WRIGHTSOFT COMPLIANCE RPTS (42 PAGES)
Manual S Compliance Report Job: wrightsoft Date: Dec 18,2020 unit#1 By: Project Information For: 11 Rice St,Salem, Ma Cooling Equipment Design Conditions Outdoor design DB: 85.8°F Sensible gain: 12441 Btuh Entering coil DB: 75.8°F Outdoor design WB: 72.4°F Latent gain: 2622 Btuh Entering coil WB: 63.5°F Indoor design DB: 75.0°F Total gain: 15063 Btuh Indoor RH: 50% Estimated airflow: 597 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: American Standard Model: 4A7A3018H1+C(A,C,D,E)24A2G++TDR Actual airflow: 597 cfm Sensible capacity: 12530 Btuh 101%of load Latent capacity: 5370 Btuh 205%of load Total capacity: 17900 Btuh 119%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 9.4°F Heat loss: 25085 Btuh Entering coil DB: 65.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: American Standard Model: S9X2B060D3PSA"" Actual airflow: 597 cfm Output capacity: 54000 Btuh 215%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. wrightsoft' 2020-Dec-21 10:01:36 /RiCi7� Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Manual S Compliance Report Job: wrightsoft p p Date: Dec 18,2020 unit#2 By: Project Information For: 11 Rice St,Salem, Ma Cooling Equipment Design Conditions Outdoor design DB: 85.8°F Sensible gain: 29002 Btuh Entering coil DB: 77.2°F Outdoor design WB: 72.4°F Latent gain: 3403 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 32405 Btuh Indoor RH: 50% Estimated airflow: 1350 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: American Standard Model: 4A7A3043A1+H,TE48(1,2)60++TXV+TD Actual airflow: 1350 cfm Sensible capacity: 28350 Btuh 98%of load Latent capacity: 12150 Btuh 357%of load Total capacity: 40500 Btuh 125%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 9.4°F Heat loss: 48444 Btuh Entering coil DB: 67.1°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: American Standard Model: S9X2B060D3PSA** Actual airflow: 1350 cfm Output capacity: 54000 Btuh 111%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. wtrlyht>froft' 2020-Dec-21 10:01:36 Right-Suite®U niversal 2019 19.0.20 RSU 15588 Aa•tk ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Page 2 Ai- 9 Load Short Form Job: wri right Date: Dec 18,2020 Entire House By: Project Information For: 11 Rice St,Salem, Ma Design Information Htg Clg Infiltration Outside db(°F) 9 86 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 61 11 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 26 34 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) unit#1 d 1286 20620 11979 597 597 unit#2 d 1440 44045 28581 1350 1350 Entire House d 2726 64665 40560 1947 1947 Other equip loads 4954 883 Equip.@ 1.00 RSM 41443 Latent cooling 4319 TOTALS 1 2726 I 69618 I 45762 I 1947 I 1947 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �nrl1-i�Mtsof`t 2020-Dec-21 10:01:36 „ .,. , . Right-Suite®U niversal 2019 19.0.20 RSU 15588 Page 1 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE 4wrightsoft Load Short Form Job: Date: Dec 18,2020 unit#1 By: Project Information For: 11 Rice St,Salem, Ma Design Information Htg Clg Infiltration Outside db(°F) 9 86 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 61 11 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr./lb) 26 34 HEATING EQUIPMENT COOLING EQUIPMENT Make American Standard Make American Standard Trade AMERICAN STANDARD Trade AMERICAN STANDARD Model S9X2B060D3PSA** Cond 4A7A3018H1 AHRI ref 10011968 Coil C(A,C,D,E)24A2G++TDR AHRI ref 10208706 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 60000 Btuh Sensible cooling 12530 Btuh Heating output 54000 Btuh Latent cooling 5370 Btuh Temperature rise 83 °F Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 0.83 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) 1 bed#1 210 3758 2362 109 118 1 bed#1 closet 2 25 0 0 0 0 1 laundry 20 0 0 0 0 1 bathroom 70 0 0 0 0 1 kitchen 246 4578 3159 133 157 1 living area 275 2932 1804 85 90 1 bed 1 closet 8 0 0 0 0 1 bed#2 290 9351 4654 271 232 1 bed#2 closet 2 22 0 0 0 0 1 bed#2 bath 98 0 0 0 0 1 stairway 22 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �'� Wllghtsol`t' 2020-Dec-2110:01:36 — .. .. -_ ,... Right-Suite®U niversal 2019 19.0.20 RSU15588 Page ACANIK ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE unit#1 d 1286 20620 11979 597 597 Other equip loads 4465 462 Equip. @ 1.00 RSM 12441 Latent cooling 2622 TOTALS I 1286 I 25085 I 15063 I 597 I 597 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W rightsoft' 2020-Dec-21 10:01:36 /,1.(.d\ ._,.• . .—.-.. Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 ..HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Load Short Form wrightsoftJob: Date: Dec 18,2020 unit#2 By: Project Information For: 11 Rice St,Salem, Ma Design Information Htg CIg Infiltration Outside db(°F) 9 86 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 61 11 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 26 34 HEATING EQUIPMENT COOLING EQUIPMENT Make American Standard Make American Standard Trade AMERICAN STANDARD Trade AMERICAN STANDARD Model S9X2B060D3PSA** Cond 4A7A3043A1 AHRI ref 10011968 Coil H,TE48(1,2)60++TXV+TD AHRI ref 10200954 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 60000 Btuh Sensible cooling 28350 Btuh Heating output 54000 Btuh Latent cooling 12150 Btuh Temperature rise 37 °F Total cooling 40500 Btuh Actual air flow 1350 cfm Actual air flow 1350 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 0.89 ROOM NAME Area Htg load CIg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 2 bed#2 closet 10 0 0 0 0 2 half bath 28 0 0 0 0 2 closet 9 0 0 0 0 2 liv/din/kitchen 407 12842 8592 394 406 2 bed#1 192 6507 4602 199 217 2 bed#1 bath 68 2777 1213 85 57 2 bed#1 closet 60 1319 662 40 31 2 laundry 12 0 0 0 0 2 hallway 104 2855 2493 87 118 2 closet 2 16 0 0 0 0 2 bed2 bath 119 3267 1988 100 94 2 bed#2 345 10806 7223 331 341 2 nd flr entry 72 3672 1809 113 85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - tNlrightsoft' 2020-Dec-21 10:01:36 AM -, _... Right-Suite@ Universal 2019 19.0.20 RSU15588 Page 4 ..HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE unit#2 d 1440 44045 28581 1350 1350 Other equip loads 4399 421 Equip.