on center. The attic space is finished and photos indicate that there was no access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCEISEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 15 and 45 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure 'B", Zone 2 per (ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint. solar I i I lil Page 2 of 2 B. Loading Criteria 10 PSF= Dead Load roofing/framing 40 PSF=Live Load (ground snow load) 5 PSF=Dead Load solar oanels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2', is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. ery truly yours, tH ofd O o� E CyG Scott E.Wy ling, civi 50 MA License No. 9p�, FGiSTEP� FSSIONAL vivint. solar i. I "✓ U r C � N JUNCTION BOX ATTACHED T 75 OF 1^PVC CONDUIT d o m FROM JUNCTION BOX TO ELEC PANEL U)a ARRAY USING ECO HARDWARE TO ��o KEEP JUNCTION BOX OFF ROOF N wx Ez C D NO 0 6 M O 7 PV SYSTEM SIZE: — _ - 2.295 kW DC L� I 0 9)Tnna Solar TSM-255 PAC 5.18 MODULES WITH A En00ase M2154I0-21_L-S2x-ZC MICRO-INVERTER o MOUNTED ON THE BACK OF EACH MODULE •O a I I p $ o 0 VI R' U I - I > > Z W U d' R' N Z m W a _ I I z z SHEET NAME: I w Z PVINTERCONNECTION POINT, LOCKABLE DISCONNECT SWITCH, ANSI METER LOCATION, W d 8 UTILITY METER LOCATION ____ ____ ___ SHEET NUMBER: 1 High Ave, Salem MA 01970 PV SYSTEM SITE PLAN o SCALE: 3/32"= V-0" > d I � m m H N AA0 SOL o y�0 3 E ° Sn No m� NH um mi m0 a MOO 3 4 N (.�n z O 0 m N Co D < r Cj) m -< w cq m II � m o Xon O 0, n 0 N T R r D Z Ci DI INSTALLER:VIVINT UMqe�SOLAR 0 Olson Residence P\/ 2 0 m y ROOF 7 y MA LICENSE'MAHIC 170948 4tZ9 �S�"a�'(• solar High Ave V p PLAN DRAWN BY:CRS AR 4096390 Last Motlifievtl:11J16/2014u UTILITY ACCOUNT UMBER:00641-74009 CLAMP MOUNTING SEALING U ,PV3.0 DETAIL WASHER LOWER SUPPORT .N Qom �N/m-Z LLS El vz N0 PV MODULES, TYP. MOUNT "` " °' CO do _ OF COMP SHINGLE ROOF, FLASHING y F _ PARALLEL TO ROOF PLANE / 2 1/2" MIN O 5/16"O z 4 1/2"MINIMUM L PV ARRAY TYP. ELEVATION STEEL LAG SCREWS NOT TO SCALE TORQUE=13±2 ft-lbs O CLAMP ATTACHMENT to NOT TO SCALE a •v CLAMP+ ATTACHMENT CANTELEVER U4 OR LESS or= f COUPLING L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT m COMPATIBLE LETTER FOR MAX ALLOWABLE r 0 MODULE CLAMP SPACING. e cm PERMITTED COUPLINGCLAMP+ CLAMP 5 m a e -- MENT SPAC NG CLAMP ATTAC i m COUPLING PHOTOVOLTAIC MODULE U R R z W W Z m W , n w ¢ <3< Z z f p SHEET NAME: L=PORTRAITV) CLAMP SPACINGt7 Z O g Q O LU ECO 2 O COMPATIBLE SHEET L=LANDSCAPE MODULE PV SYSTEM MOUNTING DETAIL NUMBER: CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 NOT TO SCALE D> f Inverter Ratings(Guide Section 4) 0 Inverter Matureaeei Enpluse M31 56o-2U_ 3S2 c Conduit and Conductor Schedule MODULE DETAIL Max DCVALWtina 41Volb TW oe.cnptm winders. p eoneuuTypa ....dim Max Pewir®40-C Sts Wade t anpx.mendes ...'mrsi U. cop NtA.rm.Ar ca Nomica nal AC vo-.a 340Vs. t flsneressarnd(eGeJGem enWG - rm xlR.ems Ar Ca Trina Solar TSM-255 PA05.18 Max AC caner, 0.9Amps mnwG we A a-,. SOLAR MODULE Max Dope pairs 30 Amps Txw"� Max Number at PanelMCiwit ,] MNM3�GnuM aPWG t PVc p'.1' ca ] MWN3 BPWG a PVG a-1' Ca NOTES FOR INVERTER CIRCUITS(Guide Section 8 and 9): as-dm.ne 9AwG we a-t' mw wwx t m 1.)IF UTILITY REQUIRES AVISIBLE-BREAK SWITCH,GOES THIS PV Module Ratings @ STC(Guide Section 5) N w$M Emphasis M215­60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? N z MICRO-INVERTER AT - YES NO XNA Madel MakWMadbl Trina Solar TSM-255 