Loading...
400 Highland suite 13 FAPi� 1 f� 1 / i / I 1 /1 i�1 0 .1 e , STUDIO 13 STUDIO 16 ST. is ac ) I --- 1' V i i fl IIII 1 _ 1 1 1 1 T)1 t STUDIO 23 FIXTURE PLAN SCALE: 1/4" = STUDIO 15 STUDIO 17 STUDIO 19 STUDIO 24 FIRE EXTINGUISHER UIECH.MEZZ BREAK RM STUDIO 1 WOMEI STUDIO 8 STUDIO 4 STUDIO 7 STUDIO 5 pukt\ T7" 1 I on) 1+� /srz0 t_ 6' 6IL-L 0--T r PROJECT SUMMARY Proposed Use: Salon Owner's authorized Agent: Jansen Gehring Phone # 317-259-7000 Owned by a Private Owner Code enforcement: Salem Lead Design Professional Cortland Morgan Code 2015 International Building Code w/9th Edition MA. Amendments Gross project area - 4,630 SF Primary Occupancy - Business (salon) Secondary Occupancy - None Special Occupancy -None Mixed Occupancy -None Allowable Height (existing building shell approved by original building permit - tenant build -out does not alter height) Fire protection Requirements Existing 1 hour separation provided between adjacent vacant suite Roof system -Non Combustible Bearing walls -Non Combustible Structural Frame -Non Combustible Non bearing walls -Non Combustible Life Safety Requirements Emergency Lighting - yes Exit Signs - yes Fire alarm - yes Smoke detection System - no Panic Hardware- NO Sprinkler System - Yes (plans provided under separate permit) Exit requirements for occupancy of 52 people (1 per workstation + one client) Minimum Number of Exits (2 req'd- 2 provided (shown on plans) Allowable maximum travel distance 150 ft (table 1004.2.4)- maximum travel distance 90 ft Required distance between exit doors- 48ft' (half of space diagonal) provided 30ft front to back B occupancy 52 occupants Exit width required (44" minimum) - 60" provided. Structural Loads Approved by original building permit- tenant build -out does not alter building structural system. Plumbing Fixture requirements B occupancy (52 people) 1 male and 1 female water closet required - 1 Male and 2 female water closets provided +1 urinal 1 male lavatory and 1 female lavatory required - 1 male and 2 female lavatories provided. 1 Drinking Fountain required - 1 Hi-Lo drinking Fountain provided. Accessible Parking approved by original building permit- tenant build -out does not alter parking on site. Special approvals N/A Electrical Summary Reference sheets El .1 and El .2 for electrical tables. (prescriptive compliance) Mechanical Summary Reference sheet Mi .1 for mechanical information SPRINKLER SCOPE NOTES: 1. DESIGN & SUBMIT PERMITS TO MEET NFPA13 STANDARD (OR GREATER IF REQUIRED BY CITY). 2. DESIGN & SUBMIT SPRINKLER HEAD LAYOUT TO SUBMIT TO GC FOR APPROVAL. 3. TIE INTO EXISTING WET SPRINKLER SYSTEM & DEMO ANY EXISTING LINES THAT ARE NOT PART OF APPROVED PLANS. 4. INSTALL SPRINKLER HEADS & ESCUTCHEONS: A. NOT LOCATED IN THE CENTER OF STUDIO (DUE TO FUTURE LIGHTING B. HALLWAY COLOR: CHROME (ESCUTCHEONS) C. STUDIOS, RESTROOMS, BREAK ROOM COLOR: WHITE (ESCUTCHEONS) 5. FINISHED FLOORS, CABINETS, & FIXTURES MUST BE PROTECTED WHEN WORKING ABOVE. 