Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20_WISTERIA_ST.SALEM-_MA_-_DORMER__PERMIT_SET_Wed_Oct_6_2021_12-23-17
CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: OWNER: ARCHITECTURE : FLOW DESIGN ARCHITECTS 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978-498-4370 AERIAL VIEW GENERAL INFORMATION PERSPECTIVE VIEWPROJECT TEAM FOR ILLUSTRATION PURPOSES ONLY \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt TITLE SHEET JG MS 20146 T-100 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 20 WISTERIA ST. DOMER ADDITION MR. RAFAEL CAMPUSANO 20 WISTERIA STREET. SALEM, MA 01970 FLOW PROJECT #20146 PERMIT SET 06.30.2021 MR. RAFAEL CAMPUSANO 20 WISTERIA STREET. SALEM, MA 01970 PROJECT LOCATION THE EXISTING PROPERTY AT 20 WISTERIA ST IS A THREE STORY WOOD FRAMED STRUCTURE. THE EXISTING BUILDING IS APPROXIMATELY 30'-0" +/-TALL AND ENCOMPASSES 3,600 SQUARE FEET +/-. THE RENOVATION INCLUDES THE ADDITION OF DORMER AND SOME INTERIOR RENOVATIONS. N.T.S 1 06.30.2021 PERMIT SET ABBREVIATIONS A.C.P. ACOUSTIC CEILING PANEL A/C AIR CONDITION A.F.F. ABOVE FINISH FLOOR ALUM ALUMINUM A.B. ANCHOR BOLT &AND ANGLE APPROX. APPROXIMATELY ARCH ARCHITECTURAL A&G ASPHALT & GRAVEL BL BASE LINE B.PL BASE PLATE BEAM BEAM BPC BED PAN BLK'G BLOCKING B.S. BOTH SIDES B.W. BOTH WAYS BOT BOTTOM BRK. BRICK BLD'G BUILDING B/ BOTTOM OF - - - CPT. CARPET CLG CEILING CL CENTER LINE C.T.C. CERAMIC TILE COVE C.T. CERAMIC TILE CERM CERMAGUARD C.F. CEMENT FIBERBOARD C.L.F. CHAIN LINK FENCE CR CHAIR RAIL C.O. CLEAN OUT CLR. CLEAR(ANCE) CLSR. CLOSER CLS. CLOSET CHK COAT HOOK COL. COLUMN C.M. COCOA MAT CONC CONCRETE C.B. CONCRETE BLOCK CONC. BD. CONCRETE BOUND C.M.U. CONCRETE MASONRY UNIT CONSTR. CONSTRUCTION CONT. CONTINUOUS C.J. CONTROL JOINT C.G. CORNER GUARD CORR. CORRIDOR CTSK. COUNTERSUNK CRS. COURSE CYL. CYLINDER C/H CEILING HEIGHT DEPT DEPARTMENT DEP DEPRESSION DIAG DIAGONAL DIAMETER, ROUND DIM DIMENSION DO. DITTO DR DOOR D.L. DOCK LEVELER D.A. DOUBLE ACTING D.S. DOWNSPOUT D. DRAIN DWG. DRAWING D.W. DRYWALL EA. EACH E.F. EACH FACE E.W. EACH WAY ELEC. ELECTRIC E.W.C. ELECTRIC WATER COOLER ELEV. ELEVATOR, ELEVATION EL. ELEVATION ENCL. ENCLOSE, ENCLOSURE ENG. ENGINEER(ING) ENT ENTRANCE EQ. EQUAL EQUIP EQUIPMENT EXIST EXISTING EXP EXPANSION, EXPOSED E.B. EXPANSION BOLT E.J. EXPANSION JOINT EXTER EXTERIOR F.B. FACE BRICK F/ FACE OF - - - F. TO F. FACE TO FACE FT. FEET, FOOT F.W. FIELD WELD FIN. FINISH F.E.C. FIRE EXTINGUISHER CABINET F.H.C. FIRE HOSE CABINET FLASH'G FLASHING FLR. FLOOR FLR'G FLOORING F.D. FLOOR DRAIN FLUOR. FLUORESCENT FTG FOOTING FRT FIRE RETARDANT TREATED FDN. FOUNDATION F/H FULL HEIGHT FUS.LINK FUSIBLE LINK GA. GAGE OR GAUGE GALV GALVANIZED G.C. GENERAL CONTRACTOR GL. GLASS GB GRAB RAIL GYP. BD. GYPSUM WALLBOARD G.W.B. GYPSUM WALLBOARD HDCP HANDICAP HDWR HARDWARE H.D. HEAVY DUTY HGT. , HT. HEIGHT H.C. HOLLOW CORE H.M. HOLLOW METAL HORIZ. HORIZONTAL H.B. HOSE BIBB H.W.H. HOT WATER HEATER HUMI. HUMIGUARD CEILING IN.