Loading...
6 OAK STREET - CERTIFICATION LETTER BARUN CORP October 29,2020 RE: CERTIFICATION LETTER Project Address: Ramos,Reynaldo Residence 6 Oak St, Salem,MA 01970 Design Criteria: Applicable Codes=MA Res.Code 9th Edition/IEBC,2015 IRC,ASCE 7-10,and 2015 NDS Risk Category=II Wind Speed=127 mph,Exposure Category C, Partially/Fully Enclosed Method Ground Snow Load=50 psf -Roof 1&2&3:2x8 @ 24"OC, Roof DL=11 psf,Roof LL/SL=39 psf(Non-PV),Roof LL/SL=22.5 psf(PV) To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was provided.All structural evaluation is based on the site inspection observations and the design criteria listed above.The evaluation is only valid when provided information is true and accurate. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, Yuri Yurianto S.E,P.E. MA jVk OF 2� s,9cy URA TO C- O YURIANTO to U STRUCTURAL -4 o No.55070 /STF- �lr' `h]lONA1-� By Yuri at 7:41:08 PM, 1012912020 Barun Corp i Design and Engineering i 610.202.4506 chrisk@barun-corp.com I www.barun-corp.com Roof 1&2&3 PV System Dead Load(PV-DL) PV module weight 2.5 psf Hardware assembly weight 0.5 psf PV-DL 3 psf Roof Dead Load(R-DL) Material Panel Area Existing Roofing Material Comp Roof 1 layers 2.5 psf Underlayment 0.5 psf Plywood Sheathing 1.5 psf Rafter Size and Spacing 2 x 8 @ 24 in.O.C. 1.56 psf Vaulted ceiling Yes 3 psf Miscellaneous 1.5 psf Total Roof Dead Load R-DLj 11 psf Reduced Roof Live Load(Lr) Expression Value Roof Live Load L. 20.0 psf Member Tributary Area At <200 sf Roof 1&2&3 Roof Pitch 9/12 or35° Trubutary Area Reduction Rl 1 Slope Roof Reduction RZ 0.775 Reduced Roof Live Load Lr=L.(Ri)(Rz) 15.5 psf Snow Load Value Ground Snow Load pg 50 Effective Roof Slope 35' Snow Importance Factor IS 1.0 Snow Exposure Factor Ce 1.0 Snow Thermal Factor Ct 1.1 Minimum Flat Roof Snow Load Pf-min 20 Flat Roof Snow Load Pf 38.5 Slope Roof Snow Load on Roof (All other surfaces) Roof Slope Factor C s roof 1.00 Ps-roof 38.50 Sloped Roof Snow Load on PV Unobstructed slip pery ppery surfaces) Roof Slope Factor C' 0.58 ps-py 22.50 Barun Corp I Design and Engineering 610.202.4506 chrisk@barun-corp.com www.barun-corp.com COMPANY PROJECT WoodWorks® SO"WAREFOR WOOD DESIGN Oct. 29, 2020 18:40 Roof 1&2&3 Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 1) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 11.00 (24.0") psf DL-PV1 Dead Partial Area No 4. 90 10.42 3.00 (24.0") psf SL-PV1 Snow Partial Area No 4. 90 10.42 22.50 (24.0") psf SL1 Snow Partial Area No 0.00 4.90 38.50 (24.0") psf SL2 Snow Partial Area No 1 10.42 10.53 38.50 (24.0") psf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) - - J3.616' 1' 10.509' Unfactored: Dead 172 159 Snow 393 241 Factored: Total 564 401 Bearing: F'theta 567 567 Capacity Joist 744 425 Support 586 586 Des ratio Joist 0.76 0. 94 Support 0. 96 0. 68 Load comb #2 #2 Length 0.50* 0.50* Min read 0.48** 0.50* Cb 1.75 1.00 Cb min 1.75 1.00 Cb support 1.25 1.25 Fcp sup 625 625 "Minimum bearing length setting used: 1/2"for end supports and 1/2"for interior supports "Minimum bearing length governed by the required width of the supporting member. Roof1&2&3 Lumber n-ply, S-P-F, No.1/No.2, W, 1-ply (1-1/2"x7-1/4") Supports: All -Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0"c/c; Total length: 13.62'; Clear span: 1.224', 11.834;Volume = 1.0 cu.ft.; Pitch: 9/12 Lateral support: top = continuous, bottom = at supports; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. F: - WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Roof 1&2&3 WoodWorksO Sizer 2019 (Update 1) Page 2 Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Desi n Shear fv = 45 Fv' = 155 psi fv/Fv' = 0.29 Bending(+) fb = 888 Fb' = 1389 psi fb/Fb' = 0. 64 Bending(-) fb = 48 Fb' = 785 psi fb/Fb' = 0.06 Live Defl 'n 0.23 = L/607 1.19 = L/120 in 0.20 Total Defl'n 0.44 = L/325 1.43 = L/100 in L 0.31 Additional Data: FACTORS: F/E (psi) CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 875 1.15 1.00 1.00 1.000 1.200 - 1.15 1.00 1.00 - 2 Fb'- 875 1.15 1.00 1.00 0.565 1.200 - 1.15 1.00 1.00 - 2 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1 .4 million 1.00 1. 00 - - - - 1.00 1.00 - 2 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S Bending(+) : LC #2 = D+S Bending(-) : LC #2 = D+S Deflection: LC #2 = D+S (live) LC #2 = D+S (total) Bearing Support 1 - LC #2 = D+S Support 2 - LC #2 = D+S D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.2 CALCULATIONS: V max = 369, V design = 328 lbs; M(+) = 973 lbs-ft; M(-) = 52 lbs-ft EI = 66.69e06 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow...) Total deflection = 1.5 dead + "live" Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Lateral stability(-) : Lu = 11.88 ' Le = 18.94 ' RB = 27.1; Lu based on full span Design Notes: 1. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2018), the National Design Specification (NDS 2018), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. FIRE RATING: Joists, wall studs, and multi-ply members are not rated for fire endurance. 7. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design.