Loading...
4 BRENTWOOD AVENUE - BUILDING JACKET 4 Brentwood Ave. .y CARTER & TOWERS ENGINEERING CORP. �url.��, �aurzeeLcrizc�� Joseph 0 Carter Prolessrona)Engineer 6 FAIRVIEW AVENUE Registered Land Surveyor SWAMPSCOTT. MASS. 01907 Tel. 592-8386 LoT z 9 -. /OO.Ja I SNFO QN I ryaM W a n`G _ — rr 40.70 ... . co".5rRu Cr1Q" M Fxlsriv4 ' cyvRr"2� im vo.,.,usrrwh ; No. 4 =mak =t ' zS.oy I 'Ttn.t r LD I Vin O m DoT z93 95-65' SF OI v,Yni CO ~ Ca i 7/. 3Z _ To the SALLA 3Vr;,D/AlF SNSP 6crtj,7 PLOT PLAN OF LAND and -1-A'--1 6-s s-MIr;q SALEM, MASS 1 hereby certify that I have examined SCALE: 1 " = 20 the premises and all easements, APRIL /9, 1989 encroachmesis and buildings aro located on the grcmnd as shown, 1 further certify tl i•vildings shover, DIP /its of rr, ,voT conformal to t.„ laws of 5r91-Evr r tr'an constructed. I........... 1 , I further certi,y ,zt this structure ,u i s nI oT locatad in the / t —' established flood haz d ar "ya�_aaoS' )TESTS ......... .....A. .seph D. Carter I.S. #9387 SYS66 V'g9/gNCE DArEO /i/I/ 8 84SP239y CIVIL ENGINEERING PER OLATI SEWAGE DISPOSAL DESIGNS SURVEYING F-/2//6 1 -' .y f1Lit of 1ttlem, 14Eassachuslo103 8 33 Pourb of �Fpeal FILE-4 CITY CLFRK. ;A' ' L!.SS DECISION ON THE PETITION OF JAMES K . SMITH AND JEAN M. SMITH FOR A SPECI_AL_PERMIT_FOR 4 BRENTWOOD AVENUE (R-1) A hearing on this petition was held October 12 , 1988 with the following Board Members present : James Flemming , Chairman ; Messrs . Sencal , Strout , Labrecque and Nutting . Notice of the hearing was sent to abutters and others and notices of the hearing were properly published In The Salem Evening News In accordance with Massachusetts General Laws , Chapter 40A . The petitioners , represented by Attorney John G . Vallis , are seeking a Special Permit to allow construction of a deck , two-car garage and an enlargement of floor space for living area to be constructed on a nonconforming structure at 4 Brentwood Avenue, which is located In an R- I District . The provision of the Salem Zoning Ordinance which Is applicable to this request for a Special Permit is Section V B 10, which provides as follows : Notwithstanding anything to the contrary appearing In this Ordinance , the Board of Appeal may , In accordance with procedure and conditions set forth In Section Vlll F and IX D, grant Special Permits for alterations and reconstruction of nonconforming structures , and for changes, enlargement , extension or expansion of nonconforming lots, land , structures , and uses , provided , however , that such change , extension , enlargement or expansion sharil not be substantially more detrimental than the existing nonconforming use to the neighborhood . In more general terms , this Board Is , when reviewing Special Permit Requests , guinea oy the ruie tnat a Speciai Permit Request may be granted upon a finding by the Board that the grant of the Special Permit will promote the public health , safety , convenience and welfare of the City ' s Inhabitants . The Board of Appeal , after hearing the evidence , and after viewing the plans presented , makes the following findings of fact : I . No opposition to the Petition was presented at the hearing ; 2 . Councillor Leonard O' Leary spoke In support of the petition , indicating that the proposed construction would be an appropriate enhancement for single family use and further indicated strong neighborhood support of this petition ; DECISION ON THE PETITION OF JAMES & JEAN SMITH FOR A SPECIAL PERMIT FOR 4 BRENTWOOD AVE. , SALEM 2 3 . A Petition signed by twenty-one neighbors and abutters In favor of the proposed construction was submitted ; and , 4 . Several neighbors and abutters appeared and spoke In favor of the proposed construction . On the basis of the above findings of fact , and on the evidence presented at the hearing , the Board of Appeal concludes as follows : 1 . The proposed construction will promote the convenience and welfare of the City ' s Inhabitants and will be In harmony with the District . 2 . The relief requested can be granted without substantial detriment or without nullifying or substantially derogating from the Intent or purpose of the Ordinance . Therefore , the Zoning Board of Appeal voted unanimously , 5-0, to grant the Special Permit , allowing the construction of a deck , two-car garage and enlargement of living area to the existing nonconforming structure, subject to the following conditions : 1 . All the requirements of the Salem Fire Department , relative to fire and safety, be adhered to . 2 . All construction meet the requirements of the City and State Building Codes . 3 . The exterior appearance be constructed In harmony with the existing structure. 4 . All dimensions and setbacks to be constructed as per the plans submitted . 5 . A Certificate of Occupancy be obtained prior to occupancy . 6 . With the exception of kitchen facilities, all construction to be done as per the plans submitted . 7 . No kitchen facilities to be Installed within the new construction . 8 . The words " In law apartment" in the plan ' s heading be struck off and changed to now read "extension" . SPECIAL PERMIT GRANTED c�T JOHN NUTTING, Memb APPLAL FRO!A THIS DECISION. IF ANY. SHALL BE MADE PURSUANT TO SECTION 17 OF THE WIX 6 EN.E RAL LAGS. clinPTLR £C£. ALD SHALL BE FILED WITHIN 20 DAYS AFTER THE DATE OF FCI^!;, OF THIS DECISION IN THE OFFICE OF THE CITY CLERK. P IIPSSNi TD L:=.SS. GENERAL CHAPTER SOS, SECTION 11, THE VARIANCE CR CTris ?"IT J R;dd!EO HEnECl, `HALL N::I lA`.E EFT-17UNTILA COPY OF THE f.ECISiD^:. TiiF FIGF.TI)N GF THE CKY CLEP, T'r.AT 2, DAYS HAVE ELAPSED AND NO APPEAL HAS E`_E 11 OR THF.:, IF SLl:H AN APPEAL HAS BEEN FILE, THAT IT HPS BEEN D1£:.'ISSED OR Du;IEJ IS RE.�I?DEO L'. THE SOU?H ESSEX RECISTCY OF DEEDS AND INDEXED UNDER THE PLA:.:E OF Tri,. C OWN OF RECURD OR IS RECORDED AND NOTED ON THE O'ANEWS CERTIFICATE OF TITLE. BOARD OF APPEAL P -tLl- j $ qs 0- 3 l ?_q The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code, 780 CMR SALEM ..' Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only (Y1_ Building Permit Number. Date lied: Building Official(Print Name) Signature Date �— SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers i �v ie tnh.x,na L l a is this an accepted street?yes_ no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Ne a Zoning District Proposed Use Lo[Area(sq ft) Frontage(R) Z 1.5 Building Setbacks(ft) r n c) Front Yard Side Yards Rear Yard U7 r, G Required Provided Required Provided Required Prov' d rn O 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: - Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal sysW ❑ Check if yesC3 SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Record: James Smith Salem, Ma. 01970 Name(Print) City,State,ZIP 4 Brentwood Ave 978-745-9656 Jksjms@live.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work': srAei_a SU c�v� 41 Q42 S lm SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1. Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical ❑Standard City/Town Application Fee $ t Co " ❑Total Project Cose(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No. Check Amount: Cash Amount: 6.Total Project Cost: qO vjo-co ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 1� J (,gym c� S�Qryy—Lpe _� LiOcens N2 b, Expiratio Datep Name of CSL Flolder 2= f !/ _e- `A List CSL Type(see below) U No.and Street 1� Type Description �`/11U1 n U Unrestricted(Buildings u to 35,000 cu.tt. AN✓ t lL/l �-l' R Restricted1&2 Family Dwelling CitylCowq Stale,ZI M Masonry RC Roofing Covering WS Window and Siding _ SF Solid Fuel Burning Appliances -1 �p13p5 SO.PAV@,\i\yil 1GY I Insulation Telephone Email address D Demolition 5.2�s 'Regis `t Imter`e/d�Home Improvement Contractor(HIC) \,o%q 21 y `J� \ w`ar HIC Registration Number Expiration Date HIC Col RSgy,LM r„j-iIC,Registlant Name No.an¢-$�v[1lr�e)'1Jr'J u U�(.`� aAwo,"�` �� Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........❑ No...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize \ on t so y- to act on my behalf,in all matters re l to work authorized by this building permit application. 11/20/14 Print Owner's Name(E rot Si alure) Date SEC : OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Gvt � Sri_,,-�. � Print Owner's or Authorized Agent' a(Elec nic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass ov/dps/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" DDNYYYI A CERTIFICATE OF LIABILITY INSURANCE °o31/201<4 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER N TA CT MARSH USA INC. AME: 122517TH STREET,SUITE 1300 NCO N Ext, I ac No]: DENVER,CO 80202-5534 E-MAIL Attn:Denvercertrequest@mmsh.com,Fax:212.948.4301 ADDRESS: - INSURE S AFFORDING COVERAGE NAICd 462738-STND-GAWUE-14-15 INSURER A:Evanston Insurance Company 35378 INSURED Mvint Solar,Inc: INSURER a Zurich American Insurance Company 16535 Mvint Solar Developer LLC INSURER C:American Zurich Insurance Company 40142 3301 North Thanksgiving Way INSURER D: Suite 500 Lehi,UT 84043 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002368030-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EX" POLICY NUMBER MW MM/O LIMITS A GENERAL LIABILITY 14PKGWE00274 11/01/2014 11/01/2015 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea oxumence $ - 50,000 CLAIMS-MADE M OCCUR MED UP(Any one person) $ 5,000 X $5,000 Dec.BI&PD PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE S 2,000,000 GENL AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGO $ 2,000,000 POLICY X PRO- LOC S B AUTOMOBILE LIABILITY BAP509601500 1110112014 11/0112015 EOMaBBIIRM SINGLE-LIMIT 10000W Ix ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) S AUTOS LITOS X NON-O MED PROPERTY DAMAGE $ HIREDAUTOS AUTOS Par accident) A UMBRELLA LlAB X OCCUR 14EFXWE00088 1110112014 11/01/2015 EACH OCCURRENCE $ 5,000,000 X EXCESS LWB CLAIMSMADE AGGREGATE $ 5,000,000 DED RETENTIONS $ C WORKERS COMPENSATION WC509601300 11/01/2014 11101/2015 X I VVC STATU- OTH- ER AND EMPLOYERS'LIABILITY ITS ER B ANY PROPRIETO"ARTNERIFXECUMIVE YIN WC509601400 11/01/2014 11/01/2015 E.L.EACH ACCIDENT S 1,000,000 OFFICERIMEMBER EXCLUDED? F—N] N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 u yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Errors&Omissions& 14PKGWE00274 1110112014 1110112015 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (AUach ACORD 101,Additional Remarks Schedule,N more apace is raqulmill The Certificate Holder and others as defined in the written agreement are included as additional insured where required by written contract with respect(o General Liability.This insurance is primary and non. contributory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract Waiver of subrogation is applicable where required by written contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe r .Lr.!lav c7lr. Ili "6a 01988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations I Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/State/Zip: Lehi, UT 84043 Phone #:801-377-9111 Are you an employer?Check the appropriate box: Type of project(required): 1.0 I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time). have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance? 9. Building addition required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152, §1(4),and we have no Solar Installation employees. [No workers' 13.R Other comp. insurance required.] 