Loading...
halcyon-2020-full-line-brochure-04_Wed_Jul_7_2021_09-37-243 MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS FUJITSU GENERAL AMERICA, INC. 2 QUIETLY REVOLUTIONIZING ENERGY-EFFICIENT HOME COMFORT. 3 QUIETLY REVOLUTIONIZING ENERGY-EFFICIENT HOME COMFORT. TABLE OF CONTENTS FEATURES Mini-Splits Defined .........................................4 Individual Zoning ...........................................6 Comfort Solution ............................................8 Energy Efficient ..............................................9 Comfort & Convenience ................................10 Applications .................................................11 FGLair¬ App ..................................................12 WiFi Selection Guide .....................................13 XLTH Story ....................................................14 Feature Explanation .....................................15 System Feature Summary Table ...................16 MODEL LINEUP Indoor and Outdoor Model Table ..................18 SINGLE-ZONE MINI-SPLITS Wall Mount ...................................................20 Floor Mount ..................................................32 Compact Cassette .........................................34 Slim Duct ......................................................36 Medium Static Ducted ..................................38 Multi-Position Air Handler UNit ....................40 Universal Floor/Ceiling ..................................42 Ceiling Suspended ........................................42 Large Cassette ..............................................44 MULTI-ZONE MINI-SPLITS Overview ......................................................46 Wall Mount ...................................................50 Slim Duct ......................................................52 Compact Cassette .........................................54 Floor Mount ..................................................56 Multi-Zone (2-5 Zones) ................................58 XLTH Multi-Zone (2-4 Zones)........................60 Whole Home Solution...................................62 Allowable Combinations ...............................64 ACCESSORIES Compatibility Chart .......................................66 Airzone .........................................................68 Descriptions .................................................69 MISCELLANEOUS Line Set Length Chart - Single-Zone .............72 Line Set Length Chart - Multi-Zone ...............73 Model Nomenclature ....................................74 Warranty, Misc. Info .....................................75 4 FEATURES FUJITSU MINI-SPLITS: YEAR-ROUND, WHOLE-HOME OR BUSINESS ENERGY EFFICIENT HEATING AND COOLING Outdoor unit WHAT IS A MINI-SPLIT? Halcyon systems eliminate the need for a traditional central system and bulky ductwork by using small tubing that pumps refrigerant directly to discreet wall mounted or concealed units inside. Even more remarkable, this same system works in reverse during the cold season, absorbing heat energy from the outside air and moving it indoors to heat your home. The result? Efficient year-round cooling and heating, zoning flexibility, and optimum comfort in any climate. Available in numerous mix-and-match capacities and configurations, there’s a Halcyon mini-split system for even the most difficult to heat and cool areas. HOW DOES A MINI-SPLIT WORK? A heat pump uses electricity to pump refrigerant and transfer heat energy from one space to another. In the summer, heat energy from inside is absorbed and released outdoors. In the winter, heat energy is absorbed from the outside air and released inside. Indoor unit Refrigerant lines, electric, drain ...or Hidden Slim Duct units are mounted above a ceiling or in a framed enclosure below a ceiling, so only the grilles show for a clean look. They require minimal ductwork. Air supply grille Air return grille SLIM DUCT UNIT WALL MOUNT UNIT Unit Can Be Showcased... Wall mounted units eliminate the need for ductwork, mount high on a wall and deliver all of the cooling and heating needed. 5 An electric heater converts electricity directly to heat. For every kW of electricity used, 3,400 BTUH of heat are produced. Ironically, electric heaters are 100% efficient, however the ratio of power input to heat output* is only 1.0. Heat pumps are more efficient than many other forms of heating because heat pumps do not actually create heat - they just move it from one place to another. For example, a heat pump with a COP of 3.0 will produce three times the heat output per power input, compared to an electric resistance heater with a COP of 1.0. ELECTRIC HEATERS VERSUS HEAT PUMPS HEAT PUMPS PROVIDE HEAT WHEN IT IS COLD Fujitsu heat pumps absorb heat from the outdoors, and release it within your home, even on the coldest of days. We use efficient compressors to pump refrigerant via small copper tubing from outdoors to indoors. Inverter efficiency allows us to transfer heat at a ratio of 3 to 4 times higher compared to electric baseboard heat. BASIC HEAT PUMP CONFIGURATION Outdoor UnitIndoor Unitcompressor expansion valve Heat In Heat Out BASIC AIR CONDITIONER CONFIGURATION Outdoor UnitIndoor Unitcompressor expansion valve Heat Out Heat In AIR CONDITIONERS PROVIDE COOLING WHEN IT’S WARM Come spring and summer, simply reverse the process and put the same system into “cooling mode” and transfer heat from indoors to the outside. For many climates, the advanced technology that goes into these units creates a far more cost effective alternative to either gas or oil-fired units for heat, or a central ducted system for air conditioning. Fujitsu’s full mini-split line is comprised of heat pumps, which provide both heating and cooling. COP (Coefficient of Performance) - Rated BTU capacity divided by total kW input. 6 FEATURES INDIVIDUAL ZONING: PERSONALIZED WHOLE-HOME COMFORT MULTI-ZONE MINI SPLIT SYSTEMS Halcyon Systems are some of today’s most advanced forms of heating and air conditioning. One outdoor unit can operate up to 5 indoor units simultaneously. Fujitsu’s Systems are super quiet as well as highly energy efficient. • Each indoor unit can be operated independently via remote control • Choose from a variety of indoor unit styles • Provide both heating and cooling (not simultaneously) • High energy efficiencies • Quiet operation 3-zone system using outdoor unit AOU36RLXFZ1. 18, 24, 36,000 BTUh WALL MOUNTED They mount high on a wall, out of sight and do not require ductwork, increasing energy efficiency. • Quiet operation • Easy maintenance • High delivered efficiency means lower utility bills FEATURES 7 SLIM DUCT Installed horizontally above ceiling or vertically within wall space. They use less ductwork and remain very energy efficient. • Concealed and out of sight • Horizontal or Vertical Installation • Less ducts = higher efficiency FLOOR MOUNTED Floor mount systems are ideal for residential radiator replacements or any room with limited upper wall space, like a kitchen or sunroom. • Compact size fits easily under a standard window • Features twin fan design for improved heat delivery and help those cold feet. • Designer wireless remote control COMPACT CASSETTE Cassettes are extremely discreet, with only the grille showing in the ceiling. They use the latest fan technology to distribute the conditioned air evenly. • Wired or wireless remote control options • Powerful turbo fan operation • Fits into a standard 2’ x 2’ ceiling grid 8 FEATURES Thick black lines represent ducts of a central air system. Red lines represent mini- ducts of a Fujitsu Quad Zone Slim Duct System. DUCTLESS TECHNOLOGY Fujitsu systems are compact, meaning they install easily and won’t take up valuable closet space. Since mini-splits have little or no ducting, they forego energy losses typically associated with central forced-air systems. Duct losses in a central air system can easily account for more than 30% of energy consumption, especially if the ducts are not sealed tightly or installed in an unconditioned space such as an attic or crawlspace. CENTRAL AIR SYSTEM VERSUS FUJITSU QUAD ZONE A SOLUTION FOR ALL OF YOUR COMFORT NEEDS Bedroom 1Bedroom 1 72°F72°F Bedroom 2Bedroom 2 68°F68°F KitchenKitchen 74°F74°F Dining Dining RoomRoom70°F70°F OTHER APPLICATIONS The 30RLXEH is specially engineered for spaces which require constant cool temperatures year round, and/or rooms that hold a large number of people (meeting spaces, classrooms, conference rooms). WHOLE HOME OR BUSINESS COMFORT Fujitsu’s Halcyon systems provide home and business owners just the right amount of heating and cooling needed by installing 2 to 5 indoor units connected to one outdoor unit. Indoor units vary by size and style, each creating its own “zone” of comfort, allowing you to heat or cool individual rooms, hallways and open spaces. A YEAR ROUND SOLUTION Revolutionary Halcyon heat pumps provide both heating and cooling for year round comfort in most climates. A simple push of a button on the remote control allows you to switch from heating to cooling (or vice versa) automatically. Sta y warm Stay cool Stay comfortable 9 ENERGY EFFICIENT: THE SMART CHOICE IN COMFORT WHERE DOES MY MONEY GO? The high energy efficiencies of Halcyon systems slash utility bills by up to 30%. If your average annual utilities are $4,200, Fujitsu can save you up to $1,260 annually or $12,600 in 10 yrs!* *Savings may vary based on model selected, hours of operation and geographical location. Example given based on 33-SEER system versus 14-SEER system. REBATES To encourage customers to buy energy efficient products, many local utility companies offer significant rebates for the purchase of a ductless mini-split system. Go to Fujitsu’s web site to search for local rebates and consumer loans. We provide a listing of rebates and offerings on qualifying Fujitsu mini-splits by zip code. www.fujitsugeneral.com ENERGY STAR® QUALIFIED SYSTEMS If your HVAC equipment is more than 10 years old or not keeping your house comfortable, you should have it looked at by a professional HVAC contractor. If it is not performing efficiently or needs upgrading, consider replacing it with a unit that has earned ENERGY STAR®. Installed correctly, these high-efficiency heating and cooling units can save up to 30% on heating and cooling costs. Fujitsu has many systems that meet ENERGY STAR and Energy Star Most Efficient ratings in 2021. See the lineup chart on pages 18-19 for a full listing of all ENERGY STAR® qualified systems. As much as half of the energy used in your home goes to heating and cooling. So, making smart decisions about your home’s heating and air conditioning system can have a big effect on your utility bills — and your comfort. Energy Consumption %Conventional HPFujitsu HP50% 70% 100% HVAC Equipment Other Electronics Lighting Washer/ Dryer Dishwasher Refrigerator Water Heater Heating & Cooling 50% 8% 10% 6% 2% 5% 13% 7% Fujitsu saves up to 30% on your utility bill* 10 FEATURES COMFORT AND CONVENIENCE FLEXIBLE AND QUIET Mini splits offer flexibility because they can be suspended from a ceiling, mounted flush behind a drop ceiling, hung on a wall or floor-standing. Ductless heat pumps allow for a peaceful inside environment by enabling the contractor to install components like compressors and motors outdoors. CONSTANT COMFORT THROUGH INVERTER TECHNOLOGY Inverter technology is like cruise control for your heating or cooling system. Compressors only run as fast as they need to handle the cooling or heating demand. They can handle greater extremes in temperature, are smoother and more stable in operation, and precisely maintain the desired temperature through system modulation. Inverter Benefits • More heat at lower outdoor temperatures • Lower RPM = quieter operation • Maintains desired temperature • Up to 30% more efficient • Stable temperature USER FRIENDLY CONTROL Fujitsu is using ergonomics to expand the use of user friendly designs such as easy-to-read large LCD displays, easy-to- operate buttons, and displays with easily recognizable colors and icons. Our control systems provide greater convenience for both individual and centralized control with operability suitable for the application. Weakest Sound Heard Jet Engine at 100’ Whisper Quiet Library Normal Conversation from 3 - 5’ Power Tools 140 105 70 35 0 dB(A) Level Fujitsu Indoor Units 21~49 dB(A) Standard Wireless Remote for select systemsOptional Wired Remote UTY-RNRUZ Series Set Temp. Temp. Inverter System Set Temp. Temp. Conventional System 11 WHERE CAN MINI-SPLITS BE USED? Convenience stores Fast food chains Fire houses Police stations Bars Sunrooms and additions Warehouses Nursing homes Small offices Older homes New construction homes Schools Places of worship Hospitals and medical facilities Restaurants Hotels and motels ATM vestibules Historic Buildings JUST ABOUT ANY PLACE THAT REQUIRES COMFORT! APPLICATIONS 12 FEATURES WALL UNIT MEDIUM STATIC DUCTED MULTI-POSITION AIR HANDLER LARGE CASSETTE SLIM DUCT FLOOR UNIT CEILING CASSETTE Control up to 24 systems using a single free account. Individual AC name display Room temperature* ON/OFF button Temperature setting USER FRIENDLY INTERFACE User friendly screen display facilitates easy operation *Not available with UTY-TFNXZ2. MAIN FUNCTIONS • ON / OFF • Operation mode • Fan speed • Louver position • Set temperature control • Weekly timer • Minimum heat • Energy Saving Program • Error display • Email notification USER FRIENDLY INTERFACE User friendly screen display facilitates easy operation. FGLair¬ APP Control your home’s climate anytime, anywhere! Access control functions remotely from any smartphone or tablet. Set minimum heat Check operation Check operation On Off Change temperature Second house is worldwide trademark of FUJITSU GENERAL LIMITED. 13 FUJITSU HALCYON WIFI SELECTION GUIDE WIFI CONNECTABLE UNITS & MODULES FGLAir¬ Intesis AC Cloud Control¬ Built In Wi-Fi Interface Module Wi-Fi Interface Module IR Wireless Module Wired Module Wired Module ASUG 09/12/15 LZAS UTY-TFNXZ2 (Add-on) UTY-TFSXZ2 (Add-on) UTY-TFSXF1 (Add-on) FJ-IR-WIFI-1NA (Add-on) FJ-RC-WIFI-1NA (Add-on) FJ-AC-WIFI-1 (Add-on) WHICH APP DOES IT USE? FGLAir¬ Intesis AC Cloud Control¬ FGLAIR¬ APP FEATURES:Intesis AC Cloud Control¬ APP FEATURES: • On/Off • Louver/Swing Position • Change Mode • Weekly Timer • Change Temp Setpoint • Economy Setting • Fan Speed • Emailed Error Alerts NOTE: Room temperature display only available with LZAS1, LZAH1 units and UTY-TFSXZ2 or UTY- TFSXF1. • On/Off • Louver/Swing Position • Change Mode • Weekly Timer • Change Temp Setpoint • Fully Programmable • Fan Speed • Alarm Notifications • Room Temp (available on FJ-AC-WIFI-1) • Voice Control / IFTTT • Can be used in conjunction with Wired Controls App available on iOS and Android.App available on iOS and Android. Can also be run through a web browser. WHERE DOES IT MOUNT? Built into the LZAS On the wall next to IDU On the wall next to IDU Mounts inside unit case Up to 20’ away from IDU On the wall next to IDU On the wall next to IDU COMPATIBLE UNITS: WALL MOUNTS:WALL MOUNTS:WALL MOUNTS:WALL MOUNTS:WALL MOUNTS:WALL MOUNTS: ASUG 09/12/15LZAS ASU 7 / 9 / 12 / 15RLF11 ASUG 09/12LMAS ASU 7 / 9 / 12 / 15RLF1 ASU 7 / 9 / 12 / 15RLF11,3 ASU30RLE ASU 18 / 24RLF ASUH09 / 12LMAS^ASU 18 / 24RLF ASU 18 / 24RLF 3 ASUG09 / 12LMAS ASU 18 / 24RLB ASU 18 / 24RLB ASU 18 / 24RLB 3 ASUH09 / 12LMAS^ ASU 30 / 36RLXB ASU 30 / 36RLXB ASU 30 / 36RLXB 3 ASU30RLE CASSETTES:CASSETTES:CASSETTES:CASSETTES:CASSETTES: AUU 7 / 9 / 12 / 18RLF AUU 18 / 24 / 30 / 36 / 42 / 48RGLX AUU 7 / 9 / 12 / 18RLF AUU 7 / 9 / 12 / 18RLF AUU 18 / 24 / 30 / 36 / 42 / 48RGLX DUCTED:DUCTED:DUCTED:DUCTED:DUCTED: ARU 7 / 9 / 12 / 18 / 24RLF ARU 12 / 18 / 24 / 30 / 36 / 42 / 48RGLX ARU 7 / 9 / 12 / 18 / 24RLF 2 ARU 7 / 9 / 12 / 18 / 24RLF ARU 12 / 18 / 24 / 30 / 36 / 42 / 48RGLX FLOOR MOUNTS:AMUG 24 / 30 / 36 / 48 LMAS FLOOR MOUNTS:FLOOR MOUNTS:AMUG 24 / 30 / 36 / 48 LMAS AGU 9 / 12 / 15RLF AGU 9 / 12 / 15RLF AGU 9 / 12 / 15RLF 3 UTY-TFNXZ2 cannot be installed in conjunction with Wired Remote Controls. UNIVERSAL / CEILING:UNIVERSAL / CEILING: ABU 18 / 24RULX ABU 18 / 24RULX ABU36RSLX ABU36RSLX 1requires UTY-XCBXZ2 2requires UTY-LRHUM 3requires UTY-WIFI ^Coming Q3 2021 VOICE CONTROL FOR YOUR FUJITSU HALCYON SYSTEM USING AMAZON ECHO OR GOOGLE HOME All Fujitsu Halcyon systems can be voice controlled with Amazon Echo or Google Home speakers. IFTTT (IF THIS THEN THAT) Multi system integration through cloud services. Choose from a number of applets to operate your system based on Geo-fencing, Weather conditions, Google Calendar and more. 14 FEATURES BASE PAN HEATER • Equipped with a heater that prevents condensate from freezing • Contoured base design discharges melted water through drain holes. • Without a heater, freezing condensate can cause noise, damage to fan blades, condenser, and reduced system performance. HIGH PERFORMANCE HEATING Fujitsu XLTH units feature a high efficiency, multi-layer heat exchanger and high capacity compressor. This gives our XLTH heat pumps the ability to extract heat even at very low outdoor temperatures. All XLTH models offer superior heating performance down to -15°F outdoor temperatures. Drain OpeningsBase Heater EXTRA LOW TEMPERATURE HEATING - XLTH NOT ALL HEATING SYSTEMS ARE CREATED EQUAL Without the right technology, a system won’t work when it’s needed most. PROTECTION FROM WINTERS’ COLDEST TEMPERATURES When the temperature drops you don’t want to be left in the cold. It’s important to choose a heat pump system rated for the climate you live in. If your system doesn’t operate in severe conditions, it may not provide enough heat when needed most. Fujitsu’s line of mini-split heat pumps are available in different sizes, styles, and rated outdoor temperatures. The Extra Low Temperature Heating () Series features outdoor condensing units engineered to operate in temperatures down to -15°F. IMPROVED HEATING CAPACITY Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor.% of Heating CapacityAmbient Temperature (F°) 50 100 47 5 -15 Standard Series “H” Series Models Without the right technology, condensate freezes to the bottom of the unit and reduces its efficiency and heating output. METAL FAN GUARD While other models have a plastic fan guard, XLTH models use metal, which is most capable of withstanding the colder elements. Fujitsu XLTH systems do not have a low temperature lockout, continuing to heat even below -15°F as conditions allow. 15 FEATURE EXPLANATION ENERGY SAVING SEER Seasonal Energy Efficiency Rating. Used to express efficiency of an AC or Heat Pump. A higher rating means a more efficient system. HSPF Heating Seasonal Performance Factor, measures the efficiency of the heating portion of your heat pump. Economy Economy Mode Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating. Saving Energy Saver Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption. ESP Energy Saving Program (ESP) When the zone is unoccupied for 20 minutes, the ESP function is enabled to reduce energy consumption until occupied once again. Function is not available in multi-zone installations. ENERGY STAR® Qualified Qualified products and practices help you save money and reduce greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the U.S. Department of Energy. Minimum Heat Minimum Heat Mode Sets room temperature to 50°F, keeping temperatures above freezing and reducing power consumption. COMFORT Changeover Auto Auto Changeover (heating to cooling or vice-versa)* Automatically alternates between heating or cooling if the room temperature falls 4˚F below the set temperature when cooling or rises 4˚F above set temperature when heating. Adjust Auto Fan Mode System starts in high fan speed and automatically adjusts downward as room begins to reach set temperature. 