@ 1.00 RSM 29002 Latent cooling 3403 TOTALS 1 1440 I 48444 I 32405 I 1350 I 1350 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2020-Dec-21 10:01:36 •. ., _... _.. Right-Suite®Universal 2019 19.0.20 RSU15588 Page 5 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Job: - wrightsoft Load Multizone Summary Report Date: Dec 18,2020 By: Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft3 cfm Btuh/ftz ft3 cfm Btuh/ftM unit#2 11590 0.31 60 2.1 11590 0.17 32 0.2 unit#1 10790 0.25 45 2.1 10790 0.13 24 0.2 Entire House 22380 0.28 104 2.1 22380 0.15 56 0.2 Load and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2 Btuh Btuh cfm cfm 2 bed#2 closet 10 0 0 0 0 2 half bath 28 0 0 0 0 2 closet 9 0 0 0 0 2 liv/din/kitchen 407 12842 8592 394 406 2 bed#1 192 6507 4602 199 217 2 bed#1 bath 68 2777 1213 85 57 2 bed#1 closet 60 1319 662 40 31 2 laundry 12 0 0 0 0 2 hallway 104 2855 2493 87 118 2 closet 2 16 0 0 0 0 2 bed2 bath 119 3267 1988 100 94 2 bed#2 345 10806 7223 331 341 2 nd flr entry 72 3672 1809 113 85 unit#2 1440 44045 28581 1350 1350 1 bed#1 210 3758 2362 109 118 1 bed#1 closet 2 25 0 0 0 0 1 laundry 20 0 0 0 0 1 bathroom 70 0 0 0 0 1 kitchen 246 4578 3159 133 157 1 living area 275 2932 1804 85 90 1 bed 1 closet 8 0 0 0 0 1 bed#2 290 9351 4654 271 232 1 bed#2 closet 2 22 0 0 0 0 1 bed#2 bath 98 0 0 0 0 1 stairway 22 0 0 0 0 unit#1 1286 20620 11979 597 597 Entire House 2726 64665 40560 1947 1947 Wright30}t- 2020-Dec-2110:01:36 Right-Suite®U niversa1201919.0.20 RSU15588 Page 1►�� ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE BuildingAnalysis Job: wrightsoft y Date: Dec 18,2020 Entire House By: Pro'ect Information For: 11 Rice St,Salem, Ma Desi• n Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 25.6 33.8 Dry bul b(°F) 9 86 Infiltration: Dailyrange(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 11.9 31816 45.7 VirtilaSm Glazing 28.6 12127 17.4 ads Doors 17.6 2214 3.2 Ceilings 1.9 1855 2.7 Floors 7.3 172 0.2 Wi Infiltration 2.1 6935 10.0 kfilhlim Ducts 9545 13.7 Piping 0 0 Humidification 0 0 i rys Ventilation 4954 7.1 Adjustments 0 wry Total 69618 100.0 Coolin• Component Btu h/ft2 Btuh %of load . Walls 4.5 12144 29.3 \Htilli�Ctrs Glazing 26.7 11306 27.3 Doors 6.8 859 2.1 Ceilings 2.1 2051 4.9 Floors 1.3 31 0.1 acts Infiltration 0.2 662 1.6 Ducts 9127 22.0 Ventilation 883 2.1 Internal gains 4380 10.6 Blower 0 0 Ohs' Adjustments 0 Gaa Ce ilings lings Total 41443 100.0 Latent Cooling Load =4319 Btuh Overall U-value=0.190 Btuh/ftz--°F Data entries checked. W ri�htsoft- 2020-Dec-21 10:01:36 •- Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 .„HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Buildin Anal sis Job: 4 wrightsoft g y Date: Dec 18,so2o unit#1 By: Pro'ect Information For: 11 Rice St,Salem, Ma Desi•n Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 25.6 33.8 Dry bulb(°F) 9 86 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 8.1 9062 36.1 I-Irridficzticn Glazing 28.5 5070 20.2 / VErtilaicn Doors 17.6 1476 5.9 Ceilings 0 0 0 VAN Floors 7.3 172 0.7 arts Infiltration 2.1 2961 11.8 Ducts 1878 7.5 Piping 0 0 4111 Irfiltraim Humidification 1872 7.5 Ventilation 2593 10.3 Oho- Adjustments 0 Dcas Total 25085 100.0 Claire Coolin• Component Btu h/ft2 Btuh %of load . Walls 3.0 3321 26.7 ,\Artildicn Glazing 27.0 4813 38.7 Vti herd°Furs Doors 6.8 572 4.6 Ceilings 0 0 0 Floors 1.3 31 0.2 Infiltration 0.2 283 2.3 acts Ducts 769 6.2 Ventilation 462 3.7 glirtrdicn Internal gains 2190 17.6 Dam Blower 0 0 Adjustments 0 Total 12441 100.0 Ga ir>g Latent Cooling Load =2622 Btuh Overall U-value=0.190 Btuh/ft2-°F Data entries checked. i4- wrightsoft- 2020-Dec-21 10:01:36 •-•-• -•• •- __.. Right-Suite®Universal 2019 19.0.20 RSU 15588 Page 2 /R.0 A 9 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE BuildingAnalysis Job: wrightsoft y Date: Dec 18,2020 unit#2 By: Pro'ect Information For: 11 Rice St,Salem, Ma Desi• n Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 25.6 33.8 Dry bulb(°F) 9 86 Infiltration: Dailyrange(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 14.5 22754 47.0 I111atlm Glazing 28.7 7057 14.6 v\mis_i Doors 17.6 738 1.5 f] s Ceilings 1.9 1855 3.8 Floors 0 0 0 Infiltration 2.1 3974 8.2 Ducts 7667 15.8 Piping 0 0 Irfiltraticn Humidification 2038 4.2 Ventilation 2360 4.9 Qhal Adjustments 0 �� Total 48444 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 5.6 8824 30.4 herd Cans Glazing 26.4 6493 22.4 Doors 6.8 286 1.0 Ceilings 2.1 2051 7.1 Floors 0 0 0 fps Infiltration 0.2 379 1.3 Ducts 8358 28.8 Ventilation 421 1.5 Internal gains 2190 7.6 Blower 0 0 Adjustments 0 Ga'irlg Qh� tp lir Total 29002 100.0 Latent Cooling Load =3403 Btuh Overall U-value=0.190 Btuh/ft2-°F Data entries checked. wriyhtoft' 2020-Dec-21 10:01:36 Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 /Wk ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Project SummaryJob: 441- wrightsoft Date: Dec 18,2020 Entire House By: Project Information For: 11 Rice St,Salem, Ma Notes: Desi• n Information Weather: Beverly Muni, MA, US Winter Design Conditions Summer Design Conditions Outside db 9 °F Outside db 86 °F Inside db 70 °F Inside db 75 °F Design TD 61 °F Design TD 11 °F Daily range M Relative humidity 50 % Moisture difference 34 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 55120 Btuh Structure 31433 Btuh Ducts 9545 Btuh Ducts 9127 Btuh Central vent(75 cfm) 4954 Btuh Central vent(75 cfm) 883 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 69618 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 41443 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2480 Btuh Ducts 1838 Btuh Central vent(75 cfm) 1707 Btuh Heating Cooling Area(ft2) 2726 2726 Equipment latent load 4319 Btuh Volume(1t3) 22380 22380 Air changes/hour 0.28 0.15 Equipment Total Load(Sen+Lat) 45762 Btuh Equiv.AVF(cfm) 104 56 Req.total capacity at 0.70 SHR 4.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrlghtsoft 2020•Dec-2110:01:e8 - Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE * Job:9 Pro ect Summa wrightsoft unit#1 Date: Dec 18,2020 By: Pro"ect Information For: 11 Rice St,Salem, Ma Notes: Desi• n Information Weather: Beverly Muni, MA, US Winter Design Conditions Summer Design Conditions Outside db 9 °F Outside db 86 °F Inside db 70 °F Inside db 75 °F Design TD 61 °F Design TD 11 °F Daily range M Relative humidity 50 % Moisture difference 34 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18741 Btuh Structure 11210 Btuh Ducts 1878 Btuh Ducts 769 Btuh Central vent(39 cfm) 2593 Btuh Central vent(39 cfm) 462 Btuh Outside air Outside air Humidification 1872 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25085 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12441 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1147 Btuh Ducts 582 Btuh Central vent(39 cfm) 894 Btuh ft Heating Cooling Outside air Area(ft2) 1286 1286 Equipment latent load 2622 Btuh Volume(ft3) 10790 10790 Air changes/hour 0.25 0.13 Equipment Total Load(Sen+Lat) 15063 Btuh Equiv.AVF(cfm) 45 24 Req.