'Any applicant that checks box NI most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tcontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is flee policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic. #:WC 509601300 Expiration Date: 11/1/2015 Job Site Address: �A �� a-� City/State/Zip: Qa W wl Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct Signature: %��L Date: Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Office of Consumer Affairs find Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. soA 1 C, 2OM-05/11 Address Renewal 0 Employment ❑ Lost Card fit Massachusetts -Department of Public Safety Board of Building Regulations and Standards Construction Supe 5 License: CS-045254 J` y JAMES R SHERMAN Hollow D50 S AU A GUS M 01406 � Expiration 08/28/2016 Commissioner V V o t solar 3301 North Thanksgiving Way,Suite 500 Structural Group Lehi,UT84043 P: (801) 234-7050 Scott E. Wyssling, PE Head of Structural Engineering scott.wysslingOvivintsolar.com November 20, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Smith Residence 4 Brentwood Avenue, Salem MA S-4059721 6.63 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of two sections. Roof Section 1 (the main house): has 2 x 6 dimensional lumber at 16" on center with 1 x 8 collar ties every 32". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. Roof Section 2 (the back porch): has assumed 2 x 6 dimensional lumber at 16"on center. This space is finished. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 12 and 32 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint solar Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF=Live Load (ground snow load) • 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, o�� tHOF oy� _P� Y y Scott E. Wysst PE ° 50 MA License N . 50 9�F FG1s-r FSSIOWA- vivint. solar r----------------------------- 4 Brentwood Ave, Salem MA 01970 Hamm LJUNCTION BOX ATTACHED TO ARRAY USING ECO HARDWARE TO i KEEP JUNCTION BOX OFF ROOF I E m r m-j L<mo � U C_ U ( ( ''E^ VJ j PV SYSTEM SIZE: 6.63 kW DC L- I ° • I I v Ip O N Q W Oi I 6 m $ c n m � U (26)YhQ1i Enemy YL255P-29b MODULES WITH Enohase M215-60-2LL-S2x-ZC MICRO-INVERTER ( MOUNTED ON THE BACK OF EACH MODULE z m w w NE PV INTERCONNECTION POINT, I LOCKABLE DISCONNECT SWITCH, 115'OF 1"PVC CONDUIT ANSI METER LOCATION, Z Z FROM JUNCTION BOX TO ELEC PANEL 8 UTILITY METER LOCATION I SHEET NAME: L------------------- - ------------� , g Ua SHEET NUMBER PV SYSTEM SITE PLAN SCALE: 3/32"= V-0" > a AA� MMOO 880 OO o & 0 N3vi N U^ R0 i0i N 0 N n 00 Op D m� m� x O0 'er, c� rc_ N~ x N D r CI) m - w Cn m om o X O o i 0 O ti m y T x r m D Z c i D i INSTALLER:VIVINT SOLAR ;m Km N ALLESE:MAHECi]08484044129 @�0�0��. solar Smith Residence `, ou M ROOF m m v 4 Brentwood Ave P1/ 2•Q p~ ~ Salem,MA 01970 PLAN DRAWNBY:RBR JAR4059721 I Last Modified 11/17/2014 UTILITY ACCOUNT NUMBER:50665-32002 CLAMP MOUNTING SEALING PV3.0 DETAIL WASHER c m a� LOWER m SUPPORT 'N$om oQF E� i< z PV MODULES,MODULES,TYP. MOUNT "`" "`' allo OF COMP SHINGLE ROOF, FLASHING < PARALLEL TO ROOF PLANE / 2 1/2" MIN 5115"0 x 4 1/2" L MINIMUM STAINLESS (TS PV ARRAY TYP. ELEVATION STEEL LAG SCREW NOT TO SCALE TORQUE=1332 R-Ibs Q CLAMP ATTACHMENT tJ) NOT TO SCALE •e ? CLAMP+ 8 ATTACHMENT CANTELEVER L/4 OR LESS oC COUPLING J L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. 8 COUPLING rc e PERMITTED g m n a CLAMP+ CLAMP CLAMP w � ' a ATTACHMENT SPACING = m i COUPLING PHOTOVOLTAIC MODULE ; z w .. m m N w m liz Z Q MID SHEET t7NAME: L=PORTRAIT N CLAMP SPACING Z Q 7 � O ECO 2 p COMPA L=LANDSCAPE MODULEIBLE PV SYSTEM MOUNTING DETAIL SHEET CLAMP SPACING rvumeEa: MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE a Inverter Ratings(Guide Section 4) Q Conduit and Conductor Schedule Inmder MakarModel Enphae M21560.2LL52z20 Ts; Oesstlption 'Mn Gaups pot COMuuoo cusea Type Crodsisue MODULE DETAIL Max DC Vat Rating 4s Volfs Enpaaw vrpyde•asF-TNWN2 12PWG Q Cv4 WA-Fin Pir Max POwar its 4n•6 215 Watts NOrrinal AC VOXage 24n VDUs 9are rM9°GwMIEGfIGEL) fiPWG 1 NlA-fret Nr r /r\ O Yingli Energy YL255P-29b Max Ac cumem o9 Amps z rHwrvs mAwG p rvc �We.7 YU/ SOLAR MODULE Max UUFu Hating 20 Amos 2 Imeat Gmuae aase 1 PVC 7-1. Max Number of PanleCiui1 1] s TM1yP,2 BAWL s NC FV ce se NOTES FOR INVERTER CIRCUITS(Guide Betties 0 and 91, a TNWe3-GmmF aass 1 N'C p -0 cir 1.)IF UTILITY REQUIRES AVISIBLE-BREAK SWITCH,ODES THIS PV Module Ratings Q STC(Guide Section 5) e�e�� Enphase M21"O-2LLS2x-ZC SWITCH MEET THE REQUIREMENTS? W E 2 Moral MaksoModel Yin Energy YL255P-29b N v MICRO-INVERTERMODULE ATTACHED YES NO XNA Max Pesor-Pent Current(imp) 9 8.32 Amps LL Ez EACH MODULE,ATTACHED 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Point ValUge(VmD) 30.6 Valfs mWD wo WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? aL-+p O Open,, iil Voltage 30.7 Vafta YES NO %NA 6M1odLimuil Current(Isc) B.BB AmpsQ B SIZE N CURRENT TON NEC6SOURCE.53(DCSIGOR CONDUCTORS Max Series Fuse(OCPD)Posse 15 Amps BASED A MAXMACONNE T.ON NEC 69D5381GN OR OCPD Nominal Maximum Parer at STC(Pmex) 255 Wane MICROINVERTER CONNECTION _ RATING INVERTER Maximum system Voltage 1000(IECyNq 1) j TO ENGAGE TRUNK CABLE 0.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature Coefficient A.32 Yd'C ^ TO INVERTER OCPD AMPERE RATING(San Guide Section 9). V 5.)TOTALOF 2 INVERTER OCPD(a).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Aooendlx Dl: W CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme NEC 590.64(B)(2)(a)? XYES NO dry bulb temperature for ASHRAE location most similar to installation locaban: -19-C #6 BARE CU GROUND (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb as temperature for ASHRAE location most similar to installation location: 39-C O Sign for inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47-C in the Solar PV System AC Point of Connection United States(Palm Springs,CA is 44 A'C).For less than 9 cuoentcxn m ying nduclors in rcofmounted sunlit conduit at least CS'above mod and using the outdoor design AC Output Current 23.400000 Amps temperature of 47-C or less(all of United States). Nominal AC Voltage 240 VDUs a.)12 AWG,90-C Conductors are generally acceptable for modules with Ise of 7,68 Amps \ram or Was when protectetl by a 12-Amp or smaller fuse. 0 LTIPLE THIS PANEL FED BAND SOILAR)SOURCES b j 10 AWG,90-C conductom are generally acceptable for modules With 1.of 9.6 Amps (UTILITY AND BOLAR) or ous when protectedb a 15-Amp or smeller fuse. NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR On a PV CIRCUIT 1: 17 MODULES/PARALLEL ENVOY BOX <. m us rc ^ a 0 m o a 17 • • • O O f ^ Q TPANEL m1 E > ; EmE1.0MURRAY POINT OF DELIVERY >CCOMBINER AND INTERCONNECTION w w wlo;P 125A/240V SIEMENS d+ 2LWO04NR BOA/240VO\ EQUIVALENT UNFUSED NEMA3 3 3 fQ\0' t, 15 SREC/ANSI LNF222R OR SHEET PV CIRCUIT 2: 9 MODULES/PARALLEL �.�m/F METER EQUIVALENT NAME: OA\V �• EXISTING \O,p )3MM 240V/200A W 1 \ 20A LOAD-CENTER z (.7 E 1.0 S • • • S f \\ SHEET NUMBER: ILBANK •y JUNCTION BOX 2 \\\\ 3 1^ VISIBLE/LOCKABLE ODA OR 3 KNIFE'A/C BLE 3 O WITH IRREVERSIBLE \ EQUIVALENT DISCONNECT NEC 2014 Compliant GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 LLI Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: James Smith Project Address: 4 Brentwood Ave,Salem MA A.System Description: The array consists of a 6.63 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(26) 255-watt modules and (26)215-watt micro-inverters,mounted on the back of each PV module.The array includes (2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar. B. Site Design Temperature: (From Boston Logan INVL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: EcoX Comp. Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrlum Solar b. Product Name: Ecorail c.Total Weight of PV Modules and mounting hardware: 1094.8 Ibs d.Total number of attachment points: 75 e.Weight per attachment point: 14.59 Ibs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 457.18 square feet h.Array pounds per square foot: 2.39 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (21)modules,(55)attachments 16.07 pounds -Roof section 2: (5)modules,(20)attachments 10.52 pounds per square foot vivint. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Yingli Energy YL255P-29b 26 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp -rated voltage at maximum power - 30 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Ise-rate short circuit current - 9.01 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21A, S22 26 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C. System Configuration Number of PV circuits 2 PV circuit 1 - 17 modules/inverters (20) amp breaker PV circuit 2 - 9 modules/inverters (15) amp breaker 2011 NEC Article 705.60(8) vivint. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 15.3 amps Continuous current adjustment factor 125% 2011 NEC Amide 705.60(13) PV circuit continuous current rating 19.125 amps 2. Overcurrent protection device rating PV circuit continuous current rating 19.125 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12 °F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC A,vde 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Arude 705.60(B) Adjusted PV circuit continuous current 26.9 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Arucle 705.60(B) Final Adjusted PV circuit continuous current 21.5 amps Total derated ampacity for PV circuit 21.5 amps Conductors(tag2 on 1-line)must be rated for a minimum of 21.5 amps THWN-2(90°C) #10AWG conductor is rated for 40 amps (Use#10AWG or larger) 2011 NEC Article 705.60(B) 4.Voltage drop(keep below 3%total) 2 parts. 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1.Mirco-mvertcr voltage drop: 0.24% The largest number of micro-inverters in a row in the entire array is 7 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.24%. 2.AC conductor voltage drop: =1 x R x D (+240 x 100 to convert to percent) = (Nominal current of largest circuit) x(Resistance of#1 OAWG copper)x (Total wire run) = (Circuit 1 nominal current is 15.3 amps)x (0.00126Q)x(230� _(240 volts)x(100) 1.84% Total system voltage drop: 2.08% vivint. solar EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 16156 Street Address Line 1: 4 Brentwood Ave Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity: 26 Array Size (DC wafts): 6630.