BOA_1 Amanda Way - PlansSTAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:23 AMG-01 COVER Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 Sheet List Sheet Number Sheet Name GENERAL G-01 COVER EXISTING CONDITIONS / DEMOLITION D-01 EXISTING CONDITIONS / DEMOLITION FLOOR PLANS & INTERIOR DEMOLITION ELEVATION ARCHITECTURAL A-01 LEVEL 2 & 3 FLOOR PLANS & REFLECTED FLOOR PLANS SHOWING POWER & LIGHTING LAYOUTS A-02 LEVEL 1 FLOOR PLAN, FRAMING LAYOUTS DIAGRAMS & INTERIOR ELEVATION A-03 ROOF PLAN & BUILDING SECTION A-04 TYPICAL DETAILS A-05 TYPICAL DETAILS A-06 TYPICAL DETAILS A-07 EXTERIOR PERSPECTIVES GENERAL: 1. ALL DIMENSIONS SHALL BE VERIFIED FOR ACCURACY AND COORDINATION WITH THE CONTRACT DRAWINGS PRIOR TO ACTUAL CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES PRIOR TO THE START OF WORK. CONTRACTOR SHOULD INFORM DESIGNER OF ANY DISCREPANCIES IN THE DOCUMENTS OR IN CONFLICT WITH THE CODES. ERRORS, CONFLICTS, OR DISCREPANCIES NOTED IN THE DRAWINGS OR SPECIFICATIONS SHALL BE CALLED TO THE IMMEDIATE ATTENTION OF THE DESIGNER FOR INTERPRETATION BEFORE WORK IS TO START. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS. 2. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY SHORING AND BRACING FOR THE PROJECT DURING CONSTRUCTION. 3. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION INCLUDING, BUT NOT LIMITED TO, ALL PLUMBING, ELECTRICAL AND FIRE DEPARTMENT CODES AND REGULATIONS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 5. CONTRACTOR TO COORDINATE STRUCTURAL FRAMING WITH ELECTRICAL, PLUMBING, AND MECHANICAL WORK. 6. CONTRACTOR IS RESPONSIBLE FOR THE PROPER OPERATION OF ALL SYSTEMS AND THE COORDINATION OF ALL SYSTEMS AND TRADES. 7. THE DESIGNER MAKES NO GUARANTEES OR WARRANTIES, EXPRESS OR IMPLIED THAT THESE DOCUMENTS WILL BE WITHOUT ERROR, OMISSIONS, OR FLAWS, OR THAT THE WORK WILL CONFORM TO THE HIGHEST IMAGINABLE STANDARDS. DEMOLITION: 1. THE GENERAL CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE PROJECT SITE AND EXISTING CONDITIONS AND SHALL BE RESPONSIBLE FOR DEMOLITION, REMOVAL AND RELOCATION OF ALL EXISTING WORK NECESSARY FOR AND INCIDENTAL TO NEW CONSTRUCTION. 2. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY DISCREPANCY BETWEEN ASSUMED AND ACTUAL EXISTING CONDITIONS. 3. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING AND PROVIDING ALL NECESSARY SHORING TO PREVENT DAMAGE TO EXISTING AND/OR NEW WORK DURING DEMOLITION AND CONSTRUCTION ACTIVITIES. 4. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING OF EXISTING WORK WHICH MUST BE TEMPORARILY REMOVED TO PERFORM THE WORK INDICATED IN THESE DRAWINGS. SUCH REPAIRS SHALL RESTORE EXISTING WORK TO ITS ORIGINAL CONDITION. 5. THE GENERAL CONTRACTOR SHALL ERECT TEMPORARY BARRICADES AS NECESSARY TO PROTECT NEW AND/OR EXISTING WORK AND OCCUPIED AREAS FROM DUST, DEBRIS AND DAMAGE DURING CONSTRUCTION ACTIVITIES. 