Loading...
5 CRESCENT DR - BUILDING PERMIT APP 2. The Commfflgp fb s t S ,a ern Board of Building Regulations and an�xtt's CITY OF t ;tj SALEM y. Massachusetts St uildint_r Code, 780 CMR I�WOCT P � Revised;t/ar20/l Building Permit Application To onstruct, epair, n a e Or Demolish a ^ One-or Two-Family Dwelling (U This Section For Official Use Only Q Building Permit Number: Date pplied: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION I.1. Property Address: 1.2 Assessors Map& Parcel Numbers 5 Crescent Dr. Lla Is[Iris an accepted street?yes no Map Number Parcel Number I— 1.3 Zoning Information: 1.4 Property Dimensions: `` Zoning District Proposed Use Lot,Area(sq f) Frontage(11) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.61 c.40.§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: _ Outside Flood Zone? Public❑ Private❑ Check if veslJ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Ricardo Melendez Salem, MA 01970 Name(Print) City,State,ZIP 5 Crescent Dr. beaverbills@comcast.net No.and Street - Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK''(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units I Other Specify: Solar Brief Description of Proposed Work'`: Install 6.51ew solar panels on roof.Will not exceed roof panel, but will add 6" to roof height. 25 panels total. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I. Building $ 1,680.00 I. Building Permit Fee: $ Indicate how fee is determined: �. Electrical $ 22,320.00 ❑ Standard City/Town Application Fee ❑Total Project Cost' (Item 6)x multiplier s 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: $ Check No. Check Amount: Cash Amount: 6. Total Project Cost: $ 24,000.00 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 103631 8/30/17 Gregg LaCasse License Number Expiration Date Name of CSL Bolder List CSI-Type(see below) U 20 Patterson Brook Rd. Unit 10 No.and Street Type Description U Unrestricted(Buildings up to 35.000 cu. It.) W.Wareham, MA 02576 R Restricted IR2 Family Dwelling City/Town. State.71P M Masonr y RC Rooting Coverin WS Window and Siding SF Solid Fuel Burning Appliances (508)291-0007 1 1 Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 170355 10/12/15 Tom Blumetti/Trinity Solar HIC Registration Number Expiration Date FIIC Company Name or HIC Registrant Name 20 Patterson Brook Rd. Unit 10 No.and Street Email address W.Wareham, MA 02576 (508)291-0007 City/Town,State,ZIP Telephone SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........1( No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1.as Owner of the subject property,hereby authorize Tom Blumetti to act on my behalf, in all matters relative to work authorized by this building permit application. Please see attached letter. 10/5/15 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Tom Blumetti 1015/15 Print Owner's or Authorized Agent's Name(Electronic Signature) Dale NOTES: I. An Owner who obtains a building permit to do his/her own work.or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program), will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.eov!oca Information on the Construction Supervisor License can be found at ww�v.-dus 2. When substantial work is planned,provide the information below: Total Floor area(sq.ft.) (including garage,finished basement/attics, decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" (3 Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President October 28, 2015 Salem Building Department Salem, MA Re: Solar Electric Panels Installation To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. The Solar Photovoltaic System installed at the residence of Ricardo Melendez, 5 Cresent Dr. Salem. MA is installed as per the Approved Plans from the Town, as per manufacturer's requirements-specifications, and is in compliance with all applicable laws, codes, and ordinances, and specifically, International Residential Code/ IRC 2009, 2014 NEC, and 2012 ICC Energy Code, and will perform as designed. Very truly yours, Optimize Engineering Co., LLC Richard B. Gordon, P.E. Massachusetts P.E. License No. 49993 CIVIL, MECHANICAL, & ELECTRICAL ENGINEERING `TH OFM,yS4 ' 4 1 RIOHARD e. J O GORDON m U MEOHA1'C p NO.49993 r0 P�'/STERE�� ""'OVAL Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President October 26,2015 Salem Building Dept. Salem, MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional framing 2x6 at 16" o.c.with 9'-9"span (horizontal rafter projection)between supports. This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project. 