Loading...
CABINET_507_Wed_May_5_2021_07-25-35TITLE SHEET507/1342.520601, -70.904906SEQUENCE ID/CABINET ID:SITE INFORMATIONSEQUENCE ID:507CABINET ID:13LATITUDE:42.520601LONGITUDE:-70.904906STREET ADDRESS:150A FEDERAL ST.CITY, STATE, ZIP:SALEM, MA 01970COUNTY:ESSEX COUNTYJURISDICTION:CITY OF SALEMPROPERTY OWNER:PUBLIC RIGHT-OF-WAYAPPLICANT:ENGINEERJACOBS TELECOMMUNICATION, INC.5449 BELLS FERRY ROADACWORTH, GA 30102PROJECT MANAGERCONTACT: BRAD THOMASTEL: 770-527-0655GENERAL NOTESTHE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OREFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATEROR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE ISPROPOSED.PRIOR TO ANY CONSTRUCTION WORK, CONTRACTOR SHALL LOCATE ALLUNDERGROUND UTILITIES. ALL UTILITIES SHALL BE MARKED.THIS DESIGN IS SUBJECT TO ANY JURISDICTIONAL AND OWNER APPROVALSINCLUDING JURISDICTIONAL REQUIREMENTS, RF EQUIPMENTCONFIGURATION, AND FINAL UTILITY COORDINATION WITH PUBLIC POWERAND UTILITY PROVIDERS. CONTRACTOR TO CONFIRM FINAL REQUIREMENTSWITH OWNER.DRAWING INDEXSHEET NO:SHEET TITLECODES2014 NATIONAL ELECTRICAL CODELOCAL MUNICIPAL CODES AND ORDINANCES.DO NOT SCALE DRAWINGSCONTRACTORS SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, ANDFIELD CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THEARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFOREPROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.PROJECT DESCRIPTIONEND USER PROPOSES TO INSTALL EQUIPMENT WITHIN AN EXISTINGRIGHT-OF-WAY.THE SCOPE WILL CONSIST OF THE FOLLOWING:INSTALL A NEW FIBER CABINET AND EQUIPMENT ON A CONCRETE PADWITHIN AN EXISTING RIGHT-OF-WAY. HANDHOLE AND UNDERGROUNDCONDUIT WILL ALSO BE INSTALLED.FIBER SUPPORT CABINETTYPE OF CONSTRUCTION:HANDICAP REQUIREMENTS:UNMANNED TELECOMMUNICATIONS CABINET.FACILITY IS UNMANNED AND NOT FOR HUMANHABITATION. HANDICAPPED ACCESS NOTREQUIRED.PLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:T-1IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECAT-1TITLE SHEETELECTRICAL DETAILSE-1SITE OVERVIEWA-1DETAILED SITE PLANC-1EXCAVATION DETAILS C-2EQUIPMENT DETAILSEQ-1VICINITY MAPNFEDERAL ST., EAST ROWLOCATION DETAILS:STREET ADDRESS:150A FEDERAL ST. SALEM,MA 01970SIFI NETWORKS SALEM, LLC.55 MADISON, AVEMORRISTOWN, NJ 07960ATTN: LINDA CALNANAPPROX 135'' NORTH OF FEDERAL ST. WWSSSS S S S WSSITE OVERVIEWSITE OVERVIEW1SCALE: 1/32" = 1'-0"PLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:A-1IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECASCALE: N.T.S.SITE PHOTO2(P) SIFI CABINET EQUIPMENTCONSTRUCTION AREASEE SHEET C-1NFACE OFCURB (TYP.)RIGHT-OF-WAY (TYP.)PROPOSED ALCATEL-LUCENTALP-248 ELECTRONICSCABINET ON A 6'x4'x6"CONCRETE PAD34'-0"E.O.P.50'-0"R.O.W.