Loading...
10 FRANCIS RD - BUILDING INSPECTION 14tl 4Sr.L The Commonwealth of Massachusetts 1,115 u LU Board of Building Regulations and Standards CITY OF t ALEM Massachusetts State Building Code,780 CMR SdMar t Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Dat pplied: 1 / 1wI I Building Official(Print Name) Signature ate SECTION 1:SITE INFORMATION `—...e 1.1 erop y Address: 1.2 Assessors Map&Parcel Numbers v—�� no Map Number Parcel Number l.la Is this an accepted street?yes 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Public❑ Private❑ Check if yes❑ p W y SECTION 2: PROPERTY OWNERSHIP' 2' to eat° amir'e Salem MA 01979 Name(Print) City,State,ZIP 10 francis rd 9787895785 Legerm@comcast.net No.and Street - Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construed Existing Building❑ Owner-Occupied ❑ I Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other Cl Specify: Brief es rip�tion of Proposed Woks: ' SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials) 1.Building $ t l%okp—3 . � 1. Building Permit Fee:$ Indicate how fee is determined: [I Standard City/Town Application Fee 2.Electrical $ 1\0 S-2' ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Total All Fees:$ Suppression) 0� Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $'a i3 I b ❑paid in Full 0 Outstanding Balance Due: SECTION5: CONSTRUCTION SERVICES Co S �IA�.U��I�I�O� .l nstruction Supervisor License(CSL) I p��&& )- l7 1 -- License Number Expiration ale Na Jr, filer I ) Il ((,i( List CSL Type(see below) y No. treat Type Description U Unrestricted(Buildings up to 35.000 cu.R. C R Restricted 1Nc2 FamilyDwelling own;State,/.IP T M Masonry RC Roofing Coverin WS Window and Siding SF Solid Fuel Burning Appliances u'JJ , ��Y�LIYt'L.�o�U1�1Sd (y:Q I Insulation Telephone - I Email.address D Demolition 5.2 Registered Home lmproementContractor(HIC) 7UYA- 1�1�� or HIC Registration Number Expiration Date HIC Company Nan r IIC Registrant Nam No.and Street ` ;'� .�g1�P2 Ema address 1a < Email address City/Town, State,.ZIP OU Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .........itr No...........,13 SECTION 7s:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT erty 1,as Owner of the subject prop ,hereby authorize W'U�.. I Qo hr to act on my behalf,in all matters relatry o woi k authorized by this building permit application. Robert Camire 11/25/16 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. YW,t Upme �s h I —111 Print O er4s or Authoriie(T Agent' Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass. ovG /oca Information on the Construction Supervisor License can be found at www.mass.gov/dCs '2. When substantial work is planned,provide the information below: Total Floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth ojMassachusetts c Department of IndustrialAccidents I Congress Street,Suite 100 Boston, MA 01114-2017 www.massgov/dia 1y orkers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILET)WITH THE PERMITTING AUTHORITY. Appllcamt Information Please Print Legibly Name (Business/Organimtiontmdiaiduap:Vvint Solar Developer LLC Address:1800 W Ashton Blvd City/State/Zip:Lehi,UT 84043 Phone#:855-877-2974 An you an employer"Check the appropriate box: Type of project(required): LEJ lam a employer with 254 employees(full andor part.time).' ), ❑New construction 2. lama a sole proprietor or partnership and have no employees working for me in ❑ 8: ❑Remodeling any capacity.[No workers'comp,insurance required.] 9. Demolition 3.❑1 am a homeowner doing all work myself[No workers'omtip.insurance required.!r ❑ 10❑Building addition 4.