4-Way Auto Louver: 4 Way Redirects airflow automatically with up/down and left/right motion. Up/Down Auto Louver: Up/Down Redirects airflow automatically with seven position up and down motion which can be set to auto swing. Restart Auto Restart Following a power failure, systems will automatically restart in the same operating mode as before, once power has been restored. Dry Dry Mode This mode gives priority to reducing the level of humidity in the room, in conjunction with lowering the temperature. Fresh Fresh Air Intake Outside air can be introduced by attaching field supplied flexible duct to fresh air knockouts. Low Noise Outdoor Unit Low Noise+ Limits compressor and fan speed during high speed operation for noise reduction purposes. Powerful Powerful Operation 20 minutes of continuous operation at maximum airflow and maximum compressor speed. Rapid cooling and heating makes the room comfortable quickly. Quiet Mode Quiet Mode (Indoor Unit) An extra quiet fan speed to make sure you are not disturbed. + Function is bypassed during defrost and at low speed operation. This feature may limit cooling/ heating capacity during high/low ambient conditions and increase energy consumption as system may need to operate longer due to reduced compressor speed.* Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. Areas with dissimilar conditioning requirements should be independently zoned. 66/2 Warranty 77/5 Warranty Standard Warranty Fujitsu systems come standard with either a 6 Year Compressor / 2 Year Parts warranty or a 7 Year Compressor / 5 Year Parts warranty. Extended Warranty Additional info on page 75. See full product warranty for details. CONVENIENCE 24 Hour 24 Hour Timer Allows for one on/off cycle during a 24 hour period. Sleep Sleep Timer Automatically adjusts the temperature while you sleep to make you more comfortable. Weekly Weekly Timer Allows you to set on/off time twice a day and a different on/off time by day. PERFORMANCE Apple Catechin Filter (polyphenol ingredient from apples) Dust, mold spores and microorganisms are absorbed onto the filter by static electricity and growth is inhibited. 3 - 12 month life expectancy. Cold Cold Air Prevention Indoor coil will warm prior to fan operating, preventing cold air during heating mode. 100% +5°F @ Expanded Heating Performance Delivers 100% of rated heating capacity at +5°F (-15°C). Ceiling High Ceiling Mode Temperature at the top of a high ceiling room may be warmer than the space occupied; this mode adjusts for this difference. Ion Ion Deodorizing Filter Deodorizes by decomposing absorbed odors using the oxidizing and reducing effects of ions generated by fine ceramic particles. 3 year life expectancy. Wash to restore surface action. Pump Down Pump Down Operation Collects all refrigerant in system back into the outdoor unit if the unit needs to be relocated. Eliminates costly refrigerant recovery procedures. Sensor Remote Temperature Sensor Room temperature sensor is located in optional wired remote control only. I/O 3rd Party Third Party Device Control Turns system on or off using a normally closed circuit. Interface with third party devices such as home automation. Cooling 0˚F 0°F Low Ambient Cooling Can operate in cooling mode with outdoor temperatures as low as 0°F. Cooling performance beyond published temperature ratings is not guaranteed. -5˚F Cooling -5°F Low Ambient Cooling Can operate in cooling mode with outdoor temperatures down to -5°F. Cooling performance beyond published temperature ratings is not guaranteed. INSTALLATION Heater Base Pan Heater Prevents condensate from freezing on the outdoor unit. Blue Fin Blue Fin Coating Blue Fin treatment to the outdoor unit’s heat exchanger improves corrosion resistance. Hydro Fin Hydro Fin Coating Clear hydrophylic treatment added to the outdoor unit’s heat exchanger improves corrosion resistance. Branch Branch Duct Capable Systems are capable of attaching field-supplied branch ducts providing up to 38% of the cooling up to 16 feet away. Pump Built-In Condensate Pump Integrated into the indoor unit. 16 Daisy Daisy Chain Ability to connect up to 16 identical style indoor units to one wired remote. 164+ ft Piping Long Piping Length Long piping lengths between equipment offers flexible outdoor unit location options. Slender Slender Fit Cassette body can be moved downward into the room 1-3/8” to accommodate limited ceiling space. 16 FEATURES SINGLE-ZONE HEAT PUMPS SINGLE-ZONE HEAT PUMPS MULTI-ZONEHEAT PUMPS p Available only with optional wired remote control.  Available only with optional wired remote controller and optional Interface Kit.  Available only with optional part UTY-SHZXC  Available only with optional wireless remote control. ¡ Available only with optional Interface Kit. Operation monitoring and On/Off control only.  Available only with optional louver grille UTD-GXS(A/B/C)-W or UTD-GXT(A/B/C)-W  Available only with optional Fresh Air Intake Kit. * See bottom of page 58 and page 60 for qualifying combinations. ** Operation limited to on/off, set point, and mode. Using third party control devices eliminates inverter capabilities. ^ SEER and HSPF ratings depend on combination of indoor units and outdoor unit selected. + Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 1 Standard warranty is 5 year Parts / 7 year Compressor. 12 year Compressor/Parts warranty applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. WALL MOUNT FLOOR MOUNT COMPACT CASSETTE SLIM DUCT MEDIUM STATIC DUCTED MULTI- POSITION AIR HANDLER UNIVERSAL FLOOR / CEILING LARGE CASSETTE 9RL209LMAS109LMAH109LZAS109LZAH112RL212LMAS112LMAH112LZAS112LZAH115LZAS115LZAH118RLB18RLXFW118RLXFWH24RLB24RLXFW124RLXFWH30RLXEH30RLXB36RLXB9RLFF9RLFFH12RLFF12RLFFH15RLFF15RLFFH9RLFCC12RLFCC18RLFCC9RLFCD12RLFCD18RLFCD12RGLXD18RGLXD24RGLXD30RGLXD36RGLXD42RGLXD48RGLXD24RGLXM30RGLXM36LMAS148LMAS118RULX24RULX36RSLX18RGLXC24RGLXC30RGLXC36RGLXC42RGLXC48RGLXCCompact Wall(RLF1: 7-15k BTU)Large Wall (RLF: 18, 24k BTU)Slim DuctCassetteFloor MountEconomy Mode Economy l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Energy Saver Saving p p p Energy Saving Pgm (ESP) ESP l l l l l l l  ENERGY STAR® Qualified l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l* Minimum Heat Mode Minimum Heat l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Auto Changeover Changeover Auto l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l+l+l+l+l Auto Fan Mode Adjust l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Auto Louver: 4 Way 4-Way l l l l l l l l l l l l l l l l l l l Auto Louver: Up/ Down Up/Down l l l l l l l l l l l l l l l l l l l l l l l l Auto Restart Restart l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Dry Mode Dry l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Fresh Air Intake Fresh l l l l l l l l l l l l l l l l l l l l  Outdoor Unit Low Noise Low Noise l l l l l l l l l l l l l Powerful Operation Powerful l l l l l l l l l l l l l l l l l l l l Quiet Mode (Indoor Unit) Quiet Mode l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l 24 Hour Timer 24 Hour l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Sleep Timer Sleep l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Weekly Timer Weekly p p l l p p l l l l p p l p p l l p p p p p p p p l l l l l l p p p p p p p p p p p p p p p p p p p p p p l l p Apple Catechin Filter l l l l l l l l l l l l l l l l l l l l l l l l l l l l Cold Air Prevention Cold l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Expanded Htg. Performance 100% +5°F@ l l l l l l l l l l l l l l l l l l l l l High Ceiling Mode Ceiling l l l l l l l l l l l l l Ion Deodorizing Filter Ion l l l l l l l l l l l l l l l l l l l l l l l l l l l l Pump Down Operation Pump Down l l l l l l l l l l l l l l l l l l l l l Remote Temp. Sensor Sensor  p p p p p p p p p p p p p p p l l l l l l p p p p p p p p p p p p p p p p p p p p p l l p **Third Party Device Control I/O 3rd Party ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 0° Low Ambient Clg. Cooling 0˚F l l l l l l l l l l l l l l l l l -5° Low Ambient Clg. -5˚F Cooling l l l l l l l l l l l l l l l l l l l Base Pan Heater Heater l l l l l l l l l l l Blue Fin Coil Protection Blue Fin l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Hydro Fin Hydro Fin l l l l l l l l l l l l l l l l l l l l l l l l l Branch Duct Capable Branch l l l l l l Built-In Condensate Pump Pump l l l l l l l l l l l l l l l l l l l l l Daisy Chain 16Daisy p p p p p p p p p p p p p p p l l l l l l l l l l l l l l l l l l l l l l l l l l p l l p Long Piping Length (164’+) 164+ ft Piping l l l l l l l l l l l l l l l l l l l l l l l l l l Slender Fit Slender l l l l l l Warranty: 6 Yr Comp / 2 Yr Parts 66/2 Warranty l l l Warranty: up to 12 Yr Comp / Parts 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SYSTEM FEATURE SUMMARY 17 SINGLE-ZONE HEAT PUMPS SINGLE-ZONE HEAT PUMPS MULTI-ZONEHEAT PUMPS p Available only with optional wired remote control.  Available only with optional wired remote controller and optional Interface Kit.  Available only with optional part UTY-SHZXC  Available only with optional wireless remote control. ¡ Available only with optional Interface Kit. Operation monitoring and On/Off control only.  Available only with optional louver grille UTD-GXS(A/B/C)-W or UTD-GXT(A/B/C)-W  Available only with optional Fresh Air Intake Kit. * See bottom of page 58 and page 60 for qualifying combinations. ** Operation limited to on/off, set point, and mode. Using third party control devices eliminates inverter capabilities. ^ SEER and HSPF ratings depend on combination of indoor units and outdoor unit selected. + Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 1 Standard warranty is 5 year Parts / 7 year Compressor. 12 year Compressor/Parts warranty applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. WALL MOUNTFLOOR MOUNTCOMPACT CASSETTE SLIM DUCT MEDIUM STATIC DUCTED MULTI- POSITION AIR HANDLER UNIVERSAL FLOOR / CEILING LARGE CASSETTE 9RL209LMAS109LMAH109LZAS109LZAH112RL212LMAS112LMAH112LZAS112LZAH115LZAS115LZAH118RLB18RLXFW118RLXFWH24RLB24RLXFW124RLXFWH30RLXEH30RLXB36RLXB9RLFF9RLFFH12RLFF12RLFFH15RLFF15RLFFH9RLFCC12RLFCC18RLFCC9RLFCD12RLFCD18RLFCD12RGLXD18RGLXD24RGLXD30RGLXD36RGLXD42RGLXD48RGLXD24RGLXM30RGLXM36LMAS148LMAS118RULX24RULX36RSLX18RGLXC24RGLXC30RGLXC36RGLXC42RGLXC48RGLXCCompact Wall(RLF1: 7-15k BTU)Large Wall (RLF: 18, 24k BTU)Slim DuctCassetteFloor MountEconomy Mode Economylllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l Energy Saver Saving p p p Energy Saving Pgm (ESP) ESPlllllll  ENERGY STAR® Qualified llllllllllllllllllllllllll l l l l l l* Minimum Heat Mode Minimum Heatllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l Auto Changeover Changeover Autolllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l+l+l+l+l Auto Fan Mode Adjustlllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l l l l Auto Louver: 4 Way 4-Waylllllllllllllll l l l l Auto Louver: Up/ Down Up/Downllllllllllllllll l l l l l l l l Auto Restart Restartlllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l l l l Dry Mode Drylllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l l l l Fresh Air Intake Freshlll l l l l l l l l l l l l l l l l l  Outdoor Unit Low Noise Low Noiselllllll l l l l l l Powerful Operation Powerful lllllllllllllllllll l Quiet Mode (Indoor Unit) Quiet Modelllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l 24 Hour Timer 24 Hourllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l l Sleep Timer Sleeplllllllllllllllllllllllllll l l l l l l Weekly Timer Weeklyppllppllllpplppllppppppppllllll p p p p p p p p p p p p p p p p p p p p p p l l p Apple Catechin Filter lllllllllllllllllllllllll l l l Cold Air Prevention Coldlllllllllllllllllllllllllllllllll l l l l l l l l l l l l l l l l l l l l l l l l l Expanded Htg. Performance 100% +5°F@llllllllllllllllllll l High Ceiling Mode Ceilinglll l l l l l l l l l l Ion Deodorizing Filter Ionlllllllllllllllllllllllll l l l Pump Down Operation Pump Downl l l l l l l l l l l l l l l l l l l l l Remote Temp. Sensor Sensor pppppppppppppppllllll p p p p p p p p p p p p p p p p p p p p p l l p **Third Party Device Control I/O 3rd Party¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 0° Low Ambient Clg. Cooling 0˚F l l l l l l l l l l l l l l l l l -5° Low Ambient Clg. -5˚F Coolinglllll l l l l l l l l l l l l l l Base Pan Heater Heaterlllllllllll Blue Fin Coil Protection Blue Finllllllll l l l l l l l l l l l l l l l l l l l l l l Hydro Fin Hydro Fin llllllllllllllllllllll l l l Branch Duct Capable Branch l l l l l l Built-In Condensate Pump Pumpllllll l l l l l l l l l l l l l l l Daisy Chain 16Daisypppppppppppppppllllll l l l l l l l l l l l l l l l l l l l l p l l p Long Piping Length (164’+) 164+ ft Pipinglllllll l l l l l l l l l l l l l l l l l l l Slender Fit Slender l l l l l l Warranty: 6 Yr Comp / 2 Yr Parts 66/2 Warranty l l l Warranty: up to 12 Yr Comp / Parts 111111111111111111111111111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 18 MODEL LINEUP SINGLE-ZONE AND MULTI-ZONE SYSTEMS LINEUP BTU 7,000 9,000 12,000 15,000 18,000 24,000 Compact Wall Mount ASU7RLF1 ASU9RLF1 ASU12RLF1 ASU15RLF1 Large Wall Mount ASU18RLF ASU24RLF Slim Duct ARU7RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF Compact Cassette AUU7RLF AUU9RLF AUU12RLF AUU18RLF Floor Mount AGU9RLF AGU12RLF AGU15RLF : Energy Star Qualified : Minimum Ambient Cooling Temperature : Minimum Ambient Heating Temperature SINGLE ZONE WALL MOUNTED MINI-SPLITS BTU 9,000 12,000 15,000 18,000 24,000 30,000 36,000 42,000 48,000 BESTWall Mount Highest Efficiency  14°F -5°F ASUG09LZAS / AOUG09LZAS1  14°F -5°F ASUG12LZAS / AOUG12LZAS1  14°F -5°F ASUG15LZAS / AOUG15LZAS1 Wall Mount  14°F -15°F ASUG09LZAS / AOUG09LZAH1  14°F -15°F ASUG12LZAS / AOUG12LZAH1  14°F -15°F ASUG15LZAS / AOUG15LZAH1  14°F -15°F ASU18RLF / AOU18RLXFWH  -5°F -15°F ASU24RLF / AOU24RLXFWH  -5°F -15°F ASU30RLE / AOU30RLXEHExtra Low Temp Heating BETTERWall Mount High Efficiency  14°F 5°F ASUG09LMAS / AOUG09LMAS1  14°F 5°F ASUG12LMAS / AOUG12LMAS1  -5°F -5°F ASU18RLF / AOU18RLXFW1  -5°F -5°F ASU24RLF / AOU24RLXFW1 Wall Mount  14°F -15°F ASUH09LMAS / AOUH09LMAH1  14°F -15°F ASUH12LMAS / AOUH12LMAH1Extra Low Temp Heating GOODWall Mount Entry Level 15°F 15°F ASU9RL2 / AOU9RL2 15°F 15°F ASU12RL2 / AOU12RL2  14°F 5°F ASU18RLB / AOU18RLB 14°F 5°F ASU24RLB / AOU24RLB 14°F 5°F ASU30RLXB / AOU30RLXB 14°F 5°F ASU36RLXB / AOU36RLXB SINGLE ZONE NON-WALL MOUNTED MINI-SPLITS Floor Mount Highest Efficiency  14°F -5°F AGU9RLF / AOU9RLFF  14°F -5°F AGU12RLF / AOU12RLFF  14°F -5°F AGU15RLF / AOU15RLFF Floor Mount Extra Low Temp Heating  14°F -15°F AGU9RLF / AOU9RLFFH  14°F -15°F AGU12RLF / AOU12RLFFH  14°F -15°F AGU15RLF / AOU15RLFFH Compact Cassette  14°F -5°F AUU9RLF / AOU9RLFC  14°F -5°F AUU12RLF / AOU12RLFC 14°F -5°F AUU18RLF / AOU18RLFC Slim Duct Horizontal/Vertical  14°F -5°F ARU9RLF / AOU9RLFC  14°F -5°F ARU12RLF / AOU12RLFC 14°F -5°F ARU18RLF / AOU18RLFC Infinite Comfort SeriesMedium-Static Ducted  14°F -5°F ARU12RGLX / AOU12RLFC  -5°F -5°F ARU18RGLX / AOU18RGLX  -5°F -5°F ARU24RGLX / AOU24RGLX -5°F -5°F ARU30RGLX / AOU30RGLX -5°F -5°F ARU36RGLX / AOU36RGLX -5°F -5°F ARU42RGLX / AOU42RGLX -5°F -5°F ARU48RGLX / AOU48RGLX Multi-Position Air Handler -5°F -5°F AMUG24LMAS / AOU24RGLX -5°F -5°F AMUG30LMAS / AOU30RGLX 14°F -5°F AMUG36LMAS / AOUG36LMAS1 14°F -5°F AMUG48LMAS / AOUG48LMAS1 Universal Mount / Ceiling Only 0°F 14°F ABU18RULX / AOU18RLX 0°F 14°F ABU24RULX / AOU24RLX 0°F 14°F ABU36RSLX / AOU36RLX Large Cassette Circular Flow  -5°F -5°F AUU18RGLX / AOU18RGLX  -5°F -5°F AUU24RGLX / AOU24RGLX -5°F -5°F AUU30RGLX / AOU30RGLX -5°F -5°F AUU36RGLX / AOU36RGLX -5°F -5°F AUU42RGLX / AOU42RGLX -5°F -5°F AUU48RGLX / AOU48RGLX MULTI ZONE DUCTLESS HEAT PUMPS - INDOOR UNITS MULTI ZONE DUCTLESS HEAT PUMPS- OUTDOOR UNITS COMING Q3 21 19 : Energy Star Qualified : Minimum Ambient Cooling Temperature : Minimum Ambient Heating Temperature SINGLE ZONE WALL MOUNTED MINI-SPLITS BTU9,00012,00015,00018,000 24,000 30,000 36,000 42,000 48,000 BESTWall Mount Highest Efficiency 14°F-5°F ASUG09LZAS / AOUG09LZAS1  14°F-5°F ASUG12LZAS / AOUG12LZAS1  14°F-5°F ASUG15LZAS / AOUG15LZAS1 Wall Mount  14°F-15°F ASUG09LZAS / AOUG09LZAH1  14°F-15°F ASUG12LZAS / AOUG12LZAH1  14°F-15°F ASUG15LZAS / AOUG15LZAH1  14°F-15°F ASU18RLF / AOU18RLXFWH  -5°F -15°F ASU24RLF / AOU24RLXFWH  -5°F -15°F ASU30RLE / AOU30RLXEHExtra Low Temp Heating BETTERWall Mount High Efficiency 14°F5°F ASUG09LMAS / AOUG09LMAS1  14°F5°F ASUG12LMAS / AOUG12LMAS1  -5°F-5°F ASU18RLF / AOU18RLXFW1  -5°F -5°F ASU24RLF / AOU24RLXFW1 Wall Mount  14°F-15°F ASUH09LMAS / AOUH09LMAH1  14°F-15°F ASUH12LMAS / AOUH12LMAH1Extra Low Temp Heating GOODWall Mount Entry Level 15°F15°F ASU9RL2 / AOU9RL2 15°F15°F ASU12RL2 / AOU12RL2  14°F5°F ASU18RLB / AOU18RLB 14°F 5°F ASU24RLB / AOU24RLB 14°F 5°F ASU30RLXB / AOU30RLXB 14°F 5°F ASU36RLXB / AOU36RLXB SINGLE ZONE NON-WALL MOUNTED MINI-SPLITS Floor Mount Highest Efficiency 14°F-5°F AGU9RLF / AOU9RLFF  14°F-5°F AGU12RLF / AOU12RLFF  14°F-5°F AGU15RLF / AOU15RLFF Floor Mount Extra Low Temp Heating  14°F-15°F AGU9RLF / AOU9RLFFH  14°F-15°F AGU12RLF / AOU12RLFFH  14°F-15°F AGU15RLF / AOU15RLFFH Compact Cassette  14°F-5°F AUU9RLF / AOU9RLFC  14°F-5°F AUU12RLF / AOU12RLFC 14°F-5°F AUU18RLF / AOU18RLFC Slim Duct Horizontal/Vertical 14°F-5°F ARU9RLF / AOU9RLFC  14°F-5°F ARU12RLF / AOU12RLFC 14°F-5°F ARU18RLF / AOU18RLFC Infinite Comfort SeriesMedium-Static Ducted 14°F-5°F ARU12RGLX / AOU12RLFC  -5°F-5°F ARU18RGLX / AOU18RGLX  -5°F -5°F ARU24RGLX / AOU24RGLX -5°F -5°F ARU30RGLX / AOU30RGLX -5°F -5°F ARU36RGLX / AOU36RGLX -5°F -5°F ARU42RGLX / AOU42RGLX -5°F -5°F ARU48RGLX / AOU48RGLX Multi-Position Air Handler -5°F -5°F AMUG24LMAS / AOU24RGLX -5°F -5°F AMUG30LMAS / AOU30RGLX 14°F -5°F AMUG36LMAS / AOUG36LMAS1 14°F -5°F AMUG48LMAS / AOUG48LMAS1 Universal Mount / Ceiling Only 0°F14°F ABU18RULX / AOU18RLX 0°F 14°F ABU24RULX / AOU24RLX 0°F 14°F ABU36RSLX / AOU36RLX Large Cassette Circular Flow -5°F-5°F AUU18RGLX / AOU18RGLX  -5°F -5°F AUU24RGLX / AOU24RGLX -5°F -5°F AUU30RGLX / AOU30RGLX -5°F -5°F AUU36RGLX / AOU36RGLX -5°F -5°F AUU42RGLX / AOU42RGLX -5°F -5°F AUU48RGLX / AOU48RGLX MULTI ZONE DUCTLESS HEAT PUMPS - INDOOR UNITS MULTI ZONE DUCTLESS HEAT PUMPS- OUTDOOR UNITS BTU 18,000 (2 Indoor Units)24,000 (2 - 3 Indoor Units)36,000 (2 - 4 Indoor Units)45,000 (2 - 5 Indoor Units)BEST + 14°F -15°F AOU18RLXFZH + 14°F -15°F AOU24RLXFZH + 14°F -15°F AOU36RLXFZH BETTER + 14°F 5°F AOU18RLXFZ + 14°F 5°F AOU24RLXFZ 14°F 5°F AOU36RLXFZ1 14°F 5°F AOU45RLXFZ + For ENERGY STAR® qualified combinations, see page 58 and page 60. 20 FEATURES · Extensive lineup from 9,000 to 48,000 BTU · 3 2 different systems available in 7 indoor unit styles · Energy efficient systems with SEER ratings as high as 33.1 and HSPF as high as 14.2 · 29 ENERGY STAR® qualified systems · Inverter Technology is used in all systems · All systems feature environmentally friendly R410A refrigerant · Quiet operation with indoor units as low as 19dB(A) and outdoor units as low as 46dB(A) SINGLE-ZONE MINI-SPLIT SYSTEMS Making the hottest places cool and the coolest places more comfortable ENERGY SAVING PROGRAM (ESP) FUNCTION With the ESP function, the ASUG*LZAS system actively monitors occupancy and adjusts system settings accordingly to achieve optimum energy savings. Once the system detects an occupant, the settings are reverted to the user defined settings in order to maintain comfort. HIGH PERFORMANCE HEATING The LZAS1 model can operate down to -5°F. The LZAH1 can operate down to -15°F. See the full story on page 14. 