6. THE GENERAL CONTRACTOR SHALL CUT AND PATCH ADJACENT FINISHES TO LOGICAL BREAK IN PLANE ALLOWING FOR MINIMAL SEAMS BETWEEN EXISTING AND NEW. CEILING HEIGHT: 1. HABITABLE SPACES SHALL HAVE A CLEAR HEIGHT OF NOT LESS THAN 7'-0" NOT MORE THAN 50% OF REQUIRED FLOOR AREA OF A SPACE IS PERMITTED TO HAVE A SLOPED CEILING LESS THAN 7'-0" WITH NO PORTION LESS THAN 5'-0". BATHROOMS SHALL HAVE A MINIMUM CEILING HEIGHT WITH NO PORTION BEING LOWER THAN 6'-8" ABOVE THE FIXTURES AND ITS FRONT CLEARANCE AREA. IRC R305. EGRESS: 1. EACH SLEEPING ROOM SHALL BE PROVIDED WITH AN ESCAPE OPENING: NET CLEAR OPENING OF 5.7 SF. THE NET CLEAR OPENING HEIGHT SHALL BE 24" AND THE NET CLEAR OPENING WIDTH SHALL BE 20". THE SILL HEIGHT SHALL NO HIGHER THAN 44" ABOVE THE FINISHED FLOOR. REFER TO IRC R310.1. FIRE PROTECTION SYSTEM: 1. EACH BEDROOM, AND OUTSIDE SLEEPING ROOM, AND ON EACH STORY TO BE PROVIDED WITH A SMOKE DETECTOR, SMOKE DETECTOR POWER SOURCES TO BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND IRC R313. ALL ALARM DEVICES TO BE INTERCONNECTED PER IRC R313.2. FRAMING TO HAVE FIREBLOCKING PER IRC R602.8. PROVIDE DRAFTSTOPPING AT CONCEALED SPACES OVER 1000 SF PER IRC R502.12. NATURAL LIGHTING: 1. ALL HABITABLE ROOMS SHALL HAVE AN AGGREGATE GLAZING AREA OF NOT LESS THAN 8% OF THE FLOOR AREA OF THE ROOM PER IRC R303. GLAZED AREAS ARE NOT REQUIRED WHERE ARTIFICIAL LIGHTING IS PROVIDED. VENTILATION SYSTEM: 1. IN HABITABLE ROOMS NOT PROVIDED WITH AN OPENABLE EXTERIOR OPENING OF AT LEAST 4% OF THE FLOOR AREA A MECHANICAL VENTILATION SYSTEM MUST BE PROVIDED THAT PROVIDES A MINIMUM 0.35 AIR CHANGES PER HOUR PER IRC R303.1. BATHROOM FANS SHALL BE 50 CFM VENTING TO THE EXTERIOR. REFER TO IRC303 AND MASS. MECHANICAL CODE AND INDOOR AIR QUALITY CODE. * Values are not applicable to this project: The following values are provided or exceeded in compliance with Table R402.1.2 above; As noted throughout the Construction Documents: Fenestration: < U-0.30 Ceiling/Roof: R-49 Walls (Wood Framed): >R-21 Air Barrier & Insulation installed in accordance with Table R402.4.1.1 of 2015 IECC. Mechanical, Electrical and Plumbing Systems are Design/Build. Compliance Documentation for these systems shall be provided to the Salem Building Department by each Subcontractor. ** TYPICAL ABBREVIATIONS V.I.F.VERIFY IN FIELD PTD PAINTED TYP TYPICAL UON UNLESS OTHERWISE NOTED WD WOOD CL CENTER LINE CLR CLEAR WOOD: 1. ALL STRUCTURAL LUMBER AND THEIR CONNECTIONS SHALL CONFORM TO THE LATEST EDITION OF THE NDS "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" AND SUPPLEMENT "DESIGN VALUES FOR WOOD CONSTRUCTION." 2. ALL STRUCTURAL WOOD FRAMING SHALL BE SPRUCE- PINE-FIR NO.2 OF BETTER WITH Fb-875 PSI; Fv-135; E-1,400,000 PSI. 3. ALL FASTENING SHALL BE IN ACCORDANCE WITH THE FASTENING SCHEDULE PER THE MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION.. 4. STRUCTURAL WOOD MEMBERS SHALL NOT BE CUT, NOTCHED, OR PIERCED IN EXCESS OF THE LIMITATIONS SPECIFIED IN THE MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION.. 5. PLYWOOD SHEATHING AT ROOF SHALL SPAN PERPENDICULAR TO ROOF FRAMING, UNLESS OTHERWISE NOTED. 6. PROVIDE 2X WOOD BLOCKING AT ALL UNSUPPORTED PLYWOOD EDGES. 7. ALL STEEL HARDWARE SHALL BE HOT-DIPPED GALVANIZED. PROVIDE AND INSTALL STAMPED AND FABRICATED STEEL OF THE TYPE INDICATED AS REQUIRED IN THE CONSTRUCTION DOCUMENTS. FASTENERS SHALL BE THOSE FURNISHED BY THE MANUFACTURER FOR THE SPECIFIC USE. FASTENERS SHALL BE FULLY DRIVEN IN ALL HOLES IN THE HANGER OR ANCHOR. "SIMPSON" HANGERS, CONFORMING TO THE REQUIREMENTS INDICATED, SHALL BE PROVIDED. WINDOWS: 1. NEW WINDOWS SHALL HAVE A U-VALUE EQUAL TO 0.30 OR LOWER. 