Loading...
B-19-84 - 0032 BOW STREET - Building Permit s%a The Commonwealth of Massachusetts ` Board of Building Regulations and Standards CITE'OF t` >E Massachusetts State Building Code, 780 CMR yy SALE, ma's ..i�l uc ya"iseIVir-0TI Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Fanzily Dwelling I This Section For Official Use Only Building Permit Number: Date Applied: 60 9 E.JL C y w,�+s� � S` =�x'�� I-2.3'/g 1 Building Official(Print Name) Signature 411 Date SECTION 1:SITE INFORMATION f1.1 Property Address: 1.2 Assessors Map& Parcel Numbers 3z z,- s/ 1 l.la Is this an accepted street?yes no tMap Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: 4 Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1 1.5 Building Setbacks(ft) , Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40.§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone" Check if ves❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Ownert of Reco d Alexandra Dekalatos Name(Print) City,State,ZIP 32 Bow Street Salem, MA 01970 No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units Other ❑ Specify: Brief Description of Proposed Work':-' Z� t SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building S 3 9-,jy 1. Building Permit Fee: S Indicate how fee is determined: 2. Electrical S ❑Standard City!Town Application Fee - ❑Total Project Cost'(item 6)x multiplier x 3. Plumbing S 2. Other Fees: S 4. Mechanical (HVAC) S List: 5. Mechanical (Fire Su ression) S Total All Fees:$ Check No. Check Amount: Cash Amount: 6. Total Project Cost: S 0 paid in Full ❑Outstanding Balance Due: SECTIONS: CONSTRUCT][ON SERVICES ' 5.1 Construction Supervisor License(CSL) , License Number Expiration Date Name of CSL Holder ` List CSL Type(see below) No.and Street Type Description U Unrestricted Buildin s:u to 35,000 cu.ft:) l Mt71 .4 R Restricted 1&2 FamilyDwelling City/Town,State,�1P NI Masonry RC '.Rootin`'Covean WS Window and Siding 130S _ SF Solid Fuel Burning Appliances �7�5 I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 11. .1 \10`a�-4 G t Z� d k v t t- % SCJ 1G r iL e1rJ(� Y �-(- HIC Registration Number Expiration Date HIC Company Name or H C Registrant Name Z�O �.�11Gr�\/CrIG? S'1' Ep�KQ• SILV��'vtr� �Ctr.Gbi No.and Street �I�, • '1C.?r-� -� i?� 3N3 0 Email address Cil /town,Slzhe,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes:.:. No...........p SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. 01/09/19 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNERS OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. f Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),.will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.goyfoca Information on the Construction Supervisor License can be found at www.thass.gov/dPS 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" n/ owu into C o I a C 1800 W Ashton Blvd. ,V:/ `V"JSt11ru11cturaal Group Lehi, UT 84043 J. Matthew Walsh, SE, PE Samuel Brown,PE Senior Structural Engineering Manager Structural Engineer James.walshC@vivintsolar.com sam.brown@a vivintsolar.com January 21, 2019 Re: Structural Engineering Services Mekalatos Residence 32 Bow St, Salem, MA S-6038718; MA-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System'layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components