6. SPRINKLER CONTRACTOR ULTIMATELY RESPONSIBLE FOR ANY DAMAGE CAUSED BY THEIR EQUIPMENT, MATERIALS, OR WORKERS. 7. VERIFY CO SENSOR REQUIREMENTS. hci APPROVED 3ub33et to... approval by any other authority having iuriediction. CITY of SALEM, MASS. Tr .PP..rrBUREAU BY L PLANS ARE APPROVED SOLELY FOR #O) iTIr'CATION OF TYPE AND LOCATION OF PtRl F-F f'-LION DEVICES ALL FIRE, FROTECTION DEVICES .n. CUSJECi TO F' 'r .TEST AND INSPECTION, FOR COMPLETE CCTV. Apt -yE ..'PE COD' FIXTURE PLAN & SCHEDULES CORTLAND MORGAN ARCHITECT 711 N. FIELDER RD. ARUNGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 CERTIFIED I I , ' BY: '1 � ► f R,;.`: 5 ;SI fR DRAWN BY: STAFF (105)/;Ara) uio a� po iH 0 TUDIOR IZ GEORGE AND ELIZABETH MORRIS OWNER BUS.: 781-267-1399 CEL.: 781-267-1396 BANYAN CONSTRUCTION GENERAL CONTRACTOR JANSEN GEHRING PH.: 1312 259 7000 PROJECT: SL-MA-302 HIGHLAND AVE RELEASE DATE 6/17/19 REVISIONS: DRAWING LIFE SAFETY SHEET LS1.1 NAME PLAN NO. GENERAL NOTES: STUDIO 13 B 34 A- 5" /////////l/ A- B-3 GFCI - A- GFCI STUDIO 14 .///////44//////////////////, STUDIO 16 STUDIO 18 STUDIO 20 45" C 21 A A- 45 GFCI g///////// /T///��/ C-25 STUDIO 21 C+ A- GFCI -. E C-25 / ////.////// Z/// ///////7/// 13 I o$ b A- GFCI C-2 STUDIO 22 A A- C-31 0 GFCI 0 C-31 STUDIO 12 A- GFCI B-30 B-30A ///////////////firm/m/-,,,, C cA 45 STUDIO 15 GFCI . C-1 A- 45"C- GFCI C-9 A- GFCI C-39 STUDIO 23 STUDIO 17 STUDIO 19 STUDIO 24 ////, A -A 45" C-17 ENTRY STUDIO 11 A- A GFCI GFCI B-22 // /// /7 /////// A-27 A A- GFCI WOMENS I I I I W/D i i W/D i ;W/D GFCI B-15 IVIECH.MEZZ BREAK RM 1e A_23j STUDIO 1 A- 45" B-1 ELECTRICAL POWER PLAN SCALE: 1/4" = 1-0" STUDIO 2 STUDIO 10 GFCI B-18 STUDIO 9 STUDIO 8 /////////////////////////// STUDIO 7 B-35 }AB-35 B-31 B-31 STUDIO 6 STUDIO 5 /7.///// //7/// /////////l7/ GFCI B-27 STUDIO 4 B-277 A- O B- 3FCI A B-23 B-2 A- 45" B-23 E & STUDIO 3 1. ALL CIRCUITS ON THIS SHEET TO PANEL 'B' (PP-1) UNLESS NOTED OTHERWISE. 2. REFER TO ARCHITECTURAL SHEET A1.5 FOR ADDFIIONAL NOTES AND MOUNTING HEIGHTS. PLAN NOTES: O 0 O O O NEW PANEL A. NEW PANEL B. NEVI PANEL C. SWITCH WIRED TO J-BOX 12' ABOVE FINISHED CEIUNG. DOOR KING SYSTEM. COORDINATE LOCATION IN FIELD. SEE SHEET A1.8 FOR MORE INFO. WITH PEDESTAL STAND.. STUDIO GFCI OUTLET TO BE EASILY ACCESSIBLE FOR STYLIST TO RESET IF NEEDED - DO NOT LOCATE ABOVE TALL STORAGE OR IN CABINET. PROVIDE TWO GFCI OUTLETS IN DOUBLE STUDIO'S. (TYP.) ELECTRICIAN TO PROVIDE WALL MOUNT TV RECEPTACLE OUTLET FOR ELECTRONIC DIRECTORY. COORDINATE LOCATION OF POWER/DATA NEEDS WITH OWNER. FURNISH AND INSTALL J-BOX 5'-6" A.F.F. FOR WALL SCONCE. SEE SHEET E1.4 FOR EXACT LOCATION AND CIRCUITING. SEE SCONCE DETAIL THIS SHEET. ELECTRICAL NOTES 1. ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND REPORT TO SYMPATECO, INC., IN WRITING / TELEPHONE: 1-800-652-1923, ANY DISCREPANCIES IMMEDIATELY UPON DISCOVERY. 4. UNLESS OTHERWISE NOTED, ALL TELEPHONE, ELECTRICAL, CABLE & DATA LINE OUTLETS SHALL BE LOCATED 18" ABOVE THE FINISHED FLOOR. 