Loading...
13 HANCOCK ST - BPA - SOLAR T�— � �I-- � 552. u< ssi�st �22.z. � The Commonwealth of Massachusetts � � °� Board of Building Regulations and Standards SALEM Massachusetts State Building Code, 780 CMR Revised Mar 2011 • , Building Permit Application To Construct,Repair,Renovate Or Demolish a One- or Two-Family Dwelling This Section For Otlicial Use Only Building Permit Number: Date pplied: � � Building O�cial(Pnnt Nama) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers � - 13 Hancock Street gg 0240 l.la I5[his an accepted stree[?yes X .no Map Number Parcel Number � � 1.3 Zoning Informallon: 1.4 Proper[y Dimensions: R2 residence-no change � Zoning District �� Proposed Use � Lot Area(sq R) ' Frontage(ft) 1.5 Building Setbacks(ft) n/a Front Yard Sidc Yards Reaz Yard � Required Provided Required Provided Required � Provided 1.6 Water Supply:(M.G.L c.4Q§54)� 1.7 Flood Zone Informatlon: 1.8 Sewage Disposal Systero: Public❑ Private❑ Zone: _ Outside Flood Zone? � Check if yesO Municipal� On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP� 2.1 Owner of Record: I � John Hayes Salem,MA 01970 Name(Print) � City,S[ate,ZIP 13 Hancock Street 978-979-9520 .jthayes1212@gmail.com I No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORKZ(check all that apply) New Construction O Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ , Demolition ❑ Accessory Bldg.❑ Number of Units Other Lj3 Specify: solar . Brief Descrip[ion of Proposed WorkZ: Installation of a 7kW roof mounted solar array using 28 Canadian Solar CS6P-250P modules,28 Enphase M215-60-2LL-S22 micro inverters,and all associated electrical work. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: p}'}j¢jal Use Only Labot and Materials • 1.Building $ 6,000 � �� Building Permit Fee: $ . Indica[e how fee is determined: ❑5[andard City/Town Application Fee 2.Electrical $ 25,000 ❑Total Project Cost�(Item 6)x multiplier x 3.Plumbing $ � 2. Other Fees: $ 4.Mechanical (HVAC) $ List: , 5.Mecha�ical (Fire $ � Su ression Total All Fees:$ � 6.Total Project Cost: $ 31,000 Check No. Check Amount: Cash Amount ❑Paid in Full ❑Outstanding Balance Due: Q� PdL� �{�ZS SECTION 5: CONSTRUCTION SERVICES . 5.1 Construction Supervisor License(CSL) 102054 10/6/1� MichaelRotondo LicenseNumber ExpirationDate Name of CSL Holder 61 Gellette Road List CSL Type(see below) No.and Street Type Description Fai�haven, MA 02719 U UnresMcted Buildin s u to 35,000 cu.ft. R Restricted I&2 Famil Dwellin City/Town�ate,ZIP M Mason �� , RC Roofin Coverin ' WS WindowandSidin SF Solid Fuel Buming Appliances 401-215-7056 michael.rotondo@rgsenergy.com I Insulation � Tele hone Email address D Demoli[ion 5.2 Registered Home Improvement Contrector(HIC) 162709 Alteris Renewables dba RGS Energy � 4/6/15 - HIC Registration Number Expira[ion Date HIC Company Name or HiC Registrant Name � � � 32 Taugwonk Spur,Al2 � kimberly.hendel r sener No.and Street @ 9 9Y.com � Stonington,CT 06378 860-535-3370 Email address Ci /Town,State,ZIP � Tele hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. t52.§ 25C(6)) Workers Compensation Insurance affidavit must be completed aud submitted with this application. Failure ro provide this affidavit will result in the denial of the Issuance of the building permi[. Signed Affidavit A[tached? Yes ..........C� No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Alteris Renewables dba RGS Energy to act on my behalf,in all matters relative to work authorized by this building permit application. see signed authorization form attached � � � Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER�OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attes[under[he pains and penalties of pequry that all of the inforznation I contained in this application is[rue and acwrate[o the best of my knowledge and understanding. ��� ��� '1/� Print Owner's or Authorized AgenPs Name(Glectronic Signature) Date NOTES: � 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (no[registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbihation program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Progam can be found at � www.mass.eov/oca Informa[ion on the Construction Supervisor License can be found at www.mass.