B-19-565 - 0008 ALMEDA STREET - Building Permit LA 5r sq ~ The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY Massachusetts State Building Code,780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct,Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applied: 130dm�g Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 8 Almeda Street 14 113 .� 1.1a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: _ R1 Single Family Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes[] SECTION 2: PROPERTY OWNERSHIP' 2A Owner'of Record: _ Abul Kalam Salem,MA 01970 Name(Print) City,State,ZIP _8 Almeda Street 857-247-9884 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORKZ(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units Other X Specify: Rooftop Solar Brief Description of Proposed Work: Installation of an interconnected rooftop PV system. 38 (290w) panels 11.02 kw dc. No structural per PE SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ 6,447 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $ 5,042 [I Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Total All Fees:$ Su ression Check No. Check Amount: Cash Amount: 6.Total Project Cost: $21,489 ❑Paid in Full ❑Outstanding Balance Due: `l 5 u` SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-040622 81112019 Stephen Kelly License Number Expiration Date Name of CSL Holder List CSL Type(see below) 200 Research Drive No.,and Street Type Description U Unrestricted Buildings u to 35,000 cu.ft. Wilmington, MA 01887 R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofmg Covering WS Window and Siding SF Solid Fuel Burning Appliances 978-793-7881 mapermits@sunrun.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 180120 10/13/2020 Sunrun, Inc HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 200 Research Drive mapermits(aD-sunrun.com No.and Street Email address Wilmington MA 01887 978-793-7881 Ci /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........V, No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Stephen Kelly to Pict on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. _ Stephen Kell zA ,f L 9•.Wi 9 Print Owner's or Authorized Agent's Name(EIV&onic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of halUbaths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" JRZO structural May 28,2019 ENGINEERS Sunrun Inc. 133 Technology Dr,Suite 100 Irvine,CA,92618 Subject:Structural Certification for Installation of Solar Panels Job Number:19-04638 Client:Abul Kalam-222R-008KALA Address:8 Almeda St,Salem,MA 01970 Attn.:To Whom It May Concern A field observation of the condition of the existing framing system was performed.by an audit team from Sunrun Inc.. From the field observation of the property,the existing roof structure was observed as follows: The existing roof structure consists of: • Composition Shingle over Roof Plywood is supported by 2x12 @ 16"o.c.SPF#2 at ARRAY 1.The rafters are sloped at approximately 33 degree and have a maximum projected horizontal span of 15 ft 10 in between load bearing supports. • Composition Shingle over Roof Plywood is supported by 2x12 @ 16"o.c.SPF#2 at ARRAY 2.The rafters are sloped at approximately 32 degree and have a maximum projected horizontal span of 17 ft 2 in between load bearing supports. • Composition Shingle over Roof Plywood is supported by 2x12 @ 16"o.c.SPF#2 at ARRAY 3-4.The rafters are sloped at approximately 20 degree and have a maximum projected