❑I am a homrowner and will be hiring contractors to conduct all work on my property. I will cmum that all contractors either have workers'compensation insurance or are sole I I.❑Electrical repairs or additions Proprietors with no employees. 12.❑Plumbing repairs or additions 5.rl[am a general contractor and I have hired the sub-contmdon listed on the attached shed. I3.�Roof repairs These suMconeaclors have employees and have workers'romp.insumncc.t 6.❑we am.corporation and its officers have exercised[heir right oCcxcmplion per MGL c. 14.❑Other 152,¢I(4),and we have no employees.(No worked comp,insurance required.) 'Any applicant that checks box al most also fill our the section below showing thdrworkas'earrgrensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit anew affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors aryl stain whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.. lam an employer that is providing workers'compensation insurance for my emplayees. Below is the polity and job site information. Insurance Company NameYarsh USA Inc Policy#or Self-ins.Lic.#:WC509601302 Expiration Date:1 1/011201 7 �y Job Site Address, l� Q�`� P City/State/Zip: 1 A Q QaQQ1M Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,¢25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may he forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under t and penalties ofperjury that the information provided above s ifue and correct. Sienailwyl "'`T Dale: Phone#- Official use only. Do not write in this area,to be completed by city or town official. City or Town:. - PermitiLicense is Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: AC4® CERTIFICATE OF LIABILITY INSURANCE DATE(Mols MIDDMY on7n THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER($), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: H the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 12251TTH STREET,SUITE 1300 PHONE FAX No: DENVER,CO 80202-5534 E-MAIL Attu:Denver.CertRequest(olmarsh.com I Fu:212-948-4381 ADDRESS: INSURERS AFFORDING COVERAGE NAICd INSURER A:Axis Specialty Europe INSURED Vivint Solar,Inc. INSURERS:Zurich Amerman Insurance Company 16535 Vivint Solar Developer LLC INsuRERc:American Zurich insurance Company 40142 Vivint Solar Provider LLC INSURER D:NIA NIA 1800 W.Ashton Blvd. Lehi,UT 84043 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002920007-19 REVISION NUMBER:3 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF ADO SUER POLICY EFF POLICYEXP LTR POLICY NUMBER (MMMONM fMNUDDNYYY) UNITS A X COMMERCIAL GENERALUABIUTY 3776500116EN 01012016 0112912017 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE ff]OCCUR DAMAG RENTED PREMISES(Ea oaurrence 1 $ 1,000,000 MED EXP(Any one person) $ 10,000 PERSONAL S ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY F7 ECTT 11 LOC PRODUCTS-COMPIOP AGO $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY BAP509601502 11101016 11101/2017 COMBINED SINGLE LIMIT $ Ea accident 1,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per ecdden0 $ X NON-OWNED PROPERTY DAMAGE $ XIHIRED AUTOS AUTOS Per accident Comp/Coll Ded $ 1,000 A X UMBRELLALIAB X OCCUR 3776500116EN 01012016 0112912017 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAR CLAIMS-MADE GL Only AGGREGATE $ 5,000,000 LIED I I RETENTION$ 1 $ C WORKERS COMPENSATION WC509601302 1110112016 1110112017 X PER OTH- AND EMPLOYERS'LIABILnY YIN STATUTE ER CT FL H MA MD NJ ANY PROPRIETO"ARTNERIEXECUTIVE AZ,CA, , , , , , , EL EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? Efl NIA (Mandatory in NH) NM,NY,PA,SC,TX,UT E.L.DISEASE-EA EMPLOYEE $ 1.000,000 B If yes,describe under WC509601402 MA 11101Y2016 1110112017 1,000,000 DE SCRIPTION OF OPERATIONS below ( ) EL.