Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
19027 116 HIGHLAND AVENUE MIXED USE RENOVATION PERMIT SET TIER 1 4-11-2019
CIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteTITLE SHEETMSDF19027T-100116 HIGHLAND AVENUE,SALEM, MA 01970116 HIGHLAND AVE116 HIGHLAND AVENUE, SALEM, MA 01970FLOW PROJECT #19027PERMIT SET4.12.2019AERIAL VIEWPROJECTLOCATIONGENERAL INFORMATIONPERSPECTIVE VIEWPROJECT TEAMN.T.SOWNER:NINA-SOTO & COMPANY6 LAURENT ROAD,SALEM, MA 01970T: (978) 836-0868CIVIL ENGINEER:BOBREK ENGINEERING &CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619ARCHITECTUREFLOW DESIGN50 GROVE STREET,SUITE 226SALEM, MA 01970T: (978) 818-5109The proposed project at 116 Highland Avenue willrenovate the second floor 2,119 square feetincluding three new dwelling units.FIRE PROECTION ENGINEERJFP SOLUTIONS, INC.P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-79991 4.12.2019 PERMIT SET ABBREVIATIONSA.C.P. ACOUSTIC CEILING PANELA/C AIR CONDITIONALUM ALUMINUMA.B. ANCHOR BOLT& ANDANGLEAPPROX. APPROXIMATELYARCH ARCHITECTURALA&G ASPHALT & GRAVELBL BASE LINEB.PL BASE PLATEBEAM BEAMBPC BED PANBLK'G BLOCKINGB.S. BOTH SIDESB.W. BOTH WAYSBOT BOTTOMBRK. BRICKBLD'G BUILDINGB/ BOTTOM OF - - -CPT. CARPETCLG CEILINGCL CENTER LINEC.T.C. CERAMIC TILE COVEC.T. CERAMIC TILECERM CERMAGUARDC.F. CEMENT FIBERBOARDC.L.F. CHAIN LINK FENCECR CHAIR RAILC.O. CLEAN OUTCLR. CLEAR(ANCE)CLSR. CLOSERCLS. CLOSETCHK COAT HOOKCOL. COLUMNC.M. COCOA MATCONC CONCRETEC.B. CONCRETE BLOCKCONC. BD. CONCRETE BOUNDC.M.U. CONCRETE MASONRY UNITCONSTR. CONSTRUCTIONCONT. CONTINUOUSC.J. CONTROL JOINTC.G. CORNER GUARDCORR. CORRIDORCTSK. COUNTERSUNKCRS. COURSECYL. CYLINDERC/H CEILING HEIGHTDEPT DEPARTMENTDEP DEPRESSIONDIAG DIAGONALDIAMETER, ROUNDDIM DIMENSIONDO. DITTODR DOORD.L. DOCK LEVELERD.A. DOUBLE ACTINGD.S. DOWNSPOUTD. DRAINDWG. DRAWINGD.W. DRYWALLEA. EACHE.F. EACH FACEE.W. EACH WAYELEC. ELECTRICE.W.C. ELECTRIC WATER COOLERELEV. ELEVATOR, ELEVATIONEL. ELEVATIONENCL. ENCLOSE, ENCLOSUREENG. ENGINEER(ING)ENT ENTRANCEEQ. EQUALEQUIP EQUIPMENTEXIST EXISTINGEXP EXPANSION, EXPOSEDE.B. EXPANSION BOLTE.J. EXPANSION JOINTEXTER EXTERIORF.B. FACE BRICKF/ FACE OF - - -F. TO F. FACE TO FACEFT. FEET, FOOTF.W. FIELD WELDFIN. FINISHF.E.C. FIRE EXTINGUISHER CABINETF.H.C. FIRE HOSE CABINETFLASH'G FLASHINGFLR. FLOORFLR'G FLOORINGF.D. FLOOR DRAINFLUOR. FLUORESCENTFTG FOOTINGFRT FIRE RETARDANT TREATEDFDN. FOUNDATIONF/H FULL HEIGHTFUS.LINK FUSIBLE LINKGA. GAGE OR GAUGEGALV GALVANIZEDG.C. GENERAL CONTRACTORGL. GLASSGB GRAB RAILGYP. BD. GYPSUM WALLBOARDG.W.B. GYPSUM WALLBOARDHDCP HANDICAPHDWR HARDWAREH.D. HEAVY DUTYHGT. , HT. HEIGHTH.C. HOLLOW COREH.M. HOLLOW METALHORIZ. HORIZONTALH.B. HOSE BIBBH.W.H. HOT WATER HEATERHUMI. HUMIGUARD CEILINGIN.