Loading...
22 BERTUCCIO AVE - BPA-11-140 SOLAR 1 Z (D (LIN The Commonwealth of Massachusetts I jw0 VA � ' Board of Building Regulations and Standards �a Massachusetts State Building Code, 780 CMR SALEM' e�vi`ezA r AI Building Permit Application To Construct, Repair, Renovate Or Demolish'jk'o A a One-or Two-Family Dwelling This Section For Offici Use Only (`t] Building Permit Number: Dat Applied: J1 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers f 2� E3 e r-r k-A c c I o py [� L la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: - 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal ❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1Cy e600aman Salem MA 01970 Name(Print) City, State,ZIP 22 Bertuccio ave 7819532295 Gooddrum@gmail.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New ConstructionA Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units I Other ❑ Specify: Brief Description of Proposed Work': I rlS-rQ' ( I GM O r—) QC— • E SECTION 4:.ESTIMATEL-, ^UC''t 7N c_'STS Item Estimated Costs: Official Use Only Labor and Materials 1. Building $—3 (, ,L- to- 1. Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $ 14 I Q S .'00 ❑ Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3. Plumbing $ - 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: $ Check No. Check Amount: Cash Amount: 6. Total Project Cost: $ ❑ Paid in Full ❑ Outstanding Balance Due: d SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) C 5---� l ZC)1118 I'Q '�{� Q-�_(Z) License Number Expiration Date Name of CSL Holder `� I List CSL Type(see below) Type Description No.and Street U Unrestricted(Buildings up to 35,000 cu.ft. R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) (--`Qgl I S z� V (V )Y-) 1 0 Y HIC Registration Number Expiration Date HiC Company Name or HIC R gistrant Name W SU rr k�1 2 - G71-Q Q1'1Q No.and Stree Email addressv� t�\ City/Town,State,ZIP Telephone J SECTION 6: WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L,c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of ke Issuance of the building permit. Signed Affidavit Attached? Yes ...... No ........... ❑ SECTION 7a: OWNEWAUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Viyint Solar to act on my behalf,in all ruLatters relative to,,w�or(k authorized by this building permit application. Cliff Goodman M ) -[ 0 4/8/16 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. III 111 �0 Print Owner's or Aut rized Agent's Name(Electronic Signature) Date NOTES: l. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIQ Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage, finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost!' ViAlm u e so l r 3301 North Thanksgiving Way, Suite 500 Structural Group Lehi, UT 84043 P: (801) 234-7050 Scott E. Wyssling, PE Senior Manager of Engineering scott.wyssling@vivintsolar.com April 04, 2016 Mr. Dan Rock, Project Manager Vivint Solar 3301 North Thanksgiving Way, Suite 500 Lehi, UT 84043 Re: Structural Engineering Services Goodman Residence 22 Bertuccio Ave, Salem MA S-4862197 8.06 kW Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof Sections (1 and 2): Roof section is composed of 2x10 dimensional lumber at 16" on center and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. • Roof Sections (3 and 4): Roof section is composed of 2x10 dimensional lumber at 16" on center with 1x8 collar ties every 48" and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 28 and 40 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B, Zone 2 per (ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page 2 of 2 B. Loading Criteria 10 PSF = Dead Load (roofing/framing) 40 PSF = Live Load (ground snow load) 3 PSF = Dead Load (solar panels/mountinq hardware) Total Dead Load= 13 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 '/2"thick and mounted 4 '/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the Nation Design Standards (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 '/;', is less than the maximum allowable per connection and therefore is adequate. 