2. Roof Loading • 4.33 psf dead load (modules plus all mounting hardware) • 30 psf snow live load (50 psf ground snow live load reference) • 4.5 psf dead load roof materials • Exposure Category B, 115 mph wind uplift live load of 1 s (wind resists e) 3. Address of proposed installation: Residence of Ricardo Mel dez 5 Crescent Dr. Sa m Massachusetts This installation design is in general conformance to the manufacturer's specifications,and is in compliance with all applicable laws, codes, and ordinances, and specifically, International Residential Code/IRC 2009, 2014 NEC,and 2012 ICC Energy Code. The spacing and fastening of the Unirac mounting brackets is to have a maximum of 64"o.c.span along the rail between mounting brackets and secured using 5/16"x 3'h" length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min.2" penetration of lag bolt per bracket,which is adequate to resist all 115 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load. Penetration of anchors for modules mounted within 18"of ridge and edges of roof is to be a minimum of 3". Rails may be attached to either of two mounting holes in the L-feet. Mounting in the lower hole for a low profile, more aesthetically pleasing installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more.Slide the 3,8-inch mounting bolts into the footing bolt slots.The rails will be attached to the footings with the flange nuts. Very truly yours, Optimize Engineering Co., LLLC �. l p,&5 H OF rygJ'T61 Richard S.G rdon, . . Massachusetts P.E. License No.49993 o Ric HARD s. m U GORDON MECHANICAL y . � CIVIL, MECHANICAL,& ELECTRICAL ENGINEERING TF NO 99993 /STEREO FSS/ANAL Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President September 21,2015 Salem Building Dept. Salem, MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional framing 2x6 at 16"o.c.with 12'span(horizontal rafter projection)between supports. This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project after sister rafters with a 2x6 using(2)10d nails 1' o.c. Use of(2)Guard DogTm FMGDO02 screws is approved, or equal shear strength of approx. 120 lb, V o.c.at areas where little space is available only with remainder of member secured with (2)10d nails V o.c. If do not sister,then install a 2x4 @ 16"o.c. knee wall over an interior bearing wall to limit span of rafters between supports to 9'-9". 2. Roof Loading • 4.33 psf dead load (modules plus all mounting hardware) • 30 psf snow live load (50 psf ground snow live load reference) • 4.5 psf dead load roof materials • Exposure Category B, 115 mph wind uplift live load of 19.6 psf(wind resistance) 3. Address of proposed installation: Residence of Ricardo Melendez, 5 Crescent Dr.,Salem, Massachusetts This installation design is in general conformance to the manufacturer's specifications, and is in compliance with all applicable laws, codes, and ordinances,and specifically, International Residential Code/IRC 2009, 2011 NEC,and 2012 ICC Energy Code. The spacing and fastening of the Unirac mounting brackets is to have a maximum of 64" o.c.span along the rail between mounting brackets and secured using 5116"x 3 W, length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min. 2" penetration of lag bolt per bracket,which is adequate to resist all 115 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load. Penetration of anchors for modules mounted within 18" of ridge and edges of roof is to be a minimum of 3". Rails may be attached to either of two mounting holes in the L-feet Mounting in the lower hole for a low profile, more aesthetically pleasing installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more.Slide the 3/8-inch mounting bolts into the footing bolt slots.The rails will be attached to the footings with the flange nuts. Very truly yours, Optimize Engineering Co.l LLC Richard (J Massachusetts P.E.License No.49993 4.P�j,{OF MgSSgO CIVIL, MECHANICAL, &ELECTRICAL ENGINEERING o=s -YEN RIGHARD B. 1 GORDON � O V�ECHANICAL m U NO,49993 O � ISTE���O�GSIONA�� I SNAPNRACK SERIES 100 ON FLASHED L-FEET REVISION. FLASHED L-FEET ARE OPTIMIZED FOR QUICK AND ROBUST INSTALLATION ON STANDARD COMPOSITION SHINGLE ROOF SURFACES FOR OTHER ROOF TYPES STANDOFFS ARE RECOMMENDED a SNAPNRACK MODULE ATTACHMENT HARDWARE -SNAPNRACK STANDARD RAIL 777 ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD ' ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR j STRUCTURAL MEMBERS SUCH AS STEEL PURLINS) ROOF SHEATHING,UNDERLAYMENT,- AND ROOFING MATERIAL,TYR SNAPNRACK FUISHED L-FOOT- MANSTREAAI NERGr COMP .DESIGNER: GMCPIRetary IsE DNS PART NUM9EB (DESCRIPTION: REV srVa Wad- "°R DRAFTER DRyw SI00 DOt SERIES 1000VL-FEEW,ON FLASHED c PV HQU N® woe -- APPROVED er. oATe 120113 L-FEET r