33 Flint Street Permit set Rev'd 11-20-20REMOVE EXISTING SPIRAL STAIR INFILL EXST'G OPENING W/ P.T. 2 X 8 @ 16" O.C. START DATE: 10/22/20 DRAWN BY: TS SCALE: AS NOTED PROJECT #: 2020-35PROPOSED RENOVATIONS33 FLINT STREETSALEM, MA.DECK / PARTIAL SECOND FLOOR PLAN 1/4" = 1'-0"TIMOTHY SHEEHAN ARCHITECT9 WALL STREETCHARLESTOWN, MA. 02129PERMIT SET REV'D 11-20-22 DECK PLANSA1 1. ALL WORK SHALL CONFORM TO THE IBC 2015, IRC 2015, MASSACHUSETTS AMENDMENTS TO IBC /IRC , THE CITY OF SALEM BYLAWS AND ALL APPLICABLE OSHA STANDARDS. 2. UTILITIES MAY BE IN THE VICINITY OF THE EXCAVATIONS. PRIOR TO EXCAVATING THE EXCAVATION CONTRACTOR SHALL COMPLY WITH THE LOCAL "DIG-SAFE" REQUIREMENTS AND OBTAIN ALL EXISTING UTILITY INFORMATION FROM THE OWNER. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCY TO THE ARCHITECT BEFORE ORDERING MATERIAL AND PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SHORING TO SUPPORT EXISTING SURROUNDING STRUCTURES AND AGAINST WIND FORCES AND ALL CONSTRUCTION LOADS THROUGHOUT THE WORK. 5. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE DRAWINGS OF OTHER DISCIPLINES FOR THE LOCATION AND DIMENSIONS OF ALL RELATED ITEMS. GENERAL REQUIREMENTS 6. THE CONTRACTOR SHALL COORDINATE ALL FRAMING DIMENSIONS WITH THE APPROVED DRAWINGS OF ALL PURCHASED WINDOW AND DOOR DIMENSIONS. - FOUNDATION WALLS, FOOTINGS & INTERIOR BASEMENT SLABS: 1. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH; IT SHALL BE NORMAL WEIGHT CONCRETE; THE DESIGN MIX AND QUALITY CONTROL SHALL MEET ALL STANDARDS OF THE AMERICAN CONCRETE INSTITUTE FOR REINFORCED AND UNREINFORCED CONCRETE, 2. ALL REINFORCING STEEL SHALL BE ASTM A-615. 3,500 PSI, AIR-ENTRAINED - 5-7% BY VOLUME. AS FOLLOWS: CONCRETE: 1. ALL FRAMING LUMBER SHALL COMPLY WITH THE NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADED LUMBER AND ITS FASTENINGS, LATEST EDITION; AND AS INDICATED IN THE CONTRACT DOCUMENTS. 2. ALL FRAMING LUMBER SHALL BE PROTECTED FROM EXPOSURE TO THE WEATHER. LUMBER: A. FRAMING LUMBER: 3. FRAMING LUMBER SHALL BE USED WITH A MAXIMUM 19% MOISTURE CONTENT AND WITH MINIMUM DESIGN VALUES AS INDICATED: STUDS: FB = 700 PSI. ALL COMPONENTS: E = 1400000 PSI. 4. "PT" WHERE INDICATED ON THE DRAWINGS STANDS FOR PRESSURE PER THE IBC / IRC 2015 8. THE NAILING SCHEDULE FOR ALL DIMENSIONAL LUMBER SHALL BE 11. ALL HEADERS SHALL HAVE (2) JACKS AND (1) KING STUD EACH BRIDGING SHALL BE 1X3 MIN. 12. ALL POSTS SHALL BE (3) 2X4'S UNLESS INDICATED OTHERWISE. 16. DIAGONAL BRIDGING SHALL BE INSTALLED IN ALL FLOORS AND CEILINGS AT 8 FT. O.C., WITH ONE ROW OR BRIDGING MINIMUM AT ALL SPANS GREATER THAN 8 FT. LOCATED IN THE CENTER OF THE SPAN. WALLS 18", CONNECT LAPS WITH 8-16D NAILS. 