Loading...
115 BOSTON STREET - BUILDING JACKET J/��os �s'� CITY OF SALEM, MASSACHUSETTS BUILDING DEPARTMENT _ 120 WASHINGTON STREET,31D FLOOR TEL. (978) 745-9595 FAX(978) 740-9846 KIMBERLEY DRISCOLL MAYOR THOMAS STYIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER May 17,2011 Marietta M. Goodridge Family Trust Marrietta Goodridge—Trustee 115 Boston Street Salem Ma. 01970. Report on structural damage-incident on 5/12/11 Dear Owner, At approximately 1600 on above time and date, I was contacted by Fire Chief David Cody, reporting a truck into a building at 115 Boston street. I arrived about ten minutes later and observe red a large box truck that had impacted the front of the home,just after the center line of the building. Approximately 16-18 feet of the fieldstone and granite foundation had been pushed into the basement and approximately 20 to 25 feet. Of the first floor wall was destroyed.. The box truck was partially inside the home and resting on the damaged foundation. At this point, ,with Salem fire, I accessed the basement to assess the condition of the structure. It was immediately apparent that at least three floor beams, that were supported by the front sill and foundation had been left unsupported. It was also apparent that the left front corner post , connecting the sill to the second floor support, had been dislodged from it's bearing point. At this time , The City Electrical Inspector arrived and determined that the main services could remain in service but that the individual circuits needed to be traced and repaired by a qualified Electrician. Shortly after this, the gas contractor, National Grid, arrived and insisted upon cutting the natural gas service at the street before attempting to shore the building or removing the truck. The Gascontractor finished the disconnect at about 1930. At that point employees of Spencer Contracting and Baystate Remodeling completed the shoring work in the basement. At approximately 2010, after looking over the condition and age of the structure, I decided to have a Structural Engineer take a look at the building before attempting removal of the truck. The structural engineer arrived and directed the workmen to install additional shoring. This work was completed at approximately 2200. Shortly thereafter the tow contractors removed the truck from the building. The board up of the front of the building commenced and was completed about 2300. Before leaving, I shut down the main breakers at the electrical panel until such time as a L ense Elec c' n could verify the safety of the wiring. +n Thomas St.Pierre/Director of Inspec nal Services/Building Commissioner QTY OF SALEM, MASSACHUSETTS BUILDING DEPARTMENT t 120 WASHINGTON STREET 3" FLOOR TSL. (978) 745-9595 FAX(978) 740-9846 KIMBERLEY DRISCOLL MAYOR THomAs ST.PIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COhSESSIONER June 6, 2011 Matthew Alphen 29 Pine Hill Road Lynnfield Ma. 01940-1125 R.E .Building at 115 Boston Street, Salem Ma. Dear Mr. Alphen, Subsequent to the emergency shoring actions taken the night of the incident May 12`x' in which a large box truck crashed into the front of 115 Boston Street, I required that a Professional Engineer evaluate the integrity of the structure, to determine the safety of the building. As it turned out, and in the light of day, additional significant damage was discovered by the Structural Engineer. If further information is needed, please contact me directly/ C -t,� UP OZ4�_� Thomas St.Pierre Director of Inspectional Services/Building Commissioner 4 Gia � av) h Plans must be filed and approved by the Inspector before a permit will be granted. No. 3- /p q City of Salem Ward Is Property Located in the 1� Historical District? Yes_ Not� p,' -/Y(/- §W3 Home Phone# Is Property Located in a P ag63 Conservation Area? Yes_ No-/— r''+ Bus.Phone# APPLICATION F PERMIT TO CONSTRUC POOL, DECKS AND SHEDS Salem, Mass., TO THE INSPECTOR OF BUILDINGS: The undersigned hereby appli'M for a permit to build according to the followin specifications: Owner's name and address d�i rnCnGi /S o l'071 S � Architect's name Mechanic's name and address Location of building, No. What is the purpose