Loading...
54 BELLEVIEW AVE - BUILDING INSPECTION The Commonwealth of Massachusetts ' Board of Building Regulations and Standards CITY OF $ Massachusetts State Building Code,780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct, Repair,Renovate Or Demolish a 1 v One-or Two-Family Dwelling ' This Section For Official Use Onl Building Permit Number: I Date Applied: ' 4,,,Building Official(Print Name) Signature Date SECTION l:SITE INFORMATION LI Property Address: 2po` — 1.2 Assessors Map&Parcel Numbers 1.1 a Is this an accepted street?yes_ no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq R) Frontage(11) o 1.5 Building Setbacks(It) Front Yard Side Yards Rear Yard -o y r•t n Required Provided Required Provided Required Provided rn Z rn 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zane?Check if yes❑ Municipal❑ On site disposal systetQ;❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of RecorBarbara Marino Salem, MA. 01970 N Name(Print Ciry,State,ZIP 4 Belleview Ave 978-825-9098 Jbakmarino@hotmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ 1 Alteration(s) ❑ I Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work': } , �rl o nUh oa 1.�) - "Z. ECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ TO I. Building Permit Fee: $ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $ vl./ ❑Total Project Cost'(item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAQ $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ ��� Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ �' 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 0(-1ti25� 2�51 �P JGffuc, ShQy-"-L&y-) License Number Expiration Date Name of CSL Holder U EL:2� C/ 'e rt List CSL Type(see below) U No.and Street + lL/ �` Type Description aL XXA/VA r Y U O\gOLP U Unrestricted(Buildings up to 35,000 ca_ft.) R Restricted I&2 Family Dwelling City/Town,Stale,ZIP M Mason ry RC Roofing Covering WS Window and Siding �� C SF Solid Fuel Burning Appliances � -18)3DS DUS MaJUVAyaUAyiV1} LLAY cul I Insulation Telephone Email address D Demolition 5.2 Registered Im Home Improvement Contractor(HIC) V `V� `1 `t `ar HIC Registration Number Expiration Date HIC Co N me or BIIC�Registrant ist ant Name rqgy�� N hWW No.anQ-$tr�t� l,u U,` Sqw'A Email address City/Town,State,ZIP ` Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes..........❑ No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize V kOn t SU\.l1- to act on my beh If,in all matters relative to work authorized by this building permit application. t1t s oll/ r y� 04/09/15 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print Owner's or Authorized Agent' a(Elec nic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.eov,!oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total Floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage'may be substituted for"Total Project Cost" • The Commonwealth of Massachusetts Department of Industrial Accidents 1 — Office of Investigations "} I Congress Street,Suite 190 Boston,AM 02114-2017 r~ www.enass.gov/dla Workers' Compensation Insurance Affidavit: Bewilders/Contractors/Electricians/Plumbers Arplivant Inforneation Please Print Lezibly Name (Business/Organization/Individual): Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way, Suite 500 City/State/tip:Lehi, UT 84043 Phone #:801377-9111 Are you an employer?Check the appropriate box: 'Type of project(required): f.® I am a employer with 10 4. ❑ I am a general contractor and I employees(fu}1 and/or part-time).* have hired the sub-contractors 6. ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling shipand have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' insurance? 9. ❑ Build ng addition [No workers' pomp. insurancecomp. required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions ] 3.❑ 1 am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no 13.® Other Solar Installation employees. [No workers' camp. insurance required.] *Any applicant that checks box 41 most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then him outside contractors must submit a new affidavit indicating such. IContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins- Lic. #:WC 509601300 Expiration Date: 11/1/2015 + Job Site Address: vv City/State/Zip:_� r Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certfy under the pains and penalties of perjury that the information provider)ieJb/o��)ve is true and correct Sianature Date Phone#: 801-2296459 Official use only. Ito not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): I. Board of Health 2. Building Department 3. City/'Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person:. Phone#: �--� y, v..v..vv.vwvwvvo v v' �/ v vw,vrwvwwJ4'/ri'uJ Office of Consumer Affairs find Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2D16 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. SCA 1 0 20M-05111 Address ❑ Renewal Employment Lost Card ice! Massachusetts- Department of Public Safety Board of Building Regulations and Standards Construction Supen isor License: CS-045254 ! JAMES R SHER - 6 Fox Hollow Driiie SAUGUS MA 01506 ,r Expiration Commissioner 08/28/2016 CERTIFICATE OF LIABILITY INSURANCE 00/20Ma°"""" THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: N the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WANED,subject to the terms and conditions of the policy,Certain policies may require an endorsement A statement on this certificate does not Confer rights to the certificate holder in lieu of such endorsements). PRODUCER CONTACT MARSH USA INC. NAME: .._ 122517TH STREET,SUITE 1300 PHONE Fax Na.ExE lac No: DENVEft CO 80equest34 ACORILE . _ Attic OenvecceRrequest(gTmersh.mm,Fax:212.948.4381 -- -- INSURERS AFFORDING COVERAGE NAIC0 462738-STNDGAWUE-1415 INSURER A:Evanston Insurance Company 35378 INSUREDVivint Solar,Inc INSURER B:Conch American Insurance Company 16535 Vivint Solar Developer LLC INSURER C:American Zurich Insurance Company 40142 3301 North Thanksgiving Way Suite 500 INSURER D: Lehi,UT 84043 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-00236803N8 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. iN� TYPE OFINSURANCE ADDL SUDIR POUCYNUMBER POLICY EFF mPo"U XPV I LIMITS A GENERALLJABAJTY 14PKGWE00274 1110114014 11101)2015 EACH OCCURRENCE _ $ 1,0OD,00g X COMMERCIAL GENERAL LIABILITY P AI F-eon-RENuE6 nr $ r��0 CLAIMS-MADE OCCUR MEDEXP(An mre elsan) $ 5,000 X $5,000 Dad.81&PD PERSONAL&ACV INJURY $ 1,000.000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PROWCTS-COMPIOPAGG $ 2,000,000 POLICY X LOC $ B AUTOMOBILE LIABILITY BAP5096015DO 11101/2014 1110112015 COMBINED,SINGLE LIMIT BI 31 10000W X ANY AUTO BODILY INJURY(Per Person) It AALLOOtS^MED AIC�HOESOULED BODILY INJURY(Per acdden0 $ X HIREDA1:S X NOWNED PROPERTYAUTOS $ $ A UMBRELLA LIAR X OCCUR 14EFXINE000BB 11/0112014 11/01/2015 EACH OCCURRENCE S 5,000,000 X EXCESS LIAR CLAIMS-MADE AGGREGATE S 5,000,000 DED RETENTIONS $ C WORKERSCcMPENSATON WC509601300 11101f2014 1101i 15 WOSTATU- OTH- AND EMPLOYERS'UABILnY UWI B ANY PROPRIETORIPARTNER ECUTNE YIN WC509601400 1117)112014 11Ni12015 ELEACH ACCIDENTS 1,000,000 OFFICERIMEMBER EXCLUDED? rNI N I A (MandMary In Nei) E.L.DISEASE-EA EMPLOYE $ 1,D00,000 1!yea,dese lbe under DESCRIPTION OF OPERATIONS below EL.DISEASE-POLICY UNIT S 1,000,600 A Ermre&Omissions& 14PKGWEGD274 1110112014 11/01/2015 LIMIT 1,000,000 COnlroc10rs Pollution DEDUCTIBLE 5,GDO DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (AWO ACORD 101,AMMwnal Ramarb SzWule,R more rpce M requlndl The Certificate Holder and others as defined in Rewritten agreementam included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- contributory over any washing insurance and limited to liability arising oulof the operators of the named insured and where mquied by written contract Waiver of subrogation is appileahle where required by written conracl with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORMED REPRESENTATIVE of Mmeh USA Inc. I Kathleen M.Parsloe ./ r_T/t. JQIols'— 01988.2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD i I pr'i I f , C ' 0 0 pp V o l7' oni solar 3301 North Thanksgiving Way, Suite 500 Structural Group Lehi, LIT 84043 P: (801)234-7050 Scott E. Wyssling, PE Head of structural Engineering scott.wyssling@vivintsolar.com March 31,2015 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Marino Residence 54 Belleview Ave, Salem MA S-4218384 8.75 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2x6 dimensional lumber at 16" on center with 2x8 collar ties every 48". The attic space is unfinished and the photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 24 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per(ASCE/SEI7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivi t. solar i Page 2 of 2 B. Loading Criteria 10 PSF = Dead Load roofing/framing 40 PSF= Live Load (ground snow load) 5 PSF = Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 '/;' thick and mounted 4 '/" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher that 6" above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2', is less than the maximum allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 /i' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts will be adequate with a sufficient factor of safety. 4. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 5. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code, current industry standards and practice, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. SN OF V rUly yOUfS, _�� E cy�' CIVI n Scott E.Wyssli PE 0,50 MA License No. 505 90F FGISTEPE F6slo >_ vivi t. solar - "I �n rM 4931 North 100 West,Provo,UT 84604 Employer Identification No.: 80-0756438 i ( �t�'■ ■�. so l a r Phone:(877)404-4129 Fax:(901)765.5758 Massachusetts HIC License No.: 170848 1 E-Mail: sutsolaravrvmtsularcom w-Mail: inlsolaccom AR No.: RESIDENTIAL POWER PURCHASE AGREEMENT This RLSIDErN I AL POWER PURCHASE AGREEMENT(this"Agreemeni')is entered into by slid benecen VIVINT SOLAR DEVELOPER. LLC,a Uelanars limi0.xl liahiliy compam I"11'e'"."l.'.i "Our'1;tad Ihe wulersigneJ Gnnorner6a)I"Puri',")'our'),as ufdro'frausaction Loeser Ibrth below. { Ful I Name(re,.,.vt GuJ I„ a Full Name(ran,Us..m,u Cuslnmer(s): �'1 I'ticphone No.: IS-Mail: n 1V1Q - �.{'1 Properly Street Address: �� (� Address: Cil v.County,State.Zip: I.SERVICES A. DESIGN AND IN'SI'ALLA'1'ION. We will design,n,mall,sell it maintain a solar photovoltaic system on four Property,which will include all snlnr panel.inverters,maces.mW other componcurs(collectively.Ihe'.S,'onx"L as further described in the Customer Packet and the Work Order that We ;II l n uA I r Yr u h r 'Incr. All nr Ind p onion I I Ili Sv ncm will he nrSta k I by(hu unplo}ul rodmiLian.,and devil icnua+.and not.ubwnmmturx, With tour c ur arati n We call (d J spur install and coureo the System in m.nerial cmnplum e oath all applicable lase 00souiplea, ill required uuLwtti,in.:an�Un)obtain nil vqulred cen1lmations and permits. In order to design a System that meets four needs,You agree hot We may ubiniu Your eleetnczl mace hi tory Gam 1'nur electne utility(the 'Vhhn/' and You shall Pro%&Lis with copies of Your Until) hills as We may remmnahly request. Other[hall Ilia activation liv described in S,etion 1_B.We will design;atd iustall the System a st o,Y,ua. B. ACTIVATION. You agree to pay Us a one-time activation fee in the amount of S We ovill imcmomwet the System wish the Urlihv.and cause the System to generate energgyy measured in kilowatt hours ("kWh"))(it" "Energl• ). nsm11u1 ion ..I Ilrc System generally takes one day and Is anticipated to begin and be substantr'ally complete between two(2)and six(6)weeks hereafter. C. OWNERSHIP OF SYSTEM. We shall own the System as Our sole personal property You will have no property interest in the System. D. OPERATIONS AND MAINTENANCE. We will operate and maintain the System(i)at Our sale cost and expense;(ii)in good condition;and(iii)in material compliance with all applicable laws mid permits and the Utility's requirements. E. INSURANCE. We carry commercial general liability insurance,workers'compensation insurance,and property insurance on the System. For more information concerning Our insurance,and to obtain a copy of Our certificate of insurance,please visit: www.vrvmtsolar.co vinsurance. 2.TERM,PRICE,PAYMENTS,AND FINANCIAL DISCLOSURES A. ENERGY PRICE. For all Energy produced by the Svstem.You shall pad'Us$0, per kWh(The"Energy Price'),plus applicable taxes. The Energy Price shall increase each year by two and nine tenths Percent(2 9/a). A goo an esumate of the System output,measured inkilowatt hours, will be rovidcd to You in the Customer Packet. THIS AGREEMENT IS FOR HF SALE OF ENERGY BY US TO YOU AND NOT FOR THE SALE OF A SOLAR ENERGY DEVICE. B. TERM. This Agreement shall be effective as of the Transaction Date and continue until the twentieth(20')anniversary of(he In-Service Date(the "Term"), The"In-Service Date'shall be the first day after all of the following have been achieved (i)the System has been installed and is capable of generating Energy,(it)all permits necessary to operate the System have been obtained,(In)the System has been interconnected with the Utility,and(Iv)all in pections and certificates required under applicable law or by the Utility have been completed or received. C. PAYMENTS. Beginning with the first month following the In-Service Date and throughout the Term,We will send You an invoice rellecting the charges for Energy produced by the System in the previous month. You shall make monthly payments to Us by automata payyment deduction from Yam designated chocking account or credit card. It is Your responsibility to ensure that there are adequate funds or adequate credit limit. There is no financingg charge associated with this Agreement. For all ppayments more than ten(10)days past due,We may impose a late charge equal to l wenry-Five Dollars S25) and interest at an annual rate often percent(10%L plus applicable taxes. If Von continue to fail to make any payment within ten(10)days after We give You written notice,then We may exercise all remedms avarlable to Us pursuant to Section 13(b). D. RENEWAL. At tire cad of the'I'crin.You nnv elect to(i)confine x it),this Agreement on a year-tax-year