BOA_410 Loring Avenue - Revised Plans (08.02.21)DNU.C.Refr.REF..DNLIFE SAFETY LEGENDPROJECT SPECIFIC NOTES1 HOUR RATED SEPARATION PER IBC 2015 TABLE 508.2.5AEXIT LOCATIONEXTERIOR EXIT DOORLENGTH OF TRAVEL -EGRESS SDHARDWIRED SMOKE DETECTOR & CARBON MONOXIDE COMBOHARDWIRED SMOKE DETECTORSD/COTEMPERED GLASSTEGRESS WINDOWEDNBATH106BEDROOM101CL109BEDROOM102CL103OPEN ROOM110SD/COSDSD/COSD50' -0'' TRAVEL DISTANCESDSD/COSD/COSDTEEECL119CL120LIVING ROOMEXISTING DECKFAMILY ROOMDINING ROOMBEDROOMCLBATHCLBEDROOMBEDROOMCLLAUNDRYEXISTING DECKCLKITCHENDNUPNOT IN SCOPEUPNEW STAIR11' -0'' TRAVEL DISTANCENEW OPENINGDNUNIT 2SD/COMIN. CLEAR2' - 0"MAX. SILL HEIGHT A.F.F3' - 8"FINISHED FLOOR5.7 SF MIN. OPENABLE AREA* Exception: 5.0 SF allowed if located at grade floor or below grade.SINGLE / DOUBLE HUNG WINDOWNOT IN SCOPEUNIT 1EXISTING ENTRANCE FOR UNIT 2 ONLY TO REMAINUPSD/CO11' -0'' TRAVEL DISTANCE1/4" = 1'-0"1LIFE SAFETY ATTIC FLOOR PLAN1/4" = 1'-0"2LIFE SAFETY SECOND FLOOR PLANCONSULTANT:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2021 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNSALEM, MA 0197050 GROVE ST. SUITE 226 SALEM, MA 01970TEL: 978.498.4370CEL: 978.818.5109CEL: 774.317.0491RESIDENTIAL DESIGNCONSULTANT:As indicated\\FLOW\Projects\Architecture\2021\21060 410 LORING AVE, SALEM - ATTICRENO\A_Revit\Archive\410 LORING AVE 3_18(Recovery).0012.rvtLIFE SAFETY PLANAAMS21060LS-00410 LORING AVENUEATTIC RENO410 LORING AVENUE, SALEM,MA 01970MARIBEL NUÑEZ & YOLDYCASTILLO03.23.20211 03.23.2021 PERMIT SET3 07.02.2021 FLOOR PLANS REVISIONS1/4" = 1'-0"4LIFE SAFETY FIRST FLOOR PLAN DNU.C.Refr.REF..DNNEW WALLEXISTING & NEW WALLSEXISTING TO REMAINGENERAL CONTRACTOR NOTES:1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD.2. CONTRACTOR SHALL ADHERE TO ALL APPLICABLE CODES AND REGULATIONS.3. CONTRACTOR SHALL INFORM ARCHITECT OF ANY ERRORS OR DEVIATIONS PRIOR TO CONTINUING WORK.4. CONTRACTOR SHALL COORDINATE WITH EACH SUB-CONTRACTOR AND ENSURE TO MEET ALL CODE AND SAFETY REQUIREMENTS.GENERAL NOTES:1. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O.2. PROVIDE BLOCKING AT ALL WALLS W/ WALL MOUNTED FIXTURES AND ACCESSORIES. TYP.3. CONFIRM CEILING HEIGHTS IN FIELD.DNBATH106BEDROOM1011' - 3"NEW CABINETS2' - 0"CL109 7' - 0"BEDROOM1022' - 0" 8' - 2 "CL10310' - 0"2' - 0"1' - 5"OPEN ROOM1103' - 6"10' - 0" 7' - 2" 3' - 3"EXISTING CHIMNEY104103109EETDEDAAEEAAA 6' - 4" 13' - 7"7' - 0"3' - 4" 2' - 6" 3' - 4"NEW OPENINGLN8' - 0"10' - 0"12' - 0"CL119VIF24' - 9"6' - 0"4' - 7"10' - 0"10' - 1"3' - 0"1' - 10"3' - 10"2A-2011191' - 6"BEDROOM115106FAMILY/OPENROOM1114' - 0"102ALIGN2' - 2 1/4"1' - 9 3/4"A1' - 9"4' - 0"2' - 0"135134CL120OPEN ROOM1072' - 6"EQEQ2' - 10"2' - 10"2' - 0"EQEQ3' - 8"3' - 8"9' - 11"LIVING ROOMEXISTING DECKFAMILY ROOMDINING ROOMBEDROOMCLBATHCLBEDROOMBEDROOMCLLAUNDRYEXISTING DECKCLKITCHENDNUPNOT IN SCOPEUPNEW STAIRPROPOSED OPENINGUNIT 21201' - 6"DNNOT IN SCOPEUNIT 1EXISTING ENTRANCE FOR UNIT 2 ONLY TO REMAINUPCONSULTANT:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOW DESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2021 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNSALEM, MA 0197050 GROVE ST. SUITE 226 SALEM, MA 01970TEL: 978.498.4370CEL: 978.818.5109CEL: 774.317.0491RESIDENTIAL DESIGNCONSULTANT:As indicated\\FLOW\Projects\Architecture\2021\21060 410 LORING AVE, SALEM - ATTICRENO\A_Revit\Archive\410 LORING AVE 3_18(Recovery).0012.rvtPROPOSED FLOORPLANSAAMS21060A-101410 LORING AVENUEATTIC RENO410 LORING AVENUE, SALEM,MA 01970MARIBEL NUÑEZ & YOLDYCASTILLO03.23.20211/4" = 1'-0"1PROPOSED ATTIC FLOOR PLAN1/4" = 1'-0"2PROPOSED SECOND FLOOR PLAN1 03.23.2021 PERMIT SET3 07.02.2021 FLOOR PLANS REVISIONS1/4" = 1'-0"3PROPOSED FIRST FLOOR PLAN