Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11 GREENWAY RD - BUILDING INSPECTION (2)
(P2g The Commonwealth of Massachusetts b0 t Board of Building Regulations and Standards CITY OF N \�� Massachusetts State Building Code,780 CM SALEM R Revised Mar 2o11 Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling I This Section For Official Use Only _ Building Permit Number: Date Applied: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION I1.1 Pr ert Address• 1.2 Assessors Map&Parcel Numbers I.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq R) Frontage 01) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes[] SECTION 2: PROPERTY OWNERSHIP` 2.1 ow au��ol in Salem MA 01979 Name(Print) City,State,ZIP 11 Greenway rd 9785678763 Rogsnrse55@yahoo.com No,and Street 'telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK(check all that apply) New Constructi±51Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition Cl I Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Qesqrtiption of Proposed WorkZ: SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials 1.Building $ Zg S .�,0 1. Building Permit Fee:$ Indicate how fee is determined: 11 Q ❑Standard City/Town Application Fee 2.Electrical $ 1 1404 ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5. Mechanical (Fire $ -Suppression) Total All Fees:$ 1' f ��� „Q heck No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ l.,- 0 Paid in Full 0 Outstanding Balance Due: SECTIONS: CONSTRUCTION SERVICES SA Constructi n S4nrv�sor License(CSL) I UD(A 0P l License Number Ezptmtion ate Na df. A der ..1- List CSL Type(see below) No. gI!reel UU 1 n Type Description U Unrestricted(Buildings up to 35.000 cu.R. R Restricted 1&2 Family Dwelling City�/rown,StState,ZIP 'I M Masonry RC Roofing Coverin WS Window and Siding SF Solid Fuel Burning Appliances 1 Insulation Tele hone Email address D Demolition 5.2 Registered Home lmp+ro((XX''ent/e''��ntContractor(HIC) 76 � I • I(� 1 wor HIC Registration Number Expiration Date HIC Company Net t.pr;.}IIC R istrant Nam ` Na.and Street ot(1[ i., 1 (n yt ��1,11L 'Itl�j� 1 ��13QC�MJ —�V Email address Ci /Town,State,.ZIP -t I h�� �+1� Telephonehodl�.L SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .........iM' No..............❑ SECTION 7s:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject pro erty,hereby authorize yA y� h/.Lr,O. to act on my behalf,in all afters tative to work authorized by this building permit application. Paul Coffin (a4ep. _ 11/3/16 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER!OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print 0 er- s�or Authorized Agent' Name(Electronic Signature). Date NOTES: (. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www:mass. og v/oca Information on the Construction Supervisor License can be found at www.mass. ov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basementlattics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 1 P 1 wpawLnzoleaw xldZ Office of Consumer Affairs �(nd Business Regulation 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Repfstratton. °1"1413 Type: ;Supplement Cad VIVINT SOLAR DEVELOPER LLC. expiration. WPM KYLE GREENE -- — -- r -- 3001 N THANKSGIVING WAY SUITE 500 — - ---- --— — — LEHI, UT 84043 Upda2A4drai:and return nerd:MerR rosaoa(ar caep4e. eur a teir•mnr Z2 Addrace 9e6ewal: Empleymut ❑East Cad yi t y 1 M ssachusetts - Dersartment of Pubtic Safety �6 W. 80ard of'801dina Regulations and Standards r--,. rt icensc: CS-108068 „v t�� , � KYLE GREENS l,� y,, « 44 MAIN STREET r; a North Reading M�A 018` 4 i t Expiration * Commvissioner 0112012018 r. A�® CERTIFICATE OF LIABILITY INSURANCE DATE rz rzo"6°"" ' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. 