9, 12, 15,000 BTUh WALL MOUNT HEAT PUMPS Wi-Fi Enabled BUILT-IN WI-FI Remotely operate your heating and cooling system using a smartphone as a remote control. Details on page 12 . OPTIONAL ACCESSORIES Wired Remote Controller .............................UTY-RNRUZ Series Simple Remote Controller ......................UTY-RSRY / UTY-RHRY Communication Kit ..............................................UTY-TWRXZ2 External Input and Output PCB ..............................UTY-XCSXZ2 Thermostat Converter ................................................UTY-TTRX 1 Economy ESP Minimum Heat Changeover Auto Adjust 4-Way Restart Dry Low Noise Powerful Quiet Mode 24 Hour Sleep Weekly Cold 100% +5°F @ Ion Sensor 2 I/O 3rd Party 3 Heater 4 16 Daisy 2 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wired Remote Control and optional interface kit. 3 Available only with optional interface kit. Operation monitoring and On/Off control only. 4 XLTH models only SINGLE-ZONE MINI-SPLITS 21 09LZAS1 12LZAS1 15LZAS1 09LZAH1 12LZAH1 15LZAH1 Performance Nominal Cooling BTUh 9,000 12,000 14,500 9,000 12,000 14,500 Min.-Max. Cooling BTUh 3,100~12,000 3,100~13,600 3,100~18,400 3,100~12,000 3,100~13,600 3,100~18,400 Nominal Heating BTUh 12,000 16,000 18,000 12,000 16,000 18,000 Min.-Max. Heating BTUh 3,100~22,000 3,100~22,100 3,100~23,900 3,100~22,000 3,100~22,100 3,100~23,900 SEER 33.1 29.4 25.3 33.1 29.4 25.3 HSPF 14.2 14.0 13.4 14.0 13.8 13.3 EER 18.0 15.2 13.9 18.0 15.2 13.9 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46) Heating Operating Range °F (°C) -5~75 (-21~24)-5~75 (-21~24)-5~75 (-21~24)-15~75 (-26~24)-15~75 (-26~24)-15~75 (-26~24) Moisture Removal Pt./h (l/h)2.5 (1.2)2.7 (1.3)4.0 (1.9)2.5 (1.2)2.7 (1.3)4.0 (1.9) Max Htg % of Nominal Capacity at +5˚F (-15˚C)*171%138%140%171%138%140% Max Htg % of Nominal Capacity at -5˚F (-21˚C)*156%125%124%156%125%124% Max Htg % of Nominal Capacity at -15˚F (-26˚C)*------123%98%109% Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)542 (920)542 (920)583 (990)542 (920)542 (920)583 (990) Medium CFM (m3/h)406 (690)406 (690)459 (780)406 (690)406 (690)459 (780) Low CFM (m3/h)312 (530)312 (530)312 (530)312 (530)312 (530)312 (530) Quiet CFM (m3/h)206 (350)206 (350)241 (410)206 (350)206 (350)241 (410) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Level (Clg/Htg): Hi dB(A)43/43 43/43 45/45 43/43 43/43 45/45 Medium dB(A)37/36 37/36 40/39 37/36 37/36 40/39 Low dB(A)31/31 31/31 32/32 31/31 31/31 32/32 Quiet dB(A)23/23 23/23 26/26 23/23 23/23 26/26 Outdoor Level Clg/Htg dB(A)46/47 47/47 49/50 46/47 47/47 49/50 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 15 20 15 15 20 Current Rated/Max: Cooling Amps 2.5/9.4 3.8/9.4 4.8/9.9 2.5/9.4 3.8/9.4 4.8/9.9 Current Rated/Max: Heating Amps 3.3/10.9 4.7/10.9 5.2/13.4 3.3/11.9 4.7/11.9 5.2/14.4 Power Use Rated/Max: Cooling kW 0.50/0.85 0.79/0.99 1.04/1.56 0.50/0.85 0.79/0.99 1.04/1.56 Power Use Rated/Max: Heating kW 0.66/1.93 1.01/1.94 1.15/2.19 0.66/1.93 1.01/1.94 1.15/2.19 Size & Weight Net Weight lbs. (kg) 29 (13)84 (38)29 (13) 84 (38)29 (13) 86 (39)29 (13)86 (39) 29 (13)86 (39)29 (13)88 (40) Dimensions: Height Inch 11 24-7/8 11 24-7/8 11 24-7/8 11 24-7/8 11 24-7/8 11 24-7/8 mm 280 632 280 632 280 632 280 632 280 632 280 632 Width Inch 38-9/16 31-7/16 38-9/16 31-7/16 38-9/16 31-7/16 38-9/16 31-7/16 38-9/16 31-7/16 38-9/16 31-7/16 mm 980 799 980 799 980 799 980 799 980 799 980 799 Depth Inch 9-7/16 11-7/16 9-7/16 11-7/16 9-7/16 11-7/16 9-7/16 11-7/16 9-7/16 11-7/16 9-7/16 11-7/16 mm 240 290 240 290 240 290 240 290 240 290 240 290 Refrigerant R410A R410A R410A R410A R410A R410A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Washable Washable Minimum Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5)16 (5)16 (5) Maximum Lineset Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) Max. Vertical Diff.Ft (m)49 (15)49 (15)49 (15)49 (15)49 (15)49 (15) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 * Based on model # capacity class (e.g. 09LZAS1 based on 9,000 BTUh) @ 70°F indoor setpoint. Refer to the Design & Technical Manual for expanded heating capacity data.IndoorASUG09LZASOutdoorAOUG09LZAS1IndoorASUG12LZASOutdoorAOUG12LZAS1IndoorASUG15LZASOutdoorAOUG15LZAS1IndoorASUG09LZASOutdoorAOUG09LZAH1IndoorASUG12LZASOutdoorAOUG12LZAH1IndoorASUG15LZASOutdoorAOUG15LZAH1 Note: Figures are based on 230 Volts. SYSTEMS 09LZAS1, 12LZAS1, 15LZAS1 HIGH HEAT SYSTEMS 09LZAH1, 12LZAH1, 15LZAH1 UP TO 33.1 SEER MULTI-ZONE MINI-SPLITS 22 9 AND 12,000 BTUh WALL MOUNT HEAT PUMPS BUILT IN FILTRATION LONG-LIFE ION DEODORIZATION FILTER The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine particle ceramic. The filter can be used for approximately 3 years if it is washed with water when dirty to restore its surface action. APPLE-CATECHIN FILTER Dust, mold spores and micro-organisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. Filter lasts 3-12 months. Ion SINGLE-ZONE MINI-SPLITS 1 Economy Minimum Heat Changeover Auto Adjust Up/Down Restart Dry Powerful Quiet Mode 24 Hour Sleep We ekly 2 Cold Ion Sensor 3 I/O 3rd Party 4 16 Daisy 3 Wi-Fi Capable 5 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wired remote control. 3 Available only with optional wired remote control and optional interface kit. 4 Available only with optional interface kit. Operation monitoring and On/Off control only. 5 See page 13 for details. Ion Deodorization Filter Apple-catechin Filter Air Filter EXTRA LOW TEMP HEATING - COMING Q3 21 LMAH1 models operate efficiently and provide high heating capacity down to -15°F, ideal for cold climate applications. See the full story on page 14. OPTIONAL ACCESSORIES Wired Remote Controller .............................UTY-RNRUZ Series Simple Remote Controller ......................UTY-RSRY / UTY-RHRY Wireless LAN Interface ..........................................UTY-TXSFX1 Thermostat Converter ................................................UTY-TTRX External Input and Output PCB ..............................UTY-XCSXZ2 External Connect Kit ............................................UTY-XWZXZ5 Communication Kit ..............................................UTY-TWRXZ2 STRENGTH AND RELIABILITY Improved reliability is achieved by using HCRC (High Corrosion Resistant Copper) for the indoor unit heat exchanger. Testing has proven to show that HCRC is resilient and stronger than the standard and OFC (Oxygen Free Copper) when exposed to corrosive environments. 23 UP TO 26.5 SEER SYSTEMS 09LMAS1, 12LMAS1 COMING Q3 21 - HIGH HEAT SYSTEMS 09LMAH1, 12LMAH1 09LMAS1 12LMAS1 09LMAH1 12LMAH1 Performance Nominal Cooling BTUh 9,000 12,000 9000 12000 Min.-Max. Cooling BTUh 3,400-10,900 3,400~13,300 3,400—11,500 3,400—13,300 Nominal Heating BTUh 12,000 16,000 12000 16000 Min.-Max. Heating BTUh 2,800-15,000 2,800~19,100 2,800—16,000 2,800—19,100 SEER 26.5 23.0 26.5 23 HSPF 13.0 12.5 13 12.5 EER 14.3 12.5 15.4 12.5 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14 to 115 (-10 to 46)14 to 115 (-10 to 46) Heating Operating Range °F (°C) 5~75 (-15~24)5~75 (-15~24)-15 to 75 (-26 to 24)-15 to 75 (-26 to 24) Moisture Removal Pt./h (l/h)2.7 (1.3)3.8 (1.8)2.7 (1.3)3.8 (1.8) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)453 (770)453 (770)453 (770)453 (770) Medium CFM (m3/h)353 (600)353 (600)353 (600)353 (600) Low CFM (m3/h)265 (450)265 (450)265 (450)265 (450) Quiet CFM (m3/h)147 (250)147 (250)147 (250)147 (250) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)43/43 43/43 43/43 43/43 Medium dB(A)36/38 36/38 36/38 36/38 Low dB(A)30/33 30/33 30/33 30/33 Quiet dB(A)19/21 19/21 19/21 19/21 Outdoor Sound Level Clg/Htg dB(A)46/48 49/51 46/48 49/51 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 15 15 15 Current Rated/Max: Cooling Amps 3.1/6.4 4.7/6.9 3/6.9 4.7/6.9 Current Rated: Heating Amps 4.0/7.9 6.0/9.4 3.9/9.4 6/9.4 Power Use Rated/Max: Cooling kW 0.63/0.92 0.96/1.27 0.585/1.27 0.96/1.27 Power Use Rated/Max: Heating kW 0.84/1.61 1.28/1.67 0.79/1.67 1.28/1.67 Size & Weight Net Weight lbs. (kg) 22 (10)68 (31)22 (10)71 (32)22 (10)73 (33)22 (10)73 (33) Dimensions: Height Inch 10-5/8 21-5/16 10-5/8 21-5/16 10-5/8 21- 5/16 10-5/8 21- 5/16 mm 270 542 270 542 270 542 270 542 Width Inch 32-13/16 31-7/16 32-13/16 31-7/16 32-13/16 31- 7/16 32-13/16 31- 7/16 mm 834 799 834 799 834 799 834 799 Depth Inch 8-3/4 11-7/16 8-3/4 11-7/16 8-3/4 11- 7/16 8-3/4 11- 7/16 mm 222 290 222 290 222 290 222 290 Refrigerant R410A R410A R410A R410A Additional Data Air Direction: Horizontal Manual Manual Manual Manual Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washabale Washabale Minimum Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5) Maximum Lineset Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) Max. Vertical Diff.Ft (m)49 (15)49 (15)49 (15)49 (15) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 IndoorASUG09LMASOutdoorAOUG09LMAS1IndoorASUG12LMASOutdoorAOUG12LMAS1Indoor ASUH09LMASOutdoorAOUH09LMAH1IndoorASUH12LMASOutdoorAOUH12LMAH1Note: Figures are based on 230 Volts. 24 SINGLE-ZONE MINI-SPLITS HIGH PERFORMANCE HEATING CAPACITY Stay comfortable at low ambient temperatures! The RLXFW1 systems can deliver 100% or more of rated heating capacity at 5°F (-15°C) and operates down to -5°F (-21°C). The RLXFWH model can operate down to -15°F. See the full story on page 14. OPTIONAL ACCESSORIES Wired Remote Control ..........................................UTY-RVNUM Wired Remote Control ..........................................UTY-RNNUM Simple Remote Control ..........................................UTY-RSNUM Dry Contact Wire Kit ................................................UTY-XWZX Wi-Fi Interface Module .........................................UTY-TFNXZ2 18 AND 24,000 BTUh WALL MOUNT HEAT PUMPS 1 Economy Minimum Heat Changeover Auto Adjust 4-Way Restart Dry Quiet Mode 24 Hour 2 Sleep Weekly 3 Cold 100% +5°F @ Ion Sensor 4 I/O 3rd Party 5 -5˚F Cooling Heater 6 Blue Fin 16 Daisy 4 164+ ft Piping Wi-Fi Capable 7 80% 100% 120% 140% 160% 180% 24K18K 50°47°41°32°23°14°5°-5° Outdoor temperature (°F)Maximum heating capacityBased on 70° indoor setpoint 80% 100% 120% 140% 160% 180% 24KH18KH 50º47º41º32º23º14º5º-5º-15º Outdoor temperature (°F)Maximum heating capacityBased on 70° indoor setpoint 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 RLXFW1 systems only. 3 RLXFW1 systems require optional wired remote control. 4 Available only with optional wired remote control. 5 Available only with optional Interface kit. Operation monitoring and On/Off control only. 6 RLXWFH models only. 7 See page 13 for details. RLXFW1 RLXFWH 25 18RLXFW1 24RLXFW1 18RLXFWH 24RLXFWH t Performance Nominal Cooling BTUh 18,000 22,000 18,000 22,000 Min.-Max. Cooling BTUh 7,000~23,000 9,900~27,300 7,000~23,000 9,900~27,300 Nominal Heating BTUh 21,600 25,200 21,600 25,200 Min.-Max. Heating BTUh 7,000~29,000 7,500~36,200 7,000~29,000 7,500~36,200 SEER 20.0 19.5 20.0 19.5 HSPF 10.5 10.6 10.4 10.5 EER 13.3 12.5 13.3 12.5 Cooling Operating Range °F (°C) -5~115 (-20~46)-5~115 (-20~46)-5~115 (-20~46)-5~115 (-20~46) Heating Operating Range °F (°C) -5~75 (-20~24)-5~75 (-20~24)-15~75 (-26~24)-15~75 (-26~24) Moisture Removal Pt./h (l/h)5.9 (2.8)6.3 (3.0)5.9 (2.8)6.3 (3.0) Max Htg % of Nominal Capacity at +5˚F (-15˚C)*120% 105%120%105% Max Htg % of Nominal Capacity at -5˚F (-21˚C)*109%94%109%94% Max Htg % of Nominal Capacity at -15˚F (-26˚C)*--100%82% Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)541 (920)659 (1,120) 541 (920)659 (1,120) Medium CFM (m3/h)435 (740)530 (900)435 (740)530 (900) Low CFM (m3/h)365 (620)435 (740)365 (620)435 (740) Quiet CFM (m3/h)306 (520) 365 (620)306 (520) 365 (620) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Level (Clg/Htg): Hi dB(A)43/44 49/49 43/44 49/49 Medium dB(A)37/37 42/42 37/37 42/42 Low dB(A)33/33 37/37 33/33 37/37 Quiet dB(A)28/28 33/33 28/28 33/33 Outdoor Level Clg/Htg dB(A)47/50 54/55 47/50 54/55 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 20 30 20 20 Current Rated/Max: Cooling Amps 6.2/13.5 7.9/15.0 6.2/13.5 7.9/15 Current Rated/Max: Heating Amps 7.8/14.5 8.6/15.5 7.8/14.5 8.6/15.5 Power Use Rated/Max: Cooling kW 1.35/3.01 1.76/3.42 1.35/3.01 1.76/3.42 Power Use Rated/Max: Heating kW 1.80/3.23 2.38/3.53 1.75/3.23 1.94/3.53 Size & Weight Net Weight lbs. (kg) 31 (14)134 (61)31 (14)134 (61)31 (14)135 (61)31 (14) 135 (61) Dimensions: Height Inch 12-5/8 32-3/4 12-5/8 32-3/4 12-5/8 32-3/4 12-5/8 32-3/4 mm 320 830 320 830 320 830 320 830 Width Inch 39-1/4 35-3/8 39-1/4 35-3/8 39-1/4 35-3/8 39-1/4 35-3/8 mm 998 900 998 900 998 900 998 900 Depth Inch 9 13 9 13 9 13 9 13 mm 228 330 228 330 228 330 228 330 Refrigerant R410A R410A R410A R410A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Minimum Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5) Maximum Lineset Length Ft (m)164 (50) (pre-charge: 66’) 164 (50) (pre-charge: 66’) 164 (50) (pre-charge: 65’) 164 (50) (pre-charge: 65’) Max. Vertical Diff.Ft (m)98 (30)98 (30)98 (30)98 (30) Lineset Size Inch Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas5/8 Liq.3/8 Gas5/8 Liq.3/8 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70°F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data.IndoorASU18RLFOutdoorAOU18RLXFW1IndoorASU24RLFOutdoorAOU24RLXFW1IndoorASU18RLFOutdoorAOU18RLXFWHIndoorASU24RLFOutdoorAOU24RLXFWHNote: Figures are based on 230 Volts. SYSTEMS 18RLXFW1, 24RLXFW1 HIGH HEAT SYSTEMS 18RLXFWH, 24RLXFWH UP TO 20 SEER 26 SINGLE-ZONE MINI-SPLITS 30,000 BTUh WALL MOUNT HEAT PUMP MAX PIPE LENGTH System 30RLXEH246 ft. (75m) Max Height Diff. 98 ft. (30m) EXTENDED LINESET Long piping lengths between indoor and outdoor units provide flexibility and increased applications. LEAD-LAG FUNCTION Lead-lag function provides a redundant cooling system by pairing two 30RLXEH systems together delivering a unique solution for many applications.^ Lead-lag function provides the following operation modes: • Alternative Operation – units alternate operation, so neither unit is running at the same time. • Emergency Operation – if an error occurs on one unit, the second unit will turn on.* • Supporting Operation – if the setpoint cannot be reached with one unit alone, the second unit will come on to satisfy the demand for cooling. LOCK OUT FUNCTION This feature is set by the contractor on behalf of the Commercial Property Owner to prevent either Cooling or Heating operation from occurring. This is not a function that can be set by a tenant, user or home owner. 1 Economy ESP Minimum Heat Changeover Auto Adjust 4-Way Restart Dry Low Noise Powerful Quiet Mode Sleep Weekly 2 Cold 100% +5°F @ Ion Pump Down Sensor 2 I/O 3rd Party 3 -5˚F Cooling Heater Blue Fin 16 Daisy 2 164+ ft Piping Wi-Fi Capable 4 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wired remote control. 3 Available only with optional Interface kit. 4 See page 13 for details. HIGH PERFORMANCE HEATING CAPACITY The RLXEH model can operate down to -15°F. See the full story on page 14. ADDITIONAL APPLICATIONS THAT MAY REQUIRE LOW AMBIENT COOLING: • Conference/Meeting/Training Rooms • Social Gathering spots • Places of Worship OPTIONAL ACCESSORIES Wi-Fi Interface Module .......................................UTY-TFNXZ2^ Wi-Fi Interface Module ..........................................UTY-TFSXZ2 Wired Touch Panel Remote Controller .........UTY-RNRUZ Series Wired Remote Control ..........................................UTY-RVNUM Wired Remote Control ..........................................UTY-RNNUM Simple Remote Control .........................................UTY-RSNUM Interface Kit ..........................................................UTY-XCSXZ1 Interface Kit Box .......................................................UTZ-GXXB Outdoor Unit Input/Output Connector .................UTY-XWZXZ3 The 30RLXEH is specially engineered for applications that require cooling year round, and/or rooms with large heat loads such as classrooms and conference rooms. ^ Wired remotes cannot be used when using this feature. This includes UTY-RNRUZ Series, UTY-RVNUM, UTY-RNNUM, UTY-RSNUM. * Power loss to one of the two units will disengage the lead lag function. 27 HIGH-HEAT SYSTEM 30RLXEH 30RLXEH Performance Nominal Cooling BTUh 30,000 Min.-Max. Cooling BTUh 9,900~32,400 Nominal Heating BTUh 32,000 Min.-Max. Heating BTUh 8,000~37,500 SEER 18.7 HSPF 11.7 EER 12.5 Cooling Operating Range °F (°C) -5~115 (-20~46) Heating Operating Range °F (°C) -15~75 (-26~24) Moisture Removal Pt./h (l/h)9.7 (4.6) Max Htg % of Nominal Capacity at +5˚F (-15˚C)*107% Max Htg % of Nominal Capacity at -5˚F (-21˚C)*91% Max Htg % of Nominal Capacity at -15˚F (-26˚C)*76% Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)812 (1,380) Medium CFM (m3/h)665 (1,130) Low CFM (m3/h)536 (910) Quiet CFM (m3/h)418 (710) Fan Speed Stage 4+Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)50/49 Medium dB(A)45/44 Low dB(A)38/38 Quiet dB(A)32/32 Outdoor Sound Level Clg/Htg dB(A)53/54 Electrical Voltage/Frequency/Phase 208-230/60/1 Circuit Breaker Amps 30 Current Rated: Cooling Amps 10.6 Current Rated: Heating Amps 12.0 Power Use Rated/Max: Cooling kW 2.40/3.83 Power Use Rated/Max: Heating kW 2.74/4.28 Size & Weight Net Weight lbs. (kg) 40 (18) 205 (93) Dimensions: Height Inch 13-3/8 50-13/16 mm 340 1,290 Width Inch 45-1/4 35-3/8 mm 1,150 900 Depth Inch 11 13 mm 280 330 Refrigerant R410A Additional Data Air Direction: Horizontal Automatic Vertical Automatic Air Filter Washable Minimum Lineset Length Ft (m)16 (5) Maximum Lineset Length Ft (m)246 (75) (pre-charge: 65’) Max. Vertical Diff.Ft (m)98 (30) Lineset Size Inch Gas 5/8 Liq. 3/8 * Based on model # capacity class (e.g. 09LZAS1 based on 9,000 BTUh) @ 70°F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data. Note: Figures are based on 230 Volts.IndoorASU30RLEOutdoorAOU30RLXEHUP TO 18.7 SEER 28 9 AND 12,000 BTUh, 115V, WALL MOUNT HEAT PUMPS FUNCTION Stylish, slim and elegant, these popular wall mounted units are designed for single rooms. Indoor units have a clean, aesthetic design and are small but mighty and shorter in length than competing units, helping them blend into any room. EASY MAINTENANCE Front panel is easily removed for cleaning. 1 Economy Changeover Auto Adjust Up/Down Restart Dry Powerful Quiet Mode Sleep Cold Wi-Fi Capable 2 APPLICATIONS This category of equipment is ideal when the installation calls for 115 V service or the demand for ultra high efficiency is not present. Do you have a warm or cool spot in your home? Fujitsu mini-splits can provide extra cooling or heating capacity for those hard to cool areas. Commercially, their small size makes them ideal for small offices, providing individual temperature control. 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details. 2 See page 13 for details. SINGLE-ZONE MINI-SPLITS 29 16.0 SEER SYSTEMS 9RL2, 12RL2 9RL2 12RL2 Performance Nominal Cooling BTUh 9,000 12,000 Min.-Max. Cooling BTUh 1,700~10,700 3,100~12,500 Nominal Heating BTUh 10,000 14,000 Min.-Max. Heating BTUh 1,700~12,000 3,100~16,000 SEER 16.0 16.0 HSPF 9.0 9.0 EER 10.8 10.0 Cooling Operating Range °F (°C) 15~115 (-10~46)15~115 (-10~46) Heating Operating Range °F (°C) 15~75 (-10~24)15~75 (-10~24) Moisture Removal Pt./h (l/h)2.7 (1.3)3.8 (1.8) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)436 (740)436 (740) Medium CFM (m3/h)353 (600)353 (600) Low CFM (m3/h)265 (450)265 (450) Quiet CFM (m3/h)191 (325)191 (325) Fan Speed Stage 4 + Auto 4 + Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)43/43 43/43 Medium dB(A)38/38 38/38 Low dB(A)33/33 33/33 Quiet dB(A)23/23 23/23 Outdoor Sound Level Clg/Htg dB(A)47/48 51/51 Electrical Voltage/Frequency/Phase 115/60/1 115/60/1 Circuit Breaker Amps 15 20 Current Rated: Cooling Amps 7.5 10.9 Current Rated: Heating Amps 7.0 11.0 Power Use Rated: Cooling kW 0.83 1.20 Power Use Rated: Heating kW 0.77 1.21 Size & Weight Net Weight lbs. (kg) 16 (7)64 (29)16 (7)69 (31) Dimensions: Height Inch 10-5/16 21-1/4 10-5/16 21-1/4 mm 262 540 262 540 Width Inch 32-9/32 26 32-9/32 26 mm 820 660 820 660 Depth Inch 8-1/8 11-11/32 8-1/8 11-11/32 mm 206 290 206 290 Refrigerant R410A R410A Additional Data Air Direction: Horizontal Manual Manual Vertical Automatic Automatic Air Filter Washable Washable Minimum Lineset Length Ft (m)10 (3)10 (3) Maximum Lineset Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) Max. Vertical Diff.Ft (m)49 (15)49 (15) Lineset Diameter Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 IndoorASU9RL2OutdoorAOU9RL2IndoorASU12RL2OutdoorAOU12RL2 Note: Figures are based on 115 Volts. 