33 APPLEBY ROAD TITLE V INSPECTION 2020 .s
RECEIVED
SEP 14 2020 FILE # a ern qy,20
CITY OF SALEM
BOARD OF HEALTH
TITLE V INSPECTION
Dean G. Luscomb II & Sons
288 Maple Street
Middleton, MA 01949
978-774-4065
Licensed Plumber #20285
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PROPERTY OWNERS NAME L Lt r C _
PROPERTY ADDRESS '��
,Sale- I
DATE OF INSPECTION s2[) rv� r b O
NAME OF INSPECTOR 1� a
*, Commonwealth of Massachusetts
Title 5 Official Inspection Form
�s Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
33 Appleby Road
Property Address
Lejeune
Owner information is Owner's Name- — - - a ----. - —
required for every Salem _ _ _ _ MA 0_1970 _September 4, 2020_ _
page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:When filling out forms A. Inspector Information
on the computer,
use only the tab Dean G. Luscomb_ II _
key to move your Name of Inspector - -
cursor-do not Dean G. Luscomb II & Sons
use the return
key. Company Name
288 Maple Street
— - -- - - -
r� Company Address
Middleton MA 01949
CitylTown State Zip Code
a 978-774-4065 S1848 _
Telephone Number License Number
B. Certification
I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5
(310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address
listed above; the information reported below is true, accurate and complete as of the time of my
inspection; and the inspection was performed based on my training and experience in the proper function
and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined
that the system:
1. ® Passes
2. ❑ Conditionally Passes
3. ❑ Needs Further Evaluation by the Local Approving Authority
4. ❑ Fails
September 4_2020
Insp ctor's Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board
of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of
10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate
regional office of the DEP. The original form should be sent to the system owner and copies sent to
the buyer, if applicable, and the approving authority.
Please note: This report only describes conditions at the time of inspection and under the
conditions of use at that time.This inspection does not address how the system will perform
in the future under the same or different conditions of use.
t6insp.doe•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18
Commonwealth of Massachusetts
p Title 5 official Inspection Form
+,, {'I Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
= L, 33 Appleby Road
Property Address '- - - - -
Lejeune _
Owner information is Owner's Name
required for every Salem _ _ __ _ MA _ 01970 __ September 4, 2020
page. City/Town _ State Zip Code Date of Inspection
C. Inspection Summary
Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6.
1) System Passes:
® 1 have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
2) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
*A metal septic tank will pass inspection if it is structural) sound, not leaking and if a Certificate of
Y 9
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5insp.doc•rev.7/26/201 a Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 18
` Commonwealth of Massachusetts
-� Title 5 Official Inspection Form
- Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
33Appleby Road -- — -- ---
Property Address —
Lejeune
Owner information is Owner's Name ---- — -- .--- - — .— -—
required for every Salem _ — _— — — __ MA _ 01970 _ September 4, 2020
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
2) System Conditionally Passes (cont.):
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
Dpass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
3) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
a. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
t5insp.dec•rev.M6/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System.Page 3 of 18
Commonwealth of Massachusetts
►121P Title 5 official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
uP 33 Appleby RcRoad
Property Address
Owner
Lejeune__
-----_.-- - -- -- ---- --
information is Owner's Name
required for every Salem MA_ _01970 _ September 4, 2020
page. City/Town State Zip Code Date of Inspection -
C. Inspection Summary (cont.)
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
b. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
Dsafety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well".
Method used to determine distance:
This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
c. Other:
(j 4) System Failure Criteria Applicable to All Systems:
You must indicate"Yes" or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
t5insp.doc-rev.712612018 Title 6 Official Inspection Form:Subsurface Sewage Disposal System-Page 4 of 18
Commonwealth of Massachusetts
I Title 5 Official Inspection Form
JA Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
33 Appleby Road_
Property Address —— — — —
Lejeune_
Owner Owner's Name — — -- — — — —
information is
required for every Salem _ _ MA 01970 _ September 4, 2020
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
4) System Failure Criteria Applicable to All Systems: (cont.)
