100617-CFP640-FP-1-River Rock Townhouse4" TO DRY SYSTEM SPRINKLERS BUILDING SECTION WET PIPE SYSTEM Minimum Flow and Residual Pressure(b• c) Minimum Spacing Ft. (m) Max.Cov Area Area tat Ft. x Ft. (m x m) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175'F (79'C) Deflector to Ceiling Installation Type Flow gpm (Ipm) Pressure psi (bar) Flow gpm (Ipm) Pressure psi (bar) 12 x 12 16 7.6 16 7.6 Smooth (3.7 x 3,7) (60.6) (0,52) (60.6) (0,52) Ceilings 1 to 14 x 14 16 7.6 16 7.6 4 inches Recessed (4,3 x 4.3) (60,6) (0,52) (60,6) (0,52) Beamed using Style 20 16 x 16 16 7.6 16 7.6 Ceilings per Escutcheon or 8 (4,9 x 4,9) (60,6) (0,52) (60,6) (0,52) NFPA 13D non -recessed (2.4) 18 x 18 18 9.6 18 9,6 or 13R per NFPA 13D, (5,5 x 5,5) (68,1) (0,66) (68,1) (0,66) 1 to 1-3/4 inches below 13R, or 13 20 x 20 20 11.9 20 11.9 bottom of (6,1 x 6,1) (75,7) (0,82) (75,7) (0,82) beam. a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used, TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY3934) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA 4" TO FIRE DEPARTMENT CONNECTION. LOCATE PER LOCAL FIRE DEPARTMENT REQUIREMENTS. 2" MAIN DRAIN. PIPE TO EXTERIOR. 4" CHECK VALVE NOTE: COMBUSTIBLE CONCEALED SPACES ABOVE CEILINGS ARE FILLED WITH INSULATION. FIRE SPRINKLERS ARE NOT REQUIRED. Max. Coverage Areal* Max, SPacieg FLYBS'F Oa) Minimum Flow and Residual Pressurela '1 Ordinary Temp. Rating (Mt) Intermediate Temp. Rating 175'F T79'CI Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) wWfle x Lengthy Ft. x Ft. (m x m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 12 17 9.2 17 9.2 (3,7 x 3,7) (3,7) (64,3) (0.63) (64,3) (0.63) 14 x 14 14 19 11.5 19 11.5 (4,3 x 4,3) (4,3) (71,9) (079) (71,9) (0.79) 16 x 14 16 20 12.8 20 12.8 (4.9 x 4,3) (4,9) (75.7) (0,88) (75.7) (0.88) 4 to 16x16 16 24 18.4 24 IBA 6inches (4,9 x 4,9) (4,9) (90.8) (1,27) (90,81 (1,27) 16x18 16 26 21.6 26 21.6 (4,9 x 5.5) (4,9) (98.4) (1,49) j98,4) (1.49) 1/2 inch 16 x 20 16 29 26.8 29 26.8 recessed us- (4.9 x 6.1) (4,9) (109,8) (1,85) (109.81 (1.85) ing Style 20 8 or2 Escutcheon(,4) non -recessed 12 x 12 12 20 12.8 20 12.8 (3,7 x 3.7) (3,7) (75.7) (0,88) (75,7) 40,881 per NFPA 13D, 14 x 14 14 22 15.4 22 15.4 13R, or13 (4,3 x 4,3) (4,3) (83,3) (1,06) (83.3) (1,06) 16 x 14 16 24 /6.4 24 18.4 (4,9 x 4,3) (4,9) (90.8) (1,27) (90,8) (1,27) 6to 16 x 16 16 28 25.0 28 25.0 12 inches (4,9x4,9) (4,9) (106,0) (1,72) (106,0) (1,72) 16 x 18 16 31 30.6 31 30.6 (4,9 x 5,5) (4,9) (117,3) (2.11) (117.3) (2,11) 16 x 20 16 37 43.7 37 43.7 (4,9 x 6,1) (4,9) (140,0) (3,01) (140,0) (3,01) a dmenson ten than « between those indicated. nee the mania. n roamed now to the near highest coverage soma ler welch hNreubc loco c,Iwiw ate Rpwamenl Fs based an minimum Now in 0#M iLPM} Iran each weeder. The assocrald snicks* ptaserxo W. c*clited ,eh* tla nmNr"l wtm^tm. Rex 10 Hpreuee Desgn alder the Design criteria eecbm. NFPA t] methane* w04 a0ww,t*9re*err OF 0.1 g o,1V a.w the design ere orthe Mwheaco"da"® welt Ole oaten& In Ihislide mall be used. it the widenxlength amanion meet to tee Widm(oxkwall when the spr,xle, la letatedt times the targer, carbonMmw W wx*kle4 TABLEA WET PIPE SYSTEMS SERIES LFII (TY3334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY3334) NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA Sprinkler Legend Symbol SIN Model Quantity K-Factor Type Thread Size Response Finish Temperature Note TY-FRB 67 5.6 Pendent % Quick Chrome 155°F Commercial •TY3231 TY3934 LFII 86 5.8Pendent IA Quick White 155'T Residential -44 TY3334 LFII 36 5.6 Sidewall '/2 Quick Chrome 155"F Residential TY3331 TYFRB 6 5.6 Sidewall 34 Quick Chrome 155`F Commercial Total = 195 4" TO WET SYSTEM SPRINKLERS WATERFLOW SWITCH 4" BUTTERFLY VALVE 4" UNDERGROUND SUPPLY 4" AMES COLT C200 BACKFLOW PREVENTER SYSTEM RISER DETAIL NV 8.15.7.2* Sprinklers shall be permitted to be omitted where the exterior projections are constructed with materials that are noncombustible, limited -combustible, or fire retardant -treated wood as defined in NFPA 703. 8.15.7.3 Sprinklers shall be permitted to be omitted from below the exterior projections of combustible construction, provided the exposed finish material on the exterior projections are noncombustible, limited -combustible, or fire retardant -treated wood as defined in NFPA 703, and the exterior projections contain only sprinklered concealed spaces or any of the following unsprinklered combustible concealed spaces: (1) Combustible concealed spaces filled entirely with non- combustible insulation (2) Light or ordinary hazard occupancies where noncombustible or limited -combustible ceilings are directly attached to the bottom of solid wood joists so as to create enclosed joist spaces 160 cubic ft or less in volume, including space below insulation that is laid directly on top or within the ceiling joists in an otherwise sprinklered attic [see 11.2.3.1.4(4)(d)] (3) Concealed spaces over isolated small exterior projections not exceeding 55 sqft INSTALL NEW 4" FDC, 2" MAIN DRAIN, AND ELECTRIC BELL LOCATE PER LOCAL FIRE DEPARTMENT REQUIRMENTS 20" UNDERGROUND STREET MAIN SITE PLAN Supply Flow Test Data Date of Test 12/7/2016 Location Boston Street Static Pressure 72.000 Residual Pressure: 70.000 Flow 1106.00 Hydrant Elevation Level with BOR Project Narrative 1- Building Description: * Wood Frame Construction. * Building Footprint = 4,200 sqft approximately * Floors above grade = 3 * Floors below grade = 1 * Occupancies= Residential * Hazardous materials = None known * High storage = None known 2 - Applicable Laws, Regulations, Standards: • NFPA 13 (2013) Installation of Sprinkler Systems * Underwriters Laboratories Inc. Publications * Manufacturer's Listed and Approved Design/Installation/Maintenance Manuals 3 - Design Responsibility for Fire Protection Systems: * Shop drawings developed by Comprehensive Fire Protection LLC. * Fire Alarm by others * Kitchen/Cooking suppression by others * Underground fire service by others * Manual suppression systems by others * Smoke control systems by others 4 - Fire Protection Systems to be installed: The fire protection project consists of installing new sprinklers and pipe in a new building. The system riser consists of a 4" Storz FDC, 4" wet riser, 3" dry riser, 4" water supply, and all other required valves and fittings. 