Loading...
440 Highland Avenue - Walmart - Sign2EXISTING SIGNAGE SCHEDULENEW SIGNAGE SCHEDULETOTAL AREAQTY COLORINDIVIDUALAREA1WalmartSFWHITESIGNAGE LOCATIONFRONT SIGNAGESIZE* (Spark)1SF SFLIGHTEDLEDLED YELLOW5'-6"8'-0"298.00 298.00355.85TOTAL AREAQTY COLORINDIVIDUALAREA1PickupWalmartSF SF11WHITEWHITEWHITESIGNAGE LOCATIONFRONT SIGNAGESIZE* (Spark)1LIGHTEDLEDLEDLEDN/AYELLOW4'-3"8'-0"2'-6"2'-0" 20.50 20.50SF SF32.22 32.22N/AOutdoorTOTAL FRONT SIGNAGESF359.61Outdoor LivingTOTAL FRONT SIGNAGE11WHITEWHITEN/A 2'-0"1'-0"SF SF49.47 49.47PharmacySF299.04SF299.04SF SF8.38 8.38SF SF1WHITEN/A 1'-0" 7.85 7.85Pharmacy299.04 SF1'-3"5'-6"8'-0"28'-7 1/2"1'-6"7'-1 1/2"37'-3"INTERNALLY ILLUMINATEDTYP60°TYP2'-7 3/8"WHITE PLASTIC LETTERS32.22 SF3'-4"2'-6"9'-8"INTERNALLY ILLUMINATEDNOTE TO SIGN INSTALLER:ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES.NOTE:ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR MINIMUM OF 8" ABOVE DECK6A2.1_______20.50 SF2' - 0"10' - 3"7A2.1_______7.85 SF1'-4 1/8"1'-0"5'-10 1/8"7A2.1_______SIGNAGE GENERAL NOTES1.2.A.B.C.3.A.B.C.D.E.F.G.H.I.J.SIGNAGE FURNISHED BY WALMART AND INSTALLED BY GC.ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN IN PLACE ON THE BUILDING UNTIL THE GC SIGN COMPANY IS ONSITE. THE EXISTING SIGNAGE WILL THEN BE REMOVED, PATCH AND REPAIR WORK WILL BE COMPLETED AT SIGN LOCATIONS, AND NEW SIGNAGE WILL BE INSTALLED PER PLANS.A TEMPORARY BANNER WILL BE INSTALLED PRIOR TO REMOVAL OF EXISTING EXTERIOR SIGNAGE. BANNER WILL REMAIN IN PLACE UNTIL ALL MODIFICATIONS AND/OR REPAIRS HAVE BEEN COMPLETED AND NEW SIGNAGE IS INSTALLED.TEMPORARY BANNER WILL BE APPROXIMATELY 125 SF (5'X25').EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED, COORDINATED, AND COMPLETED DURING WEEK 6 OF THE CONSTRUCTION SCHEDULE.GENERAL CONTRACTOR RESPONSIBILITIESBY END OF FIRST WEEK OF CONSTRUCTION, REVIEW EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH SIGN ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM CONSTRUCTION MANAGER TO SUBMIT RFI IN ACCORDANCE WITH SECTION 01255. NOTE DIFFERENCES IN CONSTRUCTION, INCLUDING DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR CLARIFICATION.PROVIDE SUBSTRATE SUITABLE FOR INSTALLATION OF SIGNAGE. REFER TO SIGN DETAILS FOR LIGHTED ID/LOGO SIGNS.PROVIDE JUNCTION BOXES AND CIRCUITRY TO NEW "Walmart" and "spark" SIGNAGE. EXISTING BOXES FROM "WALMART" SIGNAGE MAY BE REUSED.PROVIDE JUNCTION BOXES AND CIRCUITRY TO TENANT SIGNAGE LOCATION SHOWN. REFER TO ELECTRICAL.INSTALL ACCESS DOORS AND FRAMES IN GYPSUM BOARD CEILINGS IF REQUIRED BY RELOCATION OF EXISTING TENANT SIGNAGE.VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE. REFER TO ELECTRICALMAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE.REMOVE ALL LIT ID/LOGO SIGNS AND UNLIT EXTERIOR STUD MOUNTED BUILDING SIGNS. UNLESS NOTED OTHERWISE.MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL CONDUIT, AND SEAL PENETRATIONS PER SPECIFICATION SECTION 07900.INSTALL SIGNAGE PER DETAILS.REF CIVIL PLANSFOR SIGN LOCATIONEXISTING LIGHT POLE2'-0"5'-0"18'-0"WHITE LETTERSFLEX FACE, COLORPMS 285C BLUEYELLOW SPARK,COLOR PMS 1235CREPLACE FACE ON EXISTING SIGNEXISTING SIGNSUPPORTSFVFVILLUMINATED SIGN INFORMATIONSIGN BACKING MATERIAL: .80 ALUMINUM3105 h14 00-A-250/2-ASTM-B209WEIGHT OF LETTERS (IN LBS):5'-6" SIGNw 70a 40l 25m 55a 40r 25t 30spark 15REF BLDG ELBO SIGNAGE1/2" ALL-THREAD CUT TO WITHIN1/4" OF NUT AND GRIND ENDSMOOTH, TYPSIGN CAN WITH.080 ALUMINUM BACKINGFULL BED OFMULTI-COMPONENT SEALANTAT PERIMETER OF CONDUITDRILL HOLE AND FEEDWHIP THROUGH PARAPETEXISTING WATERPROOFINGMEMBRANESEALANT AT PERIMETER