Loading...
42 BAY VIEW AVE - BPA-15-1172 SOLAR The Commonwealth of Massachusetts c{� a)44 Board of Building Regulations and Standards REC«C `CaF���C S Massachusetts State Building Code, 780 CMR iNSPE TICSALV1 v Rew.ved),Iar2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a OCj Zb A � One-or Two-Fcmzily Duvelling 10t5 r— This Section For Official Use Only c' Building Permit Number Date pplied: L /lw,, 1� Building Official(Print Name) Signature V Date SECTION l: SITE INFORMATION r'n 1..1. Property Address: 1.2 Assessors Map &Parcel Numbers �+ 42 Bay View Avenue Salem,MA 01970 I.la Is this an accepted street'?yes no Map Number Parcel Number 1.3 Zoning Information: lA Property Dimensions: Zoninc District Proposed Use Lot Area(sq tl) Frontage(ft) 1.5 Building Setbacks(ti) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L a 40.§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: _ Outside Flood Zone?Check El Private❑ Check if yes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Robert Cook Salem, MA 01970 Name(Print) City, State,ZIP 42 Bay View Avenue Salem,MA 01970 978-744-0416 ddycelaine@comcast.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK' (check all that apply) New Construction ❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other s(Specity: Solar Brief Description of Proposed Work`: Install 2.6kw solar panels on roof.Will not exceed roof panel,but will add 6" to roof height. 10 panels total. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) L Building $1,000 1. Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $10,000 ❑Standard Cit)dTown Application Fee ❑Total Project Cost'(It'em 6)x multiplier x 3. Plumbing $ 2. OtherFees: $ 4_Mechanical (TIVAC) S List: 5. Mechanical (Fire $ _ Suppression) 'Total All Fees: $ Check No. Check Arnount: Cash Amount: 6.Total Project Cost $11,000 11 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5A Construction Supervisor License(CSL) 103631 8l30/17 Gregg LaCasse License Number Expiration Date Name of CSL Holder List CSL"fype(see be-low) U 20 Patterson Brook Rd. Unit 10 No.and Street Type Description U Unrestricted(Buildings up to 35,000 en_ It.) W.Wareham, MA 02576 R Restricted 1&2 Family Divellin Cih/fo n. State " IP M Masomq RC Rcxfin>Coverine WS Window and Siding SF Solid Fuel 13umine Appliances (508)291-0007 I hisulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 170355 10/12/17 Tom Blumetti/Trinity Solar HIC Registration Number Expiration Date HIC Company Name orHIC Registrant Name 20 Patterson Brook Rd. Unit 10 No.and Street Email address W. Wareham, MA 02576 (508)291-0007 cof Town,State,LIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building pennit. Signed Affidavit Attached? Yes ..........I( No...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize Tom Blumetti to act on my behalf,in all matters relative to work authorized by this building permit application. Please see attached letter. 