Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20 ABBOTT ST - BPA-14-1924 SOLAR PANELS
' - I �l -19 2 c� �� `+ oz� ��03 . � The Commonwealth of Massachusetts RECE'IV� c�Tv oF IN PECTIONAL:' Board of Building Regulations and Standards . Massachusetts State Building Code, 780 CMR� SALEM ,i � RevisedMar20// . Building Permit Application To Construct, Repair, Renovate Or Demolish a 14 OEC 15 F One-or Two-Family Dwelling . .� This Section For Offici Use Only NBuilding Permi[Number: Dat pplied: � �„� / /�/ \i Building OfFcial(Print Name) Signature Da[e SECTION 1: SITE INFORMATION ' 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers � � 20 Abbotl S� 10 0138 l.la Is this an accepted street?yes no Map Number Parcel Number v 1.3 Zoning Information: 1.4 Property Dimensions: 1 RESIDENTIAL � Zoning Dist'rict Proposed Use Lot Area(sq(Y) Frontage(R) 1.5 Building Setbacks(ft) Fron[Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Priva[e ❑ "Lone: _ Ou[side Flood Zone? Municipal❑ On si[e disposal system ❑ Check if yesO SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Record: � � GeoRrey Millar SALEM,MA 01970 Name(Print) Ci[y,State,ZIP 20AbboltSl (978)210-]81� geoffrmillar(]gmail.com - No.and Street Telephonc Email Address SECTION 3: DESCRIPT[ON OF PROPOSED WORKZ(check all that apply) , New Construction❑ Existing Building ❑ OwnerOccupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other ❑ Specify:so�na av B�IBf DOSC�IPTIOII Of PI'O(1050(I WOIICZ:�NSTALL SOLAR ELECTRIC PANELS ON ROOF OF EXISTING HOME TO BE INTERCONNECTED WITH HOMES ELECTRICAL SVSTEM. SECTION 4: EST[MATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials I.Building $4,000 �� Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $10,000 � Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5. Mechanical (Fire $ . Su ression Total All Fees: $ � Check No. Check Amount: Cash Amount: 6. Total Project Cost: $ �4�000 � ❑paid in Full ❑ Outstanding Balance Due: 1�1�� l��o I Z� I'l • SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) � 10]663 B/29/2017 SOLl+RCITV CORP./CRAIG ELLS LICEt152 NUmI10E N.XPIfa[lon D3$ Name of CSL Holder . List CSL Type(see below) � 24 ST MARTIN DRNE BLO 2 UNIT 11 - No.and Street � Type Description U Unrestricted(6uildin s u to 35,000 ca ft. MARLBOROUGH,MA01]52 � R ReS[�ICl2d1�'ZF3mi� DWe��ltl CiTy/Town,S[a[e,ZIP M Mason � RC Roofin Coverin WS WindowandSidin � SF Salid Fuel Buming Appliances 918-8]5-1698 CELLS@SOLARCITV.COM I Insulation Tele honc Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) . 168512 3/8/2015 SOLARGTv CORP. HIC Registration Number Expira[ion Da[e HIC Company Namc or HIC Registran[Name Boo Researcn Dr ablanco@solarciiy.com No.and S[reet Email address wnmingmn Ma.m88� 9�8-215-2383 Ci /Town,State,ZIP Tele hone SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit mus[be completed and submitted with this applica[ion. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavi[Attached? Yes .......... C� No ...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize soiarcnyiasv�a sia�oo to act on my behalf, in all matters relative to work authorized by this building permi[application. ' 4SrF n�frL'<C�� �znvzoia � Pcin[Owner's Name(Elec[ronic Signatucc) Date � SECTION 7b: OWNER'OR AUTHORiZED AGENT DECLARATION By entering my name below,I hereby attest under[he pains and penalties of perjury that all of the information wntained in this application is true and accurate to the best of my knowledge and understanding. A�S�lC� �`�I1(C ��� izniizoia Print Owner's or Autho�ized AgenNs Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permi[to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to[he arbitra[ion - program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.eov/d� 2. When substan[ial work is planned, provide the information below: Total floor area(sq.ftJ (including garage, finished basemendattics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be subs[ituted for"Total Project CosP' � � � � � • . � � . • . . • . . . . .� .. � •. � . . ..- . . . . .. . - . -. -. • �i• ��• . . .. . •.. - � � ... � ..- _ , � - - � . .,, . • • • . ..• � • � .. ..- •-. . - . .- . . .- . .. � • • . . . •-. . - • . . �- . - .- . . .. . . . .. . .. �• .. • . . � . - . . .. - • . . . ... . . .- . . - �- . - - . . - . -. -. .- � � -. . . �- . -.. . � . 9 ' � �- . i ' ='..- ,^.� :%, , � '� '�- �/;�. �;�f � -' Y �1 / ` , `'� �I � � - • � '. � - �`"'-� ,e .. �� d�na •� ` +'� N _� � c�`° ' \ ;;_ '"� � . St �Sirongwater, . ar�on _ .:— ' � �;v ' ,/"x '� ` �Brook �•;_ , . YGr �; � � . ,♦ �rt;4 �s �„� _�' .._� �;C _ ; °�e Rd ;. ' ♦ . ' sa".r , •%�,,,�',` N' J ! ���;� ` � . . y� ' .�' _a� �I � ` i.3:, � w �• } .;I �.� �+� •t ' '� Ab � 3 ��• e:l� ��L��� 1 �s . � +, 1 '' .`.., ., . ` -a � - . 1 ` � ` � Q t•� ,` � � `'� h / l � `'\"i �� 1�'. � � y�_ { � • '�� ` f � � � e �SfOJ! � + , '~ -` * -( • -� � � . � � � �� �• � ' �a � �. ,,: �� �� � � �� � � 1 . ; , •� _yz:� �. .,��o + , '- s'�`e �� ., �.�=� ' , Pbo; ., . �� -r , ;� o�. a ��.