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make American Standard Make American Standard Trade AMERICAN STANDARD Trade AMERICAN STANDARD Model S9X2B060D3PSA** Cond 4A7A3018H1 AHRI ref 10011968 Coil C(A,C,D,E)24A2G++TDR AHRI ref 10208706 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 60000 Btuh Sensible cooling 12530 Btuh Heating output 54000 Btuh Latent cooling 5370 Btuh Temperature rise 83 °F Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrrlphftsot t• 2020-Dec-21 10:01:36 Right-Suite®Universal 2019 19.0.20 RSU15588 Page 2 .HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE -lid- Summary Date: Dec 18,2020 wrightsoft eunit#2 By: Project Information For: 11 Rice St,Salem, Ma Notes: Desi• n Information Weather: Beverly Muni, MA, US Winter Design Conditions Summer Design Conditions Outside db 9 °F Outside db 86 °F Inside db 70 °F Inside db 75 °F Design TD 61 °F Design TD 11 °F Daily range M Relative humidity 50 Moisture difference 34 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 36378 Btuh Structure 20223 Btuh Ducts 7667 Btuh Ducts 8358 Btuh Central vent(36 cfm) 2360 Btuh Central vent(36 cfm) 421 Btuh Outside air Outside air Humidification 2038 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 48444 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29002 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1334 Btuh Ducts 1256 Btuh Central vent(36 cfm) 813 Btuh Heating Cooling Outside air Area(ft2) 1440 1440 Equipment latent load 3403 Btuh Volume(f 3) 11590 11590 Air changes/hour 0.31 0.17 Equipment Total Load(Sen+Lat) 32405 Btuh Equiv.AVF(cfm) 60 32 Req.total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make American Standard Make American Standard Trade AMERICAN STANDARD Trade AMERICAN STANDARD Model S9X2B060D3PSA** Cond 4A7A3043A1 AHRI ref 10011968 Coil H,TE48(1,2)60++TXV+TD AHRI ref 10200954 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 60000 Btuh Sensible cooling 28350 Btuh Heating output 54000 Btuh Latent cooling 12150 Btuh Temperature rise 37 °F Total cooling 40500 Btuh Actual air flow 1350 cfm Actual air flow 1350 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft• 2020-Dec-21 10:01:36 ---• -•• -- -- .. Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE 9 - 9 AED Assessment Job: wrightsoft Date: Dec 18,2020 Entire House By: Project Information For: 11 Rice St, Salem, Ma Design Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 25.6 33.8 Dry bul b(°F) 9 86 Infiltration: Daily range(°F) - 18 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hmtly GaAm Load 16,c00— 14,000-- 12aoo— --.......'" ---N 10,000—/ acoo- 60:0- 4,C00— 2000— 0 I I I I I I I I I --- - f I 8 9 10 11 12 13 14 15 16 17 18 19 2D liar d ay /Hourly / lort Maximum hourly glazing load exceeds average by 11.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 41- wl-ightaol't. 2020-Dec-21 10:01:36 tK� ,. . Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 /N� ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE AED Assessment Job: -+ wrightsoft Date: Dec 18,2020 unit#1 By: Project Information For: 11 Rice St, Salem, Ma Design Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 25.6 33.8 Dry bul b(°F) 9 86 Infiltration: Daily range(°F) - 18 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity I-bjly Gazing Lsxr1 a.„ - -- AIII 0 + } 8 9 10 11 12 13 14 15 16 17 18 19 20 Fdr d Da/ /Hourly /Av.rp. A3' . Maximum hourly glazing load exceeds average by 18.5%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wrightsoft 2020-Dec-2110:0136 Atri,7� .. • Right-Suite®Universal 2019 19.0.20 RSU15588 Page 2 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Ai- AED Assessment Job: wrightsoft Date: Dec 18,2020 unit#2 By: Project Information For: 11 Rice St, Salem, Ma Design Conditions Location: Indoor: Heating Cooling Beverly Muni, MA, US Indoor temperature(°F) 70 75 Elevation: 108 ft Design TD(°F) 61 11 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 25.6 33.8 Dry bulb(°F) 9 86 Infiltration: Daily range(°F) - 18 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity y Chang Loan 9,000-- 8,0o0-- 7,000-- 6,,000-- 500D-- 4,000— a000- 1,000- 0 I I 8 9 10 11 12 13 14 15 16 17 18 19 Hu d IIN /Hourly -Average /P57int Maximum hourly glazing load exceeds average by 15.4%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 411- wrghtsoft' 2020-Dec-21 10:01:36 rt`_- T ..•. - Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 ACAOIN ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE 4 wrightsoft Right-J® Worksheet Job: Entire House Date: Dec 18,2020 By: 1 Room name Entire House unit#1 2 Exposed wall 384.5 ft 155.0 ft 3 Room height 8.2 ft d 8.4 ft d 4 Room dimensions 5 Room area 2726.3 f t' 1286.0 f t' r I I I I I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) or perimeter (ft) (Btuh) 1 Heat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12A-Osw 0.240 ne 14.54 5.64 337 280 4065 1576 148 115 1673 649 1-C 4A5-2ov 0.470 ne 28.48 24.01 36 0 1025 864 12 0 342 288 11P0 0.290 ne 17.57 6.82 21 21 369 143 21 21 369 143 12B-0sw 0.097 ne 5.88 2.05 164 97 570 199 164 97 570 199 11 4A5-20v 0.470 ne 28.48 24.01 46 0 1310 1105 46 0 1310 1105 D 11P0 0.290 ne 17.57 6.82 21 21 369 143 21 21 369 143 Vy 12A-0sw 0.240 se 14.54 5.64 768 636 9250 3587 188 158 2298 891 �G 4A5-2ov 0.470 se 28.48 30.00 132 0 3760 3960 30 0 854 900 12B-0sw 0.097 se 5.88 2.05 328 259 1522 530 328 259 1522 530 4A5-2ov 0.470 se 28.48 30.00 48 0 1367 1440 48 0 1367 1440 11P0 0.290 se 17.57 6.82 21 21 369 143 21 21 369 143 b12A-Osw 0.240 sw 14.54 5.64 328 253 3680 1427 0 0 0 0 10D-v 0.490 sw 29.69 21.72 42 0 1247 912 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 12 0 342 360 0 0 0 0 11P0 0.290 sw 17.57 6.82 21 21 369 143 0 0 0 0 H12B-0sw 0.097 sw 5.88 2.05 164 131 770 268 164 131 770 268 4A5-2ov 0.470 sw 28.48 30.00 12 0 342 360 12 0 342 360 I 1J 11 PO 0.290 sw 17.57 6.82 21 21 369 143 21 21 369 143 12A-Osw 0.240 nw 14.54 5.64 776 683 9934 3852 20 14 204 79 4A5-20v 0.470 nw 28.48 24.01 72 0 2051 1729 6 0 171 144 D 11P0 0.290 nw 17.57 6.82 21 21 369 143 0 0 0 0 1/ 12B-0sw 0.097 nw 5.88 2.05 369 345 2025 705 369 345 2025 705 G 4A5-20v 0.470 nw 28.48 24.01 24 0 684 576 24 0 684 576 C 16A-30ad 0.032 - 1.94 2.14 957 957 1855 2051 0 0 0 0 F 19A-Obsto 0.368 - 7.26 1.29 24 24 172 31 24 24 172 31 6 c)AED excursionin 481851 263910 1 1 15780 I 8737 Envelope loss/ga 12 a) Infiltration 6935 662 2961 283 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 3000 1500 Subtotal(lines 6 to 13) 55120 31433 18741 11210 4 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 55120 31433 18741 11210 15 Duct loads 17% 29% 9545 9127 10% 7% 1878 769 II Aotaequo dl(cfm) I I I 61947 409401 I I 20597I 11599I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Pk wriyFstsaoft- 2020-Dec-2110:01:36 " " • _. Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE - wrightsoft Right-J® Worksheet Job: Entire House Date: Dec 18,2020 By: 1 Room name unit#2 2 Exposed wall 229.5 ft 3 Room height 8.0 ft d 4 Room dimensions 5 Room area 1440.3 ft' 1 I I I I - 1 Ty Construction U-value Or HTM Area (ft') Load Area Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat I Cool I Gross N/P/S Heat I Cool Gross I N/P/S Heat I Cool 6 Vy 12A-0sw 0.240 ne 14.54 5.64 189 165 2392 928 4A5-2ov 0.470 ne 28.48 24.01 24 0 684 576 11P0 0.290 ne 17.57 6.82 0 0 0 0 12B-0sw 0.097 ne 5.88 2.05 0 0 0 0 11 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 Vy 12A-0sw 0.240 se 14.54 5.64 580 478 6952 2696 -G 4A5-20v 0.470 se 28.48 30.00 102 0 2905 3060 12B-osw 0.097 se 5.88 2.05 0 0 0 0 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 D 11P0 0.290 se 17.57 6.82 0 0 0 0 12A-Osw b 0.240 sw 14.54 5.64 328 253 3680 1427 10D-v 0.490 sw 29.69 21.72 42 0 1247 912 4A5-20v 0.470 sw 28.48 30.00 12 0 342 360 11P0 0.290 sw 17.57 6.82 21 21 369 143 HD12B-osw 0.097 sw 5.88 2.05 0 0 0 0 Ci 4A5-2ov 0.470 sw 28.48 30.00 0 0 0 0 11P0 0.290 sw 17.57 6.82 0 0 0 0 12A-0sw 0.240 nw 14.54 5.64 756 669 9730 3773 7 2 4A5-20v 0.470 nw 28.48 24.01 66 0 1880 1585 11P0 0.290 nw 17.57 6.82 21 21 369 143 128-0sw 0.097 nw 5.88 2.05 0 0 0 0 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 957 957 1855 2051 F 19A-Obsto 0.368 - 7.26 1.29 0 0 0 0 6 1 c)AED excursion 0 Envelope loss/gain I 324051 17654 12 a) Infiltration 3974 379 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 3 690 Appliances/other 1500 Subtotal(lines 6 to 13) 36378 20223 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 36378 20223 15 Duct loads 21% 41% 7667 8358 Total room load 41350 283501 Air required(cfm) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +}f wvigil*twirl• 2020-Dec-21 10:01:36 Rig ht-Suite®Universal 2019 19.0.20 RSU15588 Page 2 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE lie- wrightsoft Right-J® Worksheet Job: unit#1 Date: Dec 18,2020 By: 1 Room name unit#1 1 bed#1 2 Exposed wall 155.0 ft 28.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 210.0 ft 5 Room area 1286.0 ft' 210.0 ft' I T Construction U-value Or HTM Area ft' Load Area ft' Load y number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) I1 Heat I Cool Gross I N/P/S Heat I Cool Gross N/P/S Heat Cool 1 6 12A-Osw 0.240 ne 14.54 5.64 148 115 1673 649 0 0 0 0 4A5-20v 0.470 ne 28.48 24.01 12 0 342 288 0 0 0 0 11P0 0.290 ne 17.57 6.82 21 21 369 143 0 0 0 0 12B-Osw 0.097 ne 5.88 2.05 164 97 570 199 112 80 470 164 11 4A5-20v 0.470 ne 28.48 24.01 46 0 1310 1105 32 0 911 768 D 11P0 0.290 ne 17.57 6.82 21 21 369 143 0 0 0 0 Vy 12A-0sw 0.240 se 14.54 5.64 188 158 2298 891 0 0 0 0 I-G 4A5-20v 0.470 se 28.48 30.00 30 0 854 900 0 0 0 0 VLg12B-05w 0.097 se 5.88 2.05 328 259 1522 530 112 88 517 180 4A5-20v 0.470 se 28.48 30.00 48 0 1367 1440 24 0 684 720 11P0 0.290 se 17.57 6.82 21 21 369 143 0 0 0 0 VVV���lll 12A-Osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 � G 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12B-0sw 0.097 sw 5.88 2.05 164 131 770 268 0 0 0 0 4A5-2ov 0.470 sw 28.48 30.00 12 0 342 360 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 21 21 369 143 0 0 0 0 Vy 12A-0sw 0.240 nw 14.54 5.64 20 14 204 79 0 0 0 0 (! G, 4A5-2ov 0.470 nw 28.48 24.01 6 0 171 144 0 0 0 0 D 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 12B-0sw 0.097 nw 5.88 2.05 369 345 2025 705 0 0 0 0 4A5-2ov 0.470 nw 28.48 24.01 24 0 684 576 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obsto 0.368 - 7.26 1.29 24 24 172 31 0 0 0 0 0 6 c)AED excursion 15780 8737I 2583 18341 Envelope loss/gain 12 a) Infiltration 2961 283 480 46 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 1 230 Appliances/other 1500 0 Subtotal(lines 6 to 13) 18741 11210 3063 2112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 353 99 14 Subtotal 18741 11210 3416 2211 15 Duct loads 10% 7% 1878 769 10% 7% 342 152 Air equi d(cfm) I I I 20597I 11599I I I 3758 21681 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �: w f riQ‘tco ait• 2020-Dec-2110:01:36 � " "._ Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE wrightsoft Right-J® Worksheet Job: unit#1 Date: Dec 18,2020 By: 1 Room name 1 bed#1 closet 2 1 laundry 2 Exposed wall 5.5 ft 4.5 ft 3 Room height 8.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 4.5 x 5.5 ft 4.5 x 4.5 ft 5 Room area 24.8 ft' 20.3 ft' I I I I r I Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) 1 (Btuh) Heat I Cool 1 Gross I N/P/S Heat I Cool I Gross I N/P/S I Heat I Cool 6 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12B-0sw 0.097 ne 5.88 2.05 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12A-Osw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 T__tD 12B-0sw 0.097 se 5.88 2.05 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 11P0 0.290 se 17.57 6.82 0 0 0 0 0 0 0 0 hD 12A-Osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 HD 12B-Osw 0.097 sw 5.88 2.05 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 12A-0sw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 nw 5.88 2.05 44 44 259 90 41 41 238 83 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-0bsto 0.368 - 7.26 1.29 0 0 0 0 0 0 0 0 6 c)AED excursion Envelope loss/gain 259 900I 2 238 81 12 a) Infiltration 94 9 87 8 b) Room ventilation 0 0 0 0 - 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 500 Subtotal(lines 6 to 13) 353 99 325 589 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -353 -99 -325 -589 14 Subtotal 0 0 0 0 15 Duct loads 10% 7% 0 0 -0% 0% 0 0 Total room load I I 0I OI I I 0 I 0I Air required(cfm) 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -44+- w, titsoft- 2020-Dec-21 10:01:36 Right-Suite®U niversal 2019 19.0.20 RSU15588 Page 4 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE -+ wrightsoft Right-J® Worksheet Job: unit#1 Date: Dec 18,2020 By: 1 Room name 1 bathroom 1 kitchen 2 Exposed wall 0 ft 44.