Loading...
B-17-824 - 0034 BALCOMB STREET - Building Permit The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF q_ �! JA Massachusetts State Building Code,790 CMR SALEM �J Revised liar 2011 1 Building Permit Application To Construct.Repair,Renovate Or Demolish a (� One-or Two-Family Dwelling This Section For Official Use Only 1 Building Permit Number: Date p ied: Building Official(Print Name) Signature Date 1 SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 34 Balcomb St. 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zonin-District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: Outside Flood Zone? Public❑ Private❑ Check if yes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Aida Garcia Salem, MA 01970 Name(Print) City,State,ZIP 34 Balcomb St. 978-210-9794 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORfe(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other S(Specity: Solar Brief Description of Proposed Work`: Install 1.71 kw solar panels on roof.Will not exceed roof panel, but will add 6" to roof height.6 panels total. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) L Building $ 1,000 1. Building Permit Fee: $ Indicate how fee is determined: ❑ Standard City/Town Application Fee 2.Electrical $ 6,000 ❑Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Su ression) Total All Fees: $ Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ 7,000 ❑Paid in Full ❑Outstanding Balance Due: r • SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 88720 4/10/18 Paul Eaton License Number Expiration Date Name of CSL Holder 20 Patterson Brook Rd. Unit 1 List CSL Type(see below) U No.and Street Type Description U Unrestricted(Buildings u to 35,000 cu.ft.) W.Wareham, M 02576 R Restricted 1&2 Family Dwelling City./Town,State,ZIP �/� n � M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances (508)291-0007 brittany.nunes@tdnitysolarsystems.com I Insulation Telephone Email address D Demolition 5.2 .Registered Home Improvement Contractor(HIC) 170355 10/12(17 Paul Eaton/Trinity Heating&Air DBA Trinity S HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 20 Patterson Brook Rd. Unit 1 _ brittany.nunes@trinitysolarsystems.com No.and Street Email address W.Wareham, MA 02576 (508)291-0007 City,/Town,State.ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........If No...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Paul Eaton to act on my behalf,in all matters relative to work authorized by this building permit application. Please see attached letter. 8/25/17 Print Chvner's Name(Electronic Signature) Date SECTION 7b: OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained ui this application e and accurate to the best of my knowledge and understanding. Paul Eaton 8/25/17 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building pemut to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important infomlation on the HfC Program can be found at xativvy.mass.gov°/oca Information on the Construction Supervisor License can be found at w-ww.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics.decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/batlhs Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "'l'otal Project Square Footage"may be substituted for"Total Project Cost" ECTOR E n G I rl E E R S Project Number: U2041-0451-171 August 21,2017 Trinity Solar 20 Patterson Brook Road,Unit#1 W.Wareham,MA 02576 ATTENTION: Ashley Grey REFERENCE: Aida Garcia Residence:34 Balcomb Street,Salem,MA 01970 Solar Panel Installation Dear Ms.Grey: Per your request, we have reviewed the attached layout and photos relating to the installation of solar panels at the above-referenced site.The following materials and components are proposed in the installation of the solar panels. Roof Structure:2x6 rafters at 26"O.C.with 13'-0"span Roof Material:Composition Shingles Mounting Connections: 5/16"Lag Screw with 2.5"Embedment at 6' O.C.maximum. Based upon our review,it is our conclusion that the installation of solar panels on this existing roof will not adversely affect the structure of this house. The design of solar panel supporting members is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2009 International Residential Code and ASCE 7-05. Appropriate design parameters which must be used in the design of the supporting members and connections are listed below: Ground snow load:50 psf per Massachusetts amendments to the IRC(verify with local building department) Design wind speed for risk category II structures: 105 mph(3-sec gust) Wind exposure:Category C Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight related to the solar panels is less than 3.5 pounds per square foot.In the area of the solar panels,no 20 psf live loads will be present. Regarding snow loads,it is our conclusion that since the panels are slippery,effective snow loads will be reduced in the areas of the panels. The attached calculations'verify the capacity of the connections against wind,the governing load case. Solar panels will be flush-mounted, parallel to and no more than 6" above the roof surface. Thus, it is our conclusion that any additional wind or seismic loadings related to the addition of these solar panels is negligible. During design and installation,particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of solar panel support span tables provided by the manufacturer is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables. Attachments to existing roof joist or rafters must be staggered so as not to over load any existing structural member. Waterproofing around the roof penetration is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLCgN F o� 'ROGER T. .yG ALW ORTH No.41740 A qRoaer h,P.E. 9��F SQOS7E�N����4�Q NAL Principal RTA/kbh 8/21/2017 651 W.Galena Park Blvd./Draper,UT 84020 /T(801)990-1775/F(801)990-1776/www.vectorse.com other offices:Layton,UT•St.George,UT•Laguna Hills,CA•Mesa,AZ Page 1 of 2 JOB NO.: U2041-0451-171 =CTOR E n G i n E E R s PROJECT: ALDA GARCIA RESIDENCE SUBJECT: WIND PRESSURE Com onents and Cladding Wind Calculations Label: Note: Calculations per ASCE 7-05 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 105 Notes: Exposure Category: C ` Occupancy Category: II Importance Factor I: 1.00 ADDITIONAL INPUT & CALCULATIONS: Height of roof, h [ft] s;6- (Approximate) Comp/Cladding Location a le R 7" M CIS Enclosure Classification `closed Bii cfngs t Zone 1 GCP Figure 6-1,1D (enter largest abs. value) Zone 2 GCP y (enter largest abs. value) Zone 3 GCP 1F (enter largest abs. value) a: 9.5 Table 6-2 zg [ft]: 900 Table 6-2 Kh: 1.021 Table 6-3 Kt: 1 Equation 6-3 Kd: 0.85 Table 6-4 Velocity Pressure, qh [psf]: 24.5 Equation 6-15 GCP;: 0 :Figure 6-5 (largest abs. value) OUTPUT: p =qh GCP —(GCPj]j Zone 1 Pressure, p [psf]:. 24.49 psf (1.OW, Interior Zones) Zone 2 Pressure, p [psf]: 29.38 psf (1.OW, End Zones*) Zone 3 Pressure, p [psf]: 29.38 psf (1.OW, Corner Zones*within a) (*a=assumed=3') Page 2 of 2 TF:Z JOB NO.: U2041-0451-171 E n E i n. E E R S PROJECT: ALDA GARCIA RESIDENCE SUBJECT: CONNECTION CAPACITY Lag Screw Connection Capacity: Demand: Lag Screw Size 5/1 Cd 1.6 Pressure Max Max. Trib. Max. Uplift (1.0 Wind) Spacing Area Embedment � 5 � in (psf) (ft) (ft2) Force (Ibs) Grade AS"' Capacity ZC15 ; Ibs/in. emb. Zone 1: 24.5 18 441 Number of Screws ° _ Zone 2: 29.46� 18 529 Total Capacity: 820 Ibs Zone 3: 29.4 6 18 529 Demand< Capacity: CONNECTION OKAY