Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
5 CARROLLTON ST - BUILDING INSPECTION
RECEIVED G� I► 1'ECTiONAL SERVICES The Commonwealth of Massachusetts 2814 OCI 2 pCI"Y�C ' 0 ._. r sWtt Board of Building Regulations and Standards � t4f Massachusetts State Building Code,780 CMR SALEM '1a;y.. - - Revised.49ar 2011 Building Pennit Application To Construct,Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applicd: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.2 Assessors Map&Parcel Numbers L I a is this an^accepted street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq to Frontage(11) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'ofRecord:Jesse WolkieWICZ Sottewl MA. Name(Print) City,Slate,ZIP 5 Carrollton St. 508-527-1576 Robinjess@comcast.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction t8(I Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ 1 Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Description of['roposed Work: O-FpV dlC. Sol0.r— � A p SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials I.Building $( ,co 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ a ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 33 tSOeYJ 0Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.11-Construction Supervisor License(CSL) ©LA-S:,,5 4 License Number Expo ation ate Name of CSL Holder Rt �kc6h S l r l l List CSL l ype(see below) U No.and Street 9ype Description SCL LDS A I Q IA O LP IJ Unrestricted(Buildin s u to 35,000 cu. (. _ �"l _I R Restricted I&2 Famil Dwellin City/Town,s • ;!IP M Masonry RC Roofing Covering WS Window and Siding "- US 1 US SF Solid Fuel Burning Appliances -1dI-J 11 /Y`Cotarp-VlulV�tru I InsulationTale hone Email address rn D Demolition 5.2 Registered Home Improvement Contractor(HIC) VL IV\'t' 50k0.1—D2V2tolDey, l—l�`s48 lt4 t/ ` L C HIC Registration Number E punt on Date HIC Company Name or HIC R gistranl Name �08 V�. W�GtSolGtr@VtvtvLA-solar No,and Street Email address GDrvl Provol?t- $t}IDOI} —I!?L O oLPS City/Town,State,ZIP Telcph..e SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .......... No...........❑ SECTION 79:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize VI V I✓tfi SD ICL.V' to act on my behalf, in all matters relative to work authorized by this building permit application. 10/18/14 Print Owner's Name(Electronic signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in i i p lion is true and accurate to the best of my knowledge and understanding. V' ate n ' l6 P-9 1q Print Ow s r rized Agent's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.niass.gov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage, finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths 'type of heating system Number of decks/porches Type of cooling system Enclosed Opal 3. "Total Project Square Footage"may be substituted for"Total Project Cost" A`R CERTIFICATE OF LIABILITY INSURANCE °1'0 nro2613v2013 """' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed_ If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACI MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PNC,N a No: DENVER,CO 80202-5534 E-MAIL ABn:Denver.mrbequess@MarsLoom,Fax 212-948.4381 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# 462738-STND-GAWUE-13-14 INSURER A:Evanston Insurance Company 35378 INSURED National Union Fre Insurance Co of PA Vivint Scar,Inc. INSURER S. 4931 N 300 W INSURER c:New Hampshire Insurance Company 23841 Provo,UT 84604 wsuRm D: WSURER E: INSURER F- COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL UBR POLICY NUMBER R WOCYEFF MMN LIMITS EXP LSI A GENERAL LIABILITY 13PKGWE00274 11101/2013 W0112014 EACH OCCURRENCE 5 1,000,000 DAMAGE TO X COMMERCIAL GENERAL LIABILITY PREMISES Ea ocm RFNTE ce $ 50,000 CLAIMS MACE M OCCUR MED E% (Any one person) $ 5,000 PERSONAL BAOV INJURY $ 1,000,000 GENERALAGGREGATE $ 2,000,000 GEN-L AGGREGATE OMIT APPLIES PER: PRODUCTS-COMP/OP AGG 8 2.000,000 X POLICY JFCT PR0. LOC S B AUTOMOBILE LABILm 9701087 11/01/2013 1V01/2014 COMBINED SINGLE UNIT 1,000,000 Ea acddent $ B X ANY AUTO 9701088 11/01/2013 11/0112014 BODILY INJURY(Parr person) Is ALL OW ary OWNED SCHEDULED BODILY INJURY aodd S X AUTOS AUTOS PROPERTY DAMAGE $ N HIREDAUTOSAUTOS Per acddem S A UMBRELLA L X OCCUR 13EFXWE00088 11101/2013 1110112014 EACH OCCURRENCE _$ 10,000,000 X UI6 EXCESS