Loading...
35 Flint Street American Standard heatpump 4*w" s7�tffda-d. HEATING & AIR CONDITIONING Submittal Split System Heat Pump 4A6H6036H1000A _ 1111__IN [[[[[[ llllllllllllllll [[[[[[[[[[[[[[ llllllllllllllll [[[[[[[[[[[[[[ llllllllllllllll [ [[[[[[[[[[[[[ Note: "Graphics in this document are for representation only.Actual model may differ in appearance." TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December2014 4A6H6036H-SUB-1A-EN "HingersollRand l�cP�lcati! Ste . H EATING & Al R CONDITIONING B C SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES, 1, TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF ATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOUL BE AT LEAST 305 (12") FROM YIALL AND ALL SURROUNDING SHRUBBERY ON TV10 SIDES, OTHER TWO SIDES UNRESTRICTED, ELECTRICAL SERVICE PANEL K 25 fl) A 22,2 (718) DIA. HOLE LOW VOLTAGE 28,6 (1-1/8) DIA, K,O, WITH 22,2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY H F ELK,O, FOR ALTERNATE LIQUID LINE SERVICE VALVE, J7 G ECTRICAL ROUTING 'E' I,D, FEMALE BRAZE CONNECTION WITH IN,, SAE GAS LINE 114 TURN BALL SERVICE VALVE, "D' FLARE PRESSURE TAP FITTINGS, I,D. FEMALE BRAZED CONNECTION WITH 114" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A6H6036H 4 943 946 870 3/4 3/8 143 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (5-5/8)5) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H6036H 70 75 1 69 68 68 66 62 57 51 Note:Rated in accordance with AHRI Standard 270-200866 2 4A6H6036H-SU13-1A-EN l�cP�lcati! S�i . H EATING & Al R CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A6H6036H1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ<<) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BIRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 M Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATIONTM_SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 14.1—72.2 W No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. (f) Standard Air—Dry Coil—Outdoor START COMPONENTS(e) NO(Uses BAYKSKT263) (9) This value approximate.For more precise value see unit nameplate. INSULATION/SOUND BLANKET NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid COMPRESSOR HEAT NO 60 ft.For greater length consult refrigerant piping software Pub.No. 32-3312-0 ( denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 27.5—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.M 4275 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.64 OUTDOOR COIL—TYPE SPINE FINTM ROWS—F.P.I. 1-24 FACE AREA(SQ.Fr.) 24 TUBE SIZE(IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 8 LBS.,14 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 7/8 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SU BCOOLING 10O F DIMENSIONS H X W X D CRATED(IN.) 42 x 35.1 x 38.7 WEIGHT SHIPPING(LBS.) 246 NET(LBS.) 199 4A6H6036H-SUB-1A-EN 3 ,�l�KPr1 e'Aw �S i� H EATING & Al R CONDITIONING Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include: Centrifugal oil pump and low 11 VE Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,G60 Low Ambient Cooling galvanized steel and painted with a weather-resistant powder paint on all louvered panels and prepaint on all As manufactured,this system has a cooling capacity to other panels.Corrosion and weatherproof CMBP-G30 55°F.The addition of an evaporator defrost control base. permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and high pressure switch. High and automatic change over).Sub-base to match and low pressure controls are inherent to the thermostat and locking thermostat cover. compressor.A factory supplied liquid line drier is standard.Some models may require field installation. Evaporator Defrost Control — See Low Ambient Cooling. oi�� �S Intertek ShW4d4vde HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 American Standard Heating&Air Conditioning ^w,/4A6H6036H-SUB-1A-EN 01 Dec2014 I../Ingersoll Rand Supersedes(Now)