� , _ � , - . , o- '�( . � �,r'. : '( ` : r �e� " � . .�r . � �\ � �, 2 4^ � `� � � i � � .f�� �+i � (o k ° � ` . � � " .�' ! � ...�' F .• ''� a � � r � � � �' �` / ♦ �^'. �l J . • �,r; . '-�'�/' /�♦ ' `a ` ,, i a �, ; �w �j:^� �� . — i � '�`^ — ' AA,~ -� i� : - ' � ♦� � ��� F.� �� � � i] — . � � !I V� i . � � ��.�'�/ ��:• .� ~�� �` a '�,� , � ', � • .�� •I� o w. � "y � t �; .- . , � ) '� .r �rl� f . r� � ~ � � . �t ,4;1, r�e � i� �O— } �j"�a .'. T "y ; f.:rt st 0 � � J � ./ � � � � � � s���, ,� l J s r � t +� � ., .r{� #Y�^ ��`. ..�!�� . F . . . �R^r� 3 `=�.J �Y -„ �,t;' �� �F 1 � ` � `n �:�� _� e�� a �+�+ `h1� 4m` ....� Q :. . - t � '1� • b� ��.�,` , R` = �,,' Galfo s Hili Par�� � � - /t� ' ' " • \� } G� �„ a ' 7 •-_ 'l m f •,+�\ . • �r• ` ��• (� ��,I� '+..',`yF 'R� '°I . . .« .�� \ *4 ��'� „! . 17 �,''�+�; : Dt: i a`I��e�_Mass'GIS, C;ommonwealth of M'assachusetts EOE-A'...USDA Fann Service A enc � � � � COMPANY PROJECT � WoodWorks� SOFlWIYFfOY WOpO�[SIGN , Oct. 30, 2014 09:11 MP1&2.wwb Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit � , tern Start � End Start End � DL Dead Full Area 8 .50 (16.0) * psf SL Snow Full Area 28 .00 (16.0) * psf PVDL Dead Full Area 3 .00 (16. 0) * sf *Tributary Width (in) Maximum Reactions (Ibs), Bearing Capacities (Ibs) and Bearing Lengths (in) : 14'-11 4" 0' 13'-1.5" Unfactored: Dead 113 113 . Snow 246 246 Factored: Total 359 � 359 Bearing: F'theta 495 � 495 Capacity Joist 740 � 740 Supports 1052 . � 1052 Anal/Des Joist 0.48 0.48 Support 0.34 0.34 Load comb #2 #2 Length . 0.50* 0 .50* Min req'd 0.50* 0.50* Cb 1.00 1.00 Cb min 1 .00 - . � 1.00 Cb support 1 .13 1.13 Fc su 625 625 � 'Minimum bearing length setting used: 1/2"for end supports. MP1&2 Lumber-soft, S-P-F, No.1/No.2, 3"x5-7/2" Supports: All -Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 16"c/c; Total length: 14'-11.4"; Pitch: 6/12; Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help); WARNING: this CUSTOM SIZE is not in the database. Refer to online help. • � WOOdWOfkSOO SIZef SOFTWARE FOR WOOD DESIGN MP182.wwb WoodWorksO Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using Nos 2o1z : Criterion Anal sis Value Desi n Value Anal sis/Desi n Shear fv = 27 Fv' = 155 fv/FW = 0 .18 ` Bending(+) fb = 934 Fb' = 1504 fb/Fb' = 0 .62 Live Defl 'n 0.54 = L/327 0.73 = L/240 0 .73 Total Defl 'n 0.78 = L/224 0.98 = L/180 0 .80 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1 .15 1. 00 1.00 - - - - 1.00 1. 00 1.00 2 Fb'+ 875 1 .15 1. 00 1.00 1.000 1 .300 1.00 1.15 1.00 1.00 - 2 Fcp' 425 - 1. 00 1.00 - - - - 1.�00 1.00 - - E' 1 .4 million 1. 00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 320, V design = 299 lbs Bending(+) : LC #2 = D+S, M = 1173 lbs-ft Deflection: LC #2 = D+S (live) LC #2 = D+S (total) _ D=dead L=1ive S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output - Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 58e06 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F�theta calculated for each support as per NDS 3 .10.3 Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 4. SLOPED BEAMS: level bearing is required for all sloped beams. JI � ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALCY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB fIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDWG OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISi1NG. • NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECiION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED W1iH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT � ' 3R NEMA 3R, RAINTIGHT PVi COVER SHEET I ��� PV2 SITE 'PLAN PV3 STRUCTURAL VIEWS � PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES P�s THREE LINE DIAGRAM Cutsheets Attached ♦ GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION � � X. ELEC 1136 MR OF iHE MA STAlE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Salem REV BY DATE COMMENTS REVA NAME DAiE COMMENT$ UTILITY: National Grid USA (Massachusetts Electric) • S O e - .�D • . - • � � � - - • � - CIXJFlDFN7IAL - 7HE INFORNA7IW HEREIN ,qb NUYBER J B-019 6 7 0 O O �oxrax: oeunirnor�: ocsar. \� CONTAINm SHALL NOT BE USED FOR IHE �:•fi BENEFlT OF ANYONE E%CEPT SOLARqTY INC., YpIN71NGSY5TEll: . MILLAR, GEOFF MILLAR RESIDENCE Joe Selvaggio -- �SolarCity. NOR SHPLL IT BE DISCLOSED IN YMOLE pt IN Comp Maunt Type C 20 ABBOTT ST 5.61 KW PV ARRAY ���� PART TO OTHERS W750E iHE REqPIENYS Mo�S SALEM MA 01970 ORGANIZAlION, E%CEPT IN CONNEC110N N11H � 1HE SRLE AND USE Oi 7HE RESPECIIYE (22) CANADIAN SOLAR # CS6P-255PX 24 St. Mmlfn Drne, Buihmg 2, Unit 11 SOLARCItt EOUIPMENT, N17HWT THE NRITIFN �N��: PACF NANE: 91EEf: REV: DAIE 7; (650)6�38-1028 i:A(650 63B-102B PERMI550N Oi SOLARptt ING SOLAREDGE sEs000n—us000sNR2 � �978) 21�-781� � COVER SHEET PV � 10�29�2014 (eeersa-p�v(�u�2aes) m.adorcity.00m PITCH: 25 ARRAY PITCH:25 MP1 AZIMUTH: 71 ARRAY AZIMUTH: 71 MATERIAL: Comp Shingle STORY: 2 Stories �SHpp� PITCH: 25 ARRAY PITCH:25 MP2 AZIMUTH:251 ARRAY AZIMUTH: 251 �$� Y00 JIN � MATERIAL Comp Shingle STORY: 2 Stories K VI y No.4 Rl� Digitally gne y Yoo 1in Kim D a te:2 14.103 0 10:22:30 o -07'00' �' a 6 � Z�„ LEGEND � °"� Front Of House . (E) UTILITY METER & WARNING LABEL i� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS A � DC DISCONNECT & WARNING LABELS 0 AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS Inv � M -- � . �, � DISTRIBUTION PANEL & LABELS ..