Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
72 BUENA VISTA AVE - BPA-2005-329
City of Salem `"aid X WMIr t ApOUGATION I FOR PERMIT TO BUILD ADDITION, MAKEALTERATIONS OR NEIAI.CONSTRUCTION IMPORTANT-Applicant to cOM016tO aN items in sections. 4 i4 i►b IV, and OC p [W1. Al&OCTtow. Z bV .✓ Frot ATMN (_� AND BETw®1 ttLDING SUMOSION LOT_BL= TYPE AND COST OF BUILDING-AN applicants conlP>e A-� A. TYPE OF IMPROVEMENT D. PROPOS1.ED USE.FOR-DEMOUTIOW USE MOST REGENT USE . .. MoawuOarrYr 1 rMwq 13 Q InReapa.a taranrir 2 Q AddM*n r ffl3dw W'rWmff"W CW 12Pq OfMrY 1943 OftatL o3rr R+9ae wmw anga0e4 Y amK n prt0.121 13'0'Two orm fw*-Gev nr~ 2D J3 1n0-06Y1. :... 3 ❑ ANwwon OW 2 aorel �J T r rasa 21 QT'', P�q 9XW rre'sa MOK noel or Oono9rY• M G sU "-swo .uors9ro9s • Q Rraareuraorrers 1X lEo rarrarerv.'o 23 jala.o+rt:resret s Q nmeq.wp wrert.rr.ner - of ur 0s L Org n PM 0.131 t3 ❑ C++w9s 24 ¢,09ba tar+tolorm ar 23.Q.Pt 1F s Q m0 mwmvv N - 13 0 Crort oLw - .. 7D;Q,9drowa4 fEratYover. ..aofenr 7 Q FaNmn oral 17 ❑ OVr•SOso1Y _ 27^Q sMre...erar+l. a.OwNERSWP 23© Trills.toms 3 Ubirid,r.CdDri00M1nrt0i0• 29 Q-oarw-$vw* .,rA�itlOriwG 9 a Putoc rF@090L SOL a bCy 9oownea . . { . . NWW84" D-000 it d0a Pwo—o tea al llrpuBa,a9.lo0s wow-"A" !€S[[ C.COST tOrrr arrw marJrire ereo.IaurOry our0+9 r trospaoL eerrerary sonoot rnrwr7srinal ooss9s. f _ POW",. t9.lroor:Orlurg.gara9r br Oa0a1'irrsrX awe.mnWWM bAd 091or Ousting rtr N 10. Cnorovamst—. -- S I ��f L�K"' r.a.uorMsaL�wea.emringa.car„gy#//osr9a111°�r/aJ'�°p0u'OuM' To pF Out not amkided :tra�os� �/•1 p I - tt ftwom C/C� t lttarq v MuNirr9 v3pf3RwAFWdC1 TofPvRovEmE+aParts.EED CHARACTER15f1CS 9'BUJNG For new buildings and additims comP>ese on Parts J$M,aN others skiptoN1'YP.,EnF FYtA11E 'F.-'PRNC9�TYPE OF iEA791fi Fi)ELL G. TYPE SEWAGE DISPOSAL L TYPE OF MECRAWCAL qD. .P+Bfaareri+sbeonerq WEVr Oe Dramtr 30 �., .wd k �� 3s pi s1 Prirea"EPIC WYt�Ja � IS Q No caar�mw 37 Q E3aos.+Y K TYPE OF WATER SUPPLY %w*w*oYrrrr�AFWd C1 a c+ d -scrdY 42 0F0R4ftCaW4ww 4 0 Y48 NO 34.© OMW-sac* 43:0 Pnwft*mkast�+M _� -; J.DIMENSIONS - °s NY11p""WMS M _DEMOLITION OF STRUCTURES: 49. Twz snore ee d Bmr arcs a:agora o a asao m senor .' . Hal;,Approval from Historical COmmiswm been received al for airy stnx;ture over fifty(50)years? Yes_ No- 50. Taaluw area aua r:' Sate Number IC NUMBER OF OFF.MEET PARxmG SppCES ft 51. ErcJmeo Pest C0*01: F 52 Oraamq 7 VE I HE FOLLOWING UTILITIES BEEN DISCONNECTED? "m _T t av4 ' %orrrs Yes No ilea. .. . 53 Erclaaae • .,:. Bec4ic St;_1MoDara n11 .. : . .. Sewer: �1 { Par" DFIMENTATION FOR THE ABOVE MUST BE ATTACHED BE'OREA PERMIT CAN BE•ISSUED:�y ; IV COMPLETE THE FOLLOWVr H'Isiono District? Ye a-_ No (If Yes pleaseencloseAopua>e p-trsm:HIsL'CamW Conservation Area? Yes_ No_ (If Yes;please enc� se of Condrfora) Has Fve PreventiEhn approved and swnped Plans or wticatme Y Is Property located in fhe SR.A disirkt? Comply wlph Z~ No_ (M rho enc�ose BaapdoLgppeal decison) Is lot grand►atlher t7:;yey `_ No (M yes,submit documer donlF no,submit Board of Appeal decision) M'new conspucu figs"prow Routing Slip been enclosad? _ Is Architechval I Access Board approval required? Yee`_ No= (M Yes,submit doamhentadon) Massachusetts state CmIractor License t S BLv PAS SNem License eJ'�`I7Sc� w .. +k he hnprovBmenl Corhtraator aK L3'4 Y�" ►or rs. Exempt form(d appFc") yes_ Mo C6NSMLIC770N.T0 BE.COMMENCED