LAB CLAIMS-MADE AGGREGATE $ 10,000,000 OED I I RETENTIONS I $ C WORKERS COMPENSATION 029342334; 029342335 11101/2013 11/01/2014 X IWC STATU- OrH- C AND EMPLOYERS'LIABILITY YIN 029342336; 029342337 11/01/2013 11/01/2014 1,000,000 ANY PROPRIETORIPARTNER/EXECUTIVE NIA E.L.EACH ACCIDENT $ C OFFICERIMEMBER EXCLUDED? g2934yy� 11101/2013 itl01/2014 1,000,000 (Mandatory In INN) E.L.DISEASE-EA EMPLOYE S Ryas tlwaib und er der 1,000,000 DESCRIPTION OF OPERATIONS below E.L DISEASE-POUCY UNIT $ A Errers B Omissions& 13PKGW00029 11101/2013 11/01/2014 LIMIT 1,000,000 Contractors PolluBon DEDUCTIBLE 51000 DESCRIPTION OF OPERATIONS I L=MCNS I VEHICLES(Atbeh ACORD tat,AddlUanal Remadm Schedule,Wn apace b mwq dl e Cerdade Holder and others as defined in the written agreement are included as addidonal insured where required by written mnbacl with respect to General Uabilily.This insurance is primary and non- nbibutory over any ensfng insurm os,and limited M liability arising out of the operators of the named insured and where required by wri8en contract Waiver of subrogation is applicable where required by written ntrect with respect to General Liability and Wodrers Compensallon. CERTIFICATE HOLDER CANCELLATION Gfy of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Ina Kathleen M.Parsloe ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations _ 1 I Congress Street, Suite 100 Boston, iYl4 02114-2017 www.mass.gov/dia 'Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Le ibly Name (Business/Organization/Individual): Vivint Solar Developer LLC Address: 4931 North 300 West i:� Lilz:_ Provo. UT 84pC4 _Phone#: 801-704-9389 Are you an employer? Check the appropriate box: F Type of project(required): 1 1.❑X I am a employer with 10 4. ❑ I am a general contractor and [ 1 . ❑ New construction employees (full and/or part-time).* ,'.avr iier�';I ;tic vnh-�.nrt rands — - I ❑ Remodeling 2.❑ I am a sole proprietor or partner- !'�idU oil tht• .ttLtch,iJ sheet. 7.; � ship and have no employees har suh-W,rntr,tc �r, have I ' g ( 1 ❑ Demolition working for me in any capacity. empiuyecs ,wd Lave v orkers i [No workers' comp. insurance comp. insurance.t 9. ❑ Building addition i required.] 5. ❑ We are a corporation and its ! 10.0 Electrical repairs or additions 1 k 3.❑ I am a homeowner doing all work officers have exercised their i 11.❑ plumbing repairs or additions j myself. [No workers' comp. right of exemption per MGL i 1 insurance required.] t c. 152, §1(4),and we have no f, , 12.❑ Roof repairs employees. [No workers' i 13.0 Other comp. insurance required.] 'Any applicant that checks box#] must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such- #Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they most provide their workers'comp.policy number I am an employer that is providing workers'compensation rnsurancefor my employees. Below is the policy and job site information. Insurance Company Name:__ New Hampshire Insurance Company Policy#or Self-ins. Lic. #:_ 029342228 __ _ Expiration Date: 11/01/14 lob Site Address:_ ko� ( �_ _—_ City/State/Zip:2�i(U� -- Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine - of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under prrirn r d peliallie u%perpirt'r i the information provided above is true and correct trtu1.nc ,r. 301-70d-9389 Official use only. Do not write in this area,to be completed by city or town official � City or Town: Permit/License#_ i Issuing Authority(circle one): — — Il. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. plumbing Inspector 6.Other ,_- 1 Contact Person: phone#: i tom_ ._.._ _. ..- ---- iv t'arx riaza - quite -') b /u Boston, Nfassachusetts 02I I6 Dome Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC_ Expiration: 1/5/2016 JAUIES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card. Mark reason for change. sca o r amna. dev ❑ Address ❑ Renewal Employment Lost Card i Massachusetts -Department of Public Safety Board of Building Regulations and Standards Construction Supenisor '^ License: CS-045254 6 Eom Hollos? 14rfise SAUGtiS� 01 W Expiration ®�l2S/2O o5 commissioner r} i [.