122517TH STREET,SUITE 1300 PNONE ac No DENVER,CO 80202-5534 _ E+wL Attn:Denver.CenRequest@marsh.com I Fax:212-948-4381 ADDRESS: INSURE S AFFORDING COVERAGE NAICB INSURER A:Axis Specialty Europe INSURED Mvint Solar,Inc: INSURER B:Zunch American Insurance Company 16535 Mvint Solar Developer LLC INSURER C:Ame.am Zurich Insurance Company 40142 Uvint Solar Provider LLC INSURER D:NIA NIA 3301 North Thanksgiving Way,Suite 500 Lehi,UT 84043 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002920007-12 REVISION NUMBER:O THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLSUSR POLICYEFF POUCYEXP LTR TYPE OF INSURANCE POUCYNUMBER flmhffo YYYYlMM/OOIYYYY LIMITS A X COMMERCIAL GENERAL UABIUTY 3776500116EN 010/2016 0129/2017 EACH OCCURRENCE $ 25,000,000 CLAIMS-MADE F_x]OCCUR PREMISES Ea occunence $ 1,000,000 N ED EXP(Any one person) $ 10,000 PERSONAL a ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 25,000,000 X POLICY °E T F1 LOC PRODUCTS-COMP/OP AGG $ 25,000,000 OTHER $ B AUTOMOBILE LIABILITY RAPSM601501 111012015 11/01/2016 COMBINED SINGLE LIMIT $ Ea accident 1,000,000 Ix ANY AUTO BODILY INJURY(Per person) $ ALL OS SCHEDULED BODILY INJURY Per accident $ AUTOS AUTOS ( 1 HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per acci Comp/Coll Dept $ 1,000 UMBRELLA LAB OCCUR EACH OCCURRENCE $ EXCESS LU18 CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ - $ C WORKERS COMPENSATION WC509601301 111012015 11I0112016 X J PER OTH- ANUEMPLOYERS'LIABIUTY YIN STATUTE ER ANY PROPRIETOR/PARTNEWEXECUTIVE AZ,CA,CT,HI,MD,NJ,NY,NV,NM, El EACH ACCIDENT $ 1,000,000 OFFICEWMEMBERF CLUDED9 NIA (Mandatory in NH) OR,PA,UT E.L.DISEASE-EA EMPLOYEE $ 1,000,000 B If yes.describe under WC509601401 MA 11N112015 11/Oi/2016 OESCRIPTIONOFOPERATIONSbelow ( ) E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 1q1,AdlNonal Rem ftS Sbhedule,rrey be atlached if more space is required) The Certificate Holder and others as defined in the wren agreement are included as additional insured where required by written contract with respect to General Lability.This insurance is primary and non- contributory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract Waiver of subrogation is applicable where required by written contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe ,77r. fQca(s-_ ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts a Department of IndustrialAccidents 1 1 Congress Street,Suite 100 Boston, MA 02114-2017 www.mass gov/dia ��'orkers'Compensation Insurance Affidavit:Builders/Contracters/Electricians/Plumbers. TO BE FH.ED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Ixalbiy. Name(Business/Organization/individual):Vi'Ant Solar Developer LLC Address:1800 W Ashton Blvd City/State/Zip;Lehi, UT 84043 Phone#: 5"77-2974 An you an employer?Check the appropriate box: Type of project(required): I.�r I am a employer with 254 employees(full and/or pan-time).* 7. ❑New construction 2.rl 1 am a sole proprietor or paanenhi and have onemployees workin for me in pg 8. ❑Remodeling anY capacity.[No workers'comp,insurance required.] 3D I era a homeowner doing all work myself.[No workan'comp.insurancerequired.]t 9. ❑Demolition 4.❑I am a homeowner an wnac d will be hiring utors to conduct all work an my property. 1 will 10❑Building addition ensure that all mmracton citha have worker'compensation insurance in am sole 1 I.❑Electrical repairs or additions proprietors with w employees. 12.❑Plumbing repairs or additions 5.