� 0 (E) DRIVEWAY � �� LOAD CENTER & WARNING LABELS ¢ � O DEDICATED PV SYSTEM METER N Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED �`` INiERIOR EQUIPMENT IS DASHED L1 J SITE PLAN N Scale: 1/8" = 1, W� O 1' 8' 16' E S J B-019 6 7 0 O O P�Ig��� OESCRIPPON: OE4GN: CONFlDENTIAL - iHE INFORMATION HEREIN JOB NUYBER: ���_� • CONTAINED SHALL NOT BE USED FIX2 7HE MILLAR, GEOFF MILLAR RESIDENCE doe Selvoggio �'���SolarCity. BENEFlT OF ANYONE EXCEPT SOIARqtt INC., MqIN71NG SYSIEY: � ��"F NOR 91ALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 20 ABBOTT ST 5.61 KW PV ARRAY � v,wr Ta oniErss ouisoe mE aEariaYs ���s SALEM MA 01970 ORGANIZA710N, E%CEPT IN CONNECTION VA1H � � 24 SL MartN DAre, �ildin9 2.UNl 11 1HE SALE AND USE OF THE RESPEC7IVE (22)�CANADIAN SOLAR # CS6P-255PX PA�N�, � g��; �µ pp7E; Morlborou�, MA On52 SOlARp7Y EOIIIPMFNT. N77HWT THE WRITIEN IN`hR7ER: F. (650)638-1028 F. (650) 636-1029 ' P�aMissoN av sav�aan iNc. SOLAREDGE SE5000A—USOOOSNR2 (978) 210-7817 SITE PLAN • PV Z �O�ZJ�ZO�4 (BBB}SOL-CI7Y(765-4A89) ....awo,��iy.�«� J NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER m f � � E WALL OR S 2z6 SPF 2 N SUPPORT BELOW _ (E) RIDGE BOARD � �7* MI OR SUPPORT BELOW * SIMPSON SDW SIMPSON SDW 22458 22300 WOOD WOOD SCREWS * �3,_2. SCREWS (N) SISTER MEMBERS (E) RAFTER (E) LBW - �1 SIDE VIEW OF MPl N,� 957ER UVpiADE INFORMA110N: RAF7ER UP(xtAD IN I A D BY HATCHING � N '-0" MIN.� UP(3iADE NOTES `\ " �r SEE MP SIDE VIEW FOR REQUIRED LENGT MPl x-svaar�c X{AMILEVER v-svaanG rt'aKn��a rvorrs �, WT AND ADD (N) SISTER AS SHONN IN 7HI5 SIDE NEW AND REFERENCED TOP NEW. uHoScsre 69° 24" STAGG£RED 2 FAS7EN (N)95TER 70 (E) MQABER W/ SIMPSON SDW 22300 QF 2-PL1� OR 22458 voarwr 48" 19" � (IF 3-PLY) S�W SCREWS STAC#RED AT 16� O.C. ALONG SPAN AS SPEQFlm, IF RAFfER 2x6 @ 16"oC RooF nz� n v�ra zs �Q�Es:2 WOOD SPLITIING IS �EN OR HEARD, PRE-DRILL 'M7H A y�' DRILL BIT. D 1 D 1 awuraz� n a=rcN zs q�7, ppnq� FOR NLL LENG7H NEMBERS ONLY- FAS7EN (N) 9DE MEM�R TO c�. zx6 @t6"oc com sn��ie MIR � , (E) RAFfER W/10d QF 2-PL1� OR 160 FR01A EACH 9DE QF YPL'Q COMMON - NAILS AT 6' O.C. ALONG SPAN. •SISTER ALL RAFIERS ON THIS MP SECTION INTO WHIq1 1HE�ARRAY IS LACGED �SH�F �,� TOP VIEW OF PARTIAL LENGTH LAPPED SISTER �F�'- Scale: 3/4"=1'-0" �� Y00 JIN ' K � 1 g No.4 7 PV MODULE µ. 5/16" BOLT W1TH LOCK INSTALLATION ORDER Digitally si 00 Jlll Kllll & FENDER WASHERS LOCATE RAFTER, MARK HOLE 6" END Date: 2014.10.30 102237 -07�00� ZEP LEVELING FOOT ' (1) LOCATION, AND DRILL PILOT DISTANCE X�-6"�`16" O.C. TYP.�' (E) 2x6 RAFTER ZEP ARRAY SKIRT (6) HOLE. I I ' �4� �z� SEAL PILOT HOLE WITH POLYURETHANE SEALANT. 2 4� ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER (E) COMP. SHINGLE ��� (4) PLACE MOUNT. (E) ROOF DECKING U �2) � INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) �5� SEALING WASHER. �� 2x6 END FASTENER GROUPING WITHLSEALINGOWASHER LOWEST MODULE SUBSEQUENT MODULES �6� INSTALL LEVELING F00T WITH V 1 Scale: 1"=1'-0" (2-1/2" EMBED, MIN) BOLT & WASHERS. �E� RA"�R STANDOFF � `�1 Scale: 1 1/2" = 1' CONFlDENIIAL- 7HE MFORMAlION HER�N �N�Na�: J B-019 6 7 0 O O 7Rp16E OYMER: U6CPoP710N: DE9(d7: \\, CONTAINED SHALL NOT BE USED FOR 7HE \��}r BENEFlT OF ANYONE E%CEPT SOLqRCItt INC., YWNIINC SYSlE1k F MILLAR RESIDENCE Joe Selvoggio -- �SolarCity. NOft SHALL IT BE DISCLOSED IN WHIXE OR IN 20 ABBOTT ST '"" PART TO OTHERS WiSIDE iHE REqPIENYS Comp Mount Type C 5.61 KW PV ARRAY ►i� oRcnniunorv, �ccFrr iN coxNEcnorr w�ni uaou�s SALEM, MA 01970 1HE S�1LE AND USE OF 1HE RESPEC7IVE (22) CANADIAN SOLAR # CS6P-255PX T4 SL Nartln Drive, Bu6mng Y, Unil 11 SOLARqtt EWIPMENT, N17HWT THE WRIT7EN w��� PAGE NANE SHEET: REY. DAIE T: (650)6�38-1 2B i:A(65D)638-1028 r�eMis�orr ov sanRan iNc. SOLAREDGE SESOOOA—USOOOSNR2 (978) 210-7817 STRUCTURAL VIEWS PV 3 10/29/2014 �eee�-sa_arr��es-z+e9� ....ea�nY.� NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER u * (E) WALL OR 2x6 SPF�2 (N . , SUPPORT BELOW (E) RIDGE BOARD 5 �1c M� ' OR SUPPORT BELOW �ir�7'} * SIMPSON SDW SIMPSON SDW 22458 22300 WOOD WOOD SCREWS * SCREWS (N) SISTER MEMBERS (E) RAFTER (E) �W . 13'-2' B SIDE VIEW OF MP2 NT5 4S7ER UPGRADE INFIX2MA710N: RAF7ER UPGRADE INDICAIED BY HATCHING I �—O" MIN.—�i uvicenne nohs T SEE MP SIDE VIEW FOR REQUIRED LENG Mp2 x-srnan� xusm�a v-srncwc vurm�eim r+ares 7, CUT pND ADD (N) SIS7ER AS SHOWN IN 7HI5 SIDE NEW AND REFERENCED TOP V1EW. � urvosvre 69" 2q" STNGGERFD 2, FA57EN (N) SIS7ER TO(E) AIEMBER W/9MPSON SDW 22300 QF 2—PLI� OR 22458 • voalwur 48" 19" QF 3—PLY) SDW SCREWS STACGERED AT 16� O.C. ALIXJG SPAN AS SPEQFlED, IF naFrEa 2x6 @ 16"oC aooF nz� zsi alrcH �s �aR16:2 �D SP11T71NG IS gEN OR HEARD, PRE—DRILL YA7H A }�' DRILL BIT. D2 D2. aaanvu� zst acr[ry zs p�T. OP710N FOR NLL LENGIH MEIdBERS ONLY— FAS7EN (N) SIDE AIEMBER TO . c.