of building? Material of building? n SEEP I SC✓rmrp //9 000 I If a dwelling,for how many families? a Will the building conform to the requirements of the law? Estimated cost '�, /9010• Contractors Lic. No. Signature of applicant Signed Under the Penalty of Perjury REMARKS r) , No.6 Ward APPLICATION FOR PERMIT TO CONSTRUCT SWIMMING POOL Location PERMIT GRANTED Building Inspector 401 60Wes Suite Structures North ooPqV1® Salem,Massachusett01970-3517 CONSULTING ENGINEERS, INC P.O. Box 01971-8560 T 978.745.6817 I F 978,745.6067 x-,vw,sauctures:eo=th,com 24 June 2011 Matthew Alphen, Public Insurance Adjuster 29 Pine Hill Rd Lynnfield, MA, 01940 t I Reference: 115 Boston Street, Salem, MA , Dear Mr. Alphen: ! I have reviewed the 26 May 2011 post-loss report produced by AEGIS Engineering Services on the subject property and have observed the on-site conditions. Based upon 1 our review of the report and information we have gathered from the field, it is our opinion that without completion of permanent repairs or significant additional temporary shoring, the house is not presently in a sufficiently structurally safe condition that it could serve as a human residence without significant restrictions on the occupants. I Such occupancy restrictions would.limit the use of the house to less than 50 percent of l its total footprint and would make habitation by the owners impractical if not impossible. j + The level of temporary shoring that would be required for unrestricted occupancy would be a significant additional cost to the total project, and would be in the way of the permanent repairs, thus requiring removal and a second displacement of the residents F for the period that permanent repairs are underway. Therefore, we do not recommend that the owners re-occupy the house until permanent repairs have been completed. Respectful[ urs, IIA OF 11 .10HIM M_ g wATHNE CT Jo STRUURAL Wathne, PE, President NO.aaa2o Structures North Consulting Engineers, Inc. 9 0 a T a CITY OF SALEM, MASSACHUSETTS BUILDING DEPARTHIMENT 120 WASNGTON STREET,3m FLOOR TEL. (978) 745-9595 FAX(978) 740-9846 KIMBERLEY DRISCOLL MAYOR THomm ST.PIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER June 6, 2011 Matthew Alphen 29 Pine Hill Road Lynnfield Ma. 01940-1125 R.E .Building at 115 Boston Street, Salem Ma. Dear Mr. Alphen, Subsequent to the emergency shoring actions taken the night of the incident May 12`" in which a large box truck crashed into the front of 115 Boston Street, I required that a Professional Engineer evaluate the integrity of the structure, to determine the safety of the building. As it turned out, and in the light of day, additional significant damage was discovered by the Structural Engineer. If further information is needed, please contact me directly Thomas St.Pierre Director of Inspectional Services/Building Commissioner PROJECT MANUAL FOR 115 Boston Street Salem, MA First Floor Framing, and Associated Supports, and Foundation Replacement 18.August.2011 prepared by: Structures North Consulting Engineers, Inc. P.O. Box 8560 Salem, MA 01971-8560 (978) 745-6817 for: Marietta Goodridge 115 Boston Street Salem, MA 01970 Drawing Index: S-1.1 1st Floor framing & foundation reference plan S-1.2 2nd Floor framing reference plan S-2 Structural details S-3 Structural details S-4 Structural details S-5 Structural details S-6 Structural details Outline Specifications 4 pages VA OF JOHN M. f� WATHHE 1R� STRUCTURAL No.344W n M. athne, P.E. MA Reg. No. 34420 Y' 115 Boston Street Structures North Salem, MA 18.August.2011 Outline Specifications for First Floor Framing Modifications, Associated Supports, and Foundation Replacement General Scope of Work 0.0 The intent of this work is to replace most of the front foundation wall, a section of the left side- wall of the foundation, re-frame the first floor and associated vertical supports in the basement, and reinforce second floor framing where the ceiling finishes of the first floor have been damaged. All repair work, with the exception of the second floor framing reinforcement is due to vehicular impact to the residential structure. Damage to the first floor ceiling finishes that is suspended from the second floor framing is a direct result of the vehicular impact, which will require complete removal and replacement of the ceiling finishes in the front left room, allowing for ready access to the specified floor reinforcement. 