BUILDING 3 - FP (002)Job: PROPOSED MULTI -UNIT RESIDENTIAL BUILDING Address: 9 SOUTH MASON ST - BUILDING 3 City: SALEM Contract #: 380-003 Contractor: VILLAGE FIRE PROTECTION Address: 86 MILFORD ST City: MILFORD State: MA Date: Designer: State: NH Zip/Postal Code: 01970 4/2/2018 JFP SOLUTIONS, INC. Zip/Postal Code: 03055 Phone: (603) 672-6267 Fax: Email: Approving Authority: SALEM FD Design Defaults Default Sprig Size: Default Sprig Material: Default Sprig Elevation: 1 CPVC 0 Standards: NFPA 13 Default Drop Size: 1 Default Drop Material: CPVC Default Drop Elevation: 0 0 0 Seal the clearance space around the sprinkler barrel to avoid leakage of sir into the protected area and consequent formation of condensate around the sprinkler Frame, which could Inhibit oper- ation or cause premature operation. Refer to Figure 10 below. If humidity and temperature differential causes condensotlon on the exposed dry sprinkler barrel. consider wrapping the exposed barrel with insulotlon, foam Insulating tape, or equivolent. Install 1 inch NPT threaded end of dry sldewalt sprinkler Into the 1 Inch NPT outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast Iron threaded tee fitting per ANSI 16.4 (Class 125> only. MI8i8n . .a11 opening diameter. 1-3/4' (44,5 rive) Maximum .all opening diameter; 2-V4' (57 mn). Ambient Tenper Exposed Oarrel Ambient Temperature IeTl4'ClSeil10Y�67FlK'C of Protected Area4i at the Discharge End °F Uw Sa#YAar Exposed Namur. Barrel length... race of the Tee t0 the Omer Surface of thw 1Jn1Y In (n1) In <n1J IM1 40'F (4'C) 0 0 „In 0 30'F (-1'C) 0 0 4 201- (-7'C> 4 (100) 0 0 I01' (-12'C) 9 (203) I (25.4) 0 0-F (-le'C) 12 <305) 3 (76) 0 -10'T (-23'C) 14 (356) 4 (102) 1 (254) -20'F (-29'C) 14 (356) 6 (152) 3 (76) -30'F (-34'C) 16 <406) 0 (203) 4 (102) -40'F (-40'C) le (457) 8 <203) 4 u02) -50'F (-46'C) 20 (508/ 10 (2541 6 (152) -60'F (-51'0 20 (508110 {2541 6 C152) 13/16' CeNing (20.6 err) (Protected Area) Outer Surface of the Mall 3-1/16' (77.8 mm) I-1/2' (38,1 nn) diameter, Sleeve finish matches escutcheon finish Up to 2' (50.8 rn) of adjustment is avanable. 3-1/4' (82.6 mn) Minlmur 5-1/4' (133.4 mm) Maximum NOTE. To locate the Deflector at deflector at the Madre" Distance maxilUM distance from From WI the +(all, with no adjustment available, order the standard dry horizontal side - wall sprinkler 1' longer than the 'A' dimension. IIIWII j�ilii i i.11Fh De nectar at m Pereften Distance From Wail NpTE' To locate the deflector at the nillmun distance fro, - the wail, with no adjustment available. order 'the standard dry horizontal side - wall sprinkler 1' shorter than the 'A' dimension *May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. waThe protected area refers to the area below the ceiling, The ambient temperature Is the temperature at the discharge end of the sprinkler. For protected area temperatures thot occur bet.een the values listed, use the next cooler temperature. 