5 - Design Methodology: Fire Sprinkler System Design Parameters: * System(s) design to be per NFPA 13 (2013), local and State code. * Sprinklers on 1st through 3rd floors to be residential type, white coated, recessed pendents or sidewalls. * Sprinklers on garage level to be commercial type. * Install sidewall sprinklers to protect under garage doors. * Calculation area within dwelling units to be the most hydraulically demanding 4 sprinklers calculated to .10 density over the actual area protected. * Calculation of sprinklers in the storage area to be at a density of .20 over 900 sqft using the quick response area reduction allowance. * Calculation of sprinklers in the garage to be at a density of .15 over 1950 sqft after increasing the area by 30% for being a dry system. * The garage and sprinkler room is protected by the dry system. All other areas are protected by the wet system. * Install a zone control assembly for each townhouse unit as shown. * Install steel schedule 10 with grooved fittings or steel schedule 40 with threaded fittings on the garage level. * Install cpvc sprinkler pipe on levels 1-3. CODE REFERENCES: * Design and installation to conform to NFPA 13, 2013 editions. * Design and installation to conform to State Code, Local Fire and Building Departments. 6 - Special considerations and descriptions: * No official code interpretations. * No official waivers or variances. 7 - Sequence of operation: * Fire sprinkler activates. * Water starts flowing and activates the water flow switch. * Water flow switch sends alarm signal to alarm panel and Fire Department. * Building alarm is activated. 8 - Testing criteria: * Tests will be conducted to the satisfaction of local authorities. * Tests to be set up and scheduled by the contractor. * Water will be flowed from the inspector's test valve. * Pipes to be pressure tested to 200 psi for two hours. * All alarm and tamper switches to be tested for proper activation. * Written approval of final tests to be obtained from the code official. * Required fire sprinkler and aboveground piping reports to be submitted to the code officials. HANGER NO. 15W SIDE SAMMY SCREW Side Sammy Screew All Thread Rod Swivel Ring Note on Plan. Hanger Number and 'A' Dimension w 1— cC 0 [STALLATION INFORMATION [MAXIMUM DISTANCE BETWEEN HANGERS ° O "' ay 2 9 - < z o -2-2 FM 0 ¢ o Cr or)2 ti N ti 2 0 0 0 0 0 0 4 0 N .. - ri 0 O isa id:, h '• -1 A7 - 00 0 0 0 0 LA .y n - 0 ' r ,-1 o r - 0 A ,-1- 0 o co 9 0 0 0 - - 00 io 0 '0 m 2 Z 0 s NOMINAL PIPE SIZE (in.) ISTEEL PIPE EXCEPT I THREADFD ITH LIGHTWALREADEDL COPPER TUBE > a. Contractor: DiFava Fire Protection 4 Sheridan Road Wilmington, MA 01887 Project: River Rock Residences Townhouses 72-82 Boston Street Salem, MA DETAILS & NOTES Design Project# CFP640 Drawn by: REG & RPG Date: 10/5/2017 Approval by: Fire Dept. SHEET NUMBER FP-1 OF 5 NOTE: USE OF THESE PLANS BY THE INSTALLING CONTRACTOR SHALL INDICATE ACCEPTANCE OF ALL THE INFORMATION PROVIDED ON THESE PLANS AND SHALL TRANSFER FINAL RESPONSIBILITY OF THE CORRECTNESS OF THE SYSTEM TO THE INSTALLING CONTRACTOR. ANY DESIGN ERRORS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. NOTE: ADDITIONAL SPRINKLER HEADS OVER AND ABOVE THOSE SPECIFICALLY NOTED ON THESE DRAWINGS MAYBE REQUIRED DEPENDING ON THE REQUIRED ROUTING AROUND TRUSSES, HVAC DUCTWORK, HOODS AND OTHER SIMILAR OBSTRUCTIONS. FIELD VERIFY EXISTING CONDITIONS DURING CONSTRUCTION AND PROVIDE ANY AND ALL ADDITIONAL HEADS AS REQUIRED FOR FULL COVERAGE AND A COMPLETE, CODE COMPLIANT SYSTEM.