(") INCHES KKIP LBL. LABEL LAV. LAVATORY LG LENGTH, LONG LT'L LINTEL LVR. LOUVER L.P. LOW POINT M.H. MANHOLE MMARBLE MAS. MASONRY M.O. MASONRY OPENING MAT'L MATERIAL MECH. MECHANICAL MT'L MATERIAL MIN. MINIMUM MISC. MISCELLANEOUS MTG. MOUNTING NOM. NOMINAL N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE NO., # NUMBER NC NURSE CALL OFF. OFFICE O.C. ON CENTER OP'G OPENING OPP. OPPOSITE OZ. OUNCE O.D. OUTSIDE DIAMETER O.F. OUTSIDE FACE O.A. OVERALL O.H.D. OVERHEAD DOOR OFI OWNER FURNISHED AND INSTALLED OFCI OWNER FURNISHED CONTRACTOR INSTALLED PT. PNEUMATIC TUBE SYSTEM PTD. PAINTED PNL. PANEL P/H PARTIAL HEIGHT P.F. PARTICLE FILLED PTN. PARTITION PLAS. PLASTIC PL. PLASTICL P.LAM. PLASTIC LAMINATE PLUM. PLUMBING LB. POUND P.S.I. POUNDS / SQUARE INCH P.S.F. POUNDS / SQUARE FOOT PREF. PREFINISHED P.M. PRESSED METAL PROP. PROPERTY / PROPOSED Q.T. QUARRY TILE Q.T.C. QUARRY TILE COVE R. RADIUS / RISER REC RECEPTICLE / ELECTRICAL RTPH REF REFERENCE REINF REINFORCE(ING) REM REMOVE REQ'D REQUIRED REV. REVISION / REVERSE R.F. RIGID FRAME RD. ROAD R.D. ROOF DRAIN R.W.L. RAIN WATER LEADER RGH. ROUGH SECT SECTION S.S. SERVICE SINK S/S STAINLESS STEEL SH.V. SHEET VINYL S.W. SHOP WELD SL.DR. SLIDING DOOR S.C. SOLID CORE SPEC. SPECIFICATION SPR. SPRINKLER SQ. FT. SQUARE FEET STD. STANDARD ST'L STEEL STRUC. STRUCTURAL SUSP SUSPENDED SYMM. SYMMETRICAL TELE TELEPHONE TLB THOUSAND POUND THR'D THRESHOLD TOIL. TOILET T/ TOP OF - - - TB TOWEL BAR TRU-GLZ TRU-GLAZE T. TREAD TYP. TYPICAL UC. UNDERCUT UNF UNFINISHED U.N.O UNLESS NOTED OTHERWISE V.P. VENT PIPE VERT. VERTICAL VIN. VINYL V.I.F. VERIFY IN FIELD V.C.T. VINYL COMPOSITION TILE V.B.C. VINYL BASE COVE V.B.S. VINYL BASE STRAIGHT V.T.R. VENT THRU ROOF V.W.C. VINYL WALL COVERING WSCT WAINSCOT W.C. WATER CLOSET WT WEIGHT W.W.F. WELDED WIRE FABRIC W.G. WIRE GLASS W.M. WIRE MESH W/ WITH W/O WITHOUT WD. WOOD WB. WOOD BASE W.P. WORKING POINT W.P. WATER PROOF CODES & STANDARDS Building INTERNATIONAL BUILDING CODE 2015 WITH MA. AMENDMENTS INTERNATIONAL EXISTING BUILDING CODE (IEBC2015) WITH AMENDMENTS 780 CMR CHAPTER 34 GUIDELINES FOR DESIGN AND CONSTRUCTION OF RESIDENDIAL PROJECTS - 2015 WITH MA. AMENDMENTS 780 CMR 51 Residential Code GENERAL LEGEND 14 DEMOLITION NOTE KEY EXISTING DOOR TO BE REMOVED EXISTING PARTITION TO BE REMOVED EXISTING DOOR EXISTING PARTITION EXISTING GLAZING EXISTING WALL PROTECTION X XXX X XXX SECTION REFERENCE NUMBER SECTION REFERENCE SHEET DETAIL REFERENCE NUMBER DETAIL REFERENCE SHEET EXIT HANDRAIL/CRASHRAIL IN CORRIDOR (SEE DETAIL 9/A703). 6" CHAIR RAIL, ACROVYN PROTECTION BOARD, 6" VYNIL BASE IN ALL PATIENT ROOMS (SEE ELEVATIONS). STRUCTURAL FLOOR FILL AT SLAB. SEE STRUCTURAL DRAWINGS FOR REINFORCEMENT INFORMATION XX X NEW DOOR WITH REFERENCE NUMBER NEW PARTITION TYPE NEW GLAZING WITH REFERENCE NUMBER NEW WALL PROTECTION XX 1. ZONING DISTRICT ZONING REVIEW: SALEM, MA -RESIDENTIAL R2 DISTRICT THE EXISTING PROPERTY AT 20 WISTERIA ST IS A THREE STORY WOOD FRAMED STRUCTURE. THE EXISTING BUILDING IS APPROXIMATELY 30'-0" +/-TALL AND ENCOMPASSES 3,600 SQUARE FEET +/-. THE RENOVATION INCLUDES THE ADDITION OF DORMER AND SOME INTERIOR RENOVATIONS. 