basis:iii)corer into a new Acreenanl with Us and cancel this Aareemcm-(in)purchase the•S}51ent at the end d'the Tenn and cancel this Aerecntenl line'Purchase optia"'I' or(w)caned this Aercenrenl;rml have he Sy6mnr removed al no cost to%'on. You aill need to muiv Ids in writing concemrne Ynnr election sisn four days prior In tiro end of Ihe Fenn, If N'ou Act tire Purchase Option, Ihe Tunsmse Option Price' t11 he If,, ticn-currcnr f•,ir murkd uluc Sf the System Need on an indcpandcnt appmuer'.s vahlation of Similarly s¢cd phohrvoll:uc sYsrcms nr Your eeo¢raphic Lego un. "foe apppraiser:caluatinn wn11 he pnwuled to You In wriune and will be binding. II We receive Your payment of the Purchase.option Pricc,costs of the appraisal,applrrablc taxes,and all other amounts then oo nrg and unpaid hcreundI4,We will trunsle, w onership of tire System lax You at the end of the"term on an"As Is,W here IS basis. If Yoh.elect lax have the n Systn renamed.We will remove the tissma Frnrn Your lisle". wllI ninety 90)da s after the end of the Term. IF YOU DO NOT NOTIFY US OF \OUR ELECTION 'I'O CAN(El. 11), SF,N'DI:\G A NHI'fl'F.N NOTIC� TO US, THEN THIS AGREEMENT WILT. AUTOMATICALLY RENEW'ON A YEAR BASIS UNTIL YOU NOTIFY US IN WRITING OF YOUR ELECTION"1'0 CANCEL AT LEAST SIXTY(60) DAYS PRIOR TO THE END OF THE RENEWAL TERM. E. CREDIT CHECK. In connection with the execution of this Agreement and at any time during the Term,You herehy authorize Us to(i)obtain Your credit rating and re pon from credit reporting agqenenes; In) to report Your payment performance under this Agreement to credit reporting agencies;and (in)disclose this and other information to Our atHlmtes and actual or prospective lenders,financing parties,investors,insurers,and acquirers WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CIIOOSE TO STOP RECEIVING "PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE(SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3 LIMITED WARRANTY A. LIMITED INS'I'ALL.ATION WARRANTY. We provide a workmanship warranty that the System shall be Gee from material defects in design and workmanship under normal operating conditions for the Term. We further warrant that all rooftop penetrations We install shall be watertight as of the date of installation. We do not provide any warranty a You with respect to any component of the S}'.�hem. Any manufacturer's warranty is in addition to,lit m lieu of this limited installation warranty. This warranty does not cover problems resuhing from exposure to harmful materials and chemicals, fire, hood, earthquake.or other acts of god,vandalism,alteration of system by anyone not authorized by Us,or any other cause beyond Our control. B. MANUFACTURERS'WARRANTIES. The%stem's solar modules carry a minimum manutacturer's warranty of twenty(20))years as 1'ullows: ((a))during the first ten(10)yyears of use,the modules'electrical output will not degrade by more than tell percent U0%)fain the nriginal(v rated outvvtit:and (b)dieing the first twenty(20)years of use,the modules'electrical output will not degrade by more than twenty portent(2000/u)from the ongiwlly rated outpor. The System's inverters carry a minimum manufacturer's warranty often(10)years against defects'or component breakdowns. During the l era,We wilf enforce these warranties to the fullest extent possible. C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3, WE MAKE NO OTHER WARRANTY TO YOU OR ANY OTHER PERSON, WHETHER EXPRESS, IMPLIED OR 9•TA•fUTORY, AS TO THE MERCHANTABILITY OR FITNESS FOR ANY PURPOSE OF THE EQUIPMENT, INSTALLATION, DESIGN, OPERATION, OR MAINTENANCE OF THE SYSTEM, THE PRODUCTION OR DELIVERY OP ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HEREUNDER, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANY BREACH OF ANY WARRANTY IS LIMITED TO REPAIRING THE SYSTEM OR YOUR PROPERTY TO THE EXTENT REQUIRED UNDER THIS AGREEMENT. YOU ACKNOWLEDGE THAT WE ARE RELYING ON THIS SECTION 3_C_AS A CONDITION AND MATERIAL INDUCUMEN'T "f0 ENTER INTO THIS AGREEMENT. THERE ARE NO WARFGWTIBS WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. 4.REMOVAL OF THE SYSTEM Y'ou Shull not sake env Ntcvutions(us Jeflm•J in Section Ylen w dre_Svstem, 11'You wain w make repairs or imppnreunams to Your I'ropeny that require the temporary removal of Ihe System or that uuuld Interlure•wvh its performance or operation.You muss five Us at Ices Thin"(.10)Jays'poor wnuen mace (a"Caganmr-Requcvrd S/urtdmori'). You ane,that;mv repair ur mtprmenklIt m Yuur Properly shall not rnactially allci Your rail"'here the System is almated. As campensaliun tin Our rtmoc:d,slumgc,nndrennnell:nion of the System.You agree to Pay to Us a fee equal to pour I hundred and Nana-Nine Dollars hot Po)before,o ,1 1 the System. cams shall be required In pay the Shutdown Poynrenl ll oruio in 4cunn E 51 it Ihe a.,c is nut reirisudled arnhin Thirty I c')diva ol'rcntirval. Ville eycm of an emergency d qUa ing the$ instil Yuu skill a IlIe S Us unrmI ly. If We me unable In Ninety beemer Vac pray(;d Yuur awn axpsnse)or slyc with a Ii)the d:rod qualified solar itutmio to remove the ur cral as nexess'afv m make repairs ryuird by the emereelsy. You shall he resprnsthle fi)r arts•Jmmoge w Ihe Syslean that tcauh5 IFum action-taken by Vuur commuter. 