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 40.8lbs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load - Upward: 820 Ibf Lag Bolt Design Load - Lateral: 288 Ibf EcoX Design Load - Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment— Upward: 3655 in-lb Module Design Moment— Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar [Mane Calculations (ASCE 7-05): 1 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 21.0 deg Truss Spacing: 17.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.9 0.9 0.9 Roof Snow Load 30.2 30.2 30.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 30.2 30.2 30.2 psf Downslope: Load Combination 3 10.9 10.9 10.9 psf Down: Load Combination 3 28.5 28.5 28.5 psf Down: Load Combination 5 18.2 18.2 18.2 psf Down: Load Combination6a 33.9 33.9 33.9 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 33.9 33.9 33.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 53.6 53.6 53.1 in Max Spacing Between Attachments With Rafterlrruss Spacing of 17.0 in 51.0 51.0 51.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.9 17.9 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 32.2 32.2 32.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 17.0 17.0 17.0 in Max Cantilever from Attachment to Perimeter of PV Array 10.7 10.7 10.7 in EcolibriurnSolar Layout Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with ® Bonding Jumper maximum allowable overhang. EcolibriumSolar Plane Calculations (ASCE 7-05): 2 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 12.0 deg Truss Spacing: 17.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 35.6 35.6 35.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 - Design Wind Pressure Uplift -16.0 -26.4 1 -39.6 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 35.6 35.6 35.6 psf Downslope: Load Combination 3 7.7 7.7 7.7 psf Down: Load Combination 3 36.3 36.3 36.3 psf Down: Load Combination 5 18.3 18.3 18.3 psf Down: Load Combination 6a 39.8 39.8 39.8 psf Up: Load Combination 7 -14.6 -25.0 -38.2 psf Down Max 39.8 39.8 39.8 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 45.7 45.7 45.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 34.0 34.0 34.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.2 15.2 15.2 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 27.4 27.4 27.4 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 17.0 17.0 17.0 in Max Cantilever from Attachment to Perimeter of PV Array 9.1 9.1 9.1 in EcolibriumSolar Layout 0 Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with ® Bonding Jumper maximum allowable overhang. EcolibriumSolar Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1061 Ibs Weight of Mounting System: 150 Ibs Total System Weight: 1211 Ibs Total Array Area: 458 ft2 Distributed Weight: 2.65 psf Number of Attachments: 75 Weight per Attachment Point: 16 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 75 ECO-001_102 EcoX Coupling Assembly 37 ECO-001_105B EcoX Landscape Skirt Kit 5 ECO-001_105A EcoX Portrait Skirt Kit 4 ECO-001_103 p EcoX Composition Attachment Kit 75 ECO-001_109 EcoX Electrical Assembly 2 ECO-001_106 EcoX Bonding Jumper Assembly 5 ECO-001_104 EcoX Inverter Bracket Assembly 26 ECO-001_338 EcoX Connector Bracket 26 6-1K ZR 2<� The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF ` / Massachusetts State Building Code, 780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official se Only n(1 Building Permit Number: Date A plied: Building Official(Print Name) Signature Date! / \'�J SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 1.1 a Is this an accepted street?yes_ no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq 11) Frontage(tt) 1.5 Building Setbacks(ft) r,. Front Yard Side Yards Rear Yard Required Provided Required Provided Required Pro d n IV 1.6 Water Supply:(M.G.L c.40,§54) L7 Flood Zone Information: 1.8 Sewage Disposal System: � Zone: _ Outside Flood Zone? M Public❑ Private❑ Check iFloo❑ Municipal❑ On site disposal sys> ❑ l7 SECTION 2: PROPERTY OWNERSHIP' t 2.1 Owner of Record: James Smith Salem, Ma. 01970 ul t Name(Print) City,State,ZIP 4 Brentwood Ave 978-745-9656 Jksjms@live.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work': } y'� S IM' SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I. Building $ `7 I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ El Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (I VAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ •-� i 6.Total Project Cos[: $ Check No._Check Amount: Cash Amount:_ 0 Paid in Full 171 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) (, 0��25y S Le Jaffl_,s License Number Expiration Date Name of CSL Holder i E . _ LL_ m a� _p ,t List CSL Type(see below) U No.and Street 1 1� CJ�` Type Description �� � , p U Unrestricted(Buildingsu to 35,000 cu.it.) City/fowq State,ZI7� "1 R Restricted I&2 FamilyDwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 7hldOSaU1PJ M�SVYJ �iy\\1ii\�lY [ bnsutation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) \t\y \nt" scxa.r \�hllu HIC Registration Number Expiration Date HIC Co v Name or HIC,Registrant Name rG��b\ N •3(�CJ W No.anQ tmet bu U,C y ,L/ry�. Email address Ci /Town,State,ZIP t Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuanee,of the building permit. Signed Affidavit Attached? Yes ........,:❑ No...........0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize__..V\V\Y)t ��1r to act on my behalf,in all matters rel ' to work authorized by this building permit application. 11/20/14 Print Owner's Name(E fro c Si amre) Date SEC :OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained i application is true and accurate to the best of my knowledge and understanding. qI Print Owner's or Authorized Agent' me(Ele n� is Signature) Date1 NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.zoo Information on the Construction Supervisor License can be found at www.mass.eov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost' 1-4 The Commonwealth of Massachusetts Department of IndustriadAccidents — ts Office of Investigations Fa Y I Congress Street,Suite 100 Bostota avavw mass.govIdia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applieant,information Please Print L.enibiv Name (Business/Organization/Individual): Vivin] Solar Developer, LLC Address: 3301 North Thanksgiving Way, Suite 500 City/Starc 7_ip: Lehi, UT 84043 Phone #:801-377-9111 Are you an employer? Check-the appropriatebox: Type®i�voJect(n p yaired): 1.13 I am a employer with` �� 4: Q I am a general contractor and I ` employees (folk and/or part-time). » have hired the sub-contractors 6 ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. Remodeling shipand have no-employees These sub-contractors have 8. ❑ Demolition working for mein any capacity: employees and have workers' 9. Building addition [No workers' comp. insurance comp. insurance. required.] --- - 5. We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no Solar installation employees. [No workers' 13.0 Other comp. insurance requt ed.] *Any applicant that checks box Nl most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number_ I am an employer that is providing workers'compensation insurance for any employees. Below is the policy and job site Information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins- Lic. #:WC 509601300 Expiration Date: 11/1/2015 i Job Site Address:_T 1)(Yj tl4tN0 City/State/Zip: 1 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations ofthe DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the injorana3ion provide abov is dr and correct Simature: Date �/, Phone#: 801-2296459 =(cireleone): use only. Do not write in this area,to be completed by city or town offaeial. n: Peramit/Lieemse # hority(circle one):health 2. Building Department 3. City/'Town Clerk 4. Electrical Inspector 5.Plumbing Inspector rson: Phone#: ACORU® DATE(xwenm M CERTIFICATE OF LIABILITY INSURANCE 10/31/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER IMPORTANT: H the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. N SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this Certificate does not confer rights to the certificate holder in lieu of such endorsements). PRODUCER NAME: MARSH USA INC. NAMPHOE: FA% 122517TH STREET,SUITE 1300No. pm xo DENVER,GO 80202-5534 Mc, Am:Denver.usmequele@mersh.mm,Fax:212.948.4381 INSURERS)AFFORDING COVERAGE MIC a 462738-STNOGAWUE-14-15 INSURER A:Evanston Insurance Company 35378 msu"YNint we,.Is, INSURER e:Z sura udch American Insurance Company 16535 Vivint Solar Developer LLC INSURER C:Artedam Zurich Insurance Company 40142 3301 North Thanksgiving Way Suite 500 INSURER o: Lehi,UT 84043 INSURER E: _ INSURER F: COVERAGES CERTIFICATE NUMBER: SFA-002368030-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POUCY EFF POLICY EXP LTR POLICY NUMSER LIMITS A cENENAL LJAaA1N 14PKGWE00274 1110112014 1V6112015 EACH OCCURRENCE $ 1,000.000 X COMMERCIAL GENERAL UASIUTV ISES'IU KtF10E,t nw) § 5D,000 PREMCLAIMS-MADEff]OCCUR MEDEXP(An . w.r) S 5,000 FX S5,000 Dad.818 PD PERSONAL AADV INJURY S 1,000,000 GENERAL AGGREGATE $ 2,000.000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMPIOP AGG $ 2,000,000 POLICY F X I 3TPT LOC $ 8 FXANY 08 UAswTY SAP5096015M lV0112014 1IM112015 MBINED I LE LIMIT flEa aaden0 1,000,000 AUTO BODILY INJURY(Par peracm S O SCHEDULED OS BODILY INJURY(Per accident) S EDAUTOS X NON-OMED PROPERTYDAMA E S AUTOS Peranxtlem S A UMENELLA Laus X OCCUR 14EFXWE000BB lV01/201a 11101/2015 EACH OCCURRENCE $ 5,000,000 X EXCESS UAS CLAIMS-MAOE AGGREGATE S 5,000,000 OEO RETENTIONS $ C WORKERS COMPENSATION WC509601300 1V0172014 1110 15 4VC STATl4 DTH- ANDEkrPIDYERa IMUIWTY B ANY PROPRIETORIPARTNERIEXECUTIVE YIN WC509601400 1110112014 1110112015 1,000,000 OFFICERIMEMBER EXCLUDED? Q NIA E.L.EACH gCGDEW S (Mandatery In Nib E.L.DISEASE EAEMPLOY 1,000,000 IfyB8'aurae under 1,000,000 OPR(�IPI'ION OFOPERATIONS Mow EL.DISEASE.POLICY UNIT $ A EImra80missicnSB 14PKGWE00274 11IOlQO14 11/0112015 UMIT 1,000,OW Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONSI LOCATIONS I VEHICLES (ALbdr ACOIWIM,AWRIA IRamrrkB ScM ule.Ilmomaaecalamqurmdl The Certificate Holder and others as defined in Ore wdtlen agreement am imiuded as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- contributory over any e)dsflng insurance and limited D liability arising out of the opere5ons of he named insured and where required by written contract Waiver of submgaten is apWcable when,requimd by written contract with respect to General Uabifity and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISION& AUTHOR20 REPRESENTATIVE of Marts USA Inc. Kathleen M.Paraloe ¢ a7i[. iawzw 0 198 8-201 0 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD I Office of Consumer Affairs nd Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card • VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. SCA 1 o 20M-05n1 ❑ Address Renewal ❑ Employment ❑ Lost Card fit Massachusetts -Department of Public Safety f Board of Building Regulations and Standards Construction Supenisor License: CS-045254 JAMES R SHER - Ac 6 Fox Hollow Drttie" SAUGUS MA 01%% g�5 �j Expiration Commissioner • 08/28/2016 eowon1 solar 3301 North ThanksgivingWav,Suite 500 Structural Group Lehi, of 84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scoft.wyssling@vivintsolar.com November 20, 2014 Revised April 20, 2015 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Smith Residence 4 Brentwood Avenue, Salem MA S-4059721 10.965 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of two sections. Roof Sections 1 and 3: (the main house): has 2 x 6 dimensional lumber at 16" on center with 1 x 8 collar ties every 32". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. Roof Section 2(the back porch): has assumed 2 x 6 dimensional lumber at 16"on center. This space is finished. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCEISEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 12 and 21 and 22 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per(ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. dodont. solar Page 2 of 2 B. Loading Criteria • 10 PSF=Dead Load roofing/framing . 40 PSF=Live Load (ground snow load) • 5 PSF=Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 %" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, o� SNOFyG c 4 CND a' Scott E.VVysslig, PE ° so MA License N . 50 9oF Fc,STEP� FSSIONA- dueunt. solar J` it 4931 North 300 West,Part UT 94604 Employer Identification No.: 80-0756438 V,v'n�• A O I Phone:(877)404-4129 Fax:(801)765-5758 Massachusetts HIICC License No.: 170848 E-Mail: suppon@vivintsolarcom o 59 I a I s www,vivintwiar.com AR NO.: RESIDENTIAL POWER PURCHASE AGREEMENT This RESIDENTIAL POWER PURCHASE AGREEMENT(this"Agreement')is entered into by and between VIVINT SOLAR DEVELOPER,LLC,a Delaware limited liability company("We","Us","Our")and the undersigned Customw(s)("You",by, as of the Transaction Date set forth below. Full Name(First MI,twp /� ♦- Full Name(Fim.Mi.s-r) Customer(s): P.°yerao.ver: D r, ❑No Q aaam o,r n❑Y. o.vuUa C' Telephone No.: '� x,s E-Mail: GS ,r cVe,Co PJA Property Street Address: V2 Address: City,County,State,Zip: 1.SERVICES A. DESIGN AND INSTALLATION. We will design,install,service and maintain a solar photovoltaic system on Your Property,which will include all solar panels,inverters,meters,and other components(collectively,the"System"),as further described in Customer Packet and the Work Order that We will provide to You hereafter. All material portions of the System will be installled by Our employed technicians and electricians,and not subcontractors. With Your cooperation, We will(i) desigo, insmll and connect the System in material compliance with all applicable laws; (ii)complete all required inspections;and(iii)obmin all required certifications and permits. In order to design s System that meets Your needs,You agree at We may obtain Your electrical usage h[story from Your electric utility(the"Utility and You shall provide s with copies of Your Utility bills as We may reasonably request. Other than the adivat[on fee described in Section LB We.will�esign=andinstall the.Sys[em at n0 ost_[o You.l B. ACTIVATION. You agree[p pay Us a one-time activation fee N the amount of$ We will interconnect the System with the Utility,and cause the System to genem[e energyy measured in kilowatt hours ( kWh"))(the "Erier�y nstallation of the System generally takes one day and is anticipated to begin end be subamnually complete between two(2)and six(6)weeks hereafter. C. OWNERSHIP OF SYSTEM. We shollown the System as Our sale personalproperty.�You`ill have no property interest in_the System. D. OPERATIONS AND MAINTENANCE. We will operaie and mninlain the System(i)at Our sole costm[d.expense;(ii).in good condition]and(iii)in material compliance with all applicable laws and permits and the Unhty s requrtements. __ _ _Y_, 2 E. INSURANCE. We cam'commermal general liabilityinshnnce workers compensation insurance;'and property insurance on the System For more information concerning Our insurance,and io obtain a copy of Our cenlfica[e ofinsmance,please visit Www.vrvmtsolacconilinsurance. 2.TERM,PRICE,PAYMENTS,AND FINANf, DISCLOSURES A...ENERGY-PRICE. For all Energy produced.by the System,You shall.pa�_Us S0. per kWh(the"Energy Price'),plus applicable taxes. The Energy-Price shall increase each year tiy two and nine-Tenths 9Vercent(2.9 Y). A g moo�F t`�esmm1te of the System output,measured m kilowatt hours, will be provided to You in the Customer Packet. THIS AGREEMEINTiSFOR THE SALE OF ENERGY BY US TO YOU AND NOT FOR THE SALE OF A SOLAR ENERGY DEVICE. B. TERM. This Agreement shall be effective as of the Transaction Date and continue until the n_tieth(20")anniversary of the In-Service Date(the "Term'). The"In-Service Doe"shall be the firs[day after all of the following have been achieved (i)the System has been installed and is capable of generating Energy,(ii)all permits necessary to operate the System have been obtained,(iii)the System has been interconnected with the Utility,antl(iv)all inspections and certificates required under applicable law or by the Utility have been completed or received. , C._PAYMENTS. 'Beginning wfth the first month following the In-Service"Date and Stlroughout the Term,We will send You an invoice rcilecting the charges for Energy pr uced by-the System-in the previous month-`You shall make monthly payments to Us by amomalic payment deduction from Your designated checWng account or credit card.-It is Vour responsibility[o ensure that there are adequate funds or adequate credit limit. There is an. o financinngg charge associated with this Agreement. For all paymants more then ten(10)days past due,We may impose a late charge equal to Twenty-Five Dollars(S25) and interest at an annual rate often percent(10°/),plus appliable coxes. If You conhnue to fail to make any payment x�thin ten(10)days after We give You written nonce,then We may exercise ell remedies evadable to_Us pursuant to Section 13/bl. HI y O amen[on a year to-year basis'(ii)enrer inm new Agrcemeni writs a D. RENEWAL. At[he end of the,Term,You ma elect to i.conhnue with this 7 Us and cancel this_A cemenq(in)purchase the Svstem at the end of Ihe_Term and cancel This Agreement(the Purchase Option');or cancel this A cement and have[ e System removed at no cos[m You iYou will need to notify Us in writing concerning Your election sixty(h days prior to the end the prior of�he Terms'If You elect the Purchase Option, the-"Purchase Option Price"will be the then-current fair market value of e System based on n i independent appraiser's valuation of similarly sized photovoltaic systems in Your geographic region. The appreiser's valuation will be provided to You n writing and will be binding. If We receive Your payment of the Purchase Option Price costs of the appreisal,applicable taxes,end all other amounts then owing and unpaid hereunder,We well transfer ownership of the System to Vou at the end of the Term on tin"As'fs,Where Is"basis. If You elect to have the System removed,We wilt remove the Systam from Vour Progeny within ninety(90))dayyss after the end of the Term. IF YOU DO NOT NOTIFY US OF YOUR ELECTION TO CANCEL BY SENDING A WRITTEN NOTICE TO US, THEN THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS UNTIL YOU NOTIFY US IN WRITING OF YOUR ELECTION TO CANCEL AT LEAST SIXTY(60) DAYS PRIOR TO THE END OF THE RENEWAL TERM. E. CREDIT CHECK. In connection with the execution of this Agreement and at any time during the Term,You hereby authorize Us to(i)obtain Your credit rating and report from credit reporting agencies,In)to report Your payment performance under this Agreement to credit reporting agencies;and (iii)disclose this and other information to(Tit affiliates and actual or prospective lenders,financing parties,investors,insurers,and acquirers. WE MAY HAVE'TRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE(SECTION 29) BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3.LIMITED WARRANTY A. LIMITED INSTALLATION WARRANTY. We provide_a workmanship waranyry that the System shall be free from material defects in desiggnn and workmanship under normal operating conditions for the Term. We.further war inl that id rooftop_penetrations We install shall be watertight as of the date oft ,workmanship do not provide any warranty to You with respect to any component of the Syystem. Any manufacturer's warranty is in addition to,not in lieu of, this limited installation warranty. This warranty does not cover problems resulnnQ'rom exposure to barmful materials and chemicals, fire, Flood, earthquake,or other acts of god,vandalism,alteration of system by anyone not authorized by Us,or any other cause beyond Our con"]. —1 B. MANUFACTURERS'WARRANTIES. The Syysstent's solar modules carry a minimum manufacturer's warranty of twenty(20 years' as, follows: of)during the first ten(10)ppears ofuse,the modules'elecnicat output will not degrade by more than ten percent(10'.)from the on rated Putpset;and (b)during the first twenty(20)years of use,the modules'electrical output will not degrade by more than twenty percent(20%)from the originally rated Outpset The Systetn's inverters carry a minimum manufacturer's warranty of ten(10)years against defects or component breakdowns. During the Term,We will enforce these warranties to the fullest extent possible. C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3, WE MAKE NO OTHER WARRANTY TO YOU OR ANY OTHER PERSON, WHETHER EXPRESS, IMPLIED OR STATUTORY, AS TO THE MERCHANTABILITY OR FITNESS FOR ANY PURPOSE OF THE EQUIPMENT, INSTALLATION, DESIGN, OPERATION, OR MAINTENANCE OF THE TION SYSTEM, THE PRODUC OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HEREUNDER, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANY BREACH OF ANY WARRANTY IS LIMITED TO REPAIRING THE SYSTEM OR YOUR PROPERTY TO THE EXTENT REpUIRED UNDER THIS AGREEMENT. YOU ACKNOWLEDGE THAT WE ARE RELYING ON THIS SECTION 3.C. AS A CONDITION AND MATERIAL INDUCEMENT TO ENTER INTO THIS AGREEMENT. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. 4.REMOVAL OF THE SYSTEM You shall not make any Alterations(as defined in Section 9(c��to the System. You want to make repairs or improvements to Your Property that require1 the temporary removal of the System or[hat could mterc with its performance or operation You must give V s at least thirty(30)days'prior written notice (a"Customer-Requested Shutdown"). You agree that any repair or Improvement to Your Property shall not materially alter Your roof where the System is installed. As compensation for Our removal,storage,and reinstallation of the System,You agree to pay to Us a fee equal to Four Hundred and Ninety-Nine 'Dollars(S499)before We remove the System. You shall be required to pay the Shutdown Payment(u defined m Section 15 If the System is not reinstalled within thirty(30)days of removal. In the event of an emergency affecting the System, You shall contact Us[mine late y. If We are unable to timely respond,You may(at Your own expense)contract with a licensed and qualified solar installer to remove the System as necessary to make repairs required by the emergency. You shall be responsible for any damage to the System that results from actions taken by Your contractor. 