10/20/15 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER`OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury, that all of the information contained in this application is e and accurate to the best of my knowledge and understanding. Tom Blumetti 10/20/15 Print Owner's a'Authorized Agent s Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIQ Program), will nor have access to the arbitration . program or guaranty fund under M.G.L.c. 142A. Other important information on the FITC Program can be found at wbym\•.nmags. ovg /oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage, finished basement/attics,decks or porch) Gross living area('sq. fL) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President October 15, 2015 Salem Building Department Salem,MA Re: Solar Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional framing is 2x6 at 32"o.c.with 8'span(horizontal rafter projection). This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project after sister the rafters with a 2x6 using (2)10d nails V o.c. Use of (2)Guard DogTm FMGDO02 screws is approved,or equal shear strength of approx. 120 lb, 1'o.c.at areas where little space is available only with remainder of member secured with(2)10d nails V o.c. If do not sister,then install a 2x4 @ 32" o.c. knee wall over an interior bearing wall to limit span of rafters between supports to 7'. 2. Roof Loading • 4.33 psf dead load (modules plus all mounting hardware) • 30 psf snow live load(50 psf ground snow live load reference) • 4.5 psf dead load roof materials • Exposure Category B, 115 mph wind uplift live load of 19.6 psf(wind resistance) 3. Address of proposed installation: Residence of Robert Cook.42 Bavview Avenue,Salem, Massachusetts This installation design will be in general conformance to the manufacturer's specifications,and is in compliance with all applicable laws, codes,and ordinances, and specifically, International Residential Code/ IRC 2009, 2011 NEC, and 2012 [CC Energy Code. The spacing and fastening of the Unirac mounting brackets is to have a maximum of 64" o.c. span along the rail between mounting brackets and secured using 5116" x 3'/2" length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min.2" penetration of lag bolt per bracket,which is adequate to resist all 115 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load. Penetration of anchors for modules mounted within 18"of ridge and edges of roof is to be a minimum of 3". Rails may be attached to either of two mounting holes in the L-feet. Mounting in the lower hole for a low profile, more aesthetically pleasing installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more.Slide the 3/8-inch mounting bolts into the footing bolt slots. The rails will be attached to the footings with the flange nuts. Very truly yours, Optimize Engineering Co., LLC MgS$gCy Richard B.G6rdon, P. . ° N � RICHARD B. m Massachusetts P.E. License No. 49993 o GOROON MECHANICAL