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quick)y and amicably b solve y calling Our customer service department at(877) 404-4129. If Our customer service department is unable to resolve Your concern,You and We agree to re any Dispate(as defined below)through binding arbitration or small claims court instead of courts of general JMurise iction. BY SIGNING BELOW,YOU ACKNOWLEDGE AND AGREE TIIAT(I)YOU ARE HI",REBY WAIVING THE RIGHT TO ATRIAL BY JURY;AND(II)YOU MAY BRING CLAIMS AGAINST US ONLY IN YOUR INDIVIDUAL CAPACITY,AND NOT AS-A PLAINTIFF OR.CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESENTATIVE PROCEEDING, You and We agree to arbitrate all disputes, claims and controversies arising out of or relating to Of OI'R AFIIII-1TF9. UIFF(TOR2 . I-MPLO)I I'S. AG['N9C. Iu I OR (ONIRAC ORS [OR ANY' SPFCIAI FXLMPI.AR�. - INIATIA 1. INCIDF N'I AL. (ONSLQUI-NIIAL OR. PI N)IINJ7. DAV1A61-1,(ll'HL IB R OR NO'F HIT ('I-AIM I'III RIT010, IS RASH)(IN CONFIR:AW. CORE. M 711' IAIPOSFD BY L At OR OTHFRAAINI:),IN (UNNPCTIOh WI'111. :ARISING ON CIF,OR. IN :ANY ttiAY RI'LATI-1) TO TIIL IRANSAC'TIONS - - - C'(1NT"IPI.ATFD BY HUI AGRfI.ARNI OR ANY ACT OR - OMISSION OR FVENT 0U.1 RRIVG IN (O\NI-('I ON FIJIRLWHILYOL: HLRI.BY W'AIVI . PI I LASL,ANOA61REI. ;r_ EvIy. irn NO[ 10 4C1: l PON A,Y SLCH CLAIM FOR ANY SIX H DAU N(W AtHILDQR OR VUF AC( RA ED AND WIIFFHLK OR NUT Quo OR SI SI'ICl'FU TO FXISI IN YOCR - FAAOIC Y(NI ILRDWR 4(AH T111 NO CLAIM. LrAWWIF. OR NNY O`FIIER LEGAL OR AR13HRA"HON n PR(I(1'1?DING IA ((ri NFCIIOV WITH.,NKhIN(i Ol1T UF.OIL `- ' '' ' IN ANY VA'AY RBIA"IL:D 10 HIS AGRII?dENT MAY 131 - BROL(OH. ('OAISIFN('F.D OR FILFD MORL TITAN (ME 0) N, -iRWU .� YEAR AI Ilk H IL IAC.IDI`:T Glb'ING RI>@ rO SLCI I CLAIM. Y'OL, A('KNOQ A'IADGC THAT AAF WE RELY MA ON THIS SECTION 17 AN A (ONDITION AND MAHvWA1. INDliCBV1FNT TO FN'F!-:it INIOTIIIS A(iI2 P:FAIENI. �• ' ISANDEBINIFIC VTION. 'Fo llie fu11,,t exmit permitted by - ,. I (;linr y I 1'.�IU Lk p t r VI mW t l I: n e Irz II +wml r a�n. ., • ._ m•�J Irv . ' ; n�IIJ� iI' S. I r, �c P� puiiin ' '.a 1 . 1 �. .nJ fnnr. J ..tsln:n;6:Vt lafnee ur.0 p I 24.Pltb�f It I I N ANTI ORI-UI I Ntllf E THLS ..PR.S RFIINI- OFFER OF CRFDHBASED ON INFORN AlION IN YOUR CRLDIT RLPORT INDICAI-ING n THAT YOI I WBP:F YO['LAINDO CRITERIA. THIS CRITERIA R I NOT ,r ...! �• 1 �. • . .. _ .I � , _ .�. . GUARANI I I:U IF 1'Of' DO N(ll' b16f1' OUR t'RITFRIA IF :+ rdl',I-�• . . YOU DO NO[ WANT' 10 RE('EIVF VREWREENLD OFFERS P1.11 RR HI.A I TUN OF('RI;UFC FR T G UTI16R TO COMPANIES.CALL THE �o.i• Iv. -i .•• .m �.�rl., - nl.� -„ - CUPiSU n4Rl2 REPORTING AGENCIES TULI:FREE, (08) 557- � n,. ..�. .. S ,.n us. _ i ai ftl RF:OIL VA'IR II'E: EXI'G:IAN OP'f OUT.P.O.BOX 019 ALLEN. `o,N TX ?5011: ITANSUMON NAME REMOVAL OPTION_ P.O. d R Iw' R •AIL' ,❑ p, L_i ,I BOX 503 WOODLYN, PA 19094: FQUIFAX OPTIONS, P.O. 20.ANIENWIE: CS AND kNNBFRe Thu do-In Bo N. 740133ATLANIA.GA 30374-0123. 0)any aspect of the relationship between You and Us.whether based in cunt met.loft.salute or mry other legal theory:(if this Agreement or any other agreement coneernme the subject natter hercoC (iii) any breach default, or termination of this Acrcement; and fiv)the interpretation,validity,or en orctand iry ufthis Agreement,me]Lid in-the dclennination ofthe scope or applicability rthis Section 5(each.a "Divpule'). Prior to commencing arhitralion.a party must first senrla written"Notice of Dispute' via cerlifcd mail to the other pp myy. The Notice of Dispute most deserihr the nature and basis far the Dispute and the relief sought. II You and We are unable to resolve the Dispute within thirty (ift) days, then either party nun' commence arbitration. The arbitration shall be administered by JANIS pursuant to its Streamlined Arbitration Rules and Procedures(oral(o6le nC hopp/lwww.amsadreomhuls -streamlined-arhitralion,the"J.bIf.S Ru/ec")and under the rules set forth in this Acrcement. llic arbitrator shall be hnunti'be the terms of this A,,rectrient. No natter the circumstances,the arbitrator shall not award punitive,sppecial,exemplary, indirect.or consequential damages to either party. If You initiate arbitration. You shall he responsible it, pay 5250. All attorneyti lees, travel expenses. and other costs of the arbitration shut be borne by You ant] Us in accordance with the JAMS Rules and a rplicah(c law. Thearbitration shall be conducted at a nmtually agreeable location twar Your Property. Judgment on an arbitration award may�c entered in all eourl of compctem jurisdiction. Nothing in this Section 5 shall preclude You or\Vc from seeking provisional remedies in aid of arbitration frwr a churl of competent jurisdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY RE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION TO NEUTRAL ARBITRATION. c,at„mr,ts Itilit,,i,. 