4. Roof Sections (1, 2, 3, and 4): Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four(4) spaces or 64"o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. AScotttE lyyours, jNOF, sc g �yL SLI4IL . Wyssling, P No.st507 MA License No. 5 7 g909`GISTS ae `cSS/ONAI EHC' a� U C a m m doh �¢mm Roof Section 3 <� RodAam&197 OMP.SHINGLE m fZ �" R7 Roof Section 4 "00 RWAAmulh:197 ¢ RoaTk 40 O O L PV STRING#2. V STRING#7: 15 MODULES ifi MODULES [/�J V PLUMBING VENT(S RT •G v •0 8 Roof Section 1 Roo(A imuth:107 Roof Tilt:28 m `o rn a gmo < o w W U m Q Z IY w Y N m W Z 07 � W INK Z 3 N Z z Q Qry 2 Q Roof Section 2 SHEET NAME: Roo 2 :287 RoofTkTiR 28 TIE INTO METER# t.L Z 37238094 O Ofa HIMNEV SHEET NUMBER: PV SYSTEM ROOF PLAN 4 N SCALE: 1/8" = 1'-0" > m U CLAMP C MOUNTING O SEALING -0 � PV3.0 DETAIL WASHER (n mom m w LOWER 08 1 SUPPORT z �m Ez cu�mo U PV MODULES, TYP. MOUNT OF COMP SHINGLE ROOF, FLASHING O Z PARALLEL TO ROOF PLANE L S/16"0 x 4 1/2" MINIMUM STAINLESS PV ARRAY TYP. ELEVATION STEEL LAG SCREW NOT TO SCALE TORQUE=13±2 fl-lbs CLAMP ATTACHMENT • NOT TO SCALE Cm N OC y- CANTELEVER L/4 OR LESS Oc= 8 COUPLING L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE N MODULE CLAMP SPACING. PERMITTED COUPLING m m m CLAMP m o a CLAMP p 7 rc SPACING COUPLING PHOTOVOLTAIC MODULE E z w .. w w z m � � w w w a z_ z_ � z L=PORTRAIT SHEET NAME: CLAMP SPACING F � Z ECO ::) H COMPATIBLE O W T L=LANDSCAPE MODULE PV SYSTEM MOUNTING DETAIL 2 0 CLAMP SPACING SHEET IMODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE NUMBER: NOT TO SCALE 0 \M Q Conduit and Conductor Schedule (ALL COPPER CONDUCTORS) DC Safety Switch No'il Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size Rated for max operating cons 1 Solar Edge Cable 10 AWG 2 (V+, V-) N/A- Free Air N/A- Free Air NEC 690.35 compliant 1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A- Free Air N/A- Free Air *opens all ungrounded condt 2 THWN-2 10 AWG 4 (V+, V-) PVC 1" 2 THWN-2 - Ground 8 AWG 1 PVC 1" 3 THWN-2 8 AWG 3 (1-1-1, 1-1-2, 1-N) PVC V Notes: 3 THWN-2 - Ground 8 AWG 1 PVC 11. Wire size and breaker calculatior inverter Continuous Maximum Oi Example: SE38000A-US-U Max OL <20A. Therefore a 20A solar brea each SE380OA-US-U inverter. Win be determined with 16A Max for ea ALL CONDUCTOR SHALL BE COPPEI RACEWAYS INSIDE DWELLING SHALL Design Conditions: ASHRAE 2013 Highest Monthly 2% DB Des 31 PV MODULES PER INVERTER =8060 WATTS STC Lowest Min. Mean Extreme 1 STRING OF 16 PV MODULES VOC Temp coefficient 1 STRING OF 15 PV MODULES System Specs: Max DC Voltage 0 0 0 ,6 1s Nominal DC Operating Volta 1 Max. DC Current per String Nominal AC Current -R7 O 0 0 0 F15 I SOLAREDGE 1 SE760OA-US-R + _ + _ INVERTER* i — _ — _ — o 0 0 _ _ — = M*O ��WAF,ETY a� U THIS ROOF SECTION'S TILT/AZIMUTH ARE C n UNABLE TO PRODUCE MIN 800 SUN HOURS v COMP.SHINGLE o 80om z =m d= ;• cc�.o ' U b. Q J ROOF SECTION Az:197 Ti:40 s t 3 MODULES@ 1162 SUNHOUR � r s� -ROOF SECTION 4 Az:197 Ti:40 3 MODULES @ 1177 SUNHOUR a IR N sG O A _N r h m m}} O Z M ¢ Qw _ ROOF SECTION 2 w w w m r Az:287 Ti:28 12 MODULES @ 855 SUNHOUR SHEET m NAME: QQ OOF SECTION 1 SHEET Az:107 Ti:28 NUMBER: 13 MODULES @ 1011 SUNHOUR SOLAR ACCESS'CONSTRAINT o 62.4%CUSTOMER USAGE OFFSET EcolibriumSolar Layout c c c Skirt c Coupling End Coupling Clamp 0 End Clamp Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal expansion and contraction. See Installation Guide for details. • North Row Extension Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Layout Skirt o Coupling End Coupling @o Clamp O End Clamp Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal expansion and contraction. See Installation Guide for details. • North Row Extension Warning: PV Modules may need to be shifted with respect to roof trusses to comply with Q Bonding Jumper maximum allowable overhang.