�. zxe�is'ot wm snm ie MIR - - (E) RAFfER W/10d (IF 2—PLY) OR l6d FROM EACH SIDE (IF 3—PLY) COMMON . � NAILS A? 6' O.C. ALONG SPAN. ` •SIS7ER NLL RAF7ER5 ON 7HI5 MP SECTION INTO WHICH 1HE ARRAY IS LAGGED . - U2 TOP VIEW OF PARTIAL LENGTH LAPP�D SISTER Scale: 3/4"=1'-0" 6" END ��tH�f DISTANCE „�_�6" O.C. TYP.—�' (E) 2x6 RAFTER � Y00 JIN , � � � 2��� — No.4 SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER AL� Digitall y Yoo Jin Kim Date: 2 14.1030 1022:42 -07'00' D2 2x6 END FASTENER GROUPING Scale: 1"=1'-0" PRE415E OMNER: OESptlPPON: . . DE9Cdk CONFlDEN➢AL — IHEINFCRMATIONHER�N ,pBNUNB�C JB-019670 OO � Joe $C�VO 10 +�,S+SolarCity. WNTAMED SHpLL N0T BE USED FOR lHE MILLAR, GEOFF MILLAR RESIDENCE 99 .BENEFlT OF ANYONE E%CEPT SOLARCI7Y INC., YWN7ING SYSIEIk � � /�� NOR SHALL IT 8E DISCLOSED IN WHOLE Oft IN Comp Mount Type c � 20 ABBOTT ST 5.61 KW PV ARRAY PART TO O7HERS W151DE 7HE REGPIEHYS ORCrWIL1T10N, EXCEPT IN CONNEC710N N17H W�U�S SALEM, MA 019 . . - 2,S,. u�„,o,�, B�B„�9 2..��,�„ 7HE SALE M1D USE OF THE RESPEC7IVE (22) CANADIAN SOLAR # CS6P-255PX �. PA�N�E SHEET: REY. DAIE: Mmlbaraugh,MA 01752 saaaan eQuieuQ+r, x�n+our nic wRi�H I��R T: (650)638-1028 F: (650) 638-1029 � PERMISSION OF SOIARGtt ING SOLAREDGE SE5000A-USOOOSNR2 (978) 210—.7817 STRUCTURAL VIEWS PV 3 io/2s/zoia (888)—SOL—CI7Y(76`r2489) mw.ealarcitpcan GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) �8 GEC TO TWO (N) GROUND Panel Number:Murroy Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE #SESOOOA-USOOOSNR LABEL: A -(22)CANADIAN SOLAR CS6P-255PX GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:13 883 611 Inverter; 500'OW, 240V, 97.5%; w�Unifed Disco and ZB,RGM,AFCI PV Module; 255�234.3W PTC, Black frame, MC4, ZEP Enabled ELEC 1136 MR ` � Overhead Service Entrance INV 2 . Voc: 37.4 Vpmaz: 30.2 � � INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENiIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER � SolarCiiy (E) WIRING CU7LER-HAMMER � IIlV21't21" 1 200A/2P Disconnect 5 SOLAREDGE - a A 1 oc. " � SE5000A-USOOOSNR2 oc ---__-MP 2: 1x10 (E) LOADS g ____________ ecc u aov r_____"__ ________ __ _____ ~ I I � �z oc, � i - 30A/2P " � oc � 3 z � ____ GND _-_'_ __-__ -EGG --- DG oG � . m e cEc �N oc oc- MP 1: 1x12 � l� �I . GND __ E�___ _____-___ -___________ ___F____ __ EGC________________i 1 I - N i . (1)CmduH Kit; 3/4' EMT - _'J � EGCIGEC � - -1 z I ' � 1 � I � GEC 1 �_ _T-T TO 120/240V � � SINGLE PHASE � � i i UTILIN SERVICE i i � i i - i i i i i i i i �� PHOTO VOLTAIC SYS7EM EOUIPPED Wlhi RAPID SHUTDOWN Voc' = MAX VOC AT MIN TEMP OI (��MURRAY B MP230 PV BACKFEED BREAKER B (1)CUTLEN-HAMMER /DG221URB ^� A (1)Sda,Cily/4 STRING JUNCTION BO% DC Breaker, 30A/2P, 2 Spaca Disconnect; 30A, 240Vac, Nan-Fusible, NENA 3R �..� 2x2 S7RMG5, UNGUSFD, GRWNDED -(2)Ground Rod; 5/8"z 8', Copper -(1)W7LER-�1AMMER Y DC030N8 GranO/Neulyd Mk 3UA, General Duty(OG) PV (22)SOLAREDGE�300-2NA4AZ5 ' PowerBo: limizer, 300W, H4, DC to DC, IEP nd (1)ANG �6, Solid Bare Copper -�( 1)pound Rod: 5/6' z 6'. Copper (N) ARRAY GROUND PER 690.47(D). N07E: PER EXCEP110N N0. 2, ADDIiIONAL ELECTRODE MAY NOT-BE REQUIRED DEPENDING ON LOCA710N OF (E) ELECTRODE O� i AWG B10, 7HWN-2, Black T 1 AXG /10, THWN-2, Block Voc* =500 VDC Isc =15 ADC T 2 AWG /10, PV VARE, Black Voc° =500 VDC Ix =15 ADC �gF-(1)AVlC 810, 7HMT!-2, Red Olo�(1)AXG i10, THNN-2, Red Vmp =350 VDC Imp=8.63 ADC OI�(7)pW� 95, Solid Bore Copper EGC Vmp =3$0 VDC Imp=7.19 ADC . . . . .�L(1)AWG�10. THWN-2, While NEU7RA� Vmp =240 VAC Imp=20.83AP.0 . . . . .�L(1 A'hG/10, 1HNN-2. Grem. . EGC. . . �'-� . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -(1)AWG 88, THYM-2..Gr.eeq . . EGC[GEC-(7),C,ondu,it,Ki4,3[4' EMT, . _ . . . . _ , . (1 A'hG/10, 1HXN-2, Block Voc* =500 VDC Isc =15 ADC (2}py(� �q py µ�RE, Black Vot* =500 VDC Isc =75 ADC . O � (1)AWG/70, 7HNN-2, Red Vmp• =350 VDC Imp=7.19 ADC O�(1)AWG /6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.63 ADC . . . . . . . . (1�AWG/10. 7HNN-2, Graen EGC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONFlDENIIAL- iHE INFpWA710N HEREIN JOB NUYBFR J B-019 6 7 0 O O �g�� DES7tlPPON: DE9GN: \\, CONTAINED SHALL NOT BE USED Fpt IHE ��d • BENffIT OF PNITMIE EXCfPT SOLANptt INC., NWNPNG SYSIEN: ' FF MILLAR RESIDENCE Joe Selvaggio �' `SolarCity. � NOR SHNLL IT BE DISCLO$D IN YMOLE OR IN Comp Mount Type C 20 ABBOTT ST 5.61 KW PV ARRAY - �►�� PART TO O1HER5 Wi51UE IHE RECIPIENYS uoou�s: . SALEM MA 01970 ORGANIZA710N, IXCEPT IN CONNEC710N N17H i � 7HE SALE AND USE OF 7HE RESPEC7IYE (22) CANADIAN SOLAR # CS6P-255PX � za u M�cm o��, e�aamy z, wa n SOLqRCItt EQUIPMENT. WITHWT THE NRIT7EN INYERhR PACE NAYE: . SNEEf: �V: OAIE E (650)638-1028' MA(650)63B-10R v�isaaN ov saiaaan iNc. SOLAREDGE SE5000A-USOOOSNR2 �978) 210-781� THREE LINE DIAGRAM PV 5 io/2s/2oi4 (888)-SOL-pTY(76`r2489) ....��a.