[]1 am a general contractor and 1 have hired roe sub-comrctors listed on the attached sheet.These subaa•concion es have employe and have workers'comp.inau ]3. rance.t ❑ROOFalrs 6.❑We art a corporation and in officers have exercised their right of exemption per MGL c. 14.❑Other 152,§1(4),and we have no employees.[No workers'comp,insurrxe naluired.] -Any applicant that cheeks box al most also fill our the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they me doing all work and then hire outride conlractors must submit a new affidavit indicating such. ;Contrcters that check this box must attached an additional sheet showing the name of the subaronnacton and some whether or not Nose entities have employees. If the sub-comWors have employees,they must provide their workers'comp.policy number.. f am an employer that is providing workers't'ompensation insurance for my employees. Below is the polity andjob site information. Insurance Company Name:Marsh USA Inc Policy#or Self-ins.Lic.#::^WC55009�600113,002 ' f ('� _ Expiration Date:11/0`112017 Job'Site Address, \ 't'JV g''P \� aq �X City/State/Zip: \ a Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may he forwarded to the Office of Investigations of the DIA for insurance coverage verification. l do hereby certify under th and penahies ofiterf rty that the information provided above is true and correct. Sianature: r � Date: 2"l Phone#, �J�J�J ' U l "f� /�1q ` 1 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City(fown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: p MBINC EHi,SJ ❑ ROOF VEHi151 i 8 �^To m Qom I M i BIBN PV SYSTEM SIZE 6.480 kW DC C) to WITH J 1R50URJPF9W.PdOBB MOOVLES I I �SKYLIGNT W0 I I BAC%OFOCHMOOULE o TIES JUNCTIONNBBOX TOO ELECTRICAL WN , WU ----------- I j ® ,B aoo� E It, dLLOCRPBLE DISCONNECT SWITCH,& UTILT'MEiER LOCPI,ON:TIEIMO , ®� RXBCB,� � I � ME,E ❑ Q � JVN %PTTPL (A I += UCH JUNCTION GWOUN BC,NO - m JV LTIDNBO%DFFROOFpRETORE Q I I O � LYL I 3 Roof Type:Comp.Single � ' KXX Roof Section1 Q I I $ O RmT� F Po, L„ O ORoof Section 2 Z 3 2 Eonwx =>,E W Rp TIT. R ORoof Section 3 W I o S p 3 HUSTIT. I I >00000ISO I I SHEET NAME'. , F J Na L---------------------------------------------------------------------------J SHEET NUMBER: PV SYSTEM SITE PLAN O SCALE:3116-=1'-0" a CLAP+ATTACHMENT COUPLING CLAMP ASSEMBLY (INCLUDES GLIDER) LEAF SPRING 40 � I I mill" Ig GLIDER ¢w f u MODULE CLAMP+ATTACHMENT a rcw¢ PERMITTED o `�y? COUPLING CLAMP SPACING STRUT NUT RAFTER ( ECOX BASE SEALING WASHER RAFTER FLASHING COMP SHINGLES L- I l l i l I_ L=PORTRAIT I MODULE O CLAMP SPACING �' Z 5/16"x4 1/2" SS LAG SCREW IL=LANDSCAPE CLAMP SPACING TORQUE=13t2 FT.LBSvi MODULES IN PORTRAIT/LANDSPACE w3.o NOT TO-E MOUNT DETAIL- ECOX z re WITH METAL FLASHING w 3.0 NOT TO SCALE B Z MOUNTING s G w 3.0 DETAIL CANTILEVER U3 OR LESS s m L=MAX 64" 8 PV MODULES,TYP.MOUNT COUPLING CLAMP - N OF COMP SHINGLE ROOF, / MODULE N SHEET PARALLEL TO ROOF PLANE Z J o F RAFTER O � p PV ARRAY TYP. ELEVATION SHEET NOT TO SLME NUMBER (��) : PV SYSTEM MOUNTING DETAIL MB N t w3.0 NOT TO E , a v Photoyoltaic S stem Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) 1 2 OC System Size 6480 Tag4 Description Wire Gauge IT of Conductors/Color Conduit Type Conduit size m AC System Sixe 76W 1PV Wire 30 AWG 2(V+,V-) N/A-Free Air N/A-Free Air o .Total Module Count 24 1Bare Copper GmundEGC/GEC) 6AWG IBARE N/A-Free Air N/A-Free Air c o 2THWN-2 10 AWG 4(2V+,2V-)B/R PVC 1.1for a m 1 2 2THWN-2-Ground 8AWG 1(GRN) PVC 1" to i 3 THWN-2 8AWG 3(1L1,M.IN)B/R/W PVC 1" `•' 3 THWN-2-Ground 8AWG 1(GRN) PVC 1" up ¢" ty 4THWN-2 6AWG 3(111,11.2,1N)B/R/W PVC 1" st &isti na Modul e l Mormat on: Type:in na Sol or TRM-255 PDOSGS 4THWN-2-Ground 8AWG 1(GRN) PVC