Loading...
3 BRENTWOOD AVENUE - BUILDING JACKET 3 Brentwood Ave. f l i .5 tr .....tea. a .-:....,.... �u�a,e.......�... . _:e._'�, ..:,.:.✓s�:.uv�.r..mua: .r.a...w.:�.,.:.evmxa:ve..,.:n.��:ca�.e�...s,:: ,...:raara'tis�::ss,w.tw,.�.�. •:.i�.,, ,�.1..._:�..w� . i..:..._�.M;,.�...e.u.e',me�,._...� .:..�;m:. .»tea .,..n.n�. .._.�.�.._.,_ C"itu of �ttlem, masSar4uoetts '• ''o Public Propertg Deportment +Nuilbing Department (One Salem (Sreen 500-745-9595 Ext. 380 Leo E. Tremblay Director of Public Property Inspector of Building Zoning Enforcement Officer August 5, 1993 TO WHOM IT MAY CONCERN: . _. j RE: 31 ` - .ntwood Ave. Please be advised that I have research the records regarding the above referenced property have determined that it is a grandfather lot and as such is a building lot. Prior to any construction a lawful building permit must be issued by this office and any structure must meet all setback and parking requirements for the Residential Single Family District. Sincerely, / / Leo E. Tremblay Inspector of Buildings Zoning Enforcement Officer LET:bms �03 cl< Li 52 s The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code, 780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date pplied: 6 / N) Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION ( 1.1 Property Address: n _ ,, _. _ _I 1.2 Assessors Map& Parcel Numbers _k I.1 a Is this an accepted street?yes no Map Number Parcel Number r� 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check ifyes❑ SECTION 2: PROPERTY OWNERSHIP[ 2.1 Owner[of Record: Peter Dragon Salem ma 01970 Name(Print) City,State,ZIP 3 Brentwood Ave 9785673321 Pgi12539gmail.com No.and Street - Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ 1 Accessory Bldg. Number of Units Other ❑ Specify: Brief D SWIM 0 r osed or 2: 1 SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials) 1. Building $ , 1..Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $ ❑ Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: $ Check No, Check Amount: Cash Amount: 6. Total Project Cost: $ ❑Paid in Full ❑ Outstanding Balance Due: I` SECTION 5: CONSTRUCTION SERVICES 5.1 Constr4etion Stmervisnr Licegsr(CSL) 1u r try, I I 11(/ kk 61it M- _ License Number Exio ''Ddte Name of CSC-Holder ., List CSL Type(see below) kVu St .Y No. and Street - _ Type Description 11 'I' U Unrestricted(Buildings up to 35,000 cu.ft.) u' `1 R Restricted 1&2 FamilyDwelling City/Town,State,ZIP ) M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances I Insulation Tele hone Email address D Demolition 5.2 Registered HoQ\fie I{m,fp`r'o^vemenrt ronttractor(HIC) \ 1\V1 \1 t�V 1U I HIC Registration Number Ex iratio Date HIC Company Name or 1 gistrant N No.and Str t Email address City/Town, IP Telephone SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuan f the building permit. Signed Affidavit Attached? Yes .......... No ........... ❑ SECTION 7a: OWNEP AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Vivint Solar to act on my behalf, in all ma rs at v ork authorized by this building permit application. Peter Dragon 3/11/16 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this applliicc'ation is true and accurate to the best of my knowledge and understanding. G Print Owner's or Aulhibrized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work, or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC) Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at 16 .mass. oe v/oca Information on the Construction Supervisor License can be found at www.mass.eov/d s 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics, decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" • • e Avon C �� � .� �' 3301 North Thanksgiving Way, Suite 500 Structural Group Lehi, UT 84043 P: (801) 234-7050 Scott E. Wyssling, PE Senior Manager of Engineering scott.wyssling@vivintsolar.com February 23, 2016 Mr. Dan Rock, Project Manager Vivint Solar 3301 North Thanksgiving Way, Suite 500 Lehi, UT 84043 Re: Structural Engineering Services Dragon Residence 3 Brentwood Ave, Salem MA S-4808400 3.9 kW Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof Section 1: Roof section is composed of 2x10 dimensional lumber at 16" on center with 1x6 collar ties every 32" and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 35 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B, Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivi t. S o u r Page 2 of 2 B. Loading Criteria 10 PSF = Dead Load (roofing/framing) 40 PSF = Live Load (around snow load) 3 PSF = Dead Load (solar panels/mountinq hardware) Total Dead Load= 13 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 ''/2" thick and mounted 4 ''/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the Nation Design Standards (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 '/2", is less than the maximum allowable per connection and therefore is adequate. 