horizontal span of 10 ft 4 in between load bearing supports. Design Criteria: • Applicable Codes=780 CMR,ASCE 7-10,and NDS-15 • Ground Snow Load=50 psf;Roof Snow Load=32.1 psf ARRAY 1;33 psf ARRAY 2;34.7 psf ARRAY 3-4 • Roof Dead Load=14.3 psf ARRAY 1;14.2 psf ARRAY 2;12.8 psf ARRAY 3-4 • Basic Wind Speed=127 mph Exposure Category C As a result of the completed field observation and design checks: • ARRAY 1:is adequate to support the loading imposed by the installation of solar panels and modules.Therefore,no structural upgrades are required. • ARRAY 2:is adequate to support the loading imposed by the installation of solar panels and modules.Therefore,no structural upgrades are required. • ARRAY 3-4:is adequate to support the loading imposed by the installation of solar panels and modules.Therefore,no structural upgrades are required. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to,the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements without structural upgrade in accordance with the 780 CMR. If you have any questions on the above,do not hesitate to call. Prepared By: � �C" PAUL K. G PZSE,Inc.-Structural Engineers ZACHER. Roseville,CA „STRUCTURAL No.5010 �^; � 0613a 2 ' FSSlON{l 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience I integrity J Ernpowermeni r Rza structural May ?8,2019 ENGINEERS Sunrun Inc. 133 Technology Dr,Suite 100 Irvine,CA,92618 Attn.:To Whom It May Concern re:Job 19-04638 :Abul Kalam-222R-008KALA The following calculations are for the structural engineering design of the photovoltaic panels located at 8 Almeda St,Salem, MA 01970.After review, PZSE, Inc. certifies that the roof structure has sufficient structural capacity for the applied PV loads. If you have any questions on the above,do not hesitate to call. �.SN OF* � PAUL K_ Prepared By: ZACHER PZSE,Inc. -Structural Engineers STRUCTURAL No 50100 Roseville, CA O��SSIpNAL 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W, www.pzse.com Experience i Integrity i 1:rr ^,ver ent PZH Project:Abul Kalam--Job#: 19-04638 - Date: 5/28/2019 Engineer: NC Gravity Loading Roof Snow Load Calculations pg=Ground Snow Load= 50 psf CQ=Exposure Factor= 0.9 (ASCE7-Table 7-2) C,=Thermal Factor= 1.1 (ASCE7-Table 7-3) 1=Importance Factor= 1 pf=0.7 C.C,I pg 35 psf (ASCE7-Eq 7-1) where pg 5 20 psf,Pf min=I x pg= N/A where pg>20 psf,Pf min=20 x I= N/A Per ASCE 7-10,minimum values of Pf shall apply to hip and gable roofs with slopes less than 15-. Therefore,pf=Flat Roof Snow Load= 35 psf ps=C:pf (ASCE7-Eq 7-2) Cs=Slope Factor= 0.925 ARRAY 1 Cs=Slope Factor= 0.950 ARRAY 2 Cs=Slope Factor= 1.000 ARRAY 3-4 Ps=Sloped Roof Snow Load= 32.1 psf ARRAY 1 Ps =Sloped Roof Snow Load= 33.0 psf ARRAY 2 Ps=Sloped Roof Snow Load= 34.7 psf ARRAY 3-4 PV Dead Load=3 psf(Per Sunrun Inc.) I r_- Roof'Live Load= 16.21 psf ;ARRAY 1 Roof Live Load= 16.50 psf IARRAY 2 J Roof Live Load= _ 29.63 psf 1ARRAY 3-4 Note:Roof live load is removed in area's covered by PV array. i Roof Dead Load ARRAY 1 Composition Shingle 4.00 Roof Plywood 1.50 2x12 Rafters @ 16"o.c. 2.31 Vaulted Ceiling 4.00 CeilingVaulted Miscellaneous 0.19 Total Roof DL ARRAY 1 12.0 psf DL Adjusted to 33 Degree Slope 14.3 psf Roof Dead Load ARRAY 2 Composition Shingle 4.00 Roof Plywood 1.50 2x12 Rafters @ 16"o.c. 2.31 Vaulted Ceiling 4.00 CeilingVaulted Miscellaneous 0.19 Total Roof DL ARRAY 2 12.0 psf DL Adjusted to 32 Degree Slope 14.2 psf Roof Dead Load ARRAY 3-4 , Composition Shingle 4.00 