2. PROJECT DESCRIPTION 3. GENERAL REQUIREMENTS SECTION APPLICABILITY DESCRIPTION Neighborhood District - Dwelling District YES Minimum Lot Area (square feet) : 15,000 Minimum Lot Frontage (feet) : 100 Minimum Front Yard (feet) : 15 Minimum Side Yard (feet) : 10 Minimum Rear Yard (feet) : 30 Green Space: N/A Maximum Building Height (feet) : 35 Max. Lot Coverage : 35% 4. EXISTING AREA 5. PROPOSED 6. TOTAL +/-3,600 SF 0 SF +/-3,600 SF CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt SHEET LIST, NOTES AND LEGENDS JG MS 20146 T-101 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 SHEET LIST SHEET NUMBER SHEET NAME INITIAL ISSUE DATE DESCRIPTION TITLE SHEETS T-100 TITLE SHEET 06.30.2021 PERMIT SET T-101 SHEET LIST, NOTES AND LEGENDS 06.30.2021 PERMIT SET LIFE SAFETY LS-00 LIFE SAFETY PLAN 06.30.2021 PERMIT SET EXISTING ARCHITECTURAL AEX-100 EXISTING FLOOR PLAN 06.30.2021 PERMIT SET AEX-200 EXISTING ELEVATIONS 06.30.2021 PERMIT SET DEMO ARCHITECTURAL AD-100 DEMO FLOOR PLAN 06.30.2021 PERMIT SET ARCHITECTURAL A-101 PROPOSED FLOOR PLANS 06.30.2021 PERMIT SET A-103 PROPOSED ROOF PLAN 06.30.2021 PERMIT SET A-200 PROPOSED EXT. ELEVATIONS 06.30.2021 PERMIT SET A-600 DETAILS & PARTITIONS 06.30.2021 PERMIT SET FRAMING PLANS FP-900 FRAMING PLAN DECK 06.30.2021 PERMIT SET 1 06.30.2021 PERMIT SET LIFE SAFETY LEGEND PROJECT SPECIFIC NOTES 1 HOUR RATED SEPARATION PER IBC 2015 TABLE 508.2.5A EXIT LOCATION EXTERIOR EXIT DOOR LENGTH OF TRAVEL - EGRESS SD SMOKE DETECTOR & CARBON MONOXIDE COMBO SMOKE DETECTOR SD/CO HEAT DETECTOR E DN KNEE WALLKNEE WALL STORAGE SD SD/CO SD/CO BEDROOM 102 STORAGE 101 OPEN SPACE 103 W.I.C 104 TRAVEL DISTANCE 33'-0" E DN UP CL CL BUILT- IN LIN. PANTRY CL CL FRONT DECK CL SD/CO CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: INTERNATIONAL RESIDENTIAL CODE 2015 W/ MA AMMENDMENTS 780 CMR 51 RESIDENTIAL BUILDING CODE: Smoke alarms shall be the photoelectric type listed in accordance with UL 217 or UL 268. Combination smoke and carbon monoxide alarms shall be listed in accordance with UL 217 and UL 2034. (R314.1.1). Hardwired and Interconnected smoke alarms shall be required in the following locations as per International Residential Code for 1 and 2 Family Dwellings R314.3 with Massachusetts Amendments: 1. In each sleeping room 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. 4. In dwellings or dwelling units with split level and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 5. Smoke alarms shall be installed not less than 3 feet horizontally from the door opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by section R314.3 6. For each 1,000 sf of area or part thereof. 7. Near all stairs A single heat detector listed for the ambient enviroment shall be installed in: 1. Any garage attached to or under the dwelling (detached garages do not require a heat detector. 