4. Roof Section 1: Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four (4) spaces or 64" o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. 6. If collar ties are not present per Massachusetts building code we recommend that 2x6 collar ties be installed at two third of the attic height @ 48"on center. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. OF AScotttE ly `'v//AscSUN IL . Wysslin9, P No,5�507 MA License No. 5 7 Q9oF9Fe srEPe FSSlONAI EN6 EcolibriumSolar Layout Skirt c Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal O Clamp expansion and contraction. See Installation Guide for details. Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. U C N -0 o m oo JUNCTION BOX ATTACHED T N�¢� ARRAY USING ECO HARDWARE TO m KEEP JUNCTION BOX OFF ROOF m`E i �m O 0 u" Q I I PV SYSTEM SIZE: 3.900 kW DC 0 II 75' I 1 I 1"PVC 24 FROM CONDUIT �� I FROMM JUNCTION BOX TO ELEC PANEL I � I � I V INTERCONNECTION POINT, INVERTER,ANSI METER LOCATION, LOCKABLE DISCONNECT SWITCH, &UTILITY METER LOCATION n I 0 0 m o e o N � U z m a (15)JKM260P4M MODULE I j E > w W z Z w Z a a � 3 z mw ¢ z SHEET NAME: 3 Brentwood , Salem MA 01970 J n. SHEET NUMBER' PV SYSTEM SITE PLAN o SCALE: 1/8"= 1'-0" > d pA OZ C0 880 y 0 �3U Ns0 O a> MEN n D C r m 11 m o � O O m TI mti 2 o r z D No Z m ti m A # c 0 D i INSTALLER:VIVINT SOLAR • •�q ;m 3mINSTALLERNUMBER:1.6]14044129 vivo solar Dragon Residence P\/ 2.0 my ROOF Ky MA LICENSE:MANIC 1]0846 Y Y • 3B,MA019 V L PLAN I DRAWN BY:JV I AR 4608400 Las[MMi(atl:22212016 UTILITY ACCOUNT UMBER:1330&92004 � $ I U CLAMP C 2 MOUNTING SEALING o. ,PV3.0 DETAIL WASHER Wig¢ LOWERj SUPPORTmmz 0 yo 0) a PV MODULES,TYP. MOUNT —� (LOF COMP SHINGLE ROOF, FLASHING PARALLEL TO ROOF PLANE 5/16"0 x 4 1/2" MINIMUM STAINLESS PV ARRAY TYP. ELEVATION STEEL LAG SCREWQ NOT TO SCALE TORQUE=13±2 fl-Ibs CLAMP ATTACHMENT N NOT TO SCALE e C a •e a � D CANTELEVER U4 OR LESS COUPLING m L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. a, 0 PERMITTED COUPLING e, rc v CLAMP CLAMP S m o O COUPLING SPACING PHOTOVOLTAIC MODULE r w O a z E a w .. K K N W W Z m Z Z a 4n � o L=PORTRAIT SHEET CLAMP SPACING NAME: 1- M) ECO ZA - \�- Q COMPATIBLE 5 I- L=LANDSCAPE MODULE PV SYSTEM MOUNTING DETAIL LU CLAMP SPACING (MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 SHEET NUMBER: NOT TO SCALE CD \M a O Conduit and Conductor Schedule DC Safety Switch Notes: Solar PV system AC Point of connection Tag Description Wire Gauge g of Conductors Conduit Type Conduit Size AC DOE amont Rated for max operating condition of inverter Accodmg a Neo 19.79 Amp: 1 Solar Edge Cable 10 AWG 2(V+,V-) N/A-Free Air N/A-Free Air 6908(Bk1) NEC 690.35 compliant Vona 240 Volts Voltage Nominal AC 1 Bare Copper Ground(EGC/GEC) 6 AWG 1 N/A-Free Air N/A-Free Air s o 2 THWN-2 10AWG 2(V+,V-) PVC 1S opens all ungrounded conductors THIS PANEL FED BY MULTIPLE SOURCES C (UTILITY AND SOLAR) 2 THWN-2-Ground 8AWG 1 PVC 1" N o 3 THWN-2 10 AWG 3(1-Li,1-1-2,1-N) PVC 1" Notes: SE380OA-US-U Inverter Specs: m V� 3 THWN-2-Ground 8AWG 1 PVC 1" Wme slxeland breaker calculations dependent upon CEC Efficiency 98% Na=E inverter Continuous Maximum Output. < Example:SE3800DA-US-U Max Output=16A AC Operating Voltage 240 V IY a s� < DA. Therefore a 20A Solar breaker will be needed for Continuous Max Output 16A CmYj III SE380OA-US-U inverter. Wire Gauge should also DC Maximum Input Current 13 A 0 �'O be determined with 16A Max for each inverter. Solar Edge Optimizer Specs: m z ALL CONDUCTORS P300 DC Input Power 30OW n SHALL BE COPPER DC Max Input Voltage 648V Design COnd1110DS: DC Max Input Current 12.5A 9 DC Max Output Current 15A ASHRAE 2013 Max String Rating 526OW Highest Monthly 2%DB Design Temp 35.6°C. Module Specs: I..' 15 PV MODULES PER INVERTER=3900 WATTS STC Lowest Min.Mean Extreme DB -17'C dKM260PE0 M 1 STRING OF 15 PV MODULES VOC Temp coefficient V/°C O Short Circuit Current(Isc) 9.GOA System Specs: Open Circuit Voltage(Voc) 37.8V Y P Operating Current(Imp) 8.47A a Max DC Voltage 500V Operating Voltage(Vmp) 30.7V C S JUNCTION BOX Nominal DC Operating Voltage 350V Max Series Fuse Rating WITH IRREVERSIBLE - GROUND SPLICE Max.DC Current per String - 15A STC Rating(Pmax) 260W Nominal AC Current 16A Power Tolerance -0/+3% 5 •CONFORMS TO ANSI C12.1-2008 r - I�md �md m_ —mJ limd gym _ L1 L2 N \� SOLAREDGE P300 OPTIMIZERS SOLAREOGE IVI m $m 1 SE3800ALSR G o INVERTER' � U swore UNFU ED E ¢ DO SAFETY 30N2�BV UNGusEn 7 E ti DO SAFETY NEIM]OR 2CM w toi m ML SWITCH EBNvuErvr < � I 2BR EXISTING SHEET NAME' 240V/200A AC w Q �_ G LOAD-CENTER i K ^1 VISIBLE WITH 1-2 POLE 20A v.N J O L LDG. E L� Q HE NO SOLAR BREAKER 3 GISCONNECT 3 _ SHEET NUMBER: O W