���%�� AU TI N - POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: . — INVERIER dc DC DISCONNEC SOLAR — � � � � PHOTOV�OLTAIC � � � � � , � � ON ROOF � � � � u u - ununr s�v�c� � SOLAR PHOTOVOLTAIC ARRAY(S) � L__________________________J PHOTOV�OLTNC BAq(—FED qRCUIT BREAKER IN MNN ELECIRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 J B-019 6 7 0 �0 PRElAISE ONNER: DESCRIPiION: DE9GN: CONFlDEN7IAL — 1HE INFORMATION HEREIN JOB NUMBFR: `N`''SOI��CI�Y CONTAINED SHALL NOT BE USED FOR THE -MILLAR, GEOFF MILLAR RESIDENCE Joe Selvaggio �_ , BENEFlT OF ANYONE E%CEPT SOLARCITY MC., �¶NG SYS7EN: - �j,� NOR 91ALL IT BE UISCLOSED IN NHIXE OR IN Com p Mount T e C 20 ABBOTT ST 5.61 KW PV ARRAY PART TO OTHERS W751DE 7HE RECYPIENTS N�� � SALEM, MA 01970 ORGANIZAPON, E%CEPT IN CONNEC710N Ni1H 24 St. Modin Drlw, Building 2, Unil fl 7HE SALE AND USE OF 1HE RESPEC11bE (22) CANADIAN SOLAR # CS6P-255PX - PA�N�E SHEEf: REY. DATE: MMboroug�, MA 01752 SOIARCITY EWIPMENT, N11HWT 7HE NRITIEN M`,ER7ER: . T: (650)678-1028 �: (sso) sae-iozs - � PERMISSION OF SOLARqtt ING ER SOLAREDGE SESOOOA—USOOOSNR2 978 210-7817 SITE PLAN PLACARD 10�29/2014 (aee�sa-air(�ss-z+aa) ....wa,�ar.<«,� . �' • � • . �' � . • X .� i .1' • � • WARNING PHOTOVOL•TAIC POWER SOURCE . � �,,w�s ,K �# �^�' � � , ' ��� �WARNING� ��� '' ;���'�� WARNING� "� ' ' •�' � � �Yr� ?�n6'��.a�3n's'i+97yuWa2. •�' Ty a • x �'�ya.� lss. +s x.a� Fa��� •�� ¢4`k�i. T� ;,;,� .� u' ^"` .c. Ksa� �.� A ,.,ELECTRIC SHOCK HAZARD}y .,,. �.� ,� '�'E�ECTRIC SHOCK HAZARD�,L��ti�'�.� ,� �DO NOT„gTOUCH TERMINA�S r ,� ; �THE DC:CONDUCTORS OFy,THIS;�-� -�- • . • :TERMINAL�'S-ON BOTHTL"WEAND "? PHOTOVOLTAICSVSTEMARE ��'� � � � PHOO TOO VO" LTAIC 'DG�� � "LOAD„SIDES�MAY,BE.�NERGIZED .�,�'', ���.�"� �;�UNGROUNDEDAND�+' u "'�� � �„1y„y,,;ti,�4,,,,�,,,,,. ., �� .� INTHE'OPENPOSITIONx * � ,x3 YMAYBEENERGIZED` �,� ' �� � � � DISCONNECT j� . . .•� . ..- . . MAXIMUMPOWER- •, • • .,.�2:WAR} N�,IN2� G,�,���2' �� •� � ��db�h'x t' ^a, ..t J' k -�l.'i; � •�• POINT�CURRENT�(I�mp)_P' - ��- INVERTEROUTPUTz'�ef,�,�� � �,� � �'M�IMUM POWER'-T „�y;e' �*' �*�CONNECTION '����v� '� POMTyyOLTAGE'(Vmp)_� '�� r��DO NOT RELOCATE� dk���� ���—�—+-_-^� THIS°OVERCURRENT ra n � � MAXIMUM SYSTEM V �bEVICE . - VOLTAGE(Voc)_ "' ��r�`*-��3'CURRENTC(Isc)_A y'a. .5 .�- • � • `=PHOTOVOLTAIC�P01� T OFe"`,¢,p`� •• ,�_ � , � y:�,'��IN�ERCONNECTION ���^ * � ��_ � WARNWG�,"ELECTRIC�SHOCK � `�'��WA���N�� � � `dHAZARD+'DO NOT�TOUCH. ; '�� ' � EL�EC��TRI�C�ALrSHOCKHAZARD �. �� �?,xTERMINAL�S�TERMINALSON�' ' ' DO_NOT`TOUCH�.TERMINALS"'��'� •�� d.c,.BOTH�THE�LINEANDLOADSIDE � � . MqY BE ENERGIZEDvINpTHE OPEN TERMINA�SONBOTH�L'WE'ANOk:�� �; � � ,,,�� � ::;�POSITION7FORSERVICE.. '��� LOAD'SIDES�MAY�BE�ENERGIZED,. ";' DE`ENERGIZE BOTH�SOURCE IN THE�OPEN POSITION'� �. � - '� �,dm.� � ,�-Y ' AND MAIN BREAKER'�`�^�'+'� "� ;,,�'DC�LTAGEIvS 4r:- �i?� � ��W �PV,POWERSOURCE},i r,�� ^`ALN/AYS�RESENTWHEN v i^ .Z MAXIMUMAC��<Ta��'- ��'°SOL`ARMODUI,ESARE;, OPERATINGCURREf�T" A.'� "`EXPOSEDaTO SUNLIG,H�T,` �..��, ���:�MAXIMUMAC����� OPERATING VOLTAGE� ��"- j' �' r""i0.`e",'�,'���`t t "� a..� .�- • . • ' 3 �WARIVING�� xs � � � > ���� ���,e�� . .- . . . �,.��--� •- ..- ��� �_� � � -.�- �:�n�����, � � =�C/aUTION � �'� . -. a,w,ELECTRIC SHOCK HAZARD ; �.� �. r $ IF A GROUND FAULT IS INDICA,TED a ,�,,�.,� u ! PHOTOVOLTHIC SYSTEM ;H'� �� �NORMALLY�GROUNDED'� '� °i� CIRCUIT IS BACKFED"�`'" �� ' • CONDUCTORS�MAY BE�:^� sr:�� 5t,� ,�;i�„�;�„� �, :��,�.�F ``''" UNGROUN�EDANDENERGIZED�, . �r-"' �_ - ��°��^�-.�-�-.�-. � �„z,r. '�"� '.. :•r�'�:d��-.u."7�T�s� .�'x�'�'� *�r"c"�"�,�,,. s� -�- • . • u�'PHOTOVOLTAIC�QC�`� , '• • "�=-r` ou C ow R�s�o Rce �', •� ..- ' � • - �`_',t�'= �" �^" " -�� ��- � `" SECOND SOURCE'IS �; .� �, � • � �, , +.DISCONNECT �:� r� PHOTOVOLTAICSYSTEM , � � �� �k�' '�,'��`-"""�`'--°'t�� �� �S; �'�;s.a:}u��....z .a:_��s: �s.� n' � � � • � � � • - • • � � . " . + .. • '� < .r- • . • ' �: MAXIMUMAC `�� ` �� - -• . '• � � • - �, OPERATI�7G CURRENT.�u �,'4, - ��- � � MAXIMUM'AC^ °� .� � OPERATIfJG VOLTAGE�'��t�. '� � �� �• • • • �i a , a._ c..... '�i.,'.'�T''Y.f�'�.��:w +. � � 1• . � �. .I 1 v � : 1 �• l�!�� I�IIIII�I���� :i 1 1�. !i' � ••� �' � 1 • 1 1 p�l �IIIIII�" lllll�� � 1' � 1 1 i' 1 �1 1 �' �' � I • ! ' 1 I� • �IIA�I(�fl'�Illl�l��illll'�IilRllillllil� 1 ' � i 1. i •i•y\1 1. •1 .•Y I � IIIIIIAI:� 1� III�I�IIILL��I����Illll�i�lllll�lli� _ .. - -. _ . . . _ . ._ - - . � _ . . 