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 70.3 ft 20.5 x 12.0 ft 5 Room area 70.3 ft' 246.0 ft' I i I i I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S 1 Heat I Cool 1 Gross I N/P/S Heat I Cool 6 1/ 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12B-0sw 0.097 ne 5.88 2.05 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 Vy 12A-Osw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 L G 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 12B-05w 0.097 se 5.88 2.05 0 0 0 0 96 63 370 129 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 12 0 342 360 11P0 0.290 se 17.57 6.82 0 0 0 0 21 21 369 143 12A-Osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Hw 12B-0sw 0.097 sw 5.88 2.05 0 0 0 0 164 131 770 268 I G 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 12 0 342 360 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 21 21 369 143 1/' 12A-0sw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 w 12B-0sw 0.097 nw 5.88 2.05 0 0 0 0 96 84 494 172 L-G 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 12 0 342 288 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obsto 0.368 - 7.26 1.29 0 0 0 0 0 0 0 0 6 c)AED excursion 0 19 Envelope loss/gain 0 0 33981 1883 12 a) Infiltration 0 0 764 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1000 Subtotal(lines 6 to 13) 0 0 4161 2956 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 4161 2956 15 Duct loads 10% 7% 0 0 10% 7% 417 203 AirreQUomd(cfm) I I I 01 0 I I 4578 3157I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriotsis�sft• 2020-Dec-21 10:01:36 o _ - - Right-Suite®Universal 2019 19.0.20 RSU15588 Page 5 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE wrightsoft Right-J® Worksheet Job: unit#1 Date: Dec 18,2020 By: 1 Room name 1 living area 1 bed 1 closet 2 Exposed wall 28.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 275.3 ft 2.0 x 4.0 ft 5 Room area 275.3 ft' 8.0 ft' I I I 1 I - I Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) f (Btuh) 1 Heat I Cool I Gross N/P/S Heat I Cool Gross I N/P/S I Heat I Cool 6 k/ 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 C, 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12B-Osw 0.097 ne 5.88 2.05 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12A-Osw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 H 12B-05w 0.097 se 5.88 2.05 120 108 635 221 0 0 0 0 4A5-2ov 0.470 se 28.48 30.00 12 0 342 360 0 0 0 0 11P0 0.290 se 17.57 6.82 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 h 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 H12B-Osw 0.097 sw 5.88 2.05 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 w 12A-osw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 I G 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 Vy 12B-0sw 0.097 nw 5.88 2.05 104 92 541 188 0 0 0 0 L-G 4A5-2ov 0.470 nw 28.48 24.01 12 0 342 288 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obsto 0.368 - 7.26 1.29 0 0 0 0 0 0 0 0 6 c)AED excursion in 0 Envelope loss/gain 1859 1053 01 0 1 12 a) Infiltration 480 46 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2340 1099 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 325 589 0 0 14 Subtotal 2665 1688 0 0 15 Duct loads 10% 7% 267 116 10% 7% 0 0 I I TAir requi d(cfm) I I I 2985I 18940I I I O I O I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriptitsort- 2020-Dec-2110:01:36 -• -- Right-Suite®U niversal 2019 19.0.20 RSU15588 Page 6 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE 4 wrightsoft Right-J® Worksheet Job: un�t#1 Date: Dec 18,2020 By: 1 Room name 1 bed#2 1 bed#2 closet 2 2 Exposed wall 39.0 ft 0 ft 3 Room height 9.7 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 289.5 ft 5.5 x 4.0 ft 5 Room area 289.5 ft' 22.0 ft' i ' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool I Gross I N/P/S Heat Cool I Gross I N/P/S Heat I Cool I 6 try 12A-Osw 0.240 ne 14.54 5.64 148 115 1673t 649 0 0 0 0 I-pG 4A5-2ov 0.470 ne 28.48 24.01 12 0 342 288 0 0 0 0 11P0 0.290 ne 17.57 6.82 21 21 369 143 0 0 0 0 11 H 12B-05w 0.097 ne 5.88 2.05 52 17 100 35 0 0 0 0 4A5-2ov 0.470 ne 28.48 24.01 14 0 399 336 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 21 21 369 143 0 0 0 0 try 12A-0sw 0.240 se 14.54 5.64 144 114 1658 643 0 0 0 0 �G 4A5-20v 0.470 se 28.48 30.00 30 0 854 900 0 0 0 0 12B-0sw 0.097 se 5.88 2.05 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 17.57 6.82 0 0 0 0 0 0 0 0 b12A Osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Vb 12B-0sw 0.097 sw 5.88 2.05 0 0 0 0 0 0 0 0 �G 4A5-2ov 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 �D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 12A-0sw 0.240 nw 14.54 5.64 20 14 204 79 0 0 0 0 4A5-2ov 0.470 nw 28.48 24.01 6 0 171 144 0 0 0 0 D 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 Vrl 12B-osw 0.097 nw 5.88 2.05 84 84 494 172 0 0 0 0 �G 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obsto 0.368 - 7.26 1.29 24 24 172 31 0 0 0 0 6 c)AED excursion f I 6804 3-161 0 °01 Envelope loss/gain 12 a) Infiltration 961 92 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 7765 4099 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 734 256 0 0 14 Subtotal 8500 4355 0 0 15 Duct loads 10% 7% 852 299 10% 7% 0 0 Aotaequoe( m) I I I 9271I 4232 I I 0 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2 f1•I wreyhcso�'t- 2020-Dec-2110:01:36 �r - - Right-Su ite®U niv ersa1201919.0.20RSU15588 Pagel ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE 4 wrightsoft Right-J® Worksheet Job: unit#1 Date: Dec 18,2020 By: 1 Room name 1 bed#2 bath 1 stairway 2 Exposed wall 0 ft 5.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 98.0 ft 4.0 x 5.5 ft 5 Room area 98.0 ft' 22.0 ft' I I I I i I Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S I Heat I Cool 6 1/ 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 ��-� --DDD 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12B-0sw 0.097 ne 5.88 2.05 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 17.57 6.82 0 0 0 0 0 0 0 0 12A-Osw 0.240 se 14.54 5.64 0 0 0 0 44 44 640 248 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 12B-0sw 0.097 se 5.88 2.05 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 17.57 6.82 0 0 0 0 0 0 0 0 12A-osw 0.240 sw 0.00 0.00 0 0 0 0 0 0 0 0 10D-v 0.490 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12B-05w 0.097 sw 5.88 2.05 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 12A-osw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 V 12B-osw 0.097 nw 5.88 2.05 0 0 0 0 0 0 0 0 L-( 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-0bsto 0.368 - 7.26 1.29 0 0 0 0 0 0 0 0 0 -1 6 Envelope loss/gain i I 01 0 640 I 247I 12 a) Infiltration 0 0 94 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 0 734 256 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -734 -256 14 Subtotal 0 0 0 0 15 Duct loads 10% ph 0 0 10% 7% 0 0 Totalrequire roomd loa(cdm) I I I OI 0I I I 0 I 0 I Air Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -14- wroptitsoft- 