and consists of the following: • Roof Sections (1 and 3): Dimensional lumber - 2x6 at 16" on center. Surrey photos indicate that there was free access to verify the framing size and spacing. • Roof Section 2: Dimensional lumber- 2x6 at 16" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 9.13 PSF= Dead Load (roofing/framing) 2.59 PSF= Dead Load(solar panels/mounting hardware) 11.72 PSF=Total Dead Load 20 PSF= Roof Live Load 50 PSF=Ground Snow Load (based on local requirements) Wind speed of 127 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C.Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • Unirac, Inc. Installation Manual,which can be found on the Unirac, Inc.website(www.unirac.com). 2. The solar panels are 11/z' thick and mounted 41/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. Page 1 of 2 xvi V i nt so l a r Page 2of2 3. The following mounting types shall be used. Please refer to the mounting details for the associated required penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per connection and therefore is adequate. • Unirac, Inc.: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir is 235 Ibs/inch penetration. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers'data, which are available upon request. Panel support connections should be staggered, where possible,to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 64 64 64 48 48 48 Max Uplift Load Ibs 174 141 133 293 239 224 D.Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2015 International Residential Code with Massachusetts Amendments,current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. of MA3 qc S Regards, ti : G J. MATTtEN m J. Matthew Walsh, SE, PE � N i �� y MA License No. 54057 o NO. 54057 /STER�� ass/ONAI��� 01/21/2019 GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES a. 2015INTERNATIONAL RESIDENTIAL CODE b. 2017 NATIONAL ELECTRICAL CODE C. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE SFM SYSTEM BY UNIRAC.THE MOUNTING FEET ARE TO BE SPACED AS SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO ADJACENT FRAMING THE ROOF SURFACE. MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE%e"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2X'PENETRATION INTO ROOF FRAMING. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE C. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psf TYPICAL,0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=50 psf VOLTAGE. I. WIND SPEED=127 mph f 5. SEE*E 1.0 AND*E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND 9. EXPOSURE CATEGORY=B �„ SPECIFICATIONS. yiyint.Solar 1800 ASHTON BLVD.LEHI,UT,84M 1.877.404.4129 MA LICENSE: HIC-1701148, ME-15688A,SS-002342 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: MEKALATOS RESIDENCE ¢' SYSTEM SIZE-8.680kW DC 7.600kW AC 32 Bow sT I SALEM,MA,01970 MODULE TYPE&AMOUNT-(28)Jinko Solar JKM31 OM-60SL WITH 28 SolarEdge P320 OPTIMIZERS UTILITY ACCOUNT*25732-93019 MODULE DIMENSIONS-(U/WIH)65.55'I 39.45"I 1.38" • vy. INVERTER-(1)SolarEdge Technologies SE7600H-USOOONNC2 SERVICEM S-6038718COVER REGIONAL INTERCONNECTION METHOD-SUPPLY TAP OPERATING CENTER:MA-01 DATE:1/1912019 SHEET a.