1/WF,AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: 6.NOTICE TO CUSTOMERS / A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,(it)the Additional Terms and Conditions,(iii))the Customer Packet,and(iv)the Work Order. These documents are expressly incorporated into this Agreement and apply to[he relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT, C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement,that We have signed the Agreement,and that You have read and received a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both You and Us,before any work may be started. (E(. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME ppPR))IOR TO THE LATER OF: (1)MIDNIGHT OF THE THIRD THE)BUSINESS DAY AFTER NOTICE OF CANCELLATIOON BELOW FOR AN EXSACTION P OR ATION OF THIS RIGHT. THE START OF TALLATION OF THE SYSTEM. SEE VIVINT SOLAR DEVE`hO _,C CUSTOMER(S): Printed Name: ( lam' C - Printed Name: rf)Cj.qf\ By fj Title: �— t/.. ff Printed Name: Transaction Date: (}� FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION: TEN PARK PLAZA,SUITE 5170, BOSTON,MA 02116, (617)973-8700 OR 888-283-3757. __ NOTICE OF CANCELLATION Transaction Date: AR No.: YOU:MAY CANCEL THIS TRANSACTION,WITHOUT ANY PENALTY OR OBLIGATION,WITHIN THREE(3) BUSINESS DAYS OF THE ABOVE DATE, OR (IF LATER) UNTIL THE START OF INSTALLATION OF THE SYSTEM. IF YOU CANCEL,ANY PROPERTY TRADED IN,ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE. SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE,IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE i AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY(20)DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL,TO DO SO,THEN YOU REMAIN LIABLE FOR PERFORMANCE OF At,[. OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOL §DEVELOPER,LLC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO THE LATER OF: (I)MIDNIGHT OF THE THIRD(3 )BUSINESS DAY AFTER THE TRANSACTION DATE,OR(II)THE START OF INSTALLATION OF THE SYSTEM. 1 HEREBY CANCEL THIS TRANSACTION: Date: _ _ Customer's Signature: VtlItIION vI 11 R\b YAD(UV I1)I ltiv,v it t : I1 .. •. t n..,.. 1 9 l,:r tf In + • • i IA. OI Itll 1 Y I 11 \• Ir 1. L: Ill ID(IAAAa I I, 1 11 Lit 1 11I,� n q1 r .I Y r II It h. , ,•J a n Iwo ,. \L. el ,TIT J'a i rM-- l. n. er it �li� 11I UI [UI,I\h 1�VI I<LA 1 I 4 I.. ! I r 1 l rI ,I V ".1 1 bm lit u I re/'m xn+vit ill IT,N tII, I' r II,It f. ail ,.I•: I .. I ,ia1 1% ulll 'J tl. 1 IT I .1 'J ,1 11I 11'itio, tl Ja III.t I. I '1. u l 1 1 1 fi lit i 11 It ' „ 7,.1I Jill 1 I. . \, U: 1 ,. ' Y \ •11 \ \ V` i 1 44 r \ I Ilc• IT Y I'f lit;I AI AIh l.itl t! uU 1 r a-t 1 J .h, n, \ 1 1 5I -I li h If .I r 1, �:IA r ,.Ili •,u t II .,.YI I a ct-J - I 1 i- Y-r. m ,. bran 1/qum f r •I II d I I ILL I'i IL 11N\I N�IIII•rtl \�144 9 t.l it w.I „aI I, h. 1 tl.v \ , t t r: l it I u•i: ul 1 I r. . 1 Lr - �M1t. i 'I1. P r,.} t Ar u' 1 vnIt II -put t nll l A fi_ :ml ryh tr f_Itr r4 mra 7 V r , r( Iu1 I it IN 1 Jl. t ht ',al a1i r.ltor t � c nm s'-.rI .I il.rr ha ca. it ILa I i}a � I%It I r i.11 ll � r I - I.n. i II IaI I:b• r t Lt. I t IT, I I 9I �r. pP of ,I. .Il r r.. .I .I1 I: a h It IT.111 J ,I ),-1P1 II 4 I.. l 'f ! .1 lu - r rI 1.1,n i II 'r I (tl 11 '. it IT •� ie+lcl Ins.lx r r'J. hr I Ill 'I nalyr Fn I.IiV111V�10A(ff1116111T5 Y�r Itd.-.aa u7fidr 11Rc mm�nn ur uc'f ....I Y ., I• rl 15 .il 1�1 k In 4 ,h I. Ir1 al I' t ,I a i I II'll 1, I ! 'I• 19 i rl I I \, I nr I r I 1 I I I t I.r r t I .Ira 1 1ch• ( r ,!I a rrr , I, a,a ,L :L(.. � •-a i� .:1 t Y I L „ :a - -6 NO'Fill HS IANDMG ANY BREACH OF THIS AGREEMENT. .�:.I r Ih ,.•ri ANY FAILURE OF THE SYSTEM,OR ANY NEGLIGENT ACT THAT CAUSED ANY INJURY OR LOSS (WHETHER 12. \\w\w.