PA05.18 L.L1 u~ Max Power-Point Came(imp) 8.36 Amps z EACH ,ATTACHED 2.)IF GENERATION METER REQUIRED,DOES THIS METER Mex Power-Point Vadage(Vmp) 30.5 VMta C: V,0 WITH ECO DOHA HARDWARE SOCKET MEET THE REQUIREMENTS? Open,imuit Voltage Woc) 37.7 Volta U YES NO XNA Shod-Circuit Current(Isc) 0.92 Ampa U) Q 3)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Series Fuse(01 15 Amps F BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STC(Press) 255 Wells M ICROINVERTER CON NECTION RATING AT DISCONNECT. Maaimum 0(UL)System Voltage 1000(IECy60O j TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature Coaiccbnt -0.32 %PC ^ TO INVERTER OCPD AMPERE RATING(Sea Guide Section 9) V 5.)TOTAL OF 1 INVERTER OCPO(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix D): PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1)Lowest expected ambient temperature based on ASHRAE minimum mean extreme NEC 690,64(8)(2)(a)? RYES NO dry bulb temperature for ASHRAE ideation most similar to installation locadon: .19-C #6 BARE CU GROUND 11710 (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambientemparalurs based on ASHRAE highest monta 2%dry bulb temperature fair ASHRAE location most similar to installation Mcation: 39-C O -' Sign for inverter OCPD and AC Disconnect: 3)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47-C in the -- United States(Palm Springs,CA is 44.1'C).For less than 9 comereca"Ing conductors Solar PV System AC Point of Connection In roof-mounted sunlit conduit at least 0.5'above Leaf and using the outdoor design AC Output Cumrt B.10000D Amps temperature of 47-C or less(all of United Stales). Nominal AC VaOage 240 Volts a)12 AWG,90-C conductors are generally acceptable for modules with Ise of 7.68 Amps or Was when protected by a 12-Amp or smaller fuse. _ — - THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) b.)10 AWG.90-C conductors are generally acceptable for modules Win Ise of 9.6 Amps a or Was when protectedb a 1 5-Amp or smaller fuss. is NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR as ca ENVOY BOX $ a' Iz neo g m o y N f RWP HWI = yam POINT OF DELIVERY w `of'. AND INTERCONNECTION ed Le z as \y0P0 SIEMENS ¢ a U \O 6 60AI240V z -P0 ik�' RR) MURRAY UNFUSED NEMA3 M Z Z E O\\x. <" COMBINER LNF222R OR PV CIRCUIT 1: 9 MODULES/PARALLEL 'N.`fx FL PANEL 125A/240V SREC/ANSI EQUIVALENT SHEET Oq\0P! LW004NR METER NAME: \O OR EQUIVALENT EXISTING It 02 p ? 100 24ow100A w 1 \ LOAD-CENTER J E 1.0 \\ ,5A M A Q . . . s A o SHEET __ ____ __ A ______ _ 5;I—S-1EI_E/I_0=E NUMBERMILBANKJUNCTION BO% z \\ 3 1ODA OR 'KNIFE'A/C 3WITH IRREVERSIBLE \ EQUIVALENDISCONNECTNEC 2014 Compliant GROUNDSPLICE E 1.0 \ E 1.0 U5934-XL-BIE 1.0 LU � o U THESE ROOF SECTIONS WERE `$ NOT SURVEYED N nK dam LLi Ez —_ C m p r%1 O p Q O 1 MODULES AT 1099 SUN HOURS P L .0 V/ OMP.SHINGLE •e ? T MODULES AT 1119 SUN HOURS ANCELED ROOF SECTION BELOW MINIMUM g a y _ REQUIREMENTS.IS MODULES p 'A U UNABLE TO FIT THE REQUIRED MINIMUM " AT 584 SUN HOURS) � W - NUMBER OF MODULES ON THIS SECTION > 2 U ' Z uJ R R' N 1 q' W W 2 m J .1Z r D 3 w w ¢ Z Z E o SHEET :a NAME: Z UJ0 W J SHEET SOLAR ACCESS CONSTRAINT NUMBER: O ' V a R Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Eric Olson Project Address: 1 High Ave,Salem MA A.System Description: The array consists of a 2.295 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(9) 255-watt modules and(9)215-watt micro-inverters,mounted on the back of each PV module.The array includes(1)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) �I Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12-F) C.Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Eeolibrium Solar b.Product Name: Etorail c.Total Weight of PV Modules and mounting hardware: 423 lbs - d.Total number of attachment points: 37 e.Weight per attachment point: 11.43 lbs f Maximum spacing between attachment points: ` See attached engineering talcs g.Total surface area of PV array: - 158.49 square feet h.Array pounds per square foot: 2.66 lbs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (7)modules,(31)attachments 10.61 pounds -Roof section 2: (2)modules,(6)attachments 15.66 pounds per square foot vivint. solar I ' I I 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 255-PA05.18 9 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 voles Imp-rated current at maximum power - 8.36 amps Ise-rate short circuit current - 8.92 amps B.Inverter (UL 1741 listed) Qty Enphase M215-60-2]j.-S22 9 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters - Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 1 PV circuit 1 - 9 modules/inverters (15)amp breaker 2011 NEC Article 705.60(B) vivint. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 8.1 amps Continuous current adjustment factor 125% 2011 NEC Article 705.6003) PV circuit continuouscurrent rating 10.125 amps 2.Overcurrent protection device rating PV circuit continuous current rating 10.125 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amo AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed I"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(!4) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Article 705.6001) Adjusted PV circuit continuous current 14.2 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 3 conductors Conduit fill derate factor 100% 2011 NEC Article 705.60(8) Final Adjusted PV circuit continuous current 14.2 amps Total derated ampacity for PV circuit 14.2 amps Conductors(tag2 on 1-line)must be rated for a minimum of 14.2 amps THWN-2(90'C)#18AWG conductor is rated for 14 amps (Use#18AWG or larger) 2011 NEC Article 705.60(8) 4.Voltage drop(keep below 3%total) 2 pans 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Ntlrco-inverter voltage drop: 0.05% The largest number of micro-inverters in a row in the entire array is 4 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.05%. 2.AC conductor voltage drop: =I x R x D (-240 x 100 to convert to percent) _(Nominal current of largest circuit)x(Resistance of#18AWG copper)x(Total wire run) _ (Circuit 1 nominal current is 8.1 amps)x(0.0080852)x(150 -(240 volts)x(100) 4.09% Total system voltage drop: 4.14% Vmnt. S0l2" EcolibriumSolar r Customer Info Name: Email: Phone: Project Info Identifier: 18575 Street Address Line 1: 1 High Ave Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-255 PA05.18 Module Quantity: 9 Array Size(DC watts): 2.295 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 44.8 lbs Module Length: 65.5 in Module Width: 39.625 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load-Lateral: 288 Ibf EcoX Design Load - Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load- Downslope: 353 Ibf EcoX Design Load- Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-Ib Module Design Moment—Downward: 3655 in-Ib Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 I EcolibriumSolar Planb Calculations (ASCE 7-05): 2 Roof Shape: Hip Edge and Corner Dimension: 3.4 ft Roof Type: Composition Shingle Stagger Attachments: Yes Average Roof Height: 35.0 ft Include Snow Guards: No Least Horizontal Dimension: 34.0 ft Roof Slope: 45.