Roof Plywood 1.50 2x12 Rafters @ 16"o.c. 2.31 Vaulted Ceiling 4.00 CeilingVaulted Miscellaneous 0.19 Total Roof DL ARRAY 3-4 12.0 psf DL Adjusted to 20 Degree Slope 12.8 psf 2of7 i Project: Abul Kalarn--Job#: 19-04638 Date: 5/28/2019 Engineer: NC Wind Calculations Per ASCE 7-10 Components and Cladding Input Variables Wind Speed 127 mph Exposure Category C Roof Shape Gable Roof Slope 33 degrees Mean Roof Height 22 ft Building Least Width 36 ft Effective Wind Area 14.6 sf Roof Zone Edge Distance,a 3.6 ft Controlling C&C Wind Zone Zone 3 Design Wind Pressure Calculations Wind Pressure P=qh*(G*Cp) qh=0.00256*Kz*Kzt*Kd*VA2 (Eq.30.3-1) Kz(Exposure Coefficient)= 0.916 (Table 30.3-1) Kzt(topographic factor)= 1 (Fig.26.8-1) Kd(Wind Directionality Factor)= 0.85 (Table 26.6-1) V(Design Wind Speed)= 127 mph (Fig.26.5-1A) Risk Category= II (Table 1.5-1) qh= 32.1 psf 0.6*qh= 19.29 Standoff Uplift Calculations Zone 1 Zone 2 Zone 3 Positive GCp= -0.99 -1.67 -2.57 0.89 Uplift Pressure= -19.09 psf -32.30 psf -49.57 psf 17.26 psf Attachment Dead Load= 3.00 psf 3.00 psf 3.00 psf Max Rail Span Length= 2.67 2.67 2.67 Longitudinal Length= 5.46 5.46 5.46 Attachment Tributary Area= 14.56 14.56 14.56 Attachment Uplift= -252.00 -444.00 -695.00 Lag Screw Uplift Capacity Check Fastener= 5/16 inch Number of Fasteners= 1 Minimum Threaded Embedment Depth= 2.5 inch Withdraw Capacity Per Inch= 205 Ib (NDS Eq 12.2-1) Allowable Withdraw Capacity= 8201b (NDS Eq 11.3-1) 820lb capacity>695 lb demand Therefore,OK Lag Screw Shear Capacity Check # Embedment Depth Reduction Factor 1 Lateral Force from Gravity Loads= 279 lb Attachment Lateral Capacity= 288 Ib (NDS Table 12K) 287.5 lb capacity>279 lb demand Therefore,OK 3 of 7 I ' RAZE Project:Abul Kalam--Job#: 19-04638 Date: 5/28/2019 Engineer: NC Framing Check ARRAY 1 PASS w=66 plf Dead Load 14.3 psf PV Load 3.0 psf Snow Load 32.1 psf2x12 Rafters @ 16"o.c. Member Span=15'-10" Governing Load Comb. DL+SL Note:Attachments shall be Staggered. Total Load 49.4 psf Member Properties I Member Size S(in A3) 1(inA4) Lumber Sp/Gr Member Spacing 2x12 31.64 177.98 SPF#2 @ 16"o.c. Check Bending Stress Fb(psi)= f'b x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1 x 1.15 Allowed Bending Stress=1157.1 psi Maximum Moment = (wLA2)/8 = 2064.05 ft# = 24768.6 in# Actual Bending Stress=(Maximum Moment)/S =782.9 psi Allowed>Actual--67.7%Stressed -- Therefore,OK Check Deflection 1 Allowed Deflection(Total Load) = L/180 (E=1400000 psi Per NDS) = 1.055 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) _ (5*w*LA4)/(384*E*I) = 0.254 in = L/749 < L/180 Therefore OK Allowed Deflection(Live Load) = L/240 0.791 in Actual Deflection(Live Load) _ (5*w*LA4)/(384*E*I) 0.243 in L/782 < L/240 Therefore OK Check Shear Member Area= 16.9 inA2 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 2278 lb Max Shear(V)=w*L/2 = 521 lb Allowed>Actual--22.9%Stressed -- Therefore,OK 4 of 7 r Project:Abul Kalam--Job#: 19-04638 Date: 5/28/2019 Engineer: NC Framing Check ARRAY 2 PASS w=67 plf Dead Load 14.2 psf PV Load 3.0 psf Snow Load 33.0 psf { 2x12 Rafters @ 16"o.c. 4� Member Span=17'-2" �J Governing Load Comb. DL+SL Note:Attachments shall be Staggered. Total Load 50.2 psf Member Properties Member Size S(in^3) I(in^4) Lumber Sp/Gr Member Spacing 2x12 31.64 177.98 SPF#2 @ 16"o.c. Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1 x 1.15 Allowed Bending Stress=1157.1 psi Maximum Moment = (wLA2)/8 = 2465.61 ft# = 29587.3 in# Actual Bending Stress=(Maximum Moment)/S =935.2 psi Allowed>Actual-80.9%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = L/180 (E=1400000 psi Per NDS) = 1.144 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) _ (5*w*L^4)/(384*E*I) = 0.353 in = L/584 < L/180 Therefore OK Allowed Deflection(Live Load) = L/240 0.858 in Actual Deflection(Live Load) _ (5*w*LA4)/(384*E*I) 0.346 in L/596 < L/240 Therefore OK Check Shear Member Area= 16.9 inA2 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 2278 lb Max Shear(V)=w*L/2 = 575 Ib Allowed>Actual--25.3%Stressed -- Therefore,OK 5of7 Project: Abul Kalam--Job#: 19-04638 FI—H Date: 5/28/2019 Engineer: NC Framing Check ARRAY 3-4 PASS w=67 plf Dead Load 12.8 psf PV Load 3.0 psf _ Snow Load 34.7 psf ' 2x12 Rafters @ 16"o.c Member Span=10'-4" Governing Load Comb. DL+SL Note:Attachments shall be Staggered. Total Load 50.5 psf Member Properties Member Size S(in^3) I(in^4) Lumber Sp/Gr Member Spacing 2x12 31.64 177.98 SPF#2 @ 16"o.c. Check Bending Stress Fb(psi)= f b x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1 x 1.15 Allowed Bending Stress=1157.1 psi Maximum Moment (wLA2)/8 = 898.713 ft# = 10784.6 in# Actual Bending Stress=(Maximum Moment)/S =340.9 psi Allowed>Actual-29.5%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = L/180 (E=1400000 psi Per NDS) = 0.688 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) _ (5*w*LA4)/(384*E*I) = 0.049 in = L/2531 < L/180 Therefore OK Allowed Deflection(Live Load) = L/240 0.516 in Actual Deflection(Live Load) _ (5*w*L^4)/(384*E*I) 0.050 in L/2480 < L/240 Therefore OK — - - -- -- —• - — -- Check Shear — — - --_-- - --- -- -- Member Area= 16.9 inA2 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 2278 lb Max Shear(V)=w*L/2 = 348 Ib _ Allowed>Actual--15.3o�Stressed - Therefore OK 6of7 Project: Abul Kalarn--Job#: 19-04638 FI-8 Date: 5/28/2019 Engineer: NC Lateral Check:780 CMR Existing Weight of Effected Building Level Area Weight(psf) Weight(lb) Roof 2880 sf 14.3 psf 41184 lb Ceiling 2880 sf 6.0 psf 17280 lb Vinyl Siding 1701 sf 2.0 psf 3403 lb (14.75'Wall Height Int.Walls 851 sf 6.0 psf 5104 lb Existing Weight of Effected Building 66971 lb Proposed Weight of PV System Weight of PV System(Per Sunrun Inc.) 3.0 psf Approx.Area of Proposed PV System 675 sf Approximate Total Weight of PV System 2025 lb 10%Comparison 10%of Existing Building Weight(Allowed) 6697 lb Approximate Weight of PV System(Actual) 2025 lb Percent Increase 3.0% 6697 lb>2025 lb,Therefore OK Per IEBC 402.4&403.4 and by inspection,portions of the roof that are impacted by installation of the array will be subject to a net reduction in design loading. Therefore,the existing structure may remain unaltered. 7 of 7 i TABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS PAGE# DESCRIPTION • SYSTEM SIZE: 11020W DC, 10000W AC • ALL WORK SHALL COMPLY WITH NEC 2017, IBC 2015, MUNICIPAL CODE,AND SOLAR MODULES • MODULES: (38) REC SOLAR: REC290TP2 BLK ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. ED SERVICE ENTRANCE PV-1.0 COVER SHEET INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COM PLY WI TH NEC 2017. PV-2.0 SITE PLAN (1) SOLAREDGE TECHNOLOGIES: SE1000OH-US WITH • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT REVENUE GRADE METERING • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP MAIN PANEL RACKING: GROUNDED IN THE INVERTER. PV-4.0 ELECTRICAL SNAPNRACK RL; FLASHTRACK COMP. SEE DETAIL • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SNR