2. GLAZING AT “HAZARDOUS LOCATIONS”AS DEFINED BY IRC 2015, SECTION 308.4 (WITH MASSACHUSETTS AMENDMENTS) SHALL BE TEMPERED. 3. FURNISH REMOVABLE INSECT SCREENS FOR ALL OPERABLE UNITS. HIGH TRANSPARENCY OPTION. 4. WINDOWS SHALL BE FLASHED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. FILL CAVITIES BETWEEN ROUGH OPENINGS AND FRAMES WITH LOW EXPANSION FOAM INSULATION. 5. INCLUDE INTERIOR JAMB EXTENSIONS APPROPRIATE TO THICKNESS OF EXTERIOR WALLS AT EACH LOCATION AS REQUIRED. 6. UNITS SHALL BE GLAZED WITH INSULATED, ADVANCE LOW- E, ARGON FILLED, DOUBLE PANE SEALED GLASS UNITS, TO MEET THE REQUIREMENTS OF THE MASSACHUSETTS ENERGY CODE FOR STRETCH CODE COMMUNITIES. ENTIRE WINDOW UNIT, INCLUDING GLAZING SHALL BE TESTED BY MANUFACTURER TO MEET ALL APPLICABLE REQUIREMENTS FOR THE WIND SPEED AND COMPONENT PRESSURE ZONES AS INDICATED WITH THE LATEST AMENDMENTS TO 780 CMR, 9TH EDITION AND THE 2015 IRC. WINDOW MANUFACTURER TO SUPPLY ALL NECESSARY ENGINEERING AND DOCUMENTATION FOR THE WINDOW AND GLAZING SYSTEM INCLUDING CONNECTIONS AND FLASHING. TOTAL UNIT U-FACTOR SHALL NOT EXCEED 0.30. WINDOWS SHALL BE ANCHORED TO STRUCTURE USING METHOD DESCRIBED IN MANUFACTURER’S INSTALLATION AND/OR SHOP DRAWINGS. DOORS: 1. INTERIOR DOORS SHALL MATCH OTHER EXISTING DOOR PANEL DESIGN, STICKING, & HARDWARE UNLESS OTHERWISE NOTED. MARK DATE DESCRIPTION UP DN UP MASTER BEDROOM MASTER BATH BATH BEDROOM BEDROOM HALL / OFFICE REMOVE DOOR & TRIM REMOVE SECTION OF WALL 3' - 6 1/4"7' - 2 3/4" ;V.I.F.D-01 2 WALK-IN CLOSET CLOSET CLOSET EXISTING MAIN CARRYING FLUSH BEAM; VERIFY LOCATION, SIZE, & TYPE IN FIELD PRIOR TO START OF ALL & ANY WORK24' - 10 1/4"35' - 0 7/8" EXISTING DUCT SHAFT REMOVE SECTION OF WALL 7' - 10 1/2"5' - 8 1/4" LIMIT DEMO TO NEAREST RISER OF EXISTING WALL REMOVE DOOR & TRIM EXISTING RAILING TO REMAIN EXTEND HALF WALL TO CEILING; COORDINTATE WITH NEW WORK REMOVE SECTION OF HALF WALL REMOVE SECTION OF ROOF; COORDINATE WITH NEW WORK; PROVIDE TEMPORARY SUPPORT 6' - 2 5/8"10' - 11 5/8"12' - 4 1/2"10' - 3 7/8" ;V.I.F.12' - 4 1/2" REMOVE (3) SECTION OF EXISTING ROOF RAFTERS; PROVIDE TEMPORARY SUPPORT REPLACE RAFTERS WITH NEW DOUBLE LVL RAFTER RETAIN EXISTING RAFTER SECTIONS REMOVE SECTION OF ROOF; COORDINATE WITH NEW WORK; PROVIDE TEMPORARY SUPPORT 35' - 0 7/8" LIVING ROOMDINING ROOM KITCHEN FAMILY ROOM PANTRY BATHROOM FOYER EXISTING MAIN CARRYING FLUSH BEAM; VERIFY LOCATION, SIZE, & TYPE IN FIELD PRIOR TO START OF ALL & ANY WORK 24' - 10 1/4"35' - 0 7/8" 13' - 0"20' - 0"EXISTING DUCT SHAFT EXISTING MAIN CARRYING BEAM; VERIFY LOCATION, SIZE, & TYPE IN FIELD PRIOR TO THE START OF ALL & ANY WORK VERIFY EXISTING LALLEY COLUMN SIZE & SPACING PRIOR TO THE START OF ALL AND ANY WORK; MUST BE 3-1/2" DIAMETER, TYP.23' - 11 1/4"34' - 0 7/8"19' - 0"48' - 7 7/8" STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:23 AMD-01 EXISTING CONDITIONS / DEMOLITION FLOOR PLANS & INTERIOR DEMOLITION ELEVATION Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 