0.1 Prior to the removal of shoring, the work depicted in sheets S-1 through S-6 must be completed. The Structural Engineer shall verify completion of this work prior to removal of shoring. 0.2 Shoring must continuously support all beams where column/post supports are to be removed and replaced or reinforced during the removal and replacement of the column/posts supports until new, permanent supports are in place and the concrete of new footings and grout below bearing plates have cured for at least 72 hours. 0.3 The contractor shall be solely responsible for all means and methods of construction employed on this project including all temporary bracing, support and protection of the existing structure as required to maintain safe and stable conditions. Any sequences of work or methods indicated or implied in the documents are presented only as assumptions on which the design of the permanent installations are based and are to be considered as a suggested option for review by the contractor. Contractor shall be solely responsible for maintaining the safety and stability of the structure and all adjacent structures as well as occupied spaces above the work area during construction. 0.4 Contractor shall field verify all existing conditions and dimensions and shall coordinate all dimensions. Notify the engineer of any discrepancies that would affect the installation as shown. 0.5 All work shall conform to applicable requirements of the Massachusetts State Building Code, Seventh Edition, and accepted construction practice. 0.6 Refer to sheets S-1 through S-6 for additional information and requirements. Shoring and Bracing - Requirements of Work: 1.0 Contractor shall be solely responsible for all means and methods of construction employed on this project, and for all temporary bracing, support, and protection of the existing structure. Provide and install shoring designed to support the temporary structural loads of the supported items. 1.1 Shoring shall be of any material, which is suitable for the application. Timber shoring shall be fully dried and all end grain shall be sealed to prevent absorption of water and associated swelling. Shoring shall be made stable, stiff, and snug fitting so as not to deflect under load. Pre load supported elements for snug fit only. Shoring shall deflect no more than the given span length divided by 600. 1.2 Bearing surfaces of shoring shall provide for proper transfer of loads to supporting and supported elements. 115 Boston Street Structures North Salem, MA 18.August.2011 Page 2 of 4 1.3 Adequate shoring and bracing shall precede structural alteration. 1.4 Screw-type shoring posts or line shoring shall be provided for existing work during the removal of existing bearing walls and structural members and the installation of new structural work. 1.5 Temporary shores shall be placed as close as practicable to the existing structural work being removed. 1.6 Balloon-framed exterior wall shall be temporarily supported with needle-type shoring or other approved method. 1.7 Headers shall be placed across top of shoring posts and shall be snug tight against underside of structure above. 1.8 Shoring shall bear on sleepers to prevent damage to the structure below. Cast-in-place Concrete & Concrete Masonry Unit(CMU) Construction— Requirements of Work: 2.0 Saw-cut or score &jackhammer existing slab as required to install new footings and walls. Provide slab infill as required following wall replacement and footing placement. 2.1 All cast-in-place concrete shall have a minimum compressive strength of 4,000-psi at 28 days. 2.2 Reinforcing steel for concrete construction shall be ASTM A615, Grade 60. 2.3 Maximum aggregate size shall be %". 2.4 Slump of concrete shall be 4" and water-cement ratio shall be less than 0.45. 2.5 Concrete is to be placed monolithically unless otherwise shown. 2.6 Provide all necessary accessories or concrete bricks to hold reinforcement securely in position with 3" of side and bottom clearance. 