AND ANCHORS OF REMOTE POWER SUPPLY ENCLOSURE EXISTING FRAMINGEXISTING ROOFINGSYSTEMEXISTING EXTERIOR PLYWOODSHEATHING1" OD NEOPRENE/SS BONDEDWASHER PROVIDED BY WALMARTIN BED OF CONTINUOUSMULTI-COMPONENT SEALANT BYGCFULL BED OFMULTI-COMPONENT SEALANTAT PERIMETER OF SPACER, TYPPVC SPACER TO PREVENTCOMPRESSION OF EIFS, 3/4"OUTER DIAMETER AND 5/8"INSIDE DIAMETER, TYP5/8" EXTERIOR PLYWOODSHEATHINGEXISTING PLYWOODSHEATHINGNOTE:LOCATE ALL-THREADS PER SIGNATTACHMENT TEMPLATE.EXISTING EIFSREFER TO SIGNAGE GENERALNOTES FOR ADDITIONAL REQUIREMENTSREMOTE POWER SUPPLY ENCLOSURELOW VOLTAGE WIRESEALANT AT PERIMETER AND ANCHORS OF REMOTE POWER SUPPLY ENCLOSURE3/4" LIQUID TIGHT FLEXIBLE METAL CONDUITREF FOR ROOF PENETRATION DETAILSEALANT AT LOW VOLTAGE WIRE PENETRATIONSMEMBRANE PATCH OVER FASTENER CONNECTION(2) LAYERS OF MEMBRANE UNDER NUT AND WASHERTHROUGH WALL PROTECTION TUBE. INSTALL PER MFR RECOMMENDATIONS3' TO 4' ABOVE ROOF SURFACETOP OF PARAPET12" MINPREFERRED MOUNTING HEIGHT12" MIN8" MINIF WALL CAVITY IS INACCESSIBLE USE LIBERTY ANCHOR:THROUGH WALL PROTECTION TUBE FURNISHED BY WALMART INSTALLED BY GC PER MFR RECOMMENDATIONSFULL BED OF MULTI-COMPONENT SEALANT ATPERIMETER OF CONDUITINSTALL LETTER BACKPRIOR TO INSTALLATIONINDIVIDUAL PLASTICILLUMINATED CHANNELLETTERSINSTALL LETTER FACESW/ SET SCREWS, TYPLOCATE ANCHORS ANDWIRING/CONDUIT PENETRATIONSPER SIGN ATTACHMENT TEMPLATEPROVIDED BY WALMARTSEALANT ALL AROUNDELECTRICAL TO JUNCTION BOXREMOTE POWER SUPPLY ENCLOSUREHILTI HPS 1/4" X 1 5/8" SLEEVE ANCHOR PROVIDED BY WALMART AT EACH SIGN CONNECTION POINT INSTALLED BY GCLOW VOLTAGE WIRENOTE TO SIGN INSTALLER:ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.ELECTRICAL PENETRATIONS (TYP) FIELD VERIFY EXACT LOCATIONS ALTERNATE SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONS SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONSROOF LINEJOIST BEARING ELEVATION LINEREF BLDG ELEVATIONSBO SIGNNOTE:ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR MINIMUM OF 8" ABOVE DECK5A2.1_______EXISTING FRAMINGPLASTIC NON-ILLUMINATED CHANNEL LETTERPLASTIC MOUNT FOR ALL-THREAD STUD, TYPINSTALL 1/8" DIA ALL-THREAD STUDS INTO PLASTIC MOUNTS, TYP3/8" DIA HOLE FILLED WITH ADHESIVE SEALANT, TYPMOUNTING HOLE PATTERNS FOR NON-ILLUMINATED SIGN INSTALLATION PROVIDED BY WALMART"ADHESIVE SEALANT" IS TO BE PRODUCT LN-950 BY LIQUID NAILS OR SIMILAR POLYURETHANE CONSTRUCTION ADHESIVE, MEETING ASTM D3498 AND C557 STANDARDS, EXTERIOR APPLICATION, WEATHER RESISTANT, LOW VOC, WITH A MINIMUM SHEAR STRENGTH OF 250 PSIPRIOR TO PERFORMING THIS WORK, VERIFY EXISTING SUBSTRATE MATERIAL. IF EXISTING SUBSTRATE IS CMU OR PLYWOOD (5/8" OR THICKER), SUBSTRATE REPLACEMENT IS NOT REQ'DVARIESREFER TO SIGNAGE GENERALNOTES FOR ADDITIONAL REQUIREMENTS1/4" SPACER BETWEEN FACE OF BUILDING FINISH AND CHANNEL LETTERarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyMassachusetts License No. 10506STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:PROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKPROTO:2022 SUPER BUNDLESALEM, MASSACHUSETTS01/18/22CSSLDIV110/29/2101/18/22EXTERIORSIGNAGEA2.1SALEM, MASSACHUSETTSSTORE NO.2640-233JOB NUMBER: 2021.1165DIV1450 HIGHLAND AVE 1/4" = 1'-0"15'-6" WALMART SIGN 1/4" = 1'-0"22'-6" PICKUP 1/4" = 1'-0"32'-0" OUTDOOR 1/4" = 1'-0"41'-0" PHARMACY 3/16" = 1'-0"8TEMPORARY PICKUP BANNERAT EXISTING LIGHT POLE 3/16" = 1'-0"9MULTI-TENANT SIGN 1 1/2" = 1'-0"5SIGN ATTACHMENT AT EIFS ABOVE ROOF LINE 1 1/2" = 1'-0"6SIGNAGE ATTACHMENT 1/4" = 1'-0"1A5'-6" WALMART SIGN MOUNTING DIAGRAM 1 1/2" = 1'-0"7SIGN ATTACHMENT AT EIFSAND METAL STUD WALL