Yes No
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than %day flow
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
( ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply
well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered. A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd-
10,000 gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CM 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
5) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes" or"no" to each of the-following, in addition to the
questions in Section C.4.
!, Yes No
V _ � .
❑ El the system is within400`feet of a surface drinking water supply
❑ ❑ the system4 within 200 feet of a tributary..(o a surface drinking water supply
❑ ❑ .th(system is located in a nitrogen sensitive area( nterim Wellhead Protection
11
- Area—IWPA) or a mapped Zone II of a public water supply well
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Fonn:Subsurface Sewage Disposal System•Page 5 of 18
Commonwealth of Massachusetts
f j Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
�v 33 Appleby Road
Property Address —
Le eune
Owner —.— — -- --- — —
information is Owner's Name
required for every Salem_ _ _ — MA 01970 _ _September 4, 2020 _
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
If you have answered "yes" to any question in Section C.5 the system is considered a significant
threat, or answered "yes"to any question in Section CA above the large system has failed. The
owner or operator of any large system considered a significant threat under Section C.5 or failed
under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner
should contact the appropriate regional office of the Department.
6. You must indicate "yes" or"no"for each of the following for all inspections:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system o tisJned and examined? (If they were not
available note as N/A) F,-e-vio.F Zr rna, ,161 k
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS)on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
u/ 33 Appleby Road
Property Address — — — — — - -
Lejeune
Owner Owner's Name ---- — _— ----—--- - -- �—
information is
required for every Salem — — _ _ _MA_ 01970 __ September 4, 2020
page. City/Town State Zip Code Date of Inspection
D. System Information
1. Residential Flow Conditions:
Number of bedrooms (design): 3 --- Number of bedrooms (actual): 3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x*of bedrooms): 330�
Description:
Town and owner.
Number of current residents: 2
Does residence have a garbage grinder? ❑ Yes ® No
Does residence have a water treatment unit? ❑ Yes ® No
If yes, discharges to: -- --- -
Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No
information in this report.)
Laundry system inspected? ❑ Yes ® No
Seasonaluse? ❑ Yes ® No
Water meter readings, if available (last 2 years usage (gpd)): —
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: currentDate
t5in5p.doo•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18
Commonwealth of Massachusetts
` - Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
a 33 Appleby Road
Property Address —— —— --- — ---- ——
Lejeune _
Owner Owner's Name—
——— — — — --— —— --—
information is
required for every Salem — — _ _ _ — MA 01970 September 4, 2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
2. Commercial/Industrial Flow Conditions:
Type of Establishment: ----- f/
Design flow(based on 31'0,CMR 15.203): Gallons per day((g
Basis of design flow(seats/persons/sq.ft., etc.): -- —
Grease trap present? ❑ Yes ❑ No
Water treatment unit present? ❑ Yes M No
If yes, discharges to: — -—
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the.Title 5 system? ❑ Yes ❑ No
Water meter readings, if available: --
Last date of occupancy/use: Date
Other(describe below):
3. Pumping Records:
t� Source of information: Last pumped 2 + yrs ado
J
/ Was system pumped as part of the inspection? ® Yes ❑ No
_
If yes, volume pumped: 1000 gallons _gallons
How was quantity pumped determined? by measurements
Reason for pumping: owners request -
t5insp.doe•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18
Commonwealth of Massachusetts
- l Title 5 Official Inspection Form
l� f b Susurace Sewage Disposal System Form -Not for Voluntary ry Assessments
33 Appleby Road
Property Address — -- -- —Owner —
Lejeune
--- -- ..--- - — _ .
information is
Owner's Name — —
required for every Salem_ _ _ _ MA 01970 September 4, Z92o
page. City/Town State Zip Code Date of Inspection — —
D. System Information (cont.)
4. Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract(to be obtained from system owner) and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
Approximate age of all components, date installed (if known) and source of information:
System is from in the 1960's..