(E) STREET LIGHTEDGE OFPAVEMENT (TYP.)WATER (TYP.)FLINT ST.TREE (TYP)(E) UTILITYPOLEFEDERAL ST.SEWER (TYP.)FIREHYDRANT(TYP)±135'-0" FEDERAL ST. S S S S S S S S DETAILED SITE PLANDETAILED SITE PLAN1SCALE:3/16" = 1'-0"PLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:C-1IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECANPROPOSED ALCATEL-LUCENTALP-248 ELECTRONICSCABINET ON A 6'x4'x6"CONCRETE PAD34'-0"±GRASSPROPOSED METERENCLOSURE ON POWERTRANSFER SWITCHNOTE:THIS SITE PLAN WAS GENERATED WITHOUT THE USE OFA SURVEY, PROPERTY LINES, RIGHT-OF-WAYS, POWER& TELCO UTILITY POINT CONNECTIONS/ROUTES ANDEASEMENTS SHOWN ON THESE PLANS ARE ESTIMATED.ALL ITEMS AND DIMENSIONS SHOULD BE VERIFIED INTHE FIELD.PROPOSED FIBER FEED (TYP.)FLINT ST.17'-0"0'-11"±0'-11"±RIGHT-OF-WAY (TYP.)50'-0"±R.O.W.25'-0"R.O.W.EDGE OF PAVEMENTFACE OF CURB1' -0 "±4'-0"±1'-1"±0'-9"±1'-1"±PROPOSED 3'x5'HANDHOLD(TYP. OF 2)4'-0"±PROPOSED 3'x5'HANDHOLD(TYP. OF 2) EXCAVATION DETAILSCURB CUT DROP INSTALLATION DETAIL (PLAN VIEW)3SCALE: N.T.S.SCALE: N.T.S.36" MIN (SEE EV-1 FOR DEPTHS)MATCH EXISTINGEXISTING GRADETRENCHING ANDBACKFILLING BY G.C.6" WIDE DETECTABLE WARNINGTAPE @ 6" BURIALCONDUIT AS SPECIFIEDCLEAN BACKFILL(VERIFY UTILITY COMPANY REQUIREMENTS)TRENCH SECTION DETAIL2SCALE: N.T.S.4SCALE: N.T.S.CURB CUT DROP INSTALLATION DETAIL (PROFILE)16" MIN.18" MAX.TRENCH BEHIND CURB TO PROPERTY LINE.BACKFILLED TRENCH WITH COMPACTED NATIVEBACKFILL. SEE SIDEWALK NOTE BELOW.EX. CONC CURB1.CUT A 3/4" TO 1" WIDE TRENCH IN EXISTINGCONCRETE CURB AT AN EXISTING JOINT.2.PLACE DROP CONDUITS IN TRENCH UNDER CURB.3.RESTORE TRENCH IN CURB WITH APPROVEDMATERIAL.SEE MICROTRENCH TYPICAL CROSS-SECTIONFOR REINSTATEMENT REQUIREMENTS.EX PAVEMENTTHRU CONDUITS.CONDUIT COUNT ANDSIZE VARIES.DROP CONDUITS. CONDUITCOUNT AND SIZE VARIES.DROP CONDUITS. CONDUITCOUNT AND SIZE VARIES.EDGE OF 3'x5'x3' HANDHOLEEDGE OF 3'x5'x3' HANDHOLEDROP CONDUITSDIRECTION OF NAPBACK OF CURBFACE OF CURBEDGE OF PAVEMENTTHRU CONDUITSTRACER WIRE IN MICROTRENCHRUNNING LINELIMITS OFMICROTRENCH1.CUT A 3/4" TO 1" WIDE TRENCH IN EXISTINGCONCRETE CURB AT AN EXISTING JOINT.2.PLACE DROP CONDUITS IN TRENCH UNDER CURB.3.RESTORE TRENCH IN CURB WITH