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedula,may be seethed if more apace Is required) The Certificate Holder and others as defined in the written agreement are included as additional insured where required by written contract with respect to General Liability.This insurance is pnmary and non- Contributory war any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract.Waiver of subrogation is applicable where required by written contact with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe yr,(j�r-Jn. fQ,celsG ©1988.2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD y 1 Office of Consumer Affairs d Business Regulation 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Reglelralbnc. 170848 Tvpea SUPplemenl Card VIVINT SOLAR DEVELOPER LLC. Lzpira8on: 1l8Y2078 KYLE GREENE 3301 N THANKSGIVING WAY SUITE 500 - W LEHI. UT 84043 IlpdnteAddrnsand return a"Mark mason for e8anpa. eu, •taemn, Address " Renewal ❑EmPleymaot [I East Card � t P' Massachusetts - DO) r#ment of Public Safety Board of 6110dina Regulations and Staindards '-Icense: CS-108068 r KYLE GREENE 44 MAIN STREET North Reading MA 018" s " >r Expiration �' Conin tss ones 01/2012018 J� ('► RESIDENTIAL SOLAR POWER PURCHASE AGREEMENT �1/l�l►//�rfj'Jryte JOI�C Customer Name and Contact Information: Transaction Date �Gf GG uY uY Y Name(s) Robert Camire service No.2016-11-28 Installation Location Address 10 Francis Rd Approximate Start and 10 Francis Rd Salem MA 01970 Completion Date Salem Home Phone 5083310379 2017-05-27 MA 01970 Cell Phone 5083310379 E-Mail robertcamire@comcast.net Our Promises + We will design,install,maintain,repair, + We will not place a lien on Your Property. monitor,and insure the System at no additional cost to You. - + You are free to cancel this Agreement any time prior to Our commencement of + We warranty all of Our work,and that Our installation work at Your Property. roof penetrations will be watertight,for the initial 20 year term. + The Energy Price includes a$5 monthly discount for paying by automatic debit + Your Energy Price will not increase by more from Your bank account. than 2.9%per year. + You will not be responsible for any + After five years,if You need to make property tax assessed on the System. Property repairs,We will remove and + We will fix or pay for any damage We may reinstall the System if You pay Our estimated costs. cause to Your Property or belongings. Your Commitment ' Pay for the Energy produced by the System. • Maintain a broadband internet connection. • Keep Your roof in good condition throughout • Continue service with Your Utility for any the Term. energy used above and beyond the System's production. • Respond to Our sales and support teams when scheduling and completing paperwork. At the End of Your Initial Term ' You can renew the Agreement • You can request that We remove the System for a subsequent term; at no additional cost. • You can purchase the System;or If You Move ' We guarantee You can transfer the • You can relocate the System to Your Agreement to the new owner,regardless of. new home;or credit rating; • After the sixth anniversary,You can purchase You can prepay the Agreement; the System. Vivint Solar Developer, LLC(EIN: 80-0756438)is a licensed contractor in each state in which we operate,for information about our contractor licenses please visit www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN &OPT-OUT NOTICE BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: support@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 84043 Phone 8T7.404.4129 I Fax 801.765.5758 Copyright©2016 Vivint Solar Developer,LLC All Rights Reserved PPA(8/2016,v3.2.2)1 Page 1 Yam , SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. INCORPORATED DOCUMENTS. These documents G. You have the right to require Us to have a are incorporated into this Agreement and apply to the performance and payment bond. relationship between You and Us: (1) Residential Solar H. CUSTOMER'S RIGHT TO CANCEL. YOU MAY Power Purchase Agreement, (2) Exhibit A: Notice of CANCEL THIS CONTRACT AT ANY TIME BEFORE THE Cancellation, (3) Exhibit B: State Notices and LATER OF: (1) MIDNIGHT OF THE THIRD (3RD) Disclosures, (4) Exhibit C: Certificates of Insurance, BUSINESS DAY AFTER THE TRANSACTION DATE, OR and (5) Customer Packet. (II) THE START OF INSTALLATION OF THE SYSTEM OR B. WE HAVE NOT GUARANTEED, PROMISED OR ANY OTHER WORK WE PERFORM ON YOUR OTHERWISE REPRESENTED ANY REDUCTION IN PROPERTY. IF YOU WISH TO CANCEL THIS CONTRACT, ELECTRICITY COSTS IN RELATION TO THE SYSTEM YOU MUST EITHER: (1) SEND A SIGNED AND DATED THAT WILL BE INSTALLED ON YOUR PROPERTY. WRITTEN NOTICE OF CANCELLATION BY MAIL, E-MAIL, C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES OR FAX; OR (2) PERSONALLY DELIVER A SIGNED AND UNLAWFULLY OR COMMIT ANY BREACH OF THE DATED WRITTEN NOTICE OF CANCELLATION TO: PEACE TO REMOVE GOODS INSTALLED UNDER THIS VIVINT SOLAR DEVELOPER, LLC, 1800 W ASHTON AGREEMENT. BLVD, LEHI, UT 84043, ATTN: PROCESSING D. DO NOT SIGN THIS AGREEMENT BEFORE YOU DEPARTMENT. IF YOU CANCEL THIS CONTRACT HAVE READ ALL OF ITS PAGES. You acknowledge that WITHIN SUCH PERIOD, YOU ARE ENTITLED TO A FULL You have read and received a legible copy of this REFUND OF YOUR MONEY. REFUNDS MUST BE MADE Agreement, that We have signed the Agreement, and WITHIN 10 DAYS OF OUR RECEIPT OF THE that You have read and received a legible copy of every CANCELLATION NOTICE. SEE THE ATTACHED NOTICE document that We have signed during the OF CANCELLATION FOR AN EXPLANATION OF THIS negotiation. RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO YOU THE "NOTICE OF CANCELLATION". A SALES REPRESENTATIVE. I. Unless You are provided with a longer period in F. DO NOT SIGN THIS AGREEMENT IF THIS Exhibit A,You may not terminate this Agreement after AGREEMENT CONTAINS ANY BLANK SPACES. You are three(3) business days of the Transaction Date. If You entitled to a completely filled in copy of this seek to cancel thereafter, then You will forfeit any Agreement, signed by both You and Us, before any amounts previously paid and You may owe Us the work may be started. Default Payment. VIVINT SOLAR DEVELOPER, LLC CUSTOMER(S): Signature: Signature:Printed Name.: Serge Dldenko Printed Name: Robert+ Canpmlre Salesperson No.: Date: 2016-11-28 Date: 2016-11-28 Signature: Printed Name: Date 2016-11-28 Copyright© 2016 Vivint Solar Developer, LLC. All Rights Reserved. PPA(812016,v82.2)I Page 18 EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 5345375 Street Address Line 1: Street Address Line 2: City: State: Zip: Country: System Info Module Manufacturer: JA Solar Module Model: JAP6-60-270l4BB Module Quantity: 14 Array Size (DC watts): 3780.