Loading...
VERSA-LAM ®Boise Cascade Double 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP Floor Beam\FB01 , E Dry� 1 span � No cantilevers 10/12 slope June 28,2018 10:30:07 BC CALC®Design Report .�;, Build 6536 File Name: BC CALC Project Job Name: Description: Designs\FB01 Address: 21 Fairview Rd Specifier: City, State,Zip:Salem, MA 01970 Designer: Customer: Company: Code reports: ESR-1040 Misc: Moynihan Lumber Bev-KH - — 1 ... ... 13-06-00 BO 131 Total Horizontal Product Length=13-06-00 Reaction Summary(Down/Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live _ BO, 3-1/2" 1,620/0 875/0 B1, 3-1/2" 1,620/0 875/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf.Area (Ib/ft^2) L 00-00-00 13-06-00 20 10 12-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 7,859 ft-lbs 56.3% 100% 1 06-09-00 End Shear 2,095 lbs 33.2% 100% 1 01-01-00 Total Load Defl. L/325(0.481") 73.8% n/a 1 06-09-00 Live Load Defl. L/501 (0.312") 71.9% n/a 2 06-09-00 Max Defl. 0.481" 48.1% n/a 1 06-09-00 Span/Depth 16.5 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Post 3-1/2"x 3-1/2" 2,495 lbs n/a 27.2% Unspecified B1 Post 3-1/2"x 3-1/2" 2,495 lbs n/a 27.2% Unspecified Notes Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360)Live load deflection criteria. Design meets arbitrary(1")Maximum Total load deflection criteria. Calculations assume member is fully braced. BC CALC®analysis is based on IBC 2009. Design based on Dry Service Condition. ®Boise Cascade Double 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP Floor BeamT1301 __ Dry 1 span No cantilevers 10/12 slope June 28, 2018 10:30:07 BC CALC®Design Report Build 6536 File Name: BC CALC Project Job Name: Description: Designs\FB01 Address: 21 Fairview Rd Specifier: City, State,Zip:Salem, MA 01970 Designer: Customer: Company: Code reports: ESR-1040 Misc: Moynihan Lumber Bev-KH Connection Diagram Disclosure b d Completeness and accuracy of input must be verified by anyone who would rely on a output as evidence of suitability for • • • particular application.Output here based on building code-accepted design c properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with • • current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" c=5-1/2" (800)232-0788 before installation. b minimum=2-1/2"d =24" BC CALCO,BC FRAMER@,AJSTM Bolts are assumed to be Grade A307 or Grade 2 or higher. ALLJOISTO,BC RIM BOARD-,Bcl@. Member has no side loads. BOISE GLULAMTM,SIMPLE FRAMING Connectors are: 1/2 in. Staggered Through Bolt SYSTEM@),VERSA-LAM@,VERSA-RIM PLUS@,VERSA-RIM@, VERSA-STRAND@,VERSA-STUD@ are trademarks of Boise Cascade Wood Products L.L.C.