APPROVEDMATERIAL.HANDHOLEPLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:C-2IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECAPULL BACK TRACER WIRE AT DROP LOCATION AND LEAVE3' MINIMUM OF TRACER WIRE COILED AT DROP CONDUITSTUB. TRACER WIRE SHOULD BE CONTINUOUS INTO ANDOUT OF DROP LOCATION AND SHOULD NOT BE CUT.SCALE: N.T.S.CABINET BOLLARDS DETAILROUND CEMENTCONCRETE FILL3" WIDE REFLECTORTAPE (YELLOW)4" GALVANIZED STEEL PIPEFILLED WITH CEMENTCONCRETE (POWDERCOATED BLACK)CEMENT CONCRETEENCASEMENTPAPER BOARD FORM8" 4'-0"2'-0"6"12" ØSEE APPLICABLETYPICAL SECTION LOGO LOGOTIER 15TIER 15EQUIPMENT DETAILS3'-2.75" 5'-2.75"3'-0"2'-10.75"4'-10.75"3'-0"5'-0"3.0"QUAZITE LOGOSKID RESISTANT SURFACEC62366003A3/4" x 4" PULL SLOTW/Ø1/4" CENTER PIN(4 PLACES)2X Ø7/8" THRU X Ø13/8" X 1/2" DEEPCOUNTERBORE1/2-13 UNCLIFTING BOLT(4 PLACES)BOTTOM OPENING26-3/4" x 50-3/4"B54366036ASLAB4'-0"6' -0 "BLOCKOUT (TYP.)THIN WALL KNOCKOUTSPECIFICATIONS:1.CONCRETE: HAS A DESIGN STRENGTH OF 5,000PSI@ 28 DAYS.2.STEEL REINFORCEMENT: ASTM A-615, GRADE 6.03.SLAB SHALL BE SUPPORTED BY 3" MIN. LAYER OFLEVEL COMPACTED CRUSHED STONE OR SANDBED.4.SLAB DESIGNED FOR 3,000 LD DEAD LOAD.AT&T ALP-248 PADWEIGHT: 1,698 LBS.ITEM #: 1500100CABINET1SCALE: N.T.S.CABINET DETAILHANDHOLE DETAIL7SCALE: N.T.S.4SCALE: N.T.S.CABINET BASE2SCALE: N.T.S.PRE-CAST PAD6SCALE: N.T.S.5SCALE: N.T.S.POWER PEDESTAL3SCALE: N.T.S.MANUFACTURER:ALCATEL-LUCENTMODEL: ALP-248HEIGHT: 48 INWIDTH: 49.9 INDEPTH: 25.8 INWEIGHT: 400 - 1070 LBSMANUFACTURER: HUBBELLMODEL: C62366003A &B54366036ALENGTH: 62.75 INWIDTH: 38.75 INDEPTH: 36.0 INPLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:EQ-1IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECAPOWER ENTRANCE-BOTTOM VIEWPOWER PEDESTAL3.1253.0"Ø KO10.2551.5"Ø KO3.50"3.50"PLANFRONTSIDE18.81"46.0"10.86"24.0"MANUFACTURER: VERTIVMODEL: PE24ME4PE24MEBBCRF3ZMEZ1HEIGHT: 46.0 INWIDTH : 18.81 INDEPTH: 10.86 IN40.0" 16.0"3.37"9.62" ELECTRICAL DETAILSELECTRICAL ONE-LINE DIAGRAM W/GROUND4SCALE: N.T.S.GROUND RING DETAIL2SCALE: N.T.S.PANEL SCHEDULE1SCALE: N.T.S.EXISTING GRADE3'x5'x3' HANDHOLE (TYP.)PROPOSED UNDERGROUNDPOWER IN CONDUIT#2 SOLID TINNEDCOPPER WIRE5/8" x10' COPPER CLADGROUND ROD (TYP. OF 4)CADWELD (TYP.)CONNECTION DETAILS3SCALE: N.T.S.MECHANICALCONNECTION (TYP.)TO POINT OF CONNECTIONMECHANICAL CONNECTIONCADWELD CONNECTIONLEGENDCOMPRESSION CONNECTIONTYPE VVTYPE GTTYPE TATYPE GYTYPE GRTYPE VNTYPE NCTYPE VSTYPE VBTYPE SSTYPE PTNOTE:ERICO EXOTHERMIC "MOLD TYPES" SHOWNHERE ARE EXAMPLES. CONSULT WITHPROJECT MANAGER FOR SPECIFIC MOLDSTO BE USED FOR THIS PROJECT.TYPE 2-YA-2TYPE XATYPE YA-2TYPE HS THIN WALL C-TAP WITHBLACK DYE INDEX#6 AWG SOLID TIN COATED MAINGROUND CONDUCTOR#6 AWG STRANDED BLACK JACKETED ORTIN COATED BARE WIRENOTE:CONTRACTOR TO SURROUNDCOMPLETED CONNECTION WITHHEAT-SHRINK TUBING TO ENSUREWEATHER PROOF CONNECTION.WELD CONNECTION DETAILSC-TAP DETAILSNOTES:1.PANEL IS INTEGRAL TO EQUIPMENT CABINET. INFORMATION SHOWN PROVIDED BY MANUFACTURER.2.CONTRACTOR TO PROVIDE LABEL LISTING MAXIMUM AVAILABLE FAULT CURRENT PER NEC 110.24 REQUIREMENTS.CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY PROVIDER.NO.1234LOAD SERVEDMAIN CIRCUIT BREAKERØBVAAMP/POLECKT #5678PANEL SCHEDULEVOLT AMPSØAVA--3600-3600---36003600100/236007200TOTAL VOLT AMPERESDEMAND VAPANEL WITH SEPARATEGROUND BUS120/240 VOLTS1 PHASE3 WIREINTERNAL100A, 2 POLEMAIN BREAKERLOAD SERVED-ØBVAAMP/POLE--VOLT AMPSØAVA-------------CABINET BREAKER30/2GROUND RING AROUNDCABINET 30" MIN. DEPTH(SEE 3/EQ-1)1.GROUND RING IS COMPOSED OF 2 AWG SOLID TINNED COPPER WIRE.2.ALL GROUND RODS ARE A MINIMUM OF 8' IN LENGTH.3.ALL TERMINATIONS ONTO THE GROUND RING ARE POWER (EXOTHERMIC)WELDS4.THE GROUND RING SHOULD NOT EXTEND OUTSIDE PAD PERIMETER BY MORETHAN 2'.5.GROUND RING HAS A MINIMUM OF 2 GROUND RODS, AT OPPOSING ENDS. IFGROUND RESISTANCE IS GREATER THAN 25 OHMS, THEN APPLY ADDITIONALGROUND RODS.6.ALL EARTH GROUND WIRES, INCLUDING GROUND RING, IS 2 AWG SOLIDTINNED COPPER, MAINTAINING A 8" OR GREATER BEND RADIUS.7.ALL GROUND TERMINATIONS INTO THE ALP-248 MUST BE A LISTED TWO-HOLECOMPRESSION LUG, SELECTED FOR THE WIRE USED AND CRIMPED INACCORDANCE TOT HE MANUFACTURER'S INSTRUCTIONS.8.IF A JWI/SAIC (CROSS CONNECT) IS LOCATED WITHIN 10', APPLY A 2 AWGTINNED WIREBOND BETWEEN THE JWI/SAIC AND THE ALP PRIMARY GROUND.PLANS PREPARED BY:507 / 135449 BELLS FERRY ROADACWORTH, GEORGIA 30102770-701-2500, FAX: 770-701-2501Jacobs Telecommunication. Inc.ENGINEERING LICENSE:RDESCRIPTIONDATEBYREVSEQUENCE ID / CABINET ID:SITE ADDRESS:SHEET DESCRIPTION:SHEET NUMBER:REVISIONS:E-1IT IS A VIOLATION OF THE LAW FOR ANYPERSON, UNLESS THEY ARE ACTINGUNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTERTHIS DOCUMENTFOR REVIEW01/05/2021TECAPROPOSED ALCATEL-LUCENT ALP-248ELECTRONICS CABINETPROPOSED METERENCLOSURE ON POWERTRANSFER SWITCH100A MCB PANEL (PROVIDED WITH CABINET)SEPERATE GROUNDRODSEE 2/E-13'x5'x3' HANDHOLE (TYP.)