(") INCHESK KIPLBL. LABELLAV. LAVATORYLG LENGTH, LONGLT'L LINTELLVR. LOUVERL.P. LOW POINTM.H. MANHOLEM MARBLEMAS. MASONRYM.O. MASONRY OPENINGMAT'L MATERIALMECH. MECHANICALMT'L MATERIALMIN. MINIMUMMISC. MISCELLANEOUSMTG. MOUNTINGNOM. NOMINALN.I.C. NOT IN CONTRACTN.T.S. NOT TO SCALENO., # NUMBERNC NURSE CALLOFF. OFFICEO.C. ON CENTEROP'G OPENINGOPP. OPPOSITEOZ. OUNCEO.D. OUTSIDE DIAMETERO.F. OUTSIDE FACEO.A. OVERALLO.H.D. OVERHEAD DOOROFI OWNER FURNISHED AND INSTALLEDOFCI OWNER FURNISHED CONTRACTOR INSTALLEDPT. PNEUMATIC TUBE SYSTEMPTD. PAINTEDPNL. PANELP/H PARTIAL HEIGHTP.F. PARTICLE FILLEDPTN. PARTITIONPLAS. PLASTICPL. PLASTICLP.LAM. PLASTIC LAMINATEPLUM. PLUMBINGLB. POUNDP.S.I. POUNDS / SQUARE INCHP.S.F. POUNDS / SQUARE FOOTPREF. PREFINISHEDP.M. PRESSED METALPROP. PROPERTY / PROPOSEDQ.T. QUARRY TILEQ.T.C. QUARRY TILE COVER. RADIUS / RISERREC RECEPTICLE / ELECTRICALRTPHREF REFERENCEREINF REINFORCE(ING)REM REMOVEREQ'D REQUIREDREV. REVISION / REVERSER.F. RIGID FRAMERD. ROADR.D. ROOF DRAINR.W.L. RAIN WATER LEADERRGH. ROUGHSECT SECTIONS.S. SERVICE SINKS/S STAINLESS STEELSH.V. SHEET VINYLS.W. SHOP WELDSL.DR. SLIDING DOORS.C. SOLID CORESPEC. SPECIFICATIONSPR. SPRINKLERSQ. FT. SQUARE FEETSTD. STANDARDST'L STEELSTRUC. STRUCTURALSUSP SUSPENDEDSYMM. SYMMETRICALTELE TELEPHONETLB THOUSAND POUNDTHR'D THRESHOLDTOIL. TOILETT/ TOP OF - - -TB TOWEL BARTRU-GLZ TRU-GLAZET. TREADTYP. TYPICALUC. UNDERCUTUNF UNFINISHEDU.N.O UNLESS NOTED OTHERWISEV.P. VENT PIPEVERT. VERTICALVIN. VINYLV.C.T. VINYL COMPOSITION TILEV.B.C. VINYL BASE COVEV.B.S. VINYL BASE STRAIGHTV.T.R. VENT THRU ROOFV.W.C. VINYL WALL COVERINGWSCT WAINSCOTW.C. WATER CLOSETWT WEIGHTW.W.F. WELDED WIRE FABRICW.G. WIRE GLASSW.M. WIRE MESHW/ WITHW/O WITHOUTWD. WOODWB. WOOD BASEW.P. WORKING POINTW.P. WATER PROOF1. PROTECTIONSPRINKLER:FIRE ALARM:SUPPRESSED AUTOMATIC SPRINKLER WILL BE PROVIDEDAUTOMATIC, SUPERVISED2. USE GROUP:B (BUSINESS) AND R-2 (RESIDENTIAL)3. CONSTRUCTION TYPE:VB4. HEIGHT/ AREA:2 STORIES INCLUDING STAIRS AT FRONT ANDREAR5. PROJECT AREA:2,436 SF FIRST FLOOR PLAN4,765 SF6. INTERIOR FINISHES AT PROJECT AREA:WALL/ CEILINGS:STAIRSCLASS BCORRIDORSCLASS BROOMS/ SPACESCLASS B (CLASS C - BEDROOMS)FLOORS:CLASS II7. EGRESS TRAVEL DISTANCE AT PROJECT AREA.EXIT ACCESS TRAVEL = 75 FT. MAX.DEAD END LIMIT = 20 FT. MAX.8. OCCUPANT LOAD AT PROJECT AREAPER DWELLING UNIT: 200 SF. PER OCCUPANT = 12 OCCUPANTSBUILDING DATA (NEWCOSTRUCTION):2,329 SF SECOND FLOOR PLAN4,765 SF TOTAL GROSS SQUARE FOOTAGE49'-3" PROVIDED TRAVEL DISTANCECODES & STANDARDSINTERNATIONAL PLUMBING CODE - 2015 WITH MA. AMENDMENTSIBC 2006A117.1 - 2003 AMERICANS WITH DISABILITIES ACT (ADA)INTERNATIONAL MECHANICAL CODE - 2015 WITH MA. AMENDMENTSMECHANICALNATIONAL ELECTRICAL CODE - 2015 WITH MA. AMENDMENTSACCESSIBILITYPLUMBINGELECTRICALBUILDINGNFPA - 101 - 2009 EDITION527 CMR 1.00STATE FIRE CODE SAF - C 6000 WITH MA. AMENDMENTSFIRE/LIFE SAFETYINTERNATIONAL ENERGY CONSERVATION CODE- 2015 EDITIONW/ MA. AMENDMENTSENERGYINTERNATIONAL BUILDING CODE 2015 WITH MA. AMENDMENTSINTERNATIONAL EXISTING BUILDING CODE 2015 WITH MA. AMENDMENTSGUIDELINES FOR DESIGN AND CONSTRUCTION OFRESIDENDIAL PROJECTS - 2015 WITH MA. AMENDMENTSRESIDENTIAL CODETYPES OF CONSTRUCTION:BUILDING ELEMENTSTYPE IATYPE II TYPE III TYPE IV TYPE VBABABABd ddHTFIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours)TABLE 601Structural frameIncluding columns, girders, trussesaBearing wallsExteriorInteriorfNonbearing walls and partitionsExteriorNonbearing walls and partitionsInterioreFloor constructionIncluding supporting beams andjoistsRoof constructionIncluding supporting beams andjoists3b2b101010HT3b2b110 21 20 1 01/HT3 22See Table 6020 0 0 0 0 0 1 0See 780 CMR602.4.62 2 101010HT11/21 1 0 1 0 1 0cHTc c c ccFor SI: 1 foot = 304.8mm.The structural frame shall be considered to be the columns and the girders, beams, trusses and spandrels having directconnections to the columns and bracing members designed to carry gravity loads. The members of floor or roof panelswhich have no connection to the columns shall be considered secondary members and not a part of the structuralframe.a.Roof supports: Fire-resistance ratings of structural frame and bearing walls are permitted to be reduced by onehourwhere supporting a roof only.b.An approved automatic sprinkler system in accordance with 780 CMR 903.3.1.1 shall be allowed to be substituted forone-hour-fire-resistance-rated construction, providing such system is not otherwise required by other provisions of780CMR or used for an allowable area increase in accordance with 780 CMR 506.3 or an allowable height increase inaccordance with 780 CMR 504.2. The one-hour substitution for the fire resistance of the exterior walls shall not bepermitted.d.Not less than the fire-resistance rating required by other sections of 780 CMR.e.Not less than the fire-resistance rating based on fire separation distance (see Table 602).f.ALLOWABLE AREA FACTORTABLE 506.2OCCUPANCYTYPE VABdR-27,000 