Date: 6/29/2020
To: 0 north Pine St Condo Association
From: Michael J Guida Sr-Plumbing&Gas Inspector
Re: Plumbing and Gas Violations
To whom it my concern,
This an official notice that the heating equipment at the above address are non-compliant to manufactures
recommendations.The gas heating equipment is on combustible flooring covered with a stone like material that
has been compromised allowing heat to radiate and could cause further damage.All gas heating boilers must be
brought to a minimum standard set by the manufacture of the equipment for clearances to combustible's and
confined spaces.
The work that needs to be done extensive and the removal and re-assembly of the gas heating equipment may not
be energy effective due to the age of the gas equipment, I recommend that new heating equipment should be
installed to prevent another potential loss of property or life.All work must be permitted/inspected by The City of
Salem Building Dept.
Best Regards
Michael J Guida Sr.
Plumbing and Gas Inspector
Cc:Building Commissioner
Cc: Salem Fire Dept-Fire Prevention
CITY OF SALEM, MASSACHUSETTS
A BUILDING DEPARTMENT
Vi=fy OFFICE OF THE PLUMBING AND GAS INSPECTOR
98 WASHINGTON STREET,2ND FLOOR
TEL. (978)745-9595 MAIN
KIMBERLEY DRISCOLL TEL. (978) 619-5639 DIRECT
MAYOR
TI IOMAs ST.PIERRE
DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER
Michael J Guida Sr.
Plumbing and Gas Inspector