2.7 Footings shall be centered under supported members. 2.8 Grout below steel bearing plates shall be proprietary non-shrink type with a minimum compressive strength of 4,000-psi at 28 days. 2.9 NOTE "A" on plans indicates dowels drilled & epoxy-set with 6" to 8" embedment into existing wall/footing (#6 @ 12" o.c. x2'-8" long, Hilti HY150 or HY20+screen tubes). Provide (4) minimum per wall, centered on wall. Provide (2) in footing aligned with middle bottom reinforcement of new footing, or use pea-stone concrete mix & allow ends of footing to underpin existing wall at intersections. NOTE: Graphical representation of this noted is shown offset in plan as not to conflict with the stone shelf, however the wall dowels shall be centered about the wall. New Columns — Requirements of Work: 3.0 Structural steel work shall conform to "Specification for Structural Steel Buildings" (AISC ASD latest edition), or Load and Resistance Factor Design (AISC LRFD, latest edition), and Structural Welding Code - Steel (AWS D1.1-95). 3.1 New steel products shall conform to the following: Steel plates: A36 Steel pipe/tube columns: ASTM A500, Gr. B Welding electrodes: AWS E70-XX Adhesive Anchors: Hilti HY150 Lag Screws, Bolts to Wood: AISI/ASME B18.2.1 115 Boston Street Structures North Salem, MA 18.August.2011 Page 3 of 4 3.2 Adhesive anchors shall be installed after steel has been plumbed, aligned and base plates grouted solid between the underside of the plate and the top of the footing. Adhesive anchors shall be Hilti HY150 or approved equal. Follow all manufacturer's specifications and installation instructions. Use leveling nuts and dry-pack grout solid between the underside of the plate and the top of the footing after steel has been plumbed and aligned. Maintain temporary shoring until grout has cured for at least 72 hours 3.3 Shop and field welds shall be made by qualified welders and shall conform to the American Welding Society code for buildings, see specifications. All welds shall develop the full strength of materials being welded, unless otherwise noted. Field welding shall be avoided when possible. 3.4 Field cutting of structural steel or any field modifications to structural steel shall not be made without approval by engineer for each specific case. 3.5 All structural steel (reinforcing steel for footings, embedded sections of anchor bolts and underside of base plates not included) below grade & 12" above grade shall be coated with two heavy applications of coal-tar epoxy or Wet/Dry 700 solvent-free epoxy when ambient air temperature is at or above 55 degrees Fahrenheit. Work shall be done after steel has been installed yet before slab infill is placed; any and all gaps between base plate ring and column perimeter shall be filled with backer bar and a compatible caulking. Acceptable alternates include low-VOC epoxy mastic coatings with appropriate primers as required by the manufacturer. For other substitutes, submit product information for approval prior to purchasing material. 3.6 Temporary erection bracing and supports shall be provided to hold structural steel framing securely in position. Such temporary bracing and supports shall not be removed until permanent new structure is installed and completed. 3.7 Grout for beneath column bearing plate shall be proprietary non-shrink type or 4,000-psi dry- pack mortar mix. 3.8 Fabricate structural steel to proper field measurements before delivering to site. New/Existing Wood Framing - Requirements of Work: 4.0 Maintain support and bracing to existing structure during work. 4.1 Wood joists, blocking, posts and plates shall be SPF#2 or SYP, #2 or better. Shims shall be cedar. Laminated Veneer Lumber(LVL) shall be "Microlam" as manufactured by Trus-Joist Macmillan, or approved Equal - Fb=2900-psi, E=1,900,000-psi, Fc,=750-psi, Fcp.. e=2310-psi, FCp,rp 750-psi, Fv=285-psi. Pressure-treated lumber shall be kiln-dried after treatment (KDAT). 4.2 All new stud wall construction shall be 2x6 at 16" o.c. blocked at mid-height or at panel edges (panel edge location controls location). All new/reconstructed exterior walls shall be sheathed with 1/2" plywood nailed with 10d nails at 4" on-center at all panel edges and 12" on-center at infield. All new walls shall have pressure-treated KDAT double 2x6 bottom plates. 