9R**The minimum required barrel length Is not the same as the 'A' dimension. Refer to Figures 3, 5, and 7 for the 'A' dimension. Exposed minimum barrel lengths ore inclusive up to 30 mph wind velocities. 0 O 0 0 Tee with same outlet size as sprinkler thread size. See "Important Installation Information", later in this document 0 0 0 o-� 10-0 ■ YS BASEMENT 4" CONCRETE SLAB 10-0 1 o SL+ 9AB6" 1 T.O.0 i 8a 1 P ) 024 1 STEP ['OWN >1 10-0 T.O.C. + 9'-8 a 1- ■ 002 T.O.C. + ICE-Io ' �n - 3 022 10-6 i 548 2-0, 6-38,2 3 2" Min. Dia. Hole in Wall Recessed 0 3 3 5 (EXIST) 5 0 0 0 0 0 OQ 0 0 UP 2 KITCHEN BATH 0 11 2 4-3,2 4-1'2 CL LIVING/DINING 0 0 0 0 8-1', UP 3-7 8-0 PROVIDE 4" STORZ CONNECTION (TYPE AND FINAL LOCATION TO BE VERIFIED WITH SALEM FIRE DEPARTMENT PRIOR TO INSTALLATION) s FIRE PROTECTION NOTES/NARRATIVE: UP DRY UP 3 PROVIDE BULK RESIDENTIAL 2" CPVC MAIN RUNNING THROUGH SOFFIT ON GROUND LEVEL (FIELD -VERIFY LOCATION) KITCHEN L VING/DINING UP 4" BACKFLOW PREVENTER, 3" DRY VALVE, 2" STRAIGHT -PIPE RESIDENTIAL RISER AND 4" FDC FEED (SEE DETAIL, THIS SHEET) • RY UP 0 DRY LIVING/DI NG TYPICAL 2" CPVC MAIN UP TO SECOND FLOOR (TYPICAL) 4 0 0 2 0 9- 10-0 T.O.EXISTING SLAB + 5-8' VLF. De ■ 2 X 6 DEMISING WALLS D/ ON G" CONC. CURB YS ■ • 10-0 O 0 U DRY UP LL • • THE PURPOSE OF THIS FIRE PROTECTION DRAWING AND THE ASSOCIATED HYDRAULIC CALCULATIONS IS TO INDICATE THE PROPOSED AUTOMATIC SPRINKLER SYSTEM TO BE INSTALLED WITHIN BUILDING 3, LOCATED AT 9 SOUTH MASON STREET IN SALEM, MASSACHUSETTS. THE OWNER OF THIS PROPERTY PLANS TO RENOVATE AND ADD ADDITIONS TO THE TWO EXISTING BUILDINGS (BUILDING 1 AND 3) AT THIS TIME. EACH BUILDING WILL BE RENOVATED AS INDICATED ON THE ARCHITECTURAL DRAWINGS. EACH BUILDING WILL CONTAIN RESIDENTIAL DWELLING UNITS AND IS CONSTRUCTED OF COMBUSTIBLE MATERIALS, REQUIRING THE SPRINKLER SYSTEM TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) AND THE 9TH EDITION OF THE MASSACHUSETTS STATE BUILDING CODE. BUILDING 3 CONSISTS OF AN EXISTING 2-UNIT BUILDING WHICH WILL HAVE A 5-UNIT ADDITION CONSTRUCTED AS INDICATED. EACH UNIT WILL CONSIST OF A GROUND LEVEL, SECOND LEVEL AND THIRD LEVEL. THE BUILDING WILL HAVE AN UNHEATED CRAWLSPACE BENEATH IT WHICH WILL BE UNHEATED AND WILL NOT BE USED FOR STORAGE OR MECHANICAL EQUIPMENT. THE CRAWLSPACE WILL BE PROTECTED BY A DRY -PIPE SPRINKLER SYSTEM CONSISTING OF GALVANIZED PIPING AND CORROSION -RESISTANT SPRINKLER HEADS. THE DRY SYSTEM WILL BE PITCHED TO LOW POINT DRAINS WHICH SHALL BE PROPERLY DRAINED IN ACCORDANCE WITH NFPA 25. THE RESIDENTIAL AREAS WILL BE FED FROM A 2" SPRINKLER ZONE USING CPVC SPRINKLER PIPING AND RESIDENTIAL SPRINKLER HEADS AS INDICATED. THIS RESIDENTIAL SPRINKLER SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) FOR A RESIDENTIAL BUILDING UP TO 4 STORIES IN HEIGHT, EXCEEDING 12,000 SF IN AGGREGATE FLOOR AREA. THE TOP STORY OF THIS BUILDING DOES NOT EXCEED 30-FT ABOVE FIRE DEPARTMENT VEHICULAR ACCESS AND THEREFORE NO STANDPIPE SYSTEM IS REQUIRED. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13 (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE AND THE SALEM FIRE DEPARTMENT REQUIREMENTS. THIS SYSTEM WILL BE SUPPLIED BY A NEW 6" FIRE SERVICE, TAPPED OFF THE EXISTING WATER MAIN ON SOUTH MASON STREET. THE 6" SERVICE SHALL BE DESIGNED, INSTALLED, FLUSHED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 24 BY A LICENSED UNDERGROUND CONTRACTOR AND WILL ENTER THE HEATED UTILITY ROOM AS INDICATED ON THIS DRAWING (DESIGNED BY OTHERS) THE SPRINKLER CONTRACTOR WILL PROVIDE A 6x4" VIC-FLANGE, 4" BACKFLOW PREVENTER AND 4" MANIFOLD AS INDICATED ON THIS DRAWING. A 2" STRAIGHT -PIPE RISER WILL SUPPLY THE RESIDENTIAL SPRINKLER PROTECTION AND THE 4" DRY VALVE WILL DROP TO THE CRAWLSPACE BELOW (SEE DETAIL THIS SHEET) THE SYSTEM HAS BEEN HYDRAULICALLY CALCULATED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13, INCLUDING THE FOUR HYDRAULICALLY MOST DEMANDING HEADS IN A SINGLE COMPARTMENT BASED ON THE REQUIREMENTS OF THE SPECIFIC SPRINKLER HEAD AND THE SPACING USED IN THIS DESIGN (16'x16' REQUIRING A MINIMUM OF 16 GPM @ 7.6 PSI OR THE MINIMUM PRESSURE REQUIRED TO MEET 0.10 GPM/SF OVER THE ACTUAL COVERAGE AREA). THE CRAWLSPACE DRY -SYSTEM HAS BEEN DESIGNED AS A LIGHT HAZARD OCCUPANCY PER NFPA 13 REQUIREMENTS FOR AREAS OUTSIDE LIVING SPACES. REMOTE AREAS, DENSITIES AND HOSE STREAM ALLOWANCES ARE INDICATED ON THIS DRAWING. SYSTEM DEMANDS HAVE BEEN COMPARED TO HYDRANT FLOW DATA PERFORMED ON THE WATER MAIN IN SOUTH MASON STREET. COPIES OF THE CALCULATIONS HAVE BEEN SUBMITTED WITH THESE DRAWINGS TO THE SALEM FIRE DEPARTMENT AND BUILDING DEPARTMENT FOR REVIEW. INSTALLATION NOTES: 2- UP 2 4-3,' F KITCHEN 2-9/16- <65 rrn) Maximum Design Area 2 Dry System CRAWL -SPACE Demand Calculations using Hazen -Williams Method Occupancy Classification: LIGHT HAZARD Design Area Density: 0.1 Additional Outside Hose: 100 Design Area Size: 1960 Notes: THIS CALCULATION INCLUDES THE HMD 1950 SF OF THE DRY SYSTEM PROTECTING THE CRAWL -SPACE BELOW THE BUILDING (NON -STORAGE) CRAWLSPACE LEVEL SPRINKLER LAYOUT SCALE: %" = 0 UP c0 c0 2 L}Vu.ir-/pu.ul.1C 2-0 DRY 0Q 0 0 I KITCHEN 4 2-0 0 2 6-Ps BATH 0- BATH 5 2-3 C 5 4- LIVING/DINING CLO ,ET2-4 C 2-9 KITCHEN 2 • 3 JP 2 UP 00 oa 20 4-11,z LIVING/DINING 7 U 21 -6 2-0 DRY DRY PROVIDE DRY-SIDEWALL HEADS UNDER COVERED PORCHES (TYPICAL) NOTE: SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING APPROPRIATE LENGTH OF ALL DRY-SIDEWALL HEADS AND FOLLOWING MANUFACTURER'S REQUIREMENTS FOR INSTALLATION TO AVOID FREEZE -UPS. ALL WORK SHALL BE PERFORMED BY A MASSACHUSETTS LICENSED SPRINKLER CONTRACTOR. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13 (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE (9TH EDITION) AND THE SALEM FIRE DEPARTMENT. THE ARCHITECTURAL BACKGROUND OF BUILDING MAY DIFFER SLIGHTLY FROM ACTUAL LAYOUT. DRAWINGS ARE NOT INTENDED TO SHOW ALL OFFSETS AND PIPING ELEVATION CHANGES. CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS PRIOR TO FABRICATION. CONTRACTOR SHALL HYDROSTATICALLY TEST ALL SPRINKLER PIPING AT 200 PSI FOR 2 HOURS AND IS RESPONSIBLE FOR THE COMPLETION OF ALL ABOVE GROUND TEST CERTIFICATES, SUPPLIED TO THE OWNER. ALL PIPING INSTALLED ON THE UPPER FLOORS SHALL BE UL LISTED CPVC SPRINKLER PIPING. ALL PIPING INSTALLED WITHIN THE CRAWLSPACE LEVEL SHALL BE EXPOSED GALVANIZED BLACK STEEL. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) AND ALL MANUFACTURERS INSTALLATION RECOMMENDATIONS. ALL DRY SYSTEM PIPING SHALL BE PITCHED TO DRAIN WITH LOW -POINT AUXILIARY DRAINS AT SECTIONS OF PIPING SUBJECT TO WATER TRAPPING. SPRINKLER CONTRACTOR SHALL PROVIDE PROTECTIVE PLATES WHERE CPVC PIPING IS RUN THROUGH STUDS TO PREVENT PUNCTURING OF THE SPRINKLER PIPING DURING DRYWALL INSTALLATION AS REQUIRED BY NFPA STANDARDS. NO COMBUSTIBLE INTERSTITIAL SPACES ARE ANTICIPATED WITHIN THIS BUILDING. ANY SUCH SPACES CREATED DURING CONSTRUCTION SHALL BE PROTECTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) OR COMPLETELY FILLED WITH NON-COMBUSTIBLE INSULATION. ALL SPRINKLER HEADS SHALL BE RESIDENTIAL PENDENT (RESIDENTIAL AREAS) AND QUICK -RESPONSE UPRIGHTS (BASEMENT AREA). ALL HEADS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND THE REQUIREMENTS OF NFPA 13 (2013 EDITION). THE BUILDING OWNER IS RESPONSIBLE FOR MAINTAINING THIS SPRINKLER SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25, INCLUDING THE PROVISION OF HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR ANY DAMAGES CAUSED BY FREEZE UPS. GROUND LEVEL SPRINKLER LAYOUT SCALE: %a' = 1'-0" PROVIDE REMOTE INSPECTOR'S TEST CONNECTION ON DRY -SYSTEM (FIELD -LOCATE) 1" THREADED NIPPLE 1" GLOBE VALVE 1" X 0-4" NIPPLE 2" X 1" RED. COUP. 2" X 1'-0" THREADED NIPPLE 2" X 1" RED. COUP.` 1" X 0-4" NIPPLE 1" GLOBE VALVE 1" PLUG 7 "" DRY SYSTEM AUXILARY DRAIN (DRUM DRIP) Design Area 1 Wet System TOP FLOOR UNIT Demand Calculations using Hazen -Williams Method Occupancy Classification: RES 13 Design Area Density: 0.1 Additional Outside Hose: 100 Design Area Size: 387 Notes: THIS CALCULATION INCLUDES THE AREA PROTECTED BY THE 4 HMD RESIDENTIAL HEADS ON THE TOP FLOOR PROVIDE RESIDENTIAL SIDEWALL SPRINKLERS (VIKING MODEL VK460, K=5.8) REQUIRING A MINIMUM OF 31 GPM @ 28.6 PSI FOR A MAXIMUM SPACING OF 16' x 22'. (LOCATE HEADS A MAXIMUM OF 6" DOWN FROM CEILING) 4" DRY SYSTEM FEED TO CRAWLSPACE (PROVIDE LOW -POINT DRAIN AT BASE OF DROP. OWNER RESPONSIBLE FOR KEEPING SYSTEM PROPERLY DRAINED) 4" DRY VALVE WITH TRIM AND AIR COMPRESSOR 4" AMES C200 BACKFLOW PREVENTER WITH MONITORED BFVs OR EQUAL) jILC Mfg dam -- NMI CLi G"x4" VIC-FLANGE G" SERVICE (INSTALLED, FLUSHED, TESTED $ CUT TO HEIGHT, BY OTHERS) 2" STRAIGHT -PIPE RISER TO RESIDENTIAL SPRI NKLERS 4" GROOVED CHECK WITH BALL DRIP 4" GROOVED TEE WITH CAP (FOR FORWARD FLOW TESTING OF BACKFLOW) RISER DIAGRAM AND