1/4" = 1'-0"1 EXISTING CONDITIONS / DEMOLITION LEVEL 2 FLOOR PLAN 1/2" = 1'-0"2 EXISTING CONDITIONS/ DEMOLITION ELEVATION OF ATTIC STAIR 1/4" = 1'-0"3 EXISTING CONDITIONS / DEMOLITION LEVEL 3 (ATTIC) FLOOR PLAN 1/4" = 1'-0"4 EXISTING CONDITIONS LEVEL 1 FLOOR PLAN 1/4" = 1'-0"5 EXISTING CONDITIONS / DEMOLITION BASEMENT FLOOR PLAN MARK DATE DESCRIPTION DN UP DN LIVING ROOM BEDROOM BATH 1 A-03 B30B30B36B36B36B36 12' - 0"12' - 11 1/8"9' - 3 1/8"1' - 0"3' - 3 1/4" 12' - 0"5' - 5 1/8"9' - 0"5' - 1 1/8" 35' - 0 7/8" 35' - 1 7/8" TILE SHOWER WALLS AND FLOOR WITH GLASS DOOR; SLOPE FLOOR 1/8" PER FOOT TO FLOOR DRAIN TILE FLOOR IN BATHROOM HOMWONWER TO SELECT FINISH FLOORING 3 DRAWER CABINET INSTALLED INTO KNEE WALL; TRIM OPENING TO MATCH EXISTING HOUSE MOLDING PROFILE DOUBLE DOOR CABINET DOUBLE DOOR CABINET DOUBLE DOOR CABINET B30B30 3 DRAWER CABINET INSTALLED INTO KNEE WALL; TRIM OPENING TO MATCH EXISTING HOUSE MOLDING PROFILE TRIM OPENING TO MATCH EXISTING HOUSE MOLDING PROFILE TRIM OPENING TO MATCH EXISTING HOUSE MOLDING PROFILE 42" WIDE VANITY CABINET WITH STONE VANITY TOP 30" WIDE TALL LINEN CABINET NOTE: ALL DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL UNLESS OTHERWISE NOTED 2X4 WOOD FRAMING AT 16" O.C., TYP. EXTERIOR WALLS TO BE 2X6 WOOD FRAMING AT 16" O.C. NEW WINDOW TO MATCH EXISTING LEVEL 2 BATHROOM WINDOW; MATCH COLOR, STYLE, & HEAD HEIGHT 10' - 3 7/8"12' - 0" EXISTING 2X6 WOOD STUD WALLS TO REMAIN; FILL CAVITIES WITH 2" CLOSED CELL SPRAY FOAM (R-13) AGAINST EXTERIOR SHEATHING; FILL REMAINDER OF WALL CAVITY WITH R-15 FIBERGLASS BATT INSULATION; TYPICAL FOR ALL EXTERIOR 2X6 WOOD FRAMED WALLS (BOTH EXISTING & NEW), TYP. 3 1/2" X 3 1/2" PSL POST3 1/2" X 3 1/2" PSL POST 9' - 3 1/2"5' - 0"4' - 3 1/2"36" HIGH WOOD RAILING TO MATCH EXISTING RAILING ON 2ND FLOOR 5' - 1 1/8" ; V.I.F. 12' - 0"V.I.F.3' - 0"32" x 80" 30" x 80" 72" x 80"V.I.F.3' - 0"LOCATION OF NON-LOAD BEARING PARTITION WALL TO BE DETERMINED BY OWNER; OWNER MAY CHOOSE TO OMIT WALL EQ EQ A-04 1 A-04 2 R EQ EQ R RR R R EQ EQ EQEQR R R R EQ 5' - 8 1/8"5' - 8 1/8"5' - 8 1/8"EQ EQEQW2 W2 EQ 6' - 1 3/4"EQ EQ 6' - 0"EQ EQ3' - 7 1/8"EQR EQ EQ W1 EQ EQ EQ EQEQEQ 3SS NOTE: ALL LIGHTING FIXTURES TO BE SELECTED BY HOMEOWNER33-WAY SWITCH AT BOTTOM OF STAIRWAYd ddEQEQR R W2 W1 3 WALL MOUNT VANITY LIGHT FIXTURE WALL MOUNT STRIP LED LIGHT FIXTURE COMBONATION BATH LIGHT & EXHAUST FAN FIXTURE CEILING RECESSED LIGHT FIXTURE WALL SWITCH (3-WAY) WALL SWITCH (DIMMER) LIGHTING LEGEND S CEILING MOUNT SMOKE DETECTOR WALL SWITCH d TV TV7' - 0 1/4"7' - 0 1/4"10" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0"[No Slope] [No Slope] 7' - 0 1/4" [No Slope] NOTE: ALL ELECTRICAL FIXTURES TO BE SELECTED BY HOMEOWNER 50" ABOVE FINISH FLOOR 50" ABOVE FINISH FLOOR POWER LEGEND TV CABLE / CATVTV DUPLEX OUTLET 1 A-03 MASTER BEDROOM MASTER BATH BATH BEDROOM BEDROOM HALL / OFFICE A-02 2 RAILING TO MATCH EXISTING RAILINGS WALK-IN CLOSET CLOSET CLOSET NEW PAINTED WOOD FINISH TREADS & RISERS ON EXISTING STAIR NEW FINISH FLOORING IN HALL; TO BE SELECTED BY HOMEOWNER 3 1/2" X 3 1/2" PSL POST 3 1/2" X 3 1/2" PSL POST EQ 10' - 8 3/8" V.I.F.EQ 3 1/2" X 3 