Were sewage odors detected when arriving at the site? ❑ Yes ® No
5. Building Sewer(locate on site plan):
_
Depth below grade: 38"feet
Material of construction:
®cast iron ❑ 40 PVC ❑ other(explain):
Distance from private water supply well or suction line: feet �.
Comments (on condition of joints, venting, evidence of leakage, etc.):
Main line and joints are in good condition, no signs of any problems.
t5insp.doo•rev.712 612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
is Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
V 33 Appleby Road
Property Address -- — --Owner -
Lejeune
— ---— ---- -- — _ — _ ---- ---
information is
Owner's!Jame
required for every Salem _ — _ MA _01970 _ September 4, 2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
6. Septic Tank(locate on site plan):
30" 4J C'�InY�v .f r"L;G�iW �rc A
L, Depth below grade: feet -
// Material of construction:
® concrete El metal ❑ fiberglass ❑ polyethylene ❑other(explain)
1000 gallon precast concrete.
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions:
5' deep x 6 1/2' round
-- —
Sludge depth: 4" -
Distance from top of sludge to bottom of outlet tee or baffle 29" - -
Scum thickness 1 -- -
Distance from top of scum to top of outlet tee or baffle 6" -- --- - ----
Distance from bottom of scum to bottom of outlet tee or baffle 14" _
How were dimensions determined? by sticks and tape measure
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
The septic tank and baffles are in good general condition. The liquid in the tank is running at its
correct working heigth.
t5insp.doc•rev.7126=16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 116
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
t; 33 Appleby Road
Property Address --Owner — ---
Lejeune
- _..- - .. -..- - --- •- -
information is Owner's Name
required for every Salem _ _ MA_ 01970 _ September 4, 2020
page. CitylTown State Zip Code Date of Inspection
D. System Information (cont.)
7. Grease Trap (locate on site plan):
Depth;i elow grade: feet
bMaterial of construction:
❑ concrete ❑TnetaI ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness --
Distance from top of scum to top of outl • or baffle
Distance from bottom of seum to bottom of outlet tee or baffle
Date of last-pumping: Date _
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
8. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan):
__.
Depth below grade: ——
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity: gallons
Design Flow: gallons per day -
t5insp.doc•rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 16
Commonwealth of Massachusetts
- , Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
•w� %
33 I_Ap p eby Road
Property Address —— -Owner —
Lejeune
_— —---------
information is
Owner's Name
required for every Salem ! _ _MA 01970 September 4, 2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
8. Tigh=r Holding Tank(cont.)
Alarm present ❑ Yes ❑ No
Alarm level: — — Alarm in working order: ❑ Yes----El No
Date of last pumping:
Comments (conditio tarm and float switches, etc.):
*Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
9. Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert Zero
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
/ The d-box is 47" below grade and is 16" by 16" square. The d-box is level and in good condition. The
d-box has speed levels. The d-box cover is built to 6" below grade. D-box looks like it possibly was
replaced during last inspection.
t5insp.doc-rev.7/26/2018 Title 5 Officiai Inspection Form:Subsurface Sewage Disposal System-Page 12 of 18
Commonwealth of Massachusetts
lr F Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
r 33 Appleby Road
— — - —.
Property Address
Owner
Lejeune _
- ----.- -- -
information is Owner's Name —
required for every Salem MA 01970 September 4, 2020
State
page. city/Town - - -- —.,
Zip Code Date of Inspection
D. System Information (cont.)
10. Pump Chamber(locate on site plan):
Pumpsin;working order: ❑ Yes ❑ No
Alarms in working ord`e`r°- ❑ Yes ❑ No"
Comments (note condition of pump-Chamber, condition of pums aad-appurtenances, etc.):
b..
*If pumps or alarms are not in working order, system is a conditional pass.
11. Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
Located by previous title v done 9/14/18.