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: v.SE3800-US (240V) Project Design Variables Module Weight:40.124084lbs Module Length: 64.960665 in Module Width: 39.0157691 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 1.5 Exposure Category: B Importance Factor: I Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load-Lateral: 288 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar , Plane Calculations (ASCE 7-10): West Roof Roof Shape: Edge and Corner Dimension: 3.3382828150038904 ft Attachment Type: Composition Shingle- ES Flashing Stagger Attachments: Yes Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 33.3828281500389 ft Include North Row Extensions: No Roof Slope: 12.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 28.5 28.5 28.5 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 28.5 28.5 28.5 psf Downslope: Load Combination 3 6.3 6.3 6.3 psf Down: Load Combination 3 29.5 29.5 29.5 psf Down: Load Combination 5 11.8 11.8 11.8 psf Down: Load Combination 6a 29.9 29.9 29.9 psf Up: Load Combination 7 -10.3 -17.8 -27.4 psf Down Max 29.9 29.9 29.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 60.1 60.1 60.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.0 20.0 20.0 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 46.6 46.6 46.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.5 15.5 15.5 in EcolibriunnSolar -Layout a e r b Y I Skirt e Coupling ® End Coupling Note: If the total width of a continuous array exceeds 35 ft, break ® Clamp array to allow for thermal expansion and contraction. See ® End Clamp Installation Guide for details. ® North Row Extension Warning: PV Modules may need to be shifted with respect to roof 0 Row-to-Row Bonding Clip I Bonding Jumper trusses to comply with maximum allowable overhang. EcolibriurnSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 14 Weight of Modules: 562 Ibs Weight of Mounting System: 70 Ibs Total Plane Weight: 632 Ibs Total Plane Array Area: 246 ft2 Distributed Weight: 2.56 psf Number of Attachments: 35 Weight per Attachment Point: 18 Ibs Roof Design Variables Design Load -Downward: 918 Ibf Design Load -Upward: 720 Ibf Design Load -Downslope: 460 Ibf Design Load -Lateral: 252 Ibf EcolibriumSolar Bill Of Materials Part Name Quantity ES10260 EcoX Row-to-Row Bonding Clip 5 ES10121 EcoX Coupling Assembly 9 ES10146 EcoX End Coupling 3 ES10103 EcoX Clamp Assembly 25 ES10136 EcoX End Clamp Assembly 10 ES10144 EcoX Junction Box Bracket 1 (Optional) ES10132 EcoX Power Accessory Bracket 14 ES10333 PV Cable Clip 70 ES10334 4 PV Cable Clip 28 ES10195 EcoX Base, Comp Shingle 35 ES10197 EcoX Flashing, Comp Shingle 35 VoVe nt solar 1800 W Ashton Blvd. Structural Group Lehi, LIT 84043 Jon P. Ward, SE, PE Clint C. Karren, PE Structural Engineering Manager Structural Engineering Manager ion.ward@vivintsolar.com clinLkarren@vivintsolar.com November 30, 2016 Mr. Dan Rock, Project Manager Vivint Solar 1800 W Ashton Blvd. Lehi, UT 84043 Re: Structural Engineering Services Camire Residence 10 Francis Rd, Salem, MA S-5345375; MA-01 Dear Mr. Rock: Pursuant to your request,we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a representative from our office under my supervision identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof section is composed of 2x6 dimensional lumber at 16"on center and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 12 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B, Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page l of yoyont, solar B. Loading Criteria 8 PSF= Dead Load (roofing/framing) 40 PSF= Ground Snow Load 3 PSF= Dead Load (solar panels/mounting hardware) Total Dead Load= 11 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Root Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (www.ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 1W thick and mounted 4 Yz" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 11Y, is less than the maximum allowable per connection and therefore is adequate. 4. Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four (4) spaces or 64" o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. AA�I OF A Regards, N P G � Jon P. Ward, SE, PE AR MA License No. 52584 No 525 � gFGIVE C\+60 ss/ONAL - '•Pop t V0 Page 2of2 vivi t. solar N EXISTING PV SYSTEM SIZE: Q PLUMBING 5.53 kW DC VENTIsI ROLE VCR,, EASTING SDWR �ON ON GATEd pm S? DISH a V,o 0 NEW NC DISCONNECT - - — I LLIT 1A W ZZ tt CHIMNEY UG PV SYSTEM SIZE IB NEW INVERTER g o a 3.780 kW DC 2A EXISTING NC DISCONNECT in PB EXISTING INVERTER sKnlcrvT \'' NIN GSH,JADB, MODULES ❑ BW:5,ImCdN,PB m W THE I ACK Of EWH MODULE I O ® 'smDGac MODULES JV OF V FAC CONDUIT FROM NCTON BOX TO ELECTRICAL PANEL j rn PV INTERCONNECTION PLANT,INVERTER I I 3LOCKABLEDICCONNECTSWIFUL& _ _ _ UT. M IETERLOCATON;TEINTG C M O ETERX 25Ma12A c ❑M I N GTONBO%ATLAVRED TDMM USING MOUNTING CAMEL KEEP w �C TO CTION BOX OFF EDGE ❑ � E �- - __ I I Q S2 . $ Roof Type:COMP SHINGLE >j OR�of�SectiHIDsn 1 I i � I 0 ROMTL;iA I I I I I I I � �' I I i I a Ga = = W � LL. C) ' SHEET I I NAME: jEL Z R 4A 1B 1A I SHEET 2 M NUMBER: O L__—_—_—_—_—_____—_—_—_—_—_____— __—_—I PV SYSTEM SITE PLAN SCALE:114"=1'-0" a s CLAMP+ATTACHMENT COUPLING CLAMPASSEMBLY (INCLUDES GLIDER) LEAF SPRING dpmh w° GLIDER MODULE CLAMP+ATTACHMENT ¢ 9w = gLL ¢ PERMITTED COUPLING CLAMP SPACING I i RAFTER STRUT NUT ECOX BASE SEALING WASHER RAFTER FLASHING COMP SHINGLES L t f5 L=PORTRAIT MODULE CLAMP SPACING i I N Z V) g 5/16"x4 1/2" SS LAG SCREW IL=LANDSCAPE CLAMP SPACING TORQUE=1332 FT-LBS MODULES IN PORTRAIT LANDSPACE ays.o N0T�O5`"`E MOUNT DETAIL - ECOX z WITH METAL FLASHING w3.0 N°TTow.N= A z MOUNTING PV 3.0 DETAIL CANTILEVER L/3 OR LESS ; 6 N3 L=MAX 64" COUPLING CLAMP - R PV MODULES,TYP.MOUNT —�� 19 OF COMP SHINGLE ROOF, / MODULE SHEET PARALLEL TO ROOF PLANE H- Z JQ RAFTER Q M PV ARRAY TYP. ELEVATION SHEET NOT TO E NUMBER'. (3)PV SYSTEM MOUNTING DETAIL o NOTTO STALE N w 3.0 � a Photovoltaic S stem Conduit Conductor Schedule)ALL CO NDUCTORS MUST BE COPPER) .t 2 _. DC System Size Wire 3280 Tag if Description W Gauge OF of Conductors/color Conduit Type Conduit Size « AC System Size 3800 1PV Wire IOAWG 2(W,V-) N/A-Free Air N/A-Free Air Go to Total Module Count 14 1 Bare Copper Ground(EGC/GEC) 6AWG 18ARE N/A Free Air N/A-Free Airto o o 2 THWN-2 lOAWG 2(1V+,1V-)8/R PVC 1" to an,.. 4 2 2THWN-2-Ground 6AWG I(GRIN) PVC 1" a i 9coe. 3 TMWN-2 30 AWG 3(1L1,11.2,iN)B/R/W PVC 1" E a e 3 THWN-2-Ground 8AWG 1(GRN) DEC 1" p Ewining Inverter mbrmano^' to 4THWN-2 6AWG 3)1L1,1L2,IN)B/R/W LFNC 11. a Type'.I.Oin,1 us 4 THAN-2-Ground 8AWG 1(GRN) LFNC 1" Op g` FOOn nB Motlule l nformation: O Type'.IKM26SP-60 coun:22 SPEC/ANSI METER VISIBLELOCKAbc MIL0ANK 100A OR 'KmFE'A/C VA EQUILENT U5934- 015CONNECT NL-BLG SIEMENSWF222fl = 6ENS MF2 UNFUSED NEMA3 to OR EQUIVALENT M a vt Do Solar Edge 00 .vOn mgwxu5 Point of Interconnection,Supply Side F Up 'Conform b ANSI 70512(A).Conforms to NEC 2014 con C32.18008 j ^ SQUARE D DU222RR SQUARE D D222NRB Z W 240V/60A UNFUSED 240V/SOA FUSED NEMA3 w w N _ NEMN OR EQUIVPIFNT Oq EQU1VAIENT WITI JS Q Q V m WITq 75-C CTERMINODONS r ^ TEPMINAPON$ sal Z Z a M un V V' _ Exl1111g24OW125A SHEET Service Panel,Single NAME: Phave,with 100A Main as, Disconnect to Ilk. 0 STRING LI4 PV 1 2 \ 20A q MODULES 3 T C 3 SHEET 49 Minimum GECslze6 NUMBER: AWG copper 14PV MODULES PER ISTVERTEq=3JBO WATI2 —11 5 IWAK DIS1.1JULDIPURELE'KNIFE-V s„E Disconnect mSCONNECT IN SIGHT OF TAP W OC Safery Switch Conductor Calculations Rated for max operating condition of inverter PV Module Rating @STC -Wire gauge calculated from NEC code 330.15(B)(16)with ambient temperature calculations NEC 690.35 compliant Module Make Model JAPE-60-2]04BB/ / from NEC 310.15(2)(a). v ap o 'opens all ungrounded conductors m o Max Power-Point Current(Imp) 8.65 Amps For"On Roof"conductors we use the 90°C column ampaciry,0.5"-3.5"off-[he-roof temperature Optimizer Solar Edge P300 Max Power PointVoltage(Viral 31.23 Volts adjustment from 310.16(B)(3l(c),and raceway till adjustments from 310.15(B)(161. 