Loading...
7 Surrey Road PLANS AND ELEVATIONSN T N - PROJECT NORTH T - TRUE NORTH 1i DETAIL NUMBER MODIFIER SHEET NUMBER SECTION / DETAIL CALL-OUT ROOM NAME ROOM NUMBER ROOM TAG DOOR NUMBER DOOR TAG WALL TYPE WALL TAG WINDOW OR CURTAINWALL TYPE WINDOW OR CURTAINWALL TAG LEVEL NAME ELEVATION MARK LEVEL ELEVATION IN FEET NORTH ARROW CENTER LINE REVISION MARK REVISION NUMBER WHERE A WALLTYPE LEADER PASSES THROUGH 2 OR MORE WALLS, ALL OF THOSE WALLS SHALL BE OF THE TYPE INDICATED. A422 1 Ref 1 Re f 1 Re f 1 Ref VIEW NUMBER MODIFIER SHEET NUMBER ELEVATION CALL-OUT Name Elevation 101 Room 101 1 A SYMBOLS DRAWING TITLE: PROJECT NUMBER:SCALE: DATE: STAMP: Jones Architecture, INC 10 Derby Square Salem, MA 01970 978.744.5200 www.jonesarch.com CONSULTANT: PROJECT: CONSULTANT: 1/8" = 1'-0" A000 COVER SHEET 2175 01/25/2022 SURREY ROAD RESIDENCE 7 SURREY ROAD SALEM, MA 01970 SCHEMATIC DESIGN - FOR SPECIAL PERMIT REVIEW 00 SHEET LIST GENERAL A000 COVER SHEET ARCHITECTURE EX101 EXISTING PLANS AND ELEVATIONS A101 FLOOR PLANS & ELEVATIONS A201 ELEVATIONS & PERSPECTIVES RWL RAIN WATER LEADER SAB SOUND ATTENUATION BOARD SC SOLID CORE SEC / SECT SECTION SHT SHEET SIM SIMILAR SOPH SIMILAR OPPOSITE HAND SPEC SPECIFICATION / SPECIFICATIONS SQ SQUARE SS / ST STL STAINLESS STEEL STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE / STRUCTURAL SUSP SUSPENDED T TREAD TBD TACKBOARD / TO BE DETERMINED TD TRENCH DRAIN TEL TELEPHONE THK THICK / THICKNESS TLT TOILET TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOR TOP OF RAIL TOS TOP OF STEEL TOW TOP OF WALL TRT TREAT / TREATED TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VER VERTICAL VIF VERIFY IN FIELD VP VENEER PLASTER VWC VINYL WALL COVERING W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WF WIDE FLANGE WH WALL HYDRANT WIN WINDOW WP WORK POINT WPR WATERPROOFING WUB WALL UTILITY BOX WWF WELDED WIRE FABRIC LAV LAVATORY LCC LEAD COATED COPPER LFMF LIGHT GAUGE METAL FRAMING LINO LINOLEUM LP LOW POINT LTG LIGHTING MAT MATERIAL MAX MAXIMUM MB MARKER BOARD MECH MECHANICAL MEMB MEMBRANE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL METAL NIC NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE NUM NUMBER o DEGREE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFOI OWNER FURNISHED OWNER INSTALLED OHD OVERHEAD DOOR OHG OVERHEAD GRILL OPH OPPOSITE HAND OPNG OPENING OPP OPPOSITE ORD OVERFLOW ROOF DRAIN PAV PAVER PC PRECAST PGL PLATE GLASS PH PARTIAL HEIGHT PL PLATE PLAM PLASTIC LAMINATE PLUM PLUMBING PM PRESSED METAL POR PORCELAIN PT PAINT / PRESSURE