4.3 Holes or slots will likely need to be cored or cut in the floor of the front-right room to allow for the installation of the new concrete foundation wall. Provide all necessary labor and materials required to patch floor for any such holes. 4.4 No wood members shall be notched unless otherwise noted on the drawings. Notches called out on drawings must not be over-cut, and any members that are over-cut at notches shall be removed and replaced at no cost to the Owner. Existing members that are to be cut to allow for a new flush-framed condition shall be cut no more than required to allow for the installation 116 Boston Street Structures North Salem, MA 18.August.2011 Page 4 of 4 of new structure, and any members that are cut back beyond 90% of the hanger seat shall be sistered with full-length members at no cost to the Owner. 4.3 All new and existing members to be supported or re-supported by new structure shall have Simpson type LU, HU, HUS or approved hangers. Hangers must fit the full width and depth of supported members, and under no circumstances may the hangers be modified. Under no circumstances may post caps, bases or hangers be bent to fit the dimensions of the structural members; plywood and cedar shims shall be used as required to fill any dimensional discrepancy within 1'/z'. Any existing hangers that are installed improperly shall be removed and replaced with new hangers per the above requirements at no cost to the Owner. End of Outline Specifications Certificate No: 533-12 Building Permit No.:-533-12----------- Commonwealth o.: 533-12Commonwealth of Massachusetts City of Salem Building Electrical Mechanical Permits i This is to Certify that the RESIDENCE located at Dwelling Type I 115 BOST.O.N STREET in the CITY OF SALEM Address Tow rV City Name I I IS HEREBY GRANTED A PERMANENT CERTIFICATE OF OCCUPANCY OCCUPANCY PERMIT FOR(115 BOSTON STREET) 1 STYLOOR I This permit is granted in confornity with the Statutes and ordinances relating thereto, and expires ........ _----_ unlesssooner suspended orrevoked. Expiration Date --.. ---- - _._-._ __-_ .._.. ... Issued On: Tue May 14, 2013 - •-�r�� �r�� - -- . ..- - ------ ----- Goat MS®2013 Des Launers Municipal Solutions,Inc. ----- - ------ - --—. ------- ---- -- ........ -._- ------ ___- - Certificate No: 533-12 Building Permit No.: 533- Commonwealth of Massachusetts City of Salem Building Electrical Mechanical Permits i This is to Certify that the RESIDENCE located at Dwelling Type 115 BOSTON STREET in the CITY OF SALEM Address Town/City Name IS HEREBY GRANTED A PERMANENT CERTIFICATE OF i OCCUPANCY OCCUPANCY PERMIT FOR 115 BOSTON STREET (2ND.FLOOR This permit is granted in conformity with the Statutes and ordinances relating thereto, and expires ._,- unless sooner suspended or revoked. Expiration Date Issued On: Wed May 15, 2013 � ---- GeoTMS®2013 Des Lauriers Municipal Solutions,Inc ----"— --' ------ "'-----" - --- - ------ - " " C' 115 BOSTON STREET 533-12 Gis#Z&Ai, lla x COMMONWEALTH OF MASSACHUSETTS s ,ham v CITY OF SALEM Block �k�' I�„, v�w"�`'`xm1.L1� rxs�u_�z�,l� I ot` � 607-2Q2- Category RENOVATIONS PerDnt# �. �'*i53312q. *,y BUILDING PERMIT �Ptolect# ;_ 7S 2012-001327,', Est Cost *W ;I; $122,00000'.",„ Fee Charged' $859.00xr' ' Balance Due: $ oo A , s ,:' 6 PERMISSIONIS HEREBY GRANTED TO: f Const Class:aContractor: License: Expires [CrEIUseGroup d G&G Construction Inc CONSTRUCTIO SUPERVISOR-30314 Et a(.q..8� Zoning: 2 1 Owner: Marietta Goodridge �� B `� Units Gamedi• w .,„mss _R _„ ')Applicant: G&G Construction Inc Untts Lost µp• t` , , j I AT: 115 BOSTON STREET ISSUED ON: 07-Dec-2011 AMENDED ON: EXPIRES ON: 07-May-2012 TO PERFORM THE.FOLLOW.ING WORK: DEMOLITION OF SECTION OF FRONT FOUNDATION AND REBUILD NEW ADDITION PLEASE SEE PERMIT APPLICATION FOR ADDITIONAL WORK THAT IS BEING DONE jbh POST THIS CARD SO IT IS VISIBLE FROM THE STREET Gas Plumbing Building Underground: ✓ Y Underground Underground: - - Excavation: . Service: Meter: - Footings: Rough: J=Z..;;. Rough: Rough: Foundation: Final: 4xjne.n4jAA. 