ENERGY REPORTS @ 48 ST PETER STREET HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 7, Salem, MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat!NA Duct NA
Sealed Attic: NA Duct Leakage to Outside: 33.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 33.00 CFM @ 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 506 Clg: 506 CFM50
Foundation Walls'R-20.0 Window U-Value: 0.300, SHGC: 0.210
Exposed Floor R-38.0 Heating'Fuel-fired air distribution, Natural gas, 96.0 AFUE.
Slab,R-10.0 Edge, R-10.0 Under Cooling Air conditioner, Electric, 16.0 SEER.
Water Heating',Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirements.
Name Marc Simon Signature
Organization Azimuth Home Energy Solutions Date!23 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 8, Salem, MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat NA Duct NA
Sealed Attic: NA Duct Leakage to 38.00 CFM C 25 Pascals
Outside:
Vaulted Ceiling R-49.0 Total Duct Leakage: 38.00 CFM C 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 829 Clg: 829 CFM50
Foundation Walls NA Window U-Value: 0.250, SHGC: 0.250
Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 96.0 AFUE.
Slab None Cooling Air conditioner, Electric, 16.0 SEER.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory require ents.
Name Marc Simon Signature
Ne)—
Organization Azimuth Home Energy Solutions Date May , 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software 04.6.3.1
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 8, Salem, MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirements.
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v14.6.3.1 Page 2 of 2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 9, Salem, MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat NA Duct NA
Sealed Attic. NA Duct Leakage to Outside: 29.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 29.00 CFM @ 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 309 Clg: 309 CFM50
Foundation Walls NA Window U-Value: 0.300, SHGC: 0.210
Exposed FloorR-38.0 Heating'Fuel-fired air distribution, Natural gas, 96.0 AFUE.
Slab None Cooling Air conditioner, Electric, 16.0 SEER.
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirements.
Name Marc Simon Signature I t
Organization Azimuth Home Energy Solutions Date 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 10, Salem, MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat NA Duct NA
Sealed Attic: NA Duct Leakage to Outside: 39.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 39.00 CFM @ 25 Pascals
Above Grade Walls'R-21.0 Infiltration: Htg: 387 Ctg: 387 CFM50
Foundation Watts NA Window'U-Value: 0.300, SHGC: 0.210
Exposed FloorR-38.0 Heating Fuel-fired air distribution, Natural gas, 96.0 AFUE.
Slab None Cooling Air conditioner, Electric, 16.0 SEER.
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gat.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirements.
Name Marc Simon Signature `
Organization Azimuth Home Energy Solutions Date 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 11 , Salem , MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat i NA Duct''NA
Sealed Attic: 'NA Duct Leakage to Outside: 33.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 33.00 CFM @ 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 244 Clg: 244 CFM25
Foundation Walls NA Window',,LI-Value: 0.300, SHGC: 0.210
Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 96.0 AFLIE.
Slab None Cooling Air conditioner, Electric, 16.0 SEER.
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory rreq/u' ents.
Name,Marc Simon Signature r`�+�- A
Organization Azimuth Home Energy Solutions Date li 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 12, Salem , MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling FlatNA Duct;NA
Sealed Attic: NA Duct Leakage to Outside: 34.00 CFM @ 25 Pascals
Vaulted Ceiling,,:NA Total Duct Leakage: 44.00 CFM @ 25 Pascals
Above Grade Watts R-21.0 Infiltration: Htg: 384 Clg: 384 CFM50
Foundation Watts.NA Window U-Value: 0.300, SHGC: 0.210
Exposed Floor'NA Heating Fuel-fired air distribution, Natural gas, 96.0 AFUE.
Slab None Cooling'Air conditioner, Electric, 16.0 SEER.
Water Heating',Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory req ents.
Name�Marc Simon Signature ,
Organization I Azimuth Home Energy Solutions Date 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 13, Salem , MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat R-50.4 Duct NA
Sealed Attic: NA Duct Leakage to Outside: 30.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 130.00 CFM @ 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 381 Clg: 381 CFM50
Foundation Walls NA Window LI-Value: 0.300, SHGC: 0.210
Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 96.0 AFLIE.
Slab!None Cooling Air conditioner, Electric, 16.0 SEER.
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requirem'Its.
Name I Marc Simon Signature'
Organization i Azimuth Home Energy Solutions Date 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2
HOME CERTIFIED TO MEET THE PROVISIONS OF THE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
This home built at
50 St. Peter St Unit 14, Salem , MA
by Iron Bar LLC
exceeds the minimum requirements for the 2012 International
Energy Conservation Code
Building Features
Ceiling Flat'i R-40.0 Duct NA
Sealed Attic: NA Duct Leakage to Outside: 35.00 CFM @ 25 Pascals
Vaulted Ceiling NA Total Duct Leakage: 35.00 CFM @ 25 Pascals
Above Grade Walls R-21.0 Infiltration: Htg: 559 Clg: 559 CFM50
i
Foundation WallsNA Window''LI-Value: 0.300, SHGC: 0.210
Exposed Floor NA Heating'Fuel-fired air distribution, Natural gas, 96.0 AFLIE.
Slab None Cooling',Air conditioner, Electric, 16.0 SEER.
Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal.
The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with
Chapter 4 based on Climate Zone 5A and with all mandatory requiLmMents.
Name Marc Simon Signature Vw��
Organization Azimuth Home Energy Solutions Date 21 May 2018
The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC").
No version of this software has been reviewed or approved by ICC or its affiliates.
REM/Rate - Residential Energy Analysis and Rating Software v15.4.2