In eovnt 24 Esisti,PVCOmemer Panel Existing inverter information: Type:M215-60-2 W522-IG ILL' count24 V 0 N VIS IBLE LOCKABLE SREC/ANSI METER VISIOEE LOCKABLEvia KNIFE'A/C MILHANK 100AOR 'KNIFE'ArC - DISCONNECT EQUIVALENT DISCONNECT Siemens Uri U5934-XL-OIG V240V FUSED rAV240V NEMA3 OR UNFUSEONEMA3 EQUIVAL NT OR EOUIVP1ENi V M f3O) to v, as o sosolar cage an SE7.001 A H m Yanbrms W ANSI C1ZA-2008 Pal no of Interconnection,Supply Side 705.121Ai,Conforms to NEC 2014 > 2 w SQUME D D222NR0 240VINAFWEP w �^ REMA30fl EQUIVNF I NTse NT F F j w ¢ on STRING 2:13 PV t .. 13 �/ TERMINATONS S us SHEEE T MODULES IM• Exialing240V/200A NAME: Service Panel, PM1ases A Main 2 Disconnect m c 3 MING 1:11 PV 1 2 11 \ 7 A MODULES 3 qdy / ro C U I q SHEET NUMBER: 24W MODULES PER INVERTER IIINIMUMGECSIZE4AWG STC VISINE/LOCKIBLE'KNIFFA/C COPPER 1y DISCONNECTINSIGHTOFTAP W t) DC Safety Switch Conductor Calculations Rated for max operating condition of inverter PV Module Rating IS STC -Wire gauge calculated from NEC code 310.15(B)(16)with ambient temperature calculations NEC 690.35 compliant c o 'opens all ungrounded contl Module Make/Model JAP6-60-270/4BB from NEC 330.15(2)(a). uc[ors a > ce Max Power-Point Current(Imp) 8.65 Amps For"On Roof"conductors we use the 90'C column ampaciry,OS"-3.5"off-the-roof temperature a a m Optimizer Solar Edge P300 Max Power-Point Voltage(Vmp) 31.23 Volts adjustment from 310.15(9)(3)(c),and raceway fill adjustments from 310.15(B)(16). i f Open-Circuit Voltage(Vic) 38.48 Volts For"Off Roof'conductors we use the 25-C column ampaciry,orthe 90'C column ampaciry with a p w u DC Input Power 300 Watts the relevan[ambienttempeature and ncewayfill adjustments,whicheveris less. w ¢ DC Max Input Voltage 48 Volts Short-Clrcui[Current(Isc) 9.26 Amps The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous '" N >' DC Max input Current 12.5 Amps Max Series Fuse(OCPD) 15 Amps duty uprated output current. DC Max Output Current 15 Amps Nom.Maximum Power at SIC(Pmax) 220 Watts Calculation Example-Wire Rating(90-C)x Ambient Tempeature Adjustment x Conduit Fill Max String Rating 5250 Watts Maximum system Voltage DC 1000V(UL) Adjustment>=Continuous Duty Output Current Inverter Make/Model SE260OA-US Voc Tem perature Coefficient -0.33 %/C (On Roof,Tag 2):10 gauge wire rated for 40 A, 40Ax O.76 x 0.8(4 Conductors=24.32 A>= CEC Efficiency 97.5 % 18.75A AC Operating Voltage 240 Volts PV Module Rating @STC (Off Roof,Tag3):Sgaugewlmratedfor50A, 50A>=39.58A L Continuous Max Output Current 32 Amps Module Make/Model Trina Solar TSM-255 PD05.08 DC Maximum Input Current 23 Amps Max Power-Point Current 8.32 Amps 0 Short Circuit Current 40 Amps Max Power-Point Voltage(Vol 30.5 Volts N Open-Ci rcuit Voltage(Voc) 38.1 Volts Max Ou[ it Current 40 20ms _• Short-Circuit Curren[(Isc) 8.88 Amps sG Max Series Fuse(OCPD) 15 Amps m Nom.Maximum Power at STC(Pmax) 255 Watts Maxim um System Voltage 1000 V(I EC)/600 V(UL) Voc Temperature Coefficient -0.32 %/C Inverter Make/Model M215-60-2LL-S22-IG Max Dc Volt Rating 45 yolts Max Power at 40C 215 Watts AC Output Current According to NEC 690.8(B)(1) 31.67 Amps Nominal AC Voltage 240 Volts Nominal AC Voltage 240 11 Volts Max AC Current 0.9 Amps THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY ANO SOLAR) p OCPD Calculations Max OCPD Rating 2D Amps ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE y Max Number of Panels/Circuit 12 WITH NEC 690.8,TABLES 310.15(8)(2)(a),310.15(B)(3)(a), Breakers sized according to continuous duty output current PV circuit nominal current based off Short Circuit Current 1.05 Amps 310.35(B)(3)(c),310.15(6)(16),CHAPTER 9 