2. A new garage attached to an existing dwelling. If the existing house contains a fire detection system that is compatible with the garage heat detector, then the detector shall be interconnected to that system. Where the existing system is not compatible with the garage heat detector, the garage heat detector shall be connected to an alarm or compatible heat detector containing an alarm, located in the dwelling and within 20 ft of the nearest door to the garage from the dwelling. An alarm is not required in the garage, either integral or separate from the heat detector. R315.53 Carbon monoxide alarms in dwelling units shall be outside of each separate sleeping area within ten feet fo the bedrooms. Where a fuel burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. At least one alarm shall be installed on each story of a dwelling unit, including basements and cellars but not in crawl spaces and uninhabilatble attics. As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt LIFE SAFETY PLAN JG MS 20146 LS-00 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 LIFE SAFETY ATTIC PLAN 1/4" = 1'-0"2 LIFE SAFETY SECOND FLOOR PLAN 1 06.30.2021 PERMIT SET EXISTING WALL, VERIFY CONSTRUCTION IN FIELD PARTITION EXISTING CONDITIONS GENERAL NOTES IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR TO REVIEW EXISTING CONDITIONS OF THE BUILDING AND TO INFORM THE ARCHITECT OF ANY DISCREPANCIES IN THE DOCUMENTS. DN UP CL CL BUILT-IN LIN. PANTRY CL CL FRONT DECK CL STORAGE EX KITCHEN EX MASTER BEDROOM EX BEDROOM 1 EX DINING RROM EX LIVING ROOM EX BEDROOM 2 EX PORCH EX DN KNEE WALL KNEE WALLKNEE WALL EXISTING ATTIC SL O P E SL O P E SLOPESLOPE SLOPESLOPE SL O P E SL O P E SLOPE DECK BELOW CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt EXISTING FLOOR PLAN JG MS 20146 AEX-100 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 EXISTING SECOND FLOOR PLAN 1/4" = 1'-0"2 EXISTING ATTIC PLAN 1/4" = 1'-0"3 EXISTING ROOF PLAN 1 06.30.2021 PERMIT SET EXISTING WALL, VERIFY CONSTRUCTION IN FIELD PARTITION EXISTING CONDITIONS GENERAL NOTES IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR TO REVIEW EXISTING CONDITIONS OF THE BUILDING AND TO INFORM THE ARCHITECT OF ANY DISCREPANCIES IN THE DOCUMENTS. GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" RIDGE 30' -8 3/4" GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" RIDGE 30' -8 3/4" GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" RIDGE 30' -8 3/4" GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" RIDGE 30' -8 3/4" CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt EXISTING ELEVATIONS JG MS 20146 AEX-200 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 3/16" = 1'-0"5 EXISTING EAST ELEVATION 3/16" = 1'-0"1 EXISTING NORTH ELEVATION 3/16" = 1'-0"2 EXISTING SOUTH ELEVATION 3/16" = 1'-0"3 EXISTING WEST ELEVATION 1 06.30.2021 PERMIT SET EXISTING TO BE REMOVED ITEM TO BE REMOVED EXISTING TO REMAIN EXISTING TO BE REMOVED GENERAL NOTES: 1. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O. 2. PROVIDE BLOCKING AT ALL WALLS W/ WALL MOUNTED FIXTURES AND ACCESSORIES. TYP. 3. CONFIRM CEILING HEIGHTS IN FIELD. GENERAL DEMOLITION NOTES: 1. REMOVE AND DISPOSE EXISTING INTERIOR PARTITIONS AS INDICATED ON THE PLAN 2. REMOVE AND DISCARD EXISTING INTERIOR DOORS AND FRAMES AS INDICATED ON THE PLAN. 3. PATCH AND MATH CEILINGS AS NEEDED. CONFIRM AND COORDINATE WITH OWNER . 4. PATCH AND REPAIR EXISTING WALLS TO REMAIN AS REQUIRED. 5. PATCH AND REPAIR WALLS AND FINISHED ADJACENT TO AREAS OF DEMOLITION AS REQUIRED. 6. COORDINATE REMOVAL AND RELOCATION OF EXISTING FURNITURE WITH OWNER. 