WITHNSIX 16)MONTHS OF ISSUANCE OF BUILDING PERMIT CONSTRUCTION IS TO 8E COMPLETED BY: ' f°` Man extension is ,Please subttlft in writing 10 Iheln PecADr'itY i V. IDENTIFICATION• To be completed by all applicants i Neaa Mrgamm•Ak~.Seca. aew ZIP coo TILNm i Aid N ?bY to the rR isa#xhraedty ate er own of record and oo llhaveeen b autihor¢ed by the ownerb make ersappication ed aae we! ro conlorrlT�paE,aopkcade taws of 1flis jurisdiction. r r " DO NOT WRITE BELOW THIS LINE VI. VALIDATION Building Permit number FORTEp USE ONy Bu Permliissued use Gmup � f9_ -Budding Are cra*V Pemi t Fee $ LiYs lo.o;p Cerbfic ate Of Occupancy APProved by O=cszy Load Drams Tk $ � 1 Plan Review Fee a titer TTILE NOTES AND Data•(Fa department usg) PERMIT TO BE MAILED To- DATE MAILED: Corftuftn tO be started by. Cwoleted by x i i VI ZONING PLAN EXAMINERS NOTES , 01$TRICT � USE FRONT YARD SIDE YARD SIDE YARD REAR YARD i NOTES 1 SITE OR PLOT PLAN•For ApplicsM�� . i ' - I i YO ON I SEP-03-2004 09 :31 AM P. 02 LOT 2 43,495 S.F.{ PROP. WELL RE rrZ DENNIS J. w MCMANUS �cAj m� b 5A.31' PLOT PLAN IN sALEM, MA FOR HOWARD A. SQUIRES BUENA VISTA AVENUE (WEST) p17E.• 9/03/04 SGILE 1' = 40' .AG9. ALD O4O4t THE FOUNDATION ON THIS PLAN IS LOCATED O,,-E ,� SHOWN. D10GOV LANDMARK RU B dNG my cwsrnwr smat DENNIS l MCMANUS, P.L.S. M AM01� YHAP q i La� q� CITY OF SALEM ROUTING SLIP CHECKED DEPARTMENTS REQUIRE SIGNATURES BEFORE BUILDING PERMIT WILL BE ISSUED. LOCATION: ' dY V C' DATE: 1 !� APPLICANT: PJ IL � t/ Eg- ASSESSORS OFFICE @ 93 WASHINGTON ST. FRANK KULIK . DATE: CITY CLERK(if involving a new street) @93 WASHINGTON ST. DEBBIE BURKINSHAW DATE: PUBLIC SERVICES(Engineering Dept.) Qal/c7 •a4- o �9 q �s � @120 WASHINGTON ST.4TH FL. / BRUCE THIBODEAUfe9e NQ b { pTE; l fA f� El WATER DEPT. / SQ @120 WASHINGTON ST,4TH FL. HELEN JIADOSZ i/D�AJT'E:_'9-/6 D y CJ CROSS CONNECT SUP'R BOB DESCHENE @120 WASHINGTON ST,30.D FL. DATE: PLANNING @120 WASHINGTON ST.,3 FL..� 0Hiii6@*6*iliiiE V IA DATE: VaM,040 0a1N(T7..J.' CONSERVATION CONMSSION (Planning ept.) @120 WASHINGTON ST.,3,-F 1 DATE 9 ao/G F ank 1z", » 1 h a Y Cj ELECTRICAL @ 48 LAFAYETfE STREET,2ND FLEAR JOHN GIARDI tl f �� u�DATE: FIRE PREVENTION @29 FORT AVE(WILLOWS AREA) J / �� CAPT.HUDSON �/ DATE: 2/ 4/iJ� HEALTH @120 WASHINGTON ST.,4TH FL JOANNE SCOTT 6o DATE: w BUILDING DEPT @ 120 WASHINGTON ST.._0.5 FL. TOM ST. PIERRE DATE: ***SUBMIT\ANTI PERNflT APPLICATION WHEN COTAP1 FTED*** . a n Permit Number REScheck Compliance Certificate Checked By/Date Massachusetts Energy Code REScheckSoftware Version 3.5 Release le Data filename: G:\2004.00\2004.06 Norman-Miano\Norman-Minano Energy Calcs.cck PROJECT TITLE:Norman-Miano Residence { CITY: Salem STATE: Massachusetts HDD: 6268 CONSTRUCTION TYPE: 1 or 2 Family,Detached HEATING SYSTEM TYPE:Other(Non-Electric Resistance) DATE: 05/10/04 DATE OF PLANS:May 10,2004 PROJECT DESCRIPTION: Norman-Miano Residence,Single Family Detached _J DESIGNER/CONTRACTOR: Dean Associates Architects Incorporated James W.Dean,AIA PROJECT NOTES: New construction of a one family home with attached in-law suite, approx.3,645 finished square feet. 4 bedrooms,2 1/2 baths in main home, 1 bedroom and 1 bath in in-law suite. COMPLIANCE:Passes Maximum UA=614 Your Home UA=588 4.2%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Floor 1:All-Wood Joist/Truss, Over Unconditioned Space 2178 30,0 0.0 72 Ceiling 1:Flat