TREATED PTD PAINTED PTN PARTITION PVC POLYVINYL CHLORIDE QT QUARRY TILE QTY QUANTITY R RISER RA RETURN AIR RAD RADIUS RD ROOF DRAIN REG REGISTER REQ REQUIREMENT REQD REQUIRED REV REVISION / REVERSE RM ROOM RO ROUGH OPENING RS ROLLER SHADE RSL RESILIENT FLOORING RUB RUBBER ELEV ELEVATION / ELEVATOR ENC ENCLOSURE ENG ENGINEER EPOX EPOXY / EPOXY PAINT EQ / EQU EQUAL EQUIP EQUIPMENT ERD EMERGENCY ROOF DRAIN ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EXIST EXISTING EXP EXPANSION EXT EXTERIOR FACP FIRE ANNUNCIATOR PANEL FD FLOOR DRAIN FDN FOUNDATION FDVC FIRE DEPARTMENT VALVE CABINET FEC FIRE EXTINGUISHER CABINET FFT FINISH FLOOR TRANSITION FHC FIRE HOSE CABINET FIN FINISH FIXT FIXTURE FLR FLOOR FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOW FACE OF WALL FSPC FIRE STANDPIPE CABINET FT FOOT / FEET FTG FOOTING FUB FLOOR UTILITY BOX FURN FURNITURE GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GL GLASS GLAZ GLAZING GWB GYPSUM WALL BOARD GYP GYPSUM HB HOSE BIBB HC HANDICAP / HANDICAP ACCESSIBLE HDW / HW HARDWARE HGT HEIGHT HM HOLLOW METAL HOR HORIZONTAL HP HIGH POINT HTR HEATER HVAC HEATING, VENTILATION, AIR COND. ID INSIDE DIMENSION IN INCHES INCAN INCANDESCENT INCL INCLUDE / INCLUDING / INCLUDED INS INSULATION INT INTERIOR J JOINT (MASONRY) JAN JANITOR JB JUNCTION BOX JT JOINT LAM LAMINATED # NUMBER % PERCENT & AND < ANGLE @ AT [ CHANNEL ACT ACOUSTICAL CEILING TILE ADD ADDITIONAL ADJ ADJACENT AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALUM ALUMINUM APPX APPROXIMATELY AWDP ACOUSTIC WOOD PANEL AWP ACOUSTIC WALL PANEL BD BOARD BIT BITUMINOUS BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BOT BOTTOM BUR BUILT-UP ROOFING C COURSE (BRICK) CB CATCH BASIN CBD CHALKBOARD CEM CEMENT CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFMF COLD FORMED METAL FRAMING CG CORNER GUARD CI CAST IRON CIP CAST IN PLACE CJ CONTROL JOINT CL CENTER LINE CL CENTERLINE CLG CEILING CLO CLOSET CLR CLEAR/CLEARANCE CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMP COMPRESSIBLE / COMPRESSION CON CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CP CENTER POINT CPT CARPET CT CERAMIC TILE CUH CABINET UNIT HEATER DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DN DOWN DR DOOR DWG DRAWING EA EACH EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC / ELECTRICAL SITE PLAN NTS ABBREVIATIONS SURREY ROAD RESIDENCE 7 SURREY ROAD, SALEM, MA 01970 SCHEMATIC DESIGN -FOR SPECIAL PERMIT REVIEW ARCHITECT JONES ARCHITECTURE, INC. 10 DERBY SQUARE, SUITE 3N SALEM, MA 01970 TEL: 978.744.5200 No. Date