100617-CFP640-FP-4-River Rock TownhouseP► N ROOF BELOW (171 6'-10 FS1 L%a 6'-9% FS1 �--- _-- Oa 1 % 7'-8'1AA BEDROOM m rn 1 1/4 " 1% 2'-9 BATH 3 1% 9'5% T MAS ER; SUlitE 1 1'-8 TH UNIT #72 BEDROOM 1" UP TO SIDEWALL SPRINKLER 1-1/4" UP TO SIDEWALLS 2" FROM BELOW 1 a \ BALCONY BEDROOM 1% 10' 3% 6'-5% 0'-8% 3'-714 2'-1136 2'-3% FS1 FS1 Oa UNIT 1" UP TO SIDEWALL SPRINKLER Hydraulic Information Remote Area 1- Unit 72 2nd OCCUPANCY CLASSIFICATION Residential DENSITY 0.100gpm/ft2 for 900.00ft2 (Actual 330.59ft2) TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 4 K-FACTOR 5.8 TOTAL WATER REQUIRED 200.89 TOTAL PRESSURE REQUIRED 63.137 BASE of RISER (gpm) 100.89 BASE of RISER (psi) 54.565 SAFETY MARGIN (psi) +8.778 (12.2%) 2" FROM BELOW 1-1/2" UP TO SIDEWALLS ROOF BELOW 6'-10 BALCONY • BEDROOM 13'-8" X 12' 1 " j 1 B ~N,_61-534 --r STER SU TE 1" UP TO SIDEWALL SPRINKLER 71-11 BALCONY 1 4'-6% 1 *ROOM 13'-8" X 12'-1" rr 1 3�4-y 0 ROOF BELOW 2" FROM BELOW 1-1/2" UP TO SIDEWALLS 6'-9'% 2" FROM BELOW 1-1/2" UP TO SIDEWALLS BATH • 1" UP TO SIDEWALL SPRINKLER Ifl' BALCONY 3'-2'% ROOF P#OkuT 6'-91A BEDROOM 13'-8" X ' 1% 1'% ''1 3'-7% 0'-8% 2'-3 BEDROOM TH IT #80 8'-0 1" UP TO SIDEWALL SPRINKLER 2" FROM BELOW 1-1/4" UP TO SIDEWALLS BEDROOM UNIT #8' 6'-10 BEDROCK 1" UP TO SIDEWALL SPRINKLER ROOF BELOW 0 0 Ot m W 1- 0 INSTALLATION INFORMATION MAXIMUM DISTANCE BETWEEN HANGERS 0 .,;.,-1Zo 2 0 ti 2 0O ti < ti z e 0 - ` z .-1z < O O O O m N N N Q O O O 0 - N N L\ N "i N ti 0 0 TN 0 '^ CVN - - 9 CO IN .- - 0 ,n 1-1 0 rry N O 0 N 0 N cr 0 0 o '- N N O w ,-I ,-If+ N O O O O N - O CO a ` < o .o m z `z w ,+ NOMINAL PIPE SIZE (in.) STEEL PIPE EXCEPT THREADED THREADED LIGHTWALL COPPER TUBE 0 n 0 Contractor: DiFava Fire Protection 4 Sheridan Road Wilmington, MA 01887 Project: River Rock Residences Townhouses 72-82 Boston Street Salem, MA SECOND FLOOR Design Project# CFP640 1 .5 0 III SCALE 1/4"=1'-0" Drawn by: REC & RPG Date: 10/5/2017 Approval by: Fire Dept. SHEET NUMBER FP-4 OF 5 NOTE: USE OF THESE PLANS BY THE INSTALLING CONTRACTOR SHALL INDICATE ACCEPTANCE OF ALL THE INFORMATION PROVIDED ON THESE PLANS AND SHALL TRANSFER FINAL RESPONSIBILITY OF THE CORRECTNESS OF THE SYSTEM TO THE INSTALLING CONTRACTOR. ANY DESIGN ERRORS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. NOTE: ADDITIONAL SPRINKLER HEADS OVER AND ABOVE THOSE SPECIFICALLY NOTED ON THESE DRAWINGS MAYBE REQUIRED DEPENDING ON THE REQUIRED ROUTING AROUND TRUSSES, HVAC DUCTWORK, HOODS AND OTHER SIMILAR OBSTRUCTIONS. FIELD VERIFY EXIST ING CONDITIONS DURING CONSTRUCTION AND PROVIDE ANY AND ALL ADDITIONAL HEADS AS REQUIRED FOR FULL COVERAGE AND A COMPLETE, CODE COMPLIANT SYSTEM.