30 FUNCTION Stylish, slim and elegant, these wall mounted ductless heat pumps are designed for single rooms. Ideal for spaces that require additional capacity but are limited on space. With more efficient zone control, ductless mini-splits are perfect for renovations, restorations, conversions and add-ons. OPTIONAL ACCESSORIES Wired Remote Control ..........................................UTY-RVNUM Wired Remote Control ..........................................UTY-RNNUM Simple Remote Control .........................................UTY-RSNUM Dry Contact Wire Kit ................................................UTY-XWZX Wi-Fi Interface Module .........................................UTY-TFNXZ2 LOCK OUT FUNCTION This feature is set by the contractor on behalf of the Commercial Property Owner to prevent either Cooling or Heating operation from occurring. This is not a function that can be set by a tenant, user or home owner. 18, 24, 30, 36,000 BTUh WALL MOUNT HEAT PUMPS AOU18RLB AOU24RLB AOU30RLXB AOU36RLXB SINGLE-ZONE MINI-SPLITS 1 Economy Minimum Heat Changeover Auto Adjust 4-Way Restart Dry Quiet Mode Sleep Weekly 2 Cold Ion Sensor 2 I/O 3rd Party 3 Blue Fin 4 16 Daisy 2 164+ ft Piping 4 Wi-Fi Capable 5 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wired remote control. 3 Available only with optional Interface kit. 4 RLXB models only. 5 See page 13 for details. 31 UP TO 19.0 SEER SYSTEMS 18RLB, 24RLB, 30RLXB, 36RLXB 18RLB 24RLB 30RLXB 36RLXB Performance Nominal Cooling BTUh 18,000 24,000 30,000 33,000 Min.-Max. Cooling BTUh 3,100~19,000 3,100~25,000 9,900~32,400 9,900~34,100 Nominal Heating BTUh 18,000 24,000 30,000 34,000 Min.-Max. Heating BTUh 7,000~20,000 7,500~27,000 8,000~33,000 10,200~35,000 SEER 19.0 18.0 16.5 15.5 HSPF 10.6 10.6 9.0 9.0 EER 12.5 10.0 9.5 8.5 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46) Heating Operating Range °F (°C) 5~75 (-15~24)5~75 (-15~24)5~75 (-15~24)5~75 (-15~24) Moisture Removal Pt./h (l/h)4.0 (1.9)6.3 (3.0)9.7 (4.6)10.1 (4.8) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)542 (920)659 (1,120) Clg 647 (1,100) Htg 659 (1,120) Clg 677 (1,150) Htg 695 (1,180) Medium CFM (m3/h)439 (740)530 (900)530 (900)530 (900) Low CFM (m3/h)365 (620)436 (740)436 (740)436 (740) Quiet CFM (m3/h)306 (520)365 (620)365 (620)365 (620) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)42/43 47/47 47/49 50/50 Medium dB(A)35/36 41/42 42/42 42/42 Low dB(A)31/33 35/36 37/37 37/37 Quiet dB(A)26/28 31/33 32/33 32/33 Outdoor Sound Level Clg/Htg dB(A)51/50 54/55 52/55 52/55 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 20 30 30 Current Rated/Max: Cooling Amps 6.4/8.3 10.5/11.8 13.8/16.8 17.0/18.0 Current Rated/Max: Heating Amps 5.8/11.8 8.5/13.8 12.3/18.8 14.8/18.8 Power Use Rated: Cooling kW 1.44/1.89 2.40/2.69 3.16/3.83 3.88/4.10 Power Use Rated: Heating kW 1.29/2.69 1.93/3.14 2.80/4.28 3.39/4.28 Size & Weight Net Weight lbs. (kg) 31 (14) 86 (39)31 (14) 86 (39)31 (14) 134 (61)31 (14) 134 (61) Dimensions: Height Inch 12-5/8 24-7/16 12-5/8 24-7/16 12-5/8 32-11/16 12-5/8 32-11/16 mm 320 620 320 620 320 830 320 830 Width Inch 39-5/16 31-1/8 39-5/16 31-1/8 39-5/16 35-7/16 39-5/16 35-7/16 mm 998 790 998 790 998 900 998 900 Depth Inch 9 11-7/16 9 11-7/16 9 13 9 13 mm 228 290 228 290 228 330 228 330 Refrigerant R410A R410A R410A R410A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Minimum Piping Length Ft (m)10 (3)10 (3)16 (5)16 (5) Maximum Piping Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 165 (50) (pre-charge: 66’) 165 (50) (pre-charge: 66’) Maximum Vertical Differential Ft (m)49 (15)49 (15)98 (30)98 (30) Lineset Size Inch Gas 1/2 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 IndoorASU18RLBOutdoorAOU18RLBIndoorASU24RLBOutdoorAOU24RLBIndoorASU30RLXBOutdoorAOU30RLXBIndoorASU36RLXBOutdoorAOU36RLXBNote: Figures are based on 230 Volts. 32 SINGLE-ZONE MINI-SPLITS 9, 12, 15,000 BTUh FLOOR MOUNT HEAT PUMPS At less than 24” high and 30” wide, floor mount models fit easily under a standard window and can replace a radiator twice its size while producing more capacity. Beneath standard window 27- 9/16” 23- 5/8” 29-1/8” 7-7/8” Standard concave portion Min. 27- 9/16” Min. 37” Low Wall Mount Max. 5-7/8” Half concealed* Min. 23- 1/4” Min. 28-3/4” Max. 3-1/8” * Field supplied insulation required FLEXIBLE AND EASY INSTALLATION TWO FANS AND WIDE AIRFLOW Having both upper and lower airflow quickly warms or cools the entire room. Floor mount can be set in “Upward Airflow Only” when occupants wish not to have feet warmed or cooled. 1 Economy Minimum Heat Changeover Auto Adjust Up/Down Restart Dry Powerful Quiet Mode 24 Hour Sleep Weekly 2 Cold 100% +5°F @ Ion Sensor 2 Heater 3 16 Daisy 2 Wi-Fi Capable 4 BASE PAN HEATER (RLFFH MODELS) RLFF models can operate down to -5°F. RLFFH models can operate down to -15°F. See the full story on page 14. Cooling Heating Window Fig. 1 Fig. 2 Fig. 1 Fig. 2 Cooling Heating Window Fig. 1 Fig. 2 Fig. 1 Fig. 2 1. Upon startup, both top and bottom louvers open. 2. As the room temperature nears the setpoint, only the top louver stays open to help prevent cold air from falling. OPTIONAL ACCESSORIES Wired Remote Control ..........................................UTY-RVNUM Wired Remote Controller ......................................UTY-RNNUM Simple Remote Control ..........................................UTY-RSNUM Dry Contact Wire Kit ............................................UTY-XWZXZ5 Wi-Fi Interface Module .........................................UTY-TFNXZ2 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available with optional wired remote control. 3 RLFFH models only. 4 See page 13 for details. 1. Upon startup, both top and bottom louvers open. 2. Closer to setpoint, only the top louver stays open to help prevent cold drafts from windows. IDEAL RADIATOR REPLACEMENT 33 SYSTEMS 9RLFF, 12RLFF, 15RLFF HIGH HEAT SYSTEMS 9RLFFH, 12RLFFH, 15RLFFH UP TO 26 SEER 9RLFF 12RLFF 15RLFF 9RLFFH 12RLFFH 15RLFFH Performance Nominal Cooling BTUh 9,000 12,000 14,200 9,000 12,000 14,200 Min.-Max. Cooling BTUh 3,100~13,000 3,100~14,300 3,100~17,700 3,100~13,000 3,100~14,300 3,100~17,700 Nominal Heating BTUh 12,000 16,000 18,000 12,000 16,000 18,000 Min.-Max. Heating BTUh 3,100~18,800 3,100~22,100 3,100~23,900 3,100~18,800 3,100~19,500 3,100~20,800 SEER 26.0 22.7 20.3 26.0 22.7 20.3 HSPF 12.6 11.6 11.2 12.4 11.3 11.0 EER 16.0 13.1 12.5 16.0 13.1 12.5 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46)14~115 (-10~46) Heating Operating Range °F (°C) -5~75 (-21~24)-5~75 (-21~24)-5~75 (-21~24)-15~75 (-26~24)-15~75 (-26~24)-15~75 (-26~24) Moisture Removal Pt./h (l/h)2.75 (1.3)3.8 (1.8)4.44 (2.1)2.75 (1.3)3.8 (1.8)4.44 (2.1) Max Htg % of Nominal Capacity at +5˚F (-15˚C)*149%125%118%149%125%118% Max Htg % of Nominal Capacity at -5˚F (-21˚C)*130%111%107%130%111%107% Max Htg % of Nominal Capacity at -15˚F (-26˚C)*------115%100%96% Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)335 (570)335 (570)383 (650)335 (570)335 (570)383 (650) Medium CFM (m3/h)271 (460)271 (460)306 (520)271 (460)271 (460)306 (520) Low CFM (m3/h)212 (360)212 (360)235 (400)212 (360)212 (360)235 (400) Quiet CFM (m3/h)159 (270)159 (270)159 (270)159 (270)159 (270)159 (270) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Level (Clg/Htg): Hi dB(A)40/40 40/40 44/43 40/40 40/40 44/43 Medium dB(A)35/35 35/35 38/37 35/35 35/35 38/37 Low dB(A)29/29 29/29 31/29 29/29 29/29 31/29 Quiet dB(A)23/23 23/23 23/23 23/23 23/23 23/23 Outdoor Level Clg/Htg dB(A)50/50 52/52 54/54 50/50 52/52 54/54 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 15 20 15 15 20 Current Rated: Cooling Amps 2.9 4.2 5.1 2.9 4.2 5.1 Current Rated: Heating Amps 4.1 6.7 7.0 4.1 6.7 7.0 Power Use Rated: Cooling kW .56 .97 1.13 .56 .97 1.13 Power Use Rated: Heating kW .88 1.44 1.58 .88 1.44 1.58 Size & Weight Net Weight lbs. (kg) 31 (14)84 (38)31 (14)84 (38)31 (14)86 (39)31 (14)86 (39)31 (14)86 (39)31 (14)88 (40) Dimensions: Height Inch 23-5/8 24-7/16 23-5/8 24-7/16 23-5/8 24-7/16 23-5/8 24-7/16 23-5/8 24-7/16 23-5/8 24-7/16 mm 600 620 600 620 600 620 600 620 600 620 600 620 Width Inch 29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8 mm 740 790 740 790 740 790 740 790 740 790 740 790 Depth Inch 7-7/8 11-7/16 7-7/8 11-7/16 7-7/8 11-7/16 7-7/8 11-7/16 7-7/8 11-7/16 7-7/8 11-7/16 mm 200 290 200 290 200 290 200 290 200 290 200 290 Refrigerant R410A R410A R410A R410A R410A R410A Additional Data Air Direction: Horizontal Manual Manual Manual Manual Manual Manual Vertical Auto Auto Auto Auto Auto Auto Air Filter Washable Washable Washable Washable Washable Washable Minimum Lineset Length Ft (m)10 (3)10 (3)10 (3)10 (3)10 (3)10 (3) Maximum Lineset Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) Max. Vertical Differential Ft (m)49 (15)49 (15)49 (15)49 (15)49 (15)49 (15) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70°F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data.IndoorAGU9RLFOutdoorAOU9RLFFIndoorAGU12RLFOutdoorAOU12RLFFIndoorAGU15RLFOutdoorAOU15RLFFIndoorAGU9RLFOutdoorAOU9RLFFHIndoorAGU12RLFOutdoorAOU12RLFFHIndoorAGU15RLFOutdoorAOU15RLFFHNote: Figures are based on 230 Volts. 34 Compact Cassette Grille UTG-CCGF shown is sold separately and must be ordered with each compact cassette. SINGLE-ZONE MINI-SPLITS FUNCTION The compact and stylish design of the cassette grille fits perfectly into a standard 24” square ceiling grid, with no overlapping of adjacent ceiling tiles. Features include high efficiency up to 24.0 SEER, heating at low temperatures down to -5°F, compact design, quiet operation, a standard wired remote control, and the ability to bring in fresh air through the optional Fresh Air Kit. FLEXIBLE INSTALLATION Since this panel fits into the ceiling grid, it can be installed in various locations. For example, you can install it next to recessed ceiling light fixtures. 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wireless remote control. 3 Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or 90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the height of the indoor unit. 4 Available only with optional Interface kit. Operation monitoring and On/Off control only. 5 See page 13 for details. 9, 12, 18,000 BTUh COMPACT CASSETTE HEAT PUMPS QUIET OPERATION Unique fan design (laminar wing design) provides whisper- quiet operation with sound pressure levels as low as 27dB(A). 1 Economy Minimum Heat 2 Changeover Auto Adjust Up/Down Restart Dry Fresh 3 Quiet Mode We ekly Cold 100% +5°F @ Ceiling Sensor I/O 3rd Party 4 Pump 16 Daisy Wi-Fi Capable 5 OPTIONAL ACCESSORIES Wired Remote Control ..........................................UTY-RVNUM Wireless remote ...................................................UTY-LNHUM F resh Air Kit ..............................................................UTZ-VXAA Wi-Fi Interface Module .........................................UTY-TFNXZ2 CONSISTENT AIRFLOW DISTRIBUTION The louver design maintains uniform room temperature by evenly spreading air throughout the space. Outer edge Ceiling Body of unit Round louver The new design spreads airflow evenly and widely across a space, helping to maintain consistent temperatures. 24 7/16” 24 7/16” 35 UP TO 24.0 SEER SYSTEMS 9RLFCC, 12RLFCC, 18RLFCC 9RLFCC 12RLFCC 18RLFCC Performance Nominal Cooling BTUh 9,000 12,000 18,000 Min.-Max. Cooling BTUh 3,100~12,000 3,100~13,600 3,100~20,100 Nominal Heating BTUh 12,000 16,000 21,600 Min.-Max. Heating BTUh 3,100~18,000 3,100~19,400 3,100~25,600 SEER 24.0 21.9 20.1 HSPF 13.0 12.2 11.5 EER 14.5 12.8 11.2 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14~115 (-10~46) Heating Operating Range °F (°C) -5~75 (-21~24)-5~75 (-21~24)-5~75 (-21~24) Moisture Removal Pt./h (l/h)1.3 (.06)2.5 (1.2)4.6 (2.2) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)318 (540)359 (610)400 (680) Medium CFM (m3/h)288 (490)312 (530)341 (580) Low CFM (m3/h)259 (440)277 (470)288 (490) Quiet CFM (m3/h)230 (390)241 (410)241 (410) Fan Speed Stage 4+auto 4+auto 4+auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)33/34 37/37 40/44 Medium dB(A)32/32 33/33 36/40 Low dB(A)29/29 31/31 32/36 Quiet dB(A)28/27 28/28 28/30 Outdoor Sound Level Clg/Htg dB(A)48/49 49/50 54/55 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 15 20 Current Rated: Cooling Amps 3.0 4.4 7.1 Current Rated: Heating Amps 4.1 6.7 7.7 Power Use Rated/Max: Cooling kW 0.62/1.40 0.94/1.45 1.61/2.15 Power Use Rated/Max: Heating kW 0.89/1.80 1.44/2.00 1.76/2.60 Size & Weight Net Weight lbs. (kg) 33 (15)84 (38)33 (15)84 (38)33 (15)86 (39) Dimensions: Height Inch 9-11/16 1-15/16 24-1/2 9-11/16 1-15/16 24-1/2 9-11/16 1-15/16 24-1/2 mm 245 49 620 245 49 620 245 49 620 Width Inch 22-7/16 24-7/16 31-3/32 22-7/16 24-7/16 31-3/32 22-7/16 24-7/16 31-3/32 mm 570 620 790 570 620 790 570 620 790 Depth Inch 22-7/16 24-7/16 11-11/32 22-7/16 24-7/16 11-11/32 22-7/16 24-7/16 11-11/32 mm 570 620 290 570 620 290 570 620 290 Refrigerant R410A R410A R410A Additional Data Air Direction: Vertical Automatic Automatic Automatic Air Filter Washable Washable Washable Minimum Lineset Length Ft (m)10 (3)10 (3)10 (3) Maximum Lineset Length Ft (m)66 (20)(pre-charge: 49’)66 (20)(pre-charge: 49’)66 (20)(pre-charge: 49’) Max. Vertical Diff.Ft (m)49 (15)49 (15)49 (15) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 IndoorAUU9RLFGrilleUTG-CCGFGOutdoorAOU9RLFCIndoorAUU12RLFGrilleUTG-CCGFGOutdoorAOU12RLFCIndoorAUU18RLFGrilleUTG-CCGFGOutdoorAOU18RLFC Note: Figures are based on 230 Volts. 36 SINGLE-ZONE MINI-SPLITS 9, 12, 18,000 BTUh SLIM DUCT HEAT PUMPS OPTIONAL ACCESSORIES Wired Remote Control ..........................................UTY-RVNUM W ireless Remote and Receiver .............................UTY-LRHUM Auto Louver Grille Kit (ARU7/9/12) ......................UTD-GX(S/T)A-W Auto Louver Grille Kit (ARU18) ..........................UTD-GX(S/T)B-W Wi-Fi Interface Module .........................................UTY-TFNXZ2 FUNCTION Slim ducts provide cooling or heating for small room applications such as offices, restaurants, convenience stores, motels, dorms, in retrofit and new construction. Long maximum combined piping length of 66’ and 49’ in height allow for versatile installations. Either horizontal or vertical flexibility and low height enables compact soffit or cabinet installation. BackBottom FLEXIBLE INSTALLATION Unit can be placed horizontally or vertically. However, internal drain pump will not operate when the unit is mounted in a vertical configuration. FIELD SUPPLIED FILTERS USED WITH SLIM DUCT UNITS Although Slim Duct units come with factory filters, when return ductwork is used field supplied filters are more practical to use. They can be installed at the unit or for more convenient servicing, in filter grilles. See the guidelines to the right to determine filter sizes. The chart includes CFM, external static pressure capability and a typical filter size for each model. Filters are sized to keep velocities and static pressure loss low. This will ensure sufficient static pressure is available for ductwork, fittings and supply and return grilles. Alternative filter sizes with equivalent face areas can be used. After deducting filter loss, available static pressure values are shown. ARU 9RLF ARU 12RLF ARU 18RLF CFM 353 383 547 Typical Filter Size 12 x 20 12 x 20 14 x 25 Velocity, FPM 212 230 228 Unit External SP, in. W.C.0.36 0.36 0.36 1” Fiberglass Filter *SP Loss, in. W.C.0.04 0.05 0.04 ^Available Static Pressure 0.32 0.31 0.32 1” MERV 8 Pleated Filter *SP Loss, in. W.C.0.12 0.14 0.14 ^Available Static Pressure 0.24 0.22 0.22 2” MERV 8 Pleated Filter *SP Loss, in. W.C.0.07 0.08 0.08 ^Available Static Pressure 0.29 0.28 0.28 *Typical filter pressure drop. ^Available Static Pressure factors in filter pressure loss only. A sample fiberglass filter is shown in blue to the left. A sample MERV pleated filter is shown in white. SLIM DUCT Built-in drain pump allows for installation of slim duct unit in smaller spaces than traditional units. Drain Pump13” Traditional 9.4” Slim Duct RETURN AIR-INTAKE CHOICES 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wireless remote control. 3 Available only with optional Interface kit. Operation monitoring and On/Off control only. 4 See page 13 for details. 1 Economy Minimum Heat 2 Changeover Auto Adjust Restart Dry Fresh Quiet Mode We ekly Cold 100% +5°F @ Sensor I/O 3rd Party 3 Pump 16 Daisy Wi-Fi Capable 4 37 SYSTEMS 9RLFCD, 12RLFCD, 18RLFCD UP TO 21.5 SEER 9RLFCD 12RLFCD 18RLFCD Performance Nominal Cooling BTUh 9,000 12,000 18,000 Min.-Max. Cooling BTUh 3,100~12,000 3,100~13,600 3,100~20,100 Nominal Heating BTUh 12,000 16,000 21,600 Min.-Max. Heating BTUh 3,100~18,000 3,100~19,400 3,100~25,600 SEER 21.5 20.0 19.7 HSPF 12.2 11.5 11.3 EER 14.5 12.8 12.0 Cooling Operating Range °F (°C) 14~115 (-10~46)14~115 (-10~46)14~115 (-10~46) Heating Operating Range °F (°C) -5~75 (-21~24)-5~75 (-21~24)-5~75 (-21~24) Moisture Removal Pt./h (l/h)1.5 (.07)2.7 (1.3)4.2 (2.0) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)353 (600)383 (650)554 (940) Medium CFM (m3/h)324 (550)353 (600)518 (880) Low CFM (m3/h)294 (500)324 (550)483 (820) Quiet CFM (m3/h)265 (450)283 (480)442 (750) Fan Speed Stage 4+auto 4+auto 4+auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)28/28 29/29 32/32 Medium dB(A)27/26 28/28 30/30 Low dB(A)26/25 27/27 29/29 Quiet dB(A)25/24 26/24 27/27 Outdoor Sound Level Clg/Htg dB(A)48/49 49/50 54/55 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 15 20 Current Rated: Cooling Amps 3.0 4.4 6.6 Current Rated: Heating Amps 3.9 6.0 7.3 Power Use Rated/Max: Cooling kW 0.62/1.40 0.94/1.45 1.50/2.15 Power Use Rated/Max: Heating kW 0.85/1.80 1.30/2.00 1.67/2.60 Size & Weight Net Weight lbs. (kg) 41 (19)84 (38)41 (19)84 (38)50 (23)86 (39) Dimensions: Height Inch 7-25/32 5-15/16 6 24-1/2 7-25/32 5-15/16 6 24-1/2 7-25/32 5-15/16 6 24-1/2 mm 198 151 152 620 198 151 152 620 198 151 152 620 Width Inch 27-9/16 25- 19/32 22 31-3/32 27-9/16 25- 19/32 22 31-3/32 35-7/16 33- 15/32 30 31-3/32 mm 700 650 559 790 700 650 559 790 900 850 762 790 Depth Inch 24- 13/32 3/4 3/4 Flat 11- 11/32 24- 13/32 3/4 3/4 Flat 11- 11/32 24- 13/32 3/4 3/4 Flat 11- 11/32 mm 620 19 19 Flat 290 620 19 19 Flat 290 620 19 19 Flat 290 Refrigerant R410A R410A R410A Additional Data Static Pressure in. W. C.0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 Air Filter Washable Washable Washable Minimum Lineset Length Ft (m)10 (3)10 (3)10 (3) Maximum Lineset Length Ft (m)66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) 66 (20) (pre-charge: 49’) Max. Vertical Diff.Ft (m)49 (15)49 (15)49 (15) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 IndoorARU9RLFSUPPLY DUCT FLANGERETURN DUCTOutdoorAOU9RLFCIndoorARU12RLFSUPPLY DUCT FLANGERETURN DUCTOutdoorAOU12RLFCIndoorARU18RLFSUPPLY DUCT FLANGERETURN DUCTOutdoorAOU18RLFC Note: Figures are based on 230 Volts. 38 Energy efficient DC fan motor Lower power consumption Noise Level 24dB(A)* V-shape heat exchanger Air Stabilizer * 12,18, 24,000 BTUh models fan speed: Quiet 12, 18, 24, 30, 36, 42, 48,000 BTUh MEDIUM STATIC DUCTED HEAT PUMPS AOU18/24/30/36RGLXARU36/42/48RGLXARU18/24/30RGLXARU12RGLX AOU42/48RGLX ENERGY EFFICIENT & QUIET OPERATION The combination of the V-shaped heat exchanger, air stabilizer, and the energy efficient DC fan motor results in high efficiency and quiet operation. The 12, 18 and 24,000 BTUh models are Energy Star qualified. OPTIONAL ACCESSORIES Wired Remote Controller .............................UTY-RNRUZ Series Simple Remote Controller .......................UTY-RSRY, UTY-RHRY Thermostat Converter ................................................UTY-TTRX Wi-Fi Interface Module ..........................................UTY-TFSXZ2 External Input and Output PCB .................................UTY-XCSX Remote Sensor Unit .................................................UTY-XSZX FEATURE HIGHLIGHTS • Static pressure up to 0.80” W.G. (12/18/24/30/36k models) • Max piping lengths of up to 246 feet (42/48RGLXD systems) • Medium Static Ducted units must be installed horizontally • Heating and cooling operation rated down to -5˚F outdoor temperature • Multiple control options available • Built-in drain pump • Automatic static pressure detection for install conditions • Anti-corrosive coil coating on outdoor unit FUNCTION Fujitsu is proud to introduce the newest addition to our single-zone mini-split lineup – three new Medium Static Pressure Duct indoor units! These units use the same energy efficient inverter technology you expect from Fujitsu mini- split products, and they have enough static pressure to heat or cool a whole house. SEER ratings up to 21.3 and a compact size mean these indoor units can find a place in many applications. SINGLE-ZONE MINI-SPLITS AOU12RLFC Note: Indoor unit will NOT include any wireless or wired controllers in the box. Given that the medium-static RGLX unit is compatible with multiple control options the customer now has the option to choose the controller that best suits their needs. 