4 SolarCity SleekMountT"" - Comp 4 ' � SolarCity SleekMountT"" - Comp " The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 Iisted � .:•• � '` � Installation Instructions is optimized to achieve superior strength and Zep CompatibleT^^modules � e � 7 Drill Pilot Hole of Proper Diameter for aesthetics while minimizing roof disruption and . Interlock and grounding devices in system UL � O labor.The elimination of visible rail ends and listed to UL 2703 � - Fastener Size Per NDS Section�.1.3.2 mounting clamps, combined with the addition / , �,, 0z Seal pilot hole with roofing sealant � of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 � ��?, / as"Grounding and Bonding System" � 3 Insert Comp Mount flashing under upper to a more visually appealing system.SleekMount . _. \ � � utilizes Zep COmpatibleT"' modules with •Ground Zep UL and ETL listed to UL 467 as , '� layer of shingle � . strengthened frames that attach directly to grounding device Qa Place Comp Mount centered Zep Solar standoffs, effectively eliminating the . � � ~ i ��, need for rail and reducing the number of •Painted galvanized waterproof flashing � upon flashing . I Standoffs requifed. In addition, Composition .Anodized components for corrosion resistance O5 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this � with sealing washer. . system,allowing for minimal roof disturbanCe. � •APPlicable for vent spanning functions \ :�_ Q6 Secure Leveling Foot to the Comp Mount - ��"' ' using machine Screw _-- --------_�.^ —-----' --'—__- ---- � --� �� . ___� 47 Place module � � O Components � ��J � � � OOA 5/16"Machine Screw � 8 QB Leveling Foot � � QC lag Screw � �! . QD Comp Mount QQ Comp Mount Flashing C � � � � � ' � � { � . � ' _ -_ _:1. . =\� nr� '��IIi . /� + � �-��SolarCity f%�W ET� �< <�STEo „`SolarCity �,... o January 2013 Ho�r � January 2013 � _ . .. - _. � _ . . ___ . f � e�E ee,�g� \��i CS6P-235/240/245/250/255PX • N �o,gJ"g �r' Car1aC�IaC1SOIar Black-framed Bteak�h Electrical Data STC CS6P-235P C56P-2dOP%C56P245P CS6P-ISDPXCS6P-T55PX TemperatureCharacteristics � • _. ____.__.. ._-___._- NominalMaximumPower(Pmax) 235W 2EOW 205W 250W 255W • • � OptimumOperatingVOltaga�Vmp) 29.BV 29.9V 30.OV 30.iV 30.YV Pmax -0.43%PG OpllmumOperatingCurrent�lmp) 1.90A 8.03A ed)A B.30A B.43A TemperawraCoatticient Voc -0.39%/°C Opan Circvit Voltage(Voc) 36.9V 31AV 3]dV 392V 3].4V Isc 0.065%PC = � • • � ShoriCircuitCurrentQsc) 8.46A 8.59F 8]Cq 8.89A 9.00N NormalOperatingCellTemperature 45tp•p . MotluleERiciency 14.61b 14.92% 15.23% 15.54% 1SB5% Opere�ingiempera�ure -¢p'C-+g5°C Performance at Low Irrediance . � � Maximum System Vollage 1000V IEC /600V UL Induslry leading pe�fo�mance at low i��aAia�ion MazimumSeriesFuseRating � 15A environmenl,+g5.5°/modulee((iciency(roman ApplicalionClassification qassA Ifradlanceof1000W/m'to200W/m' Next Generation Solar Module '°`Ve'mie,a��e o_.sW (AM 1.5,25 C) weer S�a�eero*es�co�amo�s(S*c)ou.,eaie�ce an000wim',soecwm nM i s am�en iemperawre oi zsn NewEdge,[henextgenerationmoduledesignedformultiple - -� � ��� � �� � � � � - � Englneefing D�aWings NOCT� CS6P-235PXCSfiP-340P%CS6P-295P CS6P-250PXC56P�255PX rypesofmountingsyslems,ofterswstomerstheaddetl NominalMaximumPowe�(Pmax) 1]OW 1]6W 118W 181W 185W valueofminimalsystemcosts,aestheticseamless OptimumOperatingVol[age(Vmp� zzry n,av v.qv z�sv z�sv appearance,autogroundingandtheftresistance. opumumove.a�inqcu..entpmp) 62IN 6.38A 6.49A s.son s.nn . OpenCircuitVoltage(Vo<) 33.9V 34.OV 34.1V 342V 34.4V Theblack-fremedCS6P-PXisarobust60cellsolarmodule SnortGrcvitCurren[(Isc) s.esn 6.96A zoen �.ivn tzsa incorporatingthegroundbreakingZepcompa[iblefwme. u�ea,eo,meiopa,ao�gcen*emna,ew.a,o-,ea��a�o.oieaowim.0oaa��mnMis..mniamiemoa�a���ezoc, The specially designed(rame allows for reil-free fast w��a speee i mis � - installa�ionwith�heindusiry'smostreliablegrounding MechaOiCalData system.7hemoduleuseshighefficiencypoly-crys[alline CeIlType Poly-crystallinel5fixi5fimm,2or3Bus�ars KeyFeatures siliconcellslaminatedwithawhitebacksheetandfremed CellArrangement so(s.io) withblackanotlizetlaluminum.Theblack-framedCS6P-PX oimensions 1638x982x4amm(64.5x38.]xt.5]in) � - • Quickandeasytoins[all - drama[ically isiheperfectchoiceforcustomerswhoarelookingforahigh we�gm 20.Skg(<S21bs) red uces installation time quality aesthe�ic module with lowest system cosL F.om co�e. 32mm Temperetl glass Frame Material qnotlizetl aluminium alloy • LowersystemCosts - CanWlrooftop ,I-BOX IP65,3tliotles installa�ion costs in half Best Quality Cable 4mm'QECj/12AWG(UL),1000mm � • 235 qualiry control points in module production co��aca.s � • AesthetiCseamlessa � MCaormCaComparame ppearance - lowprotile • ELscreeningtoeliminateproducidefec�s StanEarEPackaging�MOEules�perPallet) pq �s I � wit autoeveingan a�gnment • Currentbinningtoimprovesystemper(ormance ModolePiecespercontainer(40fl.Container) fi]2pcs(90'HQ) � . • Accredited Salt mist resistant . ........ . . . . .. . . . . • Built-inhyper-bondedgroundingsystem - ifiPs I-VCurves CS6P-255PX I mounted,iPsgrounded BestWarrantylnsurance ,a�� � i „ , � i • Theft resistant hardware • 25 years worldwide coverage ' � � � � � � - ♦ � P � SeclionA-A I • 100%warranty term coverage � �� j _ � • Ultra-lowpartscoun[ - 3partsforthemounling • Providing[hirdpartybankruptcyrights ' I ' + t 35.0 I and grounding system • Non-cancellable �-" . I e I • IndusUy first comprehensive warranty insurance by ' �mmediate coverage I��I �• . � AM Best rated leading insurance companies in the • �nsured by 3 wodd top insurance companies ' ', ' N j " . world i —�-� " �� E I ComprehensiveCertificates I ° _�m� = 1—�= i • Indusiry leading plus only powertolerence:0-+5W ! ' —,�T,i , j—ss° � • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, I a n 115 �o • Backward compatibility with all stanAard rooftop and CEC Listed,CE and MCS . + � -- r �. �-� , , � � � , _. � + i ..