B MOUNT SD-00708 • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SUB-PANEL SNR A MOUNT PV-5.0 SIGNAGE M • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES,ARE CLASS A FIRE RATED. LC PV LOAD CENTER ® CHIMNEY • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). IS-1 SUNRUN METER ATTIC VENT • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). o ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.71 AMPS MODULE SHORT CIRCUIT CURRENT. FLUSH ATTIC VENT • 15.17 AMPS DERATED SHORT CIRCUIT CURRENT[690.8 (a) &690.8 (b)]. PM DEDICATED PV METER • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). o PVC PIPE VENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INVERTER(S)WITH For Structural Only ® METAL PIPE VENT LIMITED TO 80 VOLTS WITHIN 30 SECONDS OF A RAPID SHUTDOWN INITIATION. INV INTEGRATED DC DISCONNECT AND AFCI ® T-VENT I"OFM4s9 s AC AC DISCONNECT(S) PAUL K. SATELLITE DISH ZACHER mt STRUCTURAL 0 DC DISCONNECT(S) FO FIRE SETBACKS 006700�0 CB 1EEillCOMBINER BOX HARDSCAPE o�sS�ONAL- F F_ —1 INTERIOR EQUIPMENT —PL— PROPERTY LINE LE a SHOWN AS DASHED SCALE: NTS A AMPERE sunrun AC AL TERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 200 RESEARCH DR,WILMINGTON,MA 01887 rti »y EXT EXTERIOR PHONE E888.65 .6527 FAX 8 .528.9701 FRM FRAMING INT INTERIOR CUSTOMER RESIDENCE: - The WitCh HnO;@ �salc"nwnchnnusuu LBW LOAD BEARING WALL ABUL KALAM MAG MAGNETIC 8 ALMEDA ST, SALEM, MA, rw y tee' " w` s MSP MAIN SERVICE PANEL 01970 =atom (N) NEW NTS NOT TO SCALE TEL.(857)247-9884 OC ON CENTER APN#:SALE-000014-000000-000113 8A11mdaStreel PRE-FAB PRE-FABRICATED TT PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 222R-008KALA SCIOM S LC. TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 t I� ,ers;iy TYP TYPICAL AM IT MAHAJAN a V VOLTS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET Salem Wands �} REV:A 5/28/2019 J1 ty Forest Rower PAGE p�/� .O Cnnservatit�n r V« Area A ,r ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=3/32"=V-0" SITE PLAN DETAIL-SCALE=3/128"= 1'0" PITCH AZIM AZIM (SQFT) AR-01 33° 231° 2450 359.5 ® AR-02 32° 231° 245° 125.8 AR-03 j 20° i 322° 1 336° 89.9 AR-04 20° 142° 1 156° 107.8 (E) DETACHED STRUCTURE .a; .:`• PL T (E) RESIDENCE A� O O A� (N)ARRAY AR-01 O sunrun SE RAC PM ACINV #180120 200 RESEARCH DR,WILMINGTON,MA 01887 PHONE 888.657.6527 (N)ARRAY AR-03 FAX 805.528.9701 CUSTOMER RESIDENCE: ABULKALAM 8 ALMEDA ST, SALEM, MA, 01970 TEL.(857)247-9884 (N)ARRAY AR-02 APN#:SALE-000014-000000-000113 PROJECT NUMBER: 222R-008KALA �N OF&&% DESIGNER: (415)580-6920 ex3 PAUL K. , �� AMIT MAHAJAN _ CT mi (N)ARRAY AR-04 � STRUCTURAL � SHEET .86 1 SITE PLAN Is�o�ss�ONAL�G\N REV:A 5/28/2019 PAGE PV-2.0 ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX PEN MAX MOD. DESIGN CRITERIA ROOF TYPE MOUNTING DETAIL ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPACING OVERHANG MODULES: AR-01 COMP SHINGLE FLASHTRACK COMP.SEE DETAIL SD-00708 2 STORY VAULTED WOOD RAFTER 2 X 12 10'-6" 16" T-8" 4'-0" 2'-0" REC SOLAR: REC290TP2 BLK MODULE DIMS: AR-02 COMP SHINGLE FLASHTRACK COMP.SEE DETAIL SD-00708 1 STORY VAULTED WOOD RAFTER 2 X 12 19'-0" 16" 3'-8" 2'-8" 1'-3" 65.94"x 39.25"x 1.49"(38mm) AR-03 COMP SHINGLE FLASHTRACK COMP.SEE DETAIL SD-00708 1 STORY VAULTED WOOD RAFTER 2 X 12 6--0" 16" 3'-8" 2'-8" 1'-4" MODULE CLAMPS: Portrait: 8.2"- 16.4" AR-04 COMP SHINGLE FLASHTRACK COMP.SEE DETAIL SD-00708 1 STORY VAULTED WOOD RAFTER 2 X 12 6'-0" 16" 3'-8" 4'-0" 2 0 Landscape: 0"-9.75" D1 -AR-01 -SCALE: 1/8" = 1'-0" D2-AR-02-SCALE: 1/8"= V-0" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 50 PSF PITCH: 33' PITCH: 32' WIND SPEED: AZIM:231° AZIM:231° 2,-1" 1 127 MPH 3-SEC GUST. 6" -E 16'-7" - LAG SCREWS: - 16'-7" 18'-5" , 5/16"x4.0":2.5" MIN EMBEDMENT 1' NOTE: 6" a a ai ❑ 3'-2" INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED ❑ SPANS,AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. 