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.46 0.46 0.46 Roof Snow Load 15.5 15.5 15.5 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift N/A N/A N/A psf Net Design Wind Pressure Downforce N/A N/A N/A psf Adjustment Factor for Height and Exposure Category N/A N/A N/A Design Wind Pressure Uplift -19.5 -23.5 -23.5 psf Design Wind Pressure Downforce 18.0 18.0 18.0 psf Aso Load Combinations Description Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 15.5 15.5 15.5 psf Downslope: Load Combination 3 9.5 9.5 9.5 psf Down:Load Combination 3 9.5 9.5 9.5 psf Down:Load Combination 5 19.7 19.7 19.7 psf Down:Load Combination 6a 21.0 21.0 21.0 psf Up: Load Combination 7 -18.5 -22.4 -22.4 psf Down Max 21.0 21.0 21.0 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 71.1 68.8 68.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 23.7 22.9 22.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 51.6 51.6 51.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.2 17.2 17.2 in I I I I I EcolibriumSolar Layout Skirt e Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with Q Bonding Jumper maximum allowable overhang. f EcolibriumSolar Plane Calculations (ASCE 7-05): 1 Roof Shape: Hip Edge and Corner Dimension: 3.4 ft Roof Type: Composition Shingle Stagger Attachments: Yes Average Roof Height: 35.0 ft Include Snow Guards: No Least Horizontal Dimension: 34.0 ft Roof Slope: 15.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.0 1.0 1.0 Roof Snow Load 33.6 33.6 33.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.05 1.05 1.05 Design Wind Pressure Uplift -16.8 -27.7 -41.6 psf Design Wind Pressure Downforce - 16.0 16.0 16.0 psf !, ASD Load Combinations Description Interior Edge Corner Unit �I Dead Load 2.5 2.5 2.5 psf Snow Load 33.6 33.6 33.6 psf Downslope: Load Combination 3 9.0 9.0 9.0 psf Down:Load Combination 3 33.8 33.8 33.8 psf Down: Load Combination 5 18.4 18.4 18.4 psf Down: Load Combination 6a 37.9 37.9 37.9 psf Up: Load Combination 7 -15.4 -26.3 A0.1 psf Down Max 37.9 37.9 37.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 47.3 47.3 47.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.8 15.8 15.8 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 28.6 28.6 28.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 16.0 16.0 16.0 in Max Cantilever from Attachment to Perimeter of PV Array 9.5 9.5 9.5 in EcolibriumSolar Layout • 3w im L_I D - Skirt e Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with Q Bonding Jumper maximum allowable overhang. EcolibriumSolar Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 403 lbs Weight of Mounting System: 74 lbs Total System Weight: 477 lbs Total Array Area: 162 ft2 Distributed Weight: 2.94 psf Number of Attachments: 37 Weight per Attachment Point: 13 lbs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 37 ECO-001_102 EcoX Coupling Assembly 6 ECO-001_105B EcoX Landscape Skirt Kit 2 ECO-001-105A EcoX Portrait Skirt Kit 3 ECO-001_103 EcoX Composition Attachment Kit 37 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly 2 ECO-001_106 EcoX Bonding Jumper Assembly 6 ECO-001_104 EcoX Inverter Bracket Assembly 9 ECO-001_338 EcoX Connector Bracket 9 f ti I j�l