Loading...
PE STAMPED THERMAL CIRCUITS CALC AREA 2 10-13-17EBACHER FIRE PROTECTION MA LICENSE SC 210058 40 PORTSMOUTH ROAD AMESBURY, MA 01913 978-388-4086 Job Name : THERMAL CIRCUITS COMPILED A2 Building : ONE TECHNOLOGY WAY Location : SALEM, MA 01970 System : 2 Contract : Data File : THERMAL CIRCUITS COMPILED 10-11-17 CALC Area 2.WXF Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 1 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 HYDRAULIC CALCULATIONS for Project name:THERMAL CIRCUITS COMPILED Location:SALEM, MA 01970 Drawing no:ONE TECHNOLOGY WAY Date:10-11-17 Design Remote area number:2 Remote area location:OFFICE AREA - 2ND FLOOR Occupancy classification:LIGHT HAZARD Density:0.10 - Gpm/SqFt Area of application:953 - SqFt Coverage per sprinkler:120 - SqFt Type of sprinklers calculated:PENDENT No. of sprinklers calculated:11 In-rack demand: - GPM Hose streams:250 - GPM Total water required (including hose streams):425.08 - GPM @ 36.646 - Psi Type of system:WET Volume of dry or preaction system: - Gal Water supply information Date:04-26-17 Location:BUILDING AT SITE Source:HAYES ENGINEERING, INC. Name of contractor:EBACHER FIRE PROTECTION Address:MA LICENSE SC 210058 / 40 PORTSMOUTH ROAD / AMESBURY, MA 019 Phone number:978-388-4086 Name of designer:R. LARKIN Authority having jurisdiction:SALEM FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) NFPA 13, 2013 EDITION, PARA. 11.2.3.2.3.1 DESIGN AREA REDUCTION AS SHOWN IN FIGURE 11.2.3.2.3.1. Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTIONPage 2 THERMAL CIRCUITS COMPILED A2Date 10-11-17 10203040E50R60U70S80S90E100R110P120130140150200 400 600 800 1000 1200 1400 1600 1800FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 90 C2 - Residual Pressure: 88 C2 - Residual Flow : 1403 D1 - Elevation : 10.793 D2 - System Flow : 175.08 D2 - System Pressure : 36.646 Hose ( Demand ) : 250 D3 - System Demand : 425.08 Safety Margin : 53.134 D1D2D3Water Supply Curve CComputer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 3 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 14.8 DP01 EQ01 14.8 DP02 EQ02 14.8 44.8 158 175.1 175.1 175.1 175.1 175.1 201 202 203 204 205 206 WP3 WP2 TOR2 WP1 TOR BOR BASE UG1 UG2 UG3 TEST |29.7|125.8 175.1 175.1 175.1 175.1 175.1 175.1 |14.9|29.7 14.9 207 208 202 14.9 15.1 209 203 81.1 47.8 16.6 204 210 211 212 213 214 64.4 |47.8 |47.8 15.6 31.3 215 216 217 213 15.6 |15.6 15.7| 218 217 16 32.1 219 220 221 205 16 |16 16.1| 222 221 17.1 223 206 Flow Diagram Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTIONPage 4 THERMAL CIRCUITS COMPILED A2Date 10-11-17 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 6071 81 91 101 121 Zac Ames 2000SS Fitting generates a Fixed Loss Based on Flow Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 5 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. DP01 21.92 5.6 7.0 na 14.82 0.1 120 7.0 EQ01 24.92 7.05 na DP02 21.92 5.6 