'nal: Final: _ Rough Frame: ►q. . •'�`���1-/ Fireplace/Chimney: !� D.P.W. Fire Health u1�3 f Insulation: Meter: Oil: ... �0`use Final: �i/ /j�•�1 Rouse N Smoke: /� ,�^ _:�/ ” ^— Water: Alarm: Treasury: P.C� 1 Assessor Sever. Sprinklers: Final: - THIS PERMIT MAY BE REVOKED BY THE CITY OF SALEM UPO OF RULES AND REGULATIONS. Signature: Fee IMPORTANT:OWNER OR CONTRIC@gQBrWJST Date Paid: Check No: Amount: UUI - 07-Dec-II 7776 $859.00 CONSTRUCTION.SEE CURRENT MOM CHAPTER 1 FOR LIST OF REQUIRED INSPECTIONS. _ - .CALL 978-619-5641 TO SCHEDULE AN INSPECTION _ . . . GcoTMS®2011 Des Lauriers Municipal Solutions,Inc. 4 • Y M1 � • e . `3 � x.-4Y >. 1 el �.�ONDITq,9 so VSQVE AD CITY OF SALEM BUILDING PERMIT — BOSTON ST LEGEND Structures North CONSULTING ENGINGG.a 1.Q OR (E) - INDICATES EXISTING STRUCTURE TB19.r86.80111 Fa1a)15.8081 I NNNJIIIImeesN815wn 0 SEE REBAR PLAN OR (N) — INDICATES NEW E FDN WALL DAMAGED WALL TO BE @ BM TYP. @ BM STRUCTURE TO REMAIN REMOVED & REPLACED 2 POCKET 1 2 POCKET DETAIL ON SHEET a SOLID BLOCK'G - INDICATES EXIST. S-3 S-2 S-3 STONE FDN NOTE 'A' @ 24" O.C. T a N - INDICATES NEW C.I.P.\ NOTE ,.B„ a a: CONCRETE FDN .d Q e ,a Q o a a TS - INDICATES NEW TUBE STEEL COL. —I DN PER DETAILS ON SHEET S-5 — — — — — — — — — 14 1 1 O ST - INDICATES NEW SONOTUBE PIER W/ "BIGFOOL" MODEL BF28 PER 1/S-6 `n I a Cn J1� oIQ Co J m a 3'-8" MIN. FTG NIS _ @I _ _ xo REPAIR OR REPLACE ALL s CI L _C' 7 " F_ I NO 1 STEMN 14" STONE SHELF ASPHALT AS REQ'D Y o vol O I of O 49) 4° INT. E~ I ml SHELF E"J �, L — — J I DAMAGED WALL TO BE REMOVED & REPLACED N U) o zJ o� J S-5 O (E) FDN WALL Ln Ln m z z TS TO REMAIN Q--) OG I O I r �CD L NOTE „A„ -� Y (E) HOUSE- 0 KEEPING PAD 1 x NOTE "B" L — J I J NOTE "A" - INDICATES PINNING TO (E) END, Ln (E) CHIMNEY TOSEE SPECS FOR REQUIREMENTS BE REMOVED I z 1 'n (N) 2x10 @ 116" O.C. (N) 2x101@ 16" O.C. (N) 2x 10 I@ 16" O.C. S-4 NOTE "B" -. INDICATES SHORT CANT'L BEYOND a 0 1 Nv COL. TO SUPPORT FLOOR JOISTS r — — r — — ADJACENT TO WALL OR BEYOND BASEMENT WINDOW OPENING (UP 02 \ TO 48") o NOTE "B" I NOTE "B" I NOTE ''B" NOTE 'B' J L (E) 24" RUBBLE STONE MASONRY e o FOUNDATION WALL (E) STAIR SHOWN d a a FOR REFERENCE z { Q W m GO Q CJ 0 U C O u REFERENCE PLAN 1st FLOOR FRAMING & FOUNDATION REFERENCE PIAN Drawing No:-0 � w' S-1 . 1 LEGEND a®® BOSTON ST ® { FALL EPAIR OR REPLACE Structures North E STUD WALL MISSING OR DAMAGED STUD WALL SIDING AS REQ'D OR (E) - INDICATES EXISTING CONSULTING »»» »oE»»»E»»» »� TO REMAIN TO BE REMOVED & REPLACED STRUCTURE TIDTILM91117 I fai&115,BOBf RF-BUILD DAMAGED ENTRY CANOPY PER OWNER'S SATISFACTION; COORDINATE WITH OWNERS PHOTOS OR (N) - INDICATES NEW AND DOCUMENTATION OF PRIOR CONSTRUCTION, STRUCTURE REVIEW IN FIELD WITH ENGINEER SIMPSONANGHEUC HRS I (N) INFILL FRAMING SHALL BE 13/4xFULL-DEPTH LVLs (N) 2x12 CONT. LEDGER, (N) 3Xx93� LVL HEADER W/ (RIP-TO-FIT) @ 16" O.C. OR USE NEAREST STANDARD SEE DETAIL 3/S-4 I (3)2x4 DN @ EA. END, 2J, 1K SIZE TO MATCH (E) & SUPPORT WITH (N) LEDGER c SIM. TO DETAIL 2/S-4 (SIM. ALL ATTIC & ROOF) o I . . . . . . . . Y (N) 4x4 P.T. DN, TRIM- o� N 66 TO T� j OUT PER OWNER'S m a SUPPORT SATISFACTION xld POST UP (N) 3�x7X LVL HEADER W/ Q N (4)2x4 DN @ EA. END, 2J, 2K, TYP. x3 @ EXTERIOR FLUSH @ THIS LOC'N, PROVIDE ? TOP-FLANGE 2 (F) FRAMING HANGERS S-6 N (ASSUMED) �/ E 3x3 @/_21" O.C. (N) 13/x7'4 LVLj@ 21 " O.C. o (N) 2x8 CANOPY RAFTERS al CL E" (E) FRAMING I @ 16" O.C. (E) INTERIOR (ASSUMED) I o (N) 4x4 P.T. DN, TRIM- BEARING WALLS mOUT PER OWNER'S m APPROXIMATE LOC'N OF (E)JI 11 Z 2 SATISFACTION D CHIMNEY TO BE REMOVE — z "RAMING S-4 I MISSING OR DAMAGED STUD WALL i I TO BE REMOVED & REPLACED U) Q, (E) STUD WALL TO REMAIN (E) FRAMING IN THIS AREA COMPLETELCONCEALED BY FINISHES AND APPEAR C (N) 2x6 CANOPY ^i w TO BE UN-DAMAGED APPROXIMATE LOC'N 0 E) o n —� CHIMNEY TO BE REMOVED CEIL'G JOISTS m II @ 16" O.C. � (N) 2x12 CONT. LEDGERS, SEE DETAIL 3/S-4 LU I LL1� o � 3 (E) STAIR DOWN TO o o i FORREFERENCE� — z V 1 Q mO m m Q p U F a w y o o v 2nd FLOOR (REFERENCE rT1v FRAMING S-1 2 REFERENCE PLAN Drawing No: S® 1 . 