Loading...
B-17-676 - 0065 APPLETON STREET - Building Permit I'10 The Commonwealth of Massachusetts t Board of Building Regulations and Standards CITY OF �Q Massachusetts State Building Code,780 CMR s�1 SALEM Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: D e Applied: _ I Building Official(Print Name) Signature Da SECTION 1:SITE INFORMATION 1. Illperty Address: 1.2 Assessors Map&Parcel Numbers N ' L 1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) L7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood`!_one? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Jennifer Tran Salem MA 01970 f-Name,(Print)# City,State,ZIP 65 appletOn St 9784567874 Aminpat2003@yahoo.com No.and Street Telephone Email Address . SECTION 3: DESCRIPTION OF PROPOSED WORKZ(check all that apply) New Constructioa'ff Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ 1 Number of Units Other ❑ Specify: Brief cspription of Proposed Work`: SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials) Official Use Only 1.Building $Z 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Application Fee 2. Electrical $ ❑Total Project Cost'(item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ .4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ ` ' Check No. Check Amount: Cash Amount: 6.Total Project Cost: $� �(1 0 Paid in Full 13 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) ` r !� a — 1�Q PQ l c'i ,—k License Number ExptraUon 171atc Nu c tiI tt. I der y ^ U List CSL Type(see below) No.at vl 'trcet l U �\ Type Description U Unrestricted(Buildings up to 35.000 cu.ft. ( + R Restricted 1&2 Family Dwelling Cityrl'own.Mate_/.,II' J M Masonry RC Roofing Covering WS Window and Siding I r SF Solid Fuel Burning Appliances l ( 1 Vf YA 0 COV q l( G I I Insulation Telephone Email address D Demolition 5.2 Registered Ilorn Imps ement Contractor(HIC)tr '1M^1 ) rj EIIC Registration Number Expiration Date HIC Company Nat r.I IIC. Rq strantVNIV Namt, y./i No.and Street 4 1 Email address Ci /Town,State.Z1P '1'ele hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........Er-� No............❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject prop rty,hereby authorize 4 to act on my behalf,in a I s relative to work authorized by this building permit application. ,Print Owner's Name(Electronic 5 gnature� Date,-1 SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print O� of s or Authorize Agent' Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass. og v/oca Information on the Construction Supervisor License can be found at ww.w.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 0 WOVO��o SO a 1800 W Ashton Blvd. J V it Lehi, UT 84043 Structural Group Jon P. Ward, SE, PE J. Matthew Walsh, SE, PE Clint C. Karren, PE Structural Engineering Manager Senior Structural Engineering Manager Structural Engineering Manager ion.wardOvivintsolar.com james.walshC@vivintsolar.com clintkarrenC@vivintsolar.com July 20, 2017 Re: Structural Engineering Services Tran Residence 65 Appleton St, Salem, MA S-5663925; MA-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a representative from our office under my supervision identifying specific site information including size and spacing of members for the existing roof structure. 2. Proposed layout of the system including connection details for the solar panels. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components and consists of the following: Roof Sections (1 and 2): Dimensional lumber - 2x6 at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. B. Loading Criteria 8.49 PSF= Dead Load (roofing/framing) 2.59 PSF= Dead Load (solar panels/mounting hardware) 11.08 PSF=Total Dead Load 40 PSF=Ground Snow Load (based on local requirements) Wind speed of 100 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C.Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (www.ecolibrium solar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 11/2' thick and mounted 41/2' off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir. Based on our evaluation, the Page 1of2 VoVuLI i solar I Page 2 of 2 pullout value, utilizing a penetration depth of 21/2", is less than the maximum allowable per connection and therefore is adequate. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph A above, using the wind load uplift procedures of ASCE 7-10 and is specified below. The following values have been verified by in- house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections shall be staggered to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 72 72 72 48 48 48 Max Uplift Load Ibs 179 148 140 302 249 237 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me, �AA OF ,{ Regards,, Jon P. Ward, SE, PE ARP c MA License No. 52584 y 140 S25 ST sS/ONAL EN `lk vowoni solar 0 c t� oG.O O S ` •� zoz �ym� U7 N v cm z I x z nax -C m gyX no g °$ m �sm ^'=m ono z"�o c z'i I - m3 17 ^ Tny I �o (n a� im N N m .0<M. I m ay g m I ---------------------------------� O O I O i O O O `----------------------------------J 65 APPLETON ST, SALEM MA 01970 � G D I- (n { n (n c � 6 m 3 g m ® ® ❑ 0 ❑ � m r- x x ya o z; Z. OA OA i 3 O— — y < — Nz C� C� T M. Na Z 0 INSTALLER:VIVINT SOLAR Tran Residence PV 1.0 K m SITE m INSTALLER NUMBER:1.877.494.4129 �p io g 65 APPLETON ST m PLAN m� MA LICENSE; viva t. o 1 6 SALEM,MA 01970 5663925 Oesi99ec— L,gMWified:7119/20177:43AM Utility Acc.#8810342064 CLAMP+ATTACHMENT COUPLING 0 Zoo f E i °<� MODULE CLAMP+ATTACHMENT as w PERMITTED N i COUPLING CLAMP SPACING CLAMP ASSEMBLY (INCLUDES GLIDER) LEAF SPRING RAFTER I 1I T GLIDER RAFTER F STRUT NUT 0 L=P� ORTRAIT MODULE cn CLAMP SPACING ECOX BASE SEALING WASHER � FLASHING COMP SHINGLES IL=LANDSCAPE CLAMP SPACING •c 1 MODULES IN PORTRAIT LANDSCAPE PV 3.0 _NOT TO SCALE N 6/16"X41/2" E SS LAG SCREW TORQUE=13t2 FT-LBS MOUNT DETAIL'ECOX 2 MOUNTING z WITH METAL FLASHING a $ N PV 3.0 NOT TO SCALE m PV 3.0 DETAIL • E o CANTILEVER U3 OR LESS N _ rn PV MODULES,TYP.MOUNT —�� L=MAX64" OF COMP SHINGLE ROOF, / SHEET PARALLEL TO ROOF PLANE COUPLING CLAMP NAME: F w J MODULE 5 O � p PV ARRAY TYP. ELEVATION RAFTER SHEET NOT TO SCALE NUMBER: 3 PV SYSTEM M®UNTING DETAIL N PV 3.0 NOT TO SCALE Photovoltaic System Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) DC System Size(Watts) 6555 Tag If Description Wire Gauge If of Conductors/Color Conduit Type Conduit Size AC System Size(Watts) 7600 1 PV Wire 10 AWG 2(V+,V-) N/A-Free Air N/A-Free Air o Total Module Count 23 1 Bare Copper Ground(EGC/GEC) 6 AWG 1 BARE N/A-Free Air N/A-Free Air o v 2 THWN-2 10 AWG 4(2V+,2V-)B/R EMT 3/4" 2 THWN-2-Ground 8AWG 1(GRN) EMT 3/4" c 0 4 00 3THWN-2 8AWG 3(1L11L2 IN)B/R/W EMT 3/4" z eL w c'o 3THWN-2-Ground 8AWG 1(GRN) EMT 3/4" m Q � e N 0 n w u V ry V a V n Solar Edge SE760OA-US 'Conforms to ANSI ri N C32.1-2008;Rapid op shutdown disconnect is DC Z o switch. Point of Interconnection,Load > Square D DU222RS, Side 705.12(B)(3)(b) Z Iii 240V/60A,Unfused, NEMA3,orequivalent, '� tj N wi th 7S°C terminations ul2N N Q m ut Q e STRING 2:12 PV 1 2 12 V R�A SHEET MODULESES I V I NAME: Op, Existing 240V/200A C Service Panel,Single C 3r STRING 1:11 PV 1 2 11 \ Phase,with 200A Main ` MODULES NEMA4Junction Box 3 Disconnect M C with Irreversible 3 3 OA SHEET Ground Splice(TYP) NUMBER: 23 PV MODULES PER INVERTER=6555 WATTS STC Visl le Lockable'Knlfe'q/C Minimum GECsize4 14 Disconnect AWG copper W