TABLE 4,5,&9. inverter continuous output current k(1.25(NEC code 210.19(A)(1)(a)). g m LOCATION SPECIFIC TEMPERATURE OBTAINED FROM ASHRAE 2013 in .. DATA TABLES. Inverter 1:SE2600 A-US-U Max Output=31.62 A x 1.25(NEC code 210.19(A)(1)(a)) = w N ASHRAE 2013- =39.58 A<40 A(OCPO) system output current w/continuous duty 39.58<40A(System OCPD) c m Highest Monthly 2%DB Design Temp:32.5 Celsius z w z m Lowest Min.Mean Extreme DB:-23.9 Celsius a a = N ~ ~ < n Other Notes SHEET •ALL INTERIOR RACEWAYS CARRYING DC CURRENT SHALL BE METALLIC NAME: •All ampaciry calculations are made in compliance with NEC 220.5(B) u m «o or as SHEET NUMBER: N W 1 _ vivinto solar 1800 W Ashton Blvd. Structural Group Lehi, LIT84043 Jon P. Ward, SE, PE Clint C. Karren, PE Structural Engineering Manager Structural Engineering Manager jon.wardt?a vivintso/ar.com clint.karrenOa vivintsolaccorn November 05, 2016 Mr. Dan Rock, Project Manager Vivint Solar 1800 W Ashton Blvd. Lehi, LIT 84043 Re: Structural Engineering Services Coffin Residence 11 Greenway Rd, Salem, MA S-5296553; MA-01 Dear Mr. Rock: Pursuant to your request,we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a representative from our office under my supervision identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. 5. Previous structural evaluation for the existing solar system completed by Vivint Solar on February, 25 2014. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof section is composed of 2x6 dimensional lumber at 16" on center and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. • Roof section is composed of assumed 2x6 dimensional lumber at 16" on center and a single layer of roofing. The attic space is finished and photos indicate that there was no access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 25 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B,Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page t of vivi 11 . solar B. Loading Criteria 8 PSF= Dead Load (roofing/framing) 40 PSF= Ground Snow Load 3 PSF = Dead Load (solar Panels/mounting hardware) Total Dead Load= 11 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual, which can be found on the Ecolibrium Solar website (www.ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 1/2" thick and mounted 4 1/2" off the roof for a total height off the existing roof of 6".At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 'h", is less than the maximum allowable per connection and therefore is adequate. 4. Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four (4) spaces or 64" o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. AA OF Regards, N p �G Jon P. Ward, SE, PE pR MA License No. 52584 NO. 525 � a ��RFO/STEREO��� SS/ONAL V/ tVIII� Page 2of2 vivint. solar 0 n'rMy',J�r RESIDENTIAL SOLAR POWER PURCHASE AGREEMENT B "L Y Y Y oSo I a r� Customer Name and Contact Information: Transaction Date�l Name(s) Paul Coffin Service No.2016-11-04 Installation Location Address 11 GREENWAY RD Approximate Start and 11 GREENWAY RD SALEM MA 01970-286 Completion Date SALEM 4 2017-05-03 Home Phone 97$8085082 MA 01970-286 a Cell Phone 9788085082 E-Mail tenderlipss@comcast.net Our Promises + We will design,install,maintain, repair, + We will not place a lien on Your Property. monitor,and insure the System at no additional cost to You. + You are free to cancel this Agreement any time prior to Our commencement of + We warranty all of Our work,and that Our installation work at Your Property. roof penetrations will be watertight,for the initial 20 year term. + The Energy Price includes a$5 monthly discount for paying by automatic debit + Your Energy Price will