2 REPAIR (E) SHEATHING & SIDING AS8®®® T TO 3" Structures North REQ'D, PROVIDE (N) X" PLYWOOD I 2—BAYS OF SOLID FULL—DEPTH P.T. (KDAT) @ NEW WALL SECTIONS 2x10 P.T. KDAT BLOCK'G @ 2'-0" O.C. (RIP—TO—FIT) (N) OR (E) WALL ABOVE � RIM JOIST ®� ++701 re+niu.een. �i�mar (E) SILL, BORATE—TREAT PER ITEM SPEC & I \/ PROVIDE NON—SHRINK GROUT BELOW RE—CLAIMED (F) GRANITE VENEER BLOCKS, SET ON KOROLATH SHIMS & FILL BOTTOM ° & REAR VOIDS W/ NON—SHRINK GROUT • 14" MASONRY SHELF, VARY ELEV. TO MATCH (E) °"' (N)2x4 P.T. SILL W/ �6"0 a STONE LAYOUT OR PROVIDE BED OF NON— d ANCHORS @ 32" O.C. (N)2x10 FRAMING N SHRINK GROUT TO ADJUST ELEVATIONS ° 36"0 xZ" LG. STAINLESS STEEL PIN DRILLED & ADHESIVE- 0 FINISH GRADE VARIES, V.I.F. ; SET (OR C.I.P.) 3"f INTO CONCRETE, 3"t INTO STONE, & MATCH APPROPRIATE • ° 8—MIN. PER STONE, TWO—ROWS OF (4) PER STONE GRANITE VENEER BLOCKKSS (4" FROM TOP/BOT & SIDES, EQUALL SPACED BETW.) 0 N 10 MIN. AlSTEM RE—SET ENTRY STEPS ° o (NOT SHOWN) ON ° a OPTIONAL CONSTRUCTION JOINT, o COMPACTED GRAVEL ROUGHEN CONTACT SURFACES, REBAR MUST BE CONT. THROUGH JOINT N � (3) ROWS #5 @ ° a 16" O.C. HORIZEdi a a ° N w a ° #4 VERT. @ 32" O.C. UO • : : 03 • a o ° +1 (2) ROWS #5 @ 16" O.C. V.E.F. � d 0 m #5 FTG. DOWELS TO U� N 1 SIDE MATCH VERT. WALL z x COVER ° REINF. PROVIDE 32" LAP SPLICE o ° • d • a • %p" COMPRESSIBLE FILLER ° PATCH (E) BASEMENT SLAB AS REQ'D lCJ " ° 14 ROUGHEN CONTACTe a X ?�-- X X ~ m SURFACES d ° ° o °O'.00 Q w 10" MIN. • `24" MIN. :° •. 10" MIN. OQD U • ° ° °•. ° ° • ° a a • o PROVIDE 6—MIL. POLY VAPOR RETARDER @ SLAB d ° PATCHES (MIN.) e (4) #5 CONT. T&B EQUALLY SPACED a d a 3" SIDE COVER e� 3" BOTTOM COVER N j/\ /\//\// j1 12° BEND, TYP. o 0 2.0 TSF BEARING CAPACITY UNDISTURBED Z 7 STRUCTURAL ILS SOIL (TO BE VERIFIED BY OTHERS PRIOR �� T7�Tp 9ry�T 7�� gNDETo: TO CONSTRUCTION) ( 1 FO V 1 V DA 1 1 O SECTION Drawing No: S—L =7=-0- .N.O. S (N) OR (E) TO 3" B®®® WALL ABOVEKYT Structures North 2x10 P.T. KDAT CONSULTING ENGINEERS.INC. (E) SILL, BORATE-TREAT PER ITEM SPEC & RIM JOIST PROVIDE NON-SHRINK GROUT 13ELOW1b TTaASe817 I FMBIa)745 �804! RE-CLAIMED (E) GRANITE VENEER BLOCKS, X SET ON KOROLATH SHIMS & FILL BOTTOM & REAR VOIDS W/ NON-SHRINK GROUT ° do • MATCH WALL HOR. (EXT. FINISHGRADE) 14" MASONRY SHELF, VARY ELEV. TO MATCH (E) .a (N)2x10 FRAMING s REINF., TYP. x3 ROWS STONE LAYOUT OR PROVIDE BED OF NON- ° a SHRINK GROUT TO ADJUST ELEVATIONS (N)2x4 P.T. SILL W/ "0 rn i ° • • • FINISH GRADE VARIES, V.I.F. a a ANCHORS @ 32" O.C. Ll - & MATCHAPPROPRIATE (E) 0 _ - �s% 1-1 NON-SHRINK GROUT ° o ° GRANITE VENEER BLOCKS 4 ° 4" POCKET (3�5" JOIST BEARING) 0 32" MIN., TYP. �k p • /i �/ , �/\ ° ° VI ° • • • ° ° • •4 • • • SEE DETAIL 1/S-2 d FOR BOT OF WALL n & FTG INFO FOUNDATION SECTION w INT. BASEMENT • • " = 1'-0" U.N.O. ( ) N 0 0 0 m N ° SOLID 2x10 BLOCK'G BETW. o (N) OR (E) TO 3" JOISTS OVER BEAM O I'j) WALL ABOVE (N)2x10 FRAMING, LAP 4 • �• • (E) SILL, BORATE-TREAT PER ITEM SPEC & OVER BEARING POINT p PROVIDE NON-SHRINK GROUT BELOW (� i RE-CLAIMED (E) GRANITE VENEER BLOCKS, X SET ON KOROLATH SHIMS & FILL BOTTOM a o & REAR VOIDS W/ NON-SHRINK GROUT o m PLAN DETAIL OF WALL CORNER 14" MASONRY SHELF, VARY ELEV. TO MATCH (E) PROTECT END GRAIN & SIDES u D REINFORCING r T r �7 T STONE LAYOUT OR PROVIDE BED OF NON- W/ P.T. PLYWOOD o BAR REINFORCING SHRINK GROUT TO ADJUST ELEVATIONS a NTS FINISH GRADE VARIES, V.I.F. & MATCH APPROPRIATE (E) • (N)5Y4x9X LVL w GRANITE VENEER BLOCKS : a' 2x4 P.T. KDAT BEARING BLOCK 0 1-1 h" NON-SHRINK GROUT 4" POCKET (336" a a RE-SET ENTRY STEPS •4e ° a' 4 ° • BEAM BEARING) o (NOT SHOWN) ON m COMPACTED GRAVEL a °° SEE DETAIL 1/S-2 w FOR BOT. OF WALL c o x & FTG INFO STRUCTURAL BEAM POCKET SECTION DRTAlL3 Draping No: S-3 1„ 11'-0" U.N.O. S- 3 *NOTE: B®®® CONTRACTOR RESPONSIBLE Structures North FOR FLASHING & WATER- CONT. 2x12 P.T. CONSULTING EROIREERG ING PROOFING DETAILS KDAT LEDGER me,o<G,7 T R1a7"111 FRr&1AS.W8! �z ATTACH LEDGER TO EA. STUD W/ "�'""". ' I 2nd FLOOR Q >a (2) 6" LG. "TIMBERLOK" SCREWS SUBFLOOR LZ @ 16" O.C. (2-PER STUD, CENTER z J ABOUT WIDTH OF STUDS) cv 12 z j ti 3/4" PLYWOOD LOW MATCH a ROOF SHEATHING EXIST. ? 