2020-Dec-2110:01:36 Rig ht-Suite®U niv ersal 2019 19.0.20 RSU 15588 Page 8 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE wrightsoft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name unit#2 2 bed#2 closet 2 Exposed wall 229.5 ft 7.0 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 2.0 x 5.0 ft 5 Room area 1440.3 ft' 10.0 ft' r I I I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool Gross N/P/S I Heat I Cool I Gross I N/P/S Heat I Cool 6 Vy 12A-05w 0.240 ne 14.54 5.64 189 165 2392 928 16 16 233 90 4A5-2ov 0.470 ne 28.48 24.01 24 0 684 576 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 Vy 12A-Osw 0.240 se 14.54 5.64 580 478 6952 2696 0 0 0 0 � G 4A5-2ov 0.470 se 28.48 30.00 102 0 2905 3060 0 0 0 0 12B-Osw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 14.54 5.64 328 253 3680 1427 0 0 0 0 10D-v 0.490 sw 29.69 21.72 42 0 1247 912 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 12 0 342 360 0 0 0 0 h 11P0 0.290 sw 17.57 6.82 21 21 369 143 0 0 0 0 HD 12B-Osw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 w 12A-0sw 0.240 nw 14.54 5.64 756 669 9730 3773 40 40 582 226 4 G 4A5-20v 0.470 nw 28.48 24.01 66 0 1880 1585 0 0 0 0 1 D 11P0 0.290 nw 17.57 6.82 21 21 369 143 0 0 0 0 w 12B-Osw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 �- G 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 957 957 1855 2051 0 0 0 0 F 19A-Obsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 Envelope loss/gain 1 c)AED excursion 0 7 32405 17654 814 309 12 a) Infiltration 3974 379 120 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 1500 0 Subtotal(lines 6 to 13) 36378 20223 935 321 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -935 -321 14 Subtotal 36378 20223 0 0 15 Duct loads 21% 41% 7667 8358, 18% 11% 0 0 AotaegUomdl(afdm) I I I 41350I 28350I I I O I 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. P$h wr pf-atsotht- 2020-Dec-21 10:01:36 • Right-Suite@ U niversal 2019 19.0.20 RSU15588 Page 9 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE wrightsoft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name 2 half bath 2 closet 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 5.5 x 5.0 ft 2.5 x 3.5 ft 5 Room area 27.5 ft' 8.8 ft' I i I I I I Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat I Cool 1 Gross N/P/S 1 Heat I Cool I Gross N/P/S I Heat Cool 6 V 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12B-0sw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 12B-0sw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 sw 14.54 5.64 0 0 0 0 0 0 0 0 10D-v 0.490 sw 29.69 21.72 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 HD 12B-0sw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 nw 17.57 6.82 0 0 0 0 0 0 0 0 Vy 12B-0sw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 I-G 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 0 0 0 0 0 0 0 0 F 19A-Obsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion Envelope loss/gain I 01 0 0 0 0 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 26% 49% 0 0 26% 49% 0 0 Total roomrequired load(cfm) I I I 0 0I 0 0 I I 0 0I 0 0I Air Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vie rfytilscoT[• 2020-Dec-21 10:01:36 Right-Suite®Universal 2019 19.0.20 RSU15588 Page 10 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE * wrightsaft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name 2 liv/din/kitchen 2 bed#1 2 Exposed wall 67.5 ft 31.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 406.8 ft 1.0 x 191.8 ft 5 Room area 406.8 ft' 191.8 ft' I I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Bt uh/f t'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool I Gross I N/P/S I Heat I Cool I Gross I N/P/S Heat I Cool I 6 w 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 96 84 1222 474 )---G 4A5-20v 0.470 ne 28.48 24.01 0 0 0 0 12 0 342 288 LLL--DDD 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 • 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 1.......G12A-0sw 0.240 se 14.54 5.64 196 160 2327 902 132 102 1483 575 4A5-20v 0.470 se 28.48 30.00 36 0 1025 1080 30 0 854 900 V.1 12B-Osw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 10D-v 0.240 sw 14.54 5.64 164 131 1905 739 0 0 0 0 0.490 sw 29.69 21.72 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 28.48 30.00 12 0 342 360 0 0 0 0 11P0 0.290 sw 17.57 6.82 21 21 369 143 0 0 0 0 bVy 12B-osw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 �Cp 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 \0' 12A-Osw 0.240 nw 14.54 5.64 180 135 1963 761 20 14 204 79 ) G 4A5-2ov 0.470 nw 28.48 24.01 24 0 684 576 6 0 171 144 II-I DDD 11P0 0.290 nw 17.57 6.82 21 21 369 143 0 0 0 0 VL12B-0sw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 �C 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 41 41 80 88 192 192 372 411 F 19A-obsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -122 -551 Envelope loss/gain 9065 4671 4648 2816 12 a) Infiltration 1158 111 532 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 1000 0 Subtotal(lines 6 to 13) 10223 5782 5180 3097 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10223 5782 5180 3097 15 Duct loads 26% 49% 2619 2810 26% 49% 1327 1505 TAotaequomdl(cfm) I 1 123849241 85921 406 I I 6199 46021217 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. {}� wrivarstacoTt- 2020-Dec-2110:01:36 .. Right-Suite®Universal 2019 19.0.20 RSU15588 Page 11 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE -41- wrightsoft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name 2 bed#1 bath 2 bed#1 closet 2 Exposed wall 16.5 ft 7.0 ft 3 Room height 9.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.5 x 8.0 ft 8.5 x 7.0 ft 5 Room area 68.0 ft' 59.5 ft' I I I I I I Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Btuh/ft-°F) (Btuh/ft) or perimeter (ft) (Btuh) +I or perimeter (ft) (Btuh) Heat I Cool I Gross N/P/S Heat I Cool Gross I N/P/S Heat I Cool 1 6 try 12A-0sw 0.240 ne 14.54 5.64 77 65 938 364 0 0 0 0 II-(_ 4A5-2ov 0.470 ne 28.48 24.01 12 0 342 288 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 • 12A-0sw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 • 12B-0sw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 14.54 5.64 0 0 0 0 0 0 0 0 10D-v 0.490 sw 29.69 21.72 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 • 12B-osw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 nw 14.54 5.64 72 72 1047 406 56 56 814 316 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 �D 11P0 0.290 nw 17.57 6.82 0 0 0 0 0 0 0 0 W 12B-osw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 68 68 132 146 60 60 115 128 F 19A-0bsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 1 c)AED excursion -21 9 Envelope loss/gain 24591 1183 I 930 434 12 a) Infiltration 319 30 120 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2777 1213 1050 445 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2777 1213 1050 445 15 Duct loads -0% 0% 0 0 26% 49% 269 216 I Air requi d(cfm) I I I 2785I 1257I I I 1319 40I 631 Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. 