�•r LI Il("YII'.It L '. ti PROPERFY DAMAGE, PERSONAL INJURY OR DEATH) TO ANYONE. WE AND YOU AGREE THAT, UNLESS SUCH teal IA Ir I' \: •: I -t..a n - 'n° INJURY OR LOSS WAS CAUSED HY A PARTY'S GROSS NEGLIGENCE, FRAUD. OR WILLFUL INJURY, SUCH I ,'`',� ' '•'" ' '""' '1 �" PARTY'S LIABILITY ARISING OUT OF OR RELATING TO IT 1 '•I TIIIS AGREF.MF.NT SHALL IN NO EVENT EXCEED THE -rc - Ijo", 1 • 1 1. ...... .i, i ,. DEFAULT P.AYMENI'. YOU AND WE AGREE FHAT THIS Tit It , ill I AMOUNT IS A FAIR REPRESENTATION OF THE DAMAGES Ili' ,.1 1 I I"1"t I r I' ,� t,'' THAT YOU OR WE EXPECT TO INCUR IN THE CASE OF ANY 1, \ tr,q Irh 1. I Lit I .li Aa.,, -'a ,I tit.11 lh: I' INJURY OR LOSS HEREUNDER. "' 1 - 1 v'r„ „ NO CLAIM SHALL BE.MADE BY YOU AGAINST US OR ANY Pr.. _ Y I I. a.l \N.. r T., f ll I i.,p,I I ,. F- - -- - - ---- ---- - -- - - - -- --- - (D a'mw ( CD I � �o z E� (35)Tnna Solar TSM-250 PA05.18 MODULE I Q N O C Q I N Q E o cu ( . U) I � � PV SYSTEM SIZE: 8.75 kW DC I •o � � m P JUNCTION BOX ATTACHED TO I y U ARRAY USING ECO HARDWARE TO z a KEEP JUNCTION BOX OFF ROOF PV INTERCONNECTION POINT,INVERTER, I w w z m LOCKABLE DISCONNECT SWITCH, m < 3 ANSI METER LOCATION, 0'OF 1"PVC CONDUIT r F. S UTILITY METER LOCATION FROM JUNCTION BOX TO ELEC PANEL I z i o SHEET NAME' LU Z � g Ua --------- -- ---_- -- — —_ — _—_ —_ —_— J SHEET NUMBER' PV SYSTEM SITE PLAN o SCALE: 1/16"= 1'-0" > H ♦ m H O 000o Nm 3[n a (A mm OA 00 O �'J J NN m= m� v C Se m z m z 4 m J� Oti pA CZ m N N l/ D � r CI) m � w C/) N m 0 X o o z T 0 m Z �= z ImjINSTALLER VNINTSO AR .I,M,1['n17 C ry Marino Residence P\/ f z o ROOF ^m MA LICENSE:MAHIC 170848 044128 V V Y Y Y. V O 1 Belem,MA 0 970 V L PLAN NI URAWN BY:RBR JAR4218384 I Last Modified:3I18I2015 UTILITY ACCOUNT NUMBER:88106 B5000 CLAMP MOUNTING SEALING U PV3.0 DETAIL WASHER LOWER SUPPORT ® cn/ N� az Ez r mvz ten,,.}-:...,:... 0$h o PV MODULES, TYP. MOUNT "' ""` C OF COMP SHINGLE ROOF, FLASHING PARALLEL TO ROOF PLANE J 2 1/2" MIN 5 5116"0 x 4 1/2"MINIMUM L PV ARRAY TYP. ELEVATION STEEL LAG SS CREW NOT TO SCALE TORQUE= 13±2 ft-Ibs O CLAMP ATTACHMENT (!) NOT TO SCALE � m CLAMP+ ATTACHMENT CANTELEVER J4 OR LESS oc=m E COUPLING J L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. S � PERMITTED COUPLING 5 - c CLAMP+ CLAMP CLAMP y �a ATTACHMENT SPACING COUPLING PHOTOVOLTAIC MODULE K K W z T W 2 m W J SHEET NAME: L=PORTRAIT CLAMP SPACING ~ Z Q 0 LE ECO M p COMPA L=LANDSCAPE MODULEIBLE PV SYSTEM MOUNTING DETAIL SHEET CLAMP SPACING NumeEa (MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE a solarEEge Power opnmiaer Pia Eaed.0 In,": nput Powar-3a""' Signs(See Guide Section 7) PV Module Ratings®STC(Guide Section 5) Marimum Input Voltage-aa Vtic MPpl Range-g. Vdc MObel..Wmtgel Irene SaarT INT350 PA0518 Mdaimum Input Correct AEC Maximum..real C-min-15Atic Sign for inverter OCPD and AC Discamoect Mae Power-Picnictmn'tral 827 Amy rme umitTrom-e to20opdmimrs,E2s0wTta STC per string maximum Solar PV System AC Point of Connection Max Power-Pam Voltage romp) 303 Vora PVWirein P,eAiror THHN2/THWN2in3/0"conduit .pervclumand Voltage isymn 31.6 Voile O AC Output Curren) 32 Amps Shot CircuitCurrent usa gas Amp. W Minimum 30 AWG Cu wire each(rated 90 deg Cl v✓ Poalnve,rveeume 6dre copper EGc Orin:mined GFaneanam Nominal AC Voltage 240 Is Maxsal Maximum Dowel a Amy C: m seep under 2%voltage drop Nominal Maximum Power of src(Pma.l 21 wads C Maximum System vobaee I MCORE C)rs6oem) THIS PANEL FED RY MULTIPLE SOURCES 's Temperature Campeau Mlmmam a Awe Cis wire(rated a deg q Ll,L2,and neu Val9 AW6l nE wire In ge drupior 1"PVC conduit N Q q m Nepal l.5%volbgedrop (UTILITY AND SOLAR) NOTES FOR ARRAY CIRCUIT WIRING(Guide baetien6and Band Appendix Gl: �E+¢. O/%f/oad SolarEEge sE]6aA�usulmener 9J.5%CFC ERciency@2i0Vac System labels 1J Lowest expeclM ambiMl temperature based on ASHRSE minimum mean eMmme Ld�v E? ]6W Wac mnllnuous Mavlmum Outpm Nrren132 Amps Maximum DC VoIIaBe=SDD Vtic tlry'EUlb lemperaWm for ASHRAE Iowlian mess similar le installaton laca5on: -19°C 1 Mav mum Input Current 23.5 P4c Ground fault protection pravided Nominal Element Voltage=350 V �'x N O par NEC article g9b35 Maximum.CCurrent=ISO Atic per stung 2J Hgxasl continuous ambient temperature based on ASHRAE highest monpl2%dry bulb C a Max Carl ntt 150ut AddCurrent=32A grop¢raWre for ASHRAE brother,most similar to installation larente: 39°C °L Solarftlge Af/OC Safety Switch 4E0 Va450 amps continuous e 3.)2005 ASHnalE fundamentals 2%deals.lemperaNres do not ezcee0<]°C in TO _ Cc 6CO Vdc 3ii amps continuous Opens all ungrounded cendurma United States(Palm Springs,CA is".l°C).For less than 9 carried carrying comma to rs GGG j per NEC arlide soli in roof-raounleb sunlit rnndub at least 0.5'above roof and using Me ouMoor design temperature of 47°C or less(all of United Stales). aJ 12 AM,9f1°C coMUGws are gercraity acceptable for modules with 1.of 7.68 Amps or less Men proleGed by a 12-Amp or smaller all b.)10 AWG,90°6 condugoro art generelly acceptable for modules wdh Ica of 9.6 Amps or Sees when pmlM¢d by a 15 Amp or Smaller Mae. �L xV PV Modules=250 Watts STC Q 35 Modules per Inverter= 8750waUS STC (n m 1 string of 18 PV Modules SGWiEDGE 1 string of 17 PV Modules BE 7500 C INVERTER To 1� To N Lt 12 , v SUPPLY-SIDE •�``O O 