^v j 4931 North 300 West Structural Group Provo, U'r84604 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering Scott.wysslingC vivintsolar.com October 11, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Wolkiewicz Residence 5 Carrollton Street, Salem MA S-4018126 6.63 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of trusses for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal prepared identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 16"on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 30 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. .- Page 2of2 B. Loading Criteria • 10 PSF = Dead Load roofing/framing 40 PSF= Live Load (ground snow load) • 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2012 International Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing truss system will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and truss system show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 '/2" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than the panel length when installed parallel to the trusses (portrait). No panel supports spacing perpendicular to the trusses shall be greater than four (4) trusses or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2012 International Residential Code, current industry standards and practice, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, tN OF =S� E CyG , Scott E. Wyssli PE o 50 MA License No. 505 qoF 0 ISTS FSS/ONAI V � V �YYY• '. ai 5 Carrollton St, Salem MA 01970 U < � AS--- ----- ----- ------- I I Ninmw LL �m oQE (E&)ase Enemv YLPk2._ZC MODULES WITH A N QEi En MOO MOUNTED ON THE BACK MICRO-INVERTER d MOUNTED ON THE BACK OF EACH MODULE I I h O \----Pv INTERCONNECTION POINT, a LOCKABLE DISCONNECT SWITCH,I ANSI METER LOCATION, �_ &UTILITY METER LOCATION I I P'OF 1"PVC CONDUIT FROM JUNCTION BOX TO ELEC PANEL I _ JUNCTION BOX ATTACHED TO ARRAY USING ECO HARDWARE TO I T KEEP JUNCTION BOX OFF ROOF Y e O gmoe � Q N W U I I w Q � Z W W K K N ) J J Z m U � I 3 J Q SHEET PV SYSTEM SIZE: I NAME: 6.63 kW DC I H J cn ---------------------� SHEET NUMBER: PV SYSTEM SITE PLAN 4 SCALE: 1/8"= 1'-0" > a N� N� 080 on on p ac oc �j cy�` ro Jn TN ma �I N. N' NO N� 0 3 V ity N 0T NZ 2 m0 a Can m U) ra m � I m o � O O n r D z DiINSTALLER:VIVINTSOAR Wolkiewicz Residence P\/ 2.0 11mm y ROOF y C V MA LICENSE MAH C 170B484044129 • S5C arrMA olton St PLAN DRAWN BY:EF I AR 4018126 Last Modifie 10/9/2014 UTILITY ACCOUNT NUMBER:7565B40013 CLAMP C (M MOUNTING SEALING e PV3.0 DETAIL WASHER D •N LOWER �ymw SUPPORT w 01 U�d� PV MODULES, TYP. MOUNT " """" ""' 3"yo OF COMP SHINGLE ROOF, FLASHING Y i PARALLEL TO ROOF PLANE 2 1/2" MIN o 5/16"0 x 4 1/2" MINIMUM STAINLESS PV ARRAY TYP. ELEVATION STEEL LAG SCREW NOT TO SCALE TORQUE= 13±2 ft-Ibs 7 CLAMP ATTACHMENT NOT TO SCALE N CLAMP+ 8 ATTACHMENT CANTELEVER L14 OR LESS •c:3 COUPLING J L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT m COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. g N PERMITTED COUPLING g m c o CLAMP+ CLAMP CLAMP ATTACHMENT SPACING w T COUPLING PHOTOVOLTAIC MODULE > w w w z m F F w z 3 m m ¢ z z f o SHEET NAME: L=PORTRAIT CLAMP SPACING Z O ~ ECO 2 p COMPATIBLE SHEET L=LANDSCAPE MODULE PV SYSTEM MOUNTING DETAIL NUMBER'. CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE Inverter Ratings(Guide Section 4) O Conduit and Conductor Schedule Inverter MakelMMel Enphase Mgt 560-2LLS2aZC Tag Oes.,bou Wtre Gauge pal Conduri CmEnt Tons I Conduit So. W MODULE DETAIL Max oc vdt Rose, 45 V.I. V Max Power @40'C 215 Wefls 1 EnPM1ase engage w0le-THWN-2 12 AWG p Cwtl WA-Free Al, �m Nominal AC Vocable 2A0 Vasa 1 said Copper Grouts IEGGGEC) 6AWG I N/A-Free Air WA-free Air C Yingli Energy YL255P-29b Max At Curren! as Amps a a 2 THWN-2 tO AWG 6 PVC V-1' SOLAR MODULE Max xi 120 Amps � uO1, Max Numher of Panelai it p 2 THWN-2-Ground eAWG I PVC V-1' oc - 3 THAN BAWG 3 PVC (i /1 NOTES FOR INVERTER CIRCUITS(Guide Section S and 9), eAWG PVC 0'-t' a)/ "-W 3 THWN-2-Ground I ca 1.)IF UTILITY REQUIRES AVISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings @ STC(Guide Section 5) r Enphase M215-60-2LLS2x-ZC SWITCH MEET THE REQUIREMENTS] z Model Maxeloodel Yingli Energy YL255P-29b IV L EACH MODULE ATTARATCHED YES NO XNA UU mz EACH MODULE,ATTACHED Max Power-Point Conant 9mp) 0.32 Amps WITH ECO HARDWARE 2.)IF GENERATION METER REQUIRED,DOES THIS METER M11ae power-Point VoOege(Vmp) 30.fi Volts -j rOwO SOCKET MEET THE REQUIREMENTS? OpenCirwit vo0age(Ya) 38.7 Volts 9 //111 U YES NO XNA mart-Circuit Current(Ise) BBB Amps ya Q 3)SIZE PHOTOVOLTAIC