7. REMOVE AND DISCARD ANY EXISTING MILLWORK. CONFIRM AND COORDINATE WITH OWNER . 8. PROTECT ALL AREAS NOT BEING AFFECTED BY DEMOLITION. 9. REMOVE FOR REUSE & STORAGE ALL EXISTING LIGHT FIXTURES.CONFIRM AND COORDINATE WITH OWNER . 10. OWNER, GC, AND ARCHITECT TO WALK THROUGH AND MARK ALL EXISTING OUTLETS/DATA PORTS TO REMAIN. THESE OUTLETS/DATA PORTS MAY REQUIRE NEW PLATES AND/OR DEVICES. 11. GC TO PERFORM EXPLORATORY PROBES AT THICKENED WALL AREAS TO CONFIRM NO STRUCTURAL COLUMNS, DUCTS, PLUMBING, OR CHASES EXIST IN THESE CAVITIES PRIOR TO GENERAL DEMOLITION. 12. GC TO CUT BACK AND CAP ALL UNUSED WATER SUPPLY LINES BACK TO SOURCE. 13. REVIEW SPECIFICATIONS FOR ADDITIONAL DEMOLITION NOTES. DN UP CL CL BUILT-IN LIN. PANTRY CL CL FRONT DECK CL REMOVE EXISTING DOOR. COORDINATE W/ NEW WORK PLAN SL O P E SL O P E SLOPESLOPE SLOPESLOPE SL O P E SL O P E SLOPE DECK BELOW REMOVE EXISTING ROOF PORTION. COORDINATE W/ NEW WORK PLAN CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt DEMO FLOOR PLAN JG MS 20146 AD-100 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 DEMO SECOND FLOOR PLAN 1/4" = 1'-0"2 DEMO ROOF FLOOR PLAN 1 06.30.2021 PERMIT SET NEW WALL EXISTING & NEW WALLS EXISTING TO REMAIN GENERAL CONTRACTOR NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD. 2. CONTRACTOR SHALL ADHERE TO ALL APPLICABLE CODES AND REGULATIONS. 3. CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERRORS OR DEVIATIONS PRIOR TO CONTINUING WORK. 4. CONTRACTOR SHALL COORDINATE WITH EACH SUB- CONTRACTOR AND ENSURE TO MEET ALL CODE AND SAFETY REQUIREMENTS. GENERAL NOTES: 1. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O. 2. PROVIDE BLOCKING AT ALL WALLS W/ WALL MOUNTED FIXTURES AND ACCESSORIES. TYP. 3. CONFIRM CEILING HEIGHTS IN FIELD. DN UP CL CL BUILT-IN LIN. PANTRY CL CL FRONT DECK CL DN KNEE WALLKNEE WALL STORAGE STORAGE 101 BEDROOM 102 OPEN SPACE 103 W.I.C 104 A A A A A A 10 2 10 1 10 4 A 1' - 11"1' - 11"3' - 10" 5' - 10" EQEQ 1' - 8 " 1' - 8 " 10 4 10 5 103 EQEQEQ 4' - 8 " BATH 105 10' - 10"7' - 10" 6' - 2 " 5' - 5 " P1 P2P2 P2 P2 P1 P2 B 3' - 1 1 / 4 " 7' - 0 " A 1 2 3 11' - 4"12' - 9" 8' - 2 3 / 4 " 9' - 3" P1 NEW PARTITION WALL TO UNDERSIDE OF DECK FIRE RATING UL NUMBER TESTING CODES STC: NA USG: NANANA 1/2" GWB, BOTH SIDES 3" SOUND ATTENUATION BLANKET 2 X 4 WOOD STUDS AT 16" O.C. FS1 FIRE SEPARATION 1 HOUR RATED WALL FIRE RATING UL NUMBER TESTING CODES 1 HOUR STC: 49 USG: 87.0717 * EXTEND WOOD STUDS AND PARTITION TO UNDERSIDE OF DECK 1/2" TYPE X GWB, BOTH SIDES * PROVIDE FIRESAFING MATERIAL AT PARTITION AND CEILING TRANSITION 4 3/4" * EXTEND WOOD STUD AND PARTITION TO UNDERSIDE OF DECK U465 6 3/4" 3" SOUND ATTENUATION BLANKET 2 X 6 WOOD STUDS AT 16" O.C. FIRE RATING UL NUMBER TESTING CODES * EXTEND WOOD STUDS AND PARTITION TO UNDERSIDE OF DECK 1/2" TYPE X GWB, BOTH SIDES 6 5/8" 3" SOUND ATTENUATION BLANKET 2 X 6 WOOD STUDS AT 16" O.C. P2 WALL TO UNDERSIDE OF DECK STC: NA USG: NANANA NEW PARTITION CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt PROPOSED FLOOR PLANS JG MS 20146 A-101 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 PROPOSED SECOND FLOOR PLAN 1/4" = 1'-0"2 PROPOSED ATTIC PLAN 1 06.30.2021 PERMIT SET GENERAL CONTRACTOR NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD. 2. CONTRACTOR SHALL ADHERE TO ALL APPLICABLE CODES AND REGULATIONS. 3. CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERRORS OR DEVIATIONS PRIOR TO CONTINUING WORK. 4. CONTRACTOR SHALL COORDINATE WITH EACH SUB- CONTRACTOR AND ENSURE TO MEET ALL CODE AND SAFETY REQUIREMENTS. NEW WALL EXISTING & NEW WALLS EXISTING TO REMAIN RIDGE VENT DETAIL NTS N.T.S. NEW VINYL CLAD ALUM SIDING W/ 15# BUILDING PAPER OVER 1" POLYSTYRENE INSULATION BOARD ON 3/4" EXTERIOR GRADE PLYWOOD SHEATHING ON 2"x4" STUDS @ 16" O.C. W/ 5/8" GYP. BD. ON INTERIOR & R-21 BATT INSULATION BETWEEN STUDS 8'-10" ROOF EAVE DETAILS -H- TO P O F T O P P L A T E SPLAY (TYP.) ALUM. CONTINOUS SOFFIT VENT ON 2x3 WD NAILER NEW ALUM. GUTTER & LEADER 2x12 ROOF RAFTERS @ 16" O.C. 2 12" 7' - 2 " A . F . F . A I R F L O W 7/8" FELT PAPER SHINGLE RIDGE CAP EXHAUST V-600 COR-A-VENT RAFTER 2"x12" @ 16" o.c. CAP FLASHING 4" MIN. METAL ROOF SHINGLES CONTINUOUS HOLD DOWN STRIP C SHINGLES TO METAL 8" MIN.SHINGLES CLINCH STRIP ROOF EDGE NAILS SHINGLES CONTINUOUS HOLD DOWN STRIP D SHINGLES TO EPDM CAP FLASHING 6" MIN. 7 GENERIC DRIP EDGE Scale:N.T.S 72" ICE & WATER SHIELD EACH SIDE WOOD DECK TEND AT LEAST 12" EACH STRIP TO EX- BEYOND CENTER OF VALLEY 6" MIN. UNDERLAY- MENT EXTRA NAIL IN END OF STRIP 8 CLOSED VALLEY Scale:N.T.S 6 " M I N. 6 " M I N . BERRIDGE CEE-LOCK PANEL CEE-LOCK CLIP 20" O.C. W/ 2 CLIPSAT EAVE OR CONTINUOUS CEE-RIB W/ 2 FASTENERS36" O.C. PATENTED OPTIONAL VINYL WEATHERSEAL U.S. PATENT NO. 4,641,475 CONTINUOUS CEE RIB OR CEE CLIP J-CLIP - BUTT END JOINTS (NOT RECOMMENDED IN HEAVY SNOW AREAS) FASTENERS, 20" O.C. MAX EAVE FLASHING, 4" END LAPS WITH CONTINUOUS CAULK AT LAPS 30# FELT UNDERLAYMENT FIELD NOTCH PANEL SEAM SOLID SHEATHING PANLE AS EMBLS Y 3/4"1/2" 1 AS ROOF PANELS ARE INSTALLED, NOTCH PANEL SEAM AT EAVE. 2 THIS DETAIL NOT RECOMMENDED FOR AREAS WITH HEAVY SNOW LOADS, SEE DETAIL CL-11. 3 IF SOLID SHEATHING (BY OTHERS) IS USED, SHEATHING MUST BE MINIMUM 5/8" T&G OSB OR EQUIVALENT IN STRENGTH FOR HOLDING POWER OF FASTENERS. 16 1/2" 1 3/8" 1 1/16" 1/2" VINYL WEATHERSEAL PATENTED OPTIONAL 4,641,475 U.S. PATENT NO. CEE-LOCK PANEL CEE RIB OR CONTINUOUS CEE CLIP EAVE FLASHING CONTINUOUS CEE RIB OR CEE CLIP SECTION 1 A-300 PANEL OVERVIEW Scale:N.T.S SEAM SECTION 2 A-300 EAVE DETAIL W/ J-CLIPSOLID SUBSTRATE EAVE DETAIL W/ J-CLIP Scale:N.T.S 1/2" 1/8" F J-CLIP F 3" MIN. 1/2" 4 ALL FELT UNDERLAYMENT, CAULKING, AND FASTENERS, ARE ITEMS TO BE FURNISHED AND INSTALLED BY THE ROOFING INSTALLER AT THE DISCRETION OF THE ARCHITECT. F= FINISH SIDE CEE-LOCK PANEL NOTE: PLACE A SMALL AMOUNT OF CAULK AT J-CLIP FASTENER LOCATION. THROUGH CAULK. DRIVE FASTENER THEN CAULK FASTENER HEAD. 1 3 / 8 " 3/ 4 " 1 1 / 2 " 1 7 / 1 6 " 1 1 / 2 " ICE & WATER SHIELD OF FLASHING A OF FLASHING SECTION A-A CROSS SECTION 4 VALLEY FLASHING Scale:N.T.S A VALLEY FLASHING 3 CEE-RIB EXPANSION JOINT Scale:N.T.S HIGH RIBS OF PURLIN OR METAL DECK DETAILS BASED ON "BERRIDGE" ROOFING SYSTEM NOTE:STANDING