Ceiling or Scissor Truss 1468 30.0 0.0 51 Ceiling 2: Flat Ceiling or Scissor Truss 713 30.0 0.0 25 Wall 1: Wood Frame, 16"o.c. 3700 13.0 0.0 250 Window: TW2646: Wood Frame,Double Pane with Low-E 279 0.280 78 Window: TW3046: Wood Frame,Double Pane with Low-E 211 0.280 59 Window:TW2046:Wood Frame,Double Pane with Low-E 21 0.280 6 Window:TW2632: Wood Frame,Double Pane with Low-E 18 0.280 5 Window:DHP1062: Wood Frame,Double Pane with Low-E 14 0.280 4 Window: DHP1046: Wood Frame,Double Pane with Low-E 10 0.280 3 Exterior Door: Solid 100 0,350 35 Furnace 1:Forced Hot Air,78 AFUE Air conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the Massachusetts Energy Code requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. The heating load for this building,and the cooling load if appropriate,has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Builder/Designer ,, 60 Date <166 G RMheck Inspection Checklist Massachusetts Energy Code REScheckSoftware Version 3.5 Release le DATE:05/10/04 PROJECT TITLE:Norman-Miano Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: Windows: [ ] I. Window:TW2646: Wood Frame,Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments:Andersen 400 Tilt Wash [ ] 2. Window:TW3046: Wood Frame,Double Pane with Low-E,U-factor: 0.280 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ }Yes[ ]No Comments:Andersen 400 Tilt Wash [ ] 3. Window: TW2046: Wood Frame,Double Pane with Low-E,U-factor: 0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ] Yes[ ]No Comments: Andersen 400 Tilt Wash [ ] 4. Window: TW2632: Wood Frame,Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments:Andersen 400 Tilt Wash [ ] 5. Window:DHP1062: Wood Frame,Double Pane with Low-E,U-factor: 0.280 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break?[ ]Yes[ ]No Comments: Andersen 400 Picture [ ] 6. Window: DHP1046: Wood Frame,Double Pane with Low-E,U-factor: 0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments:Andersen 400 Picture Doors: [ ] I 1. Exterior Door: Solid,U-factor: 0.350 Comments: Standard Steel Solid Exterior Door w, foam core I Floors: [ ] 1. Floor 1: All-Wood Joist/Truss,Over Unconditioned Space,R-30.0 cavity insulation Comments: I Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air,78 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] When installed in the building envelope,recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated,manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated,in accordance with Standard ASTM E 283,with no more than 2.0 cfin(0.944 L/s)air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs/ft2 pressure difference and shall be labeled. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts shall be insulated per Table J4.4.7.1. Duct Construction: [ ] All accessible joints, seams,and connections of supply and return ductwork located outside conditioned space,including stud bays or joist cavities/spaces used to transport air, shall be sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Heating and Cooling Equipment Sizing: [ ] Rated output capacity of the heating/cooling system is not greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Circulating Hot Water Systems: [ ] ( Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 120 T or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to I" _Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)