not increase by more from Your bank account. than 2.9%per year. + You will not be responsible for any + After five years,if You need to make property tax assessed on the System. Property repairs,We will remove and reinstall the System if You pay Our + We will fix or pay for any damage We may estimated costs. cause to Your Property or belongings. Your Commitment - .' Pay for the Energy produced by the System. • Maintain a broadband internet connection. •-Keep Your roof in good condition throughout Continue service.with Your Utility for any the Term. energy used above and beyond the System's - production. • Respond to Our sales and support teams ' when scheduling and completing paperwork. At the Endof Your Initial Term You can renew the Agreement - You can request that We remove the System for a subsequent term;. at no additional cost. • You can purchase the System;or If You Move We guarantee You can transfer the • You can relocate the System.to Your Agreement to the new owner,regardless of new home;or credit rating; . _ After the sixth anniversary,You can purchase • You can prepay the Agreement; the System. Vivint Solar Developer, LLC(EIN: 80-0756438)is a licensed contractor in each state in which we operate,for information about our contractor licenses please visit www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN &OPT-OUT NOTICE BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: support@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 84043 Phone 877.404.4129 1 Fax 801.765.5758 Copyright©2016 Vivint Solar Developer,LLC All Rights Reserved PPA(8/2016,v3.2.2)1 Page 1 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. INCORPORATED DOCUMENTS. These documents G. You have the right to require Us to have a are incorporated into this Agreement and apply to the performance and payment bond. relationship between You and Us: (1) Residential Solar H. CUSTOMER'S RIGHT TO CANCEL. YOU MAY Power Purchase Agreement, (2) Exhibit A: Notice of CANCEL THIS CONTRACT AT ANY TIME BEFORE THE Cancellation, (3) Exhibit B: State Notices and LATER OF: (1) MIDNIGHT OF THE THIRD (3RD) Disclosures, (4) Exhibit C: Certificates of Insurance, BUSINESS DAY AFTER THE TRANSACTION DATE, OR and (5) Customer Packet. (11) THE START OF INSTALLATION OF THE SYSTEM OR B. WE HAVE NOT GUARANTEED, PROMISED OR ANY OTHER WORK WE PERFORM ON YOUR OTHERWISE REPRESENTED ANY REDUCTION IN PROPERTY. IF YOU WISH TO CANCEL THIS CONTRACT, ELECTRICITY COSTS IN RELATION TO THE SYSTEM YOU MUST EITHER: (1) SEND A SIGNED AND DATED THAT WILL BE INSTALLED ON YOUR PROPERTY. WRITTEN NOTICE OF CANCELLATION BY MAIL, E-MAIL, C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES OR FAX; OR (2) PERSONALLY DELIVER A SIGNED AND UNLAWFULLY OR COMMIT ANY BREACH OF THE DATED WRITTEN NOTICE OF CANCELLATION TO: PEACE TO REMOVE GOODS INSTALLED UNDER THIS VIVINT SOLAR DEVELOPER, LLC, 1800 W ASHTON AGREEMENT. BLVD, LEHI, UT 84043, ATTN: PROCESSING D. DO NOT SIGN THIS AGREEMENT BEFORE YOU DEPARTMENT. IF YOU CANCEL THIS CONTRACT HAVE READ ALL OF ITS PAGES. You acknowledge that WITHIN SUCH PERIOD, YOU ARE ENTITLED TO A FULL You have read and received a legible copy of this REFUND OF YOUR MONEY. REFUNDS MUST BE MADE Agreement, that We have signed the Agreement, and WITHIN 10 DAYS OF OUR RECEIPT OF THE that You have read and received a legible copy of every CANCELLATION NOTICE. SEE THE ATTACHED NOTICE document that We have signed during the OF CANCELLATION FOR AN EXPLANATION OF THIS negotiation. RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO YOU THE "NOTICE OF CANCELLATION". A SALES REPRESENTATIVE. I. Unless You are provided