16'-8" PENETRATION SPACING: 4'TYP 16'-8"16'-8" FULLY STAGGERED O 1.4" ROW SPACING: OFA 1.00"BETWEEN ROWS �� A q COLUMN SPACING: 9'-6" I PAUL K. cyG 0.75" BETWEEN COLUMNS ZACHER 3'-2" STRUCTURAL ti 011—} No.�0190 6 0 �.Ob 30 x 23'-11" 11'-1" �SS/ONAk- 6" 18'-8" D3 -AR-03-SCALE: 3/16 - 1 -0 " D4-AR-04-SCALE: 3/16"= V-0" sunrun PITCH: 200 PITCH: 20° AZIM:322° AZIM:142° #180120 - 1'} - 1' 18' 6'-2 6'-7' 6'-8 I� 200 RESEARCH OR,WILMINGTON,MA 01887 PHONE 888.657.6527 FAX 805.528.9701 6" CUSTOMER RESIDENCE: ABUL KALAM 8 ALMEDA ST, SALEM, MA, 5'-6" 01970 2'-8"TYP 10' 10, 10'-6" TEL.(857)247-9884 —4'TYP— APN#:SALE-000014-000000-000113 PROJECT NUMBER: — — — —— 222R-008KALA DESIGNER: (415)580-6920 ex3 In n ITn In 0 0 i I AMIT MAHAJAN �— _14,- SHEET 18'-9" '' LAYOUT NOTE TO INSTALLER APPLIES NOTE TO INSTALLER APPLIES WHERE INDICATED(TYP): WHERE INDICATED(TYP): MAX—PEN. SPACING=2'-8" MAX PEN.SPACING=4'-0" REV:A 5/28/2019 MAX OVERHANG=0'- 11" MAX OVERHANG= 1'-7" PAGE PV_3.O SEE SITE PLAN FOR NORTH ARROW - 120/240 VAC SINGLE PHASE SERVICE OMETER#: M NATIONAL GRID 14020961 UTILITY GRID SUPPLY SIDE TAP 4 I EXISTING 200A (N) LOCKABLE (N)MA SMART SOLAREDGE TECHNOLOGIES: C MAIN BREAKER BLADE TYPE UTILITY SE1000OH-US WITH REVENUE FUSED AC REVENUE GRADE METERING 1 DISCONNECT METER 10000 WATT INVERTER JUNCTION BOX PV MODULES 3 3 2 OR EQUIVALENT 1 REC SOLAR: REC290TP2 BLK (38)MODULES EXISTING c��» n A f «��� e + O _ (�j / OPTIMIZERS WIRED IN: 1 200A — YY (1)SERIES OF(11)OPTIMIZERS FACILITY ( MAIN 60A FUSES (1)SERIES OF(10)OPTIMIZERS LOADS \T PANEL SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(17)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI, RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P320 120/240VAC CONNECTS TO TOP LUGS- �� (LINE AT TOP LOAD AT BOTTOM) FACILITY GROUND CONDUIT SCHEDULE NOTES TO INSTALLER: 1. 17 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. # CONDUIT CONDUCTOR NEUTRAL GROUND 2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN 1 NONE (6) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. 2 3/4"EMT OR EQUIV. (6) 10 AWG THHN/THWN-2 NONE (1)8 AWG THHN/THWN-2 sunrun 3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHNrrHWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 200 RESEARCH DR.WILMINGTON,MA 01887 PHONE 888.657.6527 FAX 805.528.9701 CUSTOMER RESIDENCE: ABULKALAM 8 ALMEDA ST, SALEM, MA, 01970 MODULE CHARACTERISTICS P320 OPTIMIZER CHARACTERISTICS TEL.(857)247-9884 : REC SOLAR: REC290TP2 BLK: 290 W MIN INPUT VOLTAGE: 8 VDC APN#:SALE-000014-000000-000113 OPEN CIRCUIT VOLTAGE: 38.8 V VOLTAGE: 48 VDC PROJECT NUMBER: MAX INPUT VO MAX POWER VOLTAGE: 32.1 V MAX INPUT 11 ADC 222R-008KALA SHORT CIRCUIT CURRENT: 9.71 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 AMIT MAHAJAN SlY.�T Erl� �.