SFSEE FOOTNOTESNSS13RSMS128,000 SF21,000 SF12,000 SF48,000 SF36,000 SFGENERAL LEGEND1 4DEMOLITION NOTE KEYEXISTING DOOR TOBE REMOVEDEXISTING PARTITIONTO BE REMOVEDEXISTING DOOREXISTING PARTITIONEXISTING GLAZINGEXISTING WALL PROTECTIONXXXXXXXXSECTION REFERENCENUMBERSECTIONREFERENCE SHEETDETAIL REFERENCENUMBERDETAIL REFERENCESHEETEXITHANDRAIL/CRASHRAIL INCORRIDOR (SEE DETAIL9/A703).6" CHAIR RAIL,ACROVYNPROTECTION BOARD,6" VYNIL BASE IN ALLPATIENT ROOMS(SEE ELEVATIONS).STRUCTURAL FLOORFILL AT SLAB. SEESTRUCTURALDRAWINGS FORREINFORCEMENTINFORMATIONXXXNEW DOOR WITHREFERENCE NUMBERNEW PARTITION TYPENEW GLAZING WITHREFERENCENUMBERNEW WALLPROTECTIONXXCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.As indicated\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteSHEET LIST, NOTESAND LEGENDSMSDF19027T-101116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019SHEET LISTSHEETNUMBERSHEET NAMEINITIAL ISSUEDATEDESCRIPTIONTITLE SHEETST-100 TITLE SHEET 4.12.2019 PERMIT SETT-101 SHEET LIST, NOTES ANDLEGENDS4.12.2019 PERMIT SETLIFE SAFETYLS-01 SECOND FLOOR LIFE SAFETYPLAN4.12.2019 PERMIT SETARCHITECTURALA-100 SITE PLAN 4.12.2019 PERMIT SETA-101 EXISTING LEVEL 1 4.12.2019 PERMIT SETA-102 EXISTING LEVEL 2 4.12.2019 PERMIT SETA-103 PROPOSED LEVEL 1 4.12.2019 PERMIT SETA-104 PROPOSED SECOND FLOORPLAN4.12.2019 PERMIT SETA-631 DOOR SCHEDULE AND DETAILS 4.12.2019 PERMIT SETAD-101 FIRST FLOOR DEMOLITION PLAN 4.12.2019 PERMIT SETAD-102 SECOND FLOOR DEMOLITIONPLAN4.12.2019 PERMIT SETFIRE PROTECTIONFP-01 LEVEL 1 FIRE PROTECTIONPLAN04/11/19 PERMIT SETFP-02 LEVEL 2 FIRE PROTECTIONPLAN04/11/19 PERMIT SETFP-03 ATTIC FIRE PROTECTION PLAN 04/11/19 PERMIT SET1 4.12.2019 PERMIT SET LIFE SAFETY LEGEND1 HOUR FIRE RATED BARRIERPROJECT SPECIFIC NOTES1 HOUR RATED SEPARATION PER IBC 2015 TABLE 508.2.5AILLUMINATED EXIT SIGNAGE;ARROWS INDICATE EXIT ROUTEFEFIRE ENTINGUISHERLENGTH OF TRAVEL - EGRESSPSPULL STATIONHORNSTROBEEXIT LOCATIONEXTERIOR EXIT DOORLENGTH OF TRAVEL - EGRESSFIRE EXTINGUISHERFEEL EMERGENCY LIGHTEGRESS PATHSDSMOKE DETECTORUNIT A3 BEDROOM997.6 SFUNIT B2 BEDROOM517.7 SFUNIT C2 BEDROOM549.4 SFEGRESS DISTANCE:41'-10"EGRESS DISTANCE:43'-11"EGRESS DISTANCE:49'-2"FEFEPSSDSDSDSDSDSDSDSDSDSDSDSDROOF BELOWPSCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.As indicated\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteSECOND FLOOR LIFESAFETY PLANMSDF19027LS-01116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019 1/4" = 1'-0"1SECOND FLOOR LIFE SAFETY PLAN1 4.12.2019 PERMIT SET +/- 1 2 2' - 11 3 /4 "+/- 105' - 8 5/8"+/- 141' - 7 