0 0 0 0 1] 18 1a SOLAR / TAP EXISTING ENTRANCE ((/ Ta,.IJW CONDUCTORS RATED: o a o _ = 10/Ado $ do VISIBLE y m ¢ LOCKABLE 240V/100A Ed a 'KNIFE' PANEL o o a a a O O MEEi/Arvsl ON j . F 1 2 3 16 17 METER DISCONNECT Ed W N w 2 m L1 40A- - a a o - Lit SHEET ET NAME N W Q Z Of G 2aA J (D MgaANK law OR SIEMENS SIEMENS cS Q Ease ieie #LNF222R 60A/240V GEC UNFUSED FUSED —Ground SHEET 60A/240V NEMA3 TO NUMBER: NEMA3 GF222R EXISTING OR OR LOAD-CENTER C) EQUIVALENT EQUIVALENT W C D C) O cm (n () � O z 3 (Zn v o �N �1 T1 o m C D cp (n Z m z D N O m D O o � 9 C N m 4 c m a a f- go o° om mD Np z Ci Dm INSTALLER: UMBERIVINT 187 RW�, a�lqa M'' 1'[jn'�'f Marino Residence ;m OESIGN 3m INSTALLER NUMBER:1.877.4044129 V V �Y YY ����� PV 4.0 p mm LOGIC m MA LICENSE:MAHIC 170848 nt 54 Belle new Ave Salem,MA 01970 DRAWN BY:RBR JAR4218384 Last MotliBetl.3/1&2015 UTILITY ACCOUNT NUMBER:88106 85000 EcolibriumSolar Customer Info Name: 4218384 Email: Phone: Project Info Identifier: 27836 Street Address Line 1: 54 Belleview Ave Street Address Line 2: City: Salem State: MD Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-250 PA05.18 Module Quantity: 35 Array Size (DC watts): 8750.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: SE760OA-US(240V) Project Design Variables Module Weight: 41.0 lbs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load -Lateral: 288 Ibf EcoX Design Load -Downward: 722 Ibf EcoX Design Load - Upward: 765 Ibf EcoX Design Load - Downslope: 297 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar Plane Calculations (ASCE 7-05): 2 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 25.0 ft Roof Slope: 24.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.84 0.84 0.84 Roof Snow Load 28.2 28.2 28.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 28.2 28.2 28.2 psf Downslope: Load Combination 3 11.4 11.4 11.4 psf Down: Load Combination 3 25.7 25.7 25.7 psf Down: Load Combination 5 12.1 12.1 12.1 psf Down: Load Combination 6a 27.3 27.3 27.3 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 27.3 27.3 27.3 1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 62.9 62.9 53.0 in Max Spacing Between Attachments With Rafterrrruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.0 21.0 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.7 48.7 41.1 in Max Spacing Between Attachments With Rafterlrruss Spacing of 16.0 in 48.0 48.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.2 16.2 13.7 in EcolibriumSolar Layout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal expansion and contraction. See Installation Guide for details. O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with ® Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 20 Weight of Modules: 820 Ibs Weight of Mounting System: 154 Ibs Total Plane Weight: 974lbs Total Plane Array Area: 352 ft2 Distributed Weight: 2.76 psf Number of Attachments: 77 Weight per Attachment Point: 13 Ibs EcolibriumSolar Plane Calculations (ASCE 7-05): 1 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 25.0 It Roof Slope: 24.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.84 0.84 0.84 Roof Snow Load 28.2 28.2 28.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wnd Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 28.2 28.2 28.2 psf Downslope: Load Combination 3 11.4 11.4 11.4 psf Down: Load Combination 3 25.7 25.7 25.7 psf Down: Load Combination 5 12.1 12.1 12.1 psf Down: Load Combination 6a 27.3 27.3 27.3 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 27.3 27.3 27.3 1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 62.9 62.9 53.0 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.0 21.0 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.7 48.7 41.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.2 16.2 13.7 in EcolibriumSolar Layout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal • Clamp expansion and contraction. See Installation Guide for details. Warning: PV Modules may need to be shifted with respect to roof trusses to comply with ® Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 15 Weight of Modules: 615 Ibs Weight of Mounting System: 154 Ibs Total Plane Weight: 769 Ibs Total Plane Array Area: 264 ft2 Distributed Weight: 2.91 psf Number of Attachments: 77 Weight per Attachment Point: 10 Ibs EcolibriumSolar Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 77 ECO-001_102 EcoX Coupling Assembly 40 ECO-001_105B EcoX Landscape Skirt Kit 14 ECO-001_105A EcoX Portrait Skirt Kit 0 ECO-001_103 EcoX Composition Attachment Kit 77 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly(optional) 2 ECO-001_106 EcoX Bonding Jumper Assembly 7 ECO-001_104 EcoX Inverter Bracket Assembly 0 ECO-001_338 EcoX Connector Bracket 0 ECO_001-359 EcoX Lower Support- Low Slope 0