�. �. .. " � - . .- .. _� . .•� ground mounting systems • IS09001:2008:Quality Managemen[System �� - ��� ��„_„�,,.., ..'°"0'T"'.,..f,..—.,,a • ISO/T5169492009:Theautomotivequality •spe��n�e�m�s��cwnea'inmisaeiesnee�eresueiecimcnenoowimoucprmr�orce. � • Backed By Our New 10/25 Linear Power Warranty management system Plusouradded25yearinsurancecoverage • IS014001:2004:Standards�orEnvironmental AboutCanadianSolar . management 5ystem Canatllan Solar Inc. Is on¢ of the world's largest solar Canadian Solar was fountletl in Canada In 2007 and was � 10y�x qd • QCOBOOOOHSPM:TheCertificationfor companies. As a leatling vertieally-iMagratad succassfully listad on NASDAQ Exchange �symbol: C514) in tlatlValueF�om HazardousSubStancesRegulations manufaclurero(ingots,wa(ars,calls,solarmodulasand November 2006. Canadian Solar has module manufacturing sax Warrap�y solar systems, Canadian Solar delivers solar powar capacity of 2.OSGW and cell manufachring capacity of 7.3GW. , • OHSAS1800120071nterna[ionalstandardsfor products of uncompromising qoality to worlawide �� � eax occupational health and safety euslomars. Canatlian Solar's world class team of �, °X REACH Com liance prov de1them wHh solutions foral'It h¢rsolar ne dsrg to . s_. iu .. �s _..su .._ss ' P I _ . _' ' ' ' I •10 year product warranty on materials and workmanship a dt ,?,�� �$+p•`c^1 � ``,aE�1 = :� •25yearlinearpoweroutputwarran�y O�l� v��" \� ��ryv'����� :: ' www.canadiansolar.com EH-Rev 1�.1]CapyrlgM a tD13 CaneElen Sala�lne. . solar " • • � solar — • � � SolarEdge Power Optimizer Module Add-On for North America � P300 / P350 / P400 � � SolarEdge Power Optimizer _ � v3oo P350 vaao�� (fo�60.reIIPV �fo�)AreIIW (fo�9FceIIW Module Add-On For North America mo,�,.., maa��e., moa��e„ P300 / P350 / P400 • <��,>ur .: ;r : , _ � ,;, -:. ,. , � .; �, s �,. , , ; Ratetl Inp [DC P et^ 300 350 400 W . _ Absol � M muminpu[V II g (V callow t[empe�a[u�e) 48 _ 60 80 Vtl< - . MGFTOperanngRange _� 8 48 .. 8 60 �8-80 Vdc � . Maxim SM1 rtC uilNrtent�lsc) 30 f�d[ Maxim moClnputCurrenl IIS Ftic . MaximumEficen<Y ... ._.. .. ......... 995 ..... �.. .. A.••'#� " WeidbtetlEficency... . ... _..__. 988 . .. �... .._. _......... ...._........ . .._.. " Oeervoltage Category II !OUTVUTDURINGOPERATION�VOWEROPTIMRERCONNEQEDTOOPENATINGINVERTERIu �-�� � _ Maxlm O[p�Currenl 15 Atic .... ........ ..._ .... ...._.. _ ........_.... ..... Maxi O tp�VOIWge 60 VEc �' � OUTVUTDURINGSTAND6V�POWEROPTIMRERDBCONNEQEDFROMINVERTERORINVERTEROFF���' _ '. , fry p I� erPowcrOO�m�e � 1 ��Vtic STANOARO COMPIIANCE � -� � '4 EMC FCCPah]SO B IEC610C0631EC610066d � ` � r ��� � � . .... . .. .. � ""' ' �-� iecsuo9i�i ssuser ry) umai � SefelY ._ _. .__ �. ; . .5 ___ ._.. _. Yes 1 .. . .�NSTALLATIONSFECIFICATIONS__. . ". . . . ._.._ . , . ..", �A Maxi All d Syste V page . 3000 Vtl[ , mmc s�wx�.xj ia�xziz=aos/sss.a3axiss mm/�i�� .... .. _ . ...... we�em�' wdmgcaeies� sso/z.i er/ie � . �inpukonne�ro,......... ..... ..... mca/ampnenoi/rym ... Ou[p IW Typ /C nnecmr 0 bl I ula[ed;AmpM1enol '', .. .. ..._ __ _._. OutputWrelengt� 095/30, I 12/39 m/h . OOe�O &TmPea[ureRan6e ....... __... __.. d0a85/-00 +185 'C/.'F.. � Pm[ecLon PaMB.___. ._.__.... .__.. ...._....... IG65/NEMA4 ._... .. - .. RelanveHumdry_... .. ..._.._.. ......._ _.......... � ]00. ._....._._._ %._._ I � _. wmmesrtw.noim=�ew�.mmm�a.o�e.s�w=nm.�..�.no..w. II . �PV SYSTEM DESIGN USING A SOLAREDGE '�'„'• ' � " THREE PXASE THREE VXASE ^ n ��n . � �II ' ' �INVERTER t� . SINGLEPHASE 2WV. ` 980V . ' , PV power optimization at the module-level �M��� s� s�=�a�n�P oon _i , a io ia ' \ Mm mSttngLeng[M1�V erOp9miers) �5 35 50 �� — Up[o25%moreenergV Mai Oersning mvowe. _ nm eoao mso w _.... - Superiorefficiency�99.5%) parall Ist gsoroiHere uenqoM1so.orie�xano�s vez - MiHga[esalltypesofmodulemisma[chlosses,fmmmanufacturngmleranceropartlalshading ������- ������������� -�--�������� � - Fleiblerystemdesgnformaimumspaceuhlizatlon ' - Fastlns[allabonw[hasinglebol[ � �^;.��� ��r' '��� � - r""4*' �:t•�r�W'""'� �' '�.." ` an ':'�� - Nex[generanon md nf¢ndnce w Lh modolP I¢V¢I mm mring i R ,�p4`,3n,m� 'a" � Module-IevelvolWgeshutdownforinstallerandfirefigh[ersafe[y �h�.�;i�"��'� . . . . . . . �r:us"w� . � , . ' _ ���� ' . USA - GEPMNNY - ITALY - FRANCE - ll�PAN - CNINP - ISRNEL - AOSTRALIH WWW�SOIdfPfJgP.OS � R+� .;��'F ,�c$� AFr �' A ' solar ' • • ! Single Phase Inverters fo� Nortn ame���a solar � , ! • SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US SE3800A-US SE500�1-US SE6000A-US SEJ600A-US SE10000A-US SEIIGOOA-l15 OUTPUT ��.. ........... SolarEdge Single Phase Inverters � NominalACPowerOutpu[ 3000 3800 5000 6000 ]600 9980@208V 11400 VA .. ... . . .. ... .. . . 