with a longer period in F. DO NOT SIGN THIS AGREEMENT IF THIS Exhibit A,You may not terminate this Agreement after AGREEMENT CONTAINS ANY BLANK SPACES. You are three(3)business days of the Transaction Date. If You entitled to a completely filled in copy of this seek to cancel thereafter, then You will forfeit any Agreement, signed by both You and Us, before any amounts previously paid and You may owe Us the work may be started. Default Payment. VIVINT SOLAR DEVELOPER, LLC CUSTOMER(S): Signature: V- Signature: Printed Name: Serge Dldenko Printed Name: Paul Coffin Salesperson No.: Date: 2016-11-04 Date: 2016-11-04 Signature: Printed Name: Date: 2016-11-04 Copyright© 2016 Vivint Solar Developer, LLC. All Rights Reserved PPA(812016,v3.2.2)I Page 18 EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 5296553 Street Address Line 1:' Street Address Line 2: City: State: Zip: Country: System Info Module Manufacturer:JA Solar Module Model: JAP6-60-270/4BB Module Quantity: 24 Array Size (DC watts): 6480.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: v.SE7600A-US(240V) Project Design Variables Module Weight: 40.124084 Ibs Module Length: 64.960665 in Module Width: 39.0157691 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 1.5 Exposure Category: B Importance Factor: I Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load- Lateral: 288 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar Plane Calculations (ASCE 7-10): North East Roof 3 Roof Shape: Edge and Corner Dimension: 3.4608195196206424 ft Attachment Type: Stagger Attachments:Yes Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 34.6081951962064 ft Include North Row Extensions: No Roof Slope: 25.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 0.82 0.82 0.82 - Roof Snow Load 22.0 22.0 22.0 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 22.0 22.0 22.0 psf Downslope:Load Combination 3 9.4 9.4 9.4 psf Down: Load Combination 3 20.2 20.2 20.2 psf Down: Load Combination 5 11.7 11.7 11.7 psf Down: Load Combination 6a 22.8 22.8 22.8 psf Up: Load Combination 7 -10.4 -17.9 -27.5 psf Down Max 22.8 22.8 22.8 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 68.7 68.7 62.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 22.9 22.9 20.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 53.3 53.3 48.5 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.8 17.8 16.2 in EcolibriumSolar Layout Skirt e Coupling ® End Coupling Note: If the total width of a continuous array exceeds 35 ft, break 0 Clamp array to allow for thermal expansion and contraction. See 0 End Clamp Installation Guide for details. ® North Row Extension Warning: PV Modules may need to be shifted with respect to roof 0 Row-to-Row Bonding Clip/Bonding Jumper trusses to comply with maximum allowable overhang. EcolibriurnSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 18 Weight of Modules: 722 Ibs Weight of Mounting System: 62 Ibs Total Plane Weight: 784 Ibs Total Plane Array Area: 317 ft2 Distributed Weight: 2.48 psf Number of Attachments: 31 Weight per Attachment Point: 25 Ibs Roof Design Variables Design Load- Downward: 918 Ibf Design Load- Upward: 720 Ibf Design Load- Downslope: 460 Ibf Design Load- Lateral:252 Ibf EcolibriunnSolar Plane Calculations (ASCE 7-10): North West Roof Roof Shape: Edge and Corner Dimension: 3.0 ft Attachment Type: Stagger Attachments: Yes Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 11.8469904968018 ft Include North Row Extensions: No Roof Slope: 25.