MANIFOLD DETAIL SCALE: NOT TO SCALE ELECTRIC BELL WITH BACKER -BOX (WIRED BY OTHERS) BY GRO- OVE) THROUGH WALL 4" STORZ CONNECTION (MOUNT PER FD BY THD) - THROUGH WALL WITH 45° EL AND WALL PLATE FREEZE PRETECTICIN THE BUILDING OWNER IS RESPONSIBLE FOR PROVIDING HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. ANY AREAS THAT RAISE CONCERN WITH REGARD TO FREEZING POTENTIAL SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION, IN WRITING, PRIOR TO INSTALLATION. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR DAMAGES CAUSED BY FREEZE -UPS OF THE SPRINKLER SYSTEM. TYPICAL 2" CPVC MAIN UP FROM BELOW (TYPICAL) .262 SYSTEM ISOMETRIC SCALE: NOT TO SCALE MAX. HANGER SPACING PIPE NOMINAL PIPE SIZE (IN) SCH 7,10,40 N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 SCH 30 LIGHT N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A -60" MAX FOR 1 1/2" DIA. OR LARGER THEN EXTEND HERE DISTANCE BETWEEN I I NCR ON STARTER PIPES .--I OMIT SHALL NOT EXCEED 6' OR LESS, NO X-MAIN HGR ABOVE TABLE OMISSIONS ALLOWED IF GREATER THAN 48" MAX. FOR 1 1/4" DIA. IF GREATER THAN 60" FOR 1 1/2" DIA. OR LARGER WOOD JOIST CONSTRUCTION RESIDENTIAL CONCEALED SPRINKLER TYPICAL MAINTAIN NFPA 13 OBSTRUCTION CRITERIA (TYPICAL) CPVC MAIN LOCATED WITHIN HVAC SOFFIT FEEDING BRANCHLINES LOCATED WITHIN JOIST CHANNELS (TYPICAL) GYPSUM BOARD CEILING ON WOOD STRAPPING TYPICAL RESIDENTIAL PENDENT SPRINKLER INSTALLATION NOT TO SCALE Caution: Care should be token to avoid compressing the insulation. This reduces its R value. To prevent potential freeze -ups of the sprinkler piping, the insulation should be installed tight against the joists. INSULATION PROTECTING SPRINKLER PIPING ON UPPER FLOOR DETAIL NOT TO SCALE SECOND LEVEL SPRINKLER LAYOUT THIRD LEVEL SPRINKLER LAYOUT Source Information Date of Flow Test / Info : 3/6/2018 Location of flow test data : END OF BUFFUM ST. EXT. Source of flow test data : JFP SOLUTIONS Source Data Points Pressure I Flow 80.00 0.00 60.00 750.00 Pump Data Points Pressure I Flow PROVIDE QUICK -RESPONSE RESIDENTIAL PENDENT SPRINKLERS IN ALL LOCATIONS INDICATED (TYPICAL, K=5.8, MAXIMUM SPACING: 145(14' or 165(12' (DO NOT EXCEED 196 SF PER HEAD). MINIMUM PRESSURE FOR 0.05 DENSITY FOR 16'x16' SPACING IS 7.6 PSI PER HEAD MANUFACTURER (VIKING VK474, K=5.8). TYPICAL 1 Y." CPVC RISER UP FROM FLOOR BELOW (TYPICAL FOR ALL RISERS FEEDING MORE THAN 1 SPRINKLER HEAD) PROVIDE RESIDENTIAL SIDEWALL SPRINKLERS (VIKING MODEL VK460, K=5.8) REQUIRING A MINIMUM OF 26 GPM @ 20.1 PSI FOR A MAXIMUM SPACING OF 16' x 20'. (LOCATE HEADS A MAXIMUM OF 6" DOWN FROM CEILING) Design Area 3 Wet System TOP FLOOR UNIT Demand Calculations using Hazen -Williams Method Occupancy Classification: RES 13 Design Area Density: 0.1 Additional Outside Hose: 100 Design Area Size: 386 Notes: THIS CALCULATION INCLUDES THE AREA PROTECTED BY THE 4 HMD RESIDENTIAL HEADS ON THE TOP FLOOR Calculation results for Design Area 2 - CRAWL -SPACE This system as shown on VILLAGE FIRE PROTECTION company print no for PROPOSED MULTI -UNIT RESIDENTIAL BiatILONEUTH MASON ST - BUILDING 3 dated 4/2/2018 contract no 380-003 is designed to discharge at a rate of 0.1 gpm/fr (L/min/ml of floor area over a maximum area of 1960 fr when supplied with water at a rate of 426.1 qpm at 47.3 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: LIGHT HAZARD Number of heads flowing: 24 Commodity classification: System Type: Dry Maximum storage height: Maximum velocity: 16.38 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 426.1 gpm 0 gpm 0 CM 100 cpm 526.1 gpm Pressure Required at Source: 47.3 psi Pressure Available at Source: 69.6 psi Surplus Pressure at Source: 22.3 psi Calculation results for Design Area 1 - TOP FLOOR UNIT This system as shown on VILLAGE FIRE PROTECTION company print no for PROPOSED MULTI -UNIT RESIDENTIAL BilliLOINSJTH MASON ST - BUILDING 3 dated 4/2/2018 contract no 380-003 is designed to discharge at a rate of 0.1 gpm/fr (LJmin/m2) of floor area over a maximum area of 387 fr when supplied with water at a rate of 126.7 gpm at 66.6 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: RES 13 Number of heads flowing: 4 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 13.03 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 126.7 gpm 126.7 gpm 100 cpm Pressure Required at Source: 66.6 psi Pressure Available at Source: 77.8 psi Surplus Pressure at Source: 11.2 psi Calculation results for Design Area 3 - TOP FLOOR UNIT This system as shown on VILLAGE FIRE PROTECTION company print no dated 4/2/2018 for PROPOSED MULTI -UNIT RESIDENTIAL 131911.10901UTH MASON ST - BUILDING 3 contract no 380-003 is designed to discharge at a rate of 0.1 gpm/fr (L/min/m2) of tloor area over a maximum area of 386 fr when supplied with water at a rate of 107.7 qpm at 65.5 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: RES 13 Number of heads flowing: 4 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 11.21 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 0 gpm 100 gpm 207.7 gpm Pressure Required at Source: 65.5 psi Pressure Available at Source: 78.1 psi Surplus Pressure at Source: 12.6 psi DESIGNED BY: REVISIONS HEAD BLOCK 3F13 SOLUTIONS/ INC. FIRE PROTECTION CONSULTING SERVICES P.O. Box 1234 Lynnfield, Massachusetts 01940 Telephone: (781) 389-7999 DATE DESCRIPTION BY SYM CNT POSITION FINISH TEMP K NPT MFG. 121 RES PENDENT WHITE 155 5.80 1/2" REL. 14 7 DRY SIDEWALL WHITE 155 5.60 1/2" REL. CPVC SPRINKLER PIPING STEEL SPRINKLER PIPING - - DRY SYSTEM PIPING - - ILLA SPRINKLER CONTRACTOR E FIRE PR TECTI 86 MILFORD STREET ILFORD, NH 03055 (603; 672 6267 NEW AUTOMATIC SPRINKLER SYSTEM NG 3 S UTH AS SALEM, MASSACHUSE PROJECT ADDRESS STREET TS 03055 SPRINKLER SYSTEM PERMIT SET PERMIT NO CONTRACT NO. 380-003 APPROVAL SALEM FD DRAWN BY T. JENKINS SCALE DATE 4/2/2018 REVISED FP 1 of 1 JASON M.G. ▪ FIRE PROTECTION trt co PLOTTED