Revision UP UP UP DNDN OFFICE/TV ROOM LAUNDRY STORAGE 30' - 3" 5' - 11" 24' - 3 1/2" EX101 6 EX101 EX101 EX1017 4 5 GARAGE MUD ROOM DINING LIVING ROOM BEDROOMBATH ENTRY CLO KITCHEN UP UP CLO 21' - 1" 15' - 3 1/2"9' - 11"30' - 3" 24' - 3 1/2" 4' - 0" 10' SETBACK REQ. 9' - 6 1/2" EXIST CONC WALL EXISTING HVAC UNIT 27' - 2" EX101 6 EX101 EX101 EX1017 4 5 BEDROOM BEDROOM MASTER BEDROOM BATH CLO CLO CLOCLO 24' - 3 1/2" 30' - 3" ROOF BELOW FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" 13' - 9" 23' - 7" FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" 13' - 9" 23' - 7" FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" 23' - 7" 11' - 4 1/2" FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" 13' - 9" 23' - 0" DRAWING TITLE: PROJECT NUMBER:SCALE: DATE: STAMP: Jones Architecture, INC 10 Derby Square Salem, MA 01970 978.744.5200 www.jonesarch.com CONSULTANT: PROJECT: CONSULTANT: 1/8" = 1'-0" EX101 EXISTING PLANS AND ELEVATIONS 2175 01/25/2022 SURREY ROAD RESIDENCE 7 SURREY ROAD SALEM, MA 01970 SCHEMATIC DESIGN - FOR SPECIAL PERMIT REVIEW No. Date Revision SCALE:1/8" = 1'-0"EX101 1 EXISTING BASEMENT SCALE:1/8" = 1'-0"EX101 2 EXISTING FIRST FLOOR SCALE:1/8" = 1'-0"EX101 3 EXISTING SECOND FLOOR SCALE:1/8" = 1'-0"EX101 6 EXISTING EAST ELEVATION SCALE:1/8" = 1'-0"EX101 4 EXISTING WEST ELEVATION SCALE:1/8" = 1'-0"EX101 7 EXISTING NORTH ELEVATION SCALE:1/8" = 1'-0"EX101 5 EXISTING SOUTH ELEVATION 4'0 8' 16' GRAPHIC SCALEN T N - PROJECT NORTH T - TRUE NORTH UP DN 7 SURREY ROAD9,261 S.F.0.21 ACRES 136.14' S41°25'30"W 7 9 .1 6 ' S 6 7 °1 3 '5 7 "E 110.82' N41°25'30"E 75.00' N48°34'30"W 315.62' N48°34'30"W 15.7' 40.1' 4.0' 15.3' 20.9' 15.3' 2.8' 9.7' 10.2'30.3'3.6' 1.6' 5.0' 1.6' 43.99' N66°15'32"E BULK HEAD CHIMNEY GARAGE COVERED CONC. STOOP COVERED CONC. STOOP SURREY ROAD (PUBLIC-40' WIDE) 9 SURREY ROAD N/F 9 SURREY ROAD REAL ESTATE TRUST DEED REFERENCE: BOOK 31701 PAGE 148 ASSESSOR'S ID 22-0021-0 5 SURREY ROAD N/F RYAN SURREY TRUST DEED REFERENCE: BOOK 34545 PAGE 444 ASSESSOR'S ID 22-0019-0 PICKMAN ROAD N/F CITY OF SALEM DEED REFERENCE: BOOK 6682 PAGE 62 ASSESSOR'S ID 22-0179-0 P L A N B O O K 8 5 P L A N 2 5 S O U T H E S S E X R E G . O F D E E D S 122.9 112.8 124.4 115.8 224.8 847.2 CONC. WALL CONC. WALL 296.5 SBDH (HELD) ROAD SBDH UP UP ENTRY EXISTING DECK HUTCHSLIDING DOORS NEW DECK ABOVE NEW DECK/STEPS GARAGE MUDROOM KITCHEN DINING LIVING ROOM BEDROOMBATH CLO NEW ROOF ABOVE 11' - 6" 12' - 9 1/2" 18' - 9" 15' - 3 1/2"9' - 11" 19' - 0" 24' - 3 1/2" 4' - 0" PROPOSED WORK PROPOSED WORK 