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 0.82 0.82 0.82 Roof Snow Load 22.0 22.0 22.0 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 22.0 22.0 22.0 psf Downslope: Load Combination 3 9.4 9.4 9.4 psf Down: Load Combination 3 20.2 20.2 20.2 psf Down: Load Combination 5 11.7 11.7 11.7 psf Down: Load Combination 6a 22.8 22.8 22.8 psf Up: Load Combination 7 -10.4 -17.9 -27.5 psf Down Max 22.8 22.8 22.8 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 68.7 68.7 62.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 22.9 22.9 20.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 53.3 53.3 48.5 in Max Spacing Between Attachments With Rafter(rruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.8 17.8 16.2 in EcolibriumSolar Layout C �) Skirt Coupling ® End Coupling Note: If the total width of a continuous array exceeds 35 ft, break ® Clamp array to allow for thermal expansion and contraction. See End Clamp Installation Guide for details. O North Row Extension Warning: PV Modules may need to be shifted with respect to roof 0 Row-to-Row Bonding Clip I Bonding Jumper trusses to comply with maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 3 Weight of Modules: 120 Ibs Weight of Mounting System: 16 Ibs Total Plane Weight: 136 Ibs Total Plane Array Area: 53 ft2 Distributed Weight: 2.58 psf Number of Attachments: 8 Weight per Attachment Point: 17 Ibs Roof Design Variables Design Load- Downward: 918 Ibf Design Load- Upward: 720 Ibf Design Load- Downslope: 460 Ibf Design Load- Lateral:252 Ibf EcolibriurnSolar Plane Calculations (ASCE 7-10): South East Roof Roof Shape: Edge and Corner Dimension: 3.0 ft Attachment Type: Stagger Attachments: Yes Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 11.8469904906907 ft Include North Row Extensions: No Roof Slope: 25.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 0.82 0.82 0.82 Roof Snow Load 22.0 22.0 22.0 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 22.0 22.0 22.0 psf Downslope:Load Combination 3 9.4 9.4 9.4 psf Down:Load Combination 3 20.2 20.2 20.2 psf Down:Load Combination 5 11.7 11.7 11.7 psf Down: Load Combination 6a 22.8 22.8 22.8 psf Up:Load Combination 7 -10.4 -17.9 -27.5 psf Down Max 22.8 22.8 22.8 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 68.7 68.7 62.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array - 22.9 22.9 20.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 53.3 53.3 48.5 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.8 17.8 16.2 in EcolibriumSolar Layout I Il�,l ill U U Skirt e Coupling e End Coupling Note: If the total width of a continuous array exceeds 35 ft, break ® Clamp array to allow for thermal expansion and contraction. See 0 End Clamp Installation Guide for details. • North Row Extension Warning: PV Modules may need to be shifted with respect to roof 0 Row-to-Row Bonding Clip I Bonding Jumper trusses to comply with maximum allowable overhang. EcolibriurnSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 3 Weight of Modules: 120 Ibs Weight of Mounting System: 16 Ibs Total Plane Weight: 136lbs Total Plane Array Area: 53 ft2 Distributed Weight: 2.58 psf Number of Attachments: 8 Weight per Attachment Point: 17 Ibs Roof Design Variables Design Load- Downward: 918 Ibf Design Load- Upward: 720 Ibf Design Load- Downslope:460 Ibf Design Load- Lateral: 252 Ibf EcolibriumSolar Bill Of Materials Part Name Quantity ES10260 EcoX Row-to-Row Bonding Clip 7 ES10121 EcoX Coupling Assembly 18 ES10146 EcoX End Coupling 7 ES10103 EcoX Clamp Assembly 32 ES10136 EcoX End Clamp Assembly 15 ES10144 EcoX Junction Box Bracket 3 (Optional) ES10132 EcoX Power Accessory Bracket 24 ES10333 PV Cable Clip 120 ES10334 4 PV Cable Clip 48 ES10195 EcoX Base, Comp Shingle 47 ES10197 EcoX Flashing, Comp Shingle 47