10000 @240V . ... .. .... ..... ..... 5400 @ 208V. ....... ......... 30800 @ 208V For North America Max.PCPowerOu[p t 3300 4150 6000 8350 12000 VA � 5450 @240V. ....... . . ..... 10950 @240V ..... . .._. . . ... . ... ... .... ... . ....... ._.... .. .. ...... AC Outpu[Vol[age M n:N -Max. J - - J - SE3000A-US/ SE3800A-US/SE5000A-US/SE6000A-US/ 183-206-2]9Vac J , J , J , ✓ _.............................. .... .._............ .. .._.. ..... ............_... . ......... ... ................ ... .............. .......__....... ._ . ... AC Outpu[Vol[age Min:Nom.-Max.' SE7600A-US/SE10000A-US/SE11400A-US zii-zao zeava� _ ACFrepuencyMin Nom:Max 593:60 605� thHlrountryseM g9 60 605) „__ Hz M x.Conhnuous O tPut C �ren[ . ... 12 5 . I�� .16 I II@ 240V I .....25 I. ....3� I 42 @ 240V I 4Z5 A .�_.�" --._�_� GF�I._ ,..... _. _. .. .... 1_ _ .._........ ........... . .A..._ . � ..... ..... .... ........ .. _.... ..........._ .. ........._ ........... . ... � Ubliry Mom[oring,Island ng � Pro[ection,Country Conhgurable Ves �, �- F`� eria""�,F� ThresholAs � q q � INPUT Y.��v ayply' A �STC�mme ded Max DC Power 3]50 9)50 6250 ]500 9500 12900 14250 W R y . . . .. .... . ...... ._. ....... ....... • ... . ...... � �'a Wa ' � Tansformerless Un&ountletl Yes o� ' .. ... ...._. �.,� �,.°:"„Wv: Max.InPut V It ge...... .. . ... . . .. . ... .. . . ....500 ... . . . Vdc . ... . . .... Nom DC I p t Vol[age 325 @ 208V/350 @ 240V Vdc _ £6' � � ... ... 16 5 @ 208V 33 @ 208V ... .. .... . �� , ��. Ma InP t C rren[ .. . .. . 9 5 I.... 13 .I 15 5@ 290V I ...18 23 I 30 5@ 200V I 34.5 Adc... ... .. . . ... M .Inp t5hor[C cu[C t 30 45 Adc , �� fte erse Polarity P t cnon Yes . . . . ... ... .. ... .. .. . . ........ ..... � ; Ground-FaultlsolanonDetechon 600kn5ensnvt ,,._,,,. . I • . ..... ............... Y....... ..... I . � .... .... . .. ... ... . .. .... . . .. .. .. . . _... . ... . MaximuminverterEfficiencY , ... ... 9JJ ... .....982 ...983._... ....96.3 .. ......98 .. ..... 98 98 Y ... . .. ..... . ........ 9Z5 @ 208V 9]@ 208V . CEC We gh[ed Effiaency 9l5 98 9]5 9].5 9Z5 % ...... . ...... ... ... .. . 98 C?240V.. ....... . ......... . 9)5 @ 240V ....... .. . .. ........... NighttimePowerConsumptlon <25 <4 9J , t , i,, . _. . ... . .. _ . '� � ADDITIONAL FEATURES �� ,,,e, t Supported Communicatlo I tertaces R5485,R5232,Ethemet,ZigBee(op4o al) . . � ... .......... . ... ..... . ......_... . ....... . . ....... .._........ ....... � ^r ^ Revenue G ade�ata ANSI C12.1 Opnonal i t� �STANDARDCOMPLIANCE . . _. . �I �, - -- '� �, Safe[y ULll41,UL1699B ULI998,CSP222 ....... ..... ......... .._.. .... ....... .._ ....... +� .. � — . . . . . ...._ ... ' �� ��� Gr d Co e[Uon Standards IEEE154] � .. . . ._ .. .... ... . ... .. . .... . .... ... . _ .__. � Em si ons FCC part15 dass 8 t INSTALLNTION SPEQFICATIONS ���. ACoutPv[co dutsize/AWGrande ... 3/4 mimmum/296NWG .... 3/4 minimum/83AWG .......... ... _. . . . .. . ... .._. . .... ...... ... � , , �Cinpu[w du[s e/Nofs[nngs/ � � � r 3/4"mimmu /12stings/396AWG 3/4mnmum/L2st gs/146AWG �,. NWG 2n4e . ._.... .. . .. .. . . ......_ . . . . �imensionswi[hAC/DCSafetV 30.Sx12.5x�/ 305x12.5x].5/ 30.Sx12.5x10.5/])Sx315x260 in/ � � � Swimh�H WxD� ]]Sx315x1)2 .]15x315�191 , mm . .. .._.. ... ... .... . . .... ........ .,, .e��..... .,. �.�-.�.._. ,�. .�' . Wei6h[wi[hAC/�CSafefVSwihh...... 512/232 54]/24].. . ....... 88:4/A01 . .... ... Ib/kg.. ^ _ .... .._ . ..... Cooling Na[uralConvechon F s� erreplareable) ........... .. ...... . . ._.......... ._ . .. ......... _... ........ .. ... ....... ...... � Noise <25 <50 dBA . .._._...... .................................___...._.-..............._... ....._....__.................................. .. ....... ....... .. .... The best choice for SolarE ge ena E S�/$Le1flS Min:Ma�.OperatlngTempera(ure 13[0+190/ Sro+60�CANversion"^-40m+60) 'F/'C � Integrated arc fault protectlon(Type 1)for NEC 2011690.11 compliance .aange _ , .. .......... . ......... . . . ...... ... .............. .. .... . ...... ...._.. ...... ...... Pm[ectlon Rahn6 ....NEMA 3R ......... ....... .........._.. .._ .. ._.. . . . ......... ... ....... . � Sup2�io�efficiency(98%� '�io,o�n.�regio�di:nn�¢:piea:e�o��a�isoi�,ide�.,,voea. ��� � - � — Small,li htwei h[andeas toinstallon rovidedbraeket ���im��.a�iasxm,m�ano��wne,.m�m..roa.e,aaeme��emoe�+��� �+�+e��'fisscam�oiasxm,w�.no�..n.,e�ei.n.ia,.rrns�c. g g Y P va�a.nu.amro�m:no�,,ere�m i �� '�� a � "qMg�¢�[urtenlsoui<emaybeusetl��M1elme�le�wlllllmltltslnputcurmn��o��evaluesslafetl. — Built-inmodule-levelmonitoring ���•cn„w�+�.,�.ue�m�io.m.a��,�ofi..�am���r�,im�..�rir..�.sev<ao>�usu.i. — Intemet mnnection through Ethemet or Wireless ` _ _ _ _ _,�, ,� , a_ y � _ __ , . . _.__ �„r_. . __ _ 4� � - Ou[doorandindoorinstallation . _� f W� � � — Fixed voltage inverter,DC/AC conversion only � - Pre-assembledAC/DCSafetySwi[chforfasterinstallation - � — Optional—revenuegradedata,ANSIC72.1 I sv�scE� � � USA-GERMANY-ITALV-FRANCE-1APAN-CHINA-AUSTRAIIA-THENETHERLANOS-ISRAEL wwwsolaredge.us � �