1 Economy Minimum Heat Changeover Auto Adjust Restart Dry Fresh Low Noise 2 Quiet Mode 24 Hour Sleep 3 Weekly 4 Cold 100% +5°F @ 5 Pump Down Sensor 4 I/O 3rd Party 6 Cooling 0˚F 7 -5˚F Cooling 7 Pump 16 Daisy 164+ ft Piping 7 Wi-Fi Capable 8 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 42, 48,000 BTUh systems only 3 Available only with optional wireless remote control. 4 Available only with optional wired remote control. 5 12,000 BTHu system only 6 Available only with optional Interface kit. Operation monitoring and On/Off control only. 7 18, 24, 30, 36, 42, 48,000 BTUh systems only. 8 See page 13 for details. INFINITE COMFORT SERIES 39 SYSTEMS 12RGLXD, 18RGLXD, 24RGLXD, 30RGLXD, 36RGLXD, 42RGLXD, 48RGLXD 12RGLXD 18RGLXD 24RGLXD 30RGLXD 36RGLXD 42RGLXD 48RGLXD Performance Nominal Cooling BTUh 12,000 18,000 24,000 30,000 36,000 42,000 48,000 Min.-Max. Cooling BTUh 3,100-13,600 5,400-21,500 5,400-29,000 9.600-35,000 9,600-39,000 17,100-45,000 17,100-50,000 Nominal Heating BTUh 16,000 21,000 27,000 32,000 36,000 47,000 53,000 Min.-Max. Heating BTUh 3,100-19,400 5,400-25,600 5,400-32,400 9,200-39,000 9,200-48,000 18,000-51,000 18,000-55,000 SEER 21.3 19.0 17.5 16.5 16.7 17.8 16.6 HSPF 11.7 10.9 10.8 10.4 11.3 10.5 10.3 EER 13.4 13.0 12.6 10.6 10.0 11.5 10.1 Cooling Operating Range °F (°C)14 - 115 (-20 - 46) -5 - 115 (-20 - 46) -5 - 115 (-20 - 46) -5 - 115 (-20 - 46) -5 - 115 (-20 - 46) -5 - 115 (-20 - 46) -5 - 115 (-20 - 46) Heating Operating Range °F (°C)-5 - 75 (-20 - 24) -5 - 75 (-20 - 24) -5 - 75 (-20 - 24) -5 - 75 (-20 - 24) -5 - 75 (-20 - 24) -5 - 75 (-20 - 24) -5 - 75 (-20 - 24) Moisture Removal Pt./h (l/h)1.5 (0.7)3.8 (1.8)4.0 (1.9)5.1 (2.4)5.3 (2.5)5.5 (2.6)8.2 (3.9) Fan (Cooling Mode) Air Circulation (Clg/Htg): Hi CFM (m3/h)500 (850)618 (1050)800 (1360)1001 (1700)1207 (2050) / 1089 (1850) 1501(2550)1501 (2550) Medium CFM (m3/h)400 (680)494 (840)636 (1080)800 (1360)965 (1640)1201 (2040)1201 (2040) Low CFM (m3/h)347 (590)430 (730)518 (880)700 (1190)783 (1330)971 (1650)971 (1650) Quiet CFM (m3/h)300 (510)371 (630)400 (680)630 (1070)630 (1070)842 (1430)842 (1430) Fan Speed Stage 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto Sound Indoor Level (Clg/Htg): Hi dB(A)35/35 31/31 35/35 38/38 37/35 40/40 40/40 Medium dB(A)30/30 28/28 30/30 34/34 33/33 35/35 35/35 Low dB(A)27/27 25/25 28/28 30/30 30/30 33/33 33/33 Quiet dB(A)24/24 24/24 24/24 29/29 26/26 29/29 29/29 Outdoor Level Clg/Htg dB(A)49/50 47/50 53/55 53/55 54/56 55/57 57/59 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 15 20 30 30 30 30 30 Current Rated: Cooling Amps 3.9 6.1 8.3 12.4 15.8 16.0 20.9 Current Rated: Heating Amps 5.3 6.6 9.0 10.9 12.6 16.1 19.5 Power Use Rated/Max: Cooling kW 0.89/1.45 1.38/2.08 1.90/2.82 2.83/3.43 3.60/4.00 3.65/4.47 4.75/5.01 Power Use Rated/Max: Heating kW 1.20/1.84 1.50/2.19 2.06/2.96 2.48/3.27 2.88/4.38 3.67/4.57 4.45/4.77 Size & Weight Net Weight lbs. (kg) 66 (30) 84 (38) 93 (42) 134 (61) 93 (42) 134 (61) 93 (42) 134 (61) 121 (55) 134 (61) 121 (55) 209 (95) 121 (55) 209 (95) Dimensions: Height Inch 11-13/16 24-1/2 11-13/16 32-11/16 11-13/16 32-11/16 11-13/16 32-11/16 11-13/16 32-11/16 11-13/16 50-13/16 11-13/16 50-13/16 mm 300 620 300 830 300 830 300 830 300 830 300 1290 300 1290 Width Inch 27- 9/16 31-3/32 39-3/8 35-7/16 39-3/8 35-7/16 39-3/8 35-7/16 55-1/8 35-7/16 55-1/8 35-7/16 55-1/8 35-7/16 mm 700 790 1000 900 1000 900 1000 900 1400 900 1400 900 1400 900 Depth Inch 27-9/16 11-11/32 27-9/16 13 27-9/16 13 27-9/16 13 27-9/16 13 27-9/16 13 27-9/16 13 mm 700 290 700 330 700 330 700 330 700 330 700 330 700 330 Refrigerant R410A R410A R410A R410A R410A R410A R410A Additional Data Static Pressure in. W. C.0.12 - 0.80 0.12 - 0.80 0.12 - 0.80 0.12 - 0.80 0.12 - 0.80 0.12 - 0.72 0.12 - 0.72 Min Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5)16 (5)16 (5)16 (5) Max Lineset Length Ft (m)66 (20) (pre-charge 49’) 164 (50) (pre-charge 66’) 164 (50) (pre-charge 66’) 164 (50) (pre-charge 66’) 164 (50) (pre-charge 66’) 246 (75) (pre-charge 98’) 246 (75) (pre-charge 98’) Max Vertical Diff.Ft (m)49 (15)98 (30)98 (30)98 (30)98 (30)98 (30)98 (30) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Indoor ARU12RGLXOutdoor AOU12RLFCIndoor ARU18RGLXOutdoor AOU18RGLXIndoor ARU24RGLXOutdoor AOU24RGLXIndoor ARU30RGLXOutdoor AOU30RGLXIndoor ARU36RGLXOutdoor AOU36RGLXIndoor ARU42RGLXOutdoor AOU42RGLXIndoor ARU48RGLXOutdoor AOU48RGLX 40 SINGLE-ZONE MINI-SPLITS 24, 30, 36, 48,000 BTUh MULTI-POSITION AIR HANDLER UNITS INFINITE COMFORT SERIES SYSTEM FEATURES • True Multi-Position Design - up flow, down flow, & horizontal • High Energy Saving - Inverter driven heat pump, high efficiency ECM motor, and all-aluminum indoor unit coil. OUTDOOR UNIT FEATURES • Fully communicating heat pump with conventional multi- position air handler. Ideal solution for installations with limited space • Variable speed inverter-driven compressor for optimum system operation and comfort • Outdoor sound levels as low as 53 dBA • High efficiency DC motor • Single fan outdoor unit - Save space without compromise UPFLOW AIRFLOW DOWNFLOWAIRFLOW HORIZONTAL LEFTAIRFLOW AIRFLOWHORIZONTAL RIGHT THE INFINITE COMFORT SERIES IS 4X QUIETER! You’d need FOUR Infinite Comfort Series units to equal the sound level of ONE unitary air conditioner. = OPTIONAL ACCESSORIES Wired Remote Controller .............................UTY-RNRUZ Series Simple Remote Controller ......................UTY-RSRY / UTY-RHRY Wireless LAN Interface ..........................................UTY-TFSXZ2 Thermostat Converter ................................................UTY-TTRX External Input and Output PCB* ................................UTY-XCSX External Connect Kit ............................................UTY-XWZXZG Wire Kit .................................................................UTY-XWZXZJ * The wireless LAN interface cannot be used at the same time. External Connect Kit (UTY-XWZXZG) is required for the connection AMUG24-30LMAS AMUG36-48LMAS AOUG36-48LMAS1AOU24-30RGLX Leveraging our cutting edge inverter technology, Fujitsu’s Infinite Comfort series combines our revolutionary side discharge outdoor units with a modular design indoor unit. The result: high efficiency, space saving, and quiet single- zone systems with no compromise. 1 Economy Minimum Heat Changeover Auto Adjust Restart Dry Fresh Low Noise 2 Quiet Mode 24 Hour Sleep 3 Weekly 4 Cold Pump Down Sensor 4 I/O 3rd Party 5 Cooling 0˚F -5˚F Cooling 6 Blue Fin 16 Daisy 164+ ft Piping Wi-Fi Capable 7 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 42, 48,000 BTUh systems only 3 Available only with optional wireless remote control. 4 Available only with optional wired remote control. 5 Available only with optional Interface kit. Operation monitoring and On/Off control only. 6 24, 30 BTU/h systems only. 7 See page 13 for details. INDOOR UNIT FEATURES • All-aluminum indoor unit coil • High static pressure, up to 1.0 inWG • Indoor sound levels as low as 24 dBA • Adaptive fan motor control - Optimum indoor comfort • Minimal clearance on three sides. Only 24in. clearance on the front for service. • Downflow and Horizontal Right kits provided with each AHU at no additional cost • Factory provided and field installed electric heat kit - Up to 15.5kW (Optional) • External Input/Output Interface - Interlock with 3rd party systems. (Optional) 41 SYSTEMS 24RGLXM, 30RGLXM, 36LMAS1, 48LMAS1 24RGLXM 30RGLXM 36LMAS1 48LMAS1 Performance Nominal Cooling BTUh 24000 30000 36000 45600 Min.-Max. Cooling BTUh 5,400 - 29,000 9,600 - 35,000 13,000 - 38,000 13,000 - 48,000 Nominal Heating BTUh 27000 32000 42000 53000 Min.-Max. Heating BTUh 5,400 - 32,400 9,200 - 39,000 11,000 - 52,000 11,000 - 54,000 SEER 19 18.5 18 17 HSPF 10.7 10.3 10.2 10.2 EER 12 10.1 11.3 8.2 Cooling Operating Range °F (°C)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46)14 - 115 (-10 - 46)14 - 115 (-10 - 46) Heating Operating Range °F (°C)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24) Moisture Removal Pt./h (l/h)4.6 (2.2)7.2 (3.4)7.2 (3.4)9.3 (4.4) Fan (Cooling Mode) Air Circulation (Clg/Htg): Hi CFM (m3/h)800 (1359)870 (1478)1200 (2039)1640 (2786) Medium CFM (m3/h)670 (1138)730 (1240)740 (1257)1020 (1733) Low CFM (m3/h)590 (1002)590 (1002)590 (1002)820 (1393) Quiet CFM (m3/h)310 (527)310 (527)490 (833)590 (1002) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Indoor Level (Clg/Htg): Hi dB(A)40/37 42/39 41/40 48/47 Medium dB(A)34/33 37/36 30/35 36/37 Low dB(A)32/31 33/32 27/28 31/32 Quiet dB(A)26/25 28/25 24/26 25/29 Outdoor Level Clg/Htg dB(A)53/55 53/55 53/54 54/55 Electrical Voltage/Frequency/Phase 208-230V/60Hz/1 208-230V/60Hz/1 208-230V/60Hz/1 208-230V/60Hz/1 Circuit Breaker Amps 30 30 40 40 Current Rated: Cooling Amps 8.8 13 14 24.418 Current Rated: Heating Amps 10.9 13.26 16.8 23.5 Power Use Rated/Max: Cooling kW 2/3.47 2.97/3.41 3.18/3.52 5.56/5.94 Power Use Rated/Max: Heating kW 2.48/3.47 3.02/4.16 3.82/5.39 5.35/5.42 Size & Weight Net Weight lbs. (kg)104 (47)134 (61)104 (47)134 (61)132 (60)198 (90)132 (60)198 (90) Dimensions: Height Inch 42-8/16 32-11/16 42-8/16 32-11/16 57 39-5/16 57 39-5/16 mm 1080 830 1080 830 1448 998 1448 998 Width Inch 21 35-7/16 21 35-7/16 21 38-3/16 21 38-3/16 mm 533 900 533 900 533 970 533 970 Depth Inch 21-11/16 13 21-11/16 13 21-11/16 14-9/16 21-11/16 14-9/16 mm 551 330 551 330 551 370 551 370 Refrigerant 410A 410A 410A 410A Additional Data Static Pressure in. W. C.0-1.0 (20-250 )0-1.0 (20-250 )0-1.0 (20-250 )0-1.0 (20-250 ) Min Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5) Max Lineset Length Ft (m)164 (50) (pre-charge 66’) 164 (50) (pre-charge 66’) 230 (70) (pre-charge 98’) 230 (70) (pre-charge 98’) Max Vertical Diff.Ft (m)98 (30)98 (30)98 (30)98 (30) Lineset Size Inch 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 AMUG24LMASAOU24RGLXAMUG30LMASAOU30RGLXAMUG36LMASAOUG36LMAS1AMUG48LMASAOUG48LMAS1 42 SINGLE-ZONE MINI-SPLITS OPTIONAL ACCESSORIES Wired Remote Control ...........................................UTY-RNBYU Requires dip switch change on indoor unit. Condensate Pump ................................................UTR-DPB24T Available only for System 36RSLX. FUNCTION The 18RULX and the 24RULX are universal mount. They can mount low on the wall or transverse mount them on the ceiling. The 36RSLX can only be mounted on the ceiling, can take in fresh air and can throw air farther. 18, 24, 36,000 BTUh CEILING & UNIVERSAL HEAT PUMPS 1 Available only with optional wired remote control. 2 Fresh air knockout available. Fresh air fan and ductwork field supplied. See Design and Technical Manual for details. 3 See page 13 for details. 2 Saving 1 Changeover Auto Adjust 4-Way Restart Dry Fresh 2 24 Hour Sleep Weekly 1 Cold Ceiling Pump Down Sensor 1 Cooling 0˚F 16 Daisy 164+ ft Piping Wi-Fi Capable 3 APPLICATIONS The universal floor/ceiling mount 18RULX and 24RULX are ideal for a house of worship to mount beneath stained glass windows. Lower in height than the pews, they do not disturb the aesthetics of the space. With long piping lengths of 165’ the outdoor units can also be placed remotely out of sight. Another popular application for this model is in hallways where wall space is limited. The 36RSLX is popular where fresh air intake and high capacity is required like a restaurant or bar. They are also often suspended from threaded rod and used in multiple to condition large warehouse spaces. 43 UP TO 16 SEER SYSTEMS 18RULX, 24RULX, 36RSLX 18RULX 24RULX 36RSLX Performance Nominal Cooling BTUh 17,800 22,200 34,100 Min.-Max. Cooling BTUh 5,000~21,600 5,000~27,300 8,500~36,000 Nominal Heating BTUh 21,500 24,000 36,500 Min.-Max. Heating BTUh 5,000~25,600 5,000~29,000 9,200~42,700 SEER 16.0 15.0 14.0 HSPF 8.5 8.5 8.5 EER 10.9 9.9 8.1 Cooling Operating Range °F (°C) 0~115 (-18~46)0~115 (-18~46)0~115 (-18~46) Heating Operating Range °F (°C) 14~75 (-10~24)14~75 (-10~24)14~75 (-10~24) Moisture Removal Pt./h (l/h)5.3 (2.5)7.4 (3.5)7.4 (3.5) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)459 (780)518 (880)1089 (1850) Medium CFM (m3/h)383 (650)436 (740)977 (1660) Low CFM (m3/h)324 (550)371 (630)842 (1430) Fan Speed Stage 3 + Auto 3 + Auto 3 + Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)43/43 (Clg/Htg)47/47 (Clg/Htg)48/48 (Clg/Htg) Medium dB(A)39/39 (Clg/Htg)43/43 (Clg/Htg)45/43 (Clg/Htg) Low dB(A)35/35 (Clg/Htg)38/38 (Clg/Htg)41/39 (Clg/Htg) Outdoor Sound Level Clg/Htg dB(A)51/53 53/55 54/55 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 20 20 30 Current Rated/Max: Cooling Amps 7.1/12.5 9.8/12.5 18.3/18.8 Current Rated/Max: Heating Amps 9.8/12.5 10.2/12.5 15.3/18.8 Power Use Rated/Max: Cooling kW 1.63/2.88 2.25/2.88 4.22/4.35 Power Use Rated/Max: Heating kW 2.25/2.88 2.35/2.88 3.50/4.35 Size & Weight Net Weight lbs. (kg) 62 (28)141 (64)62 (28)141 (64)106 (48)141 (64) Dimensions: Height Inch 7-7/8 32-3/4 7-7/8 32-3/4 9-1/2 32-3/4 mm 199 830 199 830 240 830 Width Inch 39-1/8 35-1/2 39-1/8 35-1/2 65-1/2 35-1/2 mm 990 900 990 900 1660 900 Depth Inch 25-7/8 13 25-7/8 13 27-5/8 13 mm 655 330 655 330 700 330 Refrigerant R410A R410A R410A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Vertical Automatic Automatic Automatic Air Filter Washable Washable Washable Front Grille Permanent Permanent Permanent Minimum Lineset Length Ft (m)16 (5)16 (5)16 (5) Maximum Lineset Length Ft (m)165 (50) (pre-charge: 49’) 165 (50) (pre-charge: 49’) 165 (50) (pre-charge: 49’) Max. Vertical Diff.Ft (m)66 (20)66 (20)98 (30) Lineset Size Inch Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 IndoorABU18RULXOutdoorAOU18RLXIndoorABU24RULXOutdoorAOU24RLXIndoorABU36RSLXOutdoorAOU36RLXNote: Figures are based on 230 Volts. 44 RECOMMENDED ACCESSORIES NOTE: RGLX Large Cassette grilles are sold seperately. Circular flow cassette grilles come in your choice of either black or white. SINGLE-ZONE MINI-SPLITS 18, 24, 30, 36, 42,000 BTUh LARGE CASSETTE CIRCULAR FLOW HEAT PUMPS 1 Economy ESP 2 Minimum Heat Changeover Auto Adjust Up/Down Restart Dry Fresh Low Noise 3 Quiet Mode 24 Hour Sleep 4 Weekly 5 Cold Ceiling Pump Down Sensor 5 I/O 3rd Party 6 Cooling 0˚F -5˚F Cooling Branch Pump 16 Daisy 164+ ft Piping Slender Wi-Fi Capable 7 AOU18/24/30/36RGLX AOU42/48RGLXAUU18/24RGLX with UTG-LCGVCB AUU30/36/42/48RGLX with UTG-GCGF BETTER AIR DISTRIBUTION USING 360-DEGREE LOUVERS Circular flow design allows conditioned air to reach every corner of a room. INDIVIDUAL LOUVER CONTROL Each louver can be positioned individually to deliver comfortable air exactly where you want it in any room configuration. To take advantage of this feature use Wired Remote Control (Touch Panel) UTY-RNRUZ Series. Efficient air conditioning in accordance with the room layout Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging air flow simultaneously Efficient air conditioning in accordance with the room layout Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging air flow simultaneously Indivual louvers can be programmed seperately. Adjust vertical airflow and louver position with UTY-RNRUZ Series Wired Remote Control. Airflow fan speed can be customized depending on room layout. HIGH ENERGY EFFICIENCY Energy saving performance is achieved through use of a DC twin rotary compressor, DC fan motor and optimized refrigerant cycle control. 18,000 BTUh and 24,000 BTUh models are Energy Star qualified. 15.0 20.0+25% RGLX modelRCLX model 8.5 10.8+20% RGLX modelRCLX model HSPF (24k BTUh model)SEER (24k BTUh model) QUIET OPERATION AND 4 FAN SPEED CONTROL With the new airflow structure, sound levels are drastically reduced. Circular flow cassette models operate at whisper quiet sound levels. Choose from 4 different fan speeds. RGLX modelRCLX model -10dB(A)45dB(A) 35dB(A) High Med Low Quiet 4 fan speeds *Compatible Remote Controller is as follows: UTY-RNRUZ2 / UTY-RSRY / UTY-RHRY / UTY-LBTUC 24k BTUh model (Cooling / High) UTG-LCGVCB UTG-GCGF NOTE: Wired Remote Control sold seperately. RGLX Large Cassettes are compatible with UTY-RNRUZ Series 2-wire controls. Wired Remote Control (Touch Panel) ..................................UTY-RNRUZ Series Simple Remote Control ....................................................UTY-RSRY, UTY-RHRY Wi-Fi Interface Module ..................................................................UTY-TFSXZ2 External Input and Output PCB ........................................................UTY-XCSX* Communication Kit Bracket ..............................................................UTZ-GXRA IR Receiver Unit ..............................................................................UTY-LBTUC Human Sensor Kit ..........................................................................UTY-SHZXC Air Outlet Shutter Plate ....................................................................UTR-YDZK External Connect Kit ...............................................UTY-XWZXZG, UTY-XWZXZ3 Wide Panel ..................................................................................UTG-AKXA-W Panel Spacer ...............................................................................UTG-BKXA-W Fresh Air Intake Kit .......................................................................KHRS940-25 Fresh Air Kit ......................................................................................UTZ-VXRA OPTIONAL ACCESSORIES (cont’d on bottom of page 45) 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional part UTY-SHZXC. 3 42, 48,000 BTUh systems only. 4 Available only with optional wireless remote control. 5 Available only with optional wired remote control. 6 Available only with optional Interface kit. Operation monitoring and On/Off control 7 See page 13 for details. 45 SYSTEMS 18RGLXC, 24RGLXC, 30RGLXC, 36RGLXC, 42RGLXC, 48RGLXC 18RGLXC 24RGLXC 30RGLXC 36RGLXC 42RGLXC 48RGLXC Performance Nominal Cooling BTUh 18,000 24,000 30,000 36,000 42,000 48,000 Min.-Max. Cooling BTUh 5,400—21,500 5,400—29,000 9,600—35,000 9,600—39,000 17,100—45,000 17,100-50,000 Nominal Heating BTUh 21,000 27,000 32,000 36,000 47,000 53,000 Min.