ENGINEERING o MECHANICAL " CIVIL ENGINEERING NO 49993 ELECTRICAL ENGINEERING `�' O/STe40 ;S;ONAL SNAPNRACK SERIES 100 ON FLASHED L-FEET REVISION, FLASHED L-FEET ARE OPTIMIZED FOR QUICK AND ROBUST INSTALLATION ON STANDARD COMPOSITION SHINGLE ROOF SURFACES FOR OTHER ROOF TYPES STANDOFFS ARE RECOMMENDED ��JJID C TL�77]nCil-ID:LLLTr>z SNAPNRACK STANDARD RAIL ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR STRUCTURAL MEMBERS SUCH AS STEEL PURLINSO ROOF SHEATHING,UNDERLAYMENT, AND ROOFING MATERIAL® FS 3EEI-IE11 n I IIIEf I-I ( ,�n� ����p (,,,, WINSTREPM ENERGY CORP DESIGNER: GMcPh,0.e SCALE ® PARTNUMBER. DESCRIPTION REV 51 Uvul 1J�`jv(amzl ) ��- '� ogn Ell DR'� 810D 001 SERIES IOD OVERVIEW.ON FLASHED C ^ Sao ,,.R. a�., r APPROVED SY: DAflF ® L-FEET RFdIS10N: SNAPNRACK MODULE ATTACHMENT HARDWARE SNAPNRACK STANDARD RAIL ROOF SHEATHING,UNDERLAYMENT, AND ROOFING MATERIAL® ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR STRUCTURAL MEMBERS SUCH AS STEEL PURLINS IZIIII-TrM RTtTF oi➢Li�'iiTZrm 11 ^++ p MAINSTREn ENERGY CARP DESIGNER: QWPMe., SCALE: PARTNLMBER. DESCRIPTION p.y k� ' . °'• " °"" DRAFTER DRya 8100002 SERIFS 100 OVERVIEW.ON STANDOFFS F A LL'.�QE1f9�'1,� }Taw�4.H.TP.". •':s,:x:»•fir,::x:;ti,:�;,:.:.:::- APPROVED BY DATE: SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT REVISION NOTES: -STANDARD LAG BOLT SPEC ASSUMES 5/16"LAG BOLTS WITH 2.5" EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL I"HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR -SILVER S.S. to-16 FT-LBS STRUCTURAL MEMBERS -BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE M DOWNSLOPE) -FOR UNEVEN ROOF SURFACES, USE -SNAPNRACK MODULE UP TO TWO LEVELING SPACERS PER L MID CLAMPS MODULE OVERHANG FOOT OR STANDOFF.SEE DRAWING \' (NOT TO EXCEED 300 "STANDARD RAIL LEVELING'FOR OR MANUFACTURER'S DETAILS AND LIMITATIONS 1 RECOMMENDATIONS) MODULE OVERHANG . STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER ^"e i "RAILSPAN" DISTANCE BETWEEN ROOF ATTACHMENTS "RAIL END OVERHANG"(NOT TO EXCEED 34%OF ACCEPTABLE RAIL SPAN) ' �j MAINSTREAM ENERGY CORP. DESIGNER: IWPho.' , SCALE DNS PARTNUMBERr DESCWPTION- REV Snap1 [ack- DRAFTER. D Ryan S100 D05 SERIES 100 TYPICAL I-AYOUT F DATE APPROVED BY: : 120113 -1X SNAPNRACK -2X SNAPNRACK LEVELING REVIS10m USE CARE DURING LEVELING SPACER SPACER - INSTALLATION TO ENSURE 4 THAT THE SET SCREW IS -1X-j`-18 X 1"LONG - 2X{g"-18 X 1"LONG ROUGHLY CENTERED BETWEEN y SET SCREW R SETSCREW THE TWO PIECES BEING®INED •9 Y n 51 ANDARD SERIES 160 ATTACHMENTS FEATURE 3"OF VERTICAL AD1 7ABIlIFY ON ALL MCUNTING POINTS WITH -• f1HE USE OF 1"LEVELING ORE (SPACERS OID ® ® THE FIRST INCH OF ADEUISTABILFFY IS ACCOMPLISHED WITH SLIDING DETAIL A FEATURES BUILT INTO BorH L SCALE 5:8 FOOT AND STANDOFF CLAMP COMPONENTS t I 1 t RAIL HEIGHT 1:17.5" RAIL HEIGHT M.5" F RAIL HEIGHT CD.S" RAIL HEIGHT❑'i0.5" FOR AN ADDITIONAL INCH OF ABOVE ROOF SURFACE ',ABOVE ROOF SURFACE ABOVE ROOF SURFACE ABOVE ROOF SURFACE HEIGHT ADSUSTMENT,ADD h 7" STANDOFF `7"STANDOFF 7"STANDOFF 7"STANDOFF ONE LEVELING SPACER. USE PLUS ONE SPACER PLUS TWO 5PACERS Of 5114GLE L[VEI-ING SPACER ON TOP OF STANDOFF d ON TOP OF STANDOFF NOT TO EXCEED 300 OF ATTACHMENT POINTS ON - l_FEET OR 10' STANDOFFS. 