3/4"HIGHLAND AVENAUMKEAG REALTYMANAGERMENT CORPSETBACK10' - 0"SETBACK30' - 0"SETBACK10' - 0"SETBACK15' - 0"CIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC. 1/8" = 1'-0"\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteSITE PLANLMDG19027A-100116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019 1/8" = 1'-0"1SITE PLANProjectNorthN08'12'16'4'Graphic Scale: 1/4 inch = 1 feet016'24'32'8'Graphic Scale: 1/8 inch = 1 feetGENERAL NOTES:1. ALL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF FRAMING. U.NO.2. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O.1 4.12.2019 PERMIT SET WAITING1TOILET2OFFICE3OFFICE4EXAM5MECH6MECH7STORAGE8MECH9ELECTRIC10EXAM11ENTRY12ADMIN13WAITING14ENTRY15STORAGE16TIOLET17EXAM18EXAM19UPUPUPCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC. 1/4" = 1'-0"\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteEXISTING LEVEL 1JGDF19027A-101116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019 1/4" = 1'-0"1EXISTING - FIRST FLOOR1 4.12.2019 PERMIT SET WAITINGROOMFILEROOMEXAMROOMEXAMROOMEXAMROOMEXAMROOMEXAMROOMOFFICEOFFICESUPPLYEXAMROOMEXAMROOMTOILETSUPPLYTOILETTREATMENTREMOVE EXISTING WALLS ASINDICATED,TYPDNDNCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC. 1/4" = 1'-0"\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteEXISTING LEVEL 2JGDF19027A-102116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019 1/4" = 1'-0"1EXISTING - SECOND FLOOR1 4.12.2019 PERMIT SET UPUPUPREMOVE WOOD STAIR ANDPARTITION WALLCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC. 1/4" = 1'-0"\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteFIRST FLOORDEMOLITION PLANLMDF19027AD-101116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019ProjectNorthN08'12'16'4'Graphic Scale: 1/4 inch = 1 feet016'24'32'8'Graphic Scale: 1/8 inch = 1 feetGENERAL NOTES:1. ALL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF FRAMING. U.NO.2. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O. 1/4" = 1'-0"1FIRST FLOOR DEMOLITION PLAN1 4.12.2019 PERMIT SET GENERAL NOTES:1. ALL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF FRAMING. U.NO.2. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O.WAITINGROOMFILEROOMEXAMROOMEXAMROOMEXAMROOMEXAMROOMEXAMROOMOFFICEOFFICESUPPLYEXAMROOMEXAMROOMTOILETSUPPLYTOILETTREATMENTREMOVE WOOD STAIR AND LOWPARTITION WALLREMOVE EXISTING FLOORINGDOWN TO SUBFLOOR AND PREPFOR NEW FINISHES, TYPSCOPE OF WORKREMOVE EXISTING WALLS ASINDICATED,TYPREMOVE AND SALVAGE EXISTINGDOORS AS INDICATED FORREUSE,TYPREMOVE AND SALVAGEEXISTING EXTERIOR DOORAS