1/2" PSL POST 3 1/2" X 3 1/2" PSL POST A-02 4 A-02 4 WRAP POST IN 1/2" GYPSUM WALL BOARD, WOOD TRIM TO MATCH EXISTING WALLS, & PAINT EXISTING DUCT SHAFT STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:16 AMA-01 LEVEL 2 & 3 FLOOR PLANS & REFLECTED FLOOR PLANS SHOWING POWER & LIGHTING LAYOUTS Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 1/4" = 1'-0"1 LEVEL 3 FLOOR PLAN 0'2'4'8'16' 1/4" = 1'-0"3 LEVEL 3 (ATTIC) REFLECTED CIELING PLAN - LIGHTING LAYOUT DIAGRAM 1/4" = 1'-0"4 LEVEL 3 (ATTIC) REFLECTED CIELING PLAN - POWER LAYOUT DIAGRAM 1/4" = 1'-0"2 LEVEL 2 FLOOR PLAN MARK DATE DESCRIPTION UP DN EXISTING 2X10 FLOOR JOISTS AT 16" O.C.; VERIFY FRAMING IN FIELD PRIOR TO START OF ALL & ANY WORK, TYP.9' - 2 5/8"(3) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL; [(4) 1 3/4" X 7.25" 2.0E MICROLLAM® LVL ONLY IF EXISTING FLOOR FRAMING IS 2X8 CONSTRUCTION, V.I.F.]25' - 11 1/4"36' - 0 7/8" 12' - 7 1/8"10' - 10 3/4"12' - 7"12' - 11 5/8"12' - 11 5/8"EXISTING 2X4 WOOD STUD WALLS BELOW 3 1/2" X 3 1/2" PSL POSTS UP TO RAFTER BEAM (3) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL; [(4) 1 3/4" X 7.25" 2.0E MICROLLAM® LVL ONLY IF EXISTING FLOOR FRAMING IS 2X8 CONSTRUCTION, V.I.F.]3' - 0"A-02 4 A-02 4 A-05 3 2X10 WOOD BLOCKING, TYP.15' - 4 7/8"13' - 0 3/8"3 1/2" X 3 1/2" PSL POST DOWN TO 1ST FLOOR CENTRAL BEAM, ADD 3.5" DIA LALLY COLLUMN ON 2'X2'X12" PAD FOOTING DIRECTLY BENEATH POST AT 1ST FLOOR BEAM 3 1/2" X 3 1/2" PSL POST DOWN TO 1ST FLOOR...PROVIDE BLOCKING BETWEEN JOISTS (AS REQUIRED) AN ADD 3.5" DIA LALLY COL ON 2'X2'X12" CONCRETE PAD FOOTING 2X10 COLLER TIES AT 16" O.C., TYP. EXISTING 2X10 RAFTERS @ 16" O.C., TYP. 2X8 RAFTERS AT 16" O.C.; RAFTER PITCH TO BE 5:12 2X10 WOOD RIDGE BOARD NOTE: PROVIDE SIMPSON STRONG-TIE HANGERS AT ALL CONNECTIONS, TYP. 35' - 0 7/8" EQ EQ CENTER ON EXISTING GABLE ROOF 24' - 10 1/4"(2) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL (2) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL 2X10 WOOD CEILING JOISTS AT 16" O.C. (1) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL HEADER EQ 10' - 11 3/8" V.I.F.EQ 12' - 5 5/8"12' - 4 5/8"(2) 2X10 WOOD RAFTER EXISTING GABLE ROOF OVERFRAMED ON EXISTING MAIN ROOF A-04 3 A-04 4 A-04 5 A-05 2 (2) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL RAFTER BEAM (2) 1 3/4" X 7 1/4" 2.0E MICROLLAM® LVL HEADER A-06 3 A-06 2 A-06 1 (2) 1 3/4" X 11.875" 2.0E MICROLLAM® LVL RIDGE BEAM OVER FRAME DORMER ROOF 36" HIGH WOOD RAILING TO MATCH EXISTING RAILING ON 2ND FLOOR HOMEOWNER TO SELECT FINISH TREAD AND RISER MATCH EXISTING HOUSE RAILING END POST EXISTING 2X6 DOUBLE TOP PLATE; VERIFY IN FIELD EXISTING 2X6 BOTTOM PLATE 2X6 WOOD STUD AT 16" O.C. VERIFY LOCATION IN FIELD 3 1/2" X 3 1/2" PSL WOOD POST; EXTEND DOWN TO FOUNDATION WALL, TYP. LEVEL 2 TRIPLE LVL RAFTER ABOVE EXISTING 2X12 RIM JOIST; VERIFY IN FIELD EXISTING 2X6 DOUBLE TOP PLATE; VERIFY IN FIELD EXISTING RAFTER TO REMAIN LEVEL 3 (ATTIC) 1 A-03 EXISTING MAIN CARRYING FLUSH BEAM; VERIFY LOCATION, SIZE, & TYPE IN FIELD PRIOR TO START OF ALL & ANY WORK 3 1/2" X 3 1/2" PSL POST; ADD LALLY COLUMN & FOOTING IN BASEMENT BELOW 3 1/2" X 3 1/2" PSL POST; ADD LALLY COLUMN & FOOTING IN BASEMENT BELOW LIVING ROOM DINING ROOM KITCHEN FAMILY ROOM PANTRY BATHROOM FOYER EXISTING DUCT SHAFT STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:17 AMA-02 LEVEL 1 FLOOR PLAN, FRAMING LAYOUTS DIAGRAMS & INTERIOR ELEVATION Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 1/4" = 1'-0"1 LEVEL 3 (ATTIC) FLOOR FRAMING PLAN DIAGRAM (DRAWING MUST BE PRINTED IN COLOR) 1/4" = 1'-0"3 ROOF FRAMING PLAN DIAGRAM (DRAWING MUST BE PRINTED IN COLOR) 1/2" = 1'-0"2 ELEVATION OF ATTIC STAIR 1" = 1'-0"4 TYPICAL EXTERIOR WALL FRAMING ELEVATION AT WOOD POST 1/4" = 1'-0"5 LEVEL 1 MARK DATE DESCRIPTION 0'2'4'8'16' LEVEL 2 14' -7 3/4" TOP OF ATTIC FLOOR SHEATHING 23' -6" KNEE WALL 27' -6 3/4" ATTIC FINISH FLOOR 23' -6 3/4"4 3/4"FINISH CEILING 30' -7" TOP OF WALL PLATE 30' -8"7' - 0 1/4"7' - 2"4' - 0"5" / 1'-0"5 " / 1 '-0 " EXISTING BEDROOM EXISTING BEDROOMEXISTING BATHROOM EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN, TYP. VERIFY IN FIELD; NEW DORMER RIDGE TO BE LOWER THAN EXISTING RIDGE 8' - 10 1/4"A-05 1NEW DORMER ROOF A-05 4 A-05 2 1 A-03 ROOF OVERHANG DETAIL TO MATCH EXISTING HOUSE 5" / 1'-0"5" / 1'-0" GABLE DORMEREXISTING ROOF TO REMAIN, TYP.10" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0"10" / 1'-0" 10" / 1'-0" 10" / 1'-0" 10" / 1'-0" STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:18 AMA-03 ROOF PLAN & BUILDING SECTION Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 1/2" = 1'-0"1 BUILDING SECTION 1/4" = 1'-0"2 ROOF PLAN MARK DATE DESCRIPTION 2X4 WOOD FRAMING AT 16" O.C. 1/2" GYPSUM WALL BOARD, PAINTED 2X6 WOOD BOTTOM PLATE WOOD BASE BOLDING; PAINTED; MATCH EXISTING HOUSE FINISH FLOORING; TO BE SELECTED BY OWNER ACCOUSTICAL SEALANT EXISTING FLOORING ASSEMBLY TO REMAIN FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) 1/2" GYPSUM WALL BOARD, PAINTED IGNITION BARRIER 1X3 WOOD FURRING AT 16" O.C. EXISTING 2X10 WOOD RAFTER 2X4 WOOD FRAMING AT 16" O.C. 1/2" GYPSUM WALL BOARD, PAINTED 2X6 WOOD TOP PLATE EXISTING ROOFING & WOOD ROOF SHEATHING TO REMAIN '-0" FINISH FROM FINISH FLOORFINISH KNEE WALLEXISTING 2X WOOD RIDGE BOARD TO REMAIN 10 12 EXISTING ROOFING AND ROOF SHEATHING TO REMAIN FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) EXISTING 2X10 WOOD RAFTERS TO REMAIN SPRAY APPLIED IGNITION BARRIER (2) 1 3/4" X 11.875" 2.0E MICROLLAM® LVL RIDGE BEAM 10 12 EXISTING ROOFING AND ROOF SHEATHING TO REMAIN SIMPSON STRONG-TIE DOUBLE-SHEAR FACE-MOUNT HANGER (HGUS410) FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) EXISTING 2X10 WOOD RAFTERS TO REMAIN SPRAY APPLIED IGNITION BARRIER SIMPSON STRONG-TIE FACE-MOUNT RAFTER HANGER AT ALL 2X10 WOOD RAFTERS (LRU210Z) (2) 1 3/4" X 11.875" 2.0E MICROLLAM® LVL RIDGE BEAM 10 12 EXISTING ROOFING AND ROOF SHEATHING TO REMAIN FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) EXISTING 2X10 WOOD RAFTERS TO REMAIN SPRAY APPLIED IGNITION BARRIER 3 1/2" X 3 1/2" PSL POST 2X6 WOOD BOTTOM PLATE NOTE: WALL & FLOORING FINISHES NOT SHOWN FOR CLEARITY EXISTING 2X10 FLOORING ASSEMBLY TO REMAIN, V.I.F. (3) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL FLOR BEAM; [(4) 1 3/4" X 7.25" 2.0E MICROLLAM® LVL ONLY IF EXISTING