2 i m Open-Circuit Voltage(Voc) 38.48 Volts For"Off Roof'conductors we use the]5°C column ampaciry,or the 90°C column ampaciN with p, w o DC Input Power 300 Watts the relevant ambient temperature and racewayfill adjustments,whichever is less. DC Max Input Voltage 48 Volts Short-Circuit Current(Isc) 9.26 Amps r Max Series Fuse(OCPD) 15 Amps The rating of the conductorafter adjustments MUST be greaterthan,orequal to,the to .. DC Max Input Current 12.5 Amps tlury upreted output current. Nom.Maximum Power at STC(Pmaxl 270 Watts DC Max Output Current 15 Amps Calculation Example-Wire Rating(90'C)x Ambient Temperature Adjustment xConduit Fill Max String Rating 5250 A Maximum System Voltage DC 1000V(UL) Adjustment>=Continuous Duty Output Current Inverter Make/Model SE38D Vbe Temperature Coefficient -0.33 %/C (On Reef,Tag 1):10gauge wire ratedfor40A, 40Ax0.76xl(2Conduaom)=30.4A>=18.75 CEC Efficiency 98 A AC Operating Voltage 246 PV Modu le Rating @STC (Off Roof,Tag 3):10gaugewire hatedtor35 A, 35A>=19J9A Continuous Max Output Current 16 Module Make/Model 1KM265P-60 L DC Maximummout Current 13 Max Power-Point Current(imp) R." Amps 0 Short Circuit Current 3].5 Max Power-Point Voltage(Viral 31.4 Volts H Max Output Fault Current 17.5 Open-Circuit Voitage(VOC) 38b Volts Short-Circuit Current llscl 9,03 Amps 49 Max Series Fuse(OCPD) 15 Amps ,o Optimizer Solar EdAAmp, Nom.Maximum Power at STC(Pmax) 265 Watts c DC Input Power 300 Maximum System Voltage 1000V DC(IEC) DC Max Input Voltage 48 Voc Temperature Coefficient -0.31 %/C rip DC Max Input Current 12.5 DC Max Output Current 15 Max String Rating 5250 AC Output Current According to NEC 690.8IB)(I1 15.83 Amps Nominal AC Voltage 240 Volts Inverter Make/Model SE2600A-US THIS PANEL IS FED BY MULTIPLE SOURCES——. AND SOLAR) OCPD Calculations ¢ AC Operating 9zs % ROOFTOP CONDUCTORAMPACITIES DESIGNED IN COMPLIANCE $ AC Operating Voltage 232 Volts WITH NEC 690.8,TABLE5310.15(B)(2)(a),330.15(B)(3)(a), Breakers sized according to continuous tlury output current.PV circuit nominal current based off cp Continuous Max Output Current 32 Amps 330.15(B)(3)(c),310.15(B)(16l,CHAPTER 9 TABLE 4,5,&9. inverter continuous output current%(1.25(NEC code 210.19(A)(1)(a)). g m DC Maximum Input Current 23 Amps LOCATION SPECIFIC TEMPERATURE OBTAINED FROM ASHRAE 2013 ON Short Circuit Current 40 Amps DATA TABLES. Inverter l:SE3800 A-US-U Max Output=15,83 A 1.25(NEC code 210.19(A)(1)(a)) i m m Max Output Fault Current 40 A/20ms ASHRAE 2013- =19J9q<20AIOCPD) > i m Highest Monthly 2%DB Design Temp:32.5 Celsius system output current w/continuous duty=19.79<20A(System OCPD) z N Lowest Min.Mean Extreme DB:-23.9 Celsiusir F r = n in Other Notes z _z f N •ALL INTERIOR RACEWAYS CARRYING DC CURRENT SHALL BE METALLIC SHEET •All ampaciN calculations are made in compliance with NEC 220.5(B) NAME: CI Y sir Z 6 SHEET NUMBER: N W Inverter Grounded Systems Per 690.5 C Main Service Panel Slgnage o �• Qnsta lied on the Face of the Serve Meter) m no Per 69054,690.56(Bf &705.10 •- -N1111 • • •u • •- Note:RooFline piward not needed unless PV disconnect is not as the E o Y Q ¢ D@Disconnect Per 690.53 — Combmer Boxes,J-Boxes,Disconnects Devices,& -• - - _ Inverters In Un-Grounded Systems Per 690.35(F) • • )I • ,• :i to jig I I 4' V y •Cend uitand Racewas Labeled Ever 10'') yp /I' 1T" • . V! N ACDisconnect and Any Load Centers,ICombinet Panel) • DG Disconnect Per 690.19 Inverter Output Eonneclion(Solar Breaker)at H ^ Main Service Panel Per 705.12 i w � j o w w m r Rapid Shutdown Per 690.56(C) Rap id Shutdown Disconnect Pen SW.12I5)Installed On AC Disconnect • • • SHEET • NAME: m c c w t `m a m 33ri SHEET NUMBER: ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY s•1 SHALL CONTAIN NO SMALLER THAN 318"WHITE ARIA FONT TEXT AND HAVE A RED BACKGROUND ui IC SYSTEM UAL POWER SOURCE I WARNING WARNING 1 CAUTION:S Property ofRVivirc SolarCONNE TED 4 SECOND SOURCE 15 A PHOTOVOLTAIC SYSTEM 9 ELECTRICAL SHOCK HAZARD 12 ELECTRICAL SHOCK HAZARD MAIN BREAKER OE-RATED TO"'"DUE TO SOLAR _ RATED AC OUTPUT:...A IF A GROUND FAULT IS INDICATED, "' THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE CIRCUITS NOM.OPERATING AC VOLTAGE:•"•V NORMALLY GROUNDED CONDUCTORS UNGROUNDED AND MAY BE ENERGIZED c m 2 MAX OF•••AMPS PV SOURCE ALLOWED Property of Vivint Solar MAY BE UNGROUNDED AND ENERGIZED Property of Vivint Solar , a . � n DO NOT INCREASE MAIN BREAKER RATING WARNING:PHOTOVOLTAIC POWER SOURCE Property of Vivint Solar SITE PLAN PLACARD SHOWING ADDITIONAL POWER E d4 Property of Vivin[Solar 5 Property of Vivint Solar WARNING 13 SOURCE AND DISCONNECT LOCATIONS.PLACARD 3 WARNING PHOTOVOLTAICACDISCONNECT 10 INVERTER OUTPUT CONNEC ION SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL w r ELECTRICAL SHOCK HAZARD RATED AC OUTPUT CURRENT:'••A DO NOT RELOCATE THIS OVERCURRENT DEVICE PANEL(only when necessary) DO NOT TOUCH TERMINALS.TERMINALS ON BOTH 6 NOM.OPERATING AC VOLTAGE:" V Property of Vivint Solar Property of Vivint Solar THE LINE AND LOAD SIDES MAYBE ENERGIZED IN Property of Vivint Solar PHOTOVOLTAIC POWER SOURCE DC DISCON N ECT A PHOTOVOLTAIC RAPID SHUTDOWN THE OPEN POSITION PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID 11 RATED MAXIMUM POWER POINT CURRENT(IMP) ...A 14 DISCONNECT Property of Vivint Solar 7 SHUTDOWN RATED MAXIMUM POWER POINT CURRENT(VMPj ...A "-"� Property of Vivint Solar PropertVof Vivint Solar MAXIMUM SYSTEM VOLTAGE(VOC) ''•V L PHOTOVOLTAIC DC DISCONNECT SHORT CIRCUIT CURRENT HSC) ...A (6 8 Property of Vivint Solar Property of Vivint Solar 0 ^`-value calculated for each N account,for specific value see the previous wa ruing label page 11 14 4 7 ROOFTOP AR RAY 8 12 6 6 6 2 4 13 IF APPLICABLE EVERY 11y AND WITHIN V_0_F ELBOWS 5 -- POLggyo 3 9 5 3 5 `3, 5 5 _3 5 1 5 1 ? 0 iz ac p.9 ! MICYSTEM RTER SYSTEM i w SS DC O DISCONNECT F a m INSIDE z_ z � m SHEET NSIBIE/LOCKABLE VIVINT SOLAR METER VISIBIE/LOCKABLE" SUB PANEL MAIN SERVICE 12 SOLAR INVERTERS COMBINER PANEL _ _ JUNCTION MAY BE ON ROOFTOP. (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT WHEN REEUIRED) DISCONNECT PANEL NAME STRING:INVERTER BOX 5 INTEGRATED WITH (WHERE REEUIRED) M SYSTEMS ARRAY) TYPICAL SOIA_R GENERATION iNSTALIATiQN 10 INSIDE PANEL 10 E a m (NOTALL DEVICESARE REQUIRED IN EVERY JURISDICTION) "" 3 rS n SHEET NUMBER: ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT,ENCLOSURES,RACE-WAYS,CABLE ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM,MARKINGS SMALLER THAN 3/8'WHITE ARIAL FONT TEXT,AND HAVE A RED SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 MM),WITHIN 1 FT(305MM)OF TURNS OR BENDS AND WITHIN 1 FT(305 MM),ABOVE a BACKGROUND AND BELOW PENETRATIONS OF ROFF/CEILING ASSEMBLIES,WALLS OR BARRIERS LIJ