-Max. Heating BTUh 5,400—25,600 5,400—32,400 9,200—39,000 9,200—48,000 18,000—51,000 18,000-55,000 SEER 21.4 20 18.6 17.5 18.5 17.8 HSPF 10.9 10.8 11.5 11.2 9.7 10.6 EER Btu/hW 13.4 12.8 11.7 10 11.3 10.1 Cooling Operating Range °F (°C)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46)-5 - 115 (-20 - 46) Heating Operating Range °F (°C)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24)-5 - 75 (-20 - 24) Moisture Removal Pt./h (l/h)3.9 (2.2)5.1 (2.9)5.3 (3.0)6.5 (3.7)7.7 (4.4)9.3 (5.3) Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)618 (1,050)677 (1,150)942 (1,600)1,118 (1,900)1,177 (2,000)1,236 (2,100) Medium CFM (m3/h)565 (960)618 (1,050)824 (1,400)936 (1,590)971 (1,650)1,048 (1,780) Low CFM (m3/h)530 (900)577 (980)748 (1,270)836 (1,420)859 (1,460)942 (1,600) Quiet CFM (m3/h)459 (780)512 (870)677 (1,150)695 (1,180)765 (1,300)777 (1,320) Fan Speed Stage 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)33/33 35/35 40/40 44/44 46/46 47/47 Medium dB(A)32/32 34/34 38/38 41/41 42/42 43/43 Low dB(A)31/31 32/32 36/36 38/38 39/39 40/40 Quiet dB(A)28/28 29/29 33/33 34/34 35/35 36/36 Outdoor Sound Level Clg/Htg dB(A)47/50 53/55 53/55 54/56 55/57 57/59 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Circuit Breaker Amps 20 30 30 30 30 30 Current Rated: Cooling Amps 6.1 8.4 11.5 16.1 16.7 20.9 Current Rated: Heating Amps 6.6 9.6 10.7 12.2 16.8 19.5 Power Use Rated/Max: Cooling kW 1.35/2.05 1.88/2.77 2.57/3.33 3.60/3.94 3.72/4.35 4.75/4.91 Power Use Rated/Max: Heating kW 1.47/2.27 2.15/2.88 2.38/3.27 2.73/4.19 3.74/4.39 4.49/4.67 Size & Weight Net Weight lbs. (kg)53 (24) 134 (61) 53 (24) 134 (61) 57 (26) 134 (61) 57 (26) 134 (61) 64 (29) 209 (95) 64 (29) 209 (95) Dimensions: Height Inch 9 11/16 32 11/16 9 11/16 32 11/16 11 5/16 32 11/16 11 5/16 32 11/16 11 5/16 50 13/16 11 5/16 50 13/16 mm 246 830 246 830 288 830 288 830 288 1290 288 1290 Width Inch 33 1/16 35 7/16 33 1/16 35 7/16 33 1/16 35 7/16 33 1/16 35 7/16 33 1/16 35 7/16 33 1/16 35 7/16 mm 840 900 840 900 840 900 840 900 840 900 840 900 Depth Inch 33 1/16 13 33 1/16 13 33 1/16 13 33 1/16 13 33 1/16 13 33 1/16 13 mm 840 330 840 330 840 330 840 330 840 330 840 330 Refrigerant R410A R410A R410A R410A R410A R410A Additional Data White Grille (UTG-GCGF) or Black Grille (UTG-LCGVCB) Sold Separately Minimum Lineset Length Ft (m)16 (5)16 (5)16 (5)16 (5)16 (5)16 (5) Maximum Lineset Length Ft (m)164 (50) Precharge 66’ 164 (50) Precharge 66’ 164 (50) Precharge 66’ 164 (50) Precharge 66’ 246 (75) Precharge 98’ 246 (75) Precharge 98’ Max. Vertical Diff.Ft (m)98 (30)98 (30)98 (30)98 (30)98 (30)98 (30) Lineset Size Inch Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Gas 5/8 Liq. 3/8 Indoor AUU18RGLXOutdoor AOU18RGLXIndoor AUU24RGLXOutdoor AOU24RGLXIndoor AUU30RGLXOutdoor AOU30RGLXIndoor AUU36RGLXOutdoor AOU36RGLXIndoor AUU42RGLXOutdoor AOU42RGLXIndoor AUU48RGLXOutdoor AOU48RGLXOptional Accessories, cont’d: Thermostat Converter - UTY-TTRX - Control your Fujitsu heating and cooling system with your favorite smart thermostat (not included). Wi-Fi Module - UTY-TFNXZ2 - Add wireless capability to your Fujitsu system through FGLair. Cannot be installed in conjunction with Wired Remote Controls. IR Wireless Module - FJ-IR-WIFI-1NA, Wired Module - FJ-RC-WIFI-1NA - The IR Wireless and Wired Modules work with the Intesis AC Cloud Control¬ app (sold seperately). * The wireless LAN interface cannot be used at the same time. External Connect Kit (UTY-XWZXZG) is required for the connection. 46 MULTI-ZONE MINI-SPLITS MULTI-ZONE MINI-SPLIT SYSTEMS lOperate as few as one indoor unit or all indoor units lChoose from 4 indoor unit styles - wall mount, slim duct, compact cassette, and floor mount lMany combinations are ENERGY STAR® qualified lCreate hundreds of combinations based on indoor type and BTUh lConnect 2 to 5 indoor units, depending on model lConnect 14,000 to 54,000 BTUh lNo branch boxes or separation tubes required lConnect 2 to 4 indoor units, depending on model lConnect 14,000 to 39,000 BTU leXtra Low Temp Heating down to -15°F outdoor temps lNo branch boxes or separation tubes required 18, 24, 36,000 BTUh MULTI-ZONE MULTI-ZONE EXTRA LOW TEMPERATURE HEATING 47 MULTI-ZONE AND XLTH SERIES SYSTEMS 18, 24, 36, AND 45,000 BTUh AOU18RLXFZ AOU24RLXFZ AOU36RLXFZ1 AOU45RLXFZ AOU18RLXFZH AOU24RLXFZH AOU36RLXFZH CONNECTABLE CAPACITY This allows connectable indoor units’ total capacity to exceed outdoor unit capacity. See Allowable Combination Table on page 64. If all indoor units are cooling or heating at the same time, the system will limit their capacity so that their total matches the outdoor unit capacity. When a zone meets a desired set temperature it requires less capacity. The unused capacity is then distributed to the remaining indoor units, increasing their capacity. YEAR-ROUND, WHOLE HOME OR BUSINESS COMFORT Halcyon Systems are some of today’s most advanced forms of heating and air conditioning. Multi-zone outdoor units can operate from 2 to 5 indoor units simultaneously. Fujitsu’s systems are super quiet as well as highly energy efficient. FOR EXAMPLE The load on a 3-bedroom home with a living room and kitchen downstairs and 3 bedrooms upstairs is 39,000 BTUh (21,000 BTU downstairs and 18,000 BTU upstairs). However the family isn’t upstairs and downstairs at the same time, therefore not all units will be running simultaneously allowing 100% heating or cooling to occupied spaces. This can be achieved by our AOU36RLXFZ1 outdoor unit. 48 MULTI-ZONE MINI-SPLITS The ability to create the right combinations, the right quantity (up to 5-zones), the right style indoor units, and the right capacity. It’s the RIGHT choice for your home or business. MIX AND MATCH FLEXIBILITY MULTI-ZOME INDOOR UNITSWALL MOUNTS ASU7, 9, 12RLF1  ASU15RLF1  ASU18RLF  ASU24RLF  FLOOR MOUNTS AGU9, 12RLF  AGU15RLF  SLIM DUCTS ARU7, 9, 12RLF  ARU18RLF  ARU24RLF  COMPACT CASSETTES AUU7, 9, 12RLF  AUU18RLF  AOU18RLXFZ AOU18RLXFZH AOU24RLXFZ AOU24RLXFZH AOU36RLXFZ1 AOU36RLXFZH AOU45RLXFZ MULTI-ZONE OUTDOOR UNITS 49 INDIVIDUAL ZONING: PERSONALIZED WHOLE HOME COMFORT FLOOR MOUNTED Floor mount systems are ideal for residential radiator replacements or any room with limited upper wall space, like a kitchen or sunroom. • Compact size fits easily under a standard window • Features twin airflow for improved heat delivery • Designer wireless remote control WALL MOUNTED High wall location for minimized presence. The elimination of ducting increases delivered efficiency. • Quiet operation • Easy maintenance • High delivered efficiency means lower utility bills COMPACT CASSETTE Cassettes are extremely discreet, with only the grille showing in the ceiling. They use the latest fan technology to distribute the conditioned air evenly. • Wired remote control (wireless is optional) • Powerful turbo fan operation • Fits into a standard 2’ x 2’ ceiling grid SLIM DUCT Mounted in a ceiling or in a framed enclosure below a ceiling. They use minimal ductwork and remain very energy efficient. • Concealed and out of sight • Look of central air with the efficiency of a mini-split • Less ducts = higher efficiency MULTI-ZONE MINI-SPLITS 50 MULTI-ZONE MINI-SPLITS BUILT IN FILTRATION LONG-LIFE ION DEODORIZATION FILTER The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. The filter can be used for approximately 3 years if it is washed with water when dirty to restore its surface action. APPLE-CATECHIN FILTER Dust, mold spores and micro-organisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. ASU7, 9, 12, 15RLF1 ASU18, 24RLF 7, 9, 12, 15, 18, 24,000 BTUh WALL MOUNT 1 Economy Minimum Heat Changeover Auto 2 Adjust 4-Way 3 Up/Down 4 Restart Dry Quiet Mode 24 Hour Sleep Weekly 5 Cold Ion Sensor 6 I/O 3rd Party 7 16 Daisy 164+ ft Piping 8 Wi-Fi Capable 9 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 3 RLF models only. 4 RLF1 models only. 5 RLF1 models: Available only with optional wired remote control. 6 Available only with optional wired remote control and optional interface kit. 7 Available only with optional interface kit. 8 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit. 9 See page 13 for details. MULTI-ZONE INDOOR 51 ASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RLF1, ASU18RLF, ASU24RLF ASU7RLF1 ASU9RLF1 ASU12RLF1 ASU15RLF1 ASU18RLF ASU24RLF Performance Nominal Cooling BTUh 7,000 9,000 12,000 14,000 18,000 24,000 Nominal Heating BTUh 8,100 10,200 13,500 16,300 20,000 27,000 Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h) Clg 330 (560) Htg 330 (560) Clg 353 (600) Htg 353 (600) Clg 388 (660) Htg 388 (660) Clg 430 (730) Htg 430 (730) Clg 542 (920) Htg 542 (920) Clg 659 (1,120) Htg 647 (1,100) Medium CFM (m3/h) Clg 294 (500) Htg 294 (500) Clg 306 (520) Htg 306 (520) Clg 330 (560) Htg 330 (560) Clg 353 (600) Htg 362(615) Clg 436 (740) Htg 436 (740) Clg 530 (900) Htg 530 (900) Low CFM (m3/h) Clg 253 (430) Htg 253 (430) Clg 253 (430) Htg 253 (430) Clg 265 (450) Htg 277 (470) Clg 312 (530) Htg 330 (560) Clg 365 (620) Htg 365 (620) Clg 436 (740) Htg 436 (740) Quiet CFM (m3/h) Clg 182 (310) Htg 194 (330) Clg 182 (310) Htg 194 (330) Clg 182 (310) Htg 194 (330) Clg 212 (360) Htg 221 (375) Clg 324 (550) Htg 324 (550) Clg 365 (620) Htg 365 (620) Fan Speed Stage 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)36/36 37/37 40/40 42/42 43/44 49/48 Medium dB(A)32/32 33/33 36/36 38/38 37/37 42/42 Low dB(A)29/29 29/29 30/31 33/35 33/33 37/37 Quiet dB(A)21/22 21/22 21/22 25/27 31/31 33/33 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Current Rated: Cooling Amps 0.13 0.15 0.19 0.25 0.32 0.53 Current Rated: Heating Amps 0.13 0.15 0.19 0.25 0.32 0.53 Inut Power W 15 17 22 28 41 69 Size & Weight Net Weight lbs. (kg) 19 (8.5)19 (8.5)19 (8.5)19 (8.5)31 (14)31 (14) Dimensions: Height Inch 10-1/2 10-1/2 10-1/2 10-1/2 12-5/8 12-5/8 mm 268 268 268 268 320 320 Width Inch 33-1/16 33-1/16 33-1/16 33-1/16 39-1/4 39-1/4 mm 840 840 840 840 998 998 Depth Inch 8 8 8 8 9 9 mm 203 203 203 203 228 228 Refrigerant R410A R410A R410A R410A R410A R410A Additional Data Air Direction: Horizontal Manual Manual Manual Manual Auto Auto Vertical Auto Auto Auto Auto Auto Auto Primary Air Filter Washable Washable Washable Washable Washable Washable Ion Deodorizing Filter Disposable Disposable Disposable Disposable Disposable Disposable Apple-Catechin Filter Disposable Disposable Disposable Disposable Disposable Disposable Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 1/4 52 MULTI-ZONE MINI-SPLITS 7, 9, 12, 18, 24,000 BTUh SLIM DUCT SLIM DUCT Adaptable when ceiling cavity is small and there is no slope for drain. FLEXIBLE INSTALLATION Horizontal or vertical installation. When installed vertically, condensate drain is by gravity only. Drain Pump13” 9.4” Traditional Compact Duct 1 Economy Minimum Heat 2 Changeover Auto 3 Adjust Restart Dry Quiet Mode 24 Hour 2 Sleep 2 We ekly Cold Sensor I/O 3rd Party 4 Pump 16 Daisy 164+ ft Piping 5 Wi-Fi Capable 6 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available only with optional wireless remote control. 3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 4 Availabe lonly with optional interface kit. 5 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit. 6 See page 13 for details. ARU7RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF CFM 323 353 383 554 785 Typical Filter Size 12 x 20 12 x 20 12 x 20 14 x 25 18 x 30 Velocity, FPM 194 212 230 228 209 Unit External SP, in. W.C.0.36 0.36 0.36 0.36 0.20 1” Fiberglass Filter *SP Loss, in. W.C.0.04 0.04 0.05 0.04 0.04 ^Available Static Pressure 0.32 0.32 0.31 0.32 0.16 1” MERV 8 Pleated Filter *SP Loss, in. W.C.0.10 0.12 0.14 0.14 0.12 ^Available Static Pressure 0.26 0.24 0.22 0.22 0.08 2” MERV 8 Pleated Filter *SP Loss, in. W.C.0.06 0.07 0.08 0.08 0.07 ^Available Static Pressure 0.30 0.29 0.28 0.28 0.13 FIELD SUPPLIED FILTERS Filters are sized to keep velocities and static pressure loss low. This will ensure sufficient static pressure is available for ductwork, fittings and supply and return grilles. Alternative filter sizes with equivalent face areas can be used. MULTI-ZONE INDOOR *Typical filter pressure drop. ^Available Static Pressure factors in filter pressure loss only. 53 ARU7RLF, ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF ARU7RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF Performance Nominal Cooling BTUh 7,000 9,000 12,000 18,000 24,000 Nominal Heating BTUh 8,100 10,200 13,500 20,000 27,000 Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)323 (550)353 (600)383 (650)554 (940) 783 (1,330) Medium CFM (m3/h)288 (490)324 (550)353 (600)518 (880)730 (1,240) Low CFM (m3/h)276 (470)294 (500)324 (550)483 (820)648 (1,100) Quiet CFM (m3/h)259 (440)265 (450)283 (480)442 (750)607 (1,030) Fan Speed Stage 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)28/28 28/28 29/29 32/33 33/35 Medium dB(A)26/26 27/26 28/28 31/32 32/34 Low dB(A)25/25 26/25 27/27 30/31 30/32 Quiet dB(A)24/24 25/24 26/24 29/29 29/29 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Static Pressure W. C.0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 0 ~ 0.20 Current Rated: Cooling Amps 0.30 0.30 0.35 0.44 0.66 Current Rated: Heating Amps 0.30 0.30 0.35 0.44 0.66 Input Power W 33 49 58 73 111 Size & Weight Net Weight lbs. (kg) 37 (17)41 (19)41 (19)50 (23)59 (27) Dimensions: Height Inch 7-25/32 7-25/32 7-25/32 7-25/32 7-25/32 mm 198 198 198 198 198 Width Inch 27-9/16 27-9/16 27-9/16 35-7/16 43-5/16 mm 700 700 700 900 1,100 Depth Inch 24-13/32 24-13/32 24-13/32 24-13/32 24-13/32 mm 620 620 620 620 620 Supply Duct Flange Dimensions: Height Inch 5-15/16 5-15/16 5-15/16 5-15/16 5-15/16 mm 151 151 151 151 151 Width Inch 25-19/32 25-19/32 25-19/32 33-15/32 41-11/32 mm 650 650 650 850 1,050 Depth Inch 3/4 3/4 3/4 3/4 3/4 mm 19 19 19 19 19 Return Duct Dimensions: Height Inch 6 6 6 6 6 mm 152 152 152 152 152 Width Inch 22 22 22 30 37-3/4 mm 559 559 559 762 959 Height Inch 3/4 (Flat)3/4 (Flat)3/4 (Flat)3/4 (Flat)3/4 (Flat) mm 19 (Flat)19 (Flat)19 (Flat)19 (Flat)19 (Flat) Refrigerant R410A R410A R410A R410A R410A Additional Data Air Filter Washable Washable Washable Washable Washable Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 Gas 5/8 Liq. 1/4 54 MULTI-ZONE MINI-SPLITS 7, 9, 12, 18,000 BTUh COMPACT CASSETTES 2-STAGE TURBO FAN Air distribution is evenly spread across the heat exchanger by the 2 stage turbo fan which produces two separate airflow streams. Heat exchange efficiency: Increased 20% 1-stage 2-stage Fresh Air Kit UTZ-VXAA Permits limited introduction of outdoor air into the cassette unit for ventilation purposes. Additional items required. (see footnote #4, above) 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details. 2 Available only with optional wireless remote control. 3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 4 Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or 90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the height of the indoor unit. 5 Available only with optional Interface kit. Operation monitoring and On/Off control only. 6 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit. 7 See page 13 for details. 1 Economy Minimum Heat 2 Changeover Auto 3 Adjust Up/Down Restart Dry Fresh 4 Quiet Mode 24 Hour 2 Sleep 2 We ekly Cold Ceiling Sensor I/O 3rd Party 5 Pump 16 Daisy 164+ ft Piping 6 Wi-Fi Capable 7 MULTI-ZONE INDOOR EASY MAINTENANCE Maintenance is made simple by removing the ceiling panel next to the grille. Working on the cassette unit from an adjoining ceiling tile keeps disruption and construction costs down. The air inlet grille can be installed in various directions, making maintenance convenient. QUIET OPERATION Optimization of wing form (laminar wing design) and number of wings (7 blades) enables as low as 27 dB. OPTIONAL ACCESSORY 55 AUU7RLF, AUU9RLF, AUU12RLF, AUU18RLF AUU7RLF AUU9RLF AUU12RLF AUU18RLF Performance Nominal Cooling BTUh 7,000 9,000 12,000 18,000 Nominal Heating BTUh 8,100 10,200 13,500 20,000 Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)318 (540) Clg or Htg 318 (540) Clg or Htg 359 (610) Clg or Htg 441 (750) Clg 471 (800) Htg Medium CFM (m3/h)288 (490) Clg or Htg 288 (490) Clg or Htg 312 (530) Clg or Htg 359 (610) Clg 418 (710) Htg Low CFM (m3/h)259 (440) Clg or Htg 259 (440) Clg or Htg 277 (470) Clg or Htg 306 (520) Clg 353 (600) Htg Quiet CFM (m3/h)230 (390) Clg or Htg 230 (390) Clg or Htg 241 (410) Clg or Htg 241 (410) Clg 265 (450) Htg Fan Speed Stage 4+auto 4+auto 4+auto 4+auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)33/34 33/34 37/37 42/44 Medium dB(A)31/32 31/32 33/33 37/40 Low dB(A)29/29 29/29 31/31 33/37 Quiet dB(A)27/27 27/27 28/28 29/30 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Current Rated: Cooling Amps 0.15 0.15 0.19 0.30 Current Rated: Heating Amps 0.15 0.15 0.19 0.30 Input Power W 18 18 23 39 Size & Weight Net Weight lbs. (kg) 33 (15)33 (15)33 (15)33 (15) Dimensions: Height Inch 9-11/16 9-11/16 9-11/16 9-11/16 mm 245 245 245 245 Width Inch 22-7/16 22-7/16 22-7/16 22-7/16 mm 570 570 570 570 Depth Inch 22-7/16 22-7/16 22-7/16 22-7/16 mm 570 570 570 570 Refrigerant R410A R410A R410A R410A Additional Data Air Direction: Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Front Grille UTG-CCGFG*UTG-CCGFG*UTG-CCGFG*UTG-CCGFG* Grille Dim: Height Inch (mm)1-15/16 (49)1-15/16 (49)1-15/16 (49)1-15/16 (49) Width Inch (mm)24-7/16 (620)24-7/16 (620)24-7/16 (620)24-7/16 (620) Depth Inch (mm)24-7/16 (620)24-7/16 (620)24-7/16 (620)24-7/16 (620) Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 * Compact Cassette Grille UTG-CCGFG sold separately. Must order one with each compact cassette. MULTI-ZONE MINI-SPLITS 56 2-FAN AND WIDE AIRFLOW Having both upper and lower airflow quickly warms or cools the entire room. Floor mount can be set in “Upward Airflow Only” when occupants wish not to have feet warmed or cooled. FLEXIBLE AND EASY INSTALLATION 9, 12, 15,000 BTUh FLOOR MOUNT 1 Economy Minimum Heat Changeover Auto Adjust Up/Down Restart Dry Powerful Quiet Mode 24 Hour Sleep Weekly 2 Cold Ion Sensor 2 I/O 3rd Party 3 16 Daisy 2 Wi-Fi Capable 4 1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 2 Available with optional wired remote control. 3 Available only with optional Interface kit. Operation monitoring and On/Off control only. 4 See page 13 for details. Beneath standard window 27- 9/16” 23- 5/8” 29-1/8” 7-7/8” Standard concave portion Min. 27- 9/16” Min. 37” Wall Max. 5-7/8” Half concealed* Min. 23- 1/4” Min. 28-3/4” Max. 3-1/8” * Field supplied insulation required Cooling Heating Window Fig. 1 Fig. 2 Fig. 1 Fig. 2 1. Upon startup, both top and bottom louvers open. 2. As the room temperature nears the setpoint, only the top louver stays open to help prevent cold air from falling. 1. Upon startup, both top and bottom louvers open. 2. Closer to setpoint, only the top louver stays open to help prevent cold drafts from windows. MULTI-ZONE MINI-SPLITS MULTI-ZONE INDOOR 57 AGU9RLF, AGU12RLF, AGU15RLF AGU9RLF AGU12RLF AGU15RLF Performance Nominal Cooling BTUh 9,000 12,000 14,200 Nominal Heating BTUh 12,000 16,000 18,000 Fan (Cooling Mode) Air Circulation: Hi CFM (m3/h)312 (530)353 (600)383 (650) Medium CFM (m3/h)259 (440)288 (490)306 (520) Low CFM (m3/h)212 (360)224 (380)235 (400) Quiet CFM (m3/h)159 (270)159 (270)159 (270) Fan Speed Stage 4+Auto 4+Auto 4+Auto Sound Indoor Sound Level (Clg/Htg): Hi dB(A)39/39 42/42 44/44 Medium dB(A)34/34 36/38 38/39 Low dB(A)28/28 30/32 31/33 Quiet dB(A)22/22 22/22 22/22 Electrical Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 Current Rated: Cooling Amps 0.15 0.18 0.20 Current Rated: Heating Amps 0.15 0.18 0.20 Input Power W 16 18 23 Size & Weight Net Weight lbs. (kg) 31 (14)31 (14)31 (14) Dimensions: Height Inch 23-5/8 23-5/8 23-5/8 mm 600 600 600 Width Inch 29-1/8 29-1/8 29-1/8 mm 740 740 740 Depth Inch 7-7/8 7-7/8 7-7/8 mm 200 200 200 Refrigerant R410A R410A R410A Additional Data Air Direction: Horizontal Manual Manual Manual Air Direction: Vertical Auto Auto Auto Apple Catechin Filter Washable Washable Washable Ion Deoderizing Filter Yes Yes Yes Connection Method Yes Yes Yes Lineset Size Inch Gas 3/8 Liq. 1/4 Gas 3/8 Liq. 1/4 Gas 1/2 Liq. 1/4 58 FEATURES MULTI-ZONE MINI-SPLITS AOU36RLXFZ1AOU18, 24RLXFZ COMPACT SIZE The compact size of the outdoor units allows for many installation opportunities. AOU45RLXFZ 18, 24, 36, 45,000 BTUh MULTI-ZONE OUTDOOR UNITS Contractors can select either an 18, 24, 36 or 45,000 BTU outdoor unit combined with wall mounted, slim duct, compact cassette or floor mount type indoor units. Mix- and-match flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. These systems are ideal for nursing homes, doctor’s offices, condominiums, apartments and residences - any place where individual cooling or heating is needed. DC TWIN ROTARY COMPRESSOR A high performance, low noise, large capacity DC twin rotary compressor is used. OUTDOOR UNIT INDOOR UNIT TYPE Non-ducted Ducted Mixed AOU18RLXFZ –––– AOU24RLXFZ –––– AOU36RLXFZ1 –––––– AOU45RLXFZ –––––– ENERGY STAR® QUALIFYING SYSTEMS: SERVICE VALVES AOU18RLXFZ / AOU24RLXFZ / AOU36RLXFZ1 The above units have (2) service valves for each zone. BENEFITS: • Installation – Allows for reduced installation time. • Service – Allows for refrigerant isolation of each zone, if necessary. • Add Ons – Ease of additional add-ons. The AOU45RLXFZ does not have this feature. 