9 ' FOR A SECOND ADDITIONAL t INCII OF HEIGFFT _ 'ADGJSTMENT,ADD ANOTHER 1 IFVELING SPACER. USE OF t •- • -TI, TWO LEVELING SPACERS NOT TO EXCEED 10O OF DIE _ - ATTACHMENT POINTS ON ' 1 C L-FEET OR 10'STANDOFFS. F RAIL HEIGHT M.77 RAIL HEIGHT mQ s RAIL HEIGHT LIS.LS =- RAIL HEIGHT CS.Q ABOVE ROOF SURFACE `-_ ABOVE ROOF SURFACE D ABOVE ROOF SURFACE ABOVE ROOF SURFACE ONE L FOOT ''ONE L FOOT ONE L FOOT ONE L FOOT PLUS ONE SPACER PLUS TWO SPACERS UNDER L FOOT UNDER L FOOT /r MAI N6IPAd ElEPGV CORP DEGIINER 0WPneebre scl-E PART NUMBER DtSCR PTUY REV F oe�FreR c u;".,,, 5100 DOS SERIES 100 RAIL LEVELING i lib rig A'9.9'w= - Aervmveu Er UAIE 1 REVISION USE TILT KIT OPTION FOR INSTALLATIONS '\ THAT REQUIRE MODUI ES TO BE TILTED ABOVE THE EXISTING ROOF SLOPE SYSTEM SHOWN 15 DESIGNED FOR TILT ANGLES FROM 10 TO I3 DEGREES ABOVE ROOF SURFACE ^� USE OF ANTI-SEIZE ON TILT HARDWARE IS RECOMMENDED(PARTICULARLY FOR MAX LENGTH: LB" ` STAINLESS TO STAINLESS HARDWARE) WITH STANDARDI� ENGINEERING { REFER TO S100 TKT SERIES 170 TILT KIT TOOL FOR A SIMPLE TOOL THAT DRAMATICALLY SIMPLIFIES TILT KIT INSTALLATION BY SNAPNRACK SUPPORTING THE UPPER RAIL AHEAD OF RAIL STANDARD MODULE INSTALLATION SNAPNRACK MID CLAMP ASSEMBLY CUT REAR TILT LEG FROM SCRAP . OF STANDARD RAIL "`•,�, ni SNAPNRACK _ 1 TORQUE TO 0-1 HANNE WHEN L SNAPNRACK L-FOOT USING WEEKS.WHEN USING ALL-PURPOSE OR SNAPNRACK BONDING CHANNEL ` L-FOOT COMPOSTTLON NOTES: NUTS,TORQUE TO 14-16 FT-LBS. WEEKS ARE NOT REQUIRED WITH , -TORQUE 1}^ HARDWARE TO THE FOLLOWING UNLESS OTHERWISE NOTED: BONDING CHANNEL NUTS. -SILVER S.S. 10-16 FT-LBS - BLACK S.S. 7-9 FT-LBS -REFER TO ENGINEERING CHARTS FOR RAIL SPAN BASED ON MODULE TILT • X I"(OR L25")S.S. BOLT ANGLE,WIND SPEED,AND SNOW LOAD - BACK SUPPORT"LEG" IS FABRICATED FROM A SCRAP OF RAIL. CALCULATE WITH SPLIT LOCK WASHER REQUIRED TILT LEG LENGTH. USE WEEB GROUNDING WASHERS AT ODINTS BETWEEN L-FEET AND SNAPNRACK STANDARD RAIL SCRAP PIECE - FOR LOWER TILT APPLICATIONS SEE"SERIES 100 TILT KIT 0-15 DEG" -SNAPNRACK PAIL COVER CAN BE USED TO COVER CHANNEL IN REAR TILT LEG MNN TREAM ENERGY CORP DESIGNER CMCP�eeRv; LO4LE PART NUMBER DESCRIPTION REV Mold,�JL'� j I . ,,,"" "-' oRAPT_R OR.. DNS S'100 D10 SERIES 100 TILT KITS 10-45 DEG WITH L C �w Dale FOOT MOUPIT r f:�� tB 8!y39tfi<� _ APPRouEU Br 120113 USE TILT KIT OPTION FOR INSTALLATIONS N THAT REQUIRE MODULES TO BE TILTED ABOVE THE EXISTING ROOF SLOPE SYSTEM SHOWN 15 DESIGNED FOR TILT 1 �ANGLES FROM 10 TO El DEGREES ABOVE ROOF SURFACE ON STANDING MAX LENGI"H: CB" ` \. SEAM MEIAL ROOFS WITH STANDARD ` \ SNAPNRACK USE OF ANTI-SEIZE ON TILT HARDWARE ENGINEERING RAIL STANDARD RECOMMENDED(PARTICULARLY