7.0 na 14.82 0.1 120 7.0 EQ02 24.92 6.82 na 201 24.92 K = K @ EQ02 6.82 na 14.82 202 24.92 7.46 na 203 24.92 7.56 na 204 24.92 8.91 na 205 24.92 9.3 na 206 24.92 9.99 na WP3 24.92 14.62 na WP2 24.92 16.6 na TOR2 24.92 16.89 na WP1 14.0 22.35 na TOR 14.0 24.38 na BOR 3.0 32.45 na BASE 3.0 35.05 na UG1 0.0 36.45 na UG2 0.0 36.53 na UG3 0.0 36.6 na TEST 0.0 36.65 na 250.0 207 24.92 K = K @ EQ02 6.88 na 14.89 208 24.92 7.37 na 209 24.92 K = K @ EQ02 7.06 na 15.08 210 24.92 K = K @ EQ01 8.91 na 16.66 211 24.92 K = K @ EQ01 8.81 na 16.57 212 24.92 8.81 na 213 24.92 8.8 na 214 24.92 K = K @ EQ01 8.79 na 16.55 215 24.92 K = K @ EQ02 7.56 na 15.6 216 24.92 8.05 na 217 24.92 8.14 na 218 24.92 K = K @ EQ02 7.64 na 15.68 219 24.92 K = K @ EQ02 7.96 na 16.0 220 24.92 8.44 na 221 24.92 8.57 na 222 24.92 K = K @ EQ02 8.08 na 16.12 223 24.92 K = K @ EQ02 9.11 na 17.12 The maximum velocity is 10.3 and it occurs in the pipe between nodes 206 and WP3 Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 6 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn DP01 14.82 1.049 T 5.0 13.000 7.000 K Factor = 5.60 to 120.0 0.0 5.000 -1.299 EQ01 14.82 0.0747 0.0 18.000 1.344 Vel = 5.50 0.0 14.82 7.045 K Factor = 5.58 DP02 14.82 1.049 E 2.0 13.000 7.000 K Factor = 5.60 to 120.0 0.0 2.000 -1.299 EQ02 14.82 0.0747 0.0 15.000 1.120 Vel = 5.50 0.0 14.82 6.821 K Factor = 5.67 201 14.82 1.049 T 5.0 3.500 6.821 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 202 14.82 0.0747 0.0 8.500 0.635 Vel = 5.50 202 14.88 1.61 0.0 3.190 7.456 to 120.0 0.0 0.0 0.0 203 29.7 0.0335 0.0 3.190 0.107 Vel = 4.68 203 15.08 1.61 T 8.0 10.810 7.563 to 120.0 0.0 8.000 0.0 204 44.78 0.0718 0.0 18.810 1.350 Vel = 7.06 204 81.06 2.635 0.0 8.820 8.913 to 120.0 0.0 0.0 0.0 205 125.84 0.0441 0.0 8.820 0.389 Vel = 7.40 205 32.12 2.635 E 8.237 2.090 9.302 to 120.0 0.0 8.237 0.0 206 157.96 0.0671 0.0 10.327 0.693 Vel = 9.29 206 17.12 2.635 T 16.474 40.450 9.995 to 120.0 0.0 16.474 0.0 WP3 175.08 0.0812 0.0 56.924 4.621 Vel = 10.30 WP3 0.0 3.26 E 9.408 59.470 14.616 to 120.0 0.0 9.408 0.0 WP2 175.08 0.0288 0.0 68.878 1.983 Vel = 6.73 WP2 0.0 4.26 E 13.167 24.340 16.599 to 120.0 0.0 13.167 0.0 TOR2 175.08 0.0078 0.0 37.507 0.293 Vel = 3.94 TOR2 0.0 4.26 T 26.334 40.160 16.892 to 120.0 2E 26.334 52.668 4.729 WP1 175.08 0.0078 0.0 92.828 0.727 Vel = 3.94 WP1 0.0 4.26 T 26.334 167.200 22.348 to 120.0 5E 65.835 92.169 0.0 TOR 175.08 0.0078 0.0 259.369 2.029 Vel = 3.94 TOR 0.0 4.26 Fsp 0.0 11.000 24.377 to 120.0 B 15.8 28.967 7.764 * Fixed Loss = 3 BOR 175.08 0.0078 E 13.167 39.967 0.313 Vel = 3.94 BOR 0.0 4.26 Zac 0.0 6.000 32.454 to 120.0 E 13.167 13.167 2.450 * Fixed Loss = 2.45 BASE 175.08 0.0078 0.0 19.167 0.150 Vel = 3.94 BASE 0.0 6.16 G 4.304 35.000 35.054 to 140.0 T 43.037 67.425 1.299 UG1 175.08 0.0010 E 20.084 102.425 0.100 Vel = 1.88 Final Calculations - Hazen-Williams - 2007 Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 