FLOOR FRAMING IS 2X8 CONSTRUCTION, V.I.F.] STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:19 AMA-04 TYPICAL DETAILS Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 3" = 1'-0"1 TYPICAL DETAIL AT BOTTOM OF KNEE WALL 3" = 1'-0"2 TYPICAL DETAIL AT TOP OF KNEE WALL 3" = 1'-0"3 TYPICAL DETAIL AT EXISTING RIDGE BOARD 3" = 1'-0"4 TYPICAL DETAIL AT RIDGE BEAM (HANGER) 3" = 1'-0"5 TYPICAL DETAIL AT RIDGE BEAM (RAFTER) 3" = 1'-0"6 TYPICAL DETAIL AT ATTIC FLOOR BEAM MARK DATE DESCRIPTION4 FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) 1/2" GYPSUM WALL BOARD -PAINTED 2X6 WOOD FRAMING; 2" CLOSED CELL SPRAY FOAM (R-13); FILL REMAINDER OF WALL CAVITY WITH R-15 FIBERGLASS BATT INSULATION; TYPICAL FOR ALL EXTERIOR 2X6 WOOD FRAMED WALLS (BOTH EXISTING & NEW) 1X3 WOOD FURRING AT 16" O.C. 1/2" GYPSUM CEILING BOARD; PAINTED 1/2" ZIP-WALL SHEATHING; WIPE ALL JOINTS, TAPE ALL JOINTS, & ROLL ALL JOINTS (TAPE LAID UP SHINGLE FASHION) MATCH EXSTING HOUSE EAVE DETAIL; VINYL TRIM (VERIFY IN FIELD) 2" POLYISO RIGID INSULATION R-13 (FRICTION FIT) 5 12 H8 SIMPSON STRONG-TIE HURRICANE CLIP @ EACH RAFTER, (TYP.) WHITE ALUMINUM GUTTER WHITE ALUMINUM DRIP EDGE 5/8" Z-WALL ROOF SHEATHING; WIPE ALL JOINTS, TAPE ALL JOINTS, & ROLL ALL JOINTS (TAPE LAID UP SHINGLE FASHION) SPRAY APPLIED IGNITION BARRIER ICE & WATER SHIELD; UP 3'-0" FROM ROOF EDGE 30LB FELT PAPER 2X10 WOOD CEILING JOISTS AT 16" O.C. 2X8 WOOD RAFTERS AT 16" O.C. MATCH EXSTING HOUSE SIDING; VINYL TRIM (VERIFY IN FIELD) (2) 1 3/4" X 9 1/4" MICROLAM LVL SELF ADHERED MEMBRANE TAPE WHITE ALUMINUM STEP FLASHING ROOFING SHINGLES 30LB FELT PAPER ROOF UNDERLAYMENT 30LB FELT PAPER UP SIDE WALL 1/2" GYPSUM WALL BOARD -PAINTED 2X6 WOOD FRAMING; 2" CLOSED CELL SPRAY FOAM (R-13); FILL REMAINDER OF WALL CAVITY WITH R-15 FIBERGLASS BATT INSULATION TERMINATE DOWNSPOUT INTO EXISTING GUTTER FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) SPRAY APPLIED IGNITION BARRIER MATCH EXSTING HOUSE SIDING; VINYL TRIM (VERIFY IN FIELD) MATCH EXSTING HOUSE SIDING; VINYL TRIM (VERIFY IN FIELD) SECURE EXISTING RAFTER EAVES TO EXISTING FLOOR JOISTS; RETAIN IN PLACE, TYP. EXISTING FLOOR ASSEMBLY TO REMAIN EXISTING WALL ASSEMBLY TO REMAIN TILE FLOORING; TO BE SELECTED BY OWNER 1/2" GYPSUM WALL BOARD -PAINTED 2X6 WOOD FRAMING; 2" CLOSED CELL SPRAY FOAM (R-13); FILL REMAINDER OF WALL CAVITY WITH R-15 FIBERGLASS BATT INSULATION 1/2" Z-WALL SHEATHING; WIPE ALL JOINTS, TAPE ALL JOINTS, & ROLL ALL JOINTS (TAPE LAID UP SHINGLE FASHION) PLYWOOD FLOOR SHEATHING WOOD BASE TO MATCH EXISTING HOUSE 2X10 WOOD RIDGE BOARD 5/8" ZIP-WALL ROOF SHEATHING; WIPE ALL JOINTS, TAPE ALL JOINTS, & ROLL ALL JOINTS (TAPE LAID UP SHINGLE FASHION) SIMPSON STRONG-TIE FACE-MOUNT RAFTER HANGER AT ALL 2X8 WOOD RAFTERS (LRU28Z) FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) 2X8 WOOD RAFTERS AT 16" O.C. 5 12 ASPHALT SHINGLE RIDGE CAP 30 YEAR ASPHALT ROOFING SHINGLE SYSTEM; MATCH EXISTING HOUSE STYLE & COLOR5" MIN.TOP OF EXISTING HOUSE'S MAIN ROOF RIDGE BEYOND ENSURE NEW DORMER ROOF RIDGE IS 5" MIN. BELOW EXISTING HOUSE'S ROOF RIDGE 30LB ROOFING UNDERLAYMENT FELT PAPER SPRAY APPLIED IGNITION BARRIER STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:20 AMA-05 TYPICAL DETAILS Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 3" = 1'-0"1 TYPICAL DETAIL AT DORMER EAVE 3" = 1'-0"2 TYPICAL DETAIL AT DORMER CHEEK WALL 3" = 1'-0"3 TYPICAL DETAIL AT DORMER GABLE WALL 3" = 1'-0"4 TYPICAL DETAIL AT DORMER RIDGE BOARD MARK DATE DESCRIPTION (1) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL HEADER EXISTING ROOFING AND ROOF SHEATHING TO REMAIN SIMPSON STRONG-TIE DOUBLE- SHEAR FACE-MOUNT JOIST HANGERS AT EACH 2X10 WOOD RAFTER (LUS210) FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) 1/2" GYPSUM WALL BOARD, PAINTED IGNITION BARRIER 1X3 WOOD FURRING AT 16" O.C. EXISTING 2X10 WOOD RAFTER 2X10 WOOD CEILING JOISTS AT 16" O.C. 10 12 2X4 WOOD FRAMING AT 16" O.C. 1/2" GYPSUM WALL BOARD, PAINTED 2X4 WOOD TOP PLATE FILL CAVITY WITH SOUND ATTENUATION BATT INSULATION 2X10 WOOD CEILING JOISTS AT 16" O.C. EXISTING OVERFRAMED GABLE ROOF ABOVE (1) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL HEADER EXISTING ROOFING AND ROOF SHEATHING TO REMAIN SIMPSON STRONG-TIE FACE- MOUNT HANGERS (HU7) FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) 1/2" GYPSUM WALL BOARD, PAINTED IGNITION BARRIER 1X3 WOOD FURRING AT 16" O.C. (3) 1 3/4" X 9 1/4" 2.0E MICROLLAM® LVL RAFTER 10 12 2X4 WOOD FRAMING AT 16" O.C. 1/2" GYPSUM WALL BOARD, PAINTED 2X4 WOOD TOP PLATE FILL CAVITY WITH SOUND ATTENUATION BATT INSULATION 2X10 WOOD CEILING JOISTS AT 16" O.C. EXISTING OVERFRAMED GABLE ROOF ABOVE FILL RAFTER CAVITIES WITH R-49 CLOSED CELL SPRAY FOAM (FOAM LOK 2000-4G) EXISTING ROOFING & WOOD ROOF SHEATHING TO REMAIN (2) 1 3/4" X 7 1/4" 2.0E MICROLLAM® LVL RIDGE BEAM SIMPSON STRONG-TIE DOUBLE-SHEAR FACE-MOUNT HANGER (HGUS48) EXISTING 2X10 WOOD RAFTER 1X3 WOOD FURRING AT 16" O.C. 2X4 WOOD FRAMING AT 16" O.C. 1/2" GYPSUM WALL BOARD, PAINTED 2X4 WOOD TOP PLATE FILL CAVITY WITH FIBERGLASS BATT INSULATION WOOD RAFTER BEYOND 2X10 WOOD COLLAR TIE / CEILING JOIST AT 16" O.C. OUTLINE OF LVL RAFTER BEAM IN WALL BEYOND SPRAY APPLIED IGNITION BARRIER SIMPSON STRONG-TIE DOUBLE-SHEAR FACE-MOUNT HANGER (LUS48) STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:20 AMA-06 TYPICAL DETAILS Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 3" = 1'-0"1 TYPICAL DETAIL AT HEADER (AT RAFTER) 3" = 1'-0"2 TYPICAL DETAIL AT HEADER (AT KING RAFTER) 3" = 1'-0"3 TYPICAL DETAIL AT DORMER HEADER MARK DATE DESCRIPTION GABLE OVERHANG & EAVE DETAILS TO MATCH EXISTING HOUSE PROVIDE GUTTERS & DOWNSPOUT TO MATCH EXISTING HOUSE (BOTH SIDES OF ROOF) MATCH EXISTING BATHROOM WINDOW SIZE, COLOR, & STYLE; WINDOWS TO ALIGN SIDING TO MATCH EXISTING HOUSE GABLE OVERHANG & EAVE DETAILS TO MATCH EXISTING HOUSE PROVIDE GUTTERS & DOWNSPOUT TO MATCH EXISTING HOUSE MATCH EXISTING BATHROOM WINDOW SIZE, COLOR, & STYLE; WINDOWS TO ALIGN SIDING TO MATCH EXISTING HOUSE STAMP SHEET TITLE DATE: PERMIT SETINTENDED TO BE PRINTED ON 24" X 36" PAPER SIZE11/29/2019 9:05:22 AMA-07 EXTERIOR PERSPECTIVES Attic Renovation 1 Amanda Way, Salem, MA 01970 11/29/2019 1 PERSPECTIVE 1 - PROPOSED 2 PERSPECTIVE 2 - PROPOSED 3 PERSPECTIVE 1 - EXISTING 4 PERSPECTIVE 2 - EXISTING MARK DATE DESCRIPTION