FOR S , TAINLESSITI STAINLESS HARDWARE) REFER TO S100 TKT SERIES 170 TILT KIT TOOL j FOR A SIMPLE TOOL THAT DRAMATICALLY SIMPLIFIES TILT KTT INSTALLATION BY SNAPNRACK CHANNEL NUTS, r SNAPNRACK SUPPORTINGTHE UPPER RAIL AHEAD OF TORQUE TO 10-16 FT-LBS WHEN CHANNEL NUT MODULE INSTALLATION USING WEEBS.WHEN USING SNAPNRACK BONDING CHANNEL "X 1" (OR 1 25")S.S. BOLTS NUTS,TORQUE TO 14-16 FT-LBS. , WITH SPLIT LOCK WASHERS WEEBS ARE NOT REQUIRED WITH , BONDING CHANNEL NUTS. CUT REAR TILT LEG FROM SCRAP OF STANDARD RAIL NOTES: \ s SNAPNRACK SNAPNRACK SEAM CLAMP -TORQUE-�'HARDWARE TO THE - \, ` MID CLAMP ASSEMBLY WIDE OR STANDARD BASE FOI LOWING UNLESS OTHERWISE \ NOTED: -5 LVER S.S. 10-16 FT-LBS - BLACK S.S. 7-9 FT-LBS f\ . - REFER TO ENGINEERING CHARTS FOR RAIL SPAN BASED ON MODULE -j5"FLANGE NUT TILT ANGLE,WIND SPEED,AND SNOW LOAD SNAPNRACK L FOOT ALL-PURPOSE - BACK SUPPORT"LEG"IS OR L FOOT COMPOSITION FABRICATED FROM A SCRAP OF X i" S.S. BOLT RAIL. CALCULATE REQUIRED TILT - WITH SPLIT LOCK WASHER LEG LEN G7H. CUT RAIL AND DRILL TWO J"HOLES AS SHOWN SNAPNRACK SEAM CLAMP -FOR LOWER TILT APPLICATIONS WIDE OR STANDARD BASE SEE "SERIES 100 TILT KIT 0-15 'DEG" X 1" (OR 1.25")S.S. BOLT T$ - SNAPNRACK RAIL COVER CAN BE WITH SPLIT LOCK WASHER USED TO COVER CHANNEL IN REAR TILT LEG MAINSTREAM ENERc G SIGNER SCdLL DNS PART Null%2; ❑ESCRIPTION RE4' ciq (� V LS 7� ,Fltn LRra Sioo oii SERIES 100 TILT KITS 105 DEG SEA Mn F i csau5 7. ao . APPROVEL BY °all, 120113 CLAMP MOUNT NOTES: REVISION -5/16" LAG BOLTS MUST EMBED 25"INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT -TORQUE ALL 5116"HARDWARE TO ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT COMPOSITION L FOOT -SILVER S.S. 10-16 FT-LBS CAN BE MOUNTED IN S.S. FLANGE NUT -BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER . . ANY ORIENTATION -RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW A X 1"(OR 1.25") OF L FOOT(UP5LOPE VS DOWNSLOPE) OF SHINGLES ABOVE SNAPNRACK S.S. BOLT AND CHANNEL NUT SPLIT WASHER S.S. LAG SCREW WITH FLAT WASHER SNAPNRACK 2.5"MINIMUM EMBEDMENT STANDARD RAIL - 1S STANDARD i SNAPNRACK COMPOSITION ROOF FLASHING STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. o,. ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3"USING UP TO TWO LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION RAFTER TYP. MAINSTREAM 5W� ENE GY CORP DESIGNER. 0 AdP[Neteu SCALE DNS PART NUMBER'. DESCRIPTICN REV R , uRn_�ER o Rye, 5700 PEN 007 PEN DETAIL 01,FLASHED L FOOT TO C FvagwnLPrvf7U%Zftom .,..: . --.:_, .: APPROVED BY. DATE' 120113 RAFTER CAMMING SEAM CLAMPS ARE REVISION SPECIFIED WITH A BLACK OXIDE STAINLESS STEEL BOLT. IT IS IMPORTANT TO USE THE PROVIDED BOLT AND TO TIGHTEN TO 16 FT-LBS FOR FULL LOAD CAPABILITY CLAMP CAN BE USED TO SECURE RAILS OR DIRECTLY SUPPORT SOLAR MODULES TO D TERMITO E BOLT SIZE TOP WITH MODULE CLAMPS OF THE CLAMP(X)AND ROUND UP TO NEAREST�"BOLT SIZE L FOOT OR SIMILAR TILT BRACKETS CAN BE ATTACHED