�ov/dps 2. When substantial work is planned,provide the information below: Total floor azea(sq.ft.) � (including garage,finished basement/attics,decks or porch)� Gross living area(sq.ft.) � Habitable room count ' Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "1'otal Project Square Footage"may be substituted for"Total Project CosP' � . ' September 3, 2014 . To: Code Enforcement Division From: James A. Manc, Jr. P.E. Re: Engineer Statement for Hayes Residence, 13 Hancock St., Salem, MA - Solar Roof Mount Installation I have verified the adequacy and structural integrity of the existing 3 Main roofs (one layer shingles): 2" x 6" rafters at 16"c-c., having roof slope distance approx.l9'-0" with rafter span 14'-6", pitch 35 deg.; for mounting of solar panels and their installation will I satisfy the structural roof framing design-loading requirements of the Massachusetts I building code—780 CMR Residential Code 8th Ed. For the installation of the solaz mou�ting, the Unirac Solazmount rails will be anchored to the rafters with L-foot supports with Eco-Fasten Green-Fasten and CP-SQ Bracket located at 32" sp. on the center of the rafters and will be securely fastened to the rafters at I with 5/16"x 3 '/z" SS lag bolts as shown on drawing PV-A03. The mounting system has j been designed for wind speed criteria of 100 mph Exp. B and ground snow criteria of 40 psf. Landscape modules have vertical rails with horizontal unistrut channels below as shown on drawing PV-A02. � The Photovoltaic system a�d the mounting assemblies will comply with the applicable sections of tbe Residential Code and loading requirements of roof-mounted collectors. Thereby, I endorse the solaz panel installation and certify tbis design to be structurally adequate. Sincerely, ,B,�RA \nF M�SSq�h,GS 3�c ����� FT o_` ,�.nes�M �+ James A. Manc, Jr. ; c•"!��,�,5 w � ProfessionalEngineer �� �o!ssc��o w MA 36365 �°Fcssic�N��� c��3�>� �rv�'�� 10 High Mountain Road Ringwood, NJ 07456 cC: RGS Energy I ' � September 3, 2014 , . To: Code Enforcement Division From: James A. Manc, Jr. P.E. Re: Engineer Statement for Hayes Residence, 13 Hancock St., Salem, MA - Solar Roof Mount Installation I have verified the adequacy aud structural integrity of the existing 3 Main roofs (one layer shingles): 2" x 6" rafters at 16" o-c., having roof slope distance approxl9'-0" with rafter span 14'-6", pitch 35 deg.; for mouoting of solar panels and their installation will satisfy the structural roof framing design-loading requirements of the Massachusetts building code—780 CMR Residential Code 8th Ed. For the installation of the solar mounting, the Unirac Solarmount rails will be anchored to i the rafters with L-foot suppoRs with Eco-Fasten Green-Fasten and CP-SQ Bracket located at 32" sp. on the center of the rafters and will be securely fastened to the rafters at with 5/16"x 3 '/z" SS lag bolts as shown on drawing PV-A03. The mounting system has been designed for wind speed criteria of 100 mph Exp. B and ground snow criteria of 40 psf. Landscape modules have veRical rails with horizontal unistrut channels below as shown on drawing PV-A02. The Photovoltaic system and the mounting assemblies will comply with the applicable sections of the Residential Code and loading requirements of roof-mounted collectors. Thereby, l endorse the solar panel installation and certify this design w be structurally adequate. , Sincerely, � �\�nssq�H �� `��� ��` Mn�yY,.�P� '�� o nM�S� u � James A. Ma�,Jr. o No��'`'`'o w ProfessionalEngineer �A ,�f; ���`� � q p c i s ��' G��� � MA 36365 °gtitii�N�� / � �wrc7� �� 10 High Mountain Road Ringwood, NJ 07456 I cc: RGS Energy FOR,GQNSTRUCTION �' �o1/Io� � m ; �s����� � RGS • � � ENERGY � CICan Prnse4 Enqh[S.wln9s. � i � 32 Taugwonk Spur,Al2 - � Stonginton,CT 06378 � � Phone(860)535-3370 � � '13 H C� ST � � . Pax(413)�3-2225 �, � Equipment Located on Exterior WaIL• � GRID-TIED � (E) Utility Meter PHOTOVOLTAIC SYSTEM (N)PV AC Disconnect-Fused Equipment Located on Interior-Basement Wail: 7.00OkW DC @ STC (E) Main Service Panel- P.O.L HAYES, JOHN (N) PV Production Monitor- Enphase Envoy 13 HANCOCK STREET (N) PV AC Combiner Sub-Panel SALEM, MA 01970 Project# 10137256 DESIGNER: �an S�(Q(' „ R���R: Colin Roberts (N) PV A�y on Roof 3: �Eas�o��TE. 2014-0&28 7 Canadian Solar CS6P-250P Modules (N) PV Array on Roof 1: REVISIONS 7 Enphase Energy M215-60-2LL-S22-IG Micro-inverters 13 Canadian Solar CS6P-250P Moduies AsphalUComp. Shingle 13 Enphase Energy M21rr60-2LL-S22-IG Micro-Irnerters # By oate Notes 2"X 6" Rafters @ 16"O.C. ' AsphalUComp. Shingle Roof � 2"X 6" Rakers 16"O.C. 2 Pitch:35° a °e � Azimuth266° Pitch:35° � Azimuth:86° 3 q � o (E) Single Famity Dwelling o v 5 a 65 � O � Z � —1 A ° (N) PV Array on Roof 2: 8 Canadian Solar CS6P-250P Modules '� 0 8 Enphase Energy M21S60-2LL-S22-IG Micro-Inverters AsphalUComp. Shingle x 2"X 6" Rafters @ 16"O.C. ' Pitch:35° . m Azimuth:176° " a t m m ..�..... � . LL : y . : ... 44�_�,� ................................� . z _ : ............ , a ;�................. - (E) Property Line � � . o _ �,� 1/16��_ ��_0�� ' x SITE PLAN W E NOTE: ALL EXTERIOR CONDUIT ON ROOF AND UNDER EAVES . PV—AO� FINAL LOCATIONS TO BE DETERMINED DURING INSTALLATION g