=,P A DRAWN BV:DIN PVSTRING(S): 1 SLOPE-41 SYSTEM LEGEND' ® #1)14 MODULES AZIMUTH-88 PV SYSTEM SIZE: MATERIAL- ® #2)14 MODULES OMPOSITION SHINGLE NEW 8.68OkW DC I 7.600kW AC 32 BOW ST U2 SLOPE-21 EXISTING INTERIOR MAIN SERVICE PANEL TIED AZIMUTH-88 �TO UTILITY METER#069936621. MATERIAL- FRONT OF HOUSE. OMPOSITION SHINGLE NEW SMART PRODUCTION METER.LOCATED (3 SLOPE-11 P WITHIN 10 OF MSP. AZIMUTH-268 NEW PV SYSTEM AC DISCONNECT. LOCATED MATERIAL- ® WITHIN 10'OF MSP. O COMPOSITION SHINGLE I 1 NEW PV SYSTEM INVERTER:SolarEdge Terhnologie 4�SE7600H-US000NNC2(RSD EQUIPPED) 28 NEW JINKO SOLAR JKM31OM-60BL MODULES. NEW SOLAR EDGE P320 OPTIMIZERS,MOUNTED O ON THE BACK OF EACH MODULE. M C AC NEW PV CONDUIT RUN.•SEE EEI.0 CONDUIT SCHEDULE EXTERIOR RUN-----=ATTIC RUN NEW JUNCTION BOX.(MOUNTED TO PV MODULE) EXISTING UTILITY METER: #069936621 V/o O O vivint.Solar 1.877.404.4129 MEKALATOS RESIDENCE 32 BOW ST SALEM,MA,01970 UTILITY ACCOUNT#:25732-93019 SITE PLAN SERVICE#:S-6038718 REGIONAL CENTER: OPERATING CENTER:MA-01 DATE:1/19R019 SCALE:114"=1'-Y DRAWN BY:DIN i a MOUNTING LEGEND NG a SFM-9"ATTACHED SPLICE ® S 1.0 Nor TO scALe SFM-TRIMRAIL WITH 1 SFM-ROOF ATTACHMENT r2 SECTION VIEW 3 ROOF ATTACHMENT s SFM-3"RAIL S 1.D NOT TO SCALE $1.0 NOT TO SCALE S I.D NOT TO SCALE S 1.0 NOT TO SCALE SFM 9'ATTACHED SPLICE CAMP.ATTACHMENT CLAMPr ATTACHMENT COUPLING COUPLING SFM 9'SPLICE MODULE SFM 3' ILSCO SGB-4 GROUNDING LUGS RAF ER S1.o NOT TO MODULE RHFTER 9 MODULES IN PORTRAIT LANDSPACE T"MRAIL SPLICE NDT TO SCALE 5 1.0 TRIMRAIL ROOF ATTACHMENT,SEE TABLE s SFM LAYOUT eSFM 9"SPLICE RIMRAIL $1.D NOT TO SCALE $1 D NOT TO SCALE I��CANTA-E�VER V30R�LE59 �•` vivi■M■iTtY.Solar O I I RTRAIT=MA '(4') 1.977.404.4129 C' COUPLING GIAMP 1 E MAx MOOULE 33mm PROFILE MEKALATOS RESIDENCE RAFTER 32 BOW ST SALEM,MA,01970 PV SYSTEM MOUNTING DETAIL 11 SFM-TRIMRAIL 1 UTILITY ACCOUNT#:25732-93019 10 5 T.0 NOT TO SCALE NOT TO SCALE ' 40mm PROFILE SERVICE p:SE038710 MOUNT DETAILS OPERATING IONCENTERNIA-0, S 1 .0 DATE:1/10019 SCALE:NOT TO SCALE DRAWN BY:DIN Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 8680 Tag k Description Wire Gauge p of Conductors/Color Conduit Type Conduit Size o, AC System Size(Watts) 7600 1 PV Wire SO AWG 2(V+,V-) N/A-Free Air N/A-Free Air a, m Total Module Count 28 1 Bare Copper Ground-EGC 6 AWG 1 BARE N/A-Free Air N/A-Free Air c o O1 2THWN-2 12AWG 4(2V+,2V-)B/R EMT 1/2" N 2THWN-2-EGC 12AWG 1(GRN) EMT 1/2" 3 THWN-2 8AWG, 31(11-111-21N)B/R/W EMT 3/4" o m 3THWN-2-EGC 10 AWG 1(GRN) EMT 3/4" m w u 4 THWN-2 16 AWG 3(11-11L2 1N)B/R/W JEMT 3/4" 4THWN-2-GEC 18AWG 1(GRN) JEMT 3/4" L 0 a a N a 0 a Solar Edge SE760OH-US -1 'Conforms to ANSI ut u C12.1-2008 PV System SMART Meter Rapid Shutdown Point of Interconnection,Supply Side Z m O Disconnect,Square D 705.12(A) j DUZ22RB 240W60A > 2 '• Square D222NRB Unfused,NEMA3,or 240V/60A Fused,NEVI w or equivalent with 75°C w Z equivalent,with 75°C , tJ terminations Q Q terminationss V rr, STRING 2:14 PV t 2 IVI Z _E MODULES eristing ice Pa net, SHEET W/OPTIMIZERS Service Panel,single NAME: Phase,with 100A Main _ LOAD - Disconnect 1 °° c STRING 1:14 PV 1 2 14 ITLL 0A A C 3 J � MODULES NEMA4Junc[,on Box 3 LINE", INE tL Jf th p W/OPTIMIZERS 3 3 3 4 SHEET Minimum GECsizeg NUMBER: AWG copper 28PV MODULES PER INVERTER CERTER=6680 WATTS Isl c a e knife'AC Isl c a le'Knife' Disconnect Disconnect,In Sight of Tap W