5. UNLESS OTHERWISE NOTED, DIMENSIONS FOR ALL NEW WORK ARE MEASURED FROM FACE OF GYPSUM BOARD. DIMENSIONS REFERRING TO EXISTING WORK ARE MEASURED FROM FACE OF EXISTING FINISH. 6. ALL ELECTRICAL DIMENSIONS ARE TO CENTER -LINE, ALL 'HOLD' DIMENSIONS ARE CRITICAL. 7. CHECK WITH OWNER RE: LOCATION OF TELEPHONE AND ALARM SYSTEM. ELECTRICIAN TO PROVIDE OUTLETS FOR THE DOOR / CAMERA SYSTEM AND DVD PLAYER. 8. ALL VISIBLE OUTLET COVERS TO BE STAINLESS STEEL. ALL OUTLET PLATES IN CABINETS AND NOT VISIBLE TO BE WHITE. 9. ELECTRICIAN TO PROVIDE CONNECTION TO WATER HEATER IGNITOR. 10. ELECTRICIAN TO PROVIDE CONNECTION TO STACKED WASHER/DRYER UNIT, CONFIRM THE POWER REQUIREMENTS WI MANUFACTURER. 11. G.C. TO VERIFY SECURITY CAMERA LOCATIONS AND MOUNTING HEIGHT WITH OWNER PRIOR TO INSTALLATION, UP TO 8 CAMERAS 12. ELECTRICIAN TO PROVIDE 40 AMPS TOTAL TO EACH STANDARD OR LARGE STUDIO (TWO 20 AMP CIRCUITS). ONE CIRCUIT IS DEDICATED TO OUTLET "C". DOUBLE STUDIOS REQUIRE 80 AMPS (FOUR 20 AMP CIRCUITS). 13. G.C. TO INSTALL TELEVISIONS WITH CEILING MOUNTING BRACKETS AND CABLING. VERIFY WITH OWNER. CABLES TO RUN TO DVD PLAYER IN THE LAUNDRY OR STORAGE ROOM. THREE TV'S PER CORRIDOR OR AS INDICATED. ELECTRICIAN TO PROVIDE OUTLETS. G.C. TO RUN CABLE FROM EQUIP. CLOSET TO ALL STUDIOS AND TIE UP ABOVE STUDIO CEILINGS. LABEL EACH LINE WITH STUDIO NUMBER. ELECTRICAL LEGEND $A DUPLEX - 120V- 15-20 AMP - HEIGHT BY CODE UNLESS NOTED OTHERWISE ON PLAN. GFCI AS REQUIRED BY CODE B 30 QUAD - 120V -20 AMP - 24" AFF O.C. (IN CABINET) UNLESS NOTED OTHERWISE. "B" OUTLETS ARE NOT SWITCHED. GFCI AS REQUIRED BY CODE. 4:0 3 -GANG -120V -20 AMP - 3 DUPLEX OUTLETS, 22" A.F.F. TO CENTER OF OUTLET, UNLESS NOTED OTHERWISE ON PLAN. GFCI AS REQUIRED BY CODE. ONE DEDICATED "C" OUTLET PER CIRCUIT. SEE TOOL CABINET SECTION FOR CABINET CLEARANCES. D DUPLEX - 120V- 15-20 AMP - 32" AFF O.C. UNLESS NOTED OTHERWISE. GFCI AS REQUIRED BY CODE. E DUPLEX - 120V- 20 AMP - INSTALL ON WALL CENTERED @ 6" AFF OR AS NEAR TO FLOOR AS POSSIBLE. LIGHT SWITCH Q TELEPHONE/DATA - (TYP.) CAT6 CABLING. 32" AFF O.C. UNLESS NOTED OTHERWISE. (VERIFY) 0 CABLE TV OUTLET A SECURITY CAMERAS (SEE ELECTRICAL NOTES) Nc"'3 CEILING MOUNT TV'S - 21" SILVER/GRAY-CHECK WITH OWNER RUN CABLE TO DVD PLAYER LOCATED IN LAUNDRY OR EQUIPMENT ROOM PROVIDE CAN OUTLET AND 120V. CEILING MOUNTED RECEPTACLES. ELECTRICAL LAYOUT & DETAILS co 0 co N 0 0 8 c c N CERTIFIED BY: 07/12/19 DRAWN BY: STAFF S'l'UIIDII03 GEORGE AND ELIZABETH MORRIS OWNER BUS.: 781-267-1399 CEL.: 781-267-1396 BANYAN CONSTRUCTION GENERAL CONTRACTOR JANSEN GEHRING PH.: 1312 259 7000 PROJECT: SL-MA-302 HIGHLAND AVE RELEASE DATE 6/17/19 REVISIONS: DRAWING NAME ELECTRICAL POWER PLAN SHEET NO. E1.2 GENERAL NOTES: 1. ALL CIRCUITS ON THIS SHEET TO PANEL 'B' UNLESS NOTED OTHERWISE. STUDIO 13 ////l////////////l//Z / ISTUDIO 14 5 ////M/z/M//////(/////m ISTUDIO 16 ///////////7/ /77/ //7///77/7 / /////////////////////////// STUDIO 20 5 STUDIO 21 13 7 // ELECTRICAL LIGHTING PLAN TI-1) (NL) X1 6 2 CEILING @ 10'-6" AFF X1 4 % % STUDIO 12 /////!