POWER SOURCE(OC)CONDUCTORS h1.Sense Fuse(OCPI) 1 15 Am, Y BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STC(Pmax) 1 2551 Wafts MICROINVERTER CONNECTION RATING AT DISCONNECT. Maxmum System Voltage 1000(IECy600(UL) Q TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vac Temperature Co0lfsient TO INVERTER OCPD AMPERE RATING(Sam Guide Section 9). > 5.)TOTALOF 2 INVERTER OCPD(s).ONE FCR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix On PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1 J Lowest expected ambient temperature based on ASHRAE minimum mean extreme p6 BARE CU GROUND NEC 690.64(8)(2)(a)? AYES NO dry bulb temperature for ASHRAE location most similar to insfellation location: -19'C ' (GROUNDING ARRAY) Signs(See Guide Section 7) 2)Highest continuous ambient temperature based an ASHRAE highest month 2%dry bulb temperature for ASHRAE location most similar to installation lowticn'. 39-C r r� Sign for inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47-C in the Solar PV System AC Point of Connection United States(Palm Springs,CA is 44.1'C).For less than 9 cunent-carrying conductors i t in roof-mounted sunlit conduit at bast 05"some mof and using the outdoor design AC Output Current 23.400000 Amps temperature of 47-C or less(all of United States). _ • Nominal AC Voltage 14UI Volts a)12 AWG,901 conductors are generally acceptable for modules with Ise of 7.68 Amps •Y� or less when protected by a 12-Amp or smaller fuse. THIS PANEL FED BY MULTIPLE SOURCES to b)10 AWG,90-C conductms are generally acceptable for modules with 1.of 9.6 Amps (UTILITY AND SOLAR) o or less when protectedb a i 5-Amps or smaller fuse. �G NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY o ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR Oil J an PV CIRCUIT 1: 13 MODULES/PARALLEL ENVOY BOX cam m ¢ ad a — g � oe l/'�fWP O - � K y an as = Q I I Z as a --✓x _.r --�, E 1.o MURRAY POINT OF DELIVERY > i w w COMBINER AND INTERCONNECTION Im c PANEL 125A/240V SIEMENS LWO04NR 6DAr240V OR EQUIVALENT UNFUSED NEMA3 PV CIRCUIT 2: 13 MODULESIPARALLEL �\fT6L SREC/ANSI LNF222R ORSHEE \ EQUIVALENT Osal, METER NAME: \moo EXISTING 2 13 • • • O O i \P zap 240V/200A W Q LOAD-CENTER Z Q _ M Q .7` • • • s s � \ 30A p SHEET ______A__ ___�__ _ _______ ____ 631 _____ NUMBERMILBANK VISIBLE/LOCKABLEJUNCTION BO% 2 \\ 3 100AOR 'KNIFE'A/CNEC 2014 Com liant WITH IRREVERSIBLE E 1 0 \ EQUIVALENT DISCONNECP GROUND SPLICE E 1.0 U5934-XL-BLG E 1.0 W Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Jesse Wolkiewicz Project Address: S Carrollton St,Salem MA A.System Description: The array consists of a 6.63 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(26) 255-watt modules and (26)215-watt micro-inverters,mounted on the back of each PV module.The array includes (2) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar. B. Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting Svstem: A.System Description: 1. Roof type: Comp. Shingle 2.Method and Type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2. For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrium Solar b.Product Name: Ecorall c.Total Weight of PV Modules and mounting hardware: 1094.8 Ibs d.Total number of attachment points: 46 c.Weight per attachment point. 23.8 Ibs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 457.18 square feet h. Array pounds per square foot: 2.39 Ibs square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (26)modules,(46)attachments 23.8 pounds Vivant. 5,o'c i r 3. Electrical Components: A.Module (UL 1703 Listed) Qty Yingli Lnergy YL255P-29b 26 modules Module Specs Pmax-nominal maximum power at STC - 255 watts - Vmp-rated voltage at maximum power - 30 volts Vac-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Ise-rate short circuit current - 9.01 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21,I-S22 26 inverters Inverter Specs, 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 13 modules/inverters (15) amp breaker PV circuit 2 - 13 modules/invetters (15) amp breaker 2011 NEC Article 705.60(B) vivint. D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 11.7 amps Continuous current adjustment factor 125% 2011 NEC Articic 705.60(B) PV circuit continuous current rating 14.625 amps 2. Overcurrent protection device rating PV circuit continuous current rating 14.625 