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quickly and amicably by calling Our customer service department at (877) 404-4129. If Our customer service department is unable to resolve Your concern,You and We agree to resolve any Dispute as defined below)through binding arbitration or small claims court instead of courts of general jurisdiction. BY SIGNING BELOW,YOU(ACKNOWLEDGE AND AGREE THAT(I)YOU ARE HEREBY WAIVING THE RIGHT TO A TRIAL BY JURY;AND(II)YOU MAY BRING CLAIMS AGAINST US ONLY N YOUR INDIVIDUAL CAPACITY,AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESENTATIVE PROCEEDING. You and We agree to arbitrate all disputes, claims and controversies arising out of or relating to a.m,;am eznu vma,o,"n,..mr.,.n.r na agsn x�a,.�o. a+n.uuni.xm rrn n_,. OF OUR AFFILIATES, DIRECTORS, EMPLOYEES. AGENTS, muJillyd hy.nn insmvnein in waling siyncJ br both Yoaundlls OR CONTRACTORS FOR ANY' SPECIAL.- EXEMPLARY 21. ENTI E AGREEMENT - Ths Ae u ih AlJtionl f.ms and INDIRECT. INCIDENTAL, CONSEQUENTIAL OR PUNITIVE Condition,, of Uut,m<, P LI iluo w kOI ;rod a > ofl a A,K, ,Ctv, ryumbdl ehh anslinu<•thrcntire vgarem rht cen\'ru and Us t DAN1ACiES(\NHEI'H@R OR NOT THEE CLAIM THEREFORE IS and alp d 111 pno sal and ,,it.,ncgoam,are,comma btu s.li v. Tansand BASED ON CONTRACT,TORT, DUTY IMPOSED BY LAW OR E2_BIYDINI:EFFECT 11 is.4eneinenie.bnll b bonging u rn and h,ure to the a OTHERR ISE),IN CONNECTION WITH.ARISING OUT OF.OR benefit of You and Lb and Om and Your respectbe heirs. ggal rc T'cntadvere. IN ANY WAY RELATED TO THE TRANSACTIONS sucttssors,and pannittetl usslcns. Fxee,l as mherwiso expressly provided in Iris CONTEMPLATED BY THIS AGREEMENT OR ANY ACT OR Ptsrecment ar by npemrm,l oT Iona,nefl�,<r Ihin ngicemmn nor en of tho righlz OMISSION OR EVENT OCCURRING IN CONNECTION nncrcsls,or ohlipations b<muodrr nmy be mslgncd b..Ynu wimem(ha pnorwnucn THEREWITH. YOU HEREBY WAIVE.,RELEASE,AND AGREE CO"soon. Mvese: nnrem by vouwnhom Otaplior avnlmn consent.sboll be a"id. E3.GOVERNIN ' LAW. ❑,is A retmenL and m inswmem or ag'si ul NOT TO SUE UPON ANY SUCH CLAIM FOR ANY SUCH nyni dharcnndec sn:dlF<yov<mdtgy.and conaw<d u'vdrr.,he ini an al la"v otIh, DAMAGES, WHETHER OR NOT ACCRUED .AND WHETHER natc a-0eo the Ru easy is located. q OR NOT KNOWN OR SUSPECTED TO EXIST IN YOUR, peon nedLu,Eho z en mtl�ilinuAemnnem vh dl be n�uriiing Jeli�cn.•J aloalthc FAVOR. YOU FURTHER AGREE THAT NO CLAIM, applic,ble pang n(Ihr address set font,in this Agreement or to snch o,hcr odJress as LAWSUIT. OR ANY OTHER LEGAL OR ARBITRATION a,v party may Jnslgwtefrum time to lime b}'wrinen name to the other pany. PROCEEDING IN CONNECTION WITH,ARISING OUT OF,OR S,C. U tly.V.. After lerminmion ur nxp,mtion onhis Agmemem.an�pio"oons IN ANY WAY RELATED TO THIS AGREEMENT MAY BE w'Aich by mcv namro arc mtendN m s,rnve weh n+mmaunn nr unme tau la shall 'unicc,mdudin•fwithnnt limituvpo),S�:c,i j,$.1 L, 4,J�(V,IX,mA 19. BROUGHT. COMMENCED OR FILED MORE II IAN ONE (1) il:seMT.RADI%.rrv. Ir any pm.naud al ,d> arcmr,rm Fdrm be�nvard, YEAR AFTER THE INCIDENT GIVING RISE TO SUCH CLAIM. Prnhinncd. or olh<rxise unenforcable by an adinlator nr coon of comperm YOU ACKNOWLEDGE THAT WE ARE RELYING ON 'THIS tJmtmcdhnni{txhm icg mlth cniun n Tea 1 em�ddln�ald Ir:oluhiied,umanenl'omdbl. ECTION 17 AS A CONDITION AND MATERIAL n'mall ntber rcxlxms this Agneemrm shall rcmninmlFll4sa and die}:prnvidn•� D MEN TO ENTER INTO THIS AGREEMENT. Aovrrer,that iRvry such provision may be,rode cnforcoaMe by limitnunu Ihaenf, iB.INDEMNIPICATION. To the fullest extent permitted b tlur s°ch provision shall be donned to he so limited mid shall bi•mdomeabk m the P 5 x man extcm pp•Imiard by applicable Inw. applicable law, You hereby agree t0 Indemnify, advance expenses, 2].COUNTERP.4RT5. Thw Averment may be executed in one or mare flltd hold harmless US and Our affiliates, directors. eat}�IU}}'e¢S, cnumerpoas,and all such wunteryarts shall he dtimed m cnnstiu,k one mewmcnt. agents, contractors, and Our SUCCeSSOrB and assigns (eaelt, a A lacvm,le or pnrtihle dwumnmt format t"pdP') shall uranitulc an onemal for ppwpoxs harrof. "Covered Person') from any and all third party claims, actions, 2a. PUnI.ICI'1'Y. You hereby amhome lJs to uu Mbur and Your Prnpmy'n voice, costs, expenses(Including reasonable aromeys'fees and execrises). photugrop6,vidro,and IiAeness in pool meJ,o.radio,1<lo'ision,c-maih v and mcdi',, damages, liabilities, penalties, losses, oblivanons, injmics, detllands or'J cerials,and any audio or viJnrtmording;yrnridedthat\Yc ag,ce that%V ill d non ehs lose an of Yuur persamlly denrty ne mlom,auon r cr.'Irt ass prodded n and hcrls of any km or nannz in connection with.arising out of,or sa_i n z((')1 Pon xwve snit mresv release us`for any Osp t relame a ar ar,smg in any way related to(i)Your breach of this Agreement.or(li)Your oat fifiw"Seauan_s. neghgenee or willful misconduct; provided that Your 29 PRFSC-FEN AND OPT OUT NOTICE. THIS indemnification obligations under this Section 18 shall not apply if "PBASED ON the harm or damage that is the basis or third party' damr INFORMATION IN YOUR CREDIT REPORT INDICATING occurred while one of Our employees or agents was at Your Property THAT YOU MEET CERTAIN CRITERIA- THIS OFFER IS NOT and such harts or damn c was solely caused by fire active negligence GUARANTEED IF YOU DO NOT MEET OUR CRITERIA. IF or willful misconduct ofsuch employeeor agent. YOU DO NOT WANT TO RECEIVE PRESCREENED OFFERS 19.SUBROGAT•ION. You agree to release all Covered Persons OF CREDIT FROM US AND OTHER COMPANIES,CALL THE from any claims of any parties suing through Your authority or in CONSUMER REPORTING AGENCIES TOLL-FREE, t888) 567- Your name. such as Your insurance company, and You agree to 8688;OR WRITE: EXPERI.AN OPT'OUT,P.O. BOX 919 ALLEN,, defend Us amtnst an, such claim. YOU AGREE TO NOTIFY FX 75013; TRANSUNION NAME REMOVAL OPTION, P.O. YOUR INSU�ANCE COMPANY OF THIS RELEASE. BOX 505 WOODLYN, PA 19094; EppUIF.AX OPTIONS, P.O. 20. AMENDMENTS AND WAIVERS. Its.A is,roem any ooiy he amended or BOX 740123 ATLANTA,GA 3031E-0123. 1 ol i i (i)any azpec[of the relationship between You and Us,whether based in contract,tort,statute or any other legal theory;(ii)this Agreement or any other agreement concemmg the su"' matter hereof; (iii) any breach, default, or term of [his Agreement; and (iv)the interpretation,validity,or enforceability of this Agreement,including the de[ernimanon of the scope or applicability of this Section 5(each,a `Drspure'"). Prior to commencing arbitration,a party must first send a written"Notice of Dispute' or certified mail to the ot�p—arty. The Nonce of Dispute must describe the nature and basis for the Dispute and the relief sought If You and We are unable to resolve the Dispute within thirty (30) days, then either party may commence arbitration. The arbitration shall be administered by JAMS pursuant to its Streamlined Arbitration Rules and Procedures avai/ab(e ar httpp://www.'amsadr.com/mles-streamlined-arbitration,the"JAMS Rules")and under the rules set forth in this Agreement. The arbitrator shall be bound'by the terms of this Agreement. No matter the circumstances,the arbitrator shall not award punitive,special,exemplary, indirect,or consequential damages to either party. If You initiate arbitration,You shall be responsible to pa $250. All attorneyys' fees,travel expenses,and other costs of the arbitration shall be home by You and Us in accordance with the JAMS Rules and appplicable law. The arbitration shall be conducted at a mutually agreeable location near Your Propertyy. Judgment on an arbitration award may be entered in any court of coin etent jurisdiction. Nothing in this Section 5 shall preclude You or We from seeking provisional remedies in aid of arbitration from a court.7 ompetent jurisdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE _ MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER 1 AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS t ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE "ARBITRATION OF DISPUTES" PROVISION TO NEUTRAL ARBITRATION. C.,a—.gsl1aniau: IIW E AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: ❑ 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,(ii)the Additional Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. These docum6nts are expressly incorporated into this Agreement and apply to the relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement,that We have signed the Agreement,and that You have read and received a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both You and Us,before any work may be started. E. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE LATER OF: (I)MIDNIGHT OF THE THIRD (3RD)BUSINESS DAY AFTER THE TRANSACTION DATE,OR(II)THE START OF INSTALLATION OF THE SYSTEM. SEE THE NOTICE OF CANCELLATION BELOW FOR AN EXPLANATT'ION OF THIS RIGHT. VIV[NT SOLAR DEV�JJ9F'F� CUSTOMER(S): -� By: By: i Printed Name: Printed Name: , , t_S ti tT Title: AA o By: Printed Name: Transaction Date: `I FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAZA,SUITE 5170, BOSTON,MA 02116, (617)973-8700 OR 888-293-3757. NOTICE OF CANCELLATION Transaction Date: AR No.: DYOU MAY AYS OF THE ABOVE DATE, OR TRANSACTION,LATER) OUT ANY PENALTY OR OBLIGATION;WITHIN THREE(3) BUSINESS DAYS O ANY ABOVE D TRAED F LATER) R)tUNTIL'THE-START OF INSTALLATION-OF THE-SYST M.