59 AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ1, AOU45RLXFZ Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. AOU18RLXFZ ASU9+ASU9 AOU24RLXFZ ASU9+ASU7+ASU7 AOU36RLXFZ1 ASU9 x 4 AOU45RLXFZ ASU9 x 5 Performance Connectable Indoor Units 2 2 to 3 2* to 4 2 to 5 Connectable Unit Capacity Class BTUh 14 to 21,0001 14 to 27,0001 27 to 39,0001 34 to 54,000 Rated Capacity Cooling / Heating BTUh 18,000 / 22,000 22,000 / 24,000 35,200 / 36,400 45,000 / 48,000 Cooling Operating Range °F (°C) 14~115 (-10~46) 14~115 (-10~46) 14~115 (-10~46) 14~115 (-10~46) Heating Operating Range °F (°C) 5~75 (-15~24) 5~75 (-15~24) 5~75 (-15~24) 5~75 (-15~24) Electrical Rated Input Power Clg/Htg kW 1.44/1.87 1.76/1.73 3.52/3.00 4.28/3.88 Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Maximum Total Current Amps 10.0 13.7 20.3 23.8 Minimum Circuit Ampacity Amps 12.1 16.7 24.6 28.9 Maximum Circuit Breaker Amps 15 20 30 30 Fan: Type x Quantity Propeller x 1 Propeller x 1 Propeller x 1 Propeller x 1 Sound Pressure Level Cooling dB(A)49 51 53 53 Sound Pressure Level Heating dB(A)49 52 55 55 Lineset Requirements Minimum Lineset Length Each ft(m)16 (5)16 (5)16 (5)16 (5) Maximum Lineset Length Each ft(m)82 (25)82 (25)82 (25)82 (25) Minimum Lineset Length Total ft(m)49 (15)49 (15)66 (20)49 (15) Maximum Lineset Length Total ft(m)164 (50)164 (50)230 (70)264 (80) Pre-Charge Length Total ft(m)98 (30)98 (30)164 (50)164 (50) Maximum Lineset Height Difference Btwn Outdoor Unit & Furthest Indoor Unit ft(m)49 (15)49 (15)49 (15)49 (15) Maximum Lineset Height Difference Btwn Indoor Units ft(m)33 (10)33 (10)33 (10)33 (10) Lineset Diameter Inch Liq. 1/4 x 2 Gas 3/8 x 2 Liq. 1/4 x 3 Gas 1/2 x 1, 3/8 x 2 Liq. 1/4 x 4 Gas 1/2 x 1, 3/8 x 3 Liq. 1/4 x 5 Gas 1/2 x 2, 3/8 x 3 Size & Weight Net Weight lbs. (kg) 119 (54)124 (56)149 (68)205 (93) Dimensions: Height Inch 27-9/16 27-9/16 32-11/16 39-5/16 mm 700 700 830 998 Width Inch 35-7/16 35-7/16 35-7/16 38-3/16 mm 900 900 900 970 Depth Inch 13 13 13 14-9/16 mm 330 330 330 370 Refrigerant R410A R410A R410A R410A *18+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818 1See table for allowed combinations within this connectable capacity range. 60 MULTI-ZONE MINI-SPLITS Base Drainage Holes The contoured base design discharges melted water through many holes located at the bottom of the unit. AMBIENT HEATING TEMPERATURE OF -15°F Other models may go as low as -5°F, however they do not include a base heater and other advancements found in XLTH models. See the full story on page 14. The base of Fujitsu’s XLTH outdoor condensing units.IMPROVED HEATING CAPACITY Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor. 18, 24,000 BTUh 36,000 BTUh 18, 24, 36,000 BTUh XLTH MULTI-ZONE OUTDOOR UNITS Base Heater When temperatures reach 36°F, a built-in heater warms the base of the outdoor unit so that condensation doesn’t freeze. Without a heater, freezing condensate can cause noise, damage to the fan blade, condenser, and system performance.% of Heating CapacityAmbient Te mperature (F°) 50 100 47 5 -15 RLXFZ (Standard Multi-Zone) “H” Series Models OUTDOOR UNIT INDOOR UNIT TYPE Non-ducted Ducted Mixed AOU18RLXFZH –– AOU24RLXFZH –– AOU36RLXFZH –– ENERGY STAR® QUALIFYING SYSTEMS: SERVICE VALVES AOU18RLXFZH / AOU24RLXFZH The above units have (2) service valves for each zone. BENEFITS: • Installation – Allows for reduced installation time. • Service – Allows for refrigerant isolation of each zone, if necessary. • Add Ons – Ease of additional add-ons. The AOU36RLXFZH does not have this feature. 61 HIGH-HEAT AOU18RLXFZH, AOU24RLXFZH, AOU36RLXFZH Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. AOU18RLXFZH ASU9+ASU9 AOU24RLXFZH ASU9+ASU7+ASU7 AOU36RLXFZH ASU9 x 4 Performance Connectable Indoor Units 2 2 to 3 2 to 4 Connectable Unit Capacity Class BTUh 14,000 to 21,000 14,000 to 27,000 27,000 to 39,000 Rated Capacity Cooling/Heating BTUh 18,000/22,000 22,000/25,000 35,200/36,400 Cooling Operating Range °F (°C) 14 to 115 (-10 to 46) 14~115 (-10~46) 14~ 115 (-10~46) Heating Operating Range °F (°C) -15 to 75 (-26 to 24) -15~75 (-26~24) -15~75 (-26~24) Electrical Rated Input Power Clg/Htg kW 1.33/1.70 1.65/1.81 2.70/2.67 Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 Maximum Total Current Amps 16.4 20.8 26.0 Minimum Circuit Ampacity Amps 19.7 25.1 31.5 Maximum Circuit Breaker Amps 20 30 40 Fan: Type x Quantity Propeller x 1 Propeller x 1 Propeller x 1 Sound Pressure Level Cooling dB(A)48 50 53 Sound Pressure Level Heating dB(A)50 52 55 Lineset Requirements Minimum Lineset Length Each ft(m)16 (5)16 (5)16 (5) Maximum Lineset Length Each ft(m)82 (25)82 (25)82 (25) Minimum Lineset Length Total ft(m)49 (15)49 (15)49 (15) Maximum Lineset Length Total ft(m)164 (50)230 (70)230 (70) Pre-Charge Length Total ft(m)98 (30)98 (30)164 (50) Maximum Lineset Height Difference Btwn Outdoor Unit & Furthest Indoor Unit ft(m)49 (15)49 (15)49 (15) Maximum Lineset Height Difference Btwn Indoor Units ft(m)33 (10)33 (10)33 (10) Lineset Diameter Inch Liq. 1/4 x 2 Gas 3/8 x 2 Liq. 1/4 x 3 Gas 1/2 x 1, 3/8 x 2 Liq. 1/4 x 4 Gas 1/2 x 1, 3/8 x 3 Size & Weight Net Weight lbs. (kg) 134 (61)146 (66)205 (93) Dimensions: Height Inch 32-11/16 32-11/16 39-5/16 mm 830 830 998 Width Inch 35-7/16 35-7/16 38-3/16 mm 900 900 970 Depth Inch 13 13 14-9/16 mm 330 330 370 Refrigerant R410A R410A R410A 62 MULTI-ZONE MINI-SPLITS CASSETTE FLOOR MOUNT AOU45RLXFZ 63 Cool or heat one room, a few rooms or an entire home. lConnect 2 to 5 indoor units l58 to 120% connectable capacity lConnect 14,000 to 54,000 total BTUh SLIM DUCT WALL MOUNT WHOLE HOME SOLUTIONS 18, 24, 36, 45,000 BTUH OUTDOOR HEAT PUMPS 64 MULTI-ZONE MINI-SPLITS “+” represents available circuit for future expansion when connecting this combination. * The optional kit “K9FZ1818 (UTP-MU36A2)” is necessary for dual zone system “18+18” with AOU36RLXFZ1 only. ^ Wall mounted type ASU18RLF cannot be connected in this combination using AOU36RLXFZ1. Combination allowed with AOU36RLXFZH. ◊ Actual rated cooling capacity of ASU15RLF1 is 14,000 BTU/h. Do not use combination table for system capacity calculations. AOU18RLXFZ / AOU18RLXFZH ZONE 1 ZONE 2 TOTAL 7 7 14 7 9 16 7 12 19 9 9 18 9 12 21 AOU24RLXFZ / AOU24RLXFZH ZONE 1 ZONE 2 ZONE 3 TOTAL 7 7 +14 7 9 +16 7 12 +19 7 15 22 7 18 25 9 9 +18 9 12 21 9 15 24 9 18 27 12 12 24 12 15 27 7 7 7 21 7 7 9 23 7 7 12 26 7 9 9 25 9 9 9 27 AOU36RLXFZH ZONE 1 ZONE 2 TOTAL 7 24 31 9 24 33 12 24 36 15 24 39 AOU36RLXFZ1 / AOU36RLXFZH ZONE 1 ZONE 2 ZONE 3 ZONE 4 TOTAL 18*18*36 7 7 15 +29 7 7 18 +32 7 7 24 38 7 9 12 +28 7 9 15 +31 7 9 18 34 7 12 12 +31 7 12 15 34 7 12 18 37 9 9 9 +27 9 9 12 +30 9 9 15 33 9 9 18 36 9 12 12 33 9 12 15 36 9 12 18 39 12 12 12 36 12 12 15 39 7 7 7 7 28 7 7 7 9 30 7 7 7 12 33 7 7 7 15 36 7 7 7 18^39 7 7 9 9 32 7 7 9 12 35 7 7 9 15 38 7 7 12 12 38 7 9 9 9 34 7 9 9 12 37 9 9 9 9 36 9 9 9 12 39 CHOOSE AN OUTDOOR UNIT: Select either an 18, 24, 36 or 45,000 BTUh outdoor unit combined with wall mounted, slim duct, compact cassette or floor mount type indoor units. Mix-and-match flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. AOU18RLXFZ AOU18RLXFZH Connect 2 indoor units AOU24RLXFZ AOU24RLXFZH Connect 2-3 indoor units AOU36RLXFZ1 AOU36RLXFZH Connect 2-4 indoor units ALLOWABLE COMBINATIONS CHOOSE INDOOR UNITS: AUU7RLF AUU9RLF AUU12RLF AUU18RLF AGU9RLF AGU12RLF AGU15RLF ASU7RLF1 ASU9RLF1 ASU12RLF1 ASU15RLF1◊ ASU18RLF ASU24RLF ARU7RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF = Allowed “Connectable Capacity” combinations over 100% ** NOTE: These tables are not for system capacity selection. Fujitsu ‘Design Simulator’ software can be used for Halcyon equipment selection 65 AOU45RLXFZ ZONE 1 ZONE 2 TOTAL 18 18 36 12 24 36 15 24 39 18 24 42 24 24 48 AOU45RLXFZ, con’t ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 TOTAL 7 7 7 7 7 35 7 7 7 7 9 37 7 7 7 7 12 40 7 7 7 7 15 43 7 7 7 7 18 46 7 7 7 7 24 52 7 7 7 9 9 39 7 7 7 9 12 42 7 7 7 9 15 45 7 7 7 9 18 48 7 7 7 9 24 54 7 7 7 12 12 45 7 7 7 12 15 48 7 7 7 12 18 51 7 7 7 15 15 51 7 7 7 15 18 54 7 7 9 9 9 41 7 7 9 9 12 44 7 7 9 9 15 47 7 7 9 9 18 50 7 7 9 12 12 47 7 7 9 12 15 50 7 7 9 12 18 53 7 7 9 15 15 53 7 7 12 12 12 50 7 7 12 12 15 53 7 9 9 9 9 43 7 9 9 9 12 46 7 9 9 9 15 49 7 9 9 9 18 52 7 9 9 12 12 49 7 9 9 12 15 52 7 9 12 12 12 52 9 9 9 9 9 45 9 9 9 9 12 48 9 9 9 9 15 51 9 9 9 9 18 54 9 9 9 12 12 51 9 9 9 12 15 54 9 9 12 12 12 54 ZONE 1 ZONE 2 ZONE 3 TOTAL 7 7 24 38 7 9 18 34 7 9 24 40 7 12 18 37 7 12 24 43 7 15 15 37 7 15 18 40 7 15 24 46 7 18 18 43 7 18 24 49 9 9 18 36 9 9 24 42 9 12 15 36 9 12 18 39 9 12 24 45 9 15 15 39 9 15 18 42 9 15 24 48 9 18 18 45 9 18 24 51 12 12 12 36 12 12 15 39 12 12 18 42 12 12 24 48 12 15 15 42 12 15 18 45 12 15 24 51 12 18 18 48 12 18 24 54 15 15 15 45 15 15 18 48 15 15 24 54 15 18 18 51 18 18 18 54 AOU45RLXFZ, con’t ZONE 1 ZONE 2 ZONE 3 ZONE 4 TOTAL 7 7 7 15 36 7 7 7 18 39 7 7 7 24 45 7 7 9 12 35 7 7 9 15 38 7 7 9 18 41 7 7 9 24 47 7 7 12 12 38 7 7 12 15 41 7 7 12 18 44 7 7 12 24 50 7 7 15 15 44 7 7 15 18 47 7 7 15 24 53 7 7 18 18 50 7 9 9 9 34 7 9 9 12 37 7 9 9 15 40 7 9 9 18 43 7 9 9 24 49 7 9 12 12 40 7 9 12 15 43 7 9 12 18 46 7 9 12 24 52 7 9 15 15 46 7 9 15 18 49 7 9 18 18 52 7 12 12 12 43 7 12 12 15 46 7 12 12 18 49 7 12 15 15 49 7 12 15 18 52 7 15 15 15 52 9 9 9 9 36 9 9 9 12 39 9 9 9 15 42 9 9 9 18 45 9 9 9 24 51 9 9 12 12 42 9 9 12 15 45 9 9 12 18 48 9 9 12 24 54 9 9 15 15 48 9 9 15 18 51 9 9 18 18 54 9 12 12 12 45 9 12 12 15 48 9 12 12 18 51 9 12 15 15 51 9 12 15 18 54 12 12 12 12 48 12 12 12 15 51 12 12 12 18 54 12 12 15 15 54 AOU45RLXFZ Connect 2-5 indoor units = Allowed “Connectable Capacity” combinations over 100% ** ** Exceeding 100% capacity match will not increase system output capacity NOTE: These tables are not for system capacity selection. Fujitsu ‘Design Simulator’ software can be used for Halcyon equipment selection FEATURES 66 ACCESSORIES 1 If using UTY-RNBYU with these models you need to change the dip switch SW-1 to “ON”. Refer to Tech Tip #028. 2 Requires accessory interface kit #UTY-TWRXZ2 in order to connect these devices to IDU. 3 Wall mounted ASU7, 9, 12RLF1 and ASU15RLF1 require accessory interface kit #UTY-XCBXZ2 in order to connect these devices to them. ACCESSORY COMPATIBILITY SINGLE-ZONE SYSTEMS SINGLE-ZONE SYSTEMS MULTI-ZONE AND FLEX-ZONE SYSTEMSWALL MOUNTED FLOOR MOUNT COMPACT CASSETTE SLIM DUCT MEDIUM STATIC DUCTED MP AHU UNIVERSAL FLOOR / CEILING CIRCULAR FLOW LARGE CASSETTE 9RL209LMAS109LMAH109LZAS109LZAH112RL212LMAS112LMAH112LZAS112LZAH115LZAS115LZAH118RLB18RLXFW118RLXFWH24RLB24RLXFW124RLXFWH30RLXB30RLXEH36RLXB9RLFF9RLFFH12RLFF12RLFFH15RLFF15RLFFH9RLFCC12RLFCC18RLFCC9RLFCD12RLFCD18RLFCD12RGLXD18RGLXD24RGLXD30RGLXD36RGLXD42RGLXD48RGLXD24LRGLXM30LRGLXM36LMAS148LMAS118RULX24RULX36RSLX18RGLXC24RGLXC30RGLXC36RGLXC42RGLXC48RGLXCCompact Wall ( 7, 9, 12, 15RLF1)Large Wall (18, 24RLF)CassetteSlim DuctFloor Mount REMOTE CONTROLS UTY-RNBYU Wired Remote Control l1 l1 l1 UTY-RNNUM Wired Remote Control l l l l l l l l l l l l l l l l l l l l l l3 l l l l UTY-RVNUM Wired Remote Control (Backlit)l l l l l l l l l l l l l l l l l l l l l l3 l l l l UTY-RSNUM Simple Remote Control 3-Wire l l l l l l l l l l l l l l l l l l l l l l3 l l l l UTY-RSRY Simple Remote Control 2-Wire l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l l l l l l l l l l l l l l l l l l UTY-RHRY Simple Remote Control 2-Wire l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l l l l l l l l l l l l l l l l l l UTY-LNHUM Wireless Remote Control l l l l UTY-RNRUZ Series Wired Remote Control l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l l l l l l l l l l l l l l l l l l UTY-XSZX Remote Sensor l l l l l l l l l l l l l l l UTY-LRHUM Receiver Unit l l l l UTY-LBTUM IR receiver kit w/ wireless remote controller l l l l l l l l l l l UTY-LBTUC IR receiver kit w/ wireless remote controller l l l l l l WI-FI DEVICES FJ-IR-WIFI-1NA Wi-Fi Device: IR Wireless Module l l l l l l l l l l l l l l l l l l l l l6 l6 l6 l l l l l l l6 l FJ-RC-WIFI-1NA Wi-Fi Device: Wired Module l5 l5 l5 l5 l5 l5 l5 l l5 l5 l5 l5 l5 l5 l5 l l l l l l l l l l3,5 l5 l l l5 FJ-AC-WIFI-1 Wi-Fi Device: Wired Module l l l4 l4 l l l4 l4 l4 l4 l l l l l l l l l l l l l l l l l l UTY-TFNXZ2 Wi-Fi Interface Module l l l l l l l l l l l l l l l l l l l l l l3 l l l l UTY-TFSXZ2 Wi-Fi Interface Module l l l l l l l l l l l l l l l l l l UTY-TFSXF1 Wi-Fi Interface Module l l l l INTERFACE KITS UTY-XWZX Dry Contact Wire Kit l l l l l l l l l l l l l l UTY-XWZXZ5 Dry Contact Wire Kit l l l l l l l l l l l l l l l l l3 l UTY-XWZXZG External Connect Kit l l l l l l l l l l l l l UTY-XWZXZJ External Connect Kit l l l l UTY-XCBXZ2 Interface Kit3 l UTY-TWRXZ2 Interface Kit2 l l l l l l l l l l UTD-ECS5A Slim Duct Connector Kit l l l l UTY-XWZXZ3 Outdoor Unit Input/Output Connector l l l l l UTY-XCSXZ1 External input and output PCB l UTY-XCSXZ2 External input and output PCB l l l4 l4 l l l4 l4 l4 l4 UTZ-GXXB Interface Kit Box l UTY-XCSX External input and output PCB l l l l l l l l l l l l l l l l l UTZ-GXRA External input and output PCB box l l l l l l l l l l UTZ-GXNA External input and output PCB bracket l l l l l l l UTY-SHZXC Human Sensor Kit l l l l l l FRESH AIR INTAKE KITS UTZ-KXGC High Humidity Insulation Kit l l l l UTR-YDZB Air Outlet Shutter Plate l l l l UTZ-VXAA Fresh Air Intake Kit l l l l UTZ-VXRA Fresh Air Kit l l l l l l KHRS940-25 Fresh Air Intake l l l l l l l l l UTR-YDZK Air Outlet Shutter Plate l l l l l l MISCELLANEOUS FJ-AC-BAC-1L BACnet Gateway l l l4 l4 l l l4 l4 l4 l4 l l l l l l l l l l l l l l l l l l FJ-RC-MBS-1 Modbus Module l5 l5 l5 l5 l5 l5 l5 l l5 l5 l5 l5 l5 l5 l5 l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 UTY-VMSX Modbus Gateway l l l4 l4 l l l4 l4 l4 l4 l l l l l l l l l l l l l l l l l UTY-TERX External Switch Controller l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l5 l5 l5 l5 l5 l5 l5 l l5 l5 l5 l5 l5 l5 l5 l l l l l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 UTY-TTRX Thermostat Converter l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l5 l5 l5 l5 l5 l5 l5 l l5 l5 l5 l5 l5 l5 l5 l l l l l l l l l l l l l l l l l l l l3,5 l l l l5 UTY-VTGX Network Converter l2 l2 l2 l2 l2 l2 l2 l2 l2 l2 l5 l5 l5 l5 l5 l5 l5 l l5 l5 l5 l5 l5 l5 l5 l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 K9R410A55 R410A Swivel Adapter l l l l UTD-GXS(A/B/C)-W Auto Louver Grille Kit7 A A B l7 UTD-GXT(A/B/C)-W Auto Louver Grille Kit7 A A B l7 674 Requires the removal of built-in WIFI module. 5 Requires UTY-WIFI. 6 Wireless Receiver #UTY-LRHUM is required in order to connect this device. 7 A: for ARU9, 12. B: for ARU18. C: for ARU24. ACCESSORY COMPATIBILITY SINGLE-ZONE SYSTEMS SINGLE-ZONE SYSTEMS MULTI-ZONE AND FLEX-ZONE SYSTEMSWALL MOUNTEDFLOOR MOUNT COMPACT CASSETTE SLIM DUCT MEDIUM STATIC DUCTED MP AHU UNIVERSAL FLOOR / CEILING CIRCULAR FLOW LARGE CASSETTE 9RL209LMAS109LMAH109LZAS109LZAH112RL212LMAS112LMAH112LZAS112LZAH115LZAS115LZAH118RLB18RLXFW118RLXFWH24RLB24RLXFW124RLXFWH30RLXB30RLXEH36RLXB9RLFF9RLFFH12RLFF12RLFFH15RLFF15RLFFH9RLFCC12RLFCC18RLFCC9RLFCD12RLFCD18RLFCD12RGLXD18RGLXD24RGLXD30RGLXD36RGLXD42RGLXD48RGLXD24LRGLXM30LRGLXM36LMAS148LMAS118RULX24RULX36RSLX18RGLXC24RGLXC30RGLXC36RGLXC42RGLXC48RGLXCCompact Wall ( 7, 9, 12, 15RLF1)Large Wall (18, 24RLF)CassetteSlim DuctFloor Mount REMOTE CONTROLS UTY-RNBYUWired Remote Control l1 l1 l1 UTY-RNNUMWired Remote Controllllllllllllllll l l l l l l l3 l l l l UTY-RVNUMWired Remote Control (Backlit)lllllllllllllll l l l l l l l3 l l l l UTY-RSNUMSimple Remote Control 3-Wirelllllllllllllll l l l l l l l3 l l l l UTY-RSRYSimple Remote Control 2-Wirel2l2l2l2l2l2l2l2l2l2l l l l l l l l l l l l l l l l l l UTY-RHRYSimple Remote Control 2-Wirel2l2l2l2l2l2l2l2l2l2l l l l l l l l l l l l l l l l l l UTY-LNHUMWireless Remote Control l l l l UTY-RNRUZ SeriesWired Remote Control l2l2l2l2l2l2l2l2l2l2l l l l l l l l l l l l l l l l l l UTY-XSZXRemote Sensor l l l l l l l l l l l l l l l UTY-LRHUMReceiver Unit l l l l UTY-LBTUMIR receiver kit w/ wireless remote controller l l l l l l l l l l l UTY-LBTUCIR receiver kit w/ wireless remote controller l l l l l l WI-FI DEVICES FJ-IR-WIFI-1NA Wi-Fi Device: IR Wireless Module lllllllllllllllll l l l l6 l6 l6 l l l l l l l6 l FJ-RC-WIFI-1NAWi-Fi Device: Wired Module l5l5l5l5l5l5l5ll5l5l5l5l5l5l5 l l l l l l l l l l3,5 l5 l l l5 FJ-AC-WIFI-1Wi-Fi Device: Wired Modulelll4l4lll4l4l4l4l l l l l l l l l l l l l l l l l l UTY-TFNXZ2Wi-Fi Interface Modulelllllllllllllll l l l l l l l3 l l l l UTY-TFSXZ2Wi-Fi Interface Modulel l l l l l l l l l l l l l l l l l UTY-TFSXF1Wi-Fi Interface Modulellll INTERFACE KITS UTY-XWZXDry Contact Wire Kitlllllllll l l l l l UTY-XWZXZ5Dry Contact Wire Kitllllllllllllllll l3 l UTY-XWZXZGExternal Connect Kit l l l l l l l l l l l l l UTY-XWZXZJExternal Connect Kit l l l l UTY-XCBXZ2Interface Kit3 l UTY-TWRXZ2Interface Kit2llllllllll UTD-ECS5ASlim Duct Connector Kit l l l l UTY-XWZXZ3Outdoor Unit Input/Output Connectorl l l l l UTY-XCSXZ1External input and output PCBl UTY-XCSXZ2 External input and output PCBlll4l4lll4l4l4l4 UTZ-GXXBInterface Kit Boxl UTY-XCSXExternal input and output PCB l l l l l l l l l l l l l l l l l UTZ-GXRAExternal input and output PCB box l l l l l l l l l l UTZ-GXNAExternal input and output PCB bracket l l l l l l l UTY-SHZXCHuman Sensor Kit l l l l l l FRESH AIR INTAKE KITS UTZ-KXGCHigh Humidity Insulation Kit l l l l UTR-YDZB Air Outlet Shutter Plate l l l l UTZ-VXAAFresh Air Intake Kit l l l l UTZ-VXRAFresh Air Kit l l l l l l KHRS940-25Fresh Air Intake l l l l l l l l l UTR-YDZK Air Outlet Shutter Plate l l l l l l MISCELLANEOUS FJ-AC-BAC-1LBACnet Gatewaylll4l4lll4l4l4l4l l l l l l l l l l l l l l l l l l FJ-RC-MBS-1Modbus Modulel5l5l5l5l5l5l5ll5l5l5l5l5l5l5 l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 UTY-VMSXModbus Gatewaylll4l4lll4l4l4l4 l l l l l l l l l l l l l l l l l UTY-TERXExternal Switch Controllerl2l2l2l2l2l2l2l2l2l2l5l5l5l5l5l5l5ll5l5l5l5l5l5l5 l l l l l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 UTY-TTRXThermostat Converterl2l2l2l2l2l2l2l2l2l2l5l5l5l5l5l5l5ll5l5l5l5l5l5l5 l l l l l l l l l l l l l l l l l l l l3,5 l l l l5 UTY-VTGXNetwork Converterl2l2l2l2l2l2l2l2l2l2l5l5l5l5l5l5l5ll5l5l5l5l5l5l5 l l l l l l l l l l l l l l l l l l l l3,5 l5 l l l5 K9R410A55 R410A Swivel Adapter l l l l UTD-GXS(A/B/C)-WAuto Louver Grille Kit7 A A B l7 UTD-GXT(A/B/C)-WAuto Louver Grille Kit7 A A B l7 68 WHAT IS AIRZONE? Airzone is an intelligent, communicating zoning system for Halcyon and Airstage ducted indoor units, featuring proportional, modulating dampers. Additional ductless and ducted single zone systems may be integrated for total HVAC control. HOW DOES IT WORK? All Airzone dampers and optional Zone Modules are connected by a 4-wire cable, for power and communication. Dampers are positioned to provide optimum airflow into a zone based upon demand. The indoor unit fan is adjusted to meet the instantaneous sum of all calling zones. CONNECTION DIAGRAM Halcyon Outdoor Unit Fujitsu Wall Mounted Control Wired or Wireless Smart Controllers Halcyon Outdoor Units Halcyon Indoor Units Halcyon Ducted Indoor Unit Modulating Dampers Control Board AZVAFR2FU2 Zone Modules AZVAFDAMPER10R AZVAFDAMPER10C AZVAFDAMPER06C AZVAFZMFU2C AZVAFZMFU2R AZVAFTHINKCB AZVAFTHINKRB AZVAFBLUEFACECB AZVAFTHINKRBAZVAFBLUEFACECB BENEFITS • An Airzone system can provide precisely delivered airflow into each zone, thus reducing excess equipment capacity. • Provides ideal temperature control of each zone in your home or office. • Built in communication gateways maximize Fujitsu Heat Pump inverter efficiency. • Integrate single zone systems with the ducted, modulating damper system. • Modulating dampers and proportional fan control eliminates the need for a bypass