4 wrlIptstsoTt- 2020-Dec-21 10:01:36 •- Right-Suite®Universal 2019 19.0.20 RSU15588 Page 12 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Pk wrightsoft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name 2 laundry 2 hallway 2 Exposed wall 0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 3.5 x 3.5 ft 1.0 x 103.8 ft 5 Room area 12.3 ft' 103.8 ft' i I I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Bt uh/f t'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool Gross 1 N/P/S Heat I Cool I Gross N/P/S Heat I Cool 6 Vy 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 12A-Osw 0.240 se 14.54 5.64 0 0 0 0 112 100 1454 564 I-G 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 12 0 342 360 W 12B-Osw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 C 4A5-2ov 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 14.54 5.64 0 0 0 0 0 0 0 0 10D-v 0.490 sw 29.69 21.72 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 b12B-0sw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 nw 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 0 0 0 0 D 11P0 0.290 nw 17.57 6.82 0 0 0 0 0 0 0 0 Vy 12B-0sw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 �G 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 12 12 24 26 104 104 201 222 F 19A-Obsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 I 6 Envelope loss/gain c)AED excursion 11 23 24 15 1997 111 70 12 a) Infiltration 0 0 240 23 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 500 0 • Subtotal(lines 6 to 13) 24 515 2238 1193 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -24 -515 35 485 14 Subtotal 0 0 2273 1678 15 Duct loads 26% 49% 0 0 26% 49% 582 815 Totalrequir roomed(c loa ) 0 d I I I OI 0 I I 28551 24931 Air fm 0 87 118 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �4►- wriyiv taw Tt- 2020-Dec-2110:01:36 -• - Right-Suite®Universal 2019 19.0.20 RSU15588 Page 13 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE -+}+- wrightsoft Right-J® Worksheet Job: unit#2 Date: Dec 18,2020 By: 1 Room name 2 closet 2 2 bed2 bath 2 Exposed wall 0 ft 16.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 2.5 x 6.5 ft 8.5 x 14.0 ft 5 Room area 16.3 ft' 119.0 ft' I I I I i I Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') I Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross N/P/S I Heat I Cool 1 6 VI/ 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 pG 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-20v 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 12A-osw 0.240 se 14.54 5.64 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 28.48 30.00 0 0 0 0 0 0 0 0 12B-osw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 14.54 5.64 0 0 0 0 20 20 291 113 10D-v 0.490 sw 29.69 21.72 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 HD 12B-Osw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-20v 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 nw 14.54 5.64 0 0 0 0 112 100 1454 564 4A5-2ov 0.470 nw 28.48 24.01 0 0 0 0 12 0 342 288 D 11P0 0.290 nw 17.57 6.82 0 0 0 0 0 0 0 0 Vy 12B-osw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 I-C 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 16 16 32 35 119 119 231 255 F 19A-Obsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -1I 32 341 2318 13911 • Envelope loss/gain 12 a) Infiltration 0 0 283 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 32 34 2601 1338 - Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -32 -34 0 0 14 Subtotal 0 0 2601 1338 15 Duct loads 26% 49%. 0 0 26% 49% 666 650 AirregUomd(cfm) I I I OI OI I 1 3267 100I 1994I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - 41- wriytttsott- 2020-Dec-21 10:01:36 Right-Suite®Universal 2019 19.0.20 RSU15588 Page 14 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE wrightsoft Right-J® Worksheet Job: unit?* By: Dec 18,2020 By: 1 Room name 2 bed#2 2 nd fir entry 2 Exposed wall 52.0 ft 18.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 344.8 ft 4.0 x 18.0 ft 5 Room area 344.8 ft' 72.0 ft' I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load ' number I(Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat I Cool Gross I N/P/S I Heat I Cool I Gross `I N/P/S I Heat I Cool 6 11 12A-0sw 0.240 ne 14.54 5.64 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 28.48 24.01 0 0 0 0 0 0 0 0 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 w 12B-Osw 0.097 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 I-G 4A5-2ov 0.470 ne 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 Vy 12A-0sw 0.240 se 14.54 5.64 140 116 1687 654 0 0 0 0 _( 4A5-20v 0.470 se 28.48 30.00 24 0 684 720 0 0 0 0 12B-0sw 0.097 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 se 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 12A-Osw 0.240 sw 14.54 5.64 144 102 1483 575 0 0 0 0 10D-v 0.490 sw 29.69 21.72 42 0 1247 912 0 0 0 0 4A5-20v 0.470 sw 28.48 30.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 17.57 6.82 0 0 0 0 0 0 0 0 Hw 12B-0sw 0.097 sw 0.00 0.00 0 0 0 0 0 0 0 0 I G 4A5-2ov 0.470 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 12A-05w 0.240 nw 14.54 5.64 132 132 1920 744 144 120 1745 677 �-G 4A5-20v 0.470 nw 28.48 24.01 0 0 0 0 24 0 684 576 II -DD 11P0 0.290 nw 17.57 6.82 0 0 0 0 0 0 0 0 Vy 126-0sw 0.097 nw 0.00 0.00 0 0 0 0 0 0 0 0 �G 4A5-2ov 0.470 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.94 2.14 345 345 669 739 0 0 0 0 F 19A-0bsto 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 1 76901 42511 24291 1459 Envelope loss/gain 12 a) Infiltration 892 85 309 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 8582 4796 2738 1489 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 20 65 935 321 14 Subtotal 8602 4861 3672 1809 15 Duct loads 26% 49% 2204 2362 -0% 0% 0 0 Totalrequir roomed load(cfm) I I I 108061 72231 I I 36721 1809 Air 331 341 113 85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ali- tour r.yhtsoft- 2020-Dec-2110:01:36 Right-Suite®Universal 2019 19.0.20 RSU15588 Page 15 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE basement Sup Riser 6 " '8 "114x8 '10x8_I �14 " Sup Riser basemen 7 „ '6 x 8 LY'ft"ftr7,J 7 " Job#: Scale: 1 : 71 Performed for: Page 1 t Rice St RigitSuite®U riversal 2019 Salem,Ma 19.0.20 RSU15588 2020-Dec-21 10:03:28 ...ng 11 rice st salem 12182020.rup N 1 st floor Sup Riser 6 " 1 ►; '' 118cfm 2 nd flr enti - 1 bed#' 1 bed 1 I losE 1 bed#1 cloE :. Riser _.