�I/�i 1. tR'S T iCS-f�11%-R T ER j SHEET SYSTEM SIZE: 11020 W ELECTRICAL SYSTEM OPEN CIRCUIT VOLTAGE: 17 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 5/28/2019 SYSTEM OPERATING CURRENT: 27.55 A SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0 i l f!I � DA NGER � � 8�, �� n�rA . °. . . &WARNING � , ��•- ;� PHOTOVOLTAIC SYSTEM �Akr'u'��' �ti�w i„n,lr: kfl �k::, H COMBINER PANELS ELECTRICAL SHOCK HAZARD y ° z LABEL LOCATION: DO NOT ADD LOADS LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF 11 DO NOT TOUCH TERMINALS. INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND INTERCONNECTION. LABEL LOCATION: BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):CEC 2016:690.54,NEC 2017:690.54,NEC PHOTOVOLTAIC AC COMBINER(IF TERMINALS ON BOTH THE LINE PER CODE(S):CEC 2016:690.31(G)(3),690.31(G)(4),NEC 2017:690.31(G)(3), 2014:690.54,NEC 2011:690.54 APPLICABLE). AND LOAD SIDES MAY BE 690.31(13)(4),NEC 2014:690.31(G)(3),690.31(13)(4),NEC 2011:690.31(E)(3), PER CODE(S):NEC 2017:705.12(B)(2)(3)(b), 690.31(E)(4),IFC 2012:605.11.1.4 NEC 2014:705.12(D)(2)(3)(c),NEC 2011: ENERGIZED IN THE OPEN 705.12(D)(4) POSITION � � � NOTES AND SPECIFICATIONS: LABEL LOCATION: , .t :'` r : •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE LA LA p 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR INE LOCATION: ),AC DISCONNECT(S),AC COMBINER PANEL APPLICABLE). IF REQUESTED BY THE LOCAL AHJ. •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE PER CODE(S):NEC 2017:692.17 `tv sd WORDS,COLORS AND SYMBOLS. q. • •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING u ® ® METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF LABELS OR &WARNINGK. MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO CHANGES,SHALL " BE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE. POWER SOURCE OUTPUT = .LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT CONNECTION LABEL LOCATION: F INVOLVED. DO NOT RELOCATE THIS ON OR NO MORE THAN 1 M(3 FT)FROM THE SWITCH. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY PER CODE(S):NEC 2017:690.56(C)(3) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. OVERCURRENT DEVICE •DO NOT COVER EXISTING MANUFACTURER LABELS. LABEL LOCATION: ADJACENT TO PV BREAKER(IF APPLICABLE). PER CODE(S):NEC 2017:705.12(B)(2)(3)(b) INVERTER 1 &I ;ARN I N G SOLAR 'PV SYSTEM EQUIPPED - • ' 27.ss .. DUAL POWER SUPPLY WITH RAPID SHUTDOWN 0 SOURCES: UTILITY GRID sunrun AND PV SOLAR ELECTRIC •- 4s 4 � SYSTEM LABEL LOCATION: INVERTER(S),DC DISCONNECT(S). LABEL LOCATION: PER CODE(S):CEC 2016:690.53,NEC 2017:690.53,NEC UTILITY SERVICE METER AND MAIN TURN RAPID SHUTDOWN 90wR ELECTRIC 2014:690.53,NEC 2011:690.53 #180120 SERVICE PANEL. SWITCH TO THE OFF PER CODE(S):NEC 2017:705.12(13)(2)(3)(b), NEC 2014:705.12(D)(3),NEC 2011: POSITION TO SHUT DOWN 200 RESEARCH DR,WILMINGTON,MA 01887 PHONE 888.657.6527 PV SYSTEM AND REDUCE 705.12(D)(4) FAX 805.528.9701 11 SHOCK HAZARD IN THE CUSTOMER RESIDENCE: ! AIRN I N G ARRAY. 8 ALMEDA ST, SALEM, MA, 01970 THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL LABEL LOCATION: TEL.(857)247-9884 RATING OF ALL ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE APN#:SALE-000014-000000-000113 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS OVERCURRENT DEVICES ARE CONNECTED. PROJECT NUMBER: EXCLUDING MAIN SUPPLY PER CODE(S):NEC 2017:690.56(C)(1)(a) 222R-008KALA OVERCURRENT DEVICE SHALL DESIGNER: (415)580-6920 ex3 NOT EXCEED AMPACITY OF AMIT MAHAJAN BUSBAR. J SHEET LABEL LOCATION: SIGNAGE UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):CEC 2016:705.12(D)(2)(3)(c),NEC 2017: REV:A 5/28/2019 705.12(B)(2)(3)(b),NEC 2014:705.12(D)(2)(3)(c),NEC 2011:705.12(D)(4) PAGE PV-5.0