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed V above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (t40.72-F) 71% 2011 NEC Article 705.60(B) Adjusted PV circuit continuous current 20.5 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 25.7 amps Total derated ampacity for PV circuit 25.7 amps Conductors(tag2 on 1-line)must be rated for a minimum of 25.7 amps THWN-2(90°C) 414AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Article 705.60(B) 4.Voltage drop (keep below 3%total) 2parts 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1. Mirco-inverter voltage drop: 0.15% The largest number of micro-inverters in a row in the entire array is 7 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.15%. 2.AC conductor voltage drop: =I x R x D (=240 x 100 to convert to percent) = (Nominal current of largest circuit)x (Resistance of#14AWG copper) x (Total wire run) = (Circuit 1 nominal current is 11.7 amps) x(0.00319Q) x(84') (240 volts)x(100) 1.3% Total system voltage drop: 1.45% vivint. s C)- :-i r EcolibriumSolar Customer Info Name: 4018126 Email: Phone: Project Info Identifier: 13069 Street Address Line 1: 5 Carrollton St Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity: 26 Array Size (DC watts): 6630.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 40.8 Ibs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 110.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load - Upward: 820 Ibf Lag Bolt Design Load - Lateral: 300 Ibf EcoX Design Load - Downward:493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load -Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-10): 1 EcolibriumSolar Roof Type: Composition Shingle Average Roof Height: 30.0 ft Least Horizontal Dimension: 17.0 ft Roof Slope: 30.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.73 0.73 0.73 Roof Snow Load 24.5 24.5 24.5 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 1 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 24.5 24.5 24.5 psf Downslope: Load Combination 3 11.8 11.8 11.8 psf Down: Load Combination 3 20.4 20.4 20.4 psf Down: Load Combination 5 13.6 13.6 13.6 psf Down: Load Combination 6a 24.5 24.5 24.5 psf Up: Load Combination 7 -11.2 -13.4 -13.4 psf Down Max 24.5 24.5 24.5 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 66.3 66.3 66.3 in Max Spacing Between Attachments With RafterfTruss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 22.1 22.1 22.1 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 44.5 44.5 44.5 in Max Spacing Between Attachments With RafterfTruss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.8 14.8 14.8 in Layout EcolibriumSolar �r! � ®tr �=�: m: ram.. � c � �- _ervo-� —�• [tilt'. Skirt C3 Coupling 0 Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with I r l �:.• W— �- of{CE —Dr• L:; • e 8. ego l Bonding • a• Distributed Weight (All Planes) EcolibriumSolar In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1061 Ibs Weight of Mounting System: 92 Ibs Total System Weight: 1153 Ibs Total Array Area: 458 ft2 Distributed Weight: 2.52 psf Number of Attachments: 46 Weight per Attachment Point: 25 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 46 ECO-001_102 EcoX Coupling Assembly 37 ECO-001_105B EcoX Landscape Skirt Kit 0 ECO-001 105A EcoX Portrait Skirt Kit 5 ECO-001_103 EcoX Composition Attachment Kit 46 ECO-001_109 EcoX Electrical Assembly 1 ECO-001_106 EcoX Bonding Jumper Assembly 3 ECO-001_104 EcoX Inverter Bracket Assembly 26 ECO-001 338 EcoX Connector Bracket 26 Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Pro'ect Information I Project Name: Jesse Wolkiewicz Project Address: 5 Carrollton St,Salem MA A. System Description: The array consists of a 6.63 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(26) 255-watt modules and(26)215-watt micro-inverters,mounted on the back of each PV module.The array includes (2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Eeolibrium Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind.Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp. Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2. For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecollbrlum Solar b.Product Name: Ecorall c.Total Weight of PV Modules and mounting hardware: 1094.8 Ibs d.Total number of attachment points: 46 e.Weight per attachment point: 23.8 Ibs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 457.18 square feet h. Array pounds per square foot: 2.39 Ibs/square foot i. Distributed weight of PV array on roof sections: -Roof section 1: (26)modules,(46)attachments 23.8 pounds vivin4. , . . 