(-_ basement stair 1 laundr bathroon Z 597 cfm _ 90 cfm 1 living arei \ I -0/79 cfm ill , 1 kitche 79 cfm ri Job#: Scale: 1 : 71 Performed for: Page 2 11 Rice St RightSuite®U riversal 2019 Salem,Ma 19.0.20 RSU15588 2020-Dec-21 10:03:28 ...ng 11 rice st salem 12182020.rup N 2 nd floor Sup Riser "1 6 " 1.1 E_ l _ 2 bed#2 ao�� P 135 cfm Sup Riser 1 bed#; 6 " 113 cfm 135 cfm 2 nd flr enti TP Sup Riser —, --:—..„...) bed#2 closet 1st 2 close 1 bed#2 bat • 2 half bat Sup Riser Sup Riser J6 " 7 „ r 135 cfm 2 , 135 cfm 2 liv/din/kitche Sup Riser 6 " 135 cfm r_.I t Job#: Scale: 1 : 71 Performed for: Page 3 11 Rice St Ri J1tSuite®U riversal 2019 Salem,Ma 19.0.20 RSU15588 2020-Dec-21 10:03:28 ...ng 11 rice st salem 12182020.rup N 3 rd floor 85 cfm 1 I t 1 6 „ 3 109 cfm f - 7 �L 2 bed#" eat _ Sup Riser 2 bed#1 6 " 109 cfm 2 bed#1 cl s:/ 7 „ 40 F'_"1 _ 4 7 2 hallwa' c laullui 118 cfm 2 bed2 bat I. '- 100 cf — — Mosel 1350 cfm Sup Riser _ 7 " R ) 17 „ 6 " 7 „ 171 cfm h 20 „ 2 bed#; Sup Riser 28x8 6 „ 6 " Nr-- 171 cfm Job#: Scale: 1 : 71 Performed for: Page 4 11 Rice St RightSuite®U riversa12019 Salem,Ma 19.0.20 RSU15588 2020-Dec-21 10:03:28 ...ng 11 rice st salem 12182020.rup wri htsoft Duct System Summary Job: 9 Date: Dec 18,2020 unit#1 By: Project Information For: 11 Rice St,Salem, Ma Heating Cooling External static pressure 0.80 in H2O 0.80 in H2O Pressure losses 0.38 in H2O 0.38 in H2O Available static pressure 0.42 in H2O 0.42 in H2O Supply/return available pressure 0.328/0.092 in H2O 0.328/0.092 in H2O Lowest friction rate 0.095 in/100ft 0.095 in/100ft Actual air flow 597 cfm 597 cfm Total effective length(TEL) 442 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk 1 bed#1 c 2362 109 118 0.152 6.0 Ox 0 VIFx 16.0 200.0 st4A 1 bed#2 h 4676 135 116 0.150 6.0 Ox 0 ShMt 8.5 210.0 st4 1 bed#2-A h 4676 135 116 0.112 7.0 Ox 0 ShMt 37.5 255.0 st3 1 kitchen c 1579 66 79 0.095 7.0 Ox 0 VIFx 54.5 290.0 st3A 1 kitchen-A c 1579 66 79 0.097 7.0 Ox 0 VIFx 37.0 300.0 st3A 1 living area c 1804 85 90 0.102 7.0 Ox 0 VIFx 42.0 280.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3A Peak AVF 133 157 0.095 472 7.0 8 x 6 ShtMetl st3 st3 Peak AVF 353 363 0.095 654 9.5 8 x 10 ShtMetl st1 st4 Peak AVF 244 234 0.150 700 8.0 0 x 0 ShtMetl st1 st4A Peak AVF 109 118 0.152 600 6.0 0 x 0 ShtMetl st4 st1 Peak AVF 597 597 0.095 768 11.5 8 x 14 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 597 597 97.0 0.095 558 14.0 Ox 0 ShMt Wriyhtsoft' 2020-Dec-21 10:01:38 ._.. ........___....,.... Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 ...H VAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Duct System SummaryJob-Pie- -Pi e- wrightsofty Date: Dec 18,zozo unit#2 By: Project Information For: 11 Rice St, Salem, Ma Heating Cooling External static pressure 0.80 in H2O 0.80 in H2O Pressure losses 0.35 in H2O 0.35 in H2O Available static pressure 0.45 in H2O 0.45 in H2O Supply/return available pressure 0.302/0.148 in H2O 0.302/0.148 in H2O Lowest friction rate 0.146 in/100ft 0.146 in/100ft Actual air flow 1350 cfm 1350 cfm Total effective length(TEL) 308 ft Supply Branch Detail Table I / Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk 2 bed#1 c 2301 100 109 0.146 7.0 Ox 0 VIFx 46.5 160.0 st2 2 bed#1 bath h 2777 85 57 0.203 6.0 Ox 0 VIFx 43.5 105.0 st2 2 bed#1 closet h 1319 40 31 0.154 4.0 Ox 0 ShMt 31.5 165.0 st2 2 bed#1-A c 2301 100 109 0.155 7.0 Ox 0 VIFx 54.5 140.0 st2 2 bed#2 c 3611 166 171 0.159 8.0 Ox 0 VIFx 14.5 175.0 st2 2 bed#2-A c 3611 166 171 0.151 7.0 Ox 0 ShMt 25.0 175.0 st2 2 bed2 bath h 3267 100 94 0.154 6.0 Ox 0 ShMt 21.5 175.0 st2 2 hallway c 2493 87 118 0.148 7.0 Ox 0 VIFx 28.5 175.0 st2 2 liv/din/kitchen c 2865 131 135 0.158 6.0 Ox 0 ShMt 16.0 175.0 st2 2 liv/din/kitchen-A c 2864 131 135 0.151 7.0 Ox 0 VIFx 24.5 175.0 st2 2 liv/din/kitchen-B c 2864 131 135 0.159 6.0 Ox 0 ShMt 14.5 175.0 st2 2 nd flr entry h 3672 113 85 0.160 6.0 Ox 0 ShMt 38.0 150.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 1350 1350 0.146 868 14.3 8 x 28 ShtMetl -l1 - wriyhtsoft• 2020-Dec-21 10:01:38 t .. .,..... Right-Suite®U niversal 2019 19.0.20 RSU15588 Page 2 ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox 0 1350 1350 101.5 0.146 619 20.0 Ox 0 ShMt ' wrightsoft• 2020-Dec-21 10:01:38 � � Right-Suite®Universal 2019 19.0.20 RSU15588 Page 3 /fi+�+llk ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE Static Pressure and Friction Rate Job: WPIghtSOft" Date: Dec 18,2020 unit#1 By: Project Information For: 11 Rice St,Salem, Ma Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.80 0.80 Pressure losses Coil 0.15 0.1 Heat exchanger 0.03 0.02 Supply diffusers 0.03 0.02 Return grilles 0.03 0.02 Filter 0.11 0.11 Humidifier 0.03 0.02 Balancing damper 0 0 Other device 0 0 Available static pressure 0.42 0.42 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 15 17 Measured length of trunk 40 0 Equivalent length of fittings 290 80 Total length 345 97 Total effective length 442 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.095 OK 0.095 OK Return Ducts 0.095 OK 0.095 OK Fitting Equivalent Length Details Supply 4AD=60,2A0=35, 1201=10,9K=65, 911=85, 1A=35:TotalEL=290 Return 6M=20,8AE=10,8AE=10, 5D=40:TotalEL=80 -41111- wrightsoft 2020-Dec-2110:01:38 � Right-Suite®Universal 2019 19.0.20 RSU15588 Page 1 /'t~+>� ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE -p - 9 Static Pressure and Friction Rate Job: wrightsoft Date: Dec 18,2020 unit#2 By: Project Information For: 11 Rice St,Salem, Ma Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.80 0.80 Pressure losses Coil 0.14 0.14 Heat exchanger 0.03 0.02 Supply diffusers 0.04 0.04 Return grilles 0.03 0.02 Filter 0.11 0.11 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.45 0.45 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 14 32 Measured length of trunk 33 0 Equivalent length of fittings 160 70 Total length 207 102 Total effective length 308 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.146 OK 0.146 OK Return Ducts 0.146 OK 0.146 OK Fitting Equivalent Length Details Supply 4AD=60,2A3=65, 1A=35:TotalEL=160 Return 8AE=10,6M=20, 5D=40:TotalEL=70 W I'il U' ° ' 2020-Dec-21 10:01:38 Rig hl-Su ite@ Universal 2019 19.0.20 RSU 15588 Page 2 �+� ...HVAC\rpm plumbing 11 rice st salem 12182020.rup Calc=MJ8 Front Door faces:NE