10'-0" SETBACK REQ. 9' - 6 1/2" 10'-0" SETBACK REQ. 10' - 4 1/2" EXISTING PATIO EXISTING CONC WALL DECK ROOF BELOW ROOF BELOW PRIMARY BEDROOM CLOSET BATH BEDROOM BATH BEDROOM BEDROOM CLO CLO CLO 25' - 2 1/2" 22' - 1" 1' - 0" 15' - 3 1/2"40' - 2" 4' - 0" 14' - 8" EXISTING HOUSE LINE PROPOSED WORK 9' - 7" 10' - 4" 12' - 9 1/2" 11' - 6" ADDITION ABOVE ADDITION AT FIRST FLOOR 5 8 ' - 3 3 / 4 " 18' - 8" EXISTING HOUSE IS 1200 SF. ADDITION FOOTPRINT IS 100 SF TOTAL BUILDING COVERAGE = 1300SF 0R 15% OF SITE AREA 1 4 0 . 0 0 ° DRAW ING TITLE: PROJECT NUMBER:SCALE: DATE: STAMP: Jones Architecture, INC 10 Derby Square Salem, MA 01970 978.744.5200 www.jonesarch.com CONSULTANT: PROJECT: CONSULTANT: As indicated A101 FLOOR PLANS & ELEVATIONS 2175 01/25/2022 SURREY ROAD RESIDENCE 7 SURREY ROAD SALEM, MA 01970 SCHEMATIC DESIGN - FOR SPECIAL PERMIT REVIEW No.Date Revision 4'0 8'16' GRAPHIC SCALE N T N -PROJECT NORTH T -TRUE NORTH SCALE:1/8" = 1'-0"A101 2 FIRST FLOOR PLAN SCALE:1/8" = 1'-0"A101 3 SECOND FLOOR PLAN SCALE:1" = 20'-0"A101 1 PROPOSED SITE PLAN FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" 22 ' - 9 3 / 4 " 21 ' - 5 1 / 4 " PROPOSED WORK EX I S T I N G R O O F L I N E 23 ' - 6 3 / 4 " NE W A D D I T I O N 13 ' - 1 3 / 4 " GROUND CONDITION AND FOUNDATION IS EXISTING FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" ENTRY -0' -9" 11 ' - 7 " PROPOSED WORK 1' - 4 " 48 " M I N 4' - 0 " 22 ' - 9 3 / 4 " 21 ' - 5 1 / 4 " 23 ' - 6 3 / 4 " 9' - 8 " 13 ' - 1 3 / 4 " 12 ' - 1 1 " FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" EXIST Basement -7' -10" ENTRY -0' -9" 11 ' - 7 " 1' - 4 " 48" MIN 4' - 0" 12' - 11"EXISTING HOUSE 23' - 7"NEW ADDITION 13' - 1 1/2" 9' - 8" 22' - 9 1/2" PROPOSED WORK EXISTING HOUSE NEW ADDITION AT FIRST FLOOR FIRST FLOOR 0' -0" SECOND FLOOR 8' -4" GARAGE -1' -4" ENTRY -0' -9" NEW FOUNDATION 48" MIN 4' - 0" 1' - 4" 11' - 7" 12' - 11" NEW ADDITION 13' - 1 1/2" 9' - 8" 22' - 9 1/2" EXISTING HOUSE 23' - 4 1/2" NEW DECK 9' - 2" DRAWING TITLE: PROJECT NUMBER:SCALE: DATE: STAMP: Jones Architecture, INC 10 Derby Square Salem, MA 01970 978.744.5200 www.jonesarch.com CONSULTANT: PROJECT: CONSULTANT: 1/8" = 1'-0" A201 ELEVATIONS & PERSPECTIVES 2175 01/25/2022 SURREY ROAD RESIDENCE 7 SURREY ROAD SALEM, MA 01970 SCHEMATIC DESIGN - FOR SPECIAL PERMIT REVIEW No. Date Revision SCALE:1/8" = 1'-0"A201 1 EAST ELEVATION SCALE:1/8" = 1'-0"A201 2 WEST ELEVATION SCALE:1/8" = 1'-0"A201 3 NORTH ELEVATION SCALE:1/8" = 1'-0"A201 4 SOUTH ELEVATION SCALE:A201 5 NORTH PERSPECTIVE SCALE:A201 6 SOUTH PERSPECTIVE