TO THE TOP OF THE CLAMP AND PROVIDE A MOUNTING POINT FOR RAILS OR OTHER 3: BOLT IS STRUCTURAL MEMBERS TIGHTENED, SECURING CLAMP AND L ❑TORQUE BOLT I FOOT AT THE TO 10-16 PT-LBS SAME TIME "X.. SEAM CLAMP BASE (STD BASE SHOWN , BUT INSTALLATION 1 OF WIDE BASE IS - SEAM IDENTICAL) ' CLAMP - .. .9 CAM 2: OPEN i CLAMP GETS 1: INSTALLATION STARTS SEAM LOWERED .5 TYP. WITH CLAMP IN CLAMP ONTO SEAM OPEN POSITION THREAD WITH BOLT LOOSE INSERT 1 2 3 ❑ 1\1c •. .,fEAEN MEROY CO RP. DESIGNER: GMWPWmem SCALE: DNS PAR!NUMBER', DESCRIPTION' REV MAINS `^•- •^ -- "" OHAFIER SIDO PEN 004 PEN DETAIL 04,SEAM CLAMP F ` TC'%L!1714DT�1•°13%M J= APPROVED RY^=-:-"T�.`"..••._.•..•••,.•; . DATE: L 120113 11Y INSTALLATION OF NEW ROOF MOUNTED BAYVIEWAVENUE* 2.6kW PV SYSTEM 42 BAY VIEW AVENUE SALEM, MA 01970 I6 dl Revlon. VICINITY MAP SITENp' R'Ef.1Y1gi, $f..ALE NTS Prpieq Tiue:p "' COOK.R09ERT 214ITYANCT pIFIS72 J Pro CrA AEtlrnsv 93 BAV VIEN/AVENUE � SAL[M,MA IIIJIII SHEETINDEX x IN LITENEOTFLEINFAINNINI Pi COVER SHEET WI SITE INFO&NOTES rE r,< D s ,E I" PV-2 ROOF PLAN W/MODULE LOCATIONS vRovoseo z.cKw IF,, L'I'lli"ITITTELL "I ILIETL ANTE Ta 111,I Rm,ImG.-Cx reTEII TT i PV-3 ELECTRICAL 3 LINE DIAGRAM MINE solAR sysTEM INTENT 040L111OLITTEMIEFEVIEDID S NEAI D,".�I�NNI_TTL Oir. OOLI F F ELIET GC \NA-COn,Mrgr1B E.NS.1r1.N \Its. OOe IV -IONSLELCTTO.D-APT 0.- LIT 1.1,111111JE,.r a6P $SrOrn lnlprm340ni C 1 q '0' SE,- IN ,.1111..TEDT01. B EL CO O 6 UFne IN�TEN ELL41 0 NFILD)m.4 GAye ED 6, SLLS.SITETv ANDATED,ENTITLEDODO .xuna00lwr ups-- a.ra.T Cx _ ..el, I"o:inD. a rvL. ,ouNm.A M11INION FIT, co THE o.E INEEM o uawTLI n -o "o oR c - c °M NI c 0 p TINFIE,' p Rcv Np $M1NDI V 4 0 P Si 0 = n Li I LDI.N 011 ELFIFILLIAL IF TINE p r �NAEMT LLFETNIN—NI KTEeN ,r. 1n N 5. r p N CHD BE LITIBINIII III NATION. u DIT G: ,TCLCR>E m NIT FELL)I III MINDEF ,INKLIT pSo rONA ED E GENELEGENI SOLAR i.Erl UN.w N itEU4AI -r nI: ..E 0NEv n!..".11131 IL AN 40' 111 LOT ANDET.A Ill.:I IN T" II:.p.F'.T N"i[DID TO A.11FLITY Or F01: \G'NT. N.nwe�v Ll. TI s d o.,.,, ANownxuiRT ve pnL tPc'mio a m I.ARN000LE 101AR ne 11'111E _ _____ __ ERINC ETTER FOR SaKlru R 0' IYv..nl q - V,- 1 FINE L FS ASPHALTSHINGLES van oo nPSHI o AYFIl FOR s-111111 GT ,v- csE111TT c IAL ore A a AVY " GAVE AN NOEG.ES SNLI+m -P E TING RA TEH DREELOEPY HNGI T �P �+ , 1 Ir[ IIEFER 9ICP SPEIENI E EA"A nATfPGHMENTd f.LIP DETAIL FEELLEFOE NLy f]PV MOO'JLE ATTACHMENT ON ASPHALT G111N<.LE ROOF TP.913HTFRGM GROUND LEVELTG PEPN OF ROOF ilscnRsrnm iu sHt. 1 1FR IFE.,11 HFGFTn 11gcu-rvon�s,..e awT[m°nosuLn ALPHA 1GDVLeGu.1[r,Hmrs Issun,ll RUJ n0. IrnN �rojoal Tue: SNE COOK,ROBERT rv�uln Warr»nysfineY Pra oa AtlrLoxs' � R� 42 BAY VIEW AVENUE SAL[NI,MA019I0 AR PAT r x fL I k € Y % Drav,�n rllln'. �1 F kFT k k) �<i PaovoseD zcfiw f F I // o j AT' �s,vmis 1 3r SORREL IOTOrI 55 :LIE LO P uD M , Dc 1.„Lr s��vxov, 4) ROOFTOP OLE INSTALSYMBN LE sn L.ow of ul�dr °e. IUP nllmc Rw.90. 