Type:
❑ leaching pits number: -- -
❑ leaching chambers number: —
❑ leaching galleries number:
❑ leaching trenches number, length:
® leaching fields number, dimensions:
1 - 15' x25'
❑ overflow cesspool number: —
❑ innovative/alternative system
Type/name of technology: —
t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
rs 33 Appleby Road
Property Address — —--- —_ - - — —
Lejeune
Owner - _ — ------- -- — --
information is Owner's Name — - - —
required for every Salem _ _ MA _ 01970 September 4, 2020
page. City/town State Zip Code Date of Inspection
D. System Information (cont.)
11. Soil Absorption System (SAS) (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
The SAS is in good general condition with no signs of any problems.
12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number configuration
Depth —top of liq iu d-ta,inlet invert
Depth of solids layer .---"�
Depth of scum layer —- ----
Dimensions of cesspool
Materials of construction `'t -
IN,
Indication of groundwater inflow ❑--4', s ❑ No
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5insp.doc•rev.7/2 612 0 1 8 Title 5 Official Inspection Form:Subsurface sewage Disposal system•Page 14 of 18
+ Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
r� Vy 33 Appleby Road
Property Address -
Lejeune _
Owner Owner's Name - �—
information is
required for every Salem MA 01970 September 4, 2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
13. Privy (locate on site plan):
(� Materials of-construction: - -
Dimensions - — - --
Depth of solids -- - - ----- -
Comments (note condition of soil, signs of hydraulicfiiJure, level of ponding, condition of vegetation,
etc.):
•~1
t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18
l Commonwealth of Massachusetts
Title 5 Official inspection Form
:� !I
� Subsurface Sewage Disposal System Form Not for Voluntary Assessments
33 Appleby Road
Property Address — —
Lejeune
Owner
Owner's Name
information is
required for every Salem _ _ _ MA 01970 September 4, 2020 _
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
14. Sketch Of Sewage Disposal System:
Provide a view of the sewage disposal system, including ties to at least two permanent reference
landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters
the building. Check one of the boxes below:
® hand-skeh in�ie area below —
❑ drawing ttached separately
1 �
Fond 6�-
p -33 App.4L`t PIA
R
7 Oda
Q K° '%r �'r"k
e �-- D o
„�-- a/4
� I V)
t6inep.doc•rev.7/26/2018 Title 5 official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 1a
` 4IN Commonwealth of Massachusetts
lz ,p Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
t �
33 Appleby Road
Property Address - — —
Lejeune
Owner Owner's Name — - — —- _ - - -- —
information is
required for every Salem MA 01970 September 4, 2020
page. City/Town state Zip Code Date of Inspection -
D. System Information (cont.)
15. Site Exam:
® Check Slope GI-,call
® Surface water IJ,9f f
® Check cellar D fj
® Shallow wells 1J01 --
Estimated depth to high ground water: 5.5 + - - --
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
® Observed site (abutting property/observation hole within 150 feet of SAS)
® Checked with local Board of Health -explain:
Previous title v done 9/14/18
❑ Checked with local excavators, installers- (attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
The propoerty next to the SAS drops off sharply to a depth of 10' + with no signs of water. When d-
box was replaced the person doing the excavating dug below the height of the d-box and found no
sign of ground water.
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5insp.doc•rev.7/2 612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18
` Commonwealth of Massachusetts
_ Title 5 Official Inspection Form
i Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
33 Appleby Road
Property Address --- -- - - - --- - - - - ---
Lejeune
Owner Owner's Warne — — ----- — - —
information is
required for every Salem _ — _ _MA 019_70 September 4, 2020 _
page. City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
Complete all applicable sections of this form inclusive of:
® A. Inspector Information: Complete all fields in this section.
® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked
® C. Inspection Summary:
1, 2, 3, or 5 completed as appropriate
4 (Failure Criteria)and 6 (Checklist)completed
® D. System Information:
For 8: Tight/Holding Tank—Pumping contract attached
For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached
For 15: Explanation of estimated depth to high groundwater included
t5insp.doc-rev.7/2 612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 18 of 18