-IF YOU PAYMENTSANY MADE BYYOU UNDER THE CONTRACT ORSALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY $SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY(20)DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION,YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER,OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOLel,DEVELOPER,LLC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO THE LATER OF: (1) MIDNIGHT OF THE THIRD(3 )BUSINESS DAY AFTER THE TRANSACTION DATE,OR(ID THE START OF INSTALLATION OF THE SYSTEM. I HEREBY CANCEL THIS TRANSACTION: Date: Customer's Signature: I. I i Cap ,ghl,.:013 v.,iry 911,1 Wleln� I X All NtiP"a""^'d. 11 ITn 112,11 ADDi'1'10NAL TERMS AND CONDITIONS 7. REPRESENTATIONS AND W\RR\\TIES. You reprren1, +vv,nn, red may t ',to this Agrcunent on wriuc once to Yin and Y. ill be obfgmed to u.r in., ht.f[h fall my sI ve nW o axl: 01 all ( ft vpanneY n µy to Es a n rum a al to lour D II 1S4)(+c reu i 'r II J snh)nt to e n bJ asm a I del ❑la.phoax ih •d I am Vic rf') .l the "'unionoft pe crt�5 )P rywr(rXl tithe tenter Pa troll by Pr pen,( } It full an nJ ex lu r c cwn i,p igl I,t Ill'i panel'i In)'Ill sls( P an statle Ater You cuaama �mimy atal nd lr Ndrsnsinat loatitath esect,tilmr l od,n8 and n , minYou anxYA f14herTraii tbasiynvm ,hsuvd ov ua-oNae�mvpsioifi,lh st An toYn on S } br+'e nen6 i have aJryl� pun s h rty` u J ais uas Ni.Aerep nem wail�dr vl(s,client Iha.pit peed monster 1 V o Pmpaly m Pn,pcny '�'ranal tt v Irna or other :nN an) Nrr aJ twr Ytu fuse desire mI n Ir Vn w lersLm l Yhel an nun A, mmsler[h'I : u a ice snnpl ul Yon rill lama eslmnsihle Rr prlean -r f i's m nppre nY[ s a m thisYgr e ra n rude by Youa ma«rmf beach 1 Your Ohli'rat re, 1 le 11 is \+r rat. \ i ,yn Ike uh d [h a f II Customers II. :lgre + l and a till S l i [ N reticule . tied f a S cum l a h. Wo, he ely It b Jcem J w-f -ref Your l nrperty unJ W4 xJl wads Ro th Your milk,no rprcunuuv sic o mmmes e. pt v eaprc iv r lonh m[ A n fur u, suae..O and he rs m t Tx Ihis Agiccnmm Pr rswmt m,hc reins and condition,of 8. Ot R sr RVIfES (a)h''etenn``• R ill ore 11 pen m ma male(, :u"naded Sg Ion 12�h)) to measure the Cnergy pro uc�U S} tun. Mc II all y p•'r romme,data b.�R'E_Ig OF DEF\UI r.,k' ('ugoina Octant, A Onion e.Orl,r 1, shall .,.idy or nice Our pcnmmcl to total the dam. We will provide thrs Jam,o You mean the ocannence o[any rat n r 1illow in:�Cclir failnm m awke any payment upon Your reasm,nble rcyuest. You agree to ntle,Our personnd reasonable recess to an Ihis A¢rcemcn[within tar(IU)day.o�when due and such Gilun is nut cured Your Property to aullal such dam. At Ctnr discr.[ian,\Ve may k>i Iur nauiacy Of the within m,I IUI Nrys otter R'r I,•ire Yon wnten notice of a'uch I:nla{p;(ill your failure gedirntnnce inners from time to lime. If hang indicate,the t the meter is inaaumte to perform anv,obliganion under this Agrccmen,and such milme is oat cure[within y more thnn'J-59' W + II Onpn,and real M1rme the m[r at n r p<xl m\o 'My n ( 0)Ja s a1&\Y You alien notice of such Iv lure (in)You deny Its. Ind nil make retroactive udjusm, us t Y m r p. m nts based f n corrected meta data Our contra ton I r agrns,governmental authorities,or the I-Wity ua,,, to Your far the rental ofwch tea r y. 11'he s is, gnmbl Foray reason,including Pmpet d slab ..... e s s II •tee, obit Thin)) ``30)Jayy' Iler We,give You Yaur induce n+raw win eking bmaJd red in[cmc,or laevicvl.crnnmUrns,We xrilI n ounce of the faiun w pro,Wp s ah access:(iv7 Your bnnknpi insolvency raw char,,"Vol f r the Shuldoax,I'a))nem h)C v ai LL .y�K. B the 5 rein or admission of You man hrt tarn)Your d bts s[IO nature,-or O Y Pro pen, de nagnl ter Jesu< d by,fin;vrnn II xd r nhym ck I r o[h r d sa.'t t o a td nY bainou 9 sa b<l trial fonelo ten pnxear g (b)R n odic,fur C u romer Oef I. if (rn C: all Leon'1 erovt 1 by U r W II) on,ptl} rep 'r red C m limit occurs We m,y rc', an ,I Ih fi, rag res rent" [I d g d pumons rl Iba Sy t n uy m ssl rc t m yOnl orktn O terminate N-Agreement and demand T p the Default Paym n[;Ili)Ira the ro Ni m It ttr Avste n n dvmayeJ o Jestm�A by t(:1smIY}k+ent not cd h Syoa love ten Yet"Prapcn} but d n 1 aac>s to and use o!the Eis ry it Oar nsurmcr� Wit may, aY Our olmon (j pv r and rcstare[br Sy min to eabd produces,vvhrah may be oa ne,ed and soul of Our election;(iid disconnect Or lake rocking corJ[lank or UQ ieninvte this' Aerecnum and, at Yam:clrcuon, rather avk me System as penninN by applicable hot:(e)place a lien on Your Finnerty; com'ey the System in its then-exisLng cmutiiim,."As Is.M1ere Lc",la You far no (rF rn arc a collection agency to collect naynienu'boom You;(vii))rcpan Yuur default udNlional conedemtinn or remove the System from 1'ovr Property. (c)D'sconnec i n to eneii npanmg agencies;and+or(vie)ezacne env od,er remeJv available to Us in f sum. Ne may�ame the Sysem to he disennmemd firm the Uniny.c nmII this Aer vocal or under applicable lose. (")Seller cfmd[. A"Biller Defuulf'shn11 I try reyutrc wch Nscnvnminn m W'c arc rquved w Jo sounder app xabi.law. mean the naurrrnee of any of the fotlowtng: It ter allure m perform any,(Our 9. VOUR DITIES. la)p��f,he Svaam. You shall wr the Enary for r}tderirl material obligations under ibis Aga amad antl the eff«I of such failure is nor vmA purposes rank vnJ not Floe ,iTny swimimme p<wi. AI all Yimes,f ou shall ensure• ifi in thin,,001 y}1 aMr You a v US Ritter]notice of such Failure:err(ill Our hat [he Prsipny rein"its grid<mmttlyd to a Uiilily. (6113nxNbnrd Intemn hankmpte..,insohericycrndmis,4vol Our inability topa ur y0dshn os they m[me. Cannec,ion. Y pus ain't tProw,d11ht Svs cess to acss to maim,mg tem with malmon,ac (d) Remcxli f r 'tiler Default. If a Seller Default occurs and,s immmom• You imanetconmmtion withonewited ENemM pnnand a:md.mi'lectricll oullatitYour lFa cm anJ guest removal ofthe Systan fv., Your cost lCYou fail lO mhinmm bnsWhvnJ imemn nrdmvtcalcmmar[loaf ralp+eenadaf Prupcny;pnd/or fiD avatar As pmvadcd below,exercise any Mhcr rem Ny avroiI MR to time,i We may charge Ymt the Shunlown Payment (d S'sil Attentions Ynu shag you in this.4gre...t or antl,,applicable law. Notwithstanding the fgreeono,You not()alter,repair,or otherwise mMif any cumnoneid'I e,ywal(collecliaely will have tea nuht to claim causes, as a result of the to annation of this Agncmcnt. "Allimodurry`):and fill lake any action that amid wind or mapav any"arrant,rc sbuil wept Fur(x)tls actual Costs to remove the S}stem if We tail to remove the System ,V the System. You will be rev:pensh,i,It,,any damaee to the System that is caused it from Your property pursuant to Sanion 14:and(y)asy dmnages w You,Properrtryy any lime is You r Your_•nests, miters, cmamicwrs, Or:repels. (d) Praoe0,. esullbag from die removal of trie System by Us or Uor emavaaor. fe1 Defindl Altenlume. You shall lit Vim till tees on Your Property,nofmsmll structures ten payments. If this Agreement is mmtinated for any reason,other than pursuantt tT Par roolruol,and take odmF tenantable steps to ensure that shading of the System rs no nR^icr uFC,mallmion,Sa;uS I6�,Or a Seller Detain[,You will pay to h�the fault t e se turn a„the Imaun uo,Dar a tl O i m t qgu M co Joan and repine Payment The Dejaul/Ygm ri'shull he a amount equal Io'-- Dellars IS7 Prr the roof and all clam al )sI m,of Your n ro�nv ( 1.1uth nza,-ns. Y u shell art sr Ilea subject to red ,ten of five percent(5.0)per ca (eg m vear 2�the obuin ham Yaur mong g torte ow - euun. ,}T,mut ill v n Defn h payment will be S,68 per au osiall d) plus appueable nixes 1'mi Iigee interest n Your Pmpeny ill nptheriu[iana necessary for Ls t nsm operate.and that the D•fault Payniu t fiur1Y reflects the aloe of oho Svsmm,and,m the eau of o manrtmr]the System. Y our ad...to Obtain these vu limrzvuons in a timely marine, Customer Drepresentationit is a fa representation of the damnge,and losses that We rxnat to may [esu t in termination Of this Agreement (t)'I'nxcs. You will par ell rose cur. After You pay Io Us the Default Nyman.We will music,oxnershiis of the asacwacd an to mislay "min monfi:mon or a,.tuu`.Tau,Svsrem. metudme any System to You on an"As N.Wherrc Is'basi, general excise or sales m, on the Enmpy preJuced by the System. We shall be 14.TERMINATION. (a)Teme al b�y Seller. We may,in Our Role diure[ion. responsible I'm income tax andprnlxny tin assesuJ in mla[ion to Ck1r ownership of ["fulmar this.As,, (i)d poor ,6 the In-ncI1ae Date,upon delivery of written the System. fg) an e'. If You,the Utility,ter any povemmem:J"eery reym,es notice to You;Or(it)upon the occurrence of.Customer De(aoil. Within ninety(90) fnany.'ia,nyr to r.}s,en,a8entsinsmlNuon,Ynu shailpav Uur s)andord pens and days inner termiaanan of this Adeanen, odor dim,undo the cirtmns[ances m which i abor chmees:or lip tmu We pa)'any Ian.lee,ter other dmrgr in nlauon m the System the System is trvnsfemti m 1'Ou antl". et.'_.Section 12 or Seed n I,F'e will or Ihis A` mein fie, the In-Service Da¢. then You snail use rcspuvahle to remme,the System and restore all ran op pemevanrns m fire m Rs. If We reimburse Ds fur sarh nrv,(.or n,hrr chit trecepl for income nnJ property roses clect to termoun, this Aerea ram, We will have no farther liability to You. [ha,van Oar respnnsihili,y nailer Salim ). (h)further Assiruaees. Upon Our (b)Tammaiii b}Q6lomer. You may terminate this Agreement(I)pursuant to the ntryes,Von shall pnnnptly>tgn an ,mum(i)tiny npn nauo� n,a_rzeeninu or other tens o tt he Notreeol'�aclap m or(rra uppoon n Seller Ih`hmdl. documart nccassary Car.Gs 10 obmm:u))cretins,rebates,tncnnivo,allowances,or I5.SYSTEM SII1fTUUW'N.S,fe} Safc•N Shmdoun. In addition tea Our dJ1[m shin mrthliuntes that ore u[tiibutcd,al amcq ur r,la«d m Ilan System,tlrc Eric v, or doxm the Sell.for maintenance, a may s ut own the System if We imsmubhv rvrronmenul atMbntes Nerrof 1a,lieeuvely, the "Spatem IrrMmne"); (itl-any believe that Pmpnyxconditinn$arnaivniM of persons on Ne Properly,ohich arenot lxmnits inse¢onn lion,act metering varL¢mrnis,pnJ oNcr dxnmens rean al by under Our control, hither or not under Your ean[roi,may lotvfere with me one the W,(hy;and(till any d,xurmn,naesuan m vend liar owne/shiP,opens,in the opPecration ol'thc•System%••Safety ShurQown'I. Dumbf:[hc prnt theme of o Barely S)siem anJ System Interests. (i)ITi o NBiity You shall pmmpl v nntsfy L"if it Sal uldm,a.You will nay' s the Shulduwn Nymem. (bl P m rtrt -a�ealyd. In tl,e \ou notice anv pmarn err thing inter cone a'itF I e upem[inn of[he Svstem;(ii)Your event than You vacate Y our Proper])for any pefled O(time as v result of o evrnnhat . _S parts-lua a�wJ a e pcvvu.�nlatwos.a a,icumbsaacac.thnt_m:s, pr I neat. l:wm Alvicu[..lan,i_urS.jkWvaul,,.]uit u,LL.oatn full vUa fu,aillhe. p I'cr System pen ti (ui/You mkc anv mereenc}action a th nspeal t L,o the L'nr,t, p,Wuced b),h S}sl (c)Interconnect i D.id v fan If mtcrtann r:uon 5yysr Y fadurc to pr mpilp notfy is of suite matters shall he a Gustome iih the Ui hty bosom S f ael al u r ooYO n Poree\7ajcurc Ckfaul,under Section iJ� F:vent,ter(U caused b'or related m Qr u exr iced vuiOn or inaumn We Nat the Ire.SALE UF'SOI, ESE2OY'. (m Stele of Elydria Iv. n<cimong w[N the In- Svstem c no longer ante to pmducr elect/cm or transfer decVicity m Ynu or to the Service Dina, We will sell ,o Y'ou undlou�e,I1 hiDTrm Cs all of,he Enagv Utiht}t V'uu Roil' paZ lis ,he ShntJnxv Pa:mrnt. ldl.$g��ulda"n ppavmcnt The prrJuaJ by Iltr Sys<m. Title w antl risk o!loss with mspec,m,the Lner< shall 'Shmdown Yaynrcm sbali equal Wesum of(il payment.o I.. anv-Price that [rarnfer from Us ro 1'on rat Ne palm whuc[he System is_in[erconna<led r Yon would hart male n,Us as dascnbed in Scelmn 2.A.for[hr En that would ' Propene�.dcirical wuine. Energy from doe Svsem soli hr delivered to You in have been producal by the System during[he per—iTFtFe shutdown:(u)the value m emnphancc with siT requimmems of,hr Niliry. (b)Pavmcnts. 