3. Electrical Components: A. Module (UL 1703 Listed) Qty Yingli Energy YL255P-29b 26 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Isc-rate short circuit current - 9.01 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21:.1.S22 26 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max. DC short circuit current - 15 amps Max. input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 13 modules inverters 15 breaker ( ) amp PV circuit 2 - 13 modules/inverters (15) amp breaker 2011 NEC Article 705.60(B) D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 11.7 amps Continuous current adjustment factor 125% 2011 NEC Nmde 705.60(B) PV circuit continuous current rating 14.625 amps 2.Overcurrent protection device rating PV circuit continuous current rating 14.625 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Amde 705.60(B) Adjusted PV circuit continuous current 20.5 amps c.PV Circuit current adjustment for conduit fill Number of current carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 25.7 amps Total derated ampacity for PV circuit 25.7 amps Conductors(tag2 on 1-line)must be rated for a minimuun of 25.7 amps THWN-2 (90°C) #14AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Arude 705.60(13) 4.Voltage drop(keep below 3%total) 2 'arts: 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1. Niirco-inverter voltage drop: 0.15% The largest number of micro-inverters in a row in the entire array is 7 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.15%. 2.AC conductor voltage drop: = I x R x D (=240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#14AWG copper) x (Total wire run) _ (Circuit 1 nominal current is 11.7 amps) x(0.003192) x(84� -(240 volts)x (100) 1.3% Total system voltage drop: 1.45% vivint. .:.C)' : EcolibriumSolar Customer Info Name: 4018126 Email: Phone: Project Info Identifier: 13069 Street Address Line 1: 5 Carrollton St Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity: 26 Array Size (DC watts): 6630.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 40.8 Ibs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 110.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load - Upward: 820 Ibf Lag Bolt Design Load - Lateral: 300 Ibf EcoX Design Load - Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-10): 1 EcolibriumSolar Roof Type: Composition Shingle Average Roof Height: 30.0 ft Least Horizontal Dimension: 17.0 ft Roof Slope: 30.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.73 0.73 0.73 Roof Snow Load 24.5 24.5 24.5 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 24.5 24.5 24.5 psf Downslope: Load Combination 3 11.8 11.8 11.8 psf Down: Load Combination 3 20.4 20.4 20.4 psf Down: Load Combination 5 13.6 13.6 13.6 psf Down: Load Combination 6a 24.5 24.5 24.5 psf Up: Load Combination 7 -11.2 -13.4 -13.4 psf Down Max 24.5 24.5 24.5 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 66.3 66.3 66.3 in Max Spacing Between Attachments With Rafter(rruss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 22.1 22.1 22.1 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 44.5 44.5 44.5 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.8 14.8 14.8 in Layout EcolibriumSolar Skirt e, t f f F I i I � I q I . ,..�. ..,..:.. .®. . , . ...was,_ ,.,.. . �. .:,.- �• ::.. 8._ .. ,.�..-- "" Coupling 0 Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with Bonding Jumper maximum allowable Distributed Weight (All Planes) EcolibriumSolar In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1061 Ibs Weight of Mounting System: 92 Ibs Total System Weight: 1153 Ibs Total Array Area: 458 ft2 Distributed Weight: 2.52 psf Number of Attachments: 46 Weight per Attachment Point: 25 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 46 ECO-001_102 EcoX Coupling Assembly 37 ECO-001_105B EcoX Landscape Skirt Kit 0 ECO-001 105A EcoX Portrait Skirt Kit 5 ECO-001_103 EcoX Composition Attachment Kit 46 ECO-001_109 EcoX Electrical Assembly 1 ECO-001_106 EcoX Bonding Jumper Assembly 3 ECO-001_104 EcoX Inverter Bracket Assembly 26 ECO-001 338 EcoX Connector Bracket 26