INDICATED,TYPREMOVE EXISTINGELECTRICAL PANEL.COORDINATERELOCATION WITHOWNEREXISTING WALLS TO REMAIN,TYPREMOVE AND SALVAGEEXTERIOR DOOR FRAME ANDHARDWAREDNDNCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.As indicated\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteSECOND FLOORDEMOLITION PLANMSDF19027AD-102116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019ProjectNorthN08'12'16'4'Graphic Scale: 1/4 inch = 1 feet 1/4" = 1'-0"1SECOND FLOOR DEMOLITION PLAN1 4.12.2019 PERMIT SET 3' - 6"1' - 0" MAX0' - 6" MAX3' - 6"1' - 6"2' - 10"2' - 0"3' - 6"MIRRORSOAPDISPENSERHANDSANITIZERPAPERTOWELDISPENSERBATHROOMHANDWASHSINKFACE OF WALL3' - 10"3' - 0"ADA CLOSETSHELF AN RODWALL MOUNTEDPHONEFIREEXTINGUISHERCABINET3' - 4"4' - 0"2' - 6"6' - 0"WALL MOUNTEDTELEVISION6' - 0"WIRELESSSYNCHRONIZEDCLOCK2' - 5"ELECTRICAL OUTLETTEL/DATAT EA4 PANEL HOLLOW METAL DOORREFER TO SCHEDULE.REFER TO DOOR SCHEDULE.BMETAL DOOR FRAMEREFER TO SCHEDULE.REFER TO DOOR SCHEDULEFIRE RATEDFIRE RATED4' - 0"7' - 0"CWOOD FLUSH DOORFIRE RATEDCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.As indicated\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rteDOOR SCHEDULE ANDDETAILSMSDF19027A-631116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019DOOR SCHEDULEDOOR WIDTH HEIGHTDOORTYPEFRAMETYPECOMMENTS201 3' - 0" 7' - 0" A B FIRED RATED DOOR AND DOOR FRAME213 3' - 0" 7' - 0" A B FIRED RATED DOOR AND DOOR FRAME220 3' - 0" 7' - 0" A B FIRED RATED DOOR AND DOOR FRAME 3/8" = 1'-0"TYPICAL MOUNTING HEIGHTS1 4.12.2019 PERMIT SET UPUP240WAITING228SPRINKLER ROOM229MECH230MECH231STORAGE232RESTROOM233OFFICE234EXAM235OFFICE236ELECTRIC237MECH238EXAM239EXAM240STORAGE241TIOLET242ENTRY243WAITING244ADMIN245ENTRY246EXAM2473' - 4"5' - 4"P1P1CIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC. 1/4" = 1'-0"\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rtePROPOSED LEVEL 1JG, LMDF19027A-103116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019 1/4" = 1'-0"1PROPOSED - FIRST FLOOR1 4.12.2019 PERMIT SET GENERAL NOTES:1. ALL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF FRAMING. U.NO.2. ALL INTERIOR DIMENSIONS ARE TO INTERIOR FACE OF GWB. U.N.O.FS1FS1FS1FS1ALIGNUNIT AUNIT BUNIT CMIN3' - 8"3' - 8" MINBEDROOM 2222P1LIVING/DINING202BATH203BEDROOM 3208BEDROOM 2206CLOSET207BEDROOM 1204CLOSET205KITCHEN201CLOSET209COMMONENTRY210CLOSET211CLOSET212LIVING/DINING214KITCHEN213BATH215BEDROOM 1216CLOSET217BEDROOM 2218CLOSET219LIVING/DINING221KITCHEN220CLOSET223BEDROOM 1224CLOSET225BATH226P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1ALIGNDNDNINFILLWALL2202139' - 