1'ou a¢rtr Yhnt the Us ul,he System Incentives that We wuuiJ hove rere)veJ wish aspect It the Ene,ey phligntien m yy at/ amaum due under this Ayreem vt shall use alxuiute a d ibm the Sysem Ronald hove pnduceal Ibllowim such shntdOwn;and(ui)allplicnMe umm�dmm�al,nnA sAali not M1e subjmuo any abvemenl,dcfenu,Munnaclvim..story, taxes. Un,minanwn of the amount of Enemy Ig1ut would here Teen produceA during recoupm<n[ or nxludion. Y'mi antl We nnfae ,hat vii ammv,Ls payable be You Ihv lxrioA rf Ne simidovvn shall lx hand(A}Aunng,hc rem war agar tin In-Service uevmder shall be payable in all events mdudme by\'anv beta and psmm. hxcy,n in Dale,ten eeimoud levers of pnxiuc[irm and(BI altcrthr fim year aftertue in-Serviee pgm,i¢N ivy Ne Notice of C'uncdinhom Yon hereby waive all riehu You rrwv have to Dam,dasrd On acmOl oprrnuon of,he Svstem Janng the same period m Roc pmious -iat or cancel thus AFrcemcal,to revoke liaepIance of the Svstem,or,J and a year. II a shmdawn pununnt In Section d or this Sa'h�i 1"connnues far one iluildred secant inla•,as,in the Svstrna. Ic)Li I,,on )hit+abutito_Iki�iv'[. \4'E D(�NOT and eaghry(IR(I)Jays or lun•�r[Oc may in t(h r Role discrcuun, tmmnate this WAR Ni OR GUARANTEE TF AN EYERC:F I'RODUC'ED BY Aercamad and flc�oin,You tonne the Damof,pmmam, THE SYSTEM FOR ANY PERIOD OR AM"COST SAVINGS. We are not a utility 16. FORCE MA.I SURE. If Yon Or We are unable la nor umt as ofthe obligations Ill public service companyy mal do nut assume any obiieations of a utility or public nailer Nils Agreement because of a force Majeure Isom,ssI'll WTcctcd harry sill be sen ice"".Pa., to susppl, Your energy nymmnam. We are not so jcc,in rate escusd from xhmncr performance is aRecmd by the Force M1lulcure Eventp oviJed ,eviev,by govrmtnento awhentics. Dnnng ibc Tenn.You undersmnJ dint You nwv that the aspersion ofsuch abliggmiuns tea of a,,grimy- oppt anJ Drum Immerdumtiun. regmre more elate anyy Nan the System ,nay en.—de. if You neeA fury such than is reggired by Iha pore NI'a rare head. "Para,Afu/eure Evew'shaJl mean ii aJdniento cc,,.[hen YInt shall be,solely rexpamsble v,obtain sueh a., I tram Nc area.conJmon or cacums aute�evend Ne control ofthe affected puny wlumb,V the Utility at 1'nnr iva exenis nl'Jue furesighl such Wrty roulJ not nasonabiy have bean cspxmd Yo:noith 11.OW'NERSRIPOFSYSTENf. (a)Our(Tvnrrshio to the Sytem. We shall own uaj,luthbythecxentserf Jadilipala.ad, uptyvithoat fault audbumbie to it is and bold all inn em rights in the Svsten ,l a System nrnrc�s�.YO.shall have no tenable I.overcame,including,but art limiteJ I.,action by a eo>emnmmm)authority. property,inters,m the Svstem or the System Interest,except tie(i the Enerr'. flan the faJnrc to act on the pan oT any govcrommml authority or the Utility pnami<kANal , tlm System gnaemtes.and(ii)an'cmins or prymcnu:rvmiable un�r Ynur Utditv's such a Zion has ban imply requested and diligently pursued), failure to obtain or i "Cot metering'proerun for the Energy that I e.Sisson warites. Ynu ayrtr t keep mainmin a penn0.liaxne,consent or appro,al Rrmviand Nat sueh piny has made It,,Swem and.SYnem Interests free him.ail Lens amfencumbrances. it I'e. ml timely and masnnvblc commercial e2bns m outntn and mainmin Ne scene), lauor Prorimyy NNmmv of dac vacm. Nw im,vp ine the mimic,m abich the S,slem is Jispme,strike.wnrkswpPage.sloe-doxn,Inck.ouL IlusJ,eathytiakr.fire,ligliming mmchcJ to Your]rra ,a t,.norvny lawn fling by Us,You and We henry agra do, wind,epidemic,war.tprtetum,no[.economic sanction ur rn,bnren,rivet dIs ahana. the Sierra and the�,ter,harass shall rcmam Our solefpersonal pot,r t,and shall act nl gaW, unarailabihly of eleriiciry• from [he U'tihly. quq,ma,[, s pplies or not li AeemeA mcharmterized as n"linnet"or anv pan a 0e"reap, v.dmu moos nnndnem,Power or wlvtge sueEE cause)by someone rtiei,ban the atLxmd Pan}t err v bed lined by applicable Cox. 11 is fnnher anent that the'smllmion at do, I:ailurc of c<ryippmein nut unlacafebv or Roder the wmml olthraBend party'. S>>ac.shall not be x repair.remodel, it, lion.conversion, mOdamimtion of,or 17.LIb119'A'rION Of LLNRILTfY. Yau unde[smnd Nar. (ai We arc not an insane v,lai[ion m.Vow Property. fc)Gmnt of Access You hereby cram m Us and par of Your PropcnY. ps:rnnal property,or personal safety of persons m or ten Your a,mlo ccs .'cots,and contractors 1 e n 11[,ages fund use Your Property so fl n Property.(n)Ynu arcs Fete n Tonsb a tI r nro Wine anv unurmce xilh nsncxl la We too (5,,:mlh operae,nod ma rem III-, lhmn•heat the Terra,Luj avCone four PrehIerty anJ its 'm tent (<)Neu u I Yau j,ay i,Us is bnseU only on the Our nJha I, the AErem n[ vd ,hc Symcar, ioul it)tilke an, litl t n slue of[hela xy p- eJb der Vys,em anJ nM on the i f\0 lnpeny or real wily 0a n munesuou 111h t-I11116a. inaldluallal. ammumn IL co 1 nu.- Idllfe S.t n y ni nl rays nperete properly[ and rims;k9 it mu m n n cpair,t 1 fd S} 1 m qq k �i 6 n ht d a teas to 1 I s dill cult n I«room t ud ten the,air a oi'[hr ninon", sic of Ih•Svstem,hat Proprty shall wnstit to a licevse m upleJ wiN vn totem",anti shall be an...cable for mi(dn he 10Y1 or ApsmveJ'f fun Syslom orris Io operate proncrlY(f) t is difficult to [irne to remove dcttt rim re I 1 J imce xha(Portion.if tray,of im prolarrt i f p rsnwl iuiury or [he Sy tun n,h n l I l th T fun Idt N t - I S,.I 0 h p I'm amhona Bath odd b proximately caused by Our fadurc to perfn n.0 ne,di' ce,or v Us i mvkc hhngs Ind nrorJ'acs w ih ,euvemnten�n,ilTwnte1 us may be failure ofth+Iliac..or the s 'um,instillation necessary io provide notice nf0ur axnership in[hu System end the Svstumlmvnsv, NOTWITHSTANDING ANY BREACH OF THIS AGREEMENT, and(hsr right,o access Your Proprny, Unan,emanation"(Ihis:\'irrpm al.cacti i sad,ilia,,will by nnninmrd. YOu undcaund,hat Ibc System shall b,marked and ANY FAILURE OF THE SYSTEM. OR ANY NEGLIGENT ACT idenuflal sour ivy THATCAUSED ANY INJURY OR LOSS IWI)FTHER In 111 on PROPERTY DAMAGE. PERSONAL INJURY OR DEATH 1.0 ll va to (i h 1 r pm this \ t—d'-S[e the S a late,..l n't,aumc s ANYONE, WE AND YOU AGREE THAT, UNLESS SUCH with wYo rc � a red v�a i „ If I s e r i Ou gi t. i J iba \gear t lA'e+rill hoop no htnlrrlab lit ter oMigalion,nder INJURY OR LOSS WAS CAUSED BY A PARTY'S GROSS thi- Ace n n rynthc IT toss of hsgnt (bit sler rat Pro cm. NEGLRiENCE, FRAUD, OR WILLFUL INJURY. SUCH rot R II p de Ls till Ihtrty(10)der poor wrimn nonce m a propuse Ice PARTY'S LIABILITY ARISING OUT OF OR RELATING TO simple mJe rat Ymi Pm,-,mv Ihis wmlea notice Audl include the manic of the proposed purchrsur err Imnsferca("Yrnpem Tranxfe.ed'I and the pregraewd ante of THIS AGRF,EMF,NT SHALL IN NO EVENT EXCEED THE ulr ur rmnsrer. You will also Pirelli,nnyaddimrnot inf,nnaton ,;i,d,ag 1'mpmy DEFAULT PAYMENT. YOU AND WE ,AGREE THAT THIS 9"mnateree that We rusrnably request )'I. sv0I requan that Propeay'fnnsicrce AMOUNT IS A FAIR REPRESENTATION OF THE DAMAGES 1g e m wrung with Us than Rrojreny'rmmsicrec ,Ill anal Voiu ohit'.ii,ms under i h 1 Agreement Pi pen•Tranvfen,shall cola into sus 11 nyrc I v I as Or hcfm.the TI1A"f YOU OR W E EXPECT"FU NC'UR IN 1'HH CASE OF ANY date Yatr Property is stlil. Amman vel .ifIVe delennin,thin Propcny)'mnsIe a,is INJURY OR LOSS HEREUNDER. 'le t udcyumcly medltwarthy to amnne Your ,bligantons under Ihis Agicament, or NO CLAIM SHALL BE MADE BY YOU AGAINST US OR ANY 14npc'ty TratibR•mc refuses m n e your o�hlivotimrs under,hB Agranncn,. We cum 'r 4 Brentwood Ave, Salem MA 01970 \_ :21 E m JUNCTION BO%ATTACHED TO ARRAY USING ECO HARDWARE TO i 1 KEEP JUNCTION BOX OFF ROOF I m i 20z �a(n0 U l' R OF 1"PVC NCONDUITBTI 'E FROM JUNCTION BOX TO ELEC PANEL 1 r^ VJ PV SYSTEM SIZE: 10.965 kW DC I �- I I O N •G e I I I I 0 ^m o a m � U a (43)Vinoli Enemy YL255P-29b MODULES WITH A I > j EnOhase M21560-2LL-S2z-ZC MICRO-INVERTER z 1 MOUNTED ON THE BACK OF EACH MODULE 1 m w w z m PV INTERCONNECTION POINT, cwi LOCKABLE DISCONNECT SWITCH, I y H Q ¢ ANSI METER LOCATION, z z p 1 8 UTILITY METER LOCATION I SHEET NAME: L- - - —-—- —-—-—-— - - - - -—-— - —-—- - Lug � a V SHEET NUMBER: PV SYSTEM SITE PLAN 4 SCALE: 3/32"= V-0" > 0- o v to m d», 0 N A< 0 r) C00 n C A< N >,0 A A;J C 0 y�O rC N� N Cn 50 N0 r� UO by 00 Oc C m H o Flo Co m n < No. o D m Cn w w Cn m 00 n T O C H m y m Z m m A Y CS DI NSTALLER:VVNTSOLAR . . [1n1) Smith Residence Salem,MA 01970 P\/ f o my ROOF y MALCENSE.MAHIC170848 817 4044128 n� V �� Y. solar 4BrenMoodAve V G PLAN DRAANBV:RBR AR4059721 Last ModifiedMooditied 4/9/2015 UTILITY ACCOUNT NUMBER 50585-32002 CLAMP MOUNTING a� SEALING PV3.0 DETAIL WASHER c N LOWER "0�ma SUPPORT N o S g aQ z (if El mdz tiff....... •r m O PV MODULES, TYP. MOUNT .. �P � OF COMP SHINGLE ROOF, FLASHING E PARALLEL TO ROOF PLANE 2 1/2" MIN U J 5/16"O x 4 1/2" MINIMUM STAINLESS fYR PV ARRAY TYP. ELEVATION STEEL LAG SCREW �7 NOT TO SCALE TORQUE= 13±2 ft-Ibs O CLAMP ATTACHMENT (n NOT TO SCALE •o a CLAMP+ ATTACHMENT CANTELEVER U4 OR LESS 9 COUPLING j L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. e m PERMITTED COUPLING 5 m a CLAMP+ CLAMP 07 ATTACHMENT SPACING CLAMP F w COUPLING PHOTOVOLTAIC MODULE < p > ? w a a m i Z h ¢z z__ m n SHEET NAME: L=PORTRAIT CLAMP SPACING Z LU Q 0 LU ECO 2 p COMPATIBLE SHEET L=LANDSCAPE LAN SPACING MODULE PV SYSTEM MOUNTING DETAIL NUMBERCLAMP : MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE NOT TO SCALE > a_ Inverter Ratings(Guide Section 4) 0 Conduit and Conductor Schedule marter MakalModel Enphim M21560­2LL-sex-zc MODULE DETAIL ,Max DC Von Rating 45 Vote 1. be—o•n ore di •wcomm.o� coon.,Two comail sa• Max Povar®40-C 215 Want 1EPlx­wai IffixB2 12 AKGx I Cad I BA-OxeM Nominal AC Voltage 240 Vole 1 B­Ccppn ardour rEGPacEe) 9Av.G - .ee �A, N Vingli Energy VL255P-29b Max AC currant 09 Amps 1t. wA Pvcp-I. O SOLAR MODULE Max OCPD Raling 201 Amps a THM 9AV.G P.Ic u �^, ,so p Max Number of PaneklCirwit 11 PJC W N 3 9AVTi 0'` T HM2 V K NOTES FOR INVERTER CIRCUITS(Guide Section Band 9): > TUW*1-x-Gmure 6AYXi we Q'-�m m 1)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS .Q m Enphase M215-60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? PV Module Ratings Q STC(Guide Section 5) .E i MICRO-INVERTER AT YES NO %NA Model MakeMli Yingli Env,YL255P-29b cr NEI Max Power-Paint Current(Imp) B.32gA.pa m d EACH MODULE,ATTACHED 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Paint Voltage(Vmp) 30.8 a m 0 WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS'! p O YES NO XNA pan-Circus Veit... Vaq 387 �e Shan-Circuit Current(Im) B.BB3.)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Series Fuse(CORD) 15 BASED ON MAX CURRENT ON NEC 69053 SIGN OR OCPD Nominal Maximum Pov2r at STC(Pmax) 255MICROINVERTER CONNECTION RATING AT DISCONNECT. Maximum System Voltage 1000(IEO)/500iTO ENGAGE TRUNK CABLE xi SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature Coefficient -032 TO INVERTER OCPD AMPERE RATING(See Guide Section 9), J , 5.)TOTAL OF 3 INVERTER OCPDR).