duct! FEATURES • Control and monitor up to 10 individual zones. • Adjustable minimum and maximum damper positions. • Control of optional auxiliary heat of the ducted, zoned unit. • Blueface Principal controller provides simple, single point temperature management of ALL zones! • Wired and wireless dampers available. Size ranges from 6” to 14” in diameter. • Flexible control up to 10 hyrdonic zones, as either primary or auxiliary heat. • Flexible integration of modulating dampers and single zone units, with optional hydronic heating zones. Compatible with most Halcyon and Airstage, 2-wire and 3-wire single zone systems. Airzone VAF 8” Wireless Intelligent Round Damper (AZVAFDAMPER08R) Airzone VAF 8” Wired Intelligent Round Damper (AZVAFDAMPER08C) Airzone VAF Control Board with Fujitsu UART Communication Region 2 (AZVAFR2FU2) Airzone VAF Wired Blueface Principal Controller White (AZVAFBLUEFACECB) (diagram for illustration purposes only) ACCESSORIES 69 ^ Minimum Heat, Sleep Timer functions will be lost when the wired remote control is installed. * Wall mounted ASU7, 9, and 12RLF1 require accessory interface kit (Part UTY-XCBXZ2) in order to connect this device to them. Wired Remote Control UTY-RNNUM* UTY-RNBYU^ 3-Wire The wired remote control with its unique lock function and sleek design provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. Wired Remote Control UTY-RVNUM 3-Wire Features a large backlit LCD display and displays the room temperature. Provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. Simple Remote Control UTY-RSNUM 3-Wire Suitable when only basic operations are required for hotels, offices and other places where there is frequent arrival and departure of occupants. Remote does not allow any timer settings. Simple Remote Control 2-Wire UTY-RSRY Backlit 2-wire remote with built in temperature sensor. Offers set point adjustment in 1˚F increments. Concentrates on basic functions such as Start/Stop, fan control, temperature setting and operation mode. Simple Remote Control 2-Wire UTY-RHRY Backlit 2-wire remote with built in temperature sensor. Offers set point adjustment in 1˚F increments. Concentrates on basic functions such as Start/Stop, fan control, and temperature setting. Wired Remote (Touch Panel) UTY-RNRUZ Series 2-Wire Features a large backlit LCD display and displays the room temperature. Provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. Wireless Remote Control UTY-LNHUM For spaces where there is just no place to mount the wired remote or where wireless operation is preferred. Central Controller UTY-DMMUM 3-Wire This remote controls up to 5 individual indoor units. Set temperatures on timers to best meet individuals needs. Includes a large backlit LCD and 4-way navigation pad. Remote connects in daisy chain to branch boxes. Remote Sensor UTY-XSZX Wall mounted room temperature sensor for slim duct models. Replaces room temperature sensor in the return when installed while still allowing for temperature correction. Receiver Kit UTY-LRHUM 3-Wire For slim duct models. Includes a wireless remote control. IR Receiver Kit UTY-LBTUM For medium static ducted units. Includes a wireless remote control. IR Receiver Kit UTY-LBTUC For large circular flow cassettes. Includes a wireless remote control. Group Control: With this feature, multiple evaporators can be ‘daisy-chained’ together on one single remote control. With multiple, single zone systems, Group Control provides the ability of all indoor units to be operated from a single remote control. Group Control may be used on a single, multizone system, however multiple, multizone system indoor units cannot be grouped together. Single and multizone systems cannot be combined for a single Group Control. For additional information, see Engineering Bulletin # 036 and/or 037. CONTROLS Group ControlGroup ControlGroup Control Group Control Group Control Wireless Remote Controller IR Receiver Unit IR Receiver Unit Duct type indoor unit Wireless Remote Controller IR Receiver Unit Duct type indoor unit Wireless Remote Controller Group Control 70 ACCESSORIES WI-FI DEVICES See compatability table, page 13. IR Wireless Module Model: FJ-IR-WIFI-1NA Works with Intesis AC Cloud Control¬ app Wired Module Model: FJ-AC-WIFI-1 Works with Intesis AC Cloud Control¬ app Wi-Fi Module Model: UTY-TFNXZ2 Works with FGLair¬ app (Room temp DOES NOT display in FGLair app) Wired Module Model: FJ-RC-WIFI-1NA Works with Intesis AC Cloud Control¬ app Wi-Fi Module Model: UTY-TFSXZ2 UTY-TFSXF1 Works with FGLair¬ app (Room temp DOES display in FGLair app) ADDITIONAL CONTROLS Network Converter UTY-VTGX The Network Converter is used to control and monitor one or more single-zone Halcyon indoor units (max of 16 IDU’s per converter) through Airstage VRF Central Controllers. Thermostat Converter UTY-TTRX Control Halcyon products1 using a third party thermostat. Up to 16 indoor units can be connected as a group to one thermostat convertor. Modbus Converter UTY-VMSX Control and monitor systems over Modbus RTU. 2 BACnet Module FJ-AC-BAC-1L Works with Intesis AC Cloud Control¬ app Modbus Gateway FJ-RC-MBS-1 Control and monitor systems over Modbus RTU. 1: NOT compatible with models ABU18/24RULX, ABU36RSLX, AUU18/24/36/42RCLX. 2: Compatible with ARU_RGLX, AUU_RGLX, ASU_LMAS, ASU_LZAS. SAMPLE WI-FI APP SCREEN DISPLAYS FGLAir¬ Intesis AC Cloud Control¬ INTERFACE KITS Human Sensor Kit UTY-SHZXC For large circular cassette. Interface Kit UTY-XCBXZ2 Required to connect ASU7RLF1, 9RLF1, 12RLF1 and 15RLF1 to Wired Remotes UTY-RNNUM and UTY-RVNUM, Dry Contact Wire Kit UTY-XWZX, and Simple Remote Control UTY-RSNUM. Interface Kit UTY-TWRXZ2 Required to connect ASU09, 12LMAS, and ASU09, 12, 15LZAS to Wired Remotes UTY-RNRUZ Series, UTY-RSRY, UTY-RHRY, UTY-TTRX Thermostat Converter, and Dry Contact Wire Kit UTY-XWZXZ5. FRESH AIR INTAKE KITS High Humidity Insulation Kit UTZ-KXGC Compatible with Compact Cassette. Additional insulation which may be needed when cassettes are installed in high humidity areas. Fresh Air Intake Kit UTZ-VXAA Fresh air kit for AUU7-9-12-18RLF units. Mixes room air then passes it through a heat exchanger. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or 90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Fresh Air Intake Kit KHRS940-25 Fresh air kit for RULX/RSLX systems. Kit contains Current Sensor with Built-in Relay and Switching Power Supply. Requires field supplied ductwork and a fan capable of generating 15 CFM at a static pressure of approximately 0.26” WC. Air Outlet Shutter Plate UTR-YDZK Compatible with RGLX Large Cassette. Install in a single outlet, to provide a 3-way airflow pattern. Only one supply air outlet can be blocked at a time. Air Outlet Shutter Plate UTR-YDZB Compatible with Compact Cassette. In a 3-way air flow configuration an Air Outlet Shutter Plate kit is required to block air flow of 1 louver. Fresh Air Kit UTZ-VXRA For AUU18-24-30-36-42-48RGLX units. Mixes room air then passes it through a heat exchanger. Allows for a 4-inch flex duct connection. Allows up to 10% if high airflow volume. 71 ACCESSORIES MISCELLANEOUS 3-Pole Single Throw Safety Switch K3PST For use where code requires a disconnect at the indoor unit. Not compatible with AOU45RLXFZ. R410A Swivel Adapter K9R410A55 In order to minimize incorrect charging of systems with R410A Fujitsu uses a different access port. Contractors will need this 55-degree swivel access fitting. not compatible with AOU45RLXFZ. Plug Model UTY-WIFI In order to connect certain models to Wired Wi-Fi Module, FJ-RC-WIFI-1NA, this plug must be used. Condensate Pump UTR-DPB24T 18+18 Combo Fittings Kit K9FZ1818 Auto Louver Grille Kit UTD-GX(S/T)A-W (for ARU7/9/12) UTD-GX(S/T)B-W (for ARU18) UTD-GX(S/T)C-W (for ARU24) OEM design plugs into factory harness for ease of installation. Rated for 11.8” of vertical lift. Only used with System 36RSLX. Allows two ASU18RLF1 indoor units to be used on an outdoor AOU36RLXFZ1. Requires special piping; limited to only 18,000 BTU models. Total BTU capacity is limited to 31,600 BTU in cooling. The kit upsizes linesets to 3/8” and 1/2”. Auto Louver provides comfortable airflow and blends in with various interiors. Grille can be connected either directly to indoor unit or through the rectangular duct. Only compatible with ARU models with serial numbers greater than 2000. Wide Panel UTG-AKXA-W Hides the gap between the ceiling hole and the cassette grille. Panel Spacer UTG-BKXA-W If there is not enough height in the ceiling space, by inserting this spacer between the cassette grille and the ceiling surface, the height of the body goes into the ceiling space becomes 2 in. (50mm) lower. High Humidity Insulation Kit UTZ-KXRA Compatible with RGLX Large Cassette. Install when the under-roof humidity is over 80% and the temperature is over 86˚F (30˚C) Wind Baffles Ensure continued operation during high wind conditions, especially with roof-mounted units. Wind Baffles prevent nuisance stoppage of outdoor unit, if wind gusts reverse fan rotation while the fan motor is off. Reference Wind Baffle chart below. Electric Heater Kit RXBH-1724***-A Series Compatible with AMUG24, 30, 36, 48LMAS Reference multi- position AHU documentation for compatibility. Electric Heater Jumper Bar RXBJ-A21* Required for electric heater kit 13kW and above. Indoor unit37.4 in. Panel 23.6 23.6 (in.) Panel spacer 9.5 in. HALCYON MODEL WIND BAFFLE MODEL HALCYON MODEL WIND BAFFLE MODEL NOTE: Wind baffles do not extend low ambient cooling capacities. Please refer to Application Buletin AH20201101A for best practices regarding wind baffle usage. AOU9RL2 UTZ-DUWBCA AOU18RLXFW1 UTZ-DUWBVWA AOU12RL2 AOU24RLXFW1 AOUG09LMAS1 UTZ-DUWBG2A AOU18RLXFWH AOUG12LMAS1 AOU24RLXFWH AOUG09LMAH1^AOU30RLXB AOUG12LMAH1^AOU36RLXB AOUG09LZAS1 UTZ-DUWBG3A AOU18RLX AOUG12LZAS1 AOU24RLX AOUG15LZAS1 AOU36RLX AOUG09LZAH1 AOU18RLXFZH AOUG12LZAH1 AOU24RLXFZH AOUG15LZAH1 AOU36RLXFZ1 AOU45RLXFZ UTZ-DUWBUA AOU18RGLX AOU36RLXFZH AOU24RGLX AOUG36LMAS1 AOU30RGLX AOUG48LMAS1 AOU36RGLX AOU30RLXEH UTZ-DUWBYA* AOU18RLXFZ UTZ-DUWBVWAAOU42RGLXAOU24RLXFZ AOU48RGLX * Please note that these ship with 2 wind baffle units. ^Coming Q3 2021. WIND BAFFLE COMPATIBLE UNITS 72 MISCELLANEOUS LINESET SIZES AND LENGTHS - SINGLE ZONE SINGLE-ZONE SYSTEMS WALL MOUNTED FLOOR MOUNT 9RL209LMAS109LMAH109LZAS109LZAH112RL212LMAS112LMAH112LZAS112LZAH115LZAS115LZAH118RLB18RLXFW118RLXFWH24RLB24RLXFW124RLXFWH30RLXB30RLXEH36RLXB9RLFF9RLFFH12RLFF12RLFFH15RLFF15RLFFH1/4” x 3/8”l l l l l l l l l l l l l l 1/4” x 1/2”l l l l l l 3/8” x 5/8”l l l l l l l Total System Max. Combined Pipe Length ft (m) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 165 (50) 165 (50) 66 (20) 165 (50) 165 (50) 165 (50) 246 (75) 165 (50) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) Max. Pre-charge Lineset length ft (m) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 66 (20) 66 (20) 49 (15) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) Min. Lineset Length ft (m) 10 (3) 16 (5) 16 (5) 16 (5) 16 (5) 10 (3) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 10 (3) 16 (5) 16 (5) 10 (3) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 10 (3) 10 (3) 10 (3) 10 (3) 10 (3) 10 (3) While these systems share indoor units, different line sizes are required. SINGLE-ZONE SYSTEMS COMPACT CASSETTE SLIM DUCT MEDIUM STATIC DUCTED MULTI-POSITION AIR HANDLER UNIVERSAL FLOOR / CEILING CIRCULAR FLOW LARGE CASSETTE 9RLFCC12RLFCC18RLFCC9RLFCD12RLFCD18RLFCD12RGLXD18RGLXD24RGLXD30RGLXD36RGLXD42RGLXD48RGLXD24RGLXM30RGLXM36LMAS148LMAS118RULX24RULX36RSLX18RGLXC24RGLXC30RGLXC36RGLXC42RGLXC48RGLXC1/4” x 3/8”l l l l l 1/4” x 1/2”l l l l l 3/8” x 5/8”l l l l l l l l l l l l l l l l Total System Max. Combined Pipe Length ft (m) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 66 (20) 164 (50) 164 (50) 164 (50) 164 (50) 246 (75) 246 (75) 164 (50) 164 (50) 230 (70) 230 (70) 165 (50) 165 (50) 165 (50) 164 (50) 164 (50) 164 (50) 164 (50) 164 (50) 164 (50) Max. Pre-charge Lineset length ft (m) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 49 (15) 66 (20) 66 (20) 66 (20) 66 (20) 98 (30) 98 (30) 66 (20) 66 (20) 98 (30) 98 (30) 49 (15) 49 (15) 49 (15) 66 (20) 66 (20) 66 (20) 66 (20) 98 (30) 98 (30) Min. Lineset Length ft (m) 10 (3) 10 (3) 10 (3) 10 (3) 10 (3) 10 (3) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5) 73 MISCELLANEOUS MULTI / FLEX ZONE MODELS - INDOOR UNITS WALL MOUNTED FLOOR MOUNT SLIM DUCT COMPACT CASSETTE MIXED ASU7RLF1ASU9RLF1ASU12RLF1ASU15RLF1ASU18RLFASU24RLFAGU9RLFAGU12RLFAGU15RLFARU7RLFARU9RLFARU12RLFARU18RLFARU24RLFAUU7RLFAUU9RLFAUU12RLFAUU18RLFASU18RLF x 2*ARU18RLF x 2*AUU18RLF x 2*1/4” x 3/8”l l l l l l l l l l l 1/4” x 1/2”l l l l l 1/4” x 5/8”l l 3/8” x 1/2”l l l Each Indoor Unit Minimum and maximum pipe lengths for multi-zone units are found on page 59 and page 61. MULTI / FLEX ZONE MODELS - OUTDOOR UNITS * 18+18 is the only 2 indoor unit combination allowed for AOU36RLXFZ1 and requires kit K9FZ1818. While these systems share indoor units, different line sizes are required.AOU18RLXFZAOU18RLXFZHAOU24RLXFZAOU24RLXFZHAOU36RLXFZ1AOU36RLXFZHAOU45RLXFZTotal System Max. Combined Pipe Length ft (m) 165 (50) 165 (50) 165 (50) 165 (50) 230 (70) 230 (70) 264 (80) Max. lineset length (Pre-charge) ft (m) 98 (30) 98 (30 98 (30 98 (30 164 (50) 164 (50) 164 (50) Min. Lineset Length ft (m) 49 (15) 49 (15) 49 (15) 49 (15) 66 (20) 49 (15) 49 (15) LINE SET SIZES AND LENGTHS - MULTI-ZONE 74 MISCELLANEOUS FUJITSU MODEL NOMENCLATURE “Next Generation” models Legacy models AOU 18 R L X F Z H 1 AOU = Outdoor(Single/Multi)Model Version. ASU = Wall Mount May not be combined. ABU = Ceiling/Universal Mount Outdoor: H = XLTH ARU = Ducted Z = Zone AUU = Cassette W = Wall Mount Only AGU = Floor Mount C = Cassette BTUh in thousands D = Ducted R = Reverse Cycle Heat Pump F = HFI (when followed by L = Inverter a “W” or “Z”) or Floor Mount S = Ceiling Susp.W = Wall Mount Only U = Universal C = Compact Cassette or Slim Duct G = Large Cassette / Medium Static B = 230V E = Engineering Series A = R410A X = Extended Line Set L = Inverter S = Super Efficient B = 230V A O U G 12 L Z A S 1 A = Heat pump for N. America 1-Single-zone O = Outdoor(Single/Multi)Outdoor: S = Wall Mount S = Standard M = Multi-Position Air Handler H = XLTH U = FUJITSU/60Hz/208-230V/N. America Indoor: System Generation S=Standard A-Z Series(Version) A-Z BTUh in thousands Z = High Tier M = Standard L = R410A/Inverter/Cooling and Heating(H/P) 75 WARNING Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only parts and accessories supplied or specified by Fujitsu. Ask a licensed contractor to install parts and accessories. Use of unauthorized or improper installation of parts and accessories can result in injury or property damage. Read the owner’s operation manual carefully before using this product. The owners operation manual provides important safety instructions and warnings which should be followed closely. For any questions or concerns, please contact Fujitsu General America, Inc. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. HEAT PUMP DISCLAIMER In most climates a heat pump will handle all of your heating needs. However, this system sometimes requires some other additional source of heat to satisfy heating requirements in the coldest environments. Almost all of Fujitsu’s heat pumps use inverter technology and as such offer a wider operating range and more heat capacity than a standard heat pump but will not provide adequate heating if improperly sized or operated outside of its operating range. Specifications vary by model; please consult your contractor before choosing a heat pump as your only source of heat. Systems will maintain temperature up to +/-4 degrees relative to set temperature. To increase energy efficiency on multi-type systems, you should turn off the evaporators when heating or cooling is not needed. DISCLAIMER Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. ISO ISO14001 is the standard defined by the International Organization for Standardization (ISO) related to environmental management systems. Fujitsu General America, Inc. has been acknowledged by an internationally accredited compliance organization as having an appropriate program of environmental protection procedures and activities to meet the requirements of ISO14001. The air conditioners manufactured by Fujitsu have received ISO9001 series certification for quality assurance. AHRI ENERGY GUIDE® PROGRAM (U.S.) To view AHRI numbers or Energy Guide labels, please go to www.ahridirectory.org. ASTM Our outdoor units shall withstand 1,000 hours of salt spray tested per procedure ASTM B117. RoHS COMPLIANT Fujitsu participates in the RoHS Directive, which is the Restriction of Hazardous Substances in electrical and electronic equipment. It is an EU directive intended protect the environment by forcing manufacturers to eliminate or severely curtail the use of cadmium, hexavalent chromium, and lead in all products from automobiles to consumer electronics. HRAI ENERGUIDE® PROGRAM (CANADA) Samples: COMPLETE SYSTEM WARRANTY Standard warranties vary depending on model: 2 6 Year Compressor / 2 Year Parts warranty OR 5 7 Year Compressor / 5 Year Parts warranty. Extended warranties include: 10 Year Compressor/Parts warranty for Halcyon systems that have been installed by a licensed contractor and the online Product Registration* has been submitted. 12 Year Compressor/Parts warranty for Halcyon systems that have been installed by an Elite Contractor and the online Product Registration* has been submitted. Systems must be registered within 60 days of installation for extended warranty. 10-Year and 12-Year warranties exclude: R22 models, IAQ models, ASU30RLX, ABU18RULX, ABU24RULX, ABU36RSLX, AUU18RLCX, AUU24RCLX, AUU36RCLX, AUU42RCLX, AOU18RLX, AOU24RLX, AOU30RLX, AOU36RLX, AOU42RLX * Residents of California and Quebec are not required to register the System in order to obtain all of the rights and remedies applicable to this Warranty. For full details, see Halcyon Warranty Statement. TRADEMARKS The Fujitsu logo is a registered trademark of Fujitsu Limited. is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark of Japan, the USA, and other countries or areas. is a worldwide trademark of FUJITSU GENERAL LIMITED. ENERGY STAR® is a registered trademark of the EPA and DOE. Copyright © 2021 Fujitsu General America, Inc. NON-INTERNET RETAIL POLICY Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial numbers have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY WARRANTY. NOTE •Condensing units come pre-charged from factory. Additional refrigerant may be required, be sure to check installation manual for more details. •Cooling capacity is based on the following conditions: Indoor temperature: 80°F DB/67°F WB (26.7°C DB/19.4°C WB) Outdoor temperature: 95°F DB/75°F WB (35°C DB/23.9°C WB) •Heating capacity is based on the following conditions: Indoor temperature: 70°F DB (21.1°C DB) Outdoor temperature: 47°F DB/43°F WB (8.3°C DB/6.1°C WB) • ISO9001 • ISO14001 THINGS TO KNOW BEFORE YOU INSTALL A FUJITSU SYSTEM THINGS TO KNOW BEFORE YOU BUY A FUJITSU SYSTEM CERTIFICATIONS 14.0 - 33.0 FEATURES FUJITSU GENERAL AMERICA, INC. 340 Changebridge Rd Pine Brook, NJ 07058 Toll Free: (888) 888-3424 Local: (973) 575-0380 Email: hvac@fujitsugeneral.com www.fujitsugeneral.com A subsidiary of FUJITSU GENERAL LIMITED Distributed by: Part #6-26-FG2028 Rev. 3 /2021 Halcyon Mini-Splits Are For You If: • If you want to reduce your utility bills by up to 30% • Central air quotes give you sticker shock • Want to reclaim attic and closet space occupied by ductwork • You have warm or cold spots in your home or business • Your window air conditioner’s noise prevents you from hearing the television For over 40 years, making the hottest places cool and the coolest places... more comfortable. The Fujitsu logo is a registered trademark of Fujitsu Limited. The logo and name is a trademark of Fujitsu General America, Inc. Copyright 2021 Fujitsu General America, Inc.