/////r/////j//// STUDIO 15 STUDIO 17 STUDIO 19 6 3 STUDIO 11 MOP AO STUDIO 10 2 ////// /////I/// os 2 OS O A% 13 A 13 0 13 OF 13 13 frzsot4 /////////////////////////, ////////4 DA Aq 3 STUDIO 23 SCALE: 1/4" = 1'-0" ■ STUDIO 24 1 X1 • 4 (NL) 13 13 13 F WOMENS ;f /1Z/ZZ 10A 13 OS /////l/////// ///////// // 11 AO A011 AO 11 AO Ivi ECHMEZZ BREAK RM 1 4 EXI AO 1 LSTUDIO 1 6 STUDIO 2 ,X1 6 6 6 MENS X1 6 X1 (NL) mX 4 STUDIO 9 ////////Z/////////////////////// /i/i//7/7/ /ii//7 ////// STUDIO 7 / /// ///// ///// STUDIO 6 (') /Z/n//Z4Z7////////////////// STUDIO 3 2. REFER TO ARCHITECTURAL SHEET A1.6 FOR ADDITIONAL NOTES AND MOUNTING HEIGHTS. 3. TOILET EXHAUST FANS SHALL BE CONNECTED TO HALLWAY NIGHT CIRCUIT AS REQUIRED. LIGHTING NOTES 1. ALL WORK TO STRICTLY COMPLY WITH ALL FEDERAL, STATE & LOCAL CODES. 2. OWNER TO VERIFY WITH LANDLORD IF EXTERIOR SIGNS ARE ON COMMON ELECTRIC CIRCUIT FOR BUILDING OR TO BE ON SOLA CONTROLLED TIMER LOCATED IN EQUIPMENT # 2. 3. CORRIDOR LIGHTS AND SCONCES TO BE ON A TIMER. OVERRIDE SWITCHES AT ENTRANCES. 4. G.C. TO PROVIDE EXIT SIGNS, FIRE EXTINGUISHERS, EMERGENCY LIGHTS, ETC. AS REQUIRED BY LOCAL CODES. 5. ALL EMERGENCY AND EXIT LIGHTS SHALL BE BUILDING STANDARDS AND APPROVED BY OWNER. 6. EVERY THIRD LIGHT IN THE CORRIDOR IS TO BE A NIGHT LIGHT PER CODE. 7. ELECT. TO VERIFY ALL LOCATIONS OF SCONCES AFTER BOXES HAVE BEEN INSTALLED BUT BEFORE THE WIRING HAS BEEN PULLED IN CASE CHANGES ARE WANTED. CEILING PLAN LEGEND VERIFY ALL SELECTIONS WITH STORE OWNER SYMBOL DESCRIPTION O A RECESSED LED CAN LIGHT - COMMERCIAL ELECTRIC MODEL #CER6730MWH27 - OR APPROVED EQUAL 2' X 4' LED - METALUX TROFFER 24SR- 24SR-LD2-48-C-UNV-L840-CDI-U 1: C WALL SCONCE - 66" AFF - USE 25 WATT COMPACT FLUORESCENT LAMPS (120V). KAP DESIGN WILL PROVIDE THROUGH SOLA CORPORATE OFFICE: 303-377-7652 2' X 2' LED- METALUX TROFFER 22SR - 22SR-LD2-29-C-UNV-L835-CDI-U ® XI, DUAL HEAD EXIT LIGHT AND STANDARD EXIT LIGHT (AS REQUIRED BY CODE). EXIT SIGNS SHALL HAVE BATTERY BACKUP. 1«ICI DUAL HEAD LED EMERGENCY PACK WITH BATTERY BACK-UP. DUAL-LITE EV SERIES OR EQUIVALENT. X2' EXHAUST FAN -SHALL BE SWITCHED WITH ROOM LIGHTS AS REQUIRED. F OS CEILING SPEAKERS INSTALLED BY G.C. (TO BE TIED TO RADIO IN EQUIPMENT CLOSET OR LAUNDRY ROOM, CHECK WITH OWNER REGARD- ING SOUND SYSTEM.) ODRUM LIGHT TO BE DETERMINED, IF REQUIRED X 9 EXTERIOR EMERGENCY LIGHT TO BE DETERMINED WITH 90 MINUTE BATTERY BACK-UP NOTE: BULKHEADS PER SELECTION. ELECTRICAL LIGHTING PLAN CO 00 O d co 0 E 0 c 0 c 0 CERTIFIED BY: 07/12/19 DRAWN BY: STAFF I Wo KiH oy Z :(11.14111;11)° GEORGE AND ELIZABETH MORRIS OWNER BUS.: 781-267-1399 CEL.: 781-267-1396 BANYAN CONSTRUCTION GENERAL CONTRACTOR JANSEN GEHRING PH.: 1312 259 7000 PROJECT: S L-MA-302 HIGHLAND AVE RELEASE DATE 6/17/19 REVISIONS: DRAWING NAME ELECTRICAL LIGHTING PLAN SHEET NO. E1.4