7 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG1 0.0 8.27 E 28.468 310.000 36.453 to 140.0 0.0 28.468 0.0 UG2 175.08 0.0002 0.0 338.468 0.079 Vel = 1.05 UG2 0.0 8.27 G 6.326 202.000 36.532 to 140.0 E 28.468 90.148 0.0 UG3 175.08 0.0002 T 55.354 292.148 0.068 Vel = 1.05 UG3 0.0 10.28 2E 66.296 420.000 36.600 to 140.0 G 7.534 149.166 0.0 TEST 175.08 0.0001 T 75.336 569.166 0.046 Vel = 0.68 250.00 Qa = 250.00 425.08 36.646 K Factor = 70.22 207 14.89 1.049 T 5.0 1.490 6.885 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 208 14.89 0.0753 0.0 6.490 0.489 Vel = 5.53 208 0.0 1.61 0.0 8.810 7.374 to 120.0 0.0 0.0 0.0 202 14.89 0.0093 0.0 8.810 0.082 Vel = 2.35 0.0 14.89 7.456 K Factor = 5.45 209 15.08 1.049 T 5.0 1.490 7.063 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 203 15.08 0.0770 0.0 6.490 0.500 Vel = 5.60 0.0 15.08 7.563 K Factor = 5.48 204 -81.06 4.26 0.0 1.500 8.913 to 120.0 0.0 0.0 0.0 210 -81.06 -0.0020 0.0 1.500 -0.003 Vel = 1.82 210 16.66 2.635 0.0 7.700 8.910 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 211 -64.4 -0.0127 0.0 7.700 -0.098 Vel = 3.79 211 16.57 4.26 0.0 1.130 8.812 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 212 -47.83 -0.0009 0.0 1.130 -0.001 Vel = 1.08 212 0.0 2.635 0.0 1.870 8.811 to 120.0 0.0 0.0 0.0 213 -47.83 -0.0075 0.0 1.870 -0.014 Vel = 2.81 213 31.28 2.635 0.0 5.000 8.797 to 120.0 0.0 0.0 0.0 214 -16.55 -0.0010 0.0 5.000 -0.005 Vel = 0.97 0.0 -16.55 8.792 K Factor = -5.58 215 15.60 1.049 T 5.0 1.000 7.561 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 216 15.6 0.0822 0.0 6.000 0.493 Vel = 5.79 216 0.0 1.61 0.0 8.000 8.054 to 120.0 0.0 0.0 0.0 217 15.6 0.0101 0.0 8.000 0.081 Vel = 2.46 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.1 EBACHER FIRE PROTECTION Page 8 THERMAL CIRCUITS COMPILED A2 Date 10-11-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 217 15.68 1.61 T 8.0 9.920 8.135 to 120.0 0.0 8.000 0.0 213 31.28 0.0369 0.0 17.920 0.662 Vel = 4.93 0.0 31.28 8.797 K Factor = 10.55 218 15.68 1.049 T 5.0 1.000 7.638 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 217 15.68 0.0828 0.0 6.000 0.497 Vel = 5.82 0.0 15.68 8.135 K Factor = 5.50 219 16.00 1.049 T 5.0 0.670 7.955 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 220 16.0 0.0861 0.0 5.670 0.488 Vel = 5.94 220 0.0 1.61 0.0 12.000 8.443 to 120.0 0.0 0.0 0.0 221 16.0 0.0108 0.0 12.000 0.129 Vel = 2.52 221 16.12 1.61 T 8.0 10.810 8.572 to 120.0 0.0 8.000 0.0 205 32.12 0.0388 0.0 18.810 0.730 Vel = 5.06 0.0 32.12 9.302 K Factor = 10.53 222 16.12 1.049 T 5.0 0.670 8.076 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 221 16.12 0.0875 0.0 5.670 0.496 Vel = 5.98 0.0 16.12 8.572 K Factor = 5.51 223 17.12 1.049 E 2.0 2.090 9.108 K Factor @ node EQ02 to 120.0 T 5.0 7.000 0.0 206 17.12 0.0976 0.0 9.090 0.887 Vel = 6.36 0.0 17.12 9.995 K Factor = 5.42 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.53.1