10"6' - 0"9' - 10"ALIGNALIGNINFILL FLOOR ASINDICATED BYHATCH10' - 10"2' - 0"8' - 0"8' - 0"EQEQCLR5' - 0"ALIGNP1P12' - 2"2' - 4"2' - 0"CLR5' - 0"2' - 0"7' - 5"10' - 10"7' - 3"2' - 0"6' - 0"10' - 0"201CLR5' - 0"2' - 6"2' - 2"2' - 6"3' - 4"2' - 0"2' - 0"9' - 6"P1PARTITIONWALL TO UNDERSIDE OF DECKFIRERATINGULNUMBERTESTINGCODESSTC: NAUSG: NANANA5/8" GWB, BOTH SIDES3" SOUND ATTENUATIONBLANKET2 X 4 WOOD STUDS AT 16" O.C.FS1FIRE SEPARATION1 HOUR RATED WALLFIRERATINGULNUMBERTESTINGCODES1 HOURSTC: 49USG: 87.0717* EXTEND WOOD STUDS ANDPARTITION TO UNDERSIDE OF DECK5/8" TYPE X GWB, BOTH SIDES2 X 4 WOOD STUDS AT 16" O.C.* PROVIDE FIRESAFING MATERIALAT PARTITION AND CEILINGTRANSITION - SEE FIRESAFING DETAILON THIS SHEET3" SOUND ATTENUATIONBLANKET* SEE FIRE RATED PARTITION DETAILSON THIS SHEET FOR CONSTRUCTION OFFIRE RATED WALLS, TYPICAL4 3/4"4 3/4"* EXTEND WOOD STUD ANDPARTITION TO UNDERSIDE OF DECKU465CEILING ASSEMBLYFIRE RATED FLOOREXISTING WOOD JOISTFIRE TREATED WOODBLOCKING AT TOP OFPARTITION1" GYP-CRETE OVEREXISTING SUBFLOOR3/4" PLYWOOD SUBFLOOR5/8" TYPE X GWBCONTINUOUS ON BOTH SIDESBATT INSULATION2" X WOOD STUD @ 16" O.C.1 HOUR FIRE SAFING5/8" INTERIOR GWBCIVIL ENGINEER:DRAWING TITLE:DRAWING NO.:SEAL:DRAWN BY:CHECKED BY:SCALE:PROJECT NO.:PROJECT LOCATION:REVISION:NO:DATE:DESCRIPTION:DATE:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF FLOWDESIGN INC. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT ASINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVEREDUNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESEPLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUTPRIOR WRITTEN PERMISSION OF FLOW DESIGN INC. AND THE ARCHITECT WHOSE SIGNATURE AND SEALMAY BE AFFIXED TO THESE DRAWINGS.© 2019 Flow Design Inc.ARCHITECT:ARCHITECTUREPLANNINGINTERIOR DESIGNGRAPHIC DESIGNSALEM47 BRIDGE STREETSALEM, MA 01970TEL. 978.818.5109DIGITAL ILLUSTRATIONRESIDENTIAL DESIGNFIRE PROTECTION ENGINEER:BOBREK ENGINEERING & CONSTRUCTION141 PINE STREET,DANVERS, MA 01923EMAIL: INFO@GOBOBREK.COMT: (978) 406-9619P.O. BOX 1234LYNNFIELD, MA 01940T: (781) 389-7999JFP SOLUTIONS, INC.As indicated\\flow\Projects\Architecture\2019\19027 116 HIGHLAND AVE MIXED USEPROJECT\A_Revit\19027 116 HIGHLAND AVENUE 4-10-2019.rtePROPOSED SECONDFLOOR PLANMSDF19027A-104116 HIGHLAND AVENUE,SALEM, MA 019704.12.2019ProjectNorthN08'12'16'4'Graphic Scale: 1/4 inch = 1 feet 1/4" = 1'-0"1PROPOSED SECOND FLOOR PLAN 1 1/2" = 1'-0"FIRE RATED PARTITION DETAIL AT FLOOR/CEILING ASSEMBLY 3" = 1'-0"TYPICAL DETAIL AT FIRE RATED INTERSECTION1 4.12.2019 PERMIT SET