Loading...
8 CIRCLE HILL RD - BUILDING PERMIT APP (002) l '7 2-0 3 C-K. -Loci The Commonwealth of Massachusetts F O Board of Building Regulations and Standards CITY ITY Massachusetts State Building Code,780 CMR SALEM Revised.Mar 201l Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applie ws. N mpg 3 Building Official(Print Name) Signature Date 1a7 SECTION l:SITE INFORMATION 1 Zn 1.1 Pro ert Addres : r— Y � ,l 1.2 Assessors Map& Parcel Numbers 50 L la Is this an accepted street?yes X 110 Map Number Parcel Number v � 1.3 Zoning Information: 1.4 Property Dimensions: < .CR1 Zoning District Proposed Use Lot Area(sq ft) Frontage(it) --J 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.O.1.c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check ifyes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Kevin Maher Salewi MA. Name(Print City,Slate,ZIP Circle Hill Rd. 781 -223-4294 Jgmaher@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK''(check all that apply) New Construction X I Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work: ROLO+DV n 1+4-IC— SolCLY— V—%o SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ l"1 -00 I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical S2� El Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $ 6.Total Project Cost: $ 2S Aa Check No. Check Amount: Cash Amount:_ a� 13 0 Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 6y-52514 ca 28 ]CL.wle's License Number Exp anon ate Name of CSL Holder List CSf.'I'ype(see below) U r ,R 1 kaly� S-rv'eP+' No.and Street Type Description Sea uc 1,(_S "l A 1 A ac( b 1 U Unrestricted(Buildin s u to 35,000 cu.ftJ � l w R Restricted 1&2 FamilyDwelling CitylTown,S %IP M Mason ry RC Roofing Covering -- WS Window and Siding _ �,." SF Solid Fuel Runn ng Appliances p- 14s13 U(pj AagioIa" VIVtt*cSfl) u. I Insulation Tele one Email address rn D Demolition 5.\2 'R,egistered Home Improvement Contractor(HIC) (�0�48 I 1 yll l\± Soj0r F"10Ve-jQpeY LLC- HIC Registration Number Epuaton ate H C . SODC q3NmHRgistrant Name Yv�GiSo1Gu�JvtvtvtFgolctr. No.and Street Email address (�rvt Provo LTl— S4tor)4 -1$1305301Q5 City/Town,Slate,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes --.....� No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize VI V 1 v-)�- S>,Icw- to act on my behalf,iQ all m s e1 tive to work authorized by this building permit application. QT`Oy�""_� 10/31/14 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in tK pl ' lion is true and accurate to the best of my knowledge and understanding. \11VIVItav- A IS-I(4 Print Orvr s r rued Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.rnass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage, finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" V e l solar 3301 North Thauksgir ing Way,Suite 500 Structural Group Lehi, UT84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering sco ft.wysslingCa vivintso tar.com October 29, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Maher Residence 8 Circle Hill Road, Salem MA S-4042801 5.865 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 16" on center with 1 x 8 collar ties every 32". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused b overstressed underlying members. 9 Y Stability Evaluation: abilit A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category 'B" and 22 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per (ASCE/SEI7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivi t. solar 4 y Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF= Live Load (ground snow load) • 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 11F with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64" o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, o=��tNOFSSgry� O� y y CfVI Scott E. Wyssl PE ° 'g MA License N . 50 9p� E�ISTEP� FSSION A- dodunt. solar U C m 0'OF 1"PVC CONDUIT JUNCTION BOX ATTACHED FROM JUNCTION BOX TO ELEC PANEL ��qW ARRAY USING ECO HARDWARE TO i¢f KEEP JUNCTION BOX OFF ROOF 01 ED �U a2 m 7 w0 VL/ I , PV SYSTEM SIZE: 5.865 kW DC I , 0 •� O 0 zM N K U Q 1 > M K > Z w U K K W J J W m Z i 3 f o N N J Q SHEET NAME: PV INTERCONNECTION POINT, (23)Yingli Energy YL255P-29b MODULES WITH A LOCKABLE DISCONNECT SWITCH, UJ Z Enghase M21560-2LLS2x-ZC MICRO-INVERTER ANSI METER LOCATION, MOUNTED ON THE BACK OF EACH MODULE &UTILITY METER LOCATION Jd SHEET NUMBER: 8 Circle Hill Rd , Salem MA 01970 PV SYSTEM SITE PLAN SCALE: 3/32"= V-0" > d n x i z m 8 0 ��o NC(U N�^ 80 O� go O'A C C T y N y ii 0 owNMI 0 N I WER A N o i A r O C C mu y Em T - v m zz o_ X 1 O m3 m O T Nm T1 'y A V r D Z C M D M INSTALLER:VIVINT SOLAR J{, 3m m INSTALLER NUMBER:1.877.404.Ot29 vayan1f so Maher Resll idence P\/ 2 p ROOF y MA LICENSE:MAHIC 170848 {� Salem,MA'01970 V PLAN DRAWNBY:CR$ JAR4042801 ILasl Motlifetl:l0/912014 UTILITY ACCOUNT NUMBER:75628-55008 EcolibriumSolar Layout Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with o Bonding Jumper maximum allowable overhang. EcolibriurnSolar Layout - _ Q Skirt e Coupling 0 Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with Bonding Jumper maximum allowable overhang.