4ALal IT AhiAV SCH OUSE 6YMtlOL LEGEpL��Y WILL NOF e%TEND BIEOYONO THE IXI TING BUILDING ENVELOPE � sacTcx._sra.ercr..,Pu o.ul. PLUMBING SCHEDULE EOUIPMENr4G11 OI.Lt IL.EL HO NATRA u Ermr..� ® m'vUFAL ° A nn WI 11APARtot) S RES NEELFNTO THE ORRYO E SE)IWA-II) E All" NFL „ _F L RIF ISLE OF TO IFFIL-111H'FIT �9 IF p,HER O65iRUCTIDNS souueOOENli r06 i- T o,TS, I �. 0 FAT ROSE ,y AL FLAMIT �Y� FRT1-11211, I] A L ] �� • — n i .w... y 1 u: Engineer I UCCIPS Holder: MopxreD UNDER SOLAR MODULE S,VVA m40U`[S uD LI FIFPITeM[GXAl"I M4eUE r5FAAI .]S NEC 690.34 P4GMoxPFNVVING 1 SIPIN IPIETIII INLViXS'-15nv.iu. NFE ___________________________________________________________________________________ i - JVN[DON --I l t Ili /r II I I IGANEdIFo 3i4ns I I I I xU Ut5 PTJOS,Title COOK,HEBERT PAY CIRCUIT wl IRINDI AOQ:.111117111 oncu6LartX doll NEC r WCI RECEPrNED PmIOGr AdI L)LDALST CXPECIED AMBIENT THETCHANRE BASED ON EXISTING- H SA N C. SHRAE MINIMUM NEAR Ex1RENE DRY NUM 120/2ADV 2.1 TF/1 NM C. IEMPCRAIURE FOR ASHRAE LOCATOR MOST SNIT.ID uTUtY � 2GDA MAIN RREAKER rP I 4:BPVVIEWAVENUE INITILAWN LOCAL➢ON. LOWEST EXPECIEG.w9EN1 EWN 4COA Burode SALEM,MA U1910 TEMP=-IGCF _2.)HIGHEST CIXJIIXUWS AMBIENT IEMPEPANRE BASEDON PARRPE HIGHEST MWM 2S DRY BULB xrawln Tlln:„MPEPPWDE FOR PSNRPE LOCAIGH MOST SMILAX TO T LOCKABLE 611 SLpLLATIW LDCATON. HIGHEST CW BNVDVS TEMP oSCGR EC FUSED W/ 3AEJ 20A FUSES PPUPUSEU2 6AW 1)2SE DO NOT MGEED 4JL A cETD PPCOULTON SOLAR SYSTEM GPoVPED W/N AIR YlA UN U TEMPERATURES PW5 PSVRAE NOT EXCEED 2S NE9XW BPEANE END CE 1EP DS[dNE E UEBB T 2 W 2.DV�p� � D fl AND DSIN PFNF,E MTH DNGRIXINDED r--- C- --Y%-_ B B �a0000a - -v lQI PiJ J sSI,d HI )O STAINS PALM INIE.s, N s CHI1 FLR LESS TXAx D 9 GE MOUNTED CARRYING GpRDUCIAT IL ' RCQG MOUNTED THE CREDITED CONDUIT DESIGN TEMPERATURE 0.5'ABOVE 1 ,-4UIs j TIE OUIDOCA DESfN FNPEPPIUPL J HE 47C ON LESS(ALL OE UNMED STATES), l- 7 0 1 PHOIOWLTAIC PONER SYSTEM$SHALL BE rr P IRG_TD O PON B•rDrinad4n PXOTOV—"0 SOURCE AND WTPUI CIRWIT AS PER y �: - - I//•T (GR'I SvtR[In Vui ]44W .PC ssoas VT'Y EARTHS MAIN BREAKA ED)I SDUARE D SCLAPE D J mul Vere'll-r4l: u 5.)All EQUIPMENT INSTALLED OUTDOORS STALL HAVE y CENTER INSULATED LINE TAP$ �PN. D22RN ON, pRRR0.B ________J [ei ir.IXnt[VI A x[u]RAnNG. INSTALLED ON MPIN FEEDERS .. NEC 690.64 Unun min Pxr. .IT I Awns xT CANNYTN6 x..CAMPS 6 REWIPER CCNDVCiOP AMR UAMPACITY PER STRING NNGVA (nee AMa.atmuT)psaa•T.zs)I -Ie.1Bn pco�irvs,o: AEG YIp ow R. ERIH EY �' A BENT TEND 55 ,, END DCMTING FACTOR, IS I PACE Y LEP TNG-2 COG OD (o]B)uG SOIN Rev Na. Shxl aI 30.OG fl 5 MERSFgRE MRE 4ZE 5'ALL TOTAL REQUIRED OXIMM Cq PYPAGTY M I 14.GGA'I 25- TENA PRO nG DERATER AMPACTY ', AMBIENT TEND: ]DL TEMP DERAnxG: TO xI-s PY s ARACE M!17V DERPnxc S J GAS: N/A •r' 9M•I e-WA 9M'R�`TF THEREFORE Q IR MPE SZE I VALID l cuAL DRAWN wP RREMI 14 ON PPmecnon W SOLAR . TOTAL Ezz�PExr: acA IwI,FOR.w.-x r. lu ss I,�x�,. .AG -->zpA cWacuRRExr PRorecnox Is vnm Inm. Al ':'eLN.o,..,.,nme