9. LAP ALL JOISTS NOT FLUSH FRAMED AT BEAMS AND/OR BEARING 10. HEADERS OVER OPENINGS SHALL BE AS SCHEDULED BELOW, UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE DRAWINGS. -OPENINGS SIZE -AT BEAR'G WALLS -AT NON-BEAR'G WALLS LESS THAN 5 FT. (2) 2X8'S W/2 1/2" CDX PLY LAYERS (2) 2X6'S BETW. 5 & 9 FT. (2) 2X12'SW/2 1/2" CDX PLY LAYERS (2) 2X8'S 13. FURRING WALL STUDS SHALL BE CAPPED WITH A DOUBLE TOP PLATE INSTALLED TO PROVIDE OVERLAPPING AT CORNER AND INTERSECTIONS WITH BEARING PARTITIONS. END JOINTS IN TOP PLATES SHALL BE OFFSET AT LEAST 48". 14. ALL JOISTS SHALL BE STACKED AND ALIGNED DIRECTLY OVER WALL STUDS BELOW. MINIMUM OF A DOUBLED-UP FLOOR JOIST. FRAMING FOR MORE THAN 1/2 THE THE SPAN OF THE JOIST, SHALL HAVE A 15. ALL NON-BEARING PARTITION WALLS RUNNING PARALLEL WITH THE FLOOR OTHER IS FULLY DIMENSIONED AND LAID OUT. 5. TIMBER CONNECTORS SHALL BE BY "SIMPSON" OR EQUAL, AS FOLLOWS: THE CONTRACTOR SHALL NOTE THAT NOT EVERY SINGLE CONNECTION CONDITION AND DETAIL WILL BE SHOWN ON THE DRAWINGS; THE FOLLOWING SCHEDULE IS ISSUED AS A GUIDE TO COVER MOST OF THE CONDITIONS ENCOUNTERED. SOME FIELD MODIFICATIONS MAY BE REQUIRED WHEN THE GEOMETRY OF VARIOUS MEMBERS FRAMING INTO EACH - ALL JOIST HANGERS SHALL BE "FULL-DEPTH" OF THE MEMBER - ALL WOOD POST CAPS SHALL BE "SIMPSON" TYPE `CC" OR 6. ALL DOUBLE JOISTS SHALL BE NAILED TOGETHER WITH TWO ROWS OF 20D SPIKES @ 16" O.C. TRIPLE JOISTS SHALL BE BOLTED TOGETHER WITH 1/2"Ø THRU-BOLTS @18" O.C., STAGGERED (@9" O.C.). SIMILAR. BEING CONNECTED. FLOOR JOISTS. 7. PLYWOOD SHALL CONFORM TO THE AMERICAN PLYWOOD ASSOCIATION PLYWOOD DESIGN SPECIFICATION. THICKNESS SHALL BE AS INDICATED. ALL PLYWOOD USED AS SUB-FLOORING SHALL BE GLUED AND NAILED TO THE LUMBER CTD: DECK / PARTIAL FIRST FLOOR PLAN 1/4" = 1'-0" ELEC SERVICE DN DN REMOVE EXISTING SPIRAL STAIR EXISTING DECK (TO REMAIN)4'-5 1/2"7'-11" 4/6 28'-0"14'-0"REPLACE EXST'G WOOD DECKING W/ SYNTHETIC DECKING W/ S.S. HIDDEN FASTENERS SEAT SEATSEATREPLACE EXST'G WOOD DECKING W/ SYNTHETIC DECKING W/ S.S. HIDDEN FASTENERS LEFT SIDE ELEVATION 1/4" = 1'-0"10'-9 1/2"1'-6"1'-6" (2) P.T. 4 X 6 POSTS ON SIMPSON ABU GALV POST BASE 8" CONC. SONOTUBE ON 18" 'BIGFOOT' CONC. FTG. MIN. 48" BELOW GRADE ON FULLY COMPACTED SOIL 3'-0"STAIR NOTES: 16 RISERS @ 8" EA. 9 1/2" TREADS W/ 3/4" NOSINGS RAIL @ 36" ABOVE NOSINGS (3) P.T. 2 X 12 STRINGERS CEDAR RAILINGS SYNTHETIC DECKING (LANDINGS / TREADS) 36" WIDE MIN. 1 X TRIM REMOVE EXISTING SPIRAL STAIR INFILL EXST'G OPENING W/ P.T. 2 X 8 @ 16" O.C. 4"MAX.REPLACE EXST'G RAILING W/ 36" HIGH RAILING 4'-8 1/2"8'-5"9 1/2"5'-11 1/2"8'-4"3'-0"3'-0"3'-0"9 1/2"2'-5"EXST'G DECK BELOW 1 234567891011121314 1516 LANDING LANDING P.T. 2 X 8 LEDGER W/ (2) 1/2" CARRIAGE BOLTS @ 16" O.C.(2) P.T. 2 X 8(2) P.T. 2 X 8(2) P.T. 2 X 8 4'-0"1'-6"CONC. PAD CONCRETE PAD2 X 8 @ 16" O.C.2 X 8 2 X 81'-5 1/2"RAILING 8'-8"4/6 UP16R5'-11 1/2"4'-5 1/2"CONC. PAD NEW 36" RAILING 3'-0"4"MAX CLEAR