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WRING(Guide Section 6 and 8 and Appendix IT; PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expecled ambient temperature based on ASHRAE minimum mean extreme BARE CU GROUND NEC 690.64(8)(2)(a)9 XYES NO dry bulb temperature for ASHRAE location most similar to installation location: -19°C (GROUNDING _ (GNG ARRAY) Signfi(See Guitle Section 7) 2.)oisturecontinuous ASHRAambientlocation nm most sire based on ASHRAE location month 2%dry bulb temperature for ASHRAE location most similar to installation location: 39°C Sign for inverter OCPD and AC Disconnect 3)2006 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the 0 United States(Path Springs.CA is 44.1^q.For less than 9 currentcanyirg conductor. Solar PV System AC Point of Connection in roof-mounted sunlit conduit at least 0.5-above roof and using flee outdoor design AC Output Current 38.700000 Amps temperature of 47°C or less(all of United States). Nominal AO Vinalge ii Z401 VOgs a.)12 AW'G,90-C conductom are generally acceptable for modules with Ise of 7.68 Amps � w PV CIRCUIT 1: 14 MODULES/PARALLEL or less when protected by a 12-Amp or smaller fuse. THIS PANEL FED eY MULTIPLE SOURCES N (UTILITY AND SOLAR) b)1D AWE,90°C conductors are generally acceptable for modules with lac of96 Amps m Or less Vmen protectedb a 15-Arnp Or smaller fuse. OQP 4 • • • O O16 NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY `a E 1.0 ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR S • • • S S 9 on I a PV CIRCUIT 2: 14 MODULES/PARALLEL e ENVOY BOX ? mon m of m o Nr LIE YpAt toQdo MURRAY POINT OF DELIVERY ' z w Of COMBINER AND INTERCONNECTION w w wbe___ ___ \'LO POEL,25A/240V SIEMENS Q ¢ ULWO04NR 60P/240V od to to <EQUIVALENT UNFUSED NEMA3 M ? ? p O\Fy lc� LNF222R OR PV CIRCUIT 3: 1S MODULES/PARALLEL \\T°L METER NSI EQUIVALENT SHEET METER NAME: I I EXISTING � 201 240V/200A LU < ,� \\\ zoA LOAD-CENTER J • • • S S I J60A SHEET ___ NUMBER' _______ ___ ____ \\ MILBANK VISIBLE/LOCKABLE 4 JUNCTION BOX bo \\ '3 10I A LE 3 'KNIFE'A/C 3 NEC 2014 Compliant WITH IRREVERSIBLE E \ EQUIVALENT DISCONNECT GROUND SPLICE \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 �J,J C D ' O m O O z Co D o z o m o N c y m N D y N Z. C n z O N O C x w m o x c z z O N e ee� r, i I� lie d t Kam, i a! et' i, aiP4Y 0 O 0 c M m m D y P u> N C 2 O 0i C �m A N N N Cm AX <O MO mN om 0 0 O 2 N M m CM ZN NSTALLER:VVNTSOLAR Smith Residence KM DESIGN M mINSTALLER NUMBER:1.877A04A129 ��Sj solar PV 4.0 p I LOGIC m MALICENSE:MAHIC 170848 v u v u a Saiem,MA01970 DRANM BY:RBR AR 40591 Last Modified 4/912015 UTILITY ACCOUNT NUMBER 50685-32002 Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: James Smith Project Address: 4 Brentwood Ave,Salem MA A.System Description: The array consists of a 10.965 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(43) 255-watt modules and(43)215-watt micro-inverters,mounted on the back of each PV module.The array includes(3)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Pcofrbrium Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Eeolibrium Solar b.Product Name: Eeorall c.Total Weight of PV Modules and mounting hardware: 1810.6 Ibs d.Total number of attachment points: 101 e.Weight per attachment point: 17.92 Ibs f.Maximum spacing between attachment points: *See attached engineering talcs g.Total surface area of PV array: 756.11 square feet h.Array pounds per square foot: 2.39 Ibs square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (21)modules,(55)attachments 16.07 pounds -Roof section 2: (5)modules,(20)attachments 10.52 pounds per square foot -Roof section 3: (17)modules,(26)attachments 27.53 pounds per square foot viviW. sour 3. Electrical Components: A. Module (UL 1703 Listed) Qty Yingh ICnergy YL255P-29b 43 modules Modu c Specs Pmax-nominal maximum power at SPC - 255 watts Vmp-rated voltage at maximum power - 30 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Ise-rate short circuit current - 9.01 amps B.Inverter (UL 1741 listed) Qty Hnphase M215-60-2LL-S22 43 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 3 PV circuit 1 - 14 modules/inverters (20)amp breaker PV circuit 2 - 14 modules/inverters (20)amp breaker PV circuit 3 - 15 modules/inverters (20)amp breaker 2011 NEC Article 705.60(B) bintsolar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 12.6 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(13) PV circuit continuous current rating 15.75 amps 2.Overcurrent protection device rating PV circuit continuous current rating 15.75 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amo AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12-h) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Article 705.60(B) Adjusted PV circuit continuous current 22.1 amps c. PV Circuit current adjustment for conduit fill Number of current-carrying conductors 9 conductors Conduit fill derate factor 70% 2011 NEC Amcle 705.60(B) Final Adjusted PV circuit continuous current 15.5 amps Total derated ampacity for PV circuit 15.5 amps Conductors(tag2 on 1-line)must be rated for a minimum of 15.5 amps THWN-2(90°C)#10AWG conductor is rated for 40 amps (Use#lOAWG or larger) 2011 NEC Amde 705.60(B) 4.Voltage drop(keep below 3%total) 2 puts: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2. Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.48% The largest number of micro-inverters in a row in the entire array is 10 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.48%. 2.AC conductor voltage drop: =I x R x D (=240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#10AWG copper)x(Total wire run) _ (Circuit 3 nominal current is 13.5 amps)x (0.0012652)x(230)- (240 volts) x (100) 1.63% Total system voltage drop: 2.11% vivin4. solar EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 16156 Street Address Line 1:4 Brentwood Ave Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity:43 Array Size(DC watts): 10965.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 40.8 Ibs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load- Lateral: 288 Ibf EcoX Design Load- Downward: 722 Ibf EcoX Design Load- Upward: 765 Ibf EcoX Design Load- Downslope: 297 Ibf EcoX Design Load- Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar Plane Calculations (ASCE 7-05): 1 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 21.0 deg Truss Spacing: 17.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.9 0.9 0.9 Roof Snow Load 30.2 30.2 30.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 30.2 30.2 30.2 psf Downslope: Load Combination 3 10.9 %9 10.9 psf Down: Load Combination 3 28.5 28.5 28.5 psf Down: Load Combination 5 12.2 12.2 12.2 psf Down: Load Combination 6a 29.4 29.4 29.4 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 29.4 29.4 29.4 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 60.6 60.6 53.1 in Max Spacing Between Attachments With Rafterf Russ Spacing of 17.0 in 51.0 51.0 51.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.2 20.2 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 46.9 46.9 41.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 34.0 34.0 34.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.6 15.6 13.7 in EcolibriumSolar Layout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal O Clamp expansion and contraction. See Installation Guide for details. Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 21 Weight of Modules: 857 Ibs Weight of Mounting System: 182 Ibs Total Plane Weight: 1039 Ibs Total Plane Array Area: 370 ft2 Distributed Weight: 2.81 psf Number of Attachments: 91 Weight per Attachment Point: 11 Ibs EcolibriumSolar Plane Calculations (ASCE 7-05): 2 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 12.0 deg Truss Spacing: 17.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 35.6 35.6 35.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 35.6 35.6 35.6 psf Downslope: Load Combination 3 7.7 7.7 7.7 psf Down: Load Combination 3 36.3 36.3 36.3 psf Down: Load Combination 5 12.3 12.3 12.3 psf Down: Load Combination 6a 35.3 35.3 35.3 psf Up: Load Combination 7 -14.6 -25.0 -38.2 psf Down Max 36.3 36.3 36.3 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 54.5 54.5 53.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 51.0 51.0 51.0 in Max Cantilever from Attachment to Perimeter of PV Array 18.2 18.2 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 42.2 42.2 41.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 34.0 34.0 34.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.1 14.1 13.7 in EcolibriumSolar Layout G Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal expansion and contraction. See Installation Guide for details. O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 5 Weight of Modules: 204 Ibs Weight of Mounting System: 182 Ibs Total Plane Weight: 386 Ibs Total Plane Array Area: 88 ft2 Distributed Weight. 4.39 psf Number of Attachments. 91 Weight per Attachment Point: 4 Ibs EcolibriumSolar Plane Calculations (ASCE 7-05): Roof 3 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 30.0 ft Include Snow Guards: No Least Horizontal Dimension. 27.0 ft Roof Slope: 22.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.88 0.88 0.88 Roof Snow Load 29.6 29.6 29.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 29.6 29.6 29.6 psf Downslope: Load Combination 3 11.1 11.1 11.1 psf Down: Load Combination 3 27.6 27.6 27.6 psf Down: Load Combination 5 12.1 12.1 12.1 psf Down: Load Combination 6a 28.7 28.7 28.7 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 28.7 28.7 28.7 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 61.3 61.3 53.1 in Max Spacing Between Attachments With Rafter/truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.4 20.4 17.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 47.5 47.5 41.1 in Max Spacing Between Attachments With Rafterfrruss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.8 15.8 13.7 in EcolibriumSolar Layout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal O Clamp expansion and contraction. See Installation Guide for details. Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 17 Weight of Modules: 694 Ibs Weight of Mounting System: 182 Ibs Total Plane Weight: 876lbs Total Plane Array Area: 299 ft2 Distributed Weight: 2.93 psf Number of Attachments: 91 Weight per Attachment Point: 10 Ibs EcolibriumSolar Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 91 ECO-001_102 EcoX Coupling Assembly 50 ECO-001_105B EcoX Landscape Skirt Kit 10 ECO-001 105A EcoX Portrait Skirt Kit 4 ECO-001_103 EcoX Composition Attachment Kit 91 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly(optional) 3 ECO-001_106 EcoX Bonding Jumper Assembly 12 ECO-001_104 EcoX Inverter Bracket Assembly 43 ECO-001 338 EcoX Connector Bracket 43 ECO_001-359 EcoX Lower Support-Low Slope 0