SEAM METAL ROOFING SUPPORT CLIP SUPPORT CLIP 1 1/2" FASTENERS ATTACH THROUGH SUPPORT CLIPS ONLY 2 " C E E R I B (2 0 "-0 " L O N G ) C E E R I B (2 0 "-0 " L O N G )7 2 " E A C H S I D E OVER ICE & WATER SHIELD EDGE APP'D MET. DRIP ALONG RAKE 2" TOP LAP STRIP 72" MIN. ICE & WATER SHIELD UNDERLAYM'T 30 LB ASPH FELT 6" METAL DRIP NAILING 9" STARTER STRIP SHINGLES INVERTED OR COURSE OF WITH FULL STRIP START FIRST COURSE START THIRD COURSE WITH FULL STRIP MINUS FIRST TAB 5 Scale:N.T.S START SECOND COURSE WITH FULL STRIP MINUS 1/2 TAB TYPICAL ROOF LAYOUT 6 CONCEALED RIDGE FLASHING Scale:N.T.S SHINGLES (VARIES) DECK WOOD FLASHING W/ ICE & WATER SHIELD 72" EACH SIDE RIDGE1" 4 " T O P L A P 5 5 / 8 " 72" MIN. SL O P E EXISTING SLOPE SLOPESLOPE SL O P E SL O P E DECK BELOW 2 : 1 2 EX I S T I N G SL O P E EXISTING SLOPE NEW DORMER ROOF, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. SL O P E 2 : 1 2 SL O P E 2 : 1 2 A 1 2 3 GENERAL NOTES: 1. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O. 2. PROVIDE BLOCKING AT ALL WALLS W/ WALL MOUNTED FIXTURES AND ACCESSORIES. TYP. 3. CONFIRM CEILING HEIGHTS IN FIELD. CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt PROPOSED ROOF PLAN JG MS 20146 A-103 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 ROOF DETAILS 1/4" = 1'-0"2 GENERAL ROOF DETAILS 1/4" = 1'-0"3 PROPOSED ROOF PLAN 1 06.30.2021 PERMIT SET GENERAL CONTRACTOR NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD. 2. CONTRACTOR SHALL ADHERE TO ALL APPLICABLE CODES AND REGULATIONS. 3. CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERRORS OR DEVIATIONS PRIOR TO CONTINUING WORK. 4. CONTRACTOR SHALL COORDINATE WITH EACH SUB- CONTRACTOR AND ENSURE TO MEET ALL CODE AND SAFETY REQUIREMENTS. NEW WALL EXISTING & NEW WALLS EXISTING TO REMAIN GENERAL NOTES: 1. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O. 2. PROVIDE BLOCKING AT ALL WALLS W/ WALL MOUNTED FIXTURES AND ACCESSORIES. TYP. 3. CONFIRM CEILING HEIGHTS IN FIELD. NEW DORMER, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. B NEW SIDING , MATCH WITH EXISTING, TYP. 12 2 12 2 GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" NEW DORMER, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. NEW SIDING , MATCH WITH EXISTING, TYP. RIDGE 30' -8 3/4" GROUND LEVEL 0' -0" SECOND LEVEL 9' -3" ATTIC 18' -6" NEW DORMER, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. A A A A A A NEW SIDING , MATCH WITH EXISTING, TYP. RIDGE 30' -8 3/4" NEW DORMER, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. NEW SIDING , MATCH WITH EXISTING, TYP. 12 2 12 2 CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt PROPOSED EXT. ELEVATIONS JG MS 20146 A-200 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 3/16" = 1'-0"1 PROPOSED EAST ELEVATION 3/16" = 1'-0"2 PROPOSED NORTH ELEVATION 3/16" = 1'-0"3 PROPOSED SOUTH ELEVATION 3/16" = 1'-0"4 PROPOSED WEST ELEVATION 1 06.30.2021 PERMIT SET GENERAL CONTRACTOR NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD. 2. CONTRACTOR SHALL ADHERE TO ALL APPLICABLE CODES AND REGULATIONS. 3. CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERRORS OR DEVIATIONS PRIOR TO CONTINUING WORK. 4. CONTRACTOR SHALL COORDINATE WITH EACH SUB- CONTRACTOR AND ENSURE TO MEET ALL CODE AND SAFETY REQUIREMENTS. HEADER TRIMMER KING STUD SILL CRIPPLE STUDS HEADER TRIMMER KING STUD COMMON STUDS SUBFLOOR OPENING DOOR ROUGH LAP DOUBLE TOP PLATE 4FT (MIN) DOUBLE TOP PLATE CRIPPLE STUDS BA REFER TO SCHEDULE. RE F E R T O S C H E D U L E . REFER TO SCHEDULE. RE F E R T O S C H E D U L E . A RE F E R T O S C H E D U L E . REFER TO DOOR SCHEDULE. BSTANDARD DOOR POCKET DOOR INTERIOR RE F E R T O S C H E D U L E . REFER TO SCHEDULE. INTERIOR MIN. CLEAR 2' - 0" MAX. SILL HEIGHT A.F.F 3' - 8" FINISHED FLOOR 5.7 SF MIN. OPENABLE AREA * Exception: 5.0 SF allowed if located at grade floor or below grade. SINGLE / DOUBLE HUNG WINDOW CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt DETAILS & PARTITIONS JG MS 20146 A-600 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 DOOR SCHEDULES NO. TYPE DOOR SIZE NOTESHEIGHT WIDTH 101 B 6' - 8" 2' - 6" 102 B 6' - 8" 2' - 8" 103 A 6' - 1" 2' - 2" 104 B 6' - 8" 2' - 6" 104A A 6' - 1" 2' - 2" 105 A 6' - 1" 2' - 6" WINDOW SCHEDULE TYPE DESCRIPTION WIDTH HEIGHT COMMENTS A DOUBLE HUNG 2' - 7" 4' - 10" COORDINATE DIMENSIONS FOR EGRESS WINDOW B DOUBLE HUNG 1' - 10" 3' - 7" 1" = 1'-0"4 TYPICAL WALL FRAMING CONSTRUCTION 1/2" = 1'-0" WINDOW LEGEND 1/2" = 1'-0" DOOR LEGEND 3/4" = 1'-0"1 EGRESS WINDOW REQUIREMENTS 1 06.30.2021 PERMIT SET EXISTING SLOPE SLOPESLOPE SL O P E SL O P E DECK BELOW EX I S T I N G SL O P E EXISTING SLOPE 2 X 1 2 R O O F R A F T E R S @ 2 4 " O . C . (3) 1.75 X 11.875 APA EWS LVL STRESS CLASSES 1.9E-2600F 2X12 ROOF RAFTERS @ 24" O.C. 2 X 1 2 R O O F R A F T E R S @ 2 4 " O . C . 2 X 1 2 R O O F R A F T E R S @ 2 4 " O . C . 2 X 1 2 R O O F R A F T E R S @ 2 4 " O . C . 2X 1 2 R O O F R A F T E R S @ 2 4 " O . C . 2X 1 2 R O O F R A F T E R S @ 2 4 " O . C . 2 FP-900 A 1 2 3 ATTIC 18' -6" NEW DORMER, WITH NEW ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF & NEW ARCHITECTURAL ROOF SHINGLES TYP. NEW. VINYL SIDING W/ 15# BUILDING PAPER OVER 1/2" POLYSTYRENE INSUL. BD ON 3/4" PLYWOOD SHEATHING ON 2"X4" STUDS @ 16" O. C. W/ 5/8" GYP BD. ON INTERIOR & R -21 BATT INSUL BETWEEN STUDS R-49 BATT INSULATION R-21 BATT INSULATION 12 2 2X12 ROOF RAFTERS @ 24" O.C. EXISTING (3) 1.75 X 11.875 APA EWS LVL STRESS CLASSES 1.9E-2600F A CONSULTANT: DRAWING TITLE: DRAWING NO.: SEAL:DRAWN BY: CHECKED BY: SCALE: PROJECT NO.: PROJECT LOCATION: REVISION: NO:DATE:DESCRIPTION: DATE: ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. © 2021 Flow Design Inc. ARCHITECT: ARCHITECTURE PLANNING INTERIOR DESIGN SALEM, MA 01970 50 GROVE ST. SUITE 226 SALEM, MA 01970 TEL: 978.498.4370 CEL: 978.818.5109 CEL: 774.317.0491 RESIDENTIAL DESIGN CONSULTANT: As indicated \\flow\Projects\Architecture\2021\21172 20 WISTERIA ST. SALEM, MA - DORMER ADDITION\A_Revit\21172 20 WISTERIA ST.SALEM, MA - DORMER FINAL OPTION PERMIT SET.rvt FRAMING PLAN DECK JG MS 20146 FP-900 20 WISTERIA ST. DOMER ADDITION 20 WISTERIA STREET. SALEM, MA 01970 MR. RAFAEL CAMPUSANO 06.30.2021 1/4" = 1'-0"1 STRUCTURAL ROOF PLAN 1/2" = 1'-0"2 DORMER SECTION 1 06.30.2021 PERMIT SET