0 N ADD (N) LVLs W/IN THE BAY S GPNGPY TO ALLOW FOR THE INSTALLATION *DETAIL IS INFORMATIONAL. CONTRACTORZRPFIERS OF (N) SIMPSON HU7 FACE- SHALL OPEN WALL TO EXPOSE EXISTING (E) INT. MOUNT HANGERS, INSTALL HANGERS FRAMING CONDITIONS AND CONSULT `4 STUD WALL ENGINEER FOR FURTHER DIRECTION. W/ SIMPSON SD9 SCREWS (2) SIMPSON TYPE L50 FRAMING ANGLES, 'v 1-EA. SIDE OF RAFTER, OFFSET VERTICALLY TO AVOID NAILING CONFLICTS SECTION S-4 (N) OR (E) EXT. SHEATHING � s 1'-0" (N) 2x6 EXT. STUD WALL OR (E) EXT. STUD WALL w (N) 2x10 P.T. (1 OF 6) 4" LG "TIMBERLOK" 3 C.)(E) WALL ABOVE (N) 5Y4x9X LVL KDAT BLOCK'G SCREWS PER (N) BLOCK'G SECTION .� �- o BEAM OR (E) JOIST TO REMAIN S-4 2'-6" MIN. 1'-0" (E) SILL, BORATE-TREAT PER ITEM SPEC & I FOR BLOCK'G PROVIDE NON-SHRINK GROUT BELOW Y L 1 - - 7TFYP. — - - - - i 2 o (E) MASONRY FND (N)2x10 FRAMING ~ ~ o WALL TO REMAIN m (E) FRAMING OR (N) 2x8 BLOCK'G FINISH GRADE (RIP-TO-FIT) SISTERED TO (N) 2x10s o VARIES I I SIMPSON TYPE CC06 SADDLE WELDED TO COL. BELOW I I i N (N) TS COL. u I I '0 1 1 PROVIDE BASE PLATE & FTG a. a SIM. TO DETAIL i/S-5, REDUCE z SIZE TO 24"x24" PLAN DIM. a o m a f� F Q NI 12" MIN. SO THAT `c o (N) 24"x24" FTG DOES NOT STRUCTURAL 1 FTAILS OUNDATION SECTION UNDERMINE (E) WALL g No: Draping No: S 4 1„ - 1"-0" U.N.O. S-4 SOLID 2x 10 BLOCK'G BETW. 8®®® JOISTS OVER BEAM Structures North CON BYLTI NO ENO IN EERO INF (N)2x10 FRAMING, LAP OVER BEARING POINT W�8;v TMT"17 I F•161N&W wNw.m•�MnUN.mn (E)BEARING WALL ABOVE & (E) FRAMING NOT SHOWN FOR CLARITY. (E) FRAMING 3/p"x8 'x8" MAY BE LEFT IN PLACE & SISTERED W/ N /a" LAP IN ORDER TO SUPPORT WALL ABOVE BASE PLATE 6" 6" � DURING BEAM REMOVAL & REPLACEMENT a NJ I I N o X (N)2x10 FRAMING, LOCATE BASE PLATE PLAN cAS oLNOAP o CONFLICT w/ 2—ROWS OF 5" LG. "TRUSSLOK" ° SEE 2/S-5 FOR COL. SCREWS @ 12" O.C. STAGG. (6" BEAM MAY BE SPLICED @ INTERIOR CAP & BEAM INFO. OVERALL SPACING, ALT. SIDES SUPPORTS, BEAM MUST BE CONT. ° & OMIT AT COL. CAP — @ COLUMNS ADJACENT TO DO NOT COUNTERSINK) I NOTE "B" LOC'Ns ,I PROVIDE CORROSION PROTECTION I @ BASE OF COL. PER OUTLINE j TS=TS4x4x% TUBE SPECS 3.1 STEEL COL. PATCH SLAB AS REO'D BEAM ' F" & PROVIDE W.W.F. j j ELEVATION w JACK—HAMMER EXIST GRAVEL INFILL SLAB AS REO'D TO AS REO'D m C POUR (N) FTG. I x —' I w (N) 2x 10 FRAMING EACH SIDE a I OF LVL BEAMS, LAP OVER.BEARING a � (N) 5'px9� LVL POINT & PROVIDE SOLID 2x10 a .e —X—X X XIX X a a BEAM BLOCK'G BETW. JOISTS -o P-010.0° O = a o r^n IG LEVELING NUTS & NON— a 11 a 6" MIN., N+ i SHRINK GROUT II • ° SCJ w � a a � � �.. � z 8" EA. SIDE (2) %"0 HILTI HY150 ADHESIVE a f a � z � � OF BM � `o ANCHORS (6" EMBED) ° o W/ LEVELING NUTS ° ° a� 4° a EARTH a BRACE EA. SIDE W/ FORM • ° SIMPSON H25(A), ALT. SIDES o �TER ��� NEW 3'-0"x3'-0'x15" (MIN.) C.I.P. CONC FTG UNDISTURBED INORGANIC MAIAL W/ J/4 REBAR @ 6" O.C. EA. WAY, BOL SIMPSON TYPE CC06 W/ 2.0 TSF BRG. CAPACITY (3" BOT & SIDE CLEARANCE) (CONTRACTOR VERIFY) SADDLE WELDED TO I o COL. BELOW N ip m I 1 COLUMN FOOTING SECTION v o NTS s v Iv y v o Ls, n BEAM SECTION STRUCTURAL DETAILS S-5 Drawing No: Structures North CONSULTING ENGINEERS IN& W WNMNCn M,SUNNI 101 GUST,NO,018 11 TMTaGS17I FNR.1b.8T vNw�RumA.wm 4x4 P.T. POST UP (2-LOC'Ns) r POST BASE MAY BE SIMPSON PBS44A POST BASE EMBEDDEDI ROTATED 90' IN PLAN, INTO SONOTUBE PIER W/ #5 BENT CONFIGURATION SHOWN a AROUND EMBEDDED BASE SECTION, FOR CLARITY EXTEND VERT, LEG DOWN 24" EA. SIDE o a 12 MATCH FINISH GRADE EXIST. a (2) J/3 TIES @ TOP N 24VERT. LEGS SOLID BLOCK'G " o BETW. RAFTERS o I �i 1 3�" SIDE 4x 10 BEAM CLR. — — (1 OF 4) #5 VERT. E~ 3 z 2x8 CANOPY -N � ° g (N) 8"0 CONC. FILLED SONOTUBE I RAFTER w PIER, STRIP 3-DAYS AFTER POUR N ri) a d PROVIDE MOCK-UP OF END "BIGFOOT" MODEL BF28 2x6 (MIN.) CANOPY O P10ELCG CUTS, SOFFIT & FASCIA JOISTS v, FOOTING FOR OWNER'S APPROVAL PROVIDE SIMPSON TYPE p ALT: PROVIDE 28" SQUARE H .5(A) @ ALL RAFTER- FOOTING & 8" SQUARE PIER TO-BEAM CONNECTIONS W/ SIM. REINF. E SIMPSON TYPE PCIEPC POST 1 � � 2 4x4 P.T. m WOOD POST v 00000 0 0 0 00 Ia 000 ae� ° 90 ° °°o O Oo° o o O\— 8" COMPACTED GRAVEL ° In 02.0 2.0 TSF BEARING CAPACITY UNDISTURBED �/� SOIL OR COMPACTED FILL (TO BE VERIFIED i BY OTHERS